SECTIONAL BODY
VALVES
Model S V
STANDARD FEATURES
• 1-10 Sections Per Valve Bank • Differential Poppet Style Relief, Adjustable
• Load Checks On Each Section from 1500 to 3000 psi (Also available in Low Pressure
• Hard Chrome Plated Spools Version Adjustable from 500 to 1500 psi)
• Compact Construction • Power Beyond Capability
• Enhanced Metering Section Available in • Reversible Handle
both the High and Low Sections • Mid-Inlet and Lock Valve Section available
• Flow Control Inlet
SPECIFICATIONS
Parallel or Series Circuit Construction Foot Mounting
Pressure Rating Maximum Operating Temp............................180°F
Maximum Operating Pressure......... 3000 psi Weight Per Section
Maximum Tank Pressure................... 500 psi Inlet Section..................................... Approx 3.75 Ibs
Nominal Flow Rating ............................12 GPM Outlet Section................................. Approx 3.75 Ibs.
Refer to Pressure Drop Curves. Work Section (Standard)................ Approx 5.50 Ibs.
Filtration: For general purpose valves, fluid Work Section (High) . ..................... Approx 8.00 Ibs.
cleanliness should meet the ISO 4406 19/17/14
level. For extended life or for pilot operated valves,
the 18/16/13 fluid cleanliness level is recommended.
CATV 18-09-04-01
V18 PRINCE MANUFACTURING CORPORATION • P.O. BOX 7000 • NORTH SIOUX CITY, SOUTH DAKOTA 57049-7000
URL: www.princehyd.com • E-MAIL: prince@princehyd.com
O.E.M. CUSTOMER SERVICE: (605) 235-1220 • FAX (712) 233-2181 DISTRIBUTOR CUSTOMER SERVICE: PHONE (605) 235-1220 • FAX (712) 233-2181
ordering information:
The following is a listing of valve sections available from stock on a standard basis.
standard sections available:
INLET SECTIONS ALL HAVE BOTH TOP AND SIDE INLET PORTS
PART NO. RELIEF TYPE AND SETTING PORT SIZE
SVI21 No Relief #10 SAE ORB (7/8-14 THD)
SVI24 Adjustable Low Pressure Relief Set at 1000 PSI #10 SAE ORB (7/8-14 THD)
SVI15 Adjustable High Pressure Relief Set At 2000 PSI #8 SAE ORB (3/4-16 THD)
SVI25 Adjustable High Pressure Relief Set at 2000 PSI #10 SAE ORB (7/8-14 THD)
WORK SECTIONS ALL HAVE #8 SAE ORB (3/4-16 THD) PORTS, LOAD CHECK AND STANDARD LEVER HANDLE
PART NO. SPOOL TYPE AND ACTION
SVW1AA1 3-Way Single Acting w/ Spring Center
SVW1BA1 4-Way Double Acting w/ Spring Center (Work Ports Blocked in Neutral)
SVW1BB1 4-Way Double Acting w/ 3 Position Detent (Work Ports Blocked in Neutral)
SVW1CA1 4-Way Motor Spool w/ Spring Center (Work Ports Open to Tank in Neutral
SVW1CB1 4-Way Motor Spool w/ 3 Position Detent (Work Ports Open to Tank in Neutral)
SVW1DD1 4-Way 4 Position Float w/ Spring Center and Float Detent
SVL1CA1 4-Way Spool w/ Spring Center (with Pilot Operated Checks on Both Work Ports)
SVM1ES1 4-Way Meter Spool w/ Spring Center (Work Ports Blocked in Neutral)
PORT RELIEF WORK SECTIONS ALL HAVE #8 SAE ORB (3/4-16 THD) PORTS, LOAD CHECK AND STANDARD LEVER
HANDLE. MODELS WITH RELIEF FACTORY SET AT 2000 PSI AT 3 GPM.
PART NO. SPOOL TYPE AND ACTION PORT RELIEFS
SVH1BA1AA 4-Way Double Acting w/ Spring Center Port Relief Plugged
SVH1BA1GG 4-Way Double Acting w/ Spring Center Adjustable 1500-3000 PSI
SVH1DD1AA 4-Way 4 Position Float w/ Spring Center and Float Detent Port Relief Plugged
SVH1DD1BB 4-Way 4 Position Float w/ Spring Center and Float Detent Shim Adjustable 1500-3000 PSI
SVR1ES1AA 4-Way Meter Spool w/ Spring Center Port Relief Plugged
SVR1ES1GG 4-Way Meter Spool w/ Spring Center Adjustable 1500-3000 PSI
SVS1GA1GG 4-Way Double Acting Series w/ Spring Center Adjustable 1500-3000 PSI
SVS1GA1AA 4-Way Double Acting Series w/ Spring Center Port Relief Plugged
OUTLET SECTIONS ALL HAVE BOTH TOP AND SIDE OUTLET PORTS
PART NO. EXHAUST OPTIONS PORT SIZE
SVE11 Open Center Outlet w/ Conversion Plug #8 SAE ORB (3/4-16 THD)
VALVES
SVE21 Open Center Outlet w/ Conversion Plug #10 SAE ORB (7/8-14 THD)
SVE22 Power Beyond Outlet w/ #8 SAE Beyond Port #10 SAE ORB (7/8-14 THD)
SVE23 Closed Center Outlet #10 SAE ORB (7/8-14 THD)
SVE26 Open Center Outlet Pressure Build-up Valve #10 SAE ORB (7/8-14 THD)
SVE27 Power Beyond Pressure Build-up Valve #10 SAE ORB (7/8-14 THD)
TIE ROD KITS PART NO. PART NO.
TIE ROD TORQUE 660401001 1 Section* 660401006 6 Sections*
150in-lbs ± 6in-lbs 660401002 2 Sections* 660401007 7 Sections*
660401003 3 Sections* 660401008 8 Sections*
(12 1/2 ft-lbs ±1/2)
660401004 4 Sections* 660401009 9 Sections*
660401005 5 Sections* 660401010 10 Sections*
*Number of Work Sections
special INLET AND OUTLET sections available: Sections other than standard models listed can be
made to order. Use order code Matrix below to generate a model number that meets your requirements. If you prefer, contact your Sales
Representative with your specific requirements and a model number will be assigned for you. This model number can be used for future
orders. A minimum order quantity will apply to special valves. Please consult Sales Representative.
All inlet sections have All outlet sections have
INLET SECTIONS top and side inlets. OUTLET SECTION top and side outlets.
SVIXX-XXXX SVEXX
RELIEF SETTING (in PSI) EXHAUST OPTION
1. Std. Open Center Outlet
PORT SIZE PORT SIZE w/Conversion Plug
RELIEF OPTION 1. #8 SAE ORB (3/4-16 THD)
1. #8 SAE ORB (3/4-16 THD) 1. No Relief Plug 2. Power Beyond Outlet
2. #10 SAE ORB (7/8-14 THD) 4. Adj. Low Pressure 500-1500 PSI 2. #10 SAE ORB (7/8-14 THD) w/#8 SAE Beyond Port
5. Adj. High Pressure 1500-3000 PSI 3. Closed Center Outlet 0
6. Plastic Plug in relief cavity. 6 Open Center Outlet Pressure
Use only when cartridge is to be in- Build-up
stalled at a later date. 7. Power Beyond Pressure Build-up
#8 SAE Beyond Port
0
Often used with no relief. Review application
valve assemblies
The Model SV sectional body directional control valve can be ordered as separate sections or as a complete factory tested assembly. This will need
to be specified with each order. An assembly number will be assigned at the time of the order. This assembly number can then be used for future
orders.
performance curves
PRESSURE (PSI)
200 5 2500
150 4 2000
3
100 2 1500
1
VALVES
50 1000
2 4 6 8 10 12 14 16 2 4 6 8 10 12 14 16
FLOW GPM FLOW GPM
25 25
2 4 6 8 10 12 14 16 2 4 6 8 10 12 14 16
FLOW GPM FLOW GPM
100 200 1
75 3 150
50 1 100
25 50
4 6 8 10 12 14 16 4 6 8 10 12 14 16
FLOW GPM 120 SUS OIL AT 100˚F FLOW GPM
CATV 21-09-04-01
PRINCE MANUFACTURING CORPORATION • P.O. BOX 7000 • NORTH SIOUX CITY, SOUTH DAKOTA 57049-7000
URL: www.princehyd.com • E-MAIL: prince@princehyd.com
V21
O.E.M. CUSTOMER SERVICE: (605) 235-1220 • FAX (712) 233-2181 DISTRIBUTOR CUSTOMER SERVICE: PHONE (605) 235-1220 • FAX (712) 233-2181
dimensional data
B WORK PORT work sections
A WORK PORT .25 TYP outlet cover
B WORK PORT
B WORK PORT A WORK PORT
A WORK PORT .25 .25
TYPTYP
A WORK PORT 1.50
B WORK PORT .25 TYP .75
1.501.50
1.09 .75 .75 1.50
PART NUMBER WILL 2.18 1.67 1.09 TOP OUTLET .75
1.091.09 CONVERSION PLUG
BE STAMPED IN THIS
1.091.09
PART
LOCATION
BE BE
NUMBER
TYPICAL
PART NUMBER
STAMPED
STAMPED
PART
WILL
WILL
IN THIS
IN THIS
NUMBER WILL
2.182.18 1.091.671.67
SPOOL
2.18 TRAVEL 1.67
SVW CONVERSION
PART NUMBER
WILL BE STAMPED
PLUG 1.94
PLUG
CONVERSION 1.09
TOPTOP
SIDE OUTLET
OUTLET
OUTLET
TOP OUTLET
CONVERSION PLUG
LOCATION
LOCATIONTYPICAL
TYPICAL
BE STAMPED IN THIS .250 TO WORK TYP.
SPOOL TRAVEL
.468 TO FLOAT TYP. TRAVEL
SPOOL SVW
SVW 1.44 PART NUMBER
IN THIS LOCATION
PART NUMBER 1.941.94 SIDE OUTLET
SIDE OUTLET
LOCATION TYPICAL
FLOAT OPTION
.250.250 SPOOL
TO TO
WORK TRAVEL
TYP.
WORK TYP. SVW .72
1.441.44
WILL BE BE
WILL
IN THIS
STAMPED
STAMPED
PART NUMBER
LOCATION
IN WILL
THIS LOCATION
BE STAMPED
1.94 SIDE OUTLET
FLOAT OPTION .250 TO WORK
FLOAT OPTION .468.468
TO TO
FLOAT TYP.
FLOAT TYP. TYP. 1.25 .72 .72 1.44 IN THIS LOCATION 3.25
FLOAT OPTION .468 TO FLOAT TYP. .72
SVEXX 2.00 3.253.25
2.91 1.251.25 3.25
1.25 SVEXX
SVEXX 2.00
2.00
2.912.91 SVEXX 2.00
1.55 2.91
1.551.55
1.50 5.34 1.75
1.55
1.501.50 5.345.34 1.751.75
inlet cover
1.50 1.63 1.88
5.34 SVH/SVR/ .721.44
1.75
1.631.63 1.881.88 SVH/SVR/
SVG SVH/SVR/ .721.441.44 1.50
1.63 1.88
SVGSVH/SVR/ .72 1.44 .75
SVG 3.00 .72 1.501.50
.75
SVG TOP INLET
.75
1.50
.75 1.09
SIDE INLET
.78
1.50 5.34 1.75 .78 .78
SPOOL TRAVEL .78
1.501.50 5.345.34 1.751.75
1.50
.281 TO WORK TYP.
5.34 SPOOL
SPOOLTRAVEL
TRAVEL 1.75 SVM/SVF Number of Work Sections “A” “B*”
2.50 1.50 TO WORK
.281.281 TOSPOOL
WORK TYP.
TRAVEL
TYP. SVM/SVF
SVM/SVF
1.44
1 2.875 5.875
1.22
2.502.50 .281
1.50 TO
1.50 WORK TYP. SVM/SVF
.72
1.441.44 2 4.312 7.312
2.50
1.221.22 1.50 .72 .72 1.44
1.22 1.40 3 5.750 8.750
.72
4 7.187 10.187
3.06 1.401.40 5 8.625 11.625
1.40
3.063.06 6 10.062 13.062
3.06 7 11.500 14.500
1.50 5.34 1.75 8 12.937 15.937
1.501.50 5.345.34 1.751.75 9 14.375 17.375
1.50 5.34 1.75 10 15.812 18.812
*With #10 plug in inlet & power beyond in outlet.
CATV 22-09-04-01
V22 PRINCE MANUFACTURING CORPORATION • P.O. BOX 7000 • NORTH SIOUX CITY, SOUTH DAKOTA 57049-7000
URL: www.princehyd.com • E-MAIL: prince@princehyd.com
O.E.M. CUSTOMER SERVICE: (605) 235-1220 • FAX (712) 233-2181 DISTRIBUTOR CUSTOMER SERVICE: PHONE (605) 235-1220 • FAX (712) 233-2181
typical stack dimensional data
12.50
7.44 12.50 5.58
7.44 5.58
2.00 SVEXX
2.00
2.00 SVEXX
2.00
C-590
C-590
9.30
2.60 9.30
1.95 2.60 1.75
1.95 8.59 1.75
8.59 POWER BEYOND PORT
POWER
3.71 BEYOND PORT
3.71
SIDE OUTLET
SIDE OUTLET
TOP OUTLET
TOP OUTLET
SVE
1.47
SVE
1.47
SVL
1.44 SVL
THE ROD TORQUE 1.44
SVH\SVS
150 in-lbs +6 in - lbs 1.44
SVH\SVS
(12 1/2 ft - lbs +1/2 1.44
SVM
SVM
SVW
SVW
-S12L
-S12L
-T12Q
1.47 -T12Q
1.47
SVI
SVI
VALVES
3.86
3.86
3.88
3.06 3.88
3.06
7.66
7.66
5.88
5.88
5.00
5.00
C-635 SVIXX
C-635 SVIXX
SVIXX SVIXX
SVIXX SVIXX
Handle option 11 (SVW & SVM) Handle option 12 (SVH, SVL, SVS & SVR)
Handle option 11 (SVW & SVM) Handle option 12 (SVH, SVL, SVS & SVR)
CATV 23-09-04-01
PRINCE MANUFACTURING CORPORATION • P.O. BOX 7000 • NORTH SIOUX CITY, SOUTH DAKOTA 57049-7000
URL: www.princehyd.com • E-MAIL: prince@princehyd.com
V23
O.E.M. CUSTOMER SERVICE: (605) 235-1220 • FAX (712) 233-2181 DISTRIBUTOR CUSTOMER SERVICE: PHONE (605) 235-1220 • FAX (712) 233-2181
parallel circuit svw, svm, SVF, svh, svr, SVG and svl work sections
OPEN CENTER PASSAGE
Parallel circuit sections are by far the most common. The SVW, SVM, SVF, OPEN
OPENCENTER
CENTERPASSAGE
PASSAGE
SVH, SVR, SVG and SVL are all of parallel circuit construction. They can LOAD CHECK
LOAD
LOADCHECK
be combined together in any order in an assembly. When any one of the PARALLEL
CHECK CIRCUIT CORE
PARALLEL CIRCUIT CORE
spools is shifted, it blocks off the open center passage through the valve. B B PARALLEL CIRCUIT
B CORE
The oil then flows into the parallel circuit core making oil available to all BB BB BB
spools. If more than one spool is fully shifted, the oil will go to the spool with
the lowest pressure requirements. However, it is possible to meter the flow
to the spool with the lease load and provide flow to two unequal loads.
ENHANCED METERING SECTIONS P
The SVM, SVF, SVR and SVG sections have metering notches machined PP
into the spool to allow for better “feathering” of a load. The spool travel for
these sections is also a little longer at .281” vs. .250” for the standard
sections. In addition to the metering notches in the spool, the lands in the
SVF and SVG bodies have been machined to give more precise control A A A T
over the flow. The metering notches in the SVF and SVG have been AA AA AA TT
optimized for flows of 10 gpm or less. For enhanced metering on higher CONVERSION PLUG
flows, it is recommended that the SVM or SVR be used. CONVERSION
CONVERSIONPLUG
PLUG
LOCK SECTIONS
The SVL section combines both a 4-way directional valve and a double pilot operated check valve. This provides very
low leakage when the spool is in neutral. When the spool is shifted, oil is directed through a work port check to the
cylinder. Pressure on the work port applies pressure to the shuttle spool, opening the opposite check valve and allowing
oil to return into the valve. Depending on load pressures, the metering of the spool may be affected. In some cases a
one way restrictor in a work port may be beneficial.
230009009
230009009 4 WAY 3 POSITION
4 WAY 3 POSITION
670700034 OPTION B
670700034 OPTIONOPTION
670700033 B C
670700033 OPTION C TANK CORE A LOAD CHECK IS STANDARD ON EACH WORK SECTION
TANK CORE A LOAD CHECK IS STANDARD ON EACH WORK SECTION
PARALLEL POWER CORE
PARALLEL POWER CORE
SHUTTLE SPOOL LOCK VALVE
SHUTTLE SPOOL LOCK VALVE
SPOOL ATTACHMENT OPTION A CARTRIDGE
SPOOL ATTACHMENT OPTION A 660180001) CARTRIDGE
SPRING CENTER (KIT NO.
SPRING CENTER (KIT NO. 660180001)
671400033 OPTION C
671400033 OPTIONDOUBLE
C ACTING WORK
671400037 DOUBLEPORTS
ACTING WORK
OPEN IN NEUTRAL
671400037 PORTS OPEN IN NEUTRAL
671400036 SVL
671400036 SVL
671900010
671900010
4 WAY 3 POSITION
4 WAY 3MOTOR
POSITION
670300030 MOTOR
670300030
VALVES
170003008
170003008 OPEN CENTER CORES
670500044 OPEN CENTER CORES
670500044
POWER CORES LOAD CHECK
POWER CORES LOAD CHECK
ADJUSTABLE
ADJUSTABLE
DIRECT ACTING ANTI-CAVITATION
DIRECTRELIEF
ACTINGOPTION 'G' ANTI-CAVITATION
CHECK OPTION 'D'
RELIEF OPTION 'G' CHECK OPTION 'D' ADJUSTABLE HANDLE
SPOOL ATTACHMENT OPTION D ADJUSTABLE HANDLE
OPTION 4
SPOOL ATTACHMENT
SPRING CENTER OPTION D DETENT
W/FLOAT OPTION 4
SPRING(KIT
CENTER W/FLOAT DETENT
NO. 660180051)
(KIT NO. 660180051) 670700037
670700037
670500048
670500048
670100009
SVH SVH
670100009
230009009
230009009
670700036 OPTION D
670700036 OPTION4DWAY DOUBLE ACTING
170003027 4 WAY DOUBLE
WITH 4thACTING
POSITION FLOAT
170003027 WITH 4th POSITION FLOAT
670500043
670500043 670300032
670300032 670300031
670300031 671200007
671200007
SV WORK PORT RELIEF
SV WORK PORT RELIEFS, OPTION B, C, G, & PR - O -
PR - O -
H CAN BE ORDERED PRETESTED. USE
ORDER CODE AT RIGHT MODEL NUMBER
MODEL NUMBER
PORT SIZE
PORT SIZE
RELIEF TYPE
RELIEF TYPE
PRESSURE SETTING
PRESSURE SETTING
0 H- ADJUSTABLE SPECIFY RELIEF
0 CARTRIDGE H- ADJUSTABLE
1500-3000 PSI SPECIFY RELIEF
PRESSURE.
CARTRIDGEONLY 1500-3000 PSI PRESSURE.
LEAVE BLANK FOR
ONLY L- ADJUSTABLE LEAVE BLANK FOR
L- ADJUSTABLE STANDARD
500-1500 PSI STANDARD SETTINGS.
500-1500 PSI SETTINGS.
NH- NON-ADJUSTABLE
NH- NON-ADJUSTABLE STANDARD SETTING:
1500-3000 PSISTANDARD
1500-3000 PSI
NL- NON-ADJUSTABLE 2000SETTING:
PSI for H and NH
NL- NON-ADJUSTABLE 2000 PSI for HPSI
andfor
NHL and NL
500-1500 PSI 1000 PSI1000
for L and NL
500-1500 PSI
CATV 25-09-04-01
PRINCE MANUFACTURING CORPORATION • P.O. BOX 7000 • NORTH SIOUX CITY, SOUTH DAKOTA 57049-7000
URL: www.princehyd.com • E-MAIL: prince@princehyd.com
V25
O.E.M. CUSTOMER SERVICE: (605) 235-1220 • FAX (712) 233-2181 DISTRIBUTOR CUSTOMER SERVICE: PHONE (605) 235-1220 • FAX (712) 233-2181
sv inlet relief options
OPTION 1 NO RELIEF
TOP INLET This option provides no built in relief. This is used when a relief is
TOP INLET
provided elsewhere in the system or in a closed center application.
This plug can be replaced with a relief cartridge at a later date.
SVIXX
OPTION 5 HIGH PRESSURE ADJUSTABLE
SVIXX RELIEF
This option provides for a differential poppet relief adjustable from
SIDE INLET 1500-3000 PSI. Set at 2000 PSI @ 10 GPM. The differential poppet
SIDE INLET
relief provides smooth quiet operation with high cracking pressure.
RELIEF CARTRIDGES
SVIXX CAN BE ORDERED PRETESTED SEE RV-OX RELIEF, PAGE V65.
in the field for power beyond or closed This option directs oil from open center core thru pressure
center applications. When spools are in build-up valve and then to tank. See solenoid section for
neutral the inlet is unloaded to tank. 1.38 description of operation.
1.00
1.00 OPTION 2 POWER BEYOND OUTLET 2.00 OPTION 7 POWER BEYOND PRESSURE BUILD-UP
WITH #8 SAE BEYOND PORT 2.00 VALVE FOR SOLENOID OPTION
This option provides for a high pressure This option directs oil from inlet thru pressure build-up valve
power beyond port. This would be used and then downstream. This pressure build-up valve provides
if a valve is to be added down stream. a #8 SAE power beyond port. The outlet must be connected
1.00 THE OUTLET PORT MUST STILL BE
2.00 to tank.
CONNECTED TO TANK. When spools
are in neutral the inlet is connected to
the power beyond port.
sv mid-inlet section
MID INLET PORT POWER CORE BLOCKING
MID INLET PORT POWER CORE BLOCKING
PLATE INSTALLS IN
MID INLET RELIEF PLATE
POWER INSTALLS INSVIM
CORE BETWEEN 1XX-XXXX
MID INLET RELIEF POWER CORE BETWEEN
MID INLET & UPSTREAM Last Four Digits Specify
MID INLET & UPSTREAM
SECTION.
SECTION. A Non-Standard Relief Pressure.
When blank, refer to standard setting
MID INLET PORT POWER CORE BLOCKING 1-No Relief
PLATE INSTALLS IN 2-SHIM Adjustable 500-1500 PSI Std. Setting 1000 PSI @ 10GPM
MID INLET RELIEF POWER CORE BETWEEN
MID INLET & UPSTREAM 3-SHIM Adjustable 1500-3000 PSI Std. Setting 2000 PSI @ 10 GPM
SECTION. 4-Adjustable 500-1500 PSI Std. Setting 1000 PSI @ 10 GPM
5-Adjustable 1500-3000 PSI Std. Setting 2000 PSI @ 10 GPM
C-Combined Flow Mid-Inlet
S-Split Flow Mid-Inlet (not available after a series section)
See Section View at left. Note
Location of Spacer, Part Number 671200035
SPACER
SPACER 1. Port Size #8 SAE ORB (3/4-16 THD)
SPLIT MID-INLET SHOWN CAN BE CONVERTED TO COMBINED DESCRIPTION:
SPLIT MID-INLET
MID-INLET SHOWNSPACER
BY MOVING CAN BETO
CONVERTED
OPPOSITE TO
ENDCOMBINED
MID-INLET BY MOVING SPACER TO OPPOSITE END A Mid-Inlet provides an inlet port for a second pump mid stream in the valve stack. A
relief can be provided in this section. With the combined flow the flow from both pumps is
SPACER available to the downstream sections when all the work sections upstream are in neutral.
The split flow completely separates the two pump flows. The common tank passage is all
SPLIT MID-INLET SHOWN CAN BE CONVERTED TO COMBINED that is shared between the two pump flows. Note: Split flow mid inlet is not available when
MID-INLET BY MOVING SPACER TO OPPOSITE END used after a series section and the core block plate is not used after a series section.
CATV 26-09-04-01
V26 PRINCE MANUFACTURING CORPORATION • P.O. BOX 7000 • NORTH SIOUX CITY, SOUTH DAKOTA 57049-7000
URL: www.princehyd.com • E-MAIL: prince@princehyd.com
O.E.M. CUSTOMER SERVICE: (605) 235-1220 • FAX (712) 233-2181 DISTRIBUTOR CUSTOMER SERVICE: PHONE (605) 235-1220 • FAX (712) 233-2181
sv flow control inlet section
SVIFXXXXXX The SVIF Flow Control Inlet is
interchangeable with the standard SV
PORT SIZE SOLENOID OPTION inlet section.
1- Side and End Inlet #10 SAE ORB Omit for Flow Control Option M
2- Side and End Inlet #10 SAE 12Q-12VDC Double Spade Coil FLOW CONTROL OPTIONS:
ORB, with #8 SAE ORB External 24Q-24VDC Double Spade Coil P OPTION incorporates a solenoid
EF Circuit 12H-12VDC DIN 43650 Coil operated, electrically variable pressure-
24H - 24VDC DIN 43650 Coil compensated flow control cartridge.
RELIEF VALVE With the solenoid de-energized, all
12L-12VDC Double Lead Wire Coil
1- No Relief of the inlet flow is diverted to the tank
24L - 24VDC Double Lead Wire Coil
2- Direct acting non-adjustable core/EF port. By increasing the current
12W -12VDC Double Lead Wire w/ Weatherpak
500-1500 psi set at 1000 psi* through the solenoid, the flow directed
Connector Coil
3- Direct acting non-adjustable to the power core and downstream
24W - 24VDC Double Lead Wire w/ Weatherpak
1500-3000 psi set at 2000 psi* sections will be proportionally
Connector Coil
4- Direct acting adjustable 500-1500 psi increased, (the maximum rating of
set at 1000 psi* FLOW CONTROL OPTION the cartridge is 16 gpm at 1500 mA)
5- Direct acting adjustable 1500-3000 psi M- Manual Flow Control Control current is normally provided
set at 2000 psi* P- Electro-Proportional via a controller card providing, a PWM
*for other settings please specify, i.e. U- Solenoid Unloading signal.
SVInlet
#10 Rear IF15P12Q-2700
Port #10 is setInlet
Rear at 2700
Port psi #10 Side Inlet Port #10 Side Inlet Port
U OPTION incorporates a solenoid
#10 Rear Inlet Port #10 Side Inlet Port operated, unloader cartridge. With the
solenoid de-energized, all of the inlet
IN IN flow is diverted to the tank core/EF
port. With the solenoid energized all
IN the inlet flow is directed to the power
core and downstream sections.
Option P- Proportional flow Option P- Proportional
M OPTION flow incorporates a manually
C-760 C-760
control with manual overridecontrol with manual
operatedoverride
pressure-compensated flow
EF SVIFXXX-XX EF SVIFXXX-XX Option P- Proportional flow control cartridge. With the control knob
C-760 control with manual
5.18override turned fully in (clockwise), all of the
5.18 inlet flow is diverted to the tank core/
EF SVIFXXX-XX
EF port. By turning the flow control
5.18
knob counter clockwise, the inlet
2.00 2.00 Optional #8 EF Port
Optional #8 EF Port flow directed to the power core and
VALVES
downstream sections is proportionally
2.00 Optional #8 EF Port increased. Approximately 5 revolutions
varies flow from no flow to full flow,
SOL Output
Power Input
RED+ BLACK-
SOL Output
Power Input
*With the power off, the inlet flow is directed to the tank (or excess flow
-Black -Black OFF
Power
OK
(4.63)
ON
Power Switch (4.63)
Prince Manufacturing
Corporation
Power
OK
0
0 1
port).
1
RED+ BLACK-
10
SOL Output
2
Power Input
10
2
(5.75)
9
3
*To provide power to the control, move the power switch to ON. (Green
-Black (4.63) (5.75)
9
3
Power
8
4
OK
+Red
8
4
5 7
+Red
0
(5.00)
2
*Minimum flow is directed into the valve when 0 on the dial is aligned with (5.00) (5.75)
9
3
8
4
the center mark. Maximum flow is directed into the valve when+Red 10 on the
5 7
6
SEE DETAIL
SEEOFFSET
DETAIL AT AT LEFT
LEFT
HANDLE SHOWN
SEE DETAIL AT LEFT
HANDLE LEFT 6th SPOOL INHANDLE
HANDLE BACKBACK 5th SPOOL
5th SPOOL OUT OUT
HANDLE RIGHT 6th SPOOL OUT
HANDLE BACK 5th SPOOL OUT
Please refer to these part numbers and state which sections the
handle is to be installed on when ordering a valve assembly. This
handle can be installed in the field to work sections with handle
option 3 (no handle).
JOYSTICK ASSEMBLY W/STRAIGHT HANDLE:
ASSEMBLED ON VALVE............................ SVJS
KIT..................................................... 660180017
VALVES
ONE WAY WORK PORT RESTRICTOR FOR ONE WAY WORK PORT RESTRICTOR FOR SVW WORK
SVH, SVM, SVR, & SVL WORK SECTIONS SECTIONS
This restrictor will restrict oil in one direction and This restrictor will restrict oil in one direction and allow free
allow free flow in the opposite direction. This flow in the opposite direction. This restrictor consists of the
restrictor consists of an orifice plate that simply orifice plate as described at left and an adapter fitting that
drops into the #8 SAE work port of a SVH, SVM, allow use in the standard SVW #8 SAE work port.
SVR, & SVL work section.
Restricted Free Restricted Free
Flow Flow Flow Flow
Restricted
Restricted Free Free Restricted
Restricted Free Free
Flow Flow Restricted Flow Flow Free Flow Flow Restricted Flow Flow Free
Flow Flow Flow Flow
SV SOLENOID OPERATED
Work Sections
• Type “-T” Solenoid Operated
• Type “-S” Solenoid and Manual Operation
VALVES
STANDARD FEATURES
SPECIFICATIONS
Parallel or Series Circuit Construction Foot Mounting
Pressure Rating Maximum Operating Temp.................180°F
Maximum Operating Pressure................ 3000 psi Weight Per Section
Maximum Tank Pressure.......................... 150 psi Inlet Section........................ Approx. 3.75 Ibs.
Nominal Flow Rating ............................12 GPM Outlet Section..................... Approx. 3.75 Ibs.
Differential Pressure Solenoid Operated
Required to Actuator . ............Approx. 150 PSI Type “-T” Work Section........Approx. 11.0 Ibs.
Filtration: For general purpose valves, fluid Type “-S” Work Section............. Approx. 14.5 Ibs.
cleanliness should meet the ISO 4406 19/17/14
level. For extended life or for pilot operated valves,
the 18/16/13 fluid cleanliness level is recommended.
CATV 29-09-04-01
PRINCE MANUFACTURING CORPORATION • P.O. BOX 7000 • NORTH SIOUX CITY, SOUTH DAKOTA 57049-7000
URL: www.princehyd.com • E-MAIL: prince@princehyd.com
V29
O.E.M. CUSTOMER SERVICE: (712) 233-2181 • FAX (605) 235-1082 DISTRIBUTOR CUSTOMER SERVICE: PHONE (605) 235-1220 • FAX (712) 233-2181
TYPE “-T” SOLENOID DESCRIPTION OF OPERATION
The Type “-T” Solenoid Operated SV Work Section allows remote electrical on-off control. This solenoid operated SV
section may be assembled with other standard SV manual sections, or type “-S” solenoid and manual sections.
The Type “-T” Solenoid Operated SV Section contains two 3-way 2-position solenoid cartridge valves, one at each
end of the main valve body. When both solenoids are de-energized, both ends of the control valve spool are open to
tank pressure and the spool remains spring centered. When solenoid “A” is energized, pilot pressure is applied to one
end of the control valve spool causing the spool to shift from neutral to full stroke on “A” work port. When solenoid “B”
is energized, pilot pressure is applied to the other end of the control valve spool causing the spool to shift to full stroke
on “B” work port.
Internal pilot lines provide pilot pressure to the solenoid actuators. Pilot pressure is generated by a “Pressure Build-Up
Valve” that is installed in the standard outlet section. Two versions of the pressure build-up valve are offered. The open
center pressure build-up valve and the power beyond pressure build-up valve. Both versions supply 150-200 PSI pilot
pressure to the solenoid actuators.
APPLICATION INFORMATION
For over center or light load applications if the required work port load pressure drops below 200 PSI, the pilot pressure
to the spool will drop to the same pressure causing the spring to move the control spool back towards the neutral position.
The spool will end up in an intermediate position between neutral and fully shifted. A restrictor installed in the work
port or line may be required for this type of application.
For closed center applications the Pressure Build-Up Valve is not required. However, a system pressure of 200 PSI
must be maintained in the closed center position to actuate the valve properly.
Proper operation of the solenoid actuators requires a pressure differential of 150-200 PSI above tank pressure. The
maximum tank port pressure should not exceed 150 PSI. Excessive tank pressure will increase “Seal Drag” and
may prohibit, the spool from shifting.
The solenoid operated SV section may be converted to accept an external hydraulic pilot supply to the solenoid actuators.
Please consult a Sales Representative for information.
SOLENOID OPERATED
SVH
WORK SECTIONS ALL HAVE #8 SAE PORTS AND LOAD CHECK. MODELS WITH RELIEF, FACTORY SET AT 2000 PSI AT 3 GPM
PART NO. SPOOL TYPE/VOLTAGE PORT RELIEFS
SVH1BAGG-T12Q 4 WAY-3 POSITION/12 VDC ADJUSTABLE 1500-3000 PSI
SVH1BAAA-T12Q 4 WAY-3 POSITION/12 VDC PORT RELIEF PLUGGED
SVH1CAGG-T12Q 4 WAY-3 POSITION MOTOR/12 VDC ADJUSTABLE 1500 - 3000 PSI
SPECIAL SECTIONS AVAILABLE: Sections other than the standard models listed can be made to order. Use the order
code Matrix below to generate a model number that meets your requirements. If you
prefer, contact your Sales Representative with your specific requirements and a model
number will be assigned for you. This model number can then be used for future
orders. A minimum order quantity will apply to special valves. Please contact your
Sales Representative.
SOLENOID OPERATED
PORT RELIEF WORK SECTION
SVH XXXXX—TXXX
SECTION TYPE COIL VOLTAGE & TERMINATION *
H-Port Relief Section 12Q, 12 VDC Double Spade
S-Series Section (Use G spool) 12L, 12 VDC Double Wire
12H, 12 VDC DIN 43650
VALVES
PORT SIZE 12W, 12 VDC Weather Pack ®
1. #8 SAE 24Q, 24 VDC Double Spade
24L, 24 VDC Double Wire
SPOOL TYPE 24H, 24 VDC DIN 43650
A-3-Way 3-Position 11C, 120 VAC Conduit
B-4-Way 3-Position 11H, 120 VAC DIN 43650
C-4-Way 3-Position Motor
G-4-Way Series
SPOOL ACTIONS SOLENOID OPERATION
A - Spring Center
SOLENOID OPERATED
SVW AND SVL WORK SECTIONS
SVWXXX—TXXX
SECTION TYPE
W-Standard Work Section
L-Lock Section (Use C Spool)
COIL VOLTAGE & TERMINATION *
12Q, 12 VDC Double Spade
12L, 12 VDC Double Wire
PORT SIZE 12H, 12 VDC DIN 43650
1. #8 SAE 12W, 12 VDC Weather Pack ®
24Q, 24 VDC Double Spade
SPOOL TYPE 24 L, 24 VDC Double Wire
A-3-Way 3-Position 24H, 24 VDC DIN 43650
B-4-Way 3-Position 11C, 120 VAC Conduit
C-4-Way 3-Position Motor
11H, 120 VAC Din 43650
SPOOL ACTIONS
A - Spring Center SOLENOID OPERATION
* See page V34 for coil details
CATV 31-09-04-01
PRINCE MANUFACTURING CORPORATION • P.O. BOX 7000 • NORTH SIOUX CITY, SOUTH DAKOTA 57049-7000
URL: www.princehyd.com • E-MAIL: prince@princehyd.com
V31
O.E.M. CUSTOMER SERVICE: (605) 235-1220 • FAX (712) 233-2181 DISTRIBUTOR CUSTOMER SERVICE: PHONE (605) 235-1220 • FAX (712) 233-2181
SEE PAGE 15 & 16 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING
ordering information: “-S” SOLENOID AND MANUAL WORK SECTIONS
The following is a listing of valve sections available from stock on a standard basis.
standard sections available:
SOLENOID
OPERATED SVW WORK SECTIONS ALL HAVE #8 SAE PORTS, LOAD CHECK AND STANDARD LEVER HANDLE
PART NO. SPOOL TYPE/VOLTAGE
SVW1AA1-S12Q 3 WAY-3 POSITION/12 VDC For Inlets, Outlets and
SVW1BA1-S12Q 4 WAY-3 POSITION/12 VDC Tie-rod Kits, please refer
SVW1CA1-S12Q 4 WAY-3 POSITION MOTOR/12 VDC to SV Section
SVW1BA1-S24Q 4 WAY-3 POSITION/24 VDC
SOLENOID OPERATED SVH WORK SECTIONS ALL HAVE #8 SAE PORTS, LOAD CHECK AND STANDARD LEVER HANDLE
MODELS WITH RELIEF, FACTORY SET AT 2000 PSI AT 3 GPM
PART NO. SPOOL TYPE/VOLTAGE PORT RELIEFS
SVH1BA1AA-S12Q 4 WAY DOUBLE ACTING/12 VDC PORT RELIEF PLUGGED
SVH1BA1AA-S24Q 4 WAY DOUBLE ACTING/24 VDC PORT RELIEF PLUGGED
SVH1BA1BB-S12Q 4 WAY DOUBLE ACTING/12 VDC SHIM ADJ. 1500-3000 PSI
SVH1BA1BB-S24Q 4 WAY DOUBLE ACTING/24 VDC SHIM ADJ. 1500-3000 PSI
SPECIAL SECTIONS AVAILABLE: Sections other than the standard models listed can be made to order. Use the order
code Matrix below to generate a model number that meets your requirements. If
you prefer, contact your Sales Representative with your specific requirements and
a model number will be assigned for you. This model number can then be used for
future orders. A minimum order quantity will apply to special valves. Please contact
your Sales Representative.
SOLENOID OPERATED
SVW AND SVL SECTION SVWXXXX–SXXX
SECTION TYPE
W-Standard Work Section COIL VOLTAGE & TERMINATION *
L-Lock Section (Use C Spool) 12Q, 12 VDC Double Spade
12L, 12 VDC Double Wire
PORT SIZE 12H, 12 VDC DIN 43650
1. #8 SAE
VALVES
5.89
5.89
C-635
C-635
3.50 5.344
3.50 5.344 1.44
12.34 1.44
12.34
A WORK PORT
B WORK PORT A WORK PORT
B WORK PORT
VALVES
TYPE “-T” SEAL KIT
660580014
LOAD CHECK
INTERNAL PILOT LINES SOLENOID CARTRIDGES
INTERNAL PILOT LINES
RESTRICTOR ORIFICE LOAD CHECK SEAL KIT
RESTRICTOR ORIFICE 660590008
NOTE: THIS OPTION CANNOT
BE ADDED IN THE FIELD.
NOTE: For additional data on inlet and outlet sections, valve assemblies, etc. Please refer SV information in this catalog.
SYMBOL
EXAMPLE TWO
SECTION STACK
SOL B SOL B
SOL B SOL B
B B
B B
A A
A A
SOL A SOL A
SOL A SOL A
NOTE: For additional dimensional data on inlet and outlet sections, valve assemblies, etc. please refer SV information in this catalog.
RECEIVING REQUEST.
NUMBER. ASSIGNED UPON
VALVE ASSEMBLY MODEL
P.O. BOX 7000 QUOTATION REQUEST FORM
N. SIOUX CITY, SD 57049-7000
PHONE (605) 235-1220
FAX (605) 235-1082 DATE_______________________________
SUBMITTED BY_ _____________________
CUSTOMER_ ________________________
ADDRESS___________________________
___________________________________
___________________________________
PHONE_____________________________
FAX________________________________
YEARLY REQUIREMENTS______________
CURRENT SUPPLIER_ ________________
FILL IN THE CHART BELOW USING ORDER CODE FROM SERIES 20 OR MODEL SV SECTION
NOTE ANY PORT RESTRICTORS, JOYSTICKS HANDLES, ETC. IN SPACE PROVIDED
ITEM SECTION NUMBER SECTION NOTES LIST
INLET
SECTION RELIEF: PSI @ GPM
WORK
SECTION 1 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
WORK
SECTION 2 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
VALVES
WORK
SECTION 3 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
WORK
SECTION 4 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
WORK
SECTION 5 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
WORK
SECTION 6 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
WORK
SECTION 7 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
WORK
SECTION 8 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
WORK
SECTION 9 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
WORK
SECTION 10 A RELIEF: PSI @ GPM B RELIEF: PSI @ GPM
OUTLET
SECTION
TIE ROD KIT
SPECIAL INSTRUCTIONS ASSEMBLY CHARGE (SV ONLY)
TOTAL
CATV 35-09-04-01
PRINCE MANUFACTURING CORPORATION • P.O. BOX 7000 • NORTH SIOUX CITY, SOUTH DAKOTA 57049-7000
URL: www.princehyd.com • E-MAIL: prince@princehyd.com
V35
O.E.M. CUSTOMER SERVICE: (605) 235-1220 • FAX (712) 233-2181 DISTRIBUTOR CUSTOMER SERVICE: PHONE (605) 235-1220 • FAX (712) 233-2181