Вы находитесь на странице: 1из 10

VOLUMEN 02: ANTEPROYECTO PARA EJECUCIN DE OBRAS

VOLUMEN 2A: INGENIERA BSICA PARA INVERSIN


SISTEMA ELCTRICO RURAL CRUCERO III ETAPA
RESUMEN EJECUTIVO
NDICE
1.

OBJETIVOS

2.

ANTECEDENTES

3.

UBICACIN GEOGRFICA

4.

RESUMEN ESTUDIO DE MERCADO

4.1
4.2

ANALISIS DE LA OFERTA
BALANCE OFERTA DEMANDA

5.

ALCANCES DEL PROYECTO

5.1
5.2

DE LAS LNEAS PRIMARIAS


DE LAS REDES DE DISTRIBUCIN

6.

DESCRIPCIN DEL PROYECTO

6.1
6.2
6.3

LNEAS Y REDES PRIMARIAS


SUBESTACIONES DE DISTRIBUCIN
REDES SECUNDARIAS

7.

PRESUPUESTO DE OBRA

8.

PLAZO DE EJECUCION

P033272

RE A LI ZAC I N DE E S TUD I OS PA R A E L DE S AR R OLLO DE


PR OY E C TOS D E E LE C TR I FIC A CI N RU RA L, FU E R A DE L R E A
DE C ON CE S I N D E LA S E MPR E S AS D IS TRI B UI D ORA S DE
EN ER G A E LC TRI C A, A NI V E L N AC I ON A L GR UP O I

SISTEMA ELCTRICO RURAL CRUCERO III ETAPA

VOLUMEN 02: ANTEPROYECTO PARA EJECUCIN DE OBRAS


VOLUMEN 2A: ANEXOS DEL ANTEPROYECTO

RESUMEN EJECUTIVO
1.

OBJETIVOS
El objetivo central del proyecto SER CRUCERO III ETAPA, es que los pobladores de las
localidades en el rea de influencia del proyecto cuenten con el servicio de energa elctrica
en forma continua y confiable, ofreciendo as nuevas oportunidades de desarrollo a la zona
del proyecto.
El objetivo del presente documento Anteproyecto de Expediente Tcnico es el de delimitar
los alcances de las actividades a ser desarrolladas por el Contratista que implementar la
obra, siendo stas, en resumen las siguientes:
- Elaboracin del Estudio Definitivo, Replanteo Topogrfico, Ubicacin de Estructuras e
Ingeniera Constructiva del proyecto tomando como referencia el presente documento.
- Transporte de Equipos y Materiales requeridos para la implementacin del proyecto
- Suministro de Equipos y Materiales requeridos para la implementacin del proyecto
Obras Civiles y Montaje Electromecnico para la implementacin del proyecto.
Las instalaciones que se implementarn con el presente proyecto permitirn el desarrollo
socio -econmico y agroindustrial de la zona del proyecto beneficiando a 4 698 habitantes y
1 077 abonados totales.

2.

ANTECEDENTES
El Sistema Elctrico Rural CRUCERO III, cuenta como unidad formuladora y ejecutora a la
Direccin General de Electrificacin Rural Ministerio de Energa y Minas.
Mediante Decreto supremo N 026-2007-EM de fecha 05 de Mayo del 2007, se cre la
Direccin General de Electrificacin Rural, y fusin del Proyecto de Mejoramiento de la
Electrificacin Rural, mediante la aplicacin de Fondos Concursables, Proyecto FONER y
de la Direccin Ejecutiva de Proyectos DEP del Ministerio de Energa y Minas.
Posteriormente mediante Resolucin Ministerial N 595-2007-MEM/DM de fecha 28 de
diciembre del 2007, se delega las funciones a la Direccin General de Electrificacin Rural
como Unidad Formuladora y Ejecutora.
El Ministerio de Energa y Minas a travs de la Direccin General de Electrificacin Rural
(MEM/DGER), tiene a su cargo la ejecucin del Plan Nacional de Electrificacin, y dentro de
ste, los proyectos de Generacin, Transmisin y Distribucin, con financiamiento
proveniente de distintas fuentes nacionales e internacionales.
El Sistema Elctrico Rural CRUCERO III forma parte del grupo de proyectos a ser
financiados por la Direccin General de Electrificacin Rural del Ministerio de Energa y
Minas.
La Empresa Hidrandina S.A., convoc a un Concurso Pblico N 012 2010, para contratar
los servicios a una empresa de consultora especializada, la que se encargue del desarrollo
de la Elaboracin de Estudios para el Desarrollo de Proyectos de Electrificacin Rural,

P033272

RE A LI ZAC I N DE E S TUD I OS PA R A E L DE S AR R OLLO DE


PR OY E C TOS D E E LE C TR I FIC A CI N RU RA L, FU E R A DE L R E A
DE C ON CE S I N D E LA S E MPR E S AS D IS TRI B UI D ORA S DE
EN ER G A E LC TRI C A, A NI V E L N AC I ON A L GR UP O I

Fuera del rea de Concesin de las Empresas Distribuidoras de Energa Elctrica, a Nivel
Nacional.
Luego del proceso de evaluacin, el Consorcio DESSAU SERING gana la buena pro e
inicia el desarrollo del servicio de consultora.
La Direccin General de Electrificacin Rural ha previsto electrificar, mediante conformacin
de Sistemas Elctricos Rurales, con energa proveniente del Sistema Elctrico
Interconectado Nacional (SEIN), a localidades ubicadas en las provincias respectivas de los
departamentos de Puno, Apurmac, Arequipa, Tacna, Madre de Dios y Cusco.
Con el objeto de satisfacer la demanda elctrica en la zona del proyecto, se ha previsto la
implementacin del Proyecto Sistema Elctrico Rural CRUCERO III, estableciendo entre
sus principales metas el incremento de la cobertura del servicio elctrico a la poblacin no
atendida y la mejora tcnica y econmica de los sistemas elctricos existentes que brindan
deficiente servicio y no permiten el desarrollo de las actividades productivas;
constituyndose como programa de carcter social.

3.

UBICACIN GEOGRFICA
El SER CRUCERO III Etapa se ubica en el departamento de Puno, en las provincias de
Carabaya, Melgar, Azngaro y Sandia; entre las coordenadas UTM-WGS84: 19 L 316000 E
y 8468000 N hasta 436000 E hasta 8380000 N; de la carta del Instituto Geogrfico Nacional,
el SER se desarrolla en la regin sierra

4.

RESUMEN ESTUDIO DE MERCADO


1.1

ANALISIS DE LA OFERTA

Electro Puno S.A.A, Empresa Regional de Servicio Pblico de Electricidad, es la empresa


concesionaria de la distribucin y comercializacin de energa elctrica en el Departamento
de Puno; y tiene su sede en la Ciudad de Puno.
El S.E.R CRUCERO III ETAPA tomar energa de los alimentadores 9001 y 9002 de la
Subestacin Antauta 60/22,9 kV, ubicada en la localidad de Antauta
El Sistema Elctrico CRUCERO III ETAPA que administra ELECTRO PUNO S.A.A, es un
sistema interconectado al SEIN.

P033272

RE A LI ZAC I N DE E S TUD I OS PA R A E L DE S AR R OLLO DE


PR OY E C TOS D E E LE C TR I FIC A CI N RU RA L, FU E R A DE L R E A
DE C ON CE S I N D E LA S E MPR E S AS D IS TRI B UI D ORA S DE
EN ER G A E LC TRI C A, A NI V E L N AC I ON A L GR UP O I

1.2

BALANCE OFERTA DEMANDA

DESCRIPCION

2 011

2 012

2 016

2 021

2 026

2 031

Subestacin Antauta 60/22,9 Kv - 6/8 MVA ;Onan-Onaf (kW) (1)

5 400

5 400

5 400

5 400

5 400

5 880

Total de Oferta S.E. Antauta - kW

5 400

5 400

5 400

5 400

5 400

5 880

1 210

1 246

1 403

1 626

1 885

2 185

420

433

487

564

654

759

SER CRUCERO III ETAPA (4)

128

141

155

170

184

Proy. Futuros (kW) (5)

77

89

103

120

Total Demanda del Sistema Electrico (kW)

1 630

1 807

2 107

2 435

2 813

3 248

BALANCE OFERTA - DEMANDA - kW

3 770

3 593

3 293

2 965

2 587

2 632

Oferta Disponible

Demandas en el Sistema Elctrico


9001 22,9 kV LP Antauta , Carlos Gutierrez, Potoni, Crucero. (3)
9002 22,9 kV LP. Cumani, Macusani, Ajoyani. (3)

(1) El transformador de la S.E. Antauta trabajar con su ventilacin natural durante el horizonte de evaluacin.
(2) Se est considerando un factor de potencia de 0,9
(3) Demanda de Alimentadores Existentes
(4) Demanda del Proyecto
(5) Demanda de Proyectos futuros

5.

ALCANCES DEL PROYECTO


1.3

DE LAS LNEAS PRIMARIAS

Las lneas primarias estn compuestas por los siguientes tramos:


Descripcin
- Linea Primaria 1 13,2 kV,1x35 mm2AAAC

148,53 km.

Relacin de Derivaciones de Lneas Primarias


N de
Derivaci
n

Descripcin del
Tramo

Distancia
Total
(km)

Nivel de
Tension
(kV)

Calibre
Conductor

DV N 1

L.P. PINAYA MOCCO

0,697

13,2

1x35mm AAAC

DV N 2

L.P. TOCCA ALTO

2,959

13,2

1x35mm AAAC

DV N 3

L.P. SAN JUAN HUANCAMAYO


(3)

0,398

13,2

1x35mm AAAC

DV N 4

L.P. URAPATA

0,753

13,2

1x35mm AAAC

DV N 5

L.P. JANCCAYO

3,697

13,2

1x35mm AAAC

DV N 6

L.P. ACCOPUJIO

0,587

13,2

1x35mm AAAC

DV N 7

L.P. CHILLIPUJRO

0,383

13,2

1x35mm AAAC

DV N 8

L.P. TARACUNCA

1,018

13,2

1x35mm AAAC

DV N 9

L.P. CHILLCUNO GRANDE

0,366

13,2

1x35mm AAAC

DV N 10

L.P. PATAHUASI - CHACURI


CUCHO

0,571

13,2

1x35mm AAAC

DV N 11

L.P. CONDORTIANA

0,201

13,2

1x35mm AAAC

DV N 12

L.P.VIZCACHANI CHILLAHUITIRA

0,884

13,2

1x35mm AAAC

DV N 13

L.P. PAMPAHUASI

0,701

13,2

1x35mm AAAC

DV N 14

L.P. CAYRAA

0,979

13,2

1x35mm AAAC

DV N 15

L.P. CHINGO (2)

2,432

13,2

1x35mm AAAC

DV N 16

L.P. CAYANDIA

1,481

13,2

1x35mm AAAC

DV N 17

L.P. MACHUCANCHA

8,632

13,2

1x35mm AAAC

DV N 18

L.P. PAMPA CANCHA

5,715

13,2

1x35mm AAAC

DV N 19

L.P. KENAMARI

1,201

13,2

1x35mm AAAC

DV N 20

L.P. HUANCO QUINRA

6,094

13,2

1x35mm AAAC

DV N 21

L.P. QUILCA

1,920

13,2

1x35mm AAAC

DV N 22

L.P. JILASULLCA

3,560

13,2

1x35mm AAAC

DV N 23

L.P. ANTACUNTO

17,322

13,2

1x35mm AAAC

DV N 24

L.P. JACHATICA

1,353

13,2

1x35mm AAAC

DV N 25

L.P. JILAC CAJAMARCA (1)

0,317

13,2

1x35mm AAAC

DV N 26

L.P. JILAC CAJAMARCA (2)

0,266

13,2

1x35mm AAAC

DV N 27

L.P. POTONI CANGALLI

0,654

13,2

1x35mm AAAC

DV N 28

L.P. ANTAPARADA

8,588

13,2

1x35mm AAAC

DV N 29

L.P. LOURDES

0,166

13,2

1x35mm AAAC

DV N 30

L.P. PASTO GRANDE

0,279

13,2

1x35mm AAAC

DV N 31

L.P. COLLPAPAMPA

1,306

13,2

1x35mm AAAC

DV N 32

L.P. LLAULLI (2)

3,956

13,2

1x35mm AAAC

DV N 33

L.P. MERCEDES (2)

4,781

13,2

1x35mm AAAC

N de
Derivaci
n

Descripcin del
Tramo

Nivel de
Tension
(kV)
13,2

1x35mm AAAC

14,865

13,2

1x35mm AAAC

2,184

Calibre
Conductor

DV N 34

L.P. MERCEDES (1)

DV N 35

L.P. CULLCO BELEN

DV N 36

L.P. CESAR VALLEJO (4)

0,163

13,2

1x35mm AAAC

DV N 37

L.P. CULLCO JURINSAYA

0,558

13,2

1x35mm AAAC

DV N 38

L.P. SAN JUAN HUANCAMAYO


(2)

0,712

13,2

1x35mm AAAC

DV N 39

L.P. APHARUYO

2,201

13,2

1x35mm AAAC

DV N 40

L.P. CCAPAC ORCCO

12,125

13,2

1x35mm AAAC

DV N 41

L.P. CHUINI

18,357

13,2

1x35mm AAAC

DV N 42

L.P. AQUELE

0,301

13,2

1x35mm AAAC

DV N 43

L.P. JAPO ARICOMA

9,445

13,2

1x35mm AAAC

DV N 44

L.P. HUANCARANI

0,496

13,2

1x35mm AAAC

DV N 45

L.P. OLOPIA

0,488

13,2

1x35mm AAAC

DV N 46

L.P. QUECHAPATA

0,223

13,2

1x35mm AAAC

DV N 47

L.P. ESQUENA ALTO

0,459

13,2

1x35mm AAAC

DV N 48

L.P. CAPITANA

0,266

13,2

1x35mm AAAC

DV N 49

L.P. UCHUHUMA BARRIO BAJO

0,256

13,2

1x35mm AAAC

DV N 50

L.P. QUISHUATIRA

0,196

13,2

1x35mm AAAC

DV N 51

L.P. NUEVA ESPERANZA

0,392

13,2

1x35mm AAAC

DV N 52

L.P. OSCOBAMBA

0,376

13,2

1x35mm AAAC

DV N 53

L.P. SAN JUAN HUANCAMAYO


(1)

0,246

13,2

1x35mm AAAC

TOTAL

1.4

Distancia
Total
(km)

148,53 km

DE LAS REDES DE DISTRIBUCIN

El proyecto considera la implementacin de las redes primarias de 71 localidades, en 13,2


kV, 1x35mm AAAC. A continuacin se muestran la relacin de localidades beneficiadas:
Localidades beneficias en el rea de Influencia del Proyecto

ITE
M

LOCALIDAD

CATEGORIA
DE
LOCALIDAD

DEPARTAMEN PROVINCI
DISTRITO
TO
A

COMUNIDA
D

PUNO

CHILLCUNO GRANDE

SECTOR

PUNO

PINAYA MOCCO

SECTOR

PUNO

TOCCA ALTO

SECTOR

PUNO

TOCCA BAJO

SECTOR

PUNO

OLOPIA

SECTOR

PUNO

URAPATA

PUNO

PACAJE HUANUTUYO

SECTOR
PARCIALIDA
D

ACCOPUJIO

PUNO

10

CHIMOCCO

SECTOR
PARCIALIDA
D

11

TARACUNCA

SECTOR

PUNO

12

JANCCAYO

SECTOR

PUNO

13

CHILLIPUJRO

SECTOR

PUNO

14

VIZCACHANI

SECTOR

PUNO

15

QUECHAPATA

SECTOR

PUNO

16

CHILLAHUITIRA

SECTOR

PUNO

17

MAMANI HUACHANA

SECTOR

PUNO

18

PUSKA

SECTOR

PUNO

19

CHIMBOYA

SECTOR

PUNO

20

CHACURI CUCHO

SECTOR

PUNO

21

CONDORTIANA

SECTOR

PUNO

22

PATAHUASI

SECTOR

PUNO

23

CCACCACHUPA

SECTOR

PUNO

24

CAYANDIA

PUNO

25

CAPITANA

SECTOR
PARCIALIDA
D

26

TAQUIPALCA

PUNO

27

CHINGO

SECTOR
PARCIALIDA
D

28

QUISHUATIRA

PUNO

29

NUEVA ESPERANZA

30

CAYRAA

31

ESQUENA ALTO

32

UCHUHUMA BARRIO BAJO

SECTOR
PARCIALIDA
D
PARCIALIDA
D
PARCIALIDA
D
PARCIALIDA
D

ANTAJAHUA

PUNO

PUNO

PUNO

PUNO

PUNO
PUNO
PUNO
PUNO

CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY
A
CARABAY

MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
MACUSA
NI
CORANI
CORANI
CORANI
CORANI
CORANI
CORANI
CORANI
CORANI
CORANI
CORANI
COASA
COASA
COASA
COASA
COASA
COASA
COASA
COASA
COASA

ABONADO
S
DOMESTIC
OS

ABONADO
S
CARGAS
ESPECIALE
S

39

10

14

17

27

12

21

10

16

12

19

24

21

19

6.

DESCRIPCIN DEL PROYECTO


1.5

LNEAS Y REDES PRIMARIAS

Las principales caractersticas del sistema son las siguientes:


- Tensin nominal del sistema
:
13,2 kV
- Configuracin
:
1
- Tensin Mxima de servicio
:
25 kV
- Frecuencia
:
60 Hz
- Factor de Potencia
:
0,90 (atraso)
- Conexin del Neutro
:
Efectivamente puesto a tierra.
La distancia promedio entre estructuras para las lneas primarias es de 206 m, mientras que
las redes primarias tendrn una vano promedio de 67m con vanos entre 28m y 138m.
La franja de servidumbre ser de 11 m, segn el Cdigo Nacional de Electricidad Suministro 2001, mientras que el equipamiento previsto para las lneas y redes primarias es
el siguiente:
- Estructura
Monoposte, conformado por postes de 11 y 12 m de Concreto
Armado Centrifugado.
- Cruceta La cruceta debe ser Tornillo y deben ser tratados bajo el mtodo vaco presin, con el preservante compuesto de sales CCA-tipo C - factor Oxido 70% y una
concentracin de 5 %. La retencin del preservante CCA-C en la madera de las
crucetas tipo Tornillo debe ser de 3 kg/m como mnimo.
- Conductores Aleacin de aluminio de 35 mm AAAC.
- Aislador Porcelana, tipo Pin Ansi 56-3, y tipo suspensin Polimericos.
- Secc. Fusible Tipo Cut Out, 27 kV, 150 kV-BIL, 100 A.
- Pararrayos
Oxido Metlico 21 kV clase distribucin.
- Retenidas
Cable de acero SM de 10 mm, varilla de anclaje de 2,4 m x 16
mm, bloque de anclaje de 0,4 x 0,4 x 0,15m.
- Puesta a tierra Compuesto por varilla de acero recubierto de cobre de 2,4 m x 16 mm
, conductor bajada de Cu 16 mm.
1.6

SUBESTACIONES DE DISTRIBUCIN
-

Transformadores de distribucin 1 13,2/0.46-0,23 kV de 5,10 y 37,5 KVA.


Seccionador fusible de expulsin, tipo Cut Out, 27 kV, 150 kV-BIL, 100 A.
Pararrayos de xido Metlico 21 kV clase distribucin, 10 kA.
Tablero de distribucin para sistema 440/220 V.
La estructura a utilizar en las subestaciones de distribucin ser Monoposte,
compuesta por un equipamiento similar al de las lneas y redes primarias descritas
anteriormente.
Subestaciones de Distribucin: En las subestaciones de distribucin se contar con
una puesta a tierra, seleccionada de acuerdo a su resistividad, pudiendo ser del tipo
PAT-2, la cual se conectar al borne del neutro de AT, al borne del neutro de BT y la
carcasa. Los electrodos sern de 2,4 m y 16 mm, y el conductor de bajada de
cobre ser de 16 mm, los pozos de puestas a tierras llevarn caja registro de
concreto y la conexin varilla 16mm y conductor de Cu 16 mm ser con conexin
termo-soldada.
Para las redes secundarias 1 440/220 V, la Norma DGE establece el valor 10
para la resistencia del neutro a tierra, con todas las puesta a tierra-PT conectadas de
BT, incluyendo la primera PT de BT de la subestacin. Con ello se garantiza que

cuando ocurre una falla a tierra en una de las fases, la tensin fase-neutro no debe
superar la tensin de 250 V (desplazamiento del neutro).
Los valores mximos de la resistencia de puesta tierra en las subestaciones de
distribucin 1 de sistemas MRT, sin considerar la conexin del neutro de las redes
secundarias, debern ser los siguientes:
POTENCIA DEL
TRANSFORMADOR
37,5 kVA, 1-MRT
10 kVA, 1-MRT
5 kVA, 1-MRT

RESISTENCIA
(OHM)
15
25
25

1.7 REDES SECUNDARIAS


Las redes secundarias de las 71 localidades beneficiadas, conformadas por las redes de
baja tensin, 1 440/220 V.; se tiene la siguiente descripcin:
Postes de concreto armado centrifugado 8 m / 200 daN.
Cables autoportantes de aluminio, con cable portante de aleacin de aluminio
desnudo de 25 mm de seccin.
El alumbrado pblico constar de luminarias con lmparas de vapor de sodio de alta
presin de 50 W soportadas por pastorales de AG.
Puesta a tierra, conformado por conductor de cobre desnudo 16 mm de seccin y
electrodo de acero recubierto de cobre de 16 mm x 2,40 m de longitud.
Ferretera de acero forjado y galvanizado en caliente.
Conexiones domiciliarias area, monofsica, con medidor de energa monofsico
220V-10A, con cable de cobre 2x4 mm, caja porta medidor tipo L y material
accesorio de conexin (incluye conector bimetlico).

Las conexiones domiciliarias sern areas, compuestas de cable concntrico con conductor
de cobre de 2x4 mm, caja portamedidor y material accesorio de conexin y soporte del
cable de acometida. Las cuales irn empotrados directamente hasta la caja de medicin o
caja toma.
Para el presente proyecto se estn utilizando las siguientes acometidas domiciliarias:
- Acometidas domiciliarias, configuracin corta y larga en murete: se est
considerando la utilizacin de muretes para las acometidas domiciliarias largas y
cortas solamente por la precariedad de las fachadas.
- Acometidas domiciliarias, configuracin corta y larga: en el caso que las viviendas
sean de material noble y/o adobe la caja porta medidor y el tubo de acometida se
empotrarn en la pared y sern cubiertos con mortero de cemento-arena o yeso
dependiendo de la naturaleza de la pared de la vivienda.
- Los vanos mximos de conexin domiciliaria por tipo de configuracin son:
- Configuracin corta en murete
:
15 m
- Configuracin larga en murete
:
25 m
- Configuracin corta
:
15 m
- Configuracin larga
:
25 m

7.

PRESUPUESTO DE OBRA
El costo total del proyecto, a enero 2012 se adjunta en el siguiente cuadro:

8.

PLAZO DE EJECUCION
El tiempo estimado para la ejecucin de Obras Civiles y Montaje Electromecnico es de 300
das calendario.