SC CODE DESCRIPTIONS
SC101: Xenon lamp error (A193/A224)
- Definition - [B]
The standard white level was not detected properly when scanning the white
plate.
- Possible cause Xenon lamp defective . Xenon lamp harness defective
SBU board defective . SBU harness defective
AF 200/250
Lamp regulator defective
Exposure lamp deective .
Dirty white plate
AF 200/250
Poor connection of the interface harness which connects the LD unit and
the BiCU board
Temperature around the LD unit is too high
AF 200/250
The paper upper limit sensor is not activated after the tray lift motor has been
on for 10 seconds.
- Possible causes Upper limit sensor defective . Tray lift motor defective .
IOCSS board defective
SC506: Paper tray unit main motor lock (optional paper tray unit
only) (A193/A224)
-Definition- [C]
A main motor lock signal is detected for more than 5 seconds or the lock
signal is not detected for more than 5 seconds during rotation.
- Possible causes Paper tray unit main motor defective . Too much load on the drive mechanism
AF 200/250
AF 200/250
The BICU board cannot communicate with the printer controller properly.
- Possible causes Poor connection of the interface harness which connects the BICU board
and the mother board.
Poor connection between the mother board and the printer controller
BICU board defective . Printer controller defective . Mother board defective
AF 200/250