Technical

Data

1107 Advantagetm Grout DOT


Cement Based, Non-Corrosive, Non-Shrink Grout

PRODUCT DESCRIPTION:
1107 Advantage Grout DOT is a cement based prepackaged grout. 1107 Advantage Grout DOT is
non-corrosive, non-shrinking, and is formulated with
the highest quality ingredients.
PURPOSE:
1107 Advantage Grout DOT is designed for grouting of
anchor bolts, dowels, and other miscellaneous items in
concrete, as well as for placement in shear keys between prestressed concrete beams and hollow slab
units.
ADVANTAGES:
Controlled, Net Positive Expansion
Non-Shrink
Non-Metallic/Non-Corrosive
Multi Use Material
MEETS SPECIFICATIONS:
ASTM C-1107-Meets Grade C requirements for
Non-Shrink Grout

Flowable Consistency:
Compressive Strength (ASTM C-109)
3 days
4500 psi
7 days
5800 psi
28 days
6800 psi
Expansion Percentage (CRD C-621)
3 days
0.03%
14 days
0.03%
28 days
0.03%
Fluid Consistency:
Compressive Strength (ASTM C-109)
3 days
3500 psi
7 days
5000 psi
28 days
7200 psi
Expansion Percentage (CDR C-621)
3 days
0.01%
14 days
0.01%
28 days
0.01%

31.0 MPa
40.0 MPa
59.3 MPa

24.1 MPa
34.5 MPa
49.6 MPa

Placement:
Follow the standard grouting procedures and recommendations of ACI-351 for placement and curing of
grout. Grout can be rodded or vibrated, however, grout
should not be over-worked causing segregation. Take
care to remove all air voids. Placement and consolidation should be continuous for any one section of grout.
When nearby equipment causes vibration of the grout,
such equipment should be shut down during and for a
minimum of 8 hours after application.

34.5 MPa
50.3 MPa
72.4 MPa

(Continued on Back)

3
CONCRETE

TEST RESULTS:
Plastic Consistency
Compressive Strength (ASTM C-109):
3 days
5000 psi
7 days
7300 psi
28 days
10500 psi
Expansion Percentage (CDR C-621)
3 days
0.05%
14 days
0.05%
28 days
0.05%

Dayton Superior
Chemical & Cement Products

1107 Advantage Grout DOT meets or exceeds requirements for these New York DOT specifications:
701-05 Concrete Grouting Material: For use in
grouting anchor bolts, dowels, and other miscellaneous items in concrete.
701-06 Cement Based Grout Materials For shear
Keys: Cement based grout for the placement in
shear keys between prestressed concrete beam
and hollow slab units.

APPLICATION INSTRUCTIONS:
Surface Preparation:
Remove all dirt, oil, and grease or contaminates from
the surfaces to be grouted. Remove all unsound or
loose material. When possible roughen adjacent concrete surfaces. Metals that will come in contact with
grout must be free of rust, paints, oils, and grease.
Provide air relief openings (vents) where needed to
avoid entrapment of air. Thoroughly wet all grouting
areas with water and keep wet at least 3 hours and
preferable 24 hours prior to placement of grout. Remove any excess surface water prior to placement.

1107 ADVANTAGETM GROUT DOT


Cement Based, Non-Corrosive, Non-Shrink Grout

Mixing and Proportioning:


Mix only enough material that can be placed within 15
minutes. A mechanical mixer with rotating blades is
recommended. Small quantities can be mixed with hand
tools. Place the recommended amount (see chart below) of potable water into the mixer, then add 1 bag, 50
lbs (22.7 kg) of grout into the water with the mixer running. Multi bag mixes are acceptable provided they can
be mixed and placed within 15 minutes. Mix until the
material is lump free and uniformly blended (approximate mix time is 5 minutes). Place the material
immediately after mixing. Do not retemper mix. Optimum air temperature for placing the grout is 72F
(22C). Temperature variations will cause differences
in curing times. Refer to Finishing and Curing section
for additional information.
Consistency
Plastic
Flowable
Fluid
NY DOT SPEC
701-05 (Anchoring)
NY DOT SPEC
701-06 (Shear Keys)

Water per 50 lb. (22.7 kg) Bag


6.5 - 7 pints (3.0-3.3L)
7.0 - 8 pints (3.3-3.7L)
8.0 - 9 pints (3.7-4.2L)

7.43 pints (3.5L) maximum


8.40 pints (3.9L) maximum

Finishing and Curing:


Exposed grout surfaces should be cured. Contact Dayton Superior for specific curing compound
recommendations. Maintain the temperature of the grout
and contact areas at 45F to 80F (7C to 27C) for a
minimum of 24 hours. Setting time for the grout will
slow down during cold weather less than 45F (7C)
and speed up during hot weather greater than 80F
(27C). Contact Dayton Superior for specific recommendations.
Warranty, Warranty Disclaimer and Exclusive Remedy - Dayton Superior Chemical Division warrants, for 12
months from the date of manufacture or for the duration of the published product shelf life, whichever is less, that at the
time of shipment by (the Company), the product is free of manufacturing defects and conforms to (the Companys)
published specifications in force on the date of acceptance by (the Company) of the order. (the Company) shall only
be liable under this warranty if the material has been applied, used, and stored in accordance with (the Company)
instructions in this technical data sheet.

SPECIAL CONDITIONS:
In hot or cold temperatures or unusual conditions such
as mass pours, thin layers, extreme temperature service, restraint of movement, or when long pumping
distances are anticipated, contact Dayton Superior for
specific recommendations.
CLEAN-UP:
Clean tools and spills immediately with clean water.
Hardened material will require an abrasive cleaning
method.
PACKAGING AND YIELD:
50 lb. (22.7 kg) multi wall, plastic lined bags. Approximate yield per bag: .43 ft3 (.0122 m3)
LIMITATIONS:
Handle 1107 Advantage Grout DOT as you would
concrete. Protect it against temperatures and
weather. Do not exceed ACI limitations on placement of grout.
Exposed finished grout should be cured.
Do not add any other cements, additives, or aggregates.
Do not retemper after initial mixing.
Placing grout at temperatures less than 45F (7C)
is not recommended.
WARNING:
Avoid direct contact with skin and eyes. Product contains Portland Cement. Wash exposed skin areas with
water. May cause skin irritation and possible cement
burns. In case of eye contact, flood repeatedly with
water and call a physician. Do not take internally. Harmful if ingested. Refer to the Material Safety Data Sheet
(MSDS) for additional information
TECHNICAL SERVICES:
Call the technical staff for assistance at:
1-866-329-8724
1-913-233-1750
or
Fax: 913-279-4806

The purchaser must examine the product when received and promptly notify (the Company) in writing of any nonconformity before the product is used, or no later than 30 days after such non-conformity is first discovered. If (the
Company), in its sole discretion, determines that the product breached the above warranty, it will, in its sole discretion,
replace the non-conforming product, refund the purchase price or issue a credit in the amount of the purchase price. This
is the sole and exclusive remedy for breach of this warranty.
Only a (Company) officer is authorized to modify this warranty. The sales information on the (the Companys)
website and received by the customer during the sales process does not supersede this warranty and the specifications of
the product in force on the date of sale. THE FOREGOING WARRANTY SHALL BE EXCLUSIVE AND IN LIEU OF
ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE AND ALL OTHER WARRANTIES OTHERWISE ARISING BY OPERATION OF LAW, COURSE OF DEALING, CUSTOM, TRADE OR OTHERWISE.

Limitation of Liability Dayton Superior Chemical Division shall not be liable in contract or in tort (including, without
limitation, negligence, strict liability or otherwise) for loss of sales, revenues or profits; cost of capital or funds; business
interruption or cost of downtime, loss of use, damage to or loss of use of other property (real or personal); failure to realize
expected savings; frustration of economic or business expectations; claims by third parties (other than for bodily injury),
or economic losses of any kind; or for any special, incidental, indirect, consequential, punitive or exemplary damages
arising in any way out of the performance of, or failure to perform, this Agreement, even if (the Company) could
foresee or has been advised of the possibility of such damages. The Parties expressly agree that these limitations on
damages are allocations of risk constituting, in part, the consideration for this agreement, and also that such limitations shall
survive the determination of any court of competent jurisdiction that any remedy provided in these terms or available at
law fails of its essential purpose.

Visit the website at: www.daytonsuperiorchemical.com

Dayton Superior Specialty Chemical Division


4226 Kansas Avenue, Kansas City, KS 66106
Telephone: (913) 233-1750

FOR INDUSTRIAL USE ONLY

7-02BV

Вам также может понравиться