Вы находитесь на странице: 1из 89

Rseau Tlcoms SONELGAZ

Intgration & Gestion des FOX515


ABB Group
February 4, 2011 | Slide 1

AGENDA du 8 fvrier 2011

Introduction FOX515 (Base installe et modules/services


supplmentaires)

Modules optiques

Tlphonie

Donnes numriques

Tlprotection

Ethernet

Introduction & Informations des MUX du rseau Sonelgaz

Intgration FOX515

Systme de gestion (NMS)

ABB Group
February 4, 2011 | Slide 2

Exemples

FOXMAN-UN

Discussion et Conclusions

FOX515 Base installe/livre totale 339 (12/2010)

ABB Group
February 4, 2011 | Slide 3

FOX515 Concept

Ce qui rend le FOX 515 une vraie


plate-forme pour les socits de
service publiques c'est
l'intgration de tout types de
modules de transmission et de
tlprotection
la possibilit des cross-connexion
internes entres les diffrents modules
de transmission
la grande flexibilit

la gamme exhaustive de types de


modules

redondance de la CPU et de
lalimentation
ABB Group
February 4, 2011 | Slide 4

FOX515 Concept:

Concept Mcanique:

21 positions/slots pour modules, inclus


alimentation et unit centrale

Version 19- ou ETSI

Trs haute fiabilit

Bas sur des standards internationaux


(ITU-T, IEC, IEEE, EN, ETS)

Compatibilit Electromagntique:

ABB Group
February 4, 2011 | Slide 5

Un rail pour la mise la terre permet une


propre protection.

Le couvercle avant assure la protection EMC

Test par des laboratoires indpendants


(KEMA)

Access Bus
UBUS 4 Hwy.s
UBUS 4 Hwy.s
PBUS
SBUS

SBUS

SectorA

SectorB

CU CU

Power Supply Unit POSUM


1

10

11

12

13

14

15

16

17

18

19

20

21

CU = Control Unit

ABB Group
February 4, 2011 | Slide 6

Structure Bus Complte


SYNIC

SYNIF

2xVC-4

SYNUF

NEBRx

S-BUS

SYN4E

SYNAC

SYNVA

SYNOT

TUPON

SYNVA

SYNAC

SYN4E

DATAx

NEMSG

P-BUS

128x2Mb/s

STICx

LAWA4
ETER1

LOMIx

COBU<X>

GECOD

PHLCx
SUBHx

U-BUS

8x2Mb/s

ABB Group
February 4, 2011 | Slide 7

SYNIO

2xVC-4 S-BUS
Slot 15..20>Sector B

Slot 2..9>Sector A

OPTIF

SYNAM

UNIDA

TEBIT

OTERM

EXLAN

NEMCA

Unit de contrle: COBUx

ABB Group
February 4, 2011 | Slide 8

Gre la synchronisation

SDH/ PDH synchronisation

Entres et sorties synchronisation

Contient une base de donnes du systme


(logiciel et configuration)

Fournit linterface de gestion (F, Qx, ECC)

Contient un routeur IP pour le ECC (canal de


communication intgr)

Connecte UBUS et PBUS

Intgre 4 entres dalarmes

Fournit 2 sorties dalarmes

Contient un gnrateur / analyseur de


signaux intgr pour la diagnostique

Permet la configuration redondante...

Protection MUX FOX515

ABB Group
February 4, 2011 | Slide 9

Modules SDH
SYN4E module optique avec 4 x cages SFP

ABB Group
February 4, 2011 | Slide 10

4 x cages pour units SFP pour:


4 x STM-1 (155Mbit/s):
S-1.1, L-1.1, L-1.2, X.1.2, U-1.2 et CWDM
Max. 2 x STM-4 (622Mbit/s):
S-4.1, L-4.1, L-4.2, X.4.2 et CWDM

Nombre des circuits:


2 circuits optique STM-4 or STM-1
2 circuits optique STM-1
4 circuits FastEthernet & Gigabit Ethernet (lectrique RJ45)

Connecteur Optique Type: LC/PC

Fonctionnalits principales du 10/100/1000Base-T Ethernet:

Modes: Auto-ngociation, semi duplex et duplex parfait

Flow control, Trame jusqu 1600 bytes

EoS over VC-4, VC-3 and VC-12

VCAT (Virtual Concatnation)

LCAS (Link Capacity Adjustment Scheme)

FOX515: Interface Optique utilisant technologie SFP

Distances, exemple pour STM-1:

Court:

12dB for up to 20km


S-1.1 on 1310nm

Medium:

20dB for up to 60km


L-1.1 on 1310nm

Long:

28dB for up to 100km


L-1.2 on 1550nm

Extra-long:

32dB for up to 120km


V-1.2 on 1550nm

Ultra-long:

50dB for up to 160 200km


U-1.2 on 1550nm

SFP: Small Form Factor Pluggable transceiver

ABB Group
February 4, 2011 | Slide 11

Modules SDH
SYN4E module optique avec capacit STM- 1/4

STM-4 ou STM-1

STM-4 ou STM-1

Capacit Add-Drop locale:


SDH

Ethernet

PDH

2 x STM-1
155Mbit/s

4 x Ethernet, lectrique
10 100 1000Mbit/s

4 x E1 (2Mbit/s)
to / from PBUS

Optique

ABB Group
February 4, 2011 | Slide 12

lectrique (RJ45)

SDH
3 x VC-3, 63x VC-12
to / from SBUS

P-BUS

S-BUS

FOX515 internal)

(FOX515 internal )

FOX515
Extension: Du STM-1
N x E1

STM-1

Ethernet/IP
Traffic

voice
legacy data

Rseau STM-1

STM-1

ABB Group
February 4, 2011 | Slide 13

STM-1

FOX515
Extension: au STM-4
N x E1

STM-1

Ethernet/IP
Traffic

voice
legacy data

Rseau STM-4

STM-1

En changeant le SFP
ABB Group
February 4, 2011 | Slide 14

STM-1

Modules Phonie
NEMSG 2/4 fils E&M

8 x interfaces frquence audio (AF)


300 Hz ..3.4 kHz

Confrence vocale

Compatible avec NEMCA

EXLAN (Exchange Line Analogue)

12 interfaces de autocom pour des connections d'abonn

simule un tlphone vers lautocom

SUBHx (Subscriber high density line card)

ABB Group
February 4, 2011 | Slide 15

10/ 30 interfaces 2-fils pour des connections dabonn

Le FOX515 permet l'extension d'une ligne d'abonn 2-fils


travers un rseau de transmission en utilisant les
modules EXLAN (cot PAX) et SUBHx (cot abonn)

Modules Phonie
Application: Liaison prdtermine (Hot Line) et abonn loign

Direct Hot Line


without PABX
SUBH1 SUBH1

ABB Group
February 4, 2011 | Slide 16

Remote Subscriber
EXLAN SUBH1

Modules Phonie
Application: 4-fils E&M et VF Modem

FOX 515

VC 4

STM1

VC 4

SYNxx

VC 4

SYNxx
VC 4

STM1

FOX 515

STM1

Modem

Modem

cross-connect

cross-connect

2/4 Wire

ABB Group
February 4, 2011 | Slide 17

4 Wire E&M

NEMCA
NEMSG

64k

Connectivity
over SDH/PDH

NEMCA
NEMSG

4 Wire E&M

ATU-EM

PABX
e.g
IS30x0/
IPS2000

ATU-EM

64k

2/4 Wire

PABX
e.g
IS30x0/
IPS2000

Module Donnes Numriques: DATA<X>

DATA4/DATAR V.24/V.28 (4 interfaces)


4x V.24/V.28, RS-232 0...0.3kbit/s transp
(V.110)
0.6kbit/s...38.4kbit/s sync/async (V.110)
1x 10/100BaseT Bridge

DATA3/DATAV V.35 (4 interfaces)


4x V.35 48, 56, nx64kbit/s (n=1-31) sync
0.6kbit/s...38.4kbit/s sync/async (V.110)
1x 10/100BaseT Bridge

DATA1/DATAT X.24/V.11 (4 interfaces)


4x X.24/V.11 48, 56, nx64kbit/s (n=1-31) sync
0.6kbit/s..38.4kbit/s sync/async (X.30)
1x 10/100BaseT Bridge

DATA5/DATAS universel (4 interfaces)


4x V.24/V.28, V.35, X.24/V.11, RS485
software programmable
1x 10/100BaseT Bridge

LAN Port 10/100BaseT

ABB Group
February 4, 2011 | Slide 18

Module Donnes Numriques: DATA<X>


(Version HW R1A)
DCE
Interface
Type

Unit Name

Network Functions

X.21/V.11

V.35

V.24/V.28

LAN 10/100BaseT
Bridging, (IF-4 only)

RS485

Subrate Multiplexing

4 IF

4 IF

4 IF

1 IF

4 IF

1+1 Path Protection


Performance Monitoring Time Slot
Point to Multipoint Application

DATAS 512

yes

yes

yes

yes

yes

yes

DATA5 513

yes

yes

yes

yes

yes

no

DATAV 514

no

yes

no

yes

no

yes

DATA3 515

no

yes

no

yes

no

no

DATAR 516

no

no

yes

yes

no

yes

DATA4 517

no

no

yes

yes

no

no

DATAT 518

yes

no

no

yes

no

yes

DATA1 519

yes

no

no

yes

no

no

ABB Group
February 4, 2011 | Slide 19

Module Donnes Numriques


DATA<X>: Application Systme Scada

Protocole 101: Interface


donnes lectrique

Protocole 104: Interface


LAN

ABB Group
February 4, 2011 | Slide 20

PDH LOMI4/LOMIF

Interfaces numriques 4 ou 8 * 2Mbit/s avec


(G.704) ou sans trame (G.703)

Accs PBUS

jusqu' 16 modules par FOX515


(cela fait un total de 128x 2Mbit/s par bti)

ABB Group
February 4, 2011 | Slide 21

Impdance de 75 ou 120 , dfini par le


type de cble et connecteur
Contient sa propre part de brasseur
numrique

LOMI4/LOMIF: Application Accs (Tributary)


Les Interfaces numriques 2 Mbit/s sont utiliss pour des
diffrentes applications:

FOX515 est utilis comme MUX de transport: Interconnexion aux


appareils terminaux (PABX, router etc.)

VC 4

SBUS

2M

PBUS

2 Mbit/s
G.703/704

ABB Group
February 4, 2011 | Slide 22

LOMIF

STM-1

VC12

VC 4

SYNIO
STM-1

LOMI4/LOMIF: Application Transport (Aggregate)

FOX515 est utilis comme MUX daccs: Interconnexion au MUX de


transport (FOX515H, FOX660 etc.)
STM-16
Mux
G.703

STM4

STM-16
Mux

STM4
n lines
2Mbit/s

G.704

STM-16
Mux
G.703

n lines
2Mbit/s

G.704

L
O
M
I
F

L
O
M
I
F

FOX 515

FOX 515

STM4

STM-16
Mux

G.703

G.703

STM4

G.704

L
O
M
I
F
FOX 515

ABB Group
February 4, 2011 | Slide 23

STM4

STM-16
Mux
n lines
2Mbit/s

G.703
G.704

L
O
M
I
F
FOX 515

G.704

L
O
M
I
F
FOX 515

Modules Tlprotection

Protection diffrentielle: OPTIF module


4 x interfaces optique selon IEEE C37.94 (nouveau
standard)

Connexion directe en optique avec RED670 (relais de


protection ABB)

Autres fournisseurs qui supportent IEEE C37.94

Tlprotection: TEBIT module

ABB Group
February 4, 2011 | Slide 24

4 x interfaces numriques pour la transmission des signaux


trs haute fiabilit (4 commandes bidirectionnels)

Support:

Dclanchement indirect (permissive)

Dclanchement direct

Blocage

Optimis pour vitesse- ou scurit

Temps de transmission rduit

Option: 8 x interfaces binaires (8 contacts bidirectionnels)

Module de Tlprotection: TEBIT

4 x commandes tlprotection

Transmission des signaux trs haute fiabilit


Cbles directement connect (48 220DC)

Transmission bidirectionnel

Optimis pour vitesse ou scurit

Temps de transmission rduit

Sorties dalarmes

Event Recorder, peut tre synchronis avec un


rcepteur GPS

Fonctionnalits spciales:

ABB Group
February 4, 2011 | Slide 25

Supervision du temps de transmission

Commutation de protection de chemin 1+1


rapide (< 4 ms)

Test en boucle

Adressage des commandes pour scurit


additionnelle

Option: 8 x interfaces binaires (8 contacts


bidirectionnels)

TEBIT: Avantages pour les Tlprotection

Fiabilit

Intgr dans un seul quipement moins de hardware, moins de cblage et


une disponibilit du systme plus leve

Rapide protection de chemin 1+1 pour chaque direction (au niveau


64kbit/s).

Scurit

ABB Safety Frame Concept (assigne une adresse pour chaque liaison

Test en boucle intgr

Supervision dun Systme de Gestion (FOXMAN, UCS-T)

Un rseau intgr Canal de tlprotection est compltement gr

Dlai de transmission de commande: Typiquement < 5 ms

Commutation de protection de chemin 1+1 rapide: Typiquement > 4 ms

ABB Group
February 4, 2011 | Slide 26

Beaucoup plus rapide que les recommandations ITU-T pour des systmes
SDH < 50 ms

Protection diffrentielle : Solution traditionnelle

Soustation B

Soustation A

MUX

OLTE

Convertisseur

OLTE

Protection
Relay

MUX

HV-line

Convertisseur

Telecommunication System
Teleprotection System / Teleprotection Function
Protection System / Protection Function

ABB Group
February 4, 2011 | Slide 28

Protection
Relay

Protection diffrentielle / OPTIF

Soustation B

Soustation A

FOX
515

FOX
515

OPTIF

Relais de
Protection

IEEE
C37.94

OPTIF

Ligne HT

IEEE
C37.94

Relais de
Protection

un systme

INTGRATION totale dans le systme de tlcommunication

Entirement inclus dans le systme de gestion FOXMAN-UN


dpannage rapide

Moins dinterfaces, moins dquipement


DISPONIBILIT de systme plus leve!

ABB Group
February 4, 2011 | Slide 29

NMS: Systme de Gestion

Protection diffrentielle / OPTIF

4 x Ports ANSI/IEEE C37.94

Relais de Protection ABB RED670

Relais de tiers avec interface C37.94

Tlprotection NSD570 avec module G1LOa

4 x Ports optiques ABB 64kbit/s sur 1310nm MM

Relais ABB REL316, REL551, REL561

Tlprotection NSD570 avec module G1LO

FOX6Plus

1 x Port Ethernet lectrique/optique

ABB Group
February 4, 2011 | Slide 30

10/100BaseT ou 100BaseFX

Protection 1+1 via N x 64kbit/s pour commutation


SYMTRIQUE de la voie Tx & Rx

Protection diffrentielle / OPTIF

ANSI / IEEE C37.94 / Faits et Avantage :

ABB Group
February 4, 2011 | Slide 31

Cest une nouvelle norme pour les relais de protection (diffrentielles)

Tous les nouveaux relais dABB (e.g. RED 670) soutiennent cette
norme

Beaucoup d'autres fournisseurs de relais de protection soutiennent


galement cette norme C37.94: e.g.: RFL, GE, Alstom

1 - 12 intervalle de temps par canal: (64 768 kbit/s)

Mdias de raccordement: Fibre Optique, multi-mode


(Plusieurs fabricants soutiennent galement la fibre mono-mode)

Dbit binaire: 2Mbit/s, ITU-T G.703 avec structure de verrouillage de


trame spcialise

Avantage: Cette norme offre

Interconnexions simples et sres

Interoprabilit entre le relais et lquipement de transmission

OPTIF Application: Relais Protection Diffrentielle


Ligne HT

FOX515

FOX515

avec module OPTIF

avec module OPTIF

Rseau Communication
e.g. STM-1
ou STM-4
4x

RED

IEEE
C37.94

Soustation A

ABB Group
February 4, 2011 | Slide 32

Voie
Donns

Voie
Donns

4x

IEEE

RED

C37.94

Soustation B

OPTIF Application: Interconnexion quipement (ABB)


A

REL /
NSD

Fibre mono mode


ABB Safety Frame Concept

Rseau SDH:

SFP avec
LC-Connecteur

STM-1 ou STM-4

FC/PC ou E2000
Connecteur

Armoire
Telecom

Armoire Relais

FOX 515

soustation

ODF

Fibre mono mode


ABB Safety Frame Concept

Rseau SDH:

REL316
REL551
REL561

FC/PC ou E2000
Connecteur

STM-1 ou STM-4

SFP avec
LC-Connecteur

FOX 515

NSD570
Armoire Telecom

soustation
ABB Group
February 4, 2011 | Slide 33

Protection diffrentielle / OPTIF


Indication LED: Statut, alarme

S/S A

S/S B

155 ou 622Mbit/s

FOX515
T1

1x Ethernet

lectrique RJ45

optique IF 100Base-FX

FOX515

IEEE
C37.94

IEEE
C37.94

T2

RED
670

RED
670

4 x C37.94 avec cages SFP


RED670 avec temporisation dcho:
Retard de Transmission Td =

ABB Group
February 4, 2011 | Slide 34

(T1 + T2)
2

Compensation de temps pour Td: jusqu 20ms

Mesure de retard (boucle):

chaque 5ms

Protection diffrentielle / OPTIF


Indication LED: Statut, alarme

S/S A
FOX515

155 ou 622Mbit/s
1re voie

S/S B
FOX515

1x Ethernet

lectrique RJ45

optique IF 100Base-FX

IEEE
C37.94

Voie de secours

IEEE
C37.94

4 x C37.94 avec cages SFP

Pour viter des faux dclanchement aprs la commutation de la 1re voie la


voie de secours, la protection diffrentielle exige:
Commutation (symtrique) bi-directionnelle des deux fibres (Rx et Tx)

ABB Group
February 4, 2011 | Slide 35

Protection du chemin
Multiplexeur typique:
secours

Transmission redondante
utilisant protection
du chemin (Nx 64kbit/s)

Principal

SANS commutation
(symtrique) bidirectionnelle des deux
fibres (Rx et Tx)!

ABB Group
February 4, 2011 | Slide 36

Station A
REL

Station B
REL

OPTIF (C37.94): Protection du chemin symtrique


Multiplexeur typique:
secours

Transmission redondante
utilisant protection
du chemin (Nx 64kbit/s)

Principal

SANS commutation
(symtrique) bidirectionnelle des deux
fibres (Rx et Tx)!

Station A
REL

FOX515 / OPTIF:
(C37.94 interface optique)
Transmission redondante
utilisant protection
du chemin (Nx 64kbit/s):

REL

FOX515

FOX515
standby

FOX515

Commutation symtrique
(Bidirectionnelle) !
=> Mme dlais pour Tx et Rx
ABB Group
February 4, 2011 | Slide 37

Station B

MAIN

FOX515
DIFF
REL

FOX515
FOX515
DIFF
REL

Protection diffrentielle / OPTIF

ABB Group
February 4, 2011 | Slide 38

Fiabilit

Intgr dans un quipement simple - moins de matriel, moins


de cblage et disponibilit de systme plus leve

Commutation symtrique permet un routage de canal


redondant mme pour des applications de protection
diffrentielle

Scurit

Supervis par systme de gestion centralis

Un rseau intgr Canal de tlprotection entier est


contrl

Boucle de teste pour la maintenance et localisation du dfaut

Commutation rapide: Typiquement < 25 ms

A capacit dvolution

Flexibilit en employant des SFP

Port optique/lectrique Ethernet pour une future migration


CEI61850

Intgration de la Vido et de la Tlphonie IP

ABB Group
February 4, 2011 | Slide 39

FOX515: Modular Concept


Ethernet/ IP interfaces

Ethernet/IP interfaces for connecting various IP


applications such as energy meters, VoIP phones or
cameras

Ethernet over SDH or PDH services

1 to 8 physical ports

10/100BaseT, 100Base/FX, 1000BaseSX/LX


ports

Point point Ethernet tunnel

L2 Switching (RSTP)

L3 routing (OSPF)

Power over Ethernet

Ethernet / IP Modules
ETER1: L2-Switch, with 16 x 2Mbit/s P-BUS access

Provides Ethernet over PDH and Ethernet over


SDH (EoS) functionality

4 x 10/100BaseT Ethernet front ports

Up to 64 P-BUS connection points

Backplane access 16 x E1 P-BUS

PPP termination (N x 64kbit/s and 2Mbit/s).

HDLC termination (N x 64kbit/s and 2Mbit/s)

Ethernet features

VLAN (IEEE 802.1Q)

VLAN Q in Q

STP/ RSTP (IEEE 802.1w)

Multiple switching instances

QoS and Traffic Management.

ETER1 Release 2

ABB Group
February 4, 2011 | Slide 40

R2: Dynamic (OSPF v2) and static routing

Ethernet / IP Modules
ETER1: Multiple bridging instances

ETER1

ETER1

PDH/ SDH Network

ABB Group
February 4, 2011 | Slide 41

For each service own logical bridge is defined in ETER1 module

Multiple bridging instances allows to separate different Ethernet/ IP


applications completely

Ethernet / IP Modules
ETER1 Application Topologies

Intgration facile de:


- Systmes contrles de postes
- LAN`s pour RTU
- LAN`s pour ordinateurs
- LAN`s pour supervision (vido)

ABB Group
February 4, 2011 | Slide 42

Topologies rseau

ETER1 permet plusieurs


topologies rseau comme
...configurations toiles
...configurations anneaux
...rseaux linaires

Ethernet / IP Modules
ETER1 SCADA application

ABB Group
February 4, 2011 | Slide 43

ETER1 caters for various network


topologies such as...
...star configurations
...ring configurations
...linear networks

Offers integrated solution for


IEC 60870-5-104
(IEC 60870-5-101 supported with DATAx)

Redundancy in control center via


redundant FOX 515 or
redundant power supply/control board

Connection redundancy via


LAN ring configuration (Router)
SDH ring configuration (Bridge)

IP-based SCADA Solution

ETER1

ETER1

Connect RTUs with nx64kbit/s to an ETHUB or ETER1

Connect Control HW to ETER1 in Control Center

Easy to maintain & extend

ABB Group
February 4, 2011 | Slide 44

ETER1

Video over IP Solution

Connect Cameras with : nx64kbit/s to ETHUB, LAWA, ETER1 or


nx2Mbit/s to NEBRO

Connect Control HW to LAWA or NEBRO in Control Center

Up-to-date Video over IP solution

ABB Group
February 4, 2011 | Slide 45

Wide Area Networks (WANs)

Connect PC`s, Printers, Servers, IP Phones with:nx64kbit/s to ETHUB, LAWA4, ETER1 or nx2Mbit/s
to NEBRO

No converter boxes needed, Integrated into one management

Easy to maintain & extend

ABB Group
February 4, 2011 | Slide 46

Ethernet/ IP Modules
NEBRO: Ethernet / GbE interface with L2 switching

6 Front ports

ABB Group
February 4, 2011 | Slide 47

10/100BaseT
100Base-FX or
1000Base-SX/LX

L2 switching including

STP/ RSTP (IEEE802.1w)

VLAN (IEEE802.1p/q)

Provides Ethernet over SDH (EoS)


Generic Framing Procedure
ITU-T G.7041
LCAS
Link Capacity Adjustment Scheme,
ITU-T G.7042
VCAT
Virtual Concatenation
Direct S-BUS access
Max. 63 x VC-12
8 x ports on S-BUS

4x Ethernet:
2x GbE:

GFP

Ethernet/ IP Modules
NEBRO: Application

NEBRO allow interconnection of different sites with different traffic priorities

RSTP (Rapid Spanning Tree Protocol) can be used to avoid loops when using
redundant paths

VCAT and LCAS allow concatenation and dynamic allocation of bandwidth without
loss of traffic when bandwidth is added/removed

ABB Group
February 4, 2011 | Slide 48

Video system: Services


Remote access via IP / SDH

ABB Group
February 4, 2011 | Slide 49

Ethernet/ IP Modules
NEBRE: Ethernet / GbE switch (no S-BUS connection)

ABB Group
February 4, 2011 | Slide 50

Integrated into FOX515

NEBRE is powered, configured and


supervised from FOX515 using UCST.

Same front-connections as NEBRO


4 x RJ45 electrical, 2x optical SFP)

Functions:

VLAN tag stacking (Q-in-Q)

Wire-speed Ethernet switching


(Supporting baby jumbo frames 1600Bytes)

VLAN tagging, bridging and trunking

Traffic prioritization according to IEEE 802.1p

Spanning Tree Protocol (STP) and Rapid


STP

Applications:

Adds L2 switching function to SYN4E

Supervised L2 GbE-switch in FOX515


networks

Ethernet/ IP Modules
SWITE: L2 switch with Power over Ethernet (PoE)

ABB Group
February 4, 2011 | Slide 51

8 x 10/100/1000 Mbit/s Ethernet front interfaces:

2 x SFP 1000Base-SX/LX/TX trunk ports

6 x RJ-45 10BaseT or 100Base-TX access


ports

No BUS access on FOX515

Power over Ethernet functionality

In total max. 60W can be allocated to the 6


access ports

Either 2 x PoE+ (27W) or 4 x PoE as per


IEEE802.3af (15W) or 60W distributed over all
6 ports

2 x PoE (up to 15W not isolated) 10/100Mbit/s

SWITE: Main Features

L2-switching including VLAN Q in Q

STP and RSTP on trunk ports

Ethernet/ IP Modules
SWITE: Application PoE
SWITE
VLAN 10

SWITE
VLAN 30

VLAN 30

VLAN 20

VLAN 10
VLAN 20

Anneau SDH avec RSTP

SWITE

Alimentation inutile
( PoE)

Serveur SIP
ABB Group
February 4, 2011 | Slide 52

VLAN 20

VLAN 30

Serveur Vido

Supervision par Vido et Tlphonie IP

Ethernet Switch
AFS650/655

DIN Rail mounted managed Ethernet Switch of


utility grade (wall mounting possible)

Metal housing

Up to 10 FE ports (electrical, optical or SFP


cages)

Up to 3 GbE ports (electrical, SFP or Combo


ports)

Multimode and Single Mode versions available

Huge variety on optical ports: SFP cages, SC,


ST,

ABB Group
February 4, 2011 | Slide 53

SFPs in various versions available (MM,


SM, single fibre)

24/36/48 VDC or 60/120/250 VDC, 110/230VAC


Power supply, Redundant Power supply possible

CRA (Configuration Recovery Adapter) port for


easy exchange of product

Supervision par Vido et Tlphonie IP

ABB Group
February 4, 2011 | Slide 54

Ethernet Switch
AFS650/655

19 managed Switch of utility grade

Metal housing, Ports on front or on rear (typical


substation config)

Modular concept, 1 module for 2 ports needed, any


combination possible (expect GbE & PoE); in total 12
slots available

High port density

Up to 28 FE ports (electrical, optical or SFP


cages)

Huge variety on optical ports: SFP cages, SC,


ST,.., MM and SM

SFPs in various versions available (MM, SM,


single fibre)

Up to 4 GbE ports (optical, electrical or combo


ports)

Up to 4 Ports PoE

Low/ High Voltage as well as AC/ DC power supply,


redundancy possible

CRA (Configuration Recovery Adapter) port for easy


exchange of product

FOX515 Base installe/livre totale 339 (12/2010)

ABB Group
February 4, 2011 | Slide 55

2x

FOX515 Base installe/livre Rgion dAlger

3x

2x

2x

2x
2x

2x

2x

ABB Group
February 4, 2011 | Slide 56

RS232

E1

FOX515 Base installe Situation actuel


Exemple / Poste 60/30 kV Bab Ezzouar

ABB Group
February 4, 2011 | Slide 57

RS232

FOX515 Base installe Situation optimise


Exemple / Poste 60/30 kV de Bab Ezzouar

ABB Group
February 4, 2011 | Slide 58

Reroutage de certains canaux dans un MUX


dfectueux

Transfrer les deux circuits


RS-232 du MUX au FOX515

Rajout dune DATA5 et


LOMIF si redondance est
requise

Prvoir un FOX515 au CRC


dOran si pas dj
disponible
Paramtrie et mise en
service du FOX515 Tiaret
et au CRC Oran

CRC ORAN

FOX515 existant peut tre


utilis

SAIDA
220/60kV
Metro 5000
(STM-16)

TIARET
220/60kV
FO / ~ 138 km

Metro 3000

FO / ~ 94 km

(STM-16)

4x STM-16

3x STM-16

Metro 5000
(STM-16)

6x STM-16

3x STM-4

1x STM-4

6x STM-4

10x STM-1

3x STM-1

10x STM-1

2x FE

2x FE

7x FE

6x E3

3x E3

9x E3

63x E1

63x E1

63x E1

FOX515

MUX
(E1)

HE539253

E1 / 2 Mbps

LOMIF

4W E&M

DATA5

FXO / FXS

2x NEMSG

RS-485
RS-232

CCN

ABB Group
February 4, 2011 | Slide 59

OUED SLY
220/60kV

E1

E1

Exemple Poste de Tiaret :

RS-232
RS-232

CRC ORAN

Backbone SDH STM-16

EXLAN
2x SYN4E
5x TEBIT

FOX515 Base installe Optimisation du Rseau


Mustapha
2x F

Amiraut

DG / CNC-R

Rgion dAlger

Ain Taya

S
F

S/H

Aurassi
S/H

Tafoura

C. Djenet

Glaciere

PCG
Alger Est

2x

S/H

3x F

B. Aknoun

Rserve

Si Mustapha

F
S

S/H

Alger Port

2x F

Hamma
S

Futur Tonic

Rserve

Sidi
Abdellah

2x

PCG
O. Fayet

Mazafran
220 kV

2x

Hydra
S/H

Kolea

3x F

2x F

Cherchel

El Afroun

S/H

Arbaa

F
2x

Onid

3x F

Onex

Meramene

3x F

4x F

2x F

Chlef 2

LEGENDE :

Ghrib
2x F

PCG
Oued Sly

Kherba
PCG
Beroughia

Ain Mrene

Aflou 2

DG :
CNC :
CNC-R :
CRC :
PCG :

Direction Gnrale
Centre National de Contrle
Centre National de Contrle de Repli
Centre Rgional de Contrle
Poste de Commande Groupe

S:
H:
F:
NMS :

MUX SDH SAGEM (ADR2500)


MUX SDH HUAWEI (OptiX xxxx)
MUX PDH/SDH ABB (FOX515)

PCG
Djelfa
F

ABB Group
February 4, 2011 | Slide 60

H
H

2x

2x F

2x

Tenes

PCG
Bouira

Meftah

PCG
El Khemis

Oum Drou

F
F

2x

2x

Oued Fedda

Chlef 1

Optimisation du Rseau :
Rajout modules optiques SYN4E
aux FOX515 existants

S. Rached
F

Dess.
Tenes

Ahmer El Ain

Mohamedia

11x F

2x

Blida

Bab Ezzouar

2x F

Birtouta

2x

CNC / CRC

S/H

PCG
B. Mered

3x

F
F

Kouba

Maza.
60 kV

Dess. Cap
Djinet

F
H

2x F

Rserve

S/H

4x F

El Harrach 2

2x F

Miyeh
Tipaza

S/H

4x F

3x

S
F

2x F

El Harrach 1

7x F

A. Benian
Douaouda

F
H

Systme de gestion ABB FOXMAN-UN

Bir Ghbalou

Intgration FOX515 au Backbone SDH STM-16

ABD / 220kV - 5km

ABD / 220kV - 5km

BIS / 400kV - 240km

CHF / 400kV - 150km

OAT / 400kV - 127km

POSTE 400/220 kV DE AIN BEIDA (FKIRINA)

Equipement SDH / HUAWEI Type OSN 3500

10x STM-16

OSN 3500
4x FE

63x E1

Equipement PDH / ABB Type FOX515

ABB Group
February 4, 2011 | Slide 61

FOX515

FOX515

5x E1

5x E1

25x RS232

25x RS232

10x RS485

10x RS485

20x 2F/4F E&M

20x 2F/4F E&M

4x TELEPROT.

4x TELEPROT.

Intgration & Optimisation FOX515 au Backbone


Exemple Poste de Khenchela
Donnes

ABB Group
February 4, 2011 | Slide 62

Rseau Tlcoms SONELGAZ


Systme de Gestion FOXMAN-UN/NV
ABB Group
February 4, 2011 | Slide 63

Systme de gestion (NMS) / FOXMAN-UN (1)


Exemple 1 / Poste de Aflou 220/60 kV

ABB Group
February 4, 2011 | Slide 64

Systme de gestion (NMS) / FOXMAN-UN (2)


Exemple 2 / Zone Industrielle dArzew PB 1 & 2
Rgion dOran

Oran Ouest

CRC Oran

S/H
F

NMS

Oran Est
S

Zone dOran

FOXMAN-UN/NV
Client

Hassi Ameur
S
3x F

ZI Arzew
PB 1

ZI Arzew
PB 2
H

C.D.M.

Petit Lac

S
F

GL2Z

GP1Z

L3Z

Resrve

NAF/RAFF

Helium II

GL4Z

Ammoniac

GP2Z

SPM

Fertalge

Asmidal

Amo-Orasc

Oran Sud

Desydro

Ravin Blanc

Fertial

Methanol

S
2x F

Zahana

Rseau dOran
Marsat
LEGENDE :
DG :
CNC :
CNC-R :
CRC :
PCG :

Direction Gnrale
Centre National de Contrle
Centre National de Contrle de Repli
Centre Rgional de Contrle
Poste de Commande Groupe

S:
H:
F:
NMS :

MUX SDH SAGEM (ADR2500)


MUX SDH HUAWEI (OptiX xxxx)
MUX PDH/SDH ABB (FOX515)

Beni Saf

F
H

CNC Alger

Backbone de lOuest
(SDH STM-16)

OuS

Khb

Khm

BeM

OuF

S/H

Kou
NMS

Systme de gestion ABB FOXMAN-UN

OSN3500 livr dans le cadre du projet dArzew


F

FOX515 livr dans le cadre du projet dArzew

ABB Group
February 4, 2011 | Slide 65

FOXMAN-UN/NV
Serveur

Systme de gestion (NMS) / FOXMAN-UN (3)


Exemple 3 / Rgion dAlger
Mustapha
Amiraut

2x F

DG / CNC-R

Rgion dAlger

Ain Taya

S
F

S/H

Aurassi
S/H

Tafoura

C. Djenet

Glaciere

PCG
Alger Est

2x

S/H

3x F

B. Aknoun

Rserve

Si Mustapha

F
S

S/H

Alger Port

2x F

Hamma
S

Futur Tonic

Rserve

Sidi
Abdellah

2x

PCG
O. Fayet

Mazafran
220 kV

2x

Hydra

S/H
3x F

2x F

Cherchel

El Afroun

S/H

Ahmer El Ain

FOXMAN-UN/NV
Serveur

Arbaa

F
2x

Blida

Mohamedia

NMS

FOXMAN-UN/NV
Client

11x F

2x

Bab Ezzouar

CRC / CNC
Alger

2x F

Birtouta

2x

CNC / CRC

S/H

PCG
B. Mered

3x

F
F

Kouba

Maza.
60 kV

Dess. Cap
Djinet

F
H

Kolea

2x F

Rserve

S/H

4x F

El Harrach 2

2x F

Miyeh
Tipaza

S/H

4x F

3x

S
F

2x F

El Harrach 1

7x F

A. Benian
Douaouda

F
H

Onid

3x F

S. Rached

Onex

2x

Meramene

PCG
Bouira

Meftah
2x F

H
F

Chlef 1

3x F

Dess.
Tenes

4x F
2x

2x

Oued Fedda

PCG
El Khemis

Oum Drou

F
H

2x F

Tenes

Chlef 2

LEGENDE :

Ghrib
H

2x

2x F

PCG
Oued Sly

Kherba
PCG
Beroughia

Ain Mrene

Aflou 2

Direction Gnrale
Centre National de Contrle
Centre National de Contrle de Repli
Centre Rgional de Contrle
Poste de Commande Groupe

S:
H:
F:
NMS :

MUX SDH SAGEM (ADR2500)


MUX SDH HUAWEI (OptiX xxxx)
MUX PDH/SDH ABB (FOX515)

PCG
Djelfa
F

ABB Group
February 4, 2011 | Slide 66

DG :
CNC :
CNC-R :
CRC :
PCG :

Systme de gestion ABB FOXMAN-UN

Bir Ghbalou

ABB Group
February 4, 2011 | Slide 67

ECC

ECC

ECC

Systme de Gestion (NMS)

ECC

ECC

Intgration & Optimisation FOX515 au Backbone


Exemple Poste de Khenchela

FOXMAN-UN Dispositifs

Systme de gestion complet pour le FOX 515 et le FOX-U de legs

Vue graphique du rseau avec nombreuses fonctionnalits

Gestion comprhensive des alarmes

Accs direct de la configuration de tous les nuds du rseau

Gestion du cheminement bout bout

Intgration des objets "trangers" pour la surveillance d'alarme et la


gestion du cheminement

ALS (Serveur dalarme) / Intgration de dispositif pour:

ABB Group
February 4, 2011 | Slide 68

ETL600, NSD570, FOX660, FOX515H Alarme et dmarrage du


logiciel de configuration propritaire (HMI, UCST, etc.)

Soutient laccs distance et serveurs redondants

Sintgre dans des systmes de gestion de niveau suprieurs

Fonctionne sur plateforme Linux

Aide Online dtaille

Plate-forme

ABB Group
February 4, 2011 | Slide 69

FOXMAN-UN R8C fonctionne sur

RedHat Enterprise Linux 5


(x86 Plate-forme)

Matriel recommand:
Postes de travail ou serveurs Dell

FOXMAN-UN Architecture de Systme

FOXMAN-UN consiste des composants


suivants :

ALS

ABB Group
February 4, 2011 | Slide 70

NEM Configurateur

NEM Navigateur de rseau

Agents

NEM Noyau avec base de donnes


inclue

Paquet de gestion de rseau

Interfaces North Bound (e.g.


SNMP)

Rseau

Dispositifs ALS:

FOX515 et/ou FOX660

ETL600 etc.

Vue graphique de rseau

ABB Group
February 4, 2011 | Slide 71

Vues gographiques et logiques du rseau


possible

Bannire dalarme pour montrer l'tat global


d'alarme du rseau

tat d'alarme d'lment de rseau


reprsent par symbole color

Accs direct tous les dtails d'alarme,


configuration de nud (cheminement incl.) et
vue de synchronisation de rseau

Vue graphique de rseau Screenshot NMS Ghana


Exemple : FOX515 et ETL600 grs par FOXMAN-UN

ABB Group
February 4, 2011 | Slide 72

Gestion dalarmes

ABB Group
February 4, 2011 | Slide 73

Information d'alarme
complte par

Bannire dalarme

Colorisation du
symbole de nud

Liste dalarme

Vue d'alarme du
chssis

Historique des
alarmes

Gestion dalarmes : Explorateur de rseau

ABB Group
February 4, 2011 | Slide 74

Les couleurs de symbole


reprsentent l'tat global
d'alarme des lments de
rseau

Des marqueurs indiquent les


alarmes non quittances

Les couleurs de la section


reprsentent l'tat d'alarme
des liens physiques pour les
raccordements optiques et
lectriques

Gestion dalarmes : Explorateur de rseau

ABB Group
February 4, 2011 | Slide 75

Permet loprateur de garder


une vue densemble sur des
rseaux complexes.

Double clic sur les symboles de


groupe pour descendre un
niveau plus bas.

Utilisez le bouton droite de la


souris pour afficher un menu
instantan avec des fonctions
particulires.

Gestion dalarmes : Statut dalarme

ABB Group
February 4, 2011 | Slide 76

Le statut d'alarme est prsent dans sa taille standard une fois


ouvert. Il peut tre rtrci pour aider conserver une bonne
visibilit de la vue de limage de fond. La version rduite ne
montre pas les noms de svrit.

N'importe quelle alarme non quittance d'une svrit est


indique par le clignotement du compteur respectif et de son
champs color.

Filtre : Appelle le dialogue de filtre de statut d'alarme qui contrle


le seuil de svrit pour le clignotement des compteurs d'alarme
aussi bien que les alarmes audibles.

Gestion dalarmes : Vue support dquipement

ABB Group
February 4, 2011 | Slide 77

La vue de matriel dun lment de


rseau (NE) fournit une prsentation
graphique du support dquipement
FOX. C'est le niveau suprieur de la
hirarchie, les niveaux plus bas
tant vue d'unit et vue de sousunit.

L'affichage fournit les dtails des


units comprenant leur tat d'alarme
aussi bien que des informations sur
llment de rseau NE FOX.

Gestion de configuration : lments de rseau


La gestion de configuration du FOXMAN-UN/NV fournit l'oprateur les fonctions
suivantes :

ABB Group
February 4, 2011 | Slide 78

Dfinition des units/sous-units


dans l'lment de rseau

Configuration des modules et


des interfaces

Interconnexion des ports


(brassage)

Ajouter la commutation de
protection

Dfinition des sources dhorloge


de llment de rseau
(synchronisation)

Gestion de configuration : Traitement du cheminement


Trail Handling
Logiciel de gestion de rseau (NP) On gagne du temps!

Loption logiciel de gestion de rseau Networking


Package fournit une fonctionnalit dinterconnexion
bout bout pour le traitement semi-automatique du
cheminement et de circuit et associe les clients aux
circuits.

Le NP pargnera du temps en
contrlant la configuration bout
bout des cheminements et des
circuits.

Permet aux oprateurs de crer


semi-automatiquement du
cheminement de 2Mb/s, 8Mb/s,
VC12 et VC3 entre deux nuds
FOX.

Soutient la cration de circuit semiautomatise de nx64kb/s et 2Mb/s


entre deux points finaux dans un
rseau FOX.

Geneva

Basel

Zurich

Le logiciel de base fournit la fonctionnalit


de base pour la gestion dlment.

ABB Group
February 4, 2011 | Slide 79

Gestion de configuration : Traitement du cheminement

ABB Group
February 4, 2011 | Slide 80

Circuits protgs

Associe les circuits aux clients

Les circuits configurs manuellement


avec le terminal d'exploitation local sont
identifis et imports

Gestion de configuration : Traitement du cheminement

Caractristiques principales (1) :

ABB Group
February 4, 2011 | Slide 81

Le FOXMAN-UN NP fournit lappui pour PDH (appui total P0 et P0_nc), SDH et


xDSL.

Le FOXMAN-UN NP soutient la modlisation du cheminement, des circuits et des


porteurs SNC (Sub Network Connection) aux couches de section, de chemin et
de circuit comme dfinie dans la recommandation G.805 de l'UIT-T.

Le FOXMAN-UN NP soutient galement des hirarchies de transmission ETSI


PDH et SDH et des structures de multiplexage.

Le FOXMAN-UN NP fournit diffrentes mthodes de protection pour le rseau


FOX515 et les couches rseau.

Protection de chemin 1+1 bout bout, e.g. pour TEBIT

Modes de protection SNC et LTP

Protection de section multiplex (MSP)

Gestion de configuration : Traitement du cheminement

Caractristiques principales (2) :

ABB Group
February 4, 2011 | Slide 82

FOXMAN-UN NP soutient l'identification des configurations complexes comme

Multipoints (Broadcast)

Point--multipoints

Confrence de voix

Les oprations suivantes ne font pas partie du NP mais peuvent tre effectues
avec le logiciel de base:

Rajout dun module

Rglage de paramtre l'intrieur d'un lment de rseau NE

Les ports trafic sont automatiquement librs par FOXMAN-UN NP

Gestion de configuration : Traitement du cheminement

Caractristiques principales (3) :

ABB Group
February 4, 2011 | Slide 83

Rapports qui vous permettent

de documenter votre rseau

une meilleure planification des activits d'entretien

une planification de largeur de bande efficace

Exemples de rapports, qui peuvent tre gnrs utilisant les filtres


configurables:

Rapport d'une application dfinie (circuit, cheminement ou


SNCs)

Rapport de donnes de client

Tous les circuits inclus dans une section spcifique


comprenant les informations de base du client

Circuits/cheminements pour un lment de rseau spcifique

Tous les circuits associs un client spcifique

Les rapports peuvent tre envoys une imprimante ou un fichier


de donnes peut tre gnr (en format HTML ou ASCII/CSV)

Gestion de performance

ABB Group
February 4, 2011 | Slide 84

Outil de collecte de donnes de performance pour la surveillance


de performance soutenant les intervalles de 15 minutes et/ou de
24 heures

Les donnes de performance inclues Bit Error, Errored Seconds


(ES), Severely Errored Seconds (SES) et plus

Dcrit dans les normes G.821, G.826 de lUTI-T

Les donnes de performance rassembles peuvent tre


exportes pour l'intgration dans un OSS (systme de support
d'opration)

Gestion de scurit

ABB Group
February 4, 2011 | Slide 85

L'utilisateur doit sauthentifier au niveau GUI (Explorateur de rseau &


Configurateur) aprs tre connect au serveur FOXMAN-UN.

Administration simplifie d'accs d'utilisateur : L'attribution d'un profil et


d'un domaine un utilisateur dfinit ses permissions d'accs

Le GUI de gestion de scurit est fourni dans le configurateur NEM

Carte de statut de synchronisation

La carte de synchronisation SDH/PDH permet l'affichage de l'tat courant de


synchronisation du rseau de transmission numrique pour des liens SDH et
PDH

Cela permet une identification rapide et efficace des les et boucles de


synchronisation

Flches noires

montre l'coulement normal de synchronisation

Flches rouges

indique une boucle d'horloge

Flches absentes

indique une le dhorloge ou de synchronisation

ABB Group
February 4, 2011 | Slide 86

Intgration dans un systme de gestion de niveau


suprieur
Higher Level Management Systems
HP OpenView
OS: Win, HP-UX

FOXMAN-UN

Avec la version R8B, une interface


Southbound SNMP est disponible,
permettant aussi une intgration
d'quipement de tiers capable de
grer SNMP

OS: Win

SNMP
Northbound IF

OS: RedHat Linux

3rd Party Equipment


with SNMP Agent

ABB Group
February 4, 2011 | Slide 87

Avec l'interface Northbound SNMP,


FOXMAN-UN peut exporter des
alarmes et l'information d'inventaire
vers un systme de gestion de niveau
suprieur tel que HP OpenView ou
Castlerock SNMPc

Castlerock SNMPc

SNMP
Southbound IF

FOX 515
Network Elements

Licence de Base et Options

ABB Group
February 4, 2011 | Slide 88

La licence de base inclut

Vue graphique du rseau

Gestion de section

Gestion d'objets trangers

Vue de synchronisation

Les licences optionnelles sont

Utilisateurs concourants additionnels

Systme de repli

Logiciel de gestion de rseau

Interface Northbound SNMP

Gestion de performance

Me r
ABB Group
February 4, 2011 | Slide 89

t
o
v
r
u
cie po

!
n
o
i
t
n
e
t
t
a
e
r

ABB Group
February 4, 2011 | Slide 90