Вы находитесь на странице: 1из 88

designs

DESIGNS
MS

single impeller - single stage

TS
twin impeller - single stage

MD

single impeller - double stage

TD

twin impeller - double stage

TT
triple impeller - three stage

GOR / GVR Design


GOR / GVR de s igns utilize a s tandard Ne ma
(or metric) electric motor that is directly coupled
to the blower shaft. This direct coupled design
allows the use of specialty motors that may be
required to meet a variety of electrical
requirements. For some models the vacuum /
pressure capabilities can be increased with the
GOR / GVR design.

Standard Design
The standard FPZ design is a direct drive
configuration, with a dynamically balanced
impeller fitted directly on the motor shaft. Fitted
motors are 2 pole, 1 and 3 phase, rated for
continuous service. Standard motors utilize
class F insulation, are suitable for use with a
variable speed drive (3 phase only), and are
tropicalized for corrosion resistance.

Standard Design

GVR Design

GOR Design

applications
APPLICATIONS
Thousands of FPZ blowers are working in a variety of
applications: from commercial to industrial installations,
in food processing to pharmaceuticals, from textiles to
aerospace, in medical applications to environmental.
Wherever efficiency and reliability are needed, FPZ
responds with the appropriate product solution

Advantages of side channel blowers


- Compact execution
- Simple concept
- Reduced maintenance costs
- Modular design
- Pulsation and oil free air

How Blowers Work


Blowers have an impeller blade mounted inside
a housing. As air passes the inlet port, impeller
blades draw air in and accelerate the air outward
and forward. As each impeller blade strikes it,
the air moves faster and faster. At the base of
the housing an air stripper diverts the air out of
the housing reducing the speed and then
increasing the pressure.

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

Table of Contents

SS1303

Page(s)
General Pressure and Vacuum Performance Curves

Max
Max
Pressure Vacuum
(In H2O) (In Hg.) Pressure Vacuum

K Series "MOR" Blowers - Direct Drive

Max
CFM

SCL K03-K06 MS
SCL K07-K12 MS
SCL K05-K06 TS
SCL K07-K12 TS
SCL K07R-12 MD
SCL K04-K06 TD
SCL K07-K12 TD

216
726
400
1410
336
222
716

132
211
85
110
300
180
225

9.6
11.1
6.3
8.1
14.7
11.8
13.2

6-7
8-9
10-11
12-13
14-15
16-17
18-19

40-41
42-43
44-45
46-47
48-49
50-51
52-53

39
35
98

52
120.5
201

3.5
8.1
11.1

20-21
22-23
24-25

54-55
56-57
58-59

9.6
10.3
7.8
10.3
14.7
13.2
17

26-27
28-29
30-31
32-33
34-35
36-37
38-39

60-61
62-63
64-65
66-67
68-69
70-71
72-73

Single Stage Blowers


Single Stage Blowers
Single Stage Blowers
Single Stage Blowers
Two Stage Blowers
Two Stage Blowers
Two Stage Blowers

06 / SH / DH Blowers Performance Data


SCL 06
SCL 10DL-15DH
SCL 20DH-40DH

Single Stage Blowers


Two Stage Blowers
Two Stage Blowers

K Series Direct Coupled - "GOR/GVR" configuration


SCL K03-K06 MS-GOR/GVR
SCL K07-K12 MS-GOR/GVR
SCL K05-K06 TS-GOR/GVR
SCL K07-K12 TS-GOR/GVR
SCL K07R- K12 MD GOR/GVR
SCL K07-K12 TD GOR/GVR
SCL K09-K11 TT GOR/GVR

Single Stage Blowers


Single Stage Blowers
Single Stage Blowers
Single Stage Blowers
Two Stage Blowers
Two Stage Blowers
Three Stage Blowers

216
726
400
1410
336
716
597

140
200
130
150
280
225
340

Values in above table based on 60 hz performance

Accessories
Installation Guide
VRL6-9
VRL6-9
VRL6HP / VRL8HP
CSL / CT
FS
VG-020-013
VS 6 / VS 8
VK / PK

General guide on how to install accessories.


Safety valve selection guide
Safety Valves
High pressure safety valves
Filters for vacuum applications.
Filter / Silencers for pressure applications
Dirty Filter Indicator
Flow Converting Devices for diverting air stream
Flange Connectors for safety valves and flexible hoses

74
75
76
77
78
79
80
81
82

CA / CK

Filter Manifolds and 90 Degree Manifold for K series blowers

83

VG / PG / CV / SS / IH
MF / TF / MP

Gauges, Check Valves, Silencers, and Sound Enclosures


Flexible Sleeves, Flanges, Sleeves

84
85

Technical
Single phase motor information
Three phase motor information
Airflow Through an Orifice
FPZ Pneumatic Range

86
87
88
89
Disclaimer

The information contained in this catalog is based on information that we believe to be correct. It is the users responsibility to determine the suitability of
the product for the application they are used in and the user assumes all risk and liability whatsoever in connection therewith.

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

Pressure Performance Curves

220
25

Legend
Installed power

200

25

K10-MS
15

10

Model

K10-TS

20

180
20

K09-MS

160

25

K08-MS

K07-MS

Static differential pressure ( In WG)

K11-MS

15

140
7 1/2

6 1/5

20

120

25

15

10
25

15

5 1/2

K12-MS

K04-MS

100

K07-TS

K06-MS

K09-TS

10

80

15

10

1
4

K05-MS

K03-MS

7 1/2

5 1/2

1 1/2

25

K10-TS

K11-TS

10

7 1/2

K08-TS

7 1/2

15

15

25

K12-TS

4
5 1/2

1/3

5 1/2

7 1/2

30

15

10

40

30

20

10

K05-TS

1/2

20

15

5 1/2

3/4

60

20

10

7 1/2

06

20

7 1/2

K06-TS

0
0

50

25

75

100

200

150

300

250

400

350

500

700

600

800

900

1000

1200

1400 1600

Capacity (cfm)

320

Legend

20

300

25

Installed power

15

25
20

280

Model

K10-TD
7 1/2

260

K10-MD

15

25

15

K09-MD

10

240

K11-MD

15

K08-MD

25

220

Static differential pressure ( In WG)

K07-MD
K07-TD

200
3

K12-MD

40DH

180

K09-TD

15

10

20

10

25
15

7 1/2

30DH

160

3
5 1/2

1 1/2

140

K06-TD

10

K08-TD

25

20

30

7 1/2

7 1/2

120

10

20DH

K10-TD

20

5 1/2

K04-TD

100

10

7 1/2

22

1/3

20
25

15

7 1/2

5 1/2

80

K11-TD

15

15

10

1/2 3/4

5 1/2

K12-TD
7 1/2

60
5 1/2

K05-TD

15DH

40

10DL
20

0
0

25

50

75

100

125

150

175

200

250

300
Capacity (cfm)

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Tolerance on given values 10% - data can change without prior notice.

350

400

450

500

550

600

650

700

800

FPZ, Inc

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

Vacuum Performance Curves

160
10

15

20

20

Legend

20

Installed power
25

15

140

K10-MS

7 1/2

6 1/5

Model
K10-TS

K11-MS

K09-MS
K08-MS
15

120

25

10

Static differential pressure ( In WG)

5 1/2

K12-MS

15

25

100

K07-MS
3

K06-MS

20

10
7 1/2

K04-MS

80

K05-MS

15

10

5 1/2

K07-TS

5 1/2

20

25

15
30
20

10

3/4

10

60
K05-TS

1 1/2

1/2

K11-TS

7 1/2
4

7 1/2

K10-TS

15

15

25

K12-TS

5 1/2

1/3

5 1/2

10

7 1/2

K09-TS

7 1/2

K03-MS

30

15

10

40

K08-TS

20

7 1/2

K06-TS

06

0
0

25

50

75

100

150

250

200

300

350

400

450

500

600

700

800

900

1000

1100

1200

1400 1600

Capacity (cfm)

220

Legend
Installed power

15

200

20
25

10

Model

25

15

K10-TD
7 1/2

180

15

10

K11-MD
7 1/2

Static differential pressure ( In WG)

5 1/2

K10-TD

K09-MD

10

40DH

25

20

7 1/2

K08-MD

K09-TD

K08-TD

10

30DH
120

20

K07-TD

5 1/2

140

15

K10-MD

10

160

25

20

30

7 1/2

1 1/2

100

K06-TD

15

10

3/4

K11-TD
10

7 1/2

K04-TD
80

20

15

5 1/2

1/2

K12-MD

7 1/2
5 1/2

20DH

1 1/2

K12-TD

1/3

60

7 1/2

5 1/2

K05-TD

K07-MD
40

15DH

20

10DL

25

50

75

100

150

200

250

300

Capacity (cfm)

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Tolerance on given values 10% - data can change without prior notice.

350

400

450

500

550

600

650

700

750

800

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K03 / K04 / K05 / K06


MS SERIES
SN 1874-8 1/2
H

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor

p1

OPTIONS

3x120
u

- Special voltages (IEC 38)


- Surface treatments

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

d
Accessory
o

Dimensions in inches.
Dimension for reference only.

Model

K03-MS
K04-MS
K05-MS
K06-MS

9.49
11.22
12.87
14.80

10.55
12.40
14.37
15.47

5.79
6.77
7.87
8.07

Model

1.69 9.06 8.07 11/4 NPT


1.93 10.04 8.86 11/2 NPT
2.13 12.60 10.24 2 NPT
2.13 12.80 11.42 2 NPT

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

G
I
f
e

3.39
4.02
4.72
4.92

0.39
0.47
0.59
0.59

Maximum
p ( In WG )
60 Hz
50 Hz
3500 rpm 2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm
3/4
1

64
95

p1

3.27 5.59 8.07


3.74 6.73 8.74
4.53 10.43 12.60
5.51 10.71 13.15

differential pressure

50 Hz
2900 rpm

0.71
0.71
0.71
0.71

2.95
2.76
3.86
3.35

0.16
0.16
0.16
0.16

M6
M6
M8
M8

5.51
6.89
7.87
9.45

0.47
0.71
0.75
0.75

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

60
77

62.0
62.3

60.0
60.3

10.43
11.97

24.30
26.50

80
100
-

64.8
65.0
65.2

62.8
63.0
-

11.65
13.78
13.78

36.40
43.00
49.60

K03-MS

52

43

3/4
1

K04-MS

98

81

1
2
3

1
2
-

58
85
120

52

70

70.5

68.5

13.20

51.80

K05-MS

156

129

3
4

3
4

90
128

110
120

70.8
71.1

68.8
69.1

13.20
14.40

58.40
67.20

50

65

73.0

71.0

13.54

68.70

K06-MS

216

179

75

95

73.3

71.3

14.17

71.65

110

140

73.6

71.6

6 1/5 (2)

132

73.9

14.17
14.45

77.60
77.60

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) No cURus motor

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - PRESSURE 7

SCL K03 / K04 / K05 / K06


MS SERIES
SN 1874-8 2/2

140
6 1/5
4

120

50 Hz

In WG

p psig

p psig

160

60 Hz

In WG

140

5 1/2

5 1/2

120
100
1
3

80
4

3/4

60

1 1/2

100

2
4

CAPACITY

80

1 1/2

2
3

60

3/4

40
40
1

1
20

0
100

K06-MS
K04-MS
K03-MS

40
1

140

200

Scfm

50 Hz

120

K06-MS
K05-MS

80

K04-MS

60
K03-MS

TEMPERATURE INCREASE

K06-MS
K04-MS

80
60

1
20

20

40

60

80

100

120

140 F

Hp

50 Hz

120
4

K05-MS
100

K06-MS
K04-MS

80
60
K03-MS
40

1
20
0

0
0

160

60 Hz

K05-MS

Hp

40

150

p psig

K03-MS
2

100

40

0
1

100
3

50

100

In WG

p psig

K06-MS

20

20
0

K05-MS

160

K05-MS

60

K04-MS

250 Scfm

60 Hz

80

K03-MS

In WG

200

140

100
3

150

p psig

50

In WG

p psig

20

K06-MS

0
0

K05-MS

ABSORBED POWER

K04-MS

In WG

K03-MS

0
0

20

40

60

80

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

100

120

140

160

180

200 F

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 / K12


MS SERIES
SN 1805-14 1/2
H

TECHNICAL CHARACTERISTICS
-

p1

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor

3x120
u

OPTIONS

- Special voltages (IEC 38)


- Surface treatments

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

Accessory

s
I

Dimensions in inches.
Dimension for reference only.

Model

p1

K07-MS
K08-MS
K09-MS
K10-MS
K11-MS
K12-MS

16.69
17.99
19.37
20.31
21.34
21.57

18.84
19.61
22.09
22.56
23.74
23.82

10.59
10.59
12.40
12.40
13.07
13.07

3.23
3.23
3.78
3.78
3.58
3.58

18.43
18.82
20.00
20.00
21.26
21.26

17.24
17.64
18.82
18.82
20.00
20.00

3 NPT
3 NPT
4 NPT
4 NPT
4 NPT
4 NPT

6.10
6.10
7.17
7.17
7.87
7.87

0.51
0.51
0.51
0.51
0.51
0.51

11.81
11.81
11.81
11.81
11.81
11.81

13.78
13.78
13.78
13.78
13.78
13.78

20.16
20.16
23.07
23.07
23.46
23.58

0.98
0.98
0.98
0.98
0.98
0.98

5.39
5.39
7.83
7.83
8.03
8.03

0.20
0.20
0.20
0.20
0.20
0.20

M8
M8
M8
M8
M8
M8

11.61
12.2
14.17
14.17
15.35
15.35

0.63
0.63
0.63
0.63
0.63
0.51

Model

Maximum
flow

Installed
power

differential pressure

Noise level
Lp dB (A)

Overall
dimensions

Scfm

Hp

Dp ( In WG )

(1)

60 Hz
3500 rpm

K07-MS

K08-MS

K09-MS

K10-MS

294

381

471

556

Maximum

Weight

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

243

4
5
7
10

4
5
7
10

50
75
130
181

63
86
138
161

78.7
79.0
79.3
79.6

76.7
77.0
77.3
77.6

15.45
15.45
18.37
18.37

103.00
107.10
145.70
154.50

316

5
7
10
15

5
7
10
15

40
68
115
181

52
90
125
181

79.7
80.0
80.3
80.6

77.7
78.0
78.3
78.6

15.45
18.37
18.37
19.15

115.70
154.30
163.10
184.00

390

7
10
15
20

7
10
15
20

50
80
140
181

63
95
155
181

80.2
80.5
81.0
81.3

78.2
78.5
79.0
79.3

18.84
18.84
19.63
23.74

166.50
175.10
196.20
269.00

460

7
10
15
20
25

7
10
15
20
25

36
64
120
167
211

51
80
135
191
201

80.1
80.5
81.0
81.4
81.6

78.1
78.5
79.0
79.4
79.6

18.84
18.84
19.63
23.74
24.61

170.90
179.50
200.60
273.40
298.70

10
15
20
25

40
82
125
162

53
97
141
201

82.0
82.4
82.7
85.6

80.0
80.4
80.7
83.6

19.04
19.83
23.94
24.81

194.90
216.00
288.80
313.10

15
20
25

52
85
140

90
130
160

82.9
83.2
86.1

80.9
81.2
84.1

19.95
24.06
24.92

223.70
296.50
320.80

K11-MS

650

539

10
15
20
25

K12-MS

726

602

15
20
25

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - PRESSURE

SCL K07 / K08 / K09 / K10 / K11 / K12


MS SERIES
SN 1805-14 2/2

25

7
10

180

15

20

CAPACITY

25

7 1/2
20
15
10

4
100

5 1/2

K10-MS

K12-MS

0
300

400

500

600

700

ABSORBED POWER

In WG
160
140

K11-MS
K10-MS

K09-MS

100

K12-MS

K07-MS

80
60

7
6

160

140

20

4
3

K11-MS

160
K10-MS

140
120

4
3
2

K07-MS

K09-MS

K08-MS

100
80
K12-MS

60
40

1
0

500

600

20
0

K08-MS

K10-MS

K07-MS

K12-MS
K09-MS

K11-MS

80
60
40
20
0
0

10

15

20

40

60

80

100

120

140

160

180

200 F

50 Hz

180
6

160

140

K11-MS
K10-MS

120
4
3
2

25 Hp

20

In WG

p psig

K08-MS

K09-MS

K07-MS

100
80
K12-MS

60
40

1
0

700 Scfm

50 Hz

240

In WG

p psig

400

100

Hp

60 Hz

180
6

25

300

120

0
15

200

180

0
10

100

240
8

K12-MS
K11-MS

K09-MS

0
0

20

240

K10-MS

K08-MS

800 Scfm

60 Hz

K08-MS

10

In WG

200

p psig

100

7 1/2

5 1/2

K07-MS

TEMPERATURE INCREASE

7 1/2

60

K11-MS

K09-MS

40
1

10

20

120

15

80

180

15

7 1/2

5 1/2

40

240
p psig

10

7 1/2

K08-MS

100

15

7 1/2

K07-MS

20

10

20

15
10

60

40

20

7 1/2

5 1/2

140

120

20

15

10

80

25
15

10

7 1/2

20

10

160

15

140
120

15

25

160

25

20

180
20

25

200

200
7

50 Hz

In WG

p psig

240

60 Hz

In WG

p psig

240

20
0
0

20

40

60

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120

140

160

180

200 F

10

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K05 / K06


TS SERIES
SN 1921-5 1/2
a

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor 3x120u

H
z

p1

t
b

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

c
d

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

Accessory

n
o

G
I
f
e

Dimensions in inches.
Dimension for reference only.

Model

p1

K05-TS

12.87 16.61 10.16 3.03 15.91 14.72

3 NPT

5.91

0.51 11.81 13.58 24.96 0.98 12.91 0.16

M8

7.87

0.75

K06-TS

14.80 17.72 10.31 2.95 15.91 14.72

3 NPT

6.10

0.51 11.81 13.58 26.06 0.98 13.19 0.16

M8

9.45

0.75

Model

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K05-TS

290

241

K06-TS

400

331

60 Hz
3500 rpm
3
4
5
5
7
10

50 Hz
2900 rpm
3
4
5
5
7
10

Maximum
differential pressure
p ( In WG )
60 Hz
50 Hz
3500 rpm 2900 rpm
45
30
70
46
100
72
55
36
65
55
93
85

Noise level
Lp dB (A)

Overall
dimensions

(1)

60 Hz
3500 rpm
72.0
73.5
75.5
77.2
77.5
77.8

50 Hz
2900 rpm
70.0
71.5
73.5
75.2
75.5
75.8

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Inches
17.45
18.64
18.64
18.98
22.60
22.60

Weight

Lbs
85.98
89.29
93.70
104.72
141.09
149.91

REGENERATIVE BLOWERS - PRESSURE

SCL K05 / K06


TS SERIES
SN 1921-5 2/2
120

p psig

p psig

60 Hz

10

50 Hz

In WG

100
3,5

100

1/2

80
10
5

1/2

2,5

CAPACITY

80
60
2

1/2

1,5

4
7

1/2

60
2

1/2

40
5

1/2

40

K06-TS

K06-TS

K05-TS

K05-TS

20
20
0,5

0
400

100

80

60
2
K06-TS
40
K05-TS
1
20

100

K06-TS
K05-TS

60
2
40

1
20
0,5
0

20

40

60

80 F

400 Scfm

K06-TS

60
K05-TS

0
1

10 Hp

50 Hz

K06-TS

K05-TS

80

60

40
1
20

0
0

350

120

2,5

1,5

300

50 Hz

60 Hz

80

250

80

10 Hp

p psig

TEMPERATURE INCREASE

In WG

p psig

3,5

200

20

0
1

150

0
0

100

40

0,5
0

50

120

60 Hz

2,5

1,5

500 Scfm

In WG

300

In WG

200

p psig

3,5

100

In WG

p psig

ABSORBED POWER

0
0

20

40

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

60

80

100

120

140 F

11

12

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 / K12


TS SERIES
SN 1822-11 ss

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor
G1/8 female thread on both suction
and discharge silencer port flanges

OPTIONS

For model K09/K10/


K11/K12-TS only
j
Int.k

For model K11-K12-TS Hp 30 60Hz only

H
z

p1
G

3x120u

- Special voltages (IEC 38)


- Surface treatments

G 1/8

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

d
Accessory

m
n

G
I
f
e

Dimensions in inches.
Dimension for reference only.

Model

K07-TS
K08-TS
K09-TS
K10-TS
K11-TS
K12-TS

16.69
18.03
19.37
20.31
21.26
21.57

20.91
21.57
24.02
24.53
25.59
25.66

12.56
12.56
14.37
14.37
14.96
14.96

3.86
3.86
4.41
4.41
4.17
4.17

18.43
18.82
20.00
20.00
21.26
21.26

17.24
17.64
18.82
18.82
20.08
20.08

4NPT
4NPT
5.12
5.12
5.12
5.12

7.17
7.17
8.27
8.27
8.98
8.98

M16
M16
M16
M16

8.27
8.27
8.27
8.27

0.51
0.51
0.51
0.51
0.51
0.51

9.84
9.84
9.84
9.84
9.84
9.84

21.65
21.65
21.65
21.65
21.65
21.65

Model

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K07-TS

588

487

K08-TS

715

592

K09-TS

941

780

K10-TS

1093

906

K11-TS

1254

1039

K12-TS

1410

1168

60 Hz
3500 rpm
7
10
15
7
10
15
20
25
20
25
25
(2)
30
(2)
30

50 Hz
2900 rpm
7
10
15
7
10
15
20
25
20
25
25
(2)
30
(2)
30

Maximum
differential pressure
p ( In WG )
60 Hz
50 Hz
3500 rpm 2900 rpm
36
48
60
71
110
121
18
30
37
50
75
87
80
90
110
120
65
75
80
95
50
69
70
90
45
80

p1

31.57 0.98 11.77 0.20


31.57 0.98 11.77 0.20
33.46
12.40 0.20
33.46
12.40 0.20
34.25
12.60 0.20
34.37
12.60 0.20

M8
M8
M8
M8
M8
M8

11.61
12.20
14.17
14.17
15.35
15.35

0.63
0.63
0.63
0.63
0.63
0.63

Noise level
Lp dB (A)

Overall
dimensions

(1)

60 Hz
3500 rpm
83.9
84.2
84.8
80.8
80.9
83.3
85.0
87.0
88.1
88.4
89.4
90.0
90.6

50 Hz
2900 rpm
81.9
82.2
82.8
78.8
78.9
81.3
83.0
85.0
86.1
86.4
87.4
88.0
88.6

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) K11-K12-TS Hp 30 vertical assembly only.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Inches
23.76
23.76
24.55
23.76
23.76
24.55
29.92
30.79
29.92
30.79
31.38
31.38
31.50

Weight
Lbs
197.31
206.13
223.77
205.47
214.29
231.92
350.53
383.60
354.94
388.01
429.02
434.53
436.75

REGENERATIVE BLOWERS - PRESSURE

SCL K07 / K08 / K09 / K10 / K11 / K12


TS SERIES

15

p psig

60 Hz
25

140

50 Hz

In WG

120
In WG

p psig

SN 1822-11ss

15

120

100

25

100
80

20

25

25

15

CAPACITY

15
30
20

60

10

2
25

80

30
20
10

25

60
2

30

10

7 1/2

40

10

7 1/2

40

7 1/2

1
K07-TS

7 1/2

K09-TS

K08-TS

K10-TS

0
600

800

1000

1200

1400

80

60

K10-TS

K11-TS

K09-TS
K08-TS

40

K12-TS

K07-TS

10 12

14 16

18 20

22 24 26 28

30

800

1000

1200 Scfm

50 Hz

80

K11-TS

K10-TS
K09-TS

60

K12-TS

K08-TS
K07-TS

TEMPERATURE INCREASE

K07-TS

K09-TS

K08-TS

60

60 Hz

80

K10-TS
K11-TS
K12-TS

1
20

0
20

40

60

80

100 F

10

12

14

16

18

20

22

24

26

Hp

50 Hz
K09-TS
K10-TS

100
3

140

K07-TS

K11-TS
K12-TS

80

K08-TS

60
40

1
20
0

Hp

p psig

40

600

0
2

In WG

p psig

400

140

40

120

K12-TS

20

K10-TS

100

20

200

In WG

ABSORBED POWER

60 Hz

In WG

p psig

120
4

K11-TS

1600 Scfm

p psig

400

K09-TS
K08-TS

K12-TS

0
200

K07-TS

20

K11-TS

In WG

20

30

20

0
0

20

40

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

60

80

100

120 F

13

14

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07R / K08R / K09 / K10 / K11 / K12


MD SERIES
SN 1848-8 1/2
p1

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor

t
3x120
u

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

b
c

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

d
G

m
n
o

I
f

Dimensions in inches.
Dimension for reference only.

Model

p1

K07R-MD
K08R-MD
K09-MD
K10-MD
K11-MD
K12-MD

16.69
17.99
19.37
20.31
21.35
21.57

18.94
19.61
22.09
22.56
23.74
23.85

10.59
10.59
12.40
12.40
13.07
13.07

3.23
3.23
3.78
3.78
3.58
3.58

18.43
18.82
20.00
20.00
21.18
21.18

17.24
17.64
18.82
18.82
20.00
20.00

2 NPT
2 NPT
4 NPT
4 NPT
4 NPT
4 NPT

6.10
6.10
7.17
7.17
7.87
7.87

0.51
0.51
0.51
0.51
0.51
0.51

11.81
11.81
11.81
11.81
11.81
11.81

13.78
13.78
13.78
13.78
13.78
13.78

16.46
16.46
25.35
25.35
25.75
25.87

0.71
0.71
0.98
0.98
0.98
0.98

1.70
1.70
10.12
10.12
10.31
10.31

0.20
0.20
0.20
0.20
0.20
0.20

M8
M8
M8
M8
M8
M8

11.61
12.20
14.17
14.17
15.35
15.35

0.63
0.63
0.63
0.63
0.63
0.52

Model

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

K07R-MD

K08R-MD

K09-MD

K10-MD

K11-MD

K12-MD

129

168

221

275

306

336

50 Hz
2900 rpm

107

139

183

228

254

278

Maximum
differential pressure

60 Hz
3500 rpm

50 Hz
2900 rpm

p ( In WG )
60 Hz
50 Hz
3500 rpm 2900 rpm
68

87

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

73.5

71.5

16.14

101.40

110

128

74.0

72.0

16.14

103.60

150

170

74.5

72.5

16.14

111.50

260

260

75.0

73.0

17.52

134.50

85

110

76.2

74.2

16.14

116.90

162

185

76.6

74.6

17.52

140.00

10

10

240

260

77.0

75.0

17.52

151.00

15

260

77.3

17.52

173.00

54

78

76.9

74.9

16.54

144.40

120

143

78.0

76.0

17.95

167.60

10

10

190

210

79.5

77.5

17.95

178.60

15

15

290

290

80.5

78.5

19.29

200.60

85

110

79.9

77.9

17.91

170.90

10

10

140

165

80.3

78.3

17.91

181.90

15

15

245

270

81.4

79.4

19.29

203.90

20

20

300

300

81.7

79.7

22.97

270.00

10

10

100

125

81.1

79.1

18.11

211.60

15

15

190

220

81.4

79.4

19.49

232.60

20

20

280

300

81.7

79.7

25

300

82.0

23.23
23.23

287.20
353.30

15

15

100

180

82.3

80.3

19.61

240.30

20

20

180

260

82.6

80.6

25

250

82.9

23.42
23.42

295.00
361.00

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - PRESSURE 15

SCL K07R / K08R / K09 / K10 / K11 / K12


MD SERIES
60 Hz

20

12

25

11

340

50 Hz

In WG

11

340

p psig

12

In WG

p psig

SN 1848-8 2/2

20

10
9

280

20

260

7 1/2

10

15

25

15

10

240
8

20

15

15

280
15
7 1/2

260

20

10

240
8

220

220

15
10

15
20

7 1/2
5 1/2

120

7 1/2

100
80

20

K07R-MD

10
9
8
7
6
5
4
3
2
1
0

10
9
8
7
6
5
4
3
2
1
0

200

300

400

260
240
220
200
180
160
140
120
100
80
60
40
20
0

K08R-MD
K07R-MD

K11-MD

K09-MD

11
10
9
8
7
6
5
4
3
2
1
0

10

12

14

16

18

20

340

22

K10-MD

K09-MD
K08R-MD
K12-MD

11
10
9
8
7
6
5
4
3
2
1
0

20

40

60

80

100

120

140

160

5 1/2

60

180

200

K08R-MD

20

K10-MD

K07R-MD

K09-MD

K12-MD
K11-MD

0
100

200

300 Scfm

340

50 Hz

260
240
220
200
180
160
140
120
100
80
60
40
20
0

K08R-MD
K07R-MD

12

60 Hz

K07R-MD

7 1/2

80

24 Hp

K11-MD

260
240
220
200
180
160
140
120
100
80
60
40
20
0

10
5 1/2

12

K12-MD

K10-MD

120

Scfm

60 Hz

In WG

p psig

11

100

340

12

K11-MD

K09-MD

7 1/2

140

40

K12-MD

In WG

p psig

11

K10-MD

K08R-MD

12

5 1/2

40
1

60

10

100

15

p psig

10
7 1/2

5 1/2

ABSORBED POWER

15

5 1/2

160
5

TEMPERATURE INCRESASE

140

10

7 1/2

180
6

In WG

160
5

200

K11-MD

K09-MD

K12-MD

K10-MD

10

12

14

340

16

18

Hp

200

50 Hz

In WG

CAPACITY

10

180

p psig

200

K11-MD

260
240
220
200
180
160
140
120
100
80
60
40
20
0

K10-MD

K07R-MD
K08R-MD

K12-MD

K09-MD

20

40

60

80

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

100

120

140

160

180

16

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K04 / K05 / K06


TD SERIES
SN 1931-5 1/2
y

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor

I1

45

H
p1

z
t

OPTIONS
b

- Special voltages (IEC 38)


- Surface treatments
-

d1

ACCESSORIES

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

3x120 u

x
p2

m
r

n
r1

G
I2

q
f
e

o
Dimensions in inches.
Dimension for reference only.

Model

d1

I1

I2

p1

p2

r1

K04-TD

11.22 12.40 6.77 1.93 4.76 10.04 8.86 1 NPT 4.84 2.01 0.47 3.74 6.73 12.44 10.00 0.71 2.76 0.59 0.16 M6

6.89 7.40 8.43 6.81 0.71

K05-TD

12.87 14.37 7.87 2.13 5.51 12.60 10.24 2 NPT 5.71 2.36 0.59 4.53 10.43 16.85 13.39 0.71 3.86 1.57 0.16 M8

7.87 11.26 11.54 8.11 0.75

K06-TD

14.80 16.54 9.13 2.32 6.69 12.80 11.42 2 NPT 5.94 2.87 0.59 5.51 10.43 19.92 13.94 0.71 5.35 0.75 0.16 M8

9.45 11.26 12.13 8.27 0.75

Model

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K04-TD

99

82

K05-TD

153

127

K06-TD

222

184

60 Hz
3500 rpm

50 Hz
2900 rpm

2
3
3
4
5
5
7
10

2
3
3
4
5
5
7
10

Maximum
differential pressure
p ( In WG )
60 Hz
50 Hz
3500 rpm 2900 rpm
95
70
160
130
95
70
135
105
190
150
120
80
140
125
200
180

Noise level
Lp dB (A)

Overall
dimensions

(1)

60 Hz
3500 rpm
71.0
72.0
73.0
74.5
76.0
75.0
76.0
77.0

50 Hz
2900 rpm
69.0
70.0
71.0
72.5
74.0
73.0
74.0
75.0

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Inches
17.26
17.26
17.45
18.64
18.64
18.98
22.60
22.60

Weight

Lbs
62.83
69.44
84.88
88.18
92.59
103.62
139.99
148.81

REGENERATIVE BLOWERS - PRESSURE

SCL K04 / K05 / K06


TD SERIES
SN 1931-5 1/2
60 Hz
p psig

In WG

7
p psig

240

10

160
5

1/3

1/2

180

1/2

140

6
3
1/2

CAPACITY

120
4
4

100

200

50 Hz

In WG

200

80

5
2

160

140

1/4

4
5

120

1/2

4
100

1/2

80

60
2
2

60

40
40
1

K04-TD

K05-TD

K04-TD

K06-TD

20

200

160
140
K06-TD
120
K05-TD
100

3
2

K04-TD

80
60
40

6
5

200

K06-TD

160
140

K05-TD

120
4

K04-TD
100

3
2

80
60
40

1
0

20
0

20

40

60

80

100

120

140

160

180 F

K06-TD
K05-TD

140
K04-TD

120
100

80

60
40
20
0
0

240
8

10

11 Hp

50 Hz
K06-TD

7
180
6

160

140

K05-TD
K04-TD

120
4

100

80

60
40

1
0

200 Scfm

50 Hz

160

10 Hp

60 Hz

In WG

p psig

0
2

150

180
6

0
1

100

50

240
8

20

TEMPERATURE INCREASE

60 Hz

250 Scfm

In WG

200

In WG

150

ABSORBED POWER

100

In WG

p psig

50

p psig

K06-TD

20

p psig

K05-TD

20
0
0

20

40

60

Curves refer to air at 68F temperature and 29.92 I n Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120

140

160

180 F

17

18

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 / K12


TD SERIES
SN 1830-10 1/2
y

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor
G1/8 female thread on both suction
and discharge silencer port flanges

G 1/8

45

I1

H
p1

z
3x120
u

w
t

OPTIONS

- Special voltages (IEC 38)


- Surface treatments

ACCESSORIES
-

d1

G 1/8

x
p2

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

m
r

G
I2

f
e

Dimensions in inches.
Dimension for reference only.

Model
K07-TD
K08-TD
K09-TD
K10-TD
K11-TD
K12-TD

Model

d1

I1

I2

p1

p2

16.69 18.94 10.59 3.23 7.56 18.43 17.24 3NPT 7.36 3.05 0.51 11.81 13.78 25.55 15.43 0.98 5.39 0.20

M8 11.61 18.94 12.56 10.24 0.63

17.99 19.61 10.59 3.23 7.56 18.82 17.64 3NPT 7.36 3.05 0.51 11.81 13.78 25.55 15.43 0.98 5.39 0.20

M8 12.20 18.94 12.56 10.24 0.63

19.37 22.09 12.4 3.78 8.86 20.00 18.82 4NPT 8.66 3.58 0.51 11.81 13.78 29.33 17.91 0.98 7.83 0.20

M8 14.17 21.89 14.65 11.89 0.63

20.31 22.56 12.4 3.78 8.86 20.00 18.82 4NPT 8.66 3.58 0.51 11.81 13.78 29.33 17.91 0.98 7.83 0.20

M8 14.17 21.89 14.65 11.89 0.63

21.26 23.70 13.07 3.54 9.13 21.18 20.00 4NPT 9.53 3.94 0.51 11.81 13.78 30.12 18.50 0.98 8.03 0.20

M8 15.35 21.89 15.24 12.76 0.63

21.57 23.81 13.07 3.54 9.13 21.18 20.00 4NPT 9.53 3.94 0.51 11.81 13.78 30.23 18.50 0.98 8.03 0.20

M8 15.35 21.89 15.24 12.76 0.63

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K07-TD

296

245

K08-TD

368

305

K09-TD

467

387

K10-TD

571

473

K11-TD

642

532

K12-TD

716

593

60 Hz
3500 rpm
7
10
15
7
10
15
15
20
25
15
20
25
20
25
25
30

50 Hz
2900 rpm
7
10
15
7
10
15
15
20
25
15
20
25
20
25
25
30

Maximum
differential pressure

p ( In WG )

60 Hz
3500 rpm
90
135
225
58
95
170
105
160
220
85
130
180
90
130
85
120

50 Hz
2900 rpm
105
150
241
75
110
185
125
180
240
100
150
200
115
155
140
190

Noise level
Lp dB (A)

Overall
dimensions

(1)

60 Hz
3500 rpm
80.9
81.2
81.8
80.1
80.4
81.5
82.7
83.0
83.3
86.6
86.9
87.2
87.4
87.9
88.2
88.7

50 Hz
2900 rpm
78.9
79.2
79.8
78.1
78.4
79.5
80.7
81.0
81.3
84.6
84.9
85.2
85.4
85.9
86.2
86.7

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Inches
23.76
23.76
24.55
23.76
23.76
24.55
25.81
29.92
30.79
25.81
29.92
30.79
31.38
31.38
31.50
31.50

Weight

Lbs
194.00
202.82
220.46
202.16
210.98
228.62
222.66
347.22
380.29
271.17
351.63
384.70
392.64
425.71
423.50
429.00

REGENERATIVE BLOWERS - PRESSURE

SCL K07 / K08 / K09 / K10 / K11 / K12


TD SERIES
SN 1830-10 2/2

220

10

9
15

280

50 Hz

In WG

60 Hz

p psig

In WG

p psig

260
9

15

240

25

200

25

220

10
25
30

15

100

15

7 1/2

2
K08-TD
K07-TD

400

500

600

700

800

60

K09-TD

K11-TD

K10-TD

K08-TD

K12-TD

15

20

25

30

K10-TD

140

K08-TD

120

80

60

300

400

500

600

Scfm

700

50 Hz

K07-TD

120

K09-TD

K08-TD

100

80

60

K11-TD

K10-TD

K12-TD

K11-TD
K07-TD
K12-TD

40
20
20

40

60

80

100

120

0
0

10

220

140 F

10

5
4

25

20

30

Hp

50 Hz

200
K09-TD

180
6

15

280

160

K10-TD

140

K08-TD

K11-TD

120

K07-TD

100

80

60

K12-TD

40
1
0

0
0

20

Hp

K09-TD

160

140

In WG

10

60 Hz

100

160

5
4

p psig

In WG

p psig

180

200

40

260

200

100

180

K11-TD

200

220

20

TEMPERATURE INCREASE

K09-TD

280

40
1

K07-TD

10

ABSORBED POWER

K07-TD

100
80

K12-TD

K10-TD

Scfm

60 Hz

120

K08-TD

In WG

300

p psig

200

180

60

20

200

7 1/2

K11-TD

In WG

p psig

K09-TD

260

140

80

100

160

15

K12-TD

K10-TD

20

7 1/2

40

20

15
10

25

25

100

80

40

140
120

20

25

20

10

10

60

160

7 1/2

CAPACITY

140
120

20

20

20

30
15

180

160

25

15

200

25

180

20
0
0

20

40

60

Curves refer to air at 68F temperature and 29.92 I n Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120

140

160

180 F

19

20

REGENERATIVE BLOWERS - PRESSURE

FPZ, Inc

SCL 06
06 SERIES

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SN 2673-0 1/2

STANDARD FEATURES
- Low weight cast aluminum construction.
- Quiet operation with integral inlet and
outlet muffling.
- Recognized TEFC - cURus motor.
- High efficiency / low noise impeller
design.
- No lubrication / maintenance required.
H
- Allowed ambient: +5 F to +104 F.
- Mountable in any plane.

1NPT
3.15
0.59 1.38

P version

0.43

2.95

4.13
7.10

OPTIONS
- Special voltages.
- Surface treatment or plating.
- Gas tight sealing.
- Special designs available.

7.6
8.7

M5

1.06

ACCESSORIES
- Inlet and/or inline filters.
- Additional inlet/outlet silencers.
- Safety valves.
- Flow converting devices.
- Optionals connectors

8.6

4.56
4.37
3.38

4.64

5.35 DIA
M5
Dimensions in inches.
Dimension for reference only.

Model

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm
06

39

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

32

1/3
1/2

1/2

Maximum
differential pressure
p ( In WG)
60 Hz
50 Hz
3500 rpm 2900 rpm

36
52

36

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

58.7
59.0

58.0

10.60
10.60

18.30
18.50

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - PRESSURE 21

SCL 06
06 SERIES
SN 2673-0 2/2
50 Hz

In WG

p psig

2.0

40

60 Hz

In WG

p psig

60

1/2

1/2

50
30
1.5

1.0
40

CAPACITY

1/3

30
1.0

20

0.5

20

10

0.5
10

0
20

30

40

40

1,0

30

20
0,5
10

0.2

0.3

40

30
1,0
20
0,5
10

0.5
10

10

20

30

40

50

60

70

80

90

0
0

1.0

0.05

0 .1

0.15

0.2

100 F

0.3 Hp

0.25

50 Hz

30

20
0.5
10

0
0

50 Hz

40

60 Hz

TEMPERATURE INCREASE

1.5

40 Scfm

20

Hp

In WG

p psig

60
2.0

0.5

0.4

30

30

0
0.1

20

1.0

0
0

10

In WG

1.5

40

60 Hz

ABSORBED POWER

In WG

p psig

60
2.0

Scfm

In WG

10

p psig

p psig

0
0

10

20

30

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

40

50

60

70

80 F

22

REGENERATIVE BLOWERS - PRESSURE

FPZ, Inc

SCL 10DL / 15DH


DH SERIES

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SN 2197-2 1/2

STANDARD FEATURES
- Low weight cast aluminum construction.
- Quiet operation with integral inlet and outlet
muffling.
- Recognized TEFC - cURus motor.
- High efficiency / low noise impeller design.
- No lubrication / maintenance required.
- Allowed ambient: +5 F to +104 F.
- Mountable in any plane.

OPTIONS
- Remote drive models (belt or coupling).
- Special voltages.
- Surface treatment or plating.
- Gas tight sealing.
- Special designs available.

n
o
H

ACCESSORIES
- Inlet and/or inline filters.
- Additional inlet/outlet silencers.
- Safety valves.
- Flow converting devices.
- Optionals connectors

s
f
e

Dimensions in inches.
Dimension for reference only.

Model

10DL

8.66

15DH

9.84

Model

10.08

9.06

0.91

8.27

7.09

1/2" NPT

2.28

0.35

4.72

5.67

3.54

0.10

11.26

10.16

1.18

8.27

7.09

3/4" NPT

2.52

0.35

4.72

5.67

4.72

0.10

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

Maximum
differential pressure

p ( In WG)

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

1/3
1/2

60
96

65
73

63.7
64.0

61.7
62.0

12.20
12.76

21.80
23.50

3/4
1

98
120.5

105
120.5

63.7
64.0

61.7
62.0

14.25
15.75

32.50
40.00

10DL

21

18

1/3
1/2

15DH

35

29

3/4
1

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - PRESSURE

SCL 10DL / 15DH


DH SERIES
SN 2197-2 2/2
p psig

60 Hz

140

50 Hz

In WG

140
In WG

p psig

120

120

4
3/4

100

80

1/3

60

CAPACITY

100

3/4

1/2

80
1/2
1/3

60

40

40

15DH
20

15DH
20

10DL

40 Scfm

60 Hz

10DL

15DH

80
60
40

0,6

0,8

140

15DH

10DL

60

10DL

80
60
40
20

20

40

60

80

100 F

0,2

0,4

0,6

0,8

140

1 Hp

50 Hz
15DH

100
3

80
10DL

60
40

1
20
0

0
0

0
0

60 Hz
15DH

50 Hz

80

1 Hp

p psig

0,4

TEMPERATURE INCREASE

140

40

0
0,2

100
3

40 Scfm

30

In WG

p psig

20

20

10

100

20
0

In WG

140

100
3

30

In WG

20

In WG

p psig

10

p psig

ABSORBED POWER

10DL

0
0

20

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

40

60

80

100 F

23

24

REGENERATIVE BLOWERS - PRESSURE

FPZ, Inc

SCL 20DH / 30DH / 40DH


DH SERIES

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SN 2464-2 1/2

STANDARD FEATURES
- Low weight cast aluminum construction.
- Quiet operation with integral inlet and outlet
muffling.
- Recognized TEFC - cURus motor.
- High efficiency / low noise impeller design.
- No lubrication / maintenance required.
- Allowed ambient: +5 F to +104 F.
- Mountable in any plane.
OPTIONS
- Remote drive models (belt or coupling).
- Special voltages.
- Surface treatment or plating.
- Gas tight sealing.
- Special designs available.

3x120
u

c
d

ACCESSORIES
- Inlet and/or inline filters.
- Additional inlet/outlet silencers.
- Safety valves.
- Flow converting devices.
- Optionals connectors

s
l

f
q

p1

Dimensions in inches.
Dimension for reference only.

Model
20DH
30DH
40DH

Model

20DH

11.42 12.20 6.50


12.60 13.66 7.36
13.78 14.57 7.68

1.77 9.06 8.27


2.09 10.63 9.64
2.09 10.63 9.65

Maximum
flow

Installed
power

Scfm

Hp

1 NPT
1 NPT
1 NPT

3.54
4.13
4.13

0.39
0.39
0.39

5.90
7.28
7.28

Maximum
differential pressure

p ( In WG)

p1

7.67 13.98 0.71


9.25 16.54 0.71
9.25 17.32 0.71

1.77
2.17
2.17

0.79
0.79
0.79

M6
M6
M8

5.91
7.09
8.86

0.31
0.67
-

Noise level
Lp dB (A)

Overall
dimensions

(1)

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

48

42

143

140

68.0

65.0

13.78

47.30

2
-

140
191

161
-

69.7
70.0

67.7
68.0

15.36
15.36

58.30
64.90

3
4

151
201

156
201

74.7
75.0

71.7
72.0

16.93
16.93

75.00
83.80

30DH

70

61

40DH

98

85

3
4

50 Hz
2900 rpm

60 Hz
3500 rpm

Weight

60 Hz
3500 rpm

2
3

60 Hz
3500 rpm

50 Hz
2900 rpm

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Inches

Lbs

REGENERATIVE BLOWERS - PRESSURE 25

SCL 20DH / 30DH / 40DH


DH SERIES
SN 2464-2 2/2

180

50 Hz

In WG

p psig

220

60 Hz

In WG

p psig

220

180

6
160

160

120
4
100

60

40DH

40

0
40

60

80

100

5
4

2
1
0

40DH

140
120
20DH

80
60
40

0.5

1.5

2.5

40DH

140
20DH

80
60
40
20
20

40

60

80

100

120

140

160

80

180 F

100 Scfm

50 Hz

20DH

140

40DH

30DH

120

80
60
40
20
0
0

0.5

1 .5

2 .5

3 .5

4 Hp

50 Hz
40DH

6
160
5
4

30DH

140
120
20DH

100
3
2
1
0

0
0

60

220

30DH

120

40

160

4 Hp

In WG

p psig

60 Hz

100

3.5

20

100
3

160

220

20
0

p psig

30DH

160

100
3

220

ABSORBED POWER

20DH

120 Scfm

60 Hz

In WG

p psig

220
7

30DH

20

0
20

40DH

20DH

60

In WG

20

80

40

30DH

100

p psig

120
4

80

TEMPERATURE INCREASE

1 1/2

140

In WG

140

CAPACITY

1 1/2

80
60
40
20
0
0

20

40

60

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120

140

160

180 F

26

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K03 / K04 / K05 / K06


MS SERIES - GOR/GVR RANGE
SN 2580-0 1/2

TECHNICAL CHARACTERISTICS

GOR Range

- Aluminium alloy construction


- Smooth operation
- High efficiency impeller
- Maintenance free
- Mountable in any position

GVR Range

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
- Inlet and/or inline filters
- Additional inlet/outlet silencers
- Safety valves
- Flow converting device
- Optional connectors

For dimensions, please refer to drw:


- GOR range: SI 1852
- GVR range: SI 1946

Model

SCL Kxx-MS GOR-A

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K03-MS

52

43

3/4
1

K04-MS

98

81

1
2
3

K05-MS

156

129

216

179

Maximum
Size

differential pressure

Dp ( In WG )

Noise level
Lp dB (A)
(1)

Weight
(2)

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Lbs
GOR GVR

NEMA 56C
NEMA 56C

64
80

60

62.0
62.3

60.0

22.00 17.60

NEMA 56C
NEMA 56C
NEMA 56C

58
85
100

NEMA 143-5TC

52

70

70.5

68.5

NEMA 143-5TC
NEMA 182-4TC

90

110

70.8

68.8

NEMA 182-4TC

130

120

71.1

69.1

50

65

73.0

71.0

3
K06-MS

SCL Kxx-MS GOR-C

NEMA 143-5TC
NEMA 182-4TC

80
90

64.8
65.0
65.2

62.8
63.0

NEMA 182-4TC

85

110

73.6

71.6

NEMA 182-4TC

140

135

73.9

71.9

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

27.60 22.00

35.00 28.00
34.50 27.00
46.00 38.40
40.80 38.00

REGENERATIVE BLOWERS - PRESSURE

SCL K03 / K04 / K05 / K06


MS SERIES - GOR/GVR RANGE
SN 2580-0 2/2
160

7 1/2

140

50 Hz

In WG

p psig

In WG

p psig
5

160

60 Hz

140
7 1/2

120

120

CAPACITY

3
5

2
1

80

3/4

60

40
1
K03-MS

K04-MS

K05-MS

20

K06-MS

0
50

100

150

200

ABSORBED POWER

120
4

K06-MS
100
K05-MS
80
K04-MS
60
K03-MS
40

Scfm

50 Hz

120

K06-MS
K05-MS

80

K04-MS

60
K03-MS

K05-MS

100
K04-MS

80
K03-MS

60

40
1
20

20

40

60

80

100

120

140 F

Hp

50 Hz

120
4
100
3

K05-MS

K06-MS

80

K04-MS

60
K03-MS
40

1
20
0

0
0

160

TEMPERATURE INCREASE

K06-MS

Hp

60 Hz

In WG

p psig

200

In WG

p psig

120

150

0
1

100

40

160

K06-MS

20

50

100

20
0

K05-MS

160

60 Hz

In WG

p psig

160

K04-MS

250 Scfm

p psig

K03-MS

In WG

20

3/4

1 1/2

60

40

80

1 1/2

100

100

0
0

20

40

60

80

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

100

120

140

160

180

200 F

27

28

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 / K12


MS SERIES - GOR/GVR RANGE
SN 2134-2S1/2

GVR Range

GOR Range

TECHNICAL
CHARACTERISTICS
Aluminium alloy construction
Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
-

SCL Kxx-MS GOR-C

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

For dimensions, please refer to drw:


GOR range: SI 1873
GVR range: SI 1920

Model

K07-MS

Maximum
flow
Scfm
60 Hz
3500 rpm

50 Hz
2900 rpm

294

243

SCL Kxx-MS GOR-A

Installed
power
Hp

381

316

471

390

539

726

602

79.0

77.0

110.50

77.3

110.50
110.50

NEMA 182-4TC
NEMA 182-4TC

38

52

79.7

77.7

68

90

80.0

78.0

115

125

80.3

78.3

170

160

80.6

78.6

NEMA 213-5TC
NEMA 213-5TC
NEMA 254-6TC

140

79.3
79.6

Lbs

110.50
127.00
127.00
127.00
127.00
127.00
130.60

NEMA 182-4TC
NEMA 213-5TC

50

63

80.2

78.2

133.40
133.40

10

NEMA 213-5TC

80

95

80.5

78.5

133.40

140

155

81.0

79.0

180

170

81.3

79.3

30

50

80.1

78.1

60

80

80.5

78.5

110

135

81.0

79.0

15

NEMA 213-5TC
NEMA 254-6TC
NEMA 254-6TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 254-6TC

137.00
137.00
147.30
147.30
147.30
147.30
151.00

NEMA 254-6TC

160

25

NEMA 284-6TSC

200

10

NEMA 213-5TC
NEMA 213-5TC

40

53

82.0

80.0

80

97

82.4

80.4

140

82.7

80.7

176.40

83.6

170.00
170.00

NEMA 254-6TC

190

81.4

133.40

20

81.6

79.4

20

NEMA 254-6TC

125

25
30

NEMA 284-6TSC
NEMA 284-6TSC

160
200

190

85.6
86.0

52

90

82.9

80.9

85
120

130

83.2
86.1

81.2

170

86.5

84.1

15
K12MS

86

15
650

70

170

10

K11-MS

50 Hz
2900 rpm

NEMA 213-5TC

460

60 Hz
3500 rpm

10

10

(2)

50 Hz
2900 rpm

130

NEMA 213-5TC

Weight

60 Hz
3500 rpm

20

556

(1)

NEMA 182-4TC

15

K10-MS

Noise level
Lp dB (A)

NEMA 182-4TC
NEMA 213-5TC

15

K09-MS

Maximum
differential pressure
p ( In WG )

7
K08-MS

Size

SCL Kxx-MS GOR-B

NEMA 213-5TC
NEMA 254-6TC

20
25

NEMA 254-6TC
NEMA 284-6TSC

30

NEMA 284-6TSC

150

40

NEMA 324-6TSC

180

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor
- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

86.9

151.00
147.30
170.00
170.00
176.40

177.70
184.10
184.10
177.70
177.70
193.20

REGENERATIVE BLOWERS - PRESSURE 29

SCL K07 / K08 / K09 / K10 / K11 / K12


MS SERIES - GOR/GVR RANGE

SN 2134-2S 2/2
Dp psig

25

220

30

7
20

180
10

15

6
20

25

20

180

40

160

50 Hz

In WG

60 Hz

In WG

Dp psig

220

25

20

160

25

15
15

30

140

15

5
20
25

10
15

100

10

40

20

K08-MS

K10-MS

200

300

400

500

600

700

6
5
4

K10-MS
K09-MS

120
K08-MS

100
3

80

60

K12-MS

K11-MS

140

K07-MS

40

In WG

Dp psig

160

140

10

15

20

25

K08-MS
K10-MS
K07-MS

K11-MS
K12-MS

80
60
40

20

20

40

60

80

100

120

140

160

K10-MS

K12-MS

0
100

200

300

400

500

600

180 F

700 Scfm

50 Hz

160

K09-MS

140

K08-MS

120

80

60

K11-MS

K10-MS

K12-MS

K07-MS

100

40
20
0
0

7
6
5
4

10

15

3
2

K09-MS

160

K10-MS

140
120

K08-MS

K11-MS
K07-MS

80
60
K12-MS

40
1

25 Hp

20

50 Hz

100

0
0

K11-MS

220

K09-MS

100

K09-MS
K08-MS

30 Hp

60 Hz

120

220

K07-MS

20

TEMPERATURE INCREASE

10

7 1/2

220

60 Hz

160

800 Scfm

In WG

Dp psig

220
7

7 1/2

60

20

K12-MS
0

100

10

K11-MS

0
0

15

80

40

10
7 1/2

K09-MS

K07-MS

15

15

10

7 1/2

7 1/2

60
7 1/2

100

Dp psig

15

10

10

120

20

80

ABSORBED POWER

20
15

In WG

7 1/2

In WG

120

140

20

CAPACITY

7 1/2

Dp psig

20
0
0

20

40

60

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120

140

160

180 F

30

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K05 / K06


TS SERIES - GOR/GVR RANGE
SN 2686-0 1/2

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any plane
G1/8'' female thread on both suction
and discharge silencer port flanges.

GVR Range

GOR Range
G 1/8

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

G 1/8

SCL Kxx-TS GOR-C

SCL Kxx-TS GOR-A

SCL Kxx-TS GOR-B

SCL Kxx-TS GOR-C

For dimensions, please refer to drw:


- GOR range: SI 2123
- GVR range: SI 2135

Model

Maximum
flow
m/h
60 Hz
3500 rpm

Installed
power
Hp

Size

50 Hz
2900 rpm

K05-TS

290

241

K06-TS

400

331

5.0
7.5

NEMA 182-4TC

7.5
10
15

NEMA 213-5TC

Maximum
differential pressure
p ( in WG )

Noise level
Lp dB (A)

Weight
(2)

(1)

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60

85

75.5

73.5

100

110

77.5

75.5

55

77

77.5

75.5

80
130

110

77.8

75.8

120

78.4

76.4

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Lbs
GOR

GVR

72.75

68.35

112.45

108.00

REGENERATIVE BLOWERS - PRESSURE 31

SCL K05 / K06


TS SERIES - GOR/GVR RANGE
SN 2686-0 2/2

p psig

p psig

60 Hz
15

120
4

50 Hz

120

15

4
7 1/2

10

80

60

7 1/2

10

100

CAPACITY

100

140
In WG

140
In WG

80

7 1/2

60

7 1/2

40

40

K06-TS

K06-TS

K05-TS

K05-TS

1
20

0
300

400

140

80
K06-TS

60
K05-TS
40

0
2

10 11

12 13

140

K05-TS
3

80
60
40

1
20
0

p psig

TEMPERATURE INCREASE

100

20

40

60

80

100

120 F

300

350

400 Scfm

80
K06-TS

60
K05-TS

20
0
1

140

10 Hp

50 Hz

120
4

K06-TS

100
3

K05-TS

80
60
40

1
20
0

250

50 Hz

60 Hz

K06-TS

200

140

14 15 Hp

In WG

p psig

150

40
1

0
0

100

100

20
0

50

60 Hz

100
3

500 Scfm

p psig

200

In WG

p psig

100

In WG

ABSORBED POWER

20

0
0

20

40

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

60

80

100

120

140 F

32

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 /K12


TS SERIES - GOR/GVR RANGE
SN 2164-3 1/2

TECHNICAL
CHARACTERISTICS
-

GVR RANGE

GOR RANGE

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
G1/8 female thread on both
suction and discharge silencer
port flanges

G 1/8

OPTIONS

G 1/8

- Special voltages (IEC 38)


- Surface treatments

ACCESSORIES
-

SCL Kxx-TS GOR-C

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

For dimensions, please refer to drw:


GOR range: SI 1879
GVR range: SI 1880

Model

SCL Kxx-TS GOR-A

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

588

487

10

K09-TS

715

941

592

780

K11-TS

K12-TS

1093

906

1254

1039

1410

1168

Noise level
Lp dB (A)

p ( In WG )

(1)

Weight
(2)

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Lbs

36

60

83.9

81.9

160.90

NEMA 213-5TC

36

60

83.9

81.9

160.90

NEMA 213-5TC

60

90

84.2

82.2

160.90

NEMA 213-5TC

110

140

84.8

82.8

160.90

110

140

84.8

82.8

167.60

20

NEMA 254-6TC (3)

140

140

85.3

82.8

167.60

10

NEMA 213-5TC

37

64

80.9

78.9

172.00

20

NEMA 213-5TC
NEMA 254-6TC (3)
NEMA 254-6TC (3)

75
75
100

105
105
150

83.3
83.3
84.6

81.3
81.3
82.6

172.00
180.80
180.80

25

NEMA 284-6TSC (3)

140

150

86.0

82.6

174.20

15

NEMA 213-5TC
NEMA 254-6TC (3)

52
52

75
75

83.0
83.0

81.0
81.0

202.80
208.30

20
25
30

NEMA 254-6TC (3)


NEMA 284-6TSC (3)
NEMA 284-6TSC (3)

80
110
120

108
145
160

85.0
87.0
89.0

83.0
85.0
87.0

208.30
205.00
205.00

40

NEMA 324-6TSC (3)

150

160

91.0

87.0

220.50

NEMA 213-5TC

41

64

87.8

85.8

209.40

NEMA 254-6TC (3)

41

64

87.8

85.8

216.10
216.10

15

15
K10-TS

NEMA 182-4TC

differential pressure

NEMA 254-6TC (3)

15

K08-TS

Maximum
Size

50 Hz
2900 rpm
7

K07-TS

SCL Kxx-TS GOR-B

20

NEMA 254-6TC (3)

65

90

88.1

86.1

25

NEMA 284-6TSC (3)

80

110

88.4

86.4

211.60

30

NEMA 284-6TSC (3)

100

140

88.7

86.7

211.60

40

NEMA 324-6TSC (3)

150

160

89.0

87.0

227.10

25
30

NEMA 284-6TSC
NEMA 284-6TSC

50
70

88
110

89.4
90.0

87.4
88.0

251.30
251.30

40
50

NEMA 324-6TSC (3)


NEMA 324-6TSC (3)

100
140

155
155

90.6
91.2

88.6
88.6

269.00
269.00

30

NEMA 284-6TSC

45

80

90.6

88.6

249.10

40
50

NEMA 324-6TSC (3)


NEMA 324-6TSC (3)

70
110

120
150

91.2
91.8

89.2
89.8

266.80
266.80

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor
(3) Not applicable on SCL Kxx - GVR
- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - PRESSURE 33

SCL K07 / K08 / K09 / K10 / K11 / K12


TS SERIES - GOR/GVR RANGE
SN 2164-3 2/2

160

50 Hz

In WG

p psig

180

60 Hz

In WG

p psig

180

160

30

40
40

40

20

40

50
25

20

25

50

120

30

15

140

30

15

120

25

100

40

30

80

20

40

50

20

CAPACITY

140

25

15
30

10

20

25

80

30
15

40
10

10

15

7 1/2

60

30

100

20

60

25

20

15

15

25
30
15

40

40

10

7 1/2

K08-TS

1
K08-TS

20

K10-TS

K12-TS

K10-TS

K07-TS
K09-TS

K07-TS
0

0
200

600

800

1000

1200

1400

120
4

K07-TS

K09-TS

K11-TS

100
K10-TS

K12-TS

60
40

1
0

20

30

40

140
K07-TS
K08-TS
100
K12-TS

K10-TS
80

K11-TS
60
K09-TS

40
1
0

20
0
20

40

60

80

100

120

140

160 F

In WG

1200 Scfm

K11-TS

K09-TS

K08-TS

80

K10-TS

K12-TS

60
40
20
0
0

140

10

20

40 Hp

30

50 Hz
K12-TS
K11-TS

120

K09-TS

K10-TS
100

80

60

K08-TS

K07-TS

40
1
20
0

1000

180

120

60 Hz

800

50 Hz

K07-TS

50 Hp

TEMPERATURE INCREASE

In WG

p psig

180

0
10

600

100

140

400

120

20

In WG

K08-TS

80

p psig

p psig

140

200

180

60 Hz

ABSORBED POWER

In WG

p psig

1400 Scfm

180
6

K11-TS

K09-TS

K11-TS
0

400

K12-TS

20

0
0

20

40

Curves refer to air at 68F temperature and 29.92 I n Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

60

80

100

120

140

160 F

34

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07R / K08R / K09 / K10 / K11 / K12


MD SERIES - GOR/GVR RANGE
SN 2149-1 1/2

GVR Range

GOR Range

TECHNICAL
CHARACTERISTICS
Aluminium alloy construction
Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

SCL Kxx-MD GOR-C

For dimensions, please refer to drw:


GOR range: SI 1918
GVR range: SI 1919

Model

SCL Kxx-MD GOR-A

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

129

107

5
168

139

7
10
15
5

K09-MD

221

183

7
10
15
7

K10-MD

275

228

10
15
10

K11-MD

306

254

15
20
15

K12-MD

336

278

differential pressure

p ( In WG )
60 Hz
3500 rpm

K08R-MD

Maximum
Size

50 Hz
2900 rpm
3

K07R-MD

SCL Kxx-MD GOR-B

20
25

NEMA 56C
NEMA 143-5TC
NEMA 182-4TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 182-4TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 182-4TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 254-6TC
NEMA 254-6TC
NEMA 213-5TC
NEMA 254-6TC
NEMA 254-6TC
NEMA 284-6TSC

50 Hz
2900 rpm

Noise level
Lp dB (A)
(1)

60 Hz
3500 rpm

50 Hz
2900 rpm

68

87

73.5

71.5

145

170

74.5

72.5

250

260

75.0

73.0

80

110

76.2

74.2

160

185

76.6

74.6

220
260

250
-

77.0
77.4

75.0
-

50

78

76.9

74.9

120

143

78.0

76.0

190
280

210
280

79.5
80.5

77.5
78.5

85

110

79.9

77.9

140
245

165
280

80.3
81.4

78.3
79.4

100

125

81.1

79.1

190

220

81.4

79.4

270

280

81.7

79.7

100

180

82.3

80.3

180
250

260
-

82.6
82.9

80.6
-

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor
- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Weight
(2)

Lbs
112.00
112.00
113.80
113.80
113.80
130.30
130.30
130.30
130.30
130.30
138.50
138.50
138.50
138.50
138.50
125.40
152.40
152.40
152.40
175.70
175.70
182.10
182.10
183.40
189.80
189.80
183.40

REGENERATIVE BLOWERS - PRESSURE 35

SCL K07R / K08R / K09 / K10 / K11 / K12


MD SERIES - GOR/GVR RANGE
SN 2149-1 2/2

280

15
20

10

280

15

260
7 1/2

220

25

15

240
8

11

In WG

10

320

60 Hz

p psig

In WG

p psig

320
11

50 Hz

15

20

10

7 1/2

260

15

20

240
8

10

220

15
10

200

10

15

180

CAPACITY

20

6
160

10

120

80

7
6
5
4
3
2
1
0

9
8
7
6
5
4
3
2
1
0

K10-MD

200

300

60 Hz

K11-MD
K10-MD

K12-MD

K09-MD
K08R-MD
K07R-MD

11

10
9
8
7
6
5
4
3
2

0
4

10

12

14

16

18

20

320

22

K08R-MD
K07R-MD
K12-MD

K09-MD
K10-MD

11

10
9
8
7
6
5
4
3
2
1

20

40

60

80

100

120

140

160

180 F

K10-MD

100

200

300 Scfm

320

50 Hz
K11-MD

240
220
200
180
160
140
120
100
80
60
40
20
0

K10-MD
K12-MD

K09-MD
K08R-MD
K07R-MD

0
0

K11-MD

K09-MD

K08R-MD

24 Hp

60 Hz

K11-MD

240
220
200
180
160
140
120
100
80
60
40
20
0

K07R-MD

1
2

K12-MD

400 Scfm

320

240
220
200
180
160
140
120
100
80
60
40
20
0

60

20
0

100

In WG

p psig

10

11

80

40

K11-MD

In WG

p psig

K09-MD

K08R-MD

7 1/2

In WG

K07R-MD

K12-MD

20

10

10

120

10

12

14

16

320

18 Hp

50 Hz

In WG

60
40

11

7 1/2

140

10

100
3

7 1/2

p psig

15

10

15

160

100
3

7 1/2

180

7 1/2

ABSORBED POWER

140

TEMPERATURE INCREASE

7 1/2
5

200

p psig

K11-MD
K07R-MD

240
220
200
180
160
140
120
100
80
60
40
20
0

K12-MD

K09-MD

K10-MD
K08R-MD

20

40

60

Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120

140

160

180 F

36

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 / K12


TD SERIES - GOR RANGE
SN 2179-2 1/2

TECHNICAL
CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
G1/8 female thread on both
suction and discharge silencer
port flanges

G 1/8

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

For dimensions, please refer to drw: S I 1971

Model

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm
7

K07-TD

296

245

10
15

K08-TD

368

305

387

K11-TD

K12-TD

571

642

716

473

532

593

NEMA 213-5TC
NEMA 213-5TC
NEMA 254-6TC

10

NEMA
NEMA
NEMA
NEMA

213-5TC
213-5TC
254-6TC
254-6TC

NEMA
NEMA
NEMA
NEMA
NEMA

213-5TC
254-6TC
254-6TC
284-6TSC
284-6TSC

15

20
25
30
15

K10-TD

NEMA 213-5TC

NEMA 254-6TC

15
467

NEMA 182-4TC

20

20

K09-TD

Maximum
Size

NEMA 213-5TC
NEMA 254-6TC

differential pressure

Noise level
Lp dB (A)

p ( In WG )

(1)

(2)

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Lbs

90

130

80.9

78.9

156.50

135

185

81.2

79.2

225

230

240

81.8

79.8

82.1
80.4

78.4

170

220

81.5

79.5

220

240

82.3

80.3

105

155

82.7

80.7

160
220
240

225

83.0
83.3
83.6

81.0
81.3
81.6

85

130

86.6

84.6

180

86.9

84.9

NEMA 254-6TC

130

25

NEMA 284-6TSC

180

30

NEMA 284-6TSC

200

40

NEMA 324-6TSC

240

20

NEMA 254-6TC

87.2
240

87.5

160.90
160.90

140

240

156.50
156.50

95

20

169.80
169.00
178.60
178.60
196.20
201.70
201.70
198.40
198.40
202.80
209.50
209.50
205.00

85.2

205.00

87.8

220.50

90

140

87.4

85.4

246.80

180

87.9

85.9

244.70

25

NEMA 284-6TSC

130

30

NEMA 284-6TSC

150

40

NEMA 324-6TSC

240

25
30
40
50

NEMA
NEMA
NEMA
NEMA

85
120
190
240

284-6TSC
284-6TSC
324-6TSC
324-6TSC

Weight

240
140
190
240
-

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor
- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

88.4
88.9
88.2
88.7
89,2
89.5

86.4
86.2
86.7
87.2
-

244.70
264.50
242.5
242.5
262.3
262.3

REGENERATIVE BLOWERS - PRESSURE

SCL K07 / K08 / K09 / K10 / K11 / K12


TD SERIES - GOR RANGE
SN 2179-2 2/2
p psig

In WG

p psig

10

10

60 Hz

280

50 Hz

In WG

300

9
260

240
15
20

240
8

220

40

30

15

20

50

40

200

25
20

140

10

25

20

30

160
5

20

15

25

80

K08-TD
20

400

500

600

700

240
220
200
180
160

140

120
100

3
2

K07-TD

K09-TD

K08-TD

K11-TD

K10-TD

K12-TD

80
60

220

200

6
5
4

60

30

In WG

K09-TD
K10-TD

140
120

60
40

K08-TD

160

700

Scfm

50 Hz

K07-TD

K09-TD

K08-TD

60 Hz

220
200
180

100
80

600

K11-TD
K12-TD

K10-TD

K11-TD
K07-TD
K12-TD

20
0

10

220

20

40

60

80

100

120

140

160

180 F

10

30

140

Hp

K08-TD

180
160

40

50 Hz

200

20

280

K09-TD
K10-TD

K11-TD

120
K07-TD

100
3

80

60

K12-TD

40
1
0

Hp

240

50

40

TEMPERATURE INCREASE

500

20

In WG

20

p psig

10

300

400

40
0

300

120

200

140
100
80

100

160

K09-TD

180

10

K12-TD
K11-TD

280

40
20
0

p psig

10

ABSORBED POWER

800 Scfm

60 Hz

K07-TD

K10-TD

In WG

300

p psig

200

K08-TD
20

In WG

p psig

60

K11-TD

K09-TD

K07-TD

0
100

K12-TD

K10-TD

300

80

40

40
1

25

120

60

10

20
15

10

100

10

7 1/2

25

15

140
7 1/2

15

100

20

CAPACITY

15

160

30

10

120

200
180

40

30

40

20

15

30

180
6

220

30

25

25

7
7

25

20

20
0
0

20

40

60

Curves refer to air at 68F temperature and 29.92 I n Hg atmospheric pressure (abs) measured at inlet port.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120

140

160

180 F

37

38

FPZ, Inc

REGENERATIVE BLOWERS - PRESSURE

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K09 / K10 / K11


TT SERIES - GOR RANGE
SN 2778-1 1/2

TECHNICAL
CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
G1/8 female thread on both
suction and discharge silencer
port flanges

G 1/8

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
- Inlet and/or inline filters
- Additional inlet/outlet silencers
- Optional connectors

Model

Maximum
flow

Installed
power

Scfm

Hp

60 Hz
3500 rpm
K09-TT

423

Maximum
Size

50 Hz
2900 rpm
351

25
30
40
30
40
50

K10-TT

526

436

K11-TT

597

495

40
50

NEMA 284-6TSC
NEMA 324-6TSC
NEMA 284-6TSC
NEMA 324-6TSC
NEMA 324-6TSC

differential pressure

p ( In WG )

Noise level
Lp dB (A)
(1)

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

220
330

260
330
-

88.2
88.5

85.9
86.2
-

260
340

260
340
-

88.8
89.1

86.5
86.8
-

220

300

89.1

87.1

320

350

89.5

87.5

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Weight
(2)

Lbs
354
363
365
380
434

REGENERATIVE BLOWERS - PRESSURE 39

SCL K09 / K10 / K11


TT SERIES - GOR RANGE
SN 2778-1 2/2

12

50

40

320

50

280

10

160

8
7
6

K11-TT
80

K10-TT
K09-TT

5
4
3
2
1
0

11
10
9
8

K11-TT

200
K10-TT

160
K09-TT

120
80

1
0

13
12
10
9
8
7
6
5
4
3
2
1

0
5

10

15

20

25

30

35

40

400

45

320
K10-TT

240
K11-TT

K09-TT

120
80
40
0
0

20

40

60

80

100

120

140

160

180

200

220 F

300

13
12
11
10
9
8

320
280
240
K11-TT

200
K10-TT

160
K09-TT

120
80
40
0

1
0

20

25

30

40 Hp

35

50 Hz
K11-TT
K10-TT

240

160

15

280

10

320

200

400

7
5

600 Scfm

500

50 Hz

14

400

400

50 Hp

60 Hz

280

0
200

In WG

14

11

40

160

p psig

60 Hz

240

700 Scfm

280

200

600

320

7
5

500

In WG

p psig

13
12

400

400

14

300

In WG

0
200

ABSORBED POWER

K10-TT
K09-TT

40

p psig

80

TEMPERATURE INCREASE

10
9

120

In WG

p psig

11

160

K11-TT
3

40

13
12

200

5
120

14

30

240

CAPACITY

40

30
200

25

40
280

40

30

320

240

50
40

11

13
12

11
10

50 Hz

14
In WG

p psig

13

400

60 Hz

In WG

p psig

400
14

K09-TT

120
80
40
0
0

20

40

60

80

100

120

- Curves refer to air at 68F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port.
- Values for flow, power consumption and temperature rise: +/-10% tolerance.
- Data subject to change without notice.

140

160

180

200

220 F

40

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K03 / K04 / K05 / K06


MS SERIES
SN 1879-8 1/2
H

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor

p1

OPTIONS

3x120
u

- Special voltages (IEC 38)


- Surface treatments

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

d
Accessory
o

Dimensions in inches.
Dimension for reference only.

Model

K03-MS
K04-MS
K05-MS
K06-MS

9.49
11.22
12.87
14.80

10.55
12.40
14.37
15.47

5.79
6.77
7.87
8.07

Model

1.69 9.06 8.07 1 NPT


1.93 10.04 8.86 11/2 NPT
2.13 12.60 10.24 2 NPT
2.13 12.80 11.42 2 NPT

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm

G
I
f
e

3.39
4.02
4.72
4.92

0.39
0.47
0.59
0.59

p1

3.27 5.59 8.07


3.74 6.73 8.74
4.53 10.43 12.60
5.51 10.71 13.15

Maximum
differential pressure

p ( In Hg )

0.71
0.71
0.71
0.71

2.95
2.76
3.86
3.35

0.16
0.16
0.16
0.16

M6
M6
M8
M8

5.51
6.89
7.87
9.45

0.47
0.71
0.75
0.75

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

3/4
1

4.7
5.9

3.7
4.9

61.0
61.3

59.0
59.3

10.43
11.97

24.30
26.50

K03-MS

52

43

3/4
1

K04-MS

98

81

1
2
3

1
2
-

4.3
6.3
7.4

5.9
6.6
-

63.8
64.0
64.2

61.8
62.0
-

11.65
13.78
13.78

36.40
43.00
49.60

K05-MS

156

129

2
3
4

2
3
-

3.8
6.6
8.1

5.1
7.1
-

69.5
69.8
70.1

67.5
67.8
-

13.20
13.20
14.40

51.80
58.40
67.20

3.7

4.8

72.0

70.0

13.54

68.70

5.5

7.0

72.3

70.3

14.17

71.65

8.1

8.1

72.6

70.6

6 1/5 (2)

9.6

72.9

14.17
14.45

77.60
77.60

K06-MS

216

179

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) No cURus motor

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - VACUUM 41

SCL K03 / K04 / K05 / K06


MS SERIES
SN 1879-8 2/2

p In Hg

In WG

p In Hg

120

60 Hz
6 1/5

120

50 Hz

In WG

140
10

5 1/2

100
4

5 1/2

100

6
3

1
4

5
3/4

60

1 1/2

3/4

2
20
K03-MS

K05-MS

0
50

100

150

200

K04-MS

K03-MS
40

8
7
6
5

140

80

150

200 cfm

K06-MS
K05-MS

K04-MS
K03-MS

40

2
20

K06-MS
K04-MS

K05-MS
80
K03-MS

60

40
20
0

8
7
6

20

40

60

80

100

120

140

160

180

200 F

Hp

50 Hz
K06-MS
K05-MS

80

K04-MS

5
60

K03-MS

4
3

40

2
20
1
0

120

60 Hz

100

Hp

1
0

0
1

4
3

60

In WG

p In Hg

100

10

K06-MS

50 Hz

20

TEMPERATURE INCRESASE

50

p In Hg

60

In WG

K05-MS

p In Hg

K06-MS

80

K05-MS

120

ABSORBED POWER

60 Hz

100

K04-MS

250 cfm

140

K03-MS

K06-MS

In WG

p In Hg

K04-MS

0
0

40

40

20

10

60

In WG

1 1/2

80

CAPACITY

80

0
0

20

40

60

80

100

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

120

140

160

180

200 F

42

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 K08 / K09 / K10 / K11 / K12


MS SERIES
SN 1810-15 1/2
H

TECHNICAL CHARACTERISTICS
-

p1

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor

3x120
u

OPTIONS

- Special voltages (IEC 38)


- Surface treatments

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

Accessory

s
I

Dimensions in inches.
Dimension for reference only.

Model

p1

K07-MS
K08-MS
K09-MS
K10-MS
K11-MS
K12-MS

16.69
17.99
19.37
20.31
21.34
21.57

18.84
19.61
22.09
22.56
23.74
23.82

10.59
10.59
12.40
12.40
13.07
13.07

3.23
3.23
3.78
3.78
3.58
3.58

18.43
18.82
20.00
20.00
21.26
21.26

17.24
17.64
18.82
18.82
20.00
20.00

3 NPT
3 NPT
4 NPT
4 NPT
4 NPT
4 NPT

6.10
6.10
7.17
7.17
7.87
7.87

0.51
0.51
0.51
0.51
0.51
0.51

11.81
11.81
11.81
11.81
11.81
11.81

13.78
13.78
13.78
13.78
13.78
13.78

20.16
20.16
23.07
23.07
23.46
23.58

0.98
0.98
0.98
0.98
0.98
0.98

5.39
5.39
7.83
7.83
8.03
8.03

0.20
0.20
0.20
0.20
0.20
0.20

M8
M8
M8
M8
M8
M8

11.61
12.2
14.17
14.17
15.35
15.35

0.63
0.63
0.63
0.63
0.63
0.51

Model

Maximum
flow

Installed
power

differential pressure

Noise level
Lp dB (A)

Overall
dimensions

cfm

Hp

Dp ( In Hg )

(1)

60 Hz
3500 rpm

K07-MS

K08-MS

K09-MS

294

381

471

Maximum

Weight

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

243

4
5
7
10

4
5
7
-

3.7
5.6
9.6
11.1

4.6
6.3
8.9
-

77.7
78.0
78.3
78.6

75.7
76.0
76.3
-

15.45
15.45
18.37
18.37

103.00
107.10
145.70
154.50

316

5
7
10
15

5
7
10
-

2.9
5.0
8.5
11.1

3.8
6.6
9.2
-

78.8
79.1
79.4
79.7

76.8
77.1
77.4
-

15.45
18.37
18.37
19.15

115.70
154.30
163.10
184.00

390

7
10
15
20

7
10
15
-

3.7
5.9
10.3
11.1

4.6
7.0
10.4
-

79.3
79.6
80.1
80.4

77.3
77.6
78.1
-

18.84
18.84
19.63
23.74

166.50
175.10
196.20
269.00

7
10
15
-

2.7
4.7
8.8
11.1

3.8
5.9
9.9
-

79.4
79.7
80.2
80.5

77.4
77.7
78.2
-

18.84
18.84
19.63
23.74

170.90
179.50
200.60
273.40

K10-MS

556

460

7
10
15
20

K11-MS

650

539

10
15
20

10
15
20

2.9
6.0
11.1

3.9
7.1
10.4

82.0
82.5
83.0

80.0
80.5
81.0

19.04
19.83
23.94

194.90
216.00
288.80

K12-MS

726

602

15
20
25

15
20
-

3.8
6.3
10.3

6.6
9.6
-

83.5
84.3
87.2

81.5
82.3
-

19.95
24.06
24.92

223.70
296.50
320.80

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - VACUUM

SCL K07 / K08 / K09 / K10 / K11 / K12


MS SERIES
SN 1810-15 2/2

140

20

20

20

25

15

10

11

50 Hz

In WG

15

10

p In Hg

11

160

60
50 Hz
Hz

In WG

p In Hg

160

15

140

20
15

10
7 1/2

20

15

120

10

7 1/2

120

10

8
100

100

20

15

10

80
5 1/2
7 1/2

10

7 1/2

15

5 1/2

10

80

5
4

60

7 1/2

60

4
4

15

10

CAPACITY

15

7 1/2
5 1/2

40

10

5 1/2

7 1/2

10

40

7 1/2

K08-MS

K10-MS

K12-MS

20
K07-MS

K11-MS

K07-MS
0

300

400

500

600

700

120

K08-MS

8
7
6

K10-MS

K09-MS

K07-MS

K11-MS

K12-MS

100
80

5
4
3
2

60
40

4
3

0
10

15

120

60 Hz

K11-MS
K10-MS

K07-MS

K09-MS
K08-MS

8
7
6

100
80

5
4
3
2

60
K12-MS
40
20

1
0

20

40

60

80

100

120

140

160

180

200 F

400

500

700 cfm

600

50 Hz

K08-MS

K10-MS

K12-MS

K07-MS

K11-MS

K09-MS

80
60
40
20
0
0

10

10
9

120

50 Hz
K11-MS
K10-MS
K08-MS

8
7
6

K09-MS

100
80

5
4
3
2

20 Hp

15

160
11

K07-MS

60
40
K12-MS
20

1
0

300

100

25 Hp

20

p In Hg

200

TEMPERATURE INCRESASE

In WG

p In Hg

120

10

20

160
11

10

100

1
0

K11-MS

K09-MS

160
11

In WG

60 Hz

ABSORBED POWER

10

K12-MS

800 cfm

In WG

200

p In Hg

100

160
In WG

p In Hg

K09-MS

0
0

11

K10-MS

K08-MS
20

0
0

20

40

60

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120

140

160 F

43

44

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K05 / K06


TS SERIES
SN 1926-5 1/2
a

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor 3x120u

H
z

p1

t
b

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

c
d

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

Accessory

n
o

G
I
f
e

Dimensions in inches.
Dimension for reference only.

Model

p1

K05-TS

12.87 16.61 10.16 3.03 15.91 14.72

3 NPT

5.91

0.51 11.81 13.58 24.96 0.98 12.91 0.16

M8

7.87

0.75

K06-TS

14.80 17.72 10.31 2.95 15.91 14.72

3 NPT

6.10

0.51 11.81 13.58 26.06 0.98 13.19 0.16

M8

9.45

0.75

Model

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K05-TS

290

241

K06-TS

400

331

60 Hz
3500 rpm
3
4
5
5
7
10

50 Hz
2900 rpm
3
4
5
5
7
10

Maximum
differential pressure
p ( In Hg )
60 Hz
50 Hz
3500 rpm 2900 rpm
3.3
2.2
5.1
3.4
6.6
5.3
4.0
2.7
4.8
4.0
6.8
6.3

Noise level
Lp dB (A)

Overall
dimensions

(1)

60 Hz
3500 rpm
71.6
73.1
75.1
76.8
77.1
77.4

50 Hz
2900 rpm
69.6
71.1
73.1
74.8
75.1
75.4

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Inches
17.45
18.64
18.64
18.98
22.60
22.60

Weight

Lbs
85.98
89.29
93.70
104.72
141.09
149.91

REGENERATIVE BLOWERS - VACUUM

SCL K05 / K06


TS SERIES
SN 1926-5 2/2
120

10

50 Hz

In WG

60 Hz

p In Hg

In WG

p In Hg

100

100

80

10
5

1/2

CAPACITY

5
60
7

1/2

80

1/2

60

1/2

40

1/2

3
5

1/2

40

K06-TS

K05-TS

K06-TS
2

K05-TS

20

20
1
1

0
200

300

400

100

80

60
4
K06-TS
40
K05-TS
2
20

300

350

400 cfm

50 Hz

80
K06-TS

60
K05-TS

4
3

40

2
20

10

Hp

60 Hz

80

60
4
K05-TS
40

2
20
1

120
p In Hg

TEMPERATURE INCREASE

In WG

p In Hg

K06-TS

250

0
1

200

100

150

1
0

100

120

60 Hz

50

10 Hp

50 Hz

In WG

ABSORBED POWER

500 cfm

In WG

100

In WG

p In Hg

p In Hg

7
6

K06-TS

K05-TS

80

5
60
4
3

40

2
20
1

0
0

20

40

60

80

100 F

0
0

20

40

60

80

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

100

120

140

160 F

45

46

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 / K12


TS SERIES
SN 1826-11ss
For model K09-K10K11-K12 -TS only
j
Int.k

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor
G1/8 female thread on both suction
and discharge silencer port flanges

For model K11-K12-TS Hp 30 60Hz only

H
z

3x120u

OPTIONS

a
p1

G 1/8

- Special voltages (IEC 38)


- Surface treatments

b
c

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

d
Accessory

m
n

s G

I
f
e

Dimensions in inches.
Dimension for reference only.

Model

K07-TS
K08-TS
K09-TS
K10-TS
K11-TS
K12-TS

16.69
18.03
19.37
20.31
21.26
21.57

20.91
21.57
24.02
24.53
25.59
25.66

12.56
12.56
14.37
14.37
14.96
14.96

3.86
3.86
4.41
4.41
4.17
4.17

18.43
18.82
20.00
20.00
21.26
21.26

Model

17.24 4NPT 7.17


17.64 4NPT 7.17
18.82 5.12 8.27
18.82 5.12 8.27
20.08 5.12 8.98
20.08 5.12 8.98

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K07-TS

588

487

K08-TS

715

592

K09-TS

941

780

K10-TS

1093

906

K11-TS

1254

1039

K12-TS

1410

1168

M16
M16
M16
M16

8.27
8.27
8.27
8.27

0.51
0.51
0.51
0.51
0.51
0.51

9.84
9.84
9.84
9.84
9.84
9.84

21.65
21.65
21.65
21.65
21.65
21.65

Maximum
differential pressure

p ( In Hg )

p1

31.57 0.98 11.77 0.20


31.57 0.98 11.77 0.20
33.46
12.40 0.20
33.46
12.40 0.20
34.25
12.60 0.20
34.37
12.60 0.20

M8
M8
M8
M8
M8
M8

11.61
12.20
14.17
14.17
15.35
15.35

0.63
0.63
0.63
0.63
0.63
0.63

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

60 Hz
3500 rpm
7
10
15
7
10
15
20
25

50 Hz
2900 rpm
7
10
15
7
10
15
20
25

60 Hz
3500 rpm
2.6
4.4
8.1
1.3
2.7
5.5
5.9
8.1

50 Hz
2900 rpm
3.5
5.2
8.9
2.2
3.7
6.4
6.6
8.8

60 Hz
3500 rpm
84.5
84.8
85.4
80.9
81.2
82.9
84.1
86.1

50 Hz
2900 rpm
82.5
82.8
83.4
78.9
79.2
80.9
82.1
84.1

Inches
23.76
23.76
24.55
23.76
23.76
24.55
29.92
30.79

Lbs
197.31
206.13
223.77
205.47
214.29
231.92
350.53
383.60

20
25
25
(2)
30
(2)
30

20
25
25
(2)
30
(2)
30

4.8
5.9
3.7
5.1
3.3

5.5
7.0
5.0
6.6
5.9

89.4
89.7
90.7
91.3
91.9

87.4
87.7
88.7
89.3
89.9

29.92
30.79
31.38
31.38
31.50

354.94
388.01
429.02
434.53
436.75

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) K11-K12-TS Hp 30 vertical assembly only.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - VACUUM 47

SCL K07 / K08 / K09 / K10 / K11 / K12


TS SERIES
SN 1826-11ss

120
15

25

10

50 Hz

In WG

p In Hg

140

60 Hz

In WG

p In Hg

140
10

15

120

25

100

100

25
20

30

15

80

25

20
15

30

20

60

CAPACITY

10

80

30
20
10

25

60

4
25

40

10

7 1/2

10

7 1/2

30

K10-TS

7 1/2

2
20

K10-TS

7 1/2

K12-TS
K11-TS

40

K07-TS

K09-TS

K09-TS
20

K12-TS

K08-TS

K11-TS

K07-TS

K08-TS
0

0
1000

1400

140

60 Hz

100
80
K10-TS

3
2
1
0

60
K08-TS

40

6
5

400

600

4
3
2

800

1000

140

1200

cfm

50 Hz

100
80

K10-TS

0
2

10 12 14 16 18 20

22 24

26 28 30

K11-TS

K09-TS

60

K12-TS

K08-TS
K07-TS

40
20

140

60 Hz

100

K07-TS
K10-TS

80

K09-TS

K08-TS
60
K11-TS

40

K12-TS
20
0

10
9

20

40

60

80

100

120

7
6
5

10

12

14

16

18

20

140

22

24

26

50 Hz
K09-TS

K10-TS

100

K11-TS

K07-TS

80
K12-TS

K08-TS

60

4
3
2

40
20

1
0

Hp

1
0

4
3

200

8
7

10

20

In WG

K12-TS

K07-TS

10

K11-TS

K09-TS

In WG

TEMPERATURE INCRESASE

1600 cfm

8
7

p In Hg

1200

In WG

800

p In Hg

600

ABSORBED POWER

10

400

In WG

p In Hg

200

p In Hg

0
0

20

40

60

80

100

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

120

140

160

180

200 F

Hp

48

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07R / K08R / K09 / K10 / K11 / K12


MD SERIES
SN 1852-8 1/2

TECHNICAL CHARACTERISTICS
-

p1

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor

t
3x120
u

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

b
c

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

d
G

m
n
o

I
f
e

Dimensions in inches.
Dimension for reference only.

Model

p1

K07R-MD
K08R-MD
K09-MD
K10-MD
K11-MD
K12-MD

16.69
17.99
19.37
20.31
21.35
21.57

18.94
19.61
22.09
22.56
23.74
23.85

10.59
10.59
12.40
12.40
13.07
13.07

3.23
3.23
3.78
3.78
3.58
3.58

18.43
18.82
20.00
20.00
21.18
21.18

17.24
17.64
18.82
18.82
20.00
20.00

2 NPT
2 NPT
4 NPT
4 NPT
4 NPT
4 NPT

6.10
6.10
7.17
7.17
7.87
7.87

0.51
0.51
0.51
0.51
0.51
0.51

11.81
11.81
11.81
11.81
11.81
11.81

13.78
13.78
13.78
13.78
13.78
13.78

16.46
16.46
25.35
25.35
25.75
25.87

0.71
0.71
0.98
0.98
0.98
0.98

1.7
1.7
10.12
10.12
10.31
10.31

0.20
0.20
0.20
0.20
0.20
0.20

M8
M8
M8
M8
M8
M8

11.61
12.20
14.17
14.17
15.35
15.35

0.63
0.63
0.63
0.63
0.63
0.52

Model

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm

K07R-MD

K08R-MD

K09-MD

K10-MD

K11-MD

K12-MD

129

168

221

275

306

336

50 Hz
2900 rpm

107

139

183

228

254

278

Maximum
differential pressure

Dp ( In Hg )

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

5.0

6.4

72.5

70.5

16.14

101.40

8.1

9.4

73.0

71.0

16.14

103.60

11.0

12.5

73.5

71.5

16.14

111.50

13.2

74.0

17.52

134.50

6.3

8.1

75.7

73.7

16.14

116.90

11.9

13.2

76.1

74.1

17.52

140.00

10

13.2

76.4

17.52

151.00

4.0

5.7

76.4

74.4

16.54

144.40

8.8

10.5

77.5

75.5

17.95

167.60

10

10

14.0

14.0

79.0

77.0

17.95

178.60

6.3

8.1

80.4

78.4

17.91

170.90

10

10

10.3

12.1

80.7

78.7

17.91

181.90

15

15

14.7

14.7

81.3

79.3

19.29

203.90

10

10

7.4

9.2

80.7

78.7

18.11

211.60

15

15

14.0

14.7

81.3

79.3

20

14.7

81.6

19.49
23.23

232.60
287.20

15

15

7.4

13.2

82.2

80.2

19.61

240.30

20

13.2

82.5

23.42

295.00

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - VACUUM 49

SCL K07R / K08R / K09 / K10 / K11 / K12


MD SERIES
SN 1852-8 2/2

15

200

15

180

7 1/2

16

15

50 Hz

In WG

17

15

20

10

14
13

p In Hg

16

240

60 Hz

In WG

p In Hg

240
17

15

200

10

20

13

15

10

14

7 1/2

180

15

5 1/2

5 1/2

11

10

120

7 1/2
4

8
7
6

100

10

4
3

40

K08R-MD

K10-MD

K12-MD

10
8
6
4

20

K07R-MD

K09-MD

K11-MD

0
200

300

400

180
160
140

K07R-MD

K12-MD

K10-MD

K08R-MD

K11-MD

K09-MD

120
100
80
60

16
14
12
10
8
6

0
4

10

12

14

16

18

10

6
4

K09-MD
K07R-MD

180
160

K10-MD

K11-MD

K12-MD

140
K08R-MD

100
80
60
40

2
0

100

200

300

cfm

50 Hz

180
160

K07R-MD

K12-MD

K10-MD

K08R-MD

140

K11-MD

K09-MD

120
100
80
60

20
0
20

40

60

80

100

120

140

160

180

200

0
0

10

12

240
16
14
12
10
8
6
4

14

Hp

200

50 Hz
K11-MD
K09-MD

180

K12-MD

160

K10-MD

140

K07R-MD

120

K08R-MD

100
80
60
40

2
0

20

Hp

60 Hz

120
8

20

p In Hg

In WG

p In Hg

12

K11-MD

40
2

20

240

14

K09-MD

0
0

16

K07R-MD

240

60 Hz

TEMPERATURE INCREASE

K12-MD

K10-MD

K08R-MD

20

cfm

p In Hg

100

40
2

40

In WG

p In Hg

12

5 1/2

5 1/2

240

14

80
60

60

16

7 1/2

ABSORBED POWER

5 1/2

100
3

2
1

10

120

15

7 1/2

140
4

7 1/2

5 1/2

80

11
10

In WG

140

10

160

In WG

10

12

7 1/2

160

CAPACITY

12

20
0
0

20

40

60

80

100

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

120

140

160

180

50

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K04 / K05 / K06


TD SERIES
SN 1936-5 1/2
y

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor

I1

45

H
p1

z
t

OPTIONS
b

- Special voltages (IEC 38)


- Surface treatments
-

d1

ACCESSORIES

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

x
p2

3x120 u

m
r

n
r1
o

G
I2

q
f
e

Dimensions in inches.
Dimension for reference only.

Model

d1

I1

I2

p1

p2

r1

K04-TD

11.22 12.40 6.77 1.93 4.76 10.04 8.86 1 NPT 4.84 2.01 0.47 3.74 6.73 12.44 10.00 0.71 2.76 0.59 0.16 M6

6.89 7.40 8.43 6.81 0.71

K05-TD

12.87 14.37 7.87 2.13 5.51 12.60 10.24 2 NPT 5.71 2.36 0.59 4.53 10.43 16.85 13.39 0.71 3.86 1.57 0.16 M8

7.87 11.26 11.54 8.11 0.75

K06-TD

14.80 16.54 9.13 2.32 6.69 12.80 11.42 2 NPT 5.94 2.87 0.59 5.51 10.43 19.92 13.94 0.71 5.35 0.75 0.16 M8

9.45 11.26 12.13 8.27 0.75

Model

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K04-TD

99

82

K05-TD

153

127

K06-TD

222

184

60 Hz
3500 rpm

50 Hz
2900 rpm

2
3
3
4
5
5
7
10

2
3
3
4
5
5
7
10

Maximum
differential pressure
p ( In Hg )
60 Hz
50 Hz
3500 rpm 2900 rpm
5.1
7.0
8.8
8.1
5.1
7.0
7.7
9.9
11.0
11.8
5.9
8.8
9.2
10.3
11.8
11.8

Noise level
Lp dB (A)

Overall
dimensions

(1)

60 Hz
3500 rpm

50 Hz
2900 rpm

70.6
71.6
72.6
74.1
75.6
74.6
75.6
76.6

68.6
69.6
70.6
72.1
73.6
72.6
73.6
74.4

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Inches
17.26
17.26
17.45
18.64
18.64
18.98
22.60
22.60

Weight

Lbs
62.83
69.44
84.88
88.18
92.59
103.62
139.99
148.81

REGENERATIVE BLOWERS - VACUUM

SCL K04 / K05 / K06


TD SERIES
SN 1936-5 2/2

10

160
5

11

13

p In Hg

12

1/2

CAPACITY

100

80

5
2

1/2

40

K04-TD

K05-TD

K06-TD

0
150

200

180

60 Hz

140
K06-TD
120
K05-TD

100
80

K04-TD

60
40

12
11

7
6
5
4
3

9
8
7
6
5

180

60 Hz
K06-TD

140

K05-TD

120
100

K04-TD

80
60

4
3
2

40
20

K05-TD
100
K04-TD
80
60
40
20
0
0

13
12

180

Hp

50 Hz

11
10
9
8
7
6
5

140
K06-TD
120
100

K04-TD
K05-TD

80
60

4
3
2

40
20

1
0

50 Hz

120

Hp

p In Hg

TEMPERATURE INCREASE

11
10

200 cfm

In WG

p In Hg

12

150

K06-TD

9
8

13

100

140

10

20

50

180

13

1
0

250 cfm

4
3

K06-TD

In WG

100

p In Hg

50

ABSORBED POWER

K05-TD

K04-TD

In WG

p In Hg

40

20

8
7

80

60

11

100

20

10

1/2

12

13

1/2

120

60

7
4

1/2

120

10

1/2

10

160

140

10

50 Hz

11

140

180

In WG

12

60 Hz

In WG

p In Hg

13

180

0
0

20

40

60

80

100

120

140

160

180 F

0
0

20

40

60

80

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

100

120

140

160

180 F

51

52

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 /K12


TD SERIES
SN 1834-10 1/2
y

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
Recognized TEFC - cURus motor
G1/8 female thread on both suction
and discharge silencer port flanges

G 1/8

45

I1

H
p1

z
3x120
u

w
t

OPTIONS

- Special voltages (IEC 38)


- Surface treatments

ACCESSORIES
-

d1

G 1/8

x
p2

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

m
r

G
I2

f
e

Dimensions in inches.
Dimension for reference only.

Model
K07-TD
K08-TD
K09-TD
K10-TD
K11-TD
K12-TD

Model

d1

I1

I2

p1

p2

16.69 18.94 10.59 3.23 7.56 18.43 17.24 3NPT 7.36 3.05 0.51 11.81 13.78 25.55 15.43 0.98 5.39 0.20

M8 11.61 18.94 12.56 10.24 0.63

17.99 19.61 10.59 3.23 7.56 18.82 17.64 3NPT 7.36 3.05 0.51 11.81 13.78 25.55 15.43 0.98 5.39 0.20

M8 12.20 18.94 12.56 10.24 0.63

19.37 22.09 12.4 3.78 8.86 20.00 18.82 4NPT 8.66 3.58 0.51 11.81 13.78 29.33 17.91 0.98 7.83 0.20

M8 14.17 21.89 14.65 11.89 0.63

20.31 22.56 12.4 3.78 8.86 20.00 18.82 4NPT 8.66 3.58 0.51 11.81 13.78 29.33 17.91 0.98 7.83 0.20

M8 14.17 21.89 14.65 11.89 0.63

21.26 23.70 13.07 3.54 9.13 21.18 20.00 4NPT 9.53 3.94 0.51 11.81 13.78 30.12 18.50 0.98 8.03 0.20

M8 15.35 21.89 15.24 12.76 0.63

21.57 23.81 13.07 3.54 9.13 21.18 20.00 4NPT 9.53 3.94 0.51 11.81 13.78 30.23 18.50 0.98 8.03 0.20

M8 15.35 21.89 15.24 12.76 0.63

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K07-TD

296

245

K08-TD

368

305

K09-TD

467

387

K10-TD

571

473

K11-TD

642

532

K12-TD

716

593

60 Hz
3500 rpm
7
10
15
7
10
15
15
20
25
15
20
25
20
25
25
30

50 Hz
2900 rpm
7
10
15
7
10
15
15
20
15
20
25
20
25
25
30

Maximum
differential pressure

p ( In Hg )

60 Hz
3500 rpm
6.6
9.9
13.2
4.3
7.0
12.5
7.7
11.7
14.0
6.3
9.6
13.2
6.6
9.6
6.3
8.8

50 Hz
2900 rpm
7.7
11.0
12.6
5.5
8.1
13.6
9.2
13.2
7.4
11.0
14.7
8.5
11.4
10.3
14.0

Noise level
Lp dB (A)

Overall
dimensions

(1)

60 Hz
3500 rpm
78.6
78.9
79.5
79.0
79.3
79.9
82.2
82.5
82.8
85.9
86.2
86.5
86.7
87.2
87.5
88.0

50 Hz
2900 rpm
76.6
76.9
77.5
77.0
77.3
77.9
80.2
80.5
83.9
84.2
84.5
84.7
85.2
85.5
86.0

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Inches
23.76
23.76
24.55
23.76
23.76
24.55
25.81
29.92
30.79
25.81
29.92
30.79
31.38
31.38
31.50
31.50

Weight

Lbs
194.00
202.82
220.46
202.16
210.98
228.62
222.66
347.22
380.29
271.17
351.63
384.70
392.64
425.71
423.50
429.00

REGENERATIVE BLOWERS - VACUUM

SCL K07 / K08 / K09 / K10 / K11 / K12


TD SERIES
SN 1834-10 2/2

25

14
13

240

25

13

20

160

12

30

15

180

20

160

120

CAPACITY

25
30

15

100

10

7
7

20

1/2

15

10
9

80

140

25
15

120

20
10

8
7

25

20

10

11

10

25

25

140

20

200

15

11
10

50 Hz

14

15

12

16
15

15

180

17

In WG

60 Hz

p In Hg

15

220
In WG

p In Hg

16

1/2

100

15

80

5
60

60

160

10

140

300

400

500

600

700

800

60 Hz

120
100

K09-TD

K08-TD

80

K11-TD

K10-TD

K12-TD

60
40

In WG

p In Hg

12

160

10

140

10

20

14

30

25

160

10

140

K10-TD
K07-TD

K08-TD

100

60

500

6
4

700

600

K07-TD

100

K09-TD

cfm

K11-TD
K12-TD

K08-TD K10-TD

80
60

K11-TD
K09-TD

K12-TD

40
20
0
20

40

60

80

100

120

140

160

0
0

16
14

10

15

20

25

160

10

140

180 F

50 Hz
K07-TD
K10-TD
K08-TD

120
8
6
4

K09-TD

100
80

K11-TD

60
K12-TD

40
2

30

180

12

20

240

60 Hz

120

80

400

50 Hz

120
8

Hp

8
6

300

180

12

14

14

220

200

40

16

16

100

240

20

TEMPERATURE INCREASE

p In Hg

K07-TD

cfm

In WG

12

200

p In Hg

14

100

ABSORBED POWER

220
In WG

p In Hg

16

K12-TD

1
0
0

K10-TD

20

1
0

K08-TD

2
20

K11-TD

40

K12-TD

K10-TD

K08-TD

K09-TD

K07-TD

40

In WG

K11-TD

K09-TD

K07-TD

1/2

1/2

20
0
0

20

40

60

80

100

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

120

140

160

180

200 F

Hp

53

54

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

SCL 06
06 SERIES

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SN 2674-0 1/2

STANDARD FEATURES
- Low weight cast aluminum construction.
- Quiet operation with integral inlet and
outlet muffling.
- Recognized TEFC - cURus motor.
- High efficiency / low noise impeller
design.
- No lubrication / maintenance required.
H
- Allowed ambient: +5 F to +104 F.
- Mountable in any plane.

1NPT
3.15
0.59 1.38

P version

0.43

2.95

4.13
7.10

OPTIONS
- Special voltages.
- Surface treatment or plating.
- Gas tight sealing.
- Special designs available.

7.6
8.7

M5

1.06

ACCESSORIES
- Inlet and/or inline filters.
- Additional inlet/outlet silencers.
- Safety valves.
- Flow converting devices.
- Optional connectors

8.6

4.56
4.37
3.38

4.64

5.35 DIA
M5
Dimensions in inches.
Dimension for reference only.

Model

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm
06

39

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

32

1/3
1/2

1/2

Maximum
differential pressure
p ( In Hg)
60 Hz
50 Hz
3500 rpm 2900 rpm
2.7
3.5

2.4

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

58.7
59.0

58.0

10.60
10.60

18.30
18.50

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS- VACUUM 55

SCL 06
06 SERIES
SN 2674-0 2/2
50 Hz

In WG

p In Hg

4.0

40

60 Hz

In WG

p In Hg

60

2.5

50

1/2

1/2

3.5

30
3.0

40

CAPACITY

1/3

2.5
30
2.0

1.5

1.5

20

20

10

1.0
0.5

10
0.5

0
20

30

60

3,5
3,0

40

2,5
30
2,0
1,5

10

20

30

40

40

60 Hz

ABSORBED POWER

4,0

40 cfm

20

1,0
10

2.5

cfm

50 Hz

In WG

10

In WG

p In Hg

p In Hg

30
2.0

1.5

20

1.0
10
0.5

0,5
0

0
0.2

0.3

60

3,5
3,0

60 Hz

40

2,5
2,0
1,5

30

20

1,0
10
0,5
0

10

20

30

40

50

60

70

80

90

100 F

0.05

0.1

0.15

0.2

2.5

0.3 Hp

0.25

40

50 Hz

30
2.0

1.5

20

1.0
10
0.5

0
0

Hp

TEMPERATURE INCREASE

4,0

0.5

0.4

In WG

0.1

In WG

p In Hg

p In Hg

0
0

10

20

30

40

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

50

60

70

80 F

56

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

SCL 10DL / 15DH


DH SERIES

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SN 2198-2 1/2

STANDARD FEATURES
- Low weight cast aluminum construction.
- Quiet operation with integral inlet and outlet
muffling.
- Recognized TEFC - cURus motor.
- High efficiency / low noise impeller design.
- No lubrication / maintenance required.
- Allowed ambient: +5 F to +104 F.
- Mountable in any plane.

OPTIONS
- Remote drive models (belt or coupling).
- Special voltages.
- Surface treatment or plating.
- Gas tight sealing.
- Special designs available.

n
o
H

ACCESSORIES
- Inlet and/or inline filters.
- Additional inlet/outlet silencers.
- Safety valves.
- Flow converting devices.
- Optionals connectors

s
f
e

Dimensions in inches.
Dimension for reference only.

Model

10DL

8.66

15DH

9.84

Model

10.08

9.06

0.91

8.27

7.09

1/2" NPT

2.28

0.35

4.72

5.67

3.54

0.10

11.26

10.16

1.18

8.27

7.09

3/4" NPT

2.52

0.35

4.72

5.67

4.72

0.10

Maximum
flow

Installed
power

cfm

Hp

Maximum
differential pressure

p ( In Hg)

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

10DL

21

18

1/3
1/2

1/3
1/2

4.4
6.3

4.4
4.9

63.7
64.0

61.7
62.0

12.20
12.76

21.80
23.50

15DH

35

29

3/4
1

3/4
1

7.2
8.1

7.7
8.1

63.7
64.0

61.7
62.0

14.25
15.75

32.50
40.00

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS- VACUUM

SCL 10DL / 15DH


DH SERIES
p In Hg

60 Hz
1

120
8

50 Hz

In WG

120
In WG

p In Hg

SN 2198-2 2/2

1
3/4

3/4

100

100
7

CAPACITY

1/2

80

1/3

60

40

2
15DH
20
1

10DL

0
10

20

30

40

ABSORBED POWER

15DH
80

10DL

5
60
4
3

40

80

10DL

40

0,6

0,8

TEMPERATURE INCREASE

15DH

10DL

60

40

2
20
1
0

20

40

60

80

100

0,4

0,6

0,8

120 F

Hp

50 Hz

15DH
80

5
60
4
3

10DL
40

2
1
0

0,2

120

60 Hz

80

1 Hp

p In Hg

0,4

In WG

p In Hg

15DH

60

0
0,2

50 Hz

cfm

20

120

40

30

20

20

7
6

1
0

10

120

60 Hz

In WG

p In Hg

120

cfm

p In Hg

10DL

In WG

40

15DH
20

1/3

60

1/2

80

In WG

20

0
0

20

40

60

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120 F

57

58

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL 20DH / 30DH / 40DH


DH SERIES
SN 2465-1 1/2

STANDARD FEATURES
- Low weight cast aluminum construction.
- Quiet operation with integral inlet and outlet
muffling.
z
- Recognized TEFC - cURus motor.
- High efficiency / low noise impeller design.
- No lubrication / maintenance required.
t
- Allowed ambient: +5 F to +104 F.
- Mountable in any plane.
OPTIONS
- Remote drive models (belt or coupling).
- Special voltages.
3x120
- Surface treatment or plating.
u
- Gas tight sealing.
- Special designs available.
ACCESSORIES
- Inlet and/or inline filters.
- Additional inlet/outlet silencers.
- Safety valves.
- Flow converting devices.
- Optional connectors

b
c
d
m

s
l

f
q

p1

Dimensions in inches.
Dimension for reference only.

Model
20DH
30DH
40DH

Model

11.42 12.20 6.50


12.60 13.66 7.36
13.78 14.57 7.68

1.77 9.06 8.27


2.09 10.63 9.64
2.09 10.63 9.65

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm

1 NPT
1 NPT
1 NPT

3.54
4.13
4.13

0.39
0.39
0.39

5.90
7.28
7.28

Maximum
differential pressure
p ( In Hg )
60 Hz
50 Hz
3500 rpm 2900 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm
1
1

6.2
8.1

p1

7.67 13.98 0.71


9.25 16.54 0.71
9.25 17.32 0.71

1.77
2.17
2.17

0.79
0.79
0.79

M6
M6
M8

5.91
7.09
8.86

0.31
0.67
-

Noise level
Lp dB (A)

Overall
dimensions

(1)

Weight

60 Hz
3500 rpm

50 Hz
2900 rpm

Inches

Lbs

6.9
7.4

67.7
68.0

64.7
65.0

13.78
13.78

44.00
47.30

20DH

48

42

1
1

30DH
40DH

70

61

10.3

8.9

69.7

67.7

15.36

58.30

98

85

11.1

10.3

74.7

71.7

16.93

75.00

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS- VACUUM 59

SCL 20DH / 30DH / 40DH


DH SERIES
SN 2465-1 2/2

140

10

11

140

120
1 1/2

120

100

1 1/2

100

80

CAPACITY

80

5
60

60
4

10

50 Hz

In WG

p In Hg

11

160

60 Hz

In WG

p In Hg

160

40

40
40DH

2
40DH

20
30DH

30DH
20
20DH

20DH
0

0
20

40

60

80

100

120
100

80

40DH
30DH
20DH

60
40

2
1
0

1.5

2.5

4
3
2

120

30DH

40DH

100
80

20DH

60
40
20

11

60
40
20
0

120

7
6
5
4
3
2
1
0

0
0

20

40

60

80

100

120

140 F

cfm

80

10

100

40DH

0.5

1.5

2.5 Hp

160

2
1

80

30DH

20DH

60 Hz

5
4

60

50 Hz

100

3.5 Hp

8
7

120

0
0.5

TEMPERATURE INCREASE

In WG

p In Hg

10

10

160
11

11

20

40

p In Hg

20

160

60 Hz

8
7

In WG

cfm

p In Hg

10

In WG

p In Hg

160
11

120

In WG

ABSORBED POWER

50 Hz

40DH

100
30DH

20DH
80
60
40
20
0
0

20

40

60

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120 F

60

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K03 / K04 / K05 / K06


MS SERIES - GOR/GVR RANGE
SN 2582-0 1/2

TECHNICAL CHARACTERISTICS

GOR Range

- Aluminium alloy construction


- Smooth operation
- High efficiency impeller
- Maintenance free
- Mountable in any position

GVR Range

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
- Inlet and/or inline filters
- Additional inlet/outlet silencers
- Safety valves
- Flow converting device
- Optional connectors

For dimensions, please refer to drw:


- GOR range: SI 1852
- GVR range: SI 1946

Model

Maximum
flow
cfm

K03-MS
K04-MS

Installed
power

50 Hz
2900 rpm

52

43
81

156

129

179

60 Hz
3500 rpm

50 Hz
2900 rpm
3.7

(1)

Lbs
GOR GVR

61.0

59.0

22.00 17.60
27.60 22.00

4.7
4.3

2
3

NEMA 56C
NEMA 56C

6.3
6.6

5.9

64.0
64.2

61.8

NEMA 143-5TC

3.8

5.2

69.5

67.5

NEMA 143-5TC
NEMA 182-4TC

6.6

63.8

7.1

8.1
3.7

NEMA 182-4TC

6.3

NEMA 182-4TC

9.6

(2)

50 Hz
2900 rpm

NEMA 56C

NEMA 143-5TC
NEMA 182-4TC
NEMA 182-4TC

Weight

60 Hz
3500 rpm

NEMA 56C

3
216

Dp ( In Hg )

Noise level
Lp dB (A)

3/4

K06-MS

differential pressure

2
K05-MS

SCL Kxx-MS GOR-C

Maximum
Size

Hp

60 Hz
3500 rpm

98

SCL Kxx-MS GOR-A

69.8

67.8

70.4
4.8
8.1

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

72.0
72.6
72.9

70.0
70.6

35.00 28.00
34.50 27.00
46.00 38.40
40.80 38.00

REGENERATIVE BLOWERS - VACUUM 61

SCL K03 / K04 / K05 / K06


MS SERIES - GOR/GVR RANGE
SN 2582-0 2/2

p In Hg

In WG

p In Hg

120

60 Hz
7 1/2

120

50 Hz

In WG

140
10

100
3

8
100
7

6
3

5
3/4

60

1 1/2

4
3/4

20
K03-MS

K05-MS

0
50

100

150

200

K04-MS

60
K03-MS
40

7
6
5

140

150

200 cfm

K06-MS
K05-MS

60

K04-MS

K03-MS

40

2
20

K05-MS

100
K04-MS

80
60

K03-MS

40
20
0

8
7
6

80

20

40

60

80

100

120

140

160

180

200 F

Hp

50 Hz
K06-MS
K05-MS

5
60

K04-MS

4
3

40

K03-MS

2
20
1
0

120

60 Hz

1
0

80

Hp

K06-MS

4
3

In WG

0
1

In WG

p In Hg

100

50 Hz

0
0

10

50

p In Hg

K06-MS

TEMPERATURE INCREASE

20

In WG

K05-MS

p In Hg

K06-MS

ABSORBED POWER

K05-MS

120

5
4

60 Hz

80

K04-MS

250 cfm

140

100

K03-MS

K06-MS

In WG

p In Hg

K04-MS

40

40

60

20

10

1 1/2

80

80

CAPACITY

0
0

20

40

60

80

100

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

120

140

160

180

200 F

62

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 / K12


MS SERIES - GOR/GVR RANGE
SN 2135-2S 1/2

GVR Range

GOR Range

TECHNICAL
CHARACTERISTICS
Aluminium alloy construction
Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
-

SCL Kxx-MS GOR-C

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

For dimensions, please refer to drw:


GOR range: SI 1873
GVR range: SI 1920

Model

Maximum
flow
cfm
60 Hz
3500 rpm

SCL Kxx-MS GOR-A

Installed
power
Hp

50 Hz
2900 rpm
5

K07-MS

294

243

7
5
7

K08-MS

381

316

10
15
7

K09-MS

471

390

556

460

K12-MS

650

726

539

602

NEMA 213-5TC
NEMA 182-4TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 254-6TC
NEMA 182-4TC
NEMA 213-5TC

Noise level
Lp dB (A)
(1)

Weight
(2)

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Lbs

5.1

6.3

78.0

76.0

110.50

9.6

8.8

78.3

76.3

2.8

3.8

78.8

76.8

5.0

6.6

79.1

77.1

8.5
10.3

79.7

110.50
127.00
127.00
127.00
127.00

79.4
9.2

110.50

77.4

127.00
130.60

3.7

4.6

79.3

77.3

133.40
133.40

NEMA 213-5TC

5.9

7.0

79.6

77.6

133.40

15

NEMA 213-5TC
NEMA 254-6TC

10.3

9.6

80.1
80.4

78.1

133.40
137.00

2.2

3.7

79.4

77.4

4.4

5.9

79.7

77.7

10
15

K11-MS

NEMA 182-4TC
NEMA 182-4TC

Maximum
differential pressure
Dp ( In Hg )

10

7
K10-MS

Size

SCL Kxx-MS GOR-B

NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 254-6TC

8.1

9.6

80.2

78.2

NEMA 254-6TC

10.3

10

NEMA 213-5TC
NEMA 213-5TC

2.9

3.9

82.0

80.0

5.9

7.1

82.5

80.5

NEMA 254-6TC

20

NEMA 254-6TC

9.2

25

NEMA 284-6TSC

10.3

15

NEMA 213-5TC
NEMA 254-6TC

3.8

20

NEMA 254-6TSC

6.3

25

NEMA 284-6TSC

8.8

30

NEMA 284-6TSC

10.3

80.5

9.6
6.6

83.0
83.8
83.5

81.0
81.5

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

87.2
87.6

151.00
170.00
170.00
176.40
176.40
170.00
177.70
184.10
184.10

84.3
9.6

147.30
147.30
147.30
151.00

20

15

147.30

82.3

177.70
177.70

REGENERATIVE BLOWERS - VACUUM 63

SCL K07 / K08 / K09 / K10 / K11 / K12


MS SERIES - GOR/GVR RANGE

SN 2135-2S 2/2

10

140

15

15

20

25

30

50 Hz

In WG

10
p In Hg

11

140

60 Hz

In WG

p In Hg

160

15

15

20

20

10

120

7 1/2

7 1/2

20

120

25
10

100
15

100

80

15

10
5

7 1/2

60

K09-MS

300

400

500

600

700

K12-MS
K11-MS
K10-MS

100
K09-MS
80

K08-MS
K07-MS

60
40

15

20

100

K12-MS

K11-MS

80

K07-MS

3
2
1
0

60
40
20
0

9
8
7
6

20

40

60

80

100

120

140

160

180 F

300

400

500

600

700 cfm

K11-MS

K09-MS

K07-MS

100
K08-MS

K10-MS

K12-MS

80
60
40
20
0
2

4
3

10

12

14

140

18 Hp

16

50 Hz
K09-MS
K08-MS

K10-MS

100
K11-MS
80

K07-MS
60
K12-MS
40

2
1
0

200

50 Hz

10

K08-MS

100

140

25 Hp

K10-MS

K11-MS

K09-MS

60 Hz

K09-MS

5
4

p In Hg

10

0
5

TEMPERATURE INCREASE

In WG

p In Hg

120

K12-MS

160

10

20

11

10

60 Hz

p In Hg

120

800 cfm

In WG

200

K10-MS

In WG

100

ABSORBED POWER

In WG

p In Hg

K07-MS
0

10

K08-MS
20

K12-MS

160

40

K11-MS

K10-MS

K08-MS

7 1/2

10

10
7 1/2

K07-MS

20

11

7 1/2

60

15

10

7 1/2

40

80

10

CAPACITY

20

15

15

10
7 1/2

20
0
0

20

40

60

80

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

100

120

140

160 F

64

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K05 / K06


TS SERIES - GOR/GVR USA RANGE
SN 2688-0 1/2

TECHNICAL CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any plane
G1/8'' female thread on both suction
and discharge silencer port flanges.

GVR Range

GOR Range
G 1/8

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

G 1/8

SCL Kxx-TS GOR-C

SCL Kxx-TS GOR-A

SCL Kxx-TS GOR-B

SCL Kxx-TS GOR-C

For dimensions, please refer to drw:


- GOR range: SI 2123
- GVR range: SI 2135

Model

Maximum
flow
m/h
60 Hz
3500 rpm

50 Hz
2900 rpm

K05-TS

290

241

K06-TS

400

331

Installed
power
Hp

Size

Maximum
differential pressure
p ( in Hg )
60 Hz
3500 rpm

5.0
7.5

NEMA 182-4TC

7.5
10
15

NEMA 213-5TC

50 Hz
2900 rpm

Noise level
Lp dB (A)

Weight
(2)

(1)

60 Hz
3500 rpm

50 Hz
2900 rpm

4.4

6.3

75.1

73.1

7.4

6.7

77.1

75.1

4.1

5.7

77.1

75.1

5.9
7.8

7.4

77.4

75.4

78.0

76.0

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Lbs
GOR
GVR
72.75

68.35

112.45 108.00

REGENERATIVE BLOWERS - VACUUM 65

SCL K05 / K06


TS SERIES - GOR/GVR RANGE
SN 2688-0 2/2

15

100

50 Hz

In WG

p In Hg

120

60 Hz

In WG

p In Hg

120

100

7 1/2

10

7
7 1/2
5

10

80

CAPACITY

5
60

5
7 1/2

80

7 1/2

5
60
4

40

40

K06-TS
2

K06-TS
2

K05-TS
20

0
0

100

200

300

400

80

60

K06-TS
K05-TS

40

2
20

10

11

300

350

400 Scfm

K06-TS

40

2
20

K05-TS

60

40

20
1
0

p In Hg

K06-TS
80

8
7
6

80

20

40

60

80

100

120

140 F

10 Hp

50 Hz

K06-TS
K05-TS

5
4
3

60

40

2
20
1
0

120

60 Hz

250

K05-TS

TEMPERATURE INCREASE

200

50 Hz

60

12 Hp

5
4

80

0
1

In WG

p In Hg

120

150

100

1
0

In WG

50

120
8

In WG

60 Hz

ABSORBED POWER

In WG

p In Hg

120
8

500 Scfm

p In Hg

K05-TS
20

0
0

20

40

60

Curves refer to air at 20C temperature, measured at inlet port and 1013 mbar (abs) atmospheric backpressure.
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

80

100

120

140 F

66

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 / K12


TS SERIES - GOR/GVR RANGE
SN 2165-3 1/2

TECHNICAL
CHARACTERISTICS
-

GVR RANGE

GOR RANGE
G 1/8

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
G1/8 female thread on both
suction and discharge silencer
port flanges

G 1/8

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

SCL Kxx-TS GOR-C

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

For dimensions, please refer to drw:


GOR range: SI 1879
GVR range: SI 1880

Model

Maximum
flow
cfm
60 Hz
3500 rpm

SCL Kxx-TS GOR-A

Installed
power

588

487

780

Lbs

NEMA 182-4TC

2.6

4.4

84.5

82.5

160.90

NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
(3)
NEMA 254-6TC
(3)
NEMA 254-6TC

2.6
4.4
8.1
8.1
8.8

4.4
6.6
8.1
8.1
8.1

84.5
84.8
85.4
85.4
85.9

82.5
82.8
83.4
83.4
83.4

160.90
160.90
160.90
167.60
167.60

NEMA 213-5TC
NEMA 213-5TC
(3)
NEMA 254-6TC
(3)
NEMA 254-6TC
(3)
NEMA 284-6TSC

2.7
5.5
5.5
7.4
9.6

4.7
7.7
7.7
8.8
8.8

81.2
82.9
82.9
84.8
87.0

79.2
80.9
80.9
80.8
80.8

172.00
172.00
180.80
180.80
174.20

NEMA 213-5TC
(3)
NEMA 254-6TC
(3)
NEMA 254-6TC
(3)
NEMA 284-6TSC
(3)
NEMA 284-6TSC
(3)
NEMA 324-6TSC

3.8
3.8
5.9
8.1
8.8
9.6

5.5
5.5
7.9
8.8
8.8
8.8

82.2
82.2
84.1
86.1
88.1
90.1

80.2
80.2
82.1
84.1
84.1
84.1

202.80
208.30
208.30
205.00
205.00
220.50

20
25
30
40

NEMA 213-5TC
(3)
NEMA 254-6TC
(3)
NEMA 254-6TC
(3)
NEMA 284-6TSC
(3)
NEMA 284-6TSC
(3)
NEMA 324-6TSC

3.0
3.0
4.8
5.9
7.4
10.3

4.7
4.7
6.6
8.1
9.6
9.6

89.1
89.1
89.4
89.7
90.0
90.3

87.1
87.1
87.4
87.7
88.0
88.0

209.40
216.10
216.10
211.60
211.60
227.10

NEMA 284-6TSC
NEMA 284-6TSC
(3)
NEMA 324-6TSC
(3)
NEMA 324-6TSC

3.7
5.1
7.4
10.3

6.5
8.1
9.6
9.6

90.7
91.3
91.9
92.5

88.7
89.3
89.9
89.9

251.30
251.30
269.00
269.00

NEMA 284-6TSC
(3)
NEMA 324-6TSC
(3)
NEMA 324-6TSC

3.3
5.2
8.1

5.9
8.8
-

91.9
92.5
93.1

89.9
90.5
-

249.10
266.80
266.80

10

15

20
25
30
40
15

K10-TS

1093

906

(2)

50 Hz
2900 rpm

15
941

Weight

60 Hz
3500 rpm

20
25

K09-TS

(1)

50 Hz
2900 rpm

10
592

Noise level
Lp dB (A)

60 Hz
3500 rpm

20

715

differential pressure

p ( In Hg )

50 Hz
2900 rpm

15

K08-TS

Maximum
Size

Hp

7
K07-TS

SCL Kxx-TS GOR-B

K11-TS

1254

1039

25
30
40
50

K12-TS

1410

1168

30
40
50

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor
(3) Not applicable on SCL Kxx - GVR
- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - VACUUM 67

SCL K07 / K08 / K09 / K10 / K11 / K12


TS SERIES - GOR/GVR RANGE
SN 2165-3 2/2

140

40

50

10
25

50 Hz

In WG

10
p In Hg

11

140

60 Hz

In WG

p In Hg

160

120

20

25

40

40
15

8
120

40

30

20

20

30

25

30

15

100
15

25

100

50

20

30

7
10

40

80

20

25

15
30

40

20

60

CAPACITY

30

5
10

60

15

7 1/2

15

25

30

25

80
15

10

20

40

15

40

10

7 1/2

2
2
K08-TS

20

K10-TS

20

K12-TS
K11-TS

K09-TS

K07-TS

K07-TS
0

0
200

400

600

800

1000

1200

1400

160

K09-TS

K08-TS

80

K11-TS

K10-TS

K12-TS

5
4
3

60
40

In WG

p In Hg

120

20

30

40

1000

1200 cfm

50 Hz

100

K08-TS
K07-TS

K10-TS

K12-TS

K11-TS

K09-TS

80
60
40

K10-TS
100

K07-TS

K11-TS
K08TS

80
K12-TS
K09-TS

60
40
20
0

10

140

9
8
7

20

40

60

80

100

120

140

160 F

10

15

20

25

30

35

40 Hp

50 Hz
K10-TS
K11-TS

100

K09-TS
K12-TS

K08-TS

80

5
4
3

K07-TS

60
40

2
20
1
0

50 Hp

2
1

60 Hz

5
4

0
10

8
7

800

20

160

600

10

400

11

20

TEMPERATURE INCREASE

200

8
7

p In Hg

K07-TS

100

K11-TS

K09-TS

140

In WG

120

10
p In Hg

60 Hz

K12-TS

1600 cfm

ABSORBED POWER

In WG

p In Hg

10

K10-TS

In WG

11

K08-TS

0
0

20

40

60

80

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

100

120

140

160

180 F

68

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07R / K08R / K09 / K10 / K11 / K12


MD SERIES - GOR/GVR RANGE
SN 2150-1 1/2

GVR Range

GOR Range

TECHNICAL
CHARACTERISTICS
Aluminium alloy construction
Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

SCL Kxx-MD GOR-C

SCL Kxx-MD GOR-A

For dimensions, please refer to drw:


GOR range: SI 1918
GVR range: SI 1919

Model

Maximum
flow
cfm
60 Hz
3500 rpm

Installed
power

129

107

5
168

139

7
10
5

K09-MD

221

differential pressure

p ( In Hg )
60 Hz
3500 rpm

50 Hz
2900 rpm

K08R-MD

Maximum
Size

Hp

3
K07R-MD

SCL Kxx-MD GOR-B

183

7
10
7

K10-MD

275

228

K11-MD

306

254

K12-MD

336

278

10
15
10
15
15
20

NEMA 56C
NEMA 143-5TC
NEMA 182-4TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 182-4TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 182-4TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 254-6TC
NEMA 213-5TC
NEMA 254-6TC
NEMA 254-6TC

50 Hz
2900 rpm

Noise level
Lp dB (A)
(1)

60 Hz
3500 rpm

50 Hz
2900 rpm

5.0

6.4

72.5

70.5

10.7

12.5

73.5

71.5

13.2

13.2

74.0

72.0

5.9

8.1

75.7

73.7

11.9

13.2

76.1

74.1

13.2

76.5

3.7

5.7

76.4

74.4

8.8

10.5

77.5

75.5

13.6

13.2

79.0

77.0

6.3

8.1

80.4

78.4

10.3
14.7

12.1
14.0

80.7
81.3

78.7
79.3

7.4

9.2

80.7

78.7

14.0

14.0

81.3

79.3

7.4

13.2

82.2

80.2

13.2

82.5

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

Weight
(2)

Lbs
112.00
112.00
113.80
113.80
113.80
130.30
130.30
130.30
130.30
138.50
138.50
138.50
138.50
125.40
152.40
152.40
152.40
175.70
175.70
182.10
183.40
189.80
189.80

REGENERATIVE BLOWERS - VACUUM 69

SCL K07R / K08R / K09 / K10 / K11 / K12


MD SERIES - GOR/GVR RANGE

13
12

15
10

180

7 1/2

20

12

10

7 1/2

50 Hz

15

10

15

160
7 1/2

140

10

9
120

7 1/2

8
7

7 1/2

11

7 1/2

140

13

15

10

10

160

11
10

15

14

In WG

14

200

60 Hz

p In Hg

15

220

CAPACITY

16

In WG

p In Hg

SN 2150-1 2/2

100

15

10

7 1/2

8
100
3

7 1/2

80

10

120

80

5
5

60

60

40

K07R-MD

K11-MD

300

220

ABSORBED POWER

60 Hz
K11-MD
K10-MD

160

K12-MD

K09-MD

140

K08R-MD

120

K07R-MD

100
80
60
40

14
13
12
11

140

9
8

120

100

80

4
3
2
1

0
6

10

12

14

16

220
In WG

K10-MD

K11-MD

K07R-MD

140

K08R-MD

120
K12-MD

100
80
60
40
20
0
20

40

60

80

100

120

140

160

180

200 F

200

300

50 Hz

K10-MD

K12-MD

K09-MD
K08R-MD
K07R-MD

40
20
0
2

10

12
11
10

140

9
8

120

100

80

5
4
3
2
1

50 Hz

K11-MD
K10-MD

14 Hp

12

200
14
13

cfm

K11-MD

0
0

100

60

20 Hp

60 Hz

K09-MD

160

18

p In Hg

K11-MD

200

10

K12-MD

K10-MD
K09-MD

0
0

20
2

K07R-MD

400 cfm

p In Hg

200

In WG

p In Hg
p In Hg

100

K08R-MD

20
1
0

16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0

K09-MD

K12-MD

0
0

16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0

K10-MD

In WG

1
0

K08R-MD

20

40

In WG

TEMPERATURE INCREASE

K08R-MD

K09-MD
K07R-MD
K12-MD

60
40
20
0
0

20

40

60

80

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

100

120

140

160

180 F

70

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K07 / K08 / K09 / K10 / K11 / K12


TD SERIES - GOR RANGE
SN 2180-3 1/2

TECHNICAL
CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
Mountable in any position
G1/8 female thread on both
suction and discharge silencer
port flanges

G 1/8

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
-

Inlet and/or inline filters


Additional inlet/outlet silencers
Safety valves
Flow converting device
Optional connectors

For dimensions, please refer to drw: S I 1971

Model

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm
7

K07-TD

296

245

10
15
10

K08-TD

368

305

15
15

K09-TD

467

387

20
25
15

K10-TD

K11-TD

K12-TD

571

642

716

Maximum
Size

473

532

593

NEMA 182-4TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 254-6TC
NEMA 213-5TC
NEMA 213-5TC
NEMA 254-6TC
NEMA
NEMA
NEMA
NEMA

213-5TC
254-6TC
254-6TC
284-6TSC

NEMA 213-5TC
NEMA 254-6TC

differential pressure

Noise level
Lp dB (A)

p ( In Hg )

(1)

Weight
(2)

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

Lbs

6.6

9.6

78.6

76.6

156.50

9.9
13.2

78.9
12.5

79.5

156.50
76.9

156.50
169.80
169.80
178.60

160.90

7.0

10.3

79.3

77.3

12.5

12.5

79.9

77.9

7.7

11.4

82.2

80.2

11.7
13.2

12.5

82.5
82.8

80.5

6.3

9.6

85.9

83.9

20

NEMA 254-6TC

9.6

25

NEMA 284-6TSC

13.2

20

NEMA 254-6TC

6.6

25

NEMA 284-6TSC

9.6

30

NEMA 284-6TSC

11.0

40

NEMA 324-6TSC

12.5

25
30
40

NEMA 284-6TSC
NEMA 284-6TSC
NEMA 324-6TSC

6.3
8.8
12.5

13.2
10.3

86.2
86.5
86.7

84.2
84.7

87.2
13.2

87.7

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

87.5
88.0
88.4

202.80
209.50
209.50
205.00
246.80
244.70

85.2

88.1
10.3
13.2
-

196.20
201.70
201.70
198.40

244.70
264.50

85.5
86.0
-

242.5
242.5
262.3

REGENERATIVE BLOWERS - VACUUM

SCL K07 / K08 / K09 / K10 / K11 / K12


TD SERIES - GOR RANGE
SN 2180-3 2/2
200

60 Hz

15

12

40

160

50 Hz

14
13

In WG

25

25

15

p In Hg

13

In WG

p In Hg

200
14

20

40

10

12

20

15

25

30

20

160
15

11
140

10

10
20

25

120

30

15

100
7

10
7 1/2

20
25

15

80

100
7
6

60

4
3

40

2
1

0
400

500

600

K09-TD

K12-TD

40

15

20

25

120

8
7

100

80

K10-TD

K11-TD
K09-TD

60
40
20
0

p In Hg

4
3
2

p In Hg

14
13
12

20

40

60

80

100

120

140

160

500

600

180 F

700

K07-TD

120
100

K11-TD

K09-TD

K08-TD K10-TD

K12-TD

80
60
40
20
0
5

10

15

20

30 Hp

25

50 Hz

160

10

140

120

8
7

100

80

5
4

60

3
2
1

cfm

140

K07-TD

11

0
0

400

200

K12-TD

K08-TD

300

50 Hz

TEMPERATURE INCREASE

p In Hg

6
5

60 Hz

In WG

200

160

Hp

K07-TD
140

1
0

35

30

160

10

3
2

8
7

11

10
9

1
0

200

13
12
11

20

10

100

200

60

K12-TD

K11-TD

K09-TD

0
0

14

K11-TD

K10-TD

K08-TD

K10-TD

K07-TD

cfm

ABSORBED POWER

K07-TD

13
12

800

60 Hz

120

80

14

700

140

100

1
0

300

160

6
5
3
2

200

200

8
7

100

K08-TD

20
1

K11-TD

In WG

p In Hg

10
9

K12-TD

K10-TD
K09-TD

K07-TD

13
12
11

40

2
K08-TD

20

14

80

5
60

15

120

25

In WG

20

10

In WG

140
7 1/2

CAPACITY

10

11

30

K08-TD
K11-TD
K10-TD
K09-TD
K12-TD

40
20
0
0

20

40

60

80

Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
Values for flow, power consumption and temperature rise: +/-10% tolerance.
Data subject to change without notice.

100

120

140

160

180 F

71

72

FPZ, Inc

REGENERATIVE BLOWERS - VACUUM

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

SCL K09 / K10 / K11


TT SERIES - GOR RANGE
SN 2784-3 1/2

TECHNICAL
CHARACTERISTICS
-

Aluminium alloy construction


Smooth operation
High efficiency impeller
Maintenance free
G1/8 female thread on both
suction and discharge silencer
port flanges

G 1/8

OPTIONS
- Special voltages (IEC 38)
- Surface treatments

ACCESSORIES
- Inlet and/or inline filters
- Additional inlet/outlet silencers
- Optional connectors

For dimensions, please refer to drw:

SI 2180
Model

Maximum
flow

Installed
power

cfm

Hp

60 Hz
3500 rpm

50 Hz
2900 rpm

K09-TT

423

351

K10-TT

526

436

25
30
25

K11-TT

597

Maximum
Size

495

30

NEMA 284-6TSC
NEMA 284-6TSC

Noise level
Lp dB (A)

differential pressure

p ( In Hg )

Weight
(2)

(1)

60 Hz
3500 rpm

50 Hz
2900 rpm

60 Hz
3500 rpm

50 Hz
2900 rpm

12.5
15.5

15.5
-

86.9
87.2

84.9
-

14.7

85.5

13.2

16.2

87.8

85.8

Lbs
354
365

40

NEMA 324-6TSC

16.2

88.1

380

30

NEMA 284-6TSC

14.7

85.8

430

40

NEMA 324-6TSC

17.0

17.0

88.1

86.1

434

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.
(2) Value is refered to weight of the machine without electric motor

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request.
- Ambient temperature from +5 to +104F.
- Specifications subject to change without notice.

REGENERATIVE BLOWERS - VACUUM 73

SCL K09 / K10 / K11


TT SERIES - GOR RANGE
SN 2784-3 2/2

40

17
40

30

15

14

12

30

180

13

25
160

11
10
9

12

140
120

10
9

100

K11-TT

80
60

4
K09-TT

40

1
400

500

600

700

260

160
140
120
K11-TT

100
80
K10-TT
60
K09-TT
40
20

200

180
160
K11-TT
K10-TT

120
100

K09-TT

80
60

p In Hg

ABSORBED POWER

200

140

40
20
0
15

20

260

25

30

35

In WG

60 Hz

200

K09-TT
K11-TT

180
160
140
120

K10-TT

100
80
60
40
20
0
0

20

40

60

80

19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0

100 120 140 160 180 200 220 240 F

300

500

600 cfm

50 Hz

200
180
160

K11-TT

140

K10-TT

120
K09-TT

100
80
60
40
20
0
0

19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0

400

260

40 Hp

p In Hg

10

TEMPERATURE INCREASE

cfm

60 Hz

In WG

p In Hg

300

p In Hg

180

0
200

19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0

30

2
20

19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0

25

K10-TT

2
1

25
200

5
4

30

11

8
7

220

14

CAPACITY

13

40

17
16

200

50 Hz

In WG

15

220

18

260

10

15

20

260

30 Hp

25

50 Hz

In WG

16

19

In WG

60 Hz
p In Hg

18

260
In WG

p In Hg

19

K09-TT

200

K11-TT

180
160
K10-TT

140
120
100
80
60
40
20
0
0

20

40

60

80

100 120 140 160 180 200 220 240 F

- Curves refer to air at 68 F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).
- Values for flow, power consumption and temperature rise: +/-10% tolerance.
- Data subject to change without notice.

74

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

Installation Guide

Pressure

11

Vacuum

10
8

4
7

11

6
7

From a wide range of accessories, the


customer can select the most suitable for
their application. In all cases, FPZ suggests to
install an inlet filter and safety valve on every
machine
9
10
8
5
6
2

1 - Cartridge filter
2 - Inline filter
3 - Filter manifold
4 - Relief valve
5 - Vacuum valve
6 - Check valve
7 - Control valve
8 - Pressure / Vacuum gauge
9 - Sleeve
10 - Flexible hose
11 - Additional silencer

FPZ, Inc

75

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

Safety Valves
SS1209

The following table is a guide to select the appropriate safety valve. The selections in the table are based on blowers operating
at 60 Hz - for 50 hz applications refer to the safety valve data sheets. To select the appropriate safety valve, determine the
blower model, horsepower, and whether it is to be used for vacuum or pressure service. If it is desirable to have the valve
activate at lower pressures than the maximum rated pressure or vacuum of the blower, a different safety valve might be required
(refer to safety valve data sheets). In some cases, two valves are required. FPZ valves are supplied uncalibrated. All safety
valves included detailed instructions on how to calibrate and install the valve.
Single Stage Blowers

Two Stage Blowers

HP

Safety Valve
Vacuum

Safety Valve
Pressure

Model

HP

Safety Valve
Vacuum

Safety Valve
Pressure

K03-MS

3/4

VRL6

VRL6

15DH

ALL

VRL6

VRL6

K04-MS

ALL

VRL6

VRL6

20DH

ALL

VRL6

VRL6

K05-MS

ALL

VRL6

VRL6

30DH

ALL

VRL6

VRL6

K06-MS

VRL6

VRL8

40DH

ALL

VRL6

VRL6

K06-MS

VRL6

VRL6

K07-MD

VRL6

VRL6

K06-MS

5 1/2

VRL6

VRL6

K07-MD

VRL6

VRL6

K06-MS

6 1/5

VRL6

VRL6

K07-MD

5 1/2

VRL6

VRL6

K07-MS

VRL8

VRL8

K07-MD

7 1/2

VRL6

VRL6-HP

K07-MS

5 1/2

VRL6

VRL8

K08-MD

5 1/2

VRL6

VRL6

K07-MS

7 1/2

VRL6

VRL6

K08-MD

7 1/2

VRL6

VRL6

K07-MS

10

VRL6

VRL6

K08-MD

10

VRL6

VRL6

K08-MS

5.5

VRL8

VRL9

K08-MD

15

VRL6-HP

K08-MS

7 1/2

VRL8

VRL8

K09-MD

5 1/2

VRL8

VRL8

K08-MS

10

VRL6

VRL8

K09-MD

7 1/2

VRL6

VRL6

K08-MS

15

VRL6

VRL6

K09-MD

10

VRL6

VRL6

K09-MS

7 1/2

VRL9

VRL9

K09-MD

15

VRL6-HP

K09-MS

10

VRL8

VRL8

K10-MD

7 1/2

VRL8

VRL8

K09-MS

15

VRL6

VRL8

K10-MD

10

VRL6

VRL6

K09-MS

20

VRL6

VRL6

K10-MD

15

VRL6

VRL6

K10-MS

7 1/2

VRL9

VRL9

K10-MD

20

VRL6-HP

K10-MS

10

VRL9

VRL9

K11-MD

10

VRL8

VRL8

K10-MS

15

VRL8

VRL8

K11-MD

15

VRL6

VRL8

K10-MS

20

VRL6

VRL8

K11-MD

20

VRL6

VRL6-HP

K10-MS

25

VRL6

K11-MD

25

VRL6-HP

K11-MS

10

VRL9

VRL9

K12-MD

15

VRL8

VRL8

K11
MS
K11-MS

15

VRL9

VRL9

K12-MD
K12 MD

20

VRL6

VRL6

K11-MS

20

VRL6

VRL8

K12-MD

25

VRL6-HP

K11-MS

25

VRL6

VRL8

K04-TD

VRL6

VRL6

K12-MS

15

VRL9

VRL9

K04-TD

VRL6

VRL6

K12-MS

20

VRL9

VRL9

K05-TD

VRL6

VRL6

K12-MS

25

VRL8

VRL8

K05-TD

VRL6

VRL6

K05-TS

ALL

VRL8

VRL8

K05-TD

5 1/2

VRL6

VRL6

K06-TS

5 1/2

VRL9

VRL9

K06-TD

5 1/2

VRL6

VRL8

K06-TS

7 1/2

VRL8

VRL8

K06-TD

7 1/2

VRL6

VRL6

K06-TS

10

VRL6

VRL8

K06-TD

10

VRL6

VRL6

K07-TS

7 1/2

VRL9

VRL9

K07-TD

7 1/2

VRL8

VRL8

K07-TS

10

VRL9

VRL9

K07-TD

10

VRL6

VRL6

K07-TS

15

VRL8

VRL8

K07-TD

15

VRL6

VRL6

K08-TS

7 1/2

N.A

N.A.

K08-TD

7 1/2

VRL8

VRL8

K08-TS

10

VRL9

(2) VRL9

K08-TD

10

VRL8

VRL8

K08-TS

15

VRL9

VRL9

K08-TD

15

VRL6

VRL6

K09-TS

15

(2) VRL9

(2) VRL9

K09-TD

20

VRL6

VRL8

K09-TS

20

VRL9

VRL9

K09-TD

25

VRL6

VRL6

K09-TS

25

VRL8

VRL9

K10-TD

15

VRL9

VRL9

K10-TS

15

(2) VRL9

(2) VRL9

K10-TD

20

VRL8

VRL8

K10-TS

20

(2) VRL9

(2) VRL9

K10-TD

25

VRL6

VRL8

K10-TS

25

VRL9

VRL9

K11-TD

20

VRL9

VRL9

K11-TS

25

(2) VRL9

(2) VRL9

K11-TD

25

VRL8

VRL8

K11-TS

30

(2) VRL9

(2) VRL9

K12-TD

25

VRL9

VRL9

K12-TS

30

(3) VRL9

(3) VRL9

K12-TD

30

VRL8

VRL8

Model

Valve selections are based on 60 Hz operation and refer to air having a density equal to 0.075 lbs / cu. Ft and inlet temperature of 68 deg F. Data is subject to
g without notice.
change

76

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

Safety Valves
SN 1733-4 1/1

The VRL valves are designed to protect blowers and / or motors


from over pressurization or excess vacuum. When there is over
pressurization, the valve opens and discharges to the outside.
When there is excess in vacuum, the valve opens and takes flow
from outside.
The valves have been designed for low pressure / low vacuum,
with minimal difference between the initial value at which the
valve begins to open and its fully-opened position. The valves are
supplied with 2 different springs to maximize its efficiency.
These compact valves, made of aluminum alloy, are both easy to
install and calibrate. The valves are designed to operate in a wide
range of capacities. The VRL can be plumbed to divert excess
primary flow through a secondary external outlet when working in
pressure conditions or to pipe-in a secondary flow when working
in vacuum.
Maximum efficiency is achieved by keeping operating values
(flow versus pressure or vacuum) within the operating range
(shaded area on graph). Capacity refers to air having a density
equal to 0.075 lbs./cu.ft .
Psig

In Hg

VRL6

VRL8

VRL9

OPERATING RANGE

In WG
270

18

240

16

14

12

10

90

60

30

Pressure / Vacuum

210
180

VRL6

150

VRL8

VRL9

120

200

400

600

800

1000

1200

1400

1600

1800

2000

2200

Capacity
H

OVERALL DIMENSIONS

TYPE

ND

WEIGHT (Lbs)

VRL6

2 NPT

4.02

6.90

0.47

1.9

VRL8

3 NPT

5.31

7.48

0.59

4.2

VRL9

4 NPT

6.30

8.11

0.71

5.7

H
D

Dimensions in inches.

Specifications subject to change without prior notice.

Scfm

FPZ, Inc

77

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

High Pressure Safety Valves

The VRL H.P. valves are designed to protect blowers and / or motors from
over pressurization or excess vacuum. When there is over pressurization, the
valve opens and discharges to the outside. When there is excess in vacuum,
the valve opens and takes flow from outside.
The valve have been designed for low pressure / low vacuum, with minimal
difference between the initial value at which the valve begins to open and its
fully-opened position.
These compact valves, made of aluminum alloy, are both easy to install and
calibrate. The valves are designed to operate in a wide range of capacities.
The VRL H.P. can be plumbed to divert excess primary flow through a
secondary external outlet when working in pressure conditions or to pipe-in a
secondary flow when working in vacuum.
Maximum efficiency is achieved by keeping operating values (flow versus
pressure or vacuum) within the operating range (shaded area on graph).
Capacity refers to air having a density equal to 0.075 lbs./cu.ft .

Psig

VRL6 - H.P.

VRL8 - H.P.

OPERATING RANGE

In Hg In WG
320

11.5
23

Pressure / Vacuum

11
22

300

10.5
21
10
9.5

280
20
19

VRL6 - H.P.

VRL8 - H.P.

260

9
18
8.5

240

17

220
0

200

400

600

800

1000

1200

1400

1600

Capacity
H

OVERALL DIMENSIONS
TYPE

ND

WEIGHT (Lbs)

VRL6 - H.P.

2 NPT

3.94

6.57

0.47

2.1

VRL8 - H.P.

3 NPT

5.31

7.48

0.59

4.2

H
D
A

Dimensions in inches.

Specifications subject to change without prior notice.

1800 scfm

78

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

Inline Filters
SS1110

FPZ inline filters are typically used in vacuum applications to prevent debris from entering the blower. Inline filters
consist of a metal housing with a metal cover retained by quick - change clamps for easy servicing of the element.
Polyester elements are recommended for humid applications.

CSL Series

CT Series

Dimension tolerance +

1/8

Service area needed

FEATURES & SPECIFICATIONS

OPTIONS (Inquiries Encouraged)


Vacuum regulator & gauge available
Various media available
Epoxy coated housings
Special connections
Available in Stainless Steel
Activated carbon prefilter to reduce odor
Alternate Top-to-canister fastening system
for low pressure or pulsating systems
Dome hood for high holding capacity

Polyester: 99%+ removal efficiency standard to 5 micron


Paper: 99%+ removal efficiency standard to 2 micron
Stainless steel torsion clips for durability
Rugged all steel construction with Baked enamel finish
Low pressure drop
Positive sealing O-ring seal system
Large dirt holding capacity and easy field cleaning,
especially when mounted horizontally or inverted
Fully-drawn one piece canister
Filter change out differential: 10-15 H2O Over Initial Delta P
DIMENSIONS
(Inches)
Polyester
Element

Paper
Element

NPT

CSL-843-050HC

CSL-842-050HC

4 /8

CSL-843-075HC

CSL-842-075HC

4 /8

CSL-843-100HC

CSL-842-100HC

CSL-843-125HC

CSL-842-125HC

4 /8

Used on Models

Approx
Wt. Lbs

/16

10DL

/16

15DH

06

K03-MS, 20DH

13

K04-MS, K04-TD, 30DH, 40DH

/16

5 /8

/16

5 /8

4 /8

5 /8

5 /8

CSL-849-150HC

CSL-848-150HC

7 /16

CSL-851-200HC

CSL-850-200HC

10

7 /8

K05-MS, K06-MS, K05-TD, K06-TD,


K07R-MD, K08R-MD

15

CT-235P-300C

CT-234P-300

3"

18

13

9 /8"

13 1/2"

16 /5"

13 /8"

10"

14"

K05-TS, K06-TS, K07-MS, K08-MS,


K07-TD, K08-TD

30

CT-235P-400C

CT-234P-400C

4"

18

13

9 /8"

13 1/2"

16 /5"

13 1/8"

10"

14"

K09-MS, K10-MS, K09-MD, K10-MD,


K11-MD, K12-MD, K09-TD, K10-TD

29

CSL-335P-400*

CSL-334P-400C*

4"

27 /8"

3"

14"

18 1/2"

3"

12"

15"

K07-TS, K08-TS, K11-MS, K12-MS,


K11-TD, K12-TD

30

CT-275P-500C

CT-274P-500C

18

16

19

14 /8

9 /8

14

20

K09-TS, K10-TS

50

CTD-375P-500C

CTD-374P-500C

25 /8

16

19

21 1/2"

17

14

35

K11-TS, K12-TS

60

* Male x male npt connections


Dimensions for reference only

/16"
/16"

/16 5

FPZ, Inc

79

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

Inlet Filters
SS1110

FPZ inlet filters are used for pressure applications. The inlet filters combine filtration and sound attenuation into a
compact package. Inlet filters consist of a filter cartridge enclosed by a carbon steel weather hood. Elements are
easily serviceable by simply removing the weather hood.

Noise attenuation may vary due to application


Dimension tolerance + 1/8

FEATURES & SPECIFICATIONS


Polyester: 99%+ removal efficiency standard to 5 micron
Paper: 99%+ removal efficiency standard to 2 micron (15
micron for FL10)
Fully drawn weatherhood - no welds to rust or vibrate apart
Tubular silencing design - tube is positioned to maximize
attenuation and air flow while minimizing pressure drop
Durable carbon steel construction with baked enamel finish
and powder coated weatherhood
Interchangeable elements: Polyester, Paper
Low pressure drop center bracket and outlet pipe design
Filter change out differential: 10-15 H2O Over Initial Delta P

Dimensions
(Inches)
B

FS-14-075

FS-14-100

Polyester
Element

Paper Element

FS-15-050

FS-14-050

FS-15-075
FS-15-100
FS-19P-125

FS-18P-125

NPT

OPTIONS (Inquiries Encouraged)

Various media available


1/8 & 1/4 tap holes
Pressure Drop Indicator
Available in Stainless Steel
Epoxy coated housings
Hot dipped galvanized housings
Special connections, NPT

Used on Models

Approx
Wt. Lbs

10DL

15DH

O6

6 /8

1 /8

K03-MS, 20DH

FS-19P-150

FS-18P-150

6 /8

1 /8

K04-MS, K04-TD, 30DH, 40DH

FS-31P-200

FS-30P-200

10

K05-MS, K05-TD

FS-231P-200

FS-230P-200

12

10

K06-MS, K06-TD, K07R-MD, K08R-MD

14

FS-231P-300

FS-230P-300

3"

13

10

K07-MS, K05-TS, K07-TD

15

FS-235P-300

FS-234P-300

3"

13

16

K08-MS, K06-TS, K08-TD

29

FS-235P-400

FS-234P-400

4"

14

16

K09-MS, K10-MS, K09-MD, K10-MD,


K11-MD, K12-MD, K09-TD, K10-TD

30

FS-245P-400

FS-244P-400

4"

14

16

K07-TS, K08-TS, K11-MS, K12-MS, K11-TD,


K12TD

31

NA

FL10*

NA

14 3/8

1 3/8

16 3/16

K09-TS, K10-TS, K11-TS, K12-TS,

18

*Tubular silencers not included on FL10

80

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

Dirty Filter Indicator

FEATURES
Monitors Filter Continuously
Easy Filter Maintenance
Filter Element Life Maximized
Downtime Reduced
Graduated Restriction Readings
SPECIFICATIONS
The dirty filter indicator shows the amount of
filter element restriction and how much life the element
has left. This is a convenient and inexpensive solution
to receiving the maximum usage from every element.

Part No: VG-020-013

The yellow indicator in the filter monitor gauge drops


as the dirt accumulates on the filter element. The
element is ready for change out or servicing when the
yellow indicator reaches the red zone. This allows you
to determine the condition of the filter element even
after the equipment has been shut down.
The element should be serviced or replaced at the
maximum pressure drop of 10-15 inches of water.
If the blower is operating at its maximum rated pressure,
contact the factory for recommended setting.

GAUGE IN ACTION

Normal Clean
Filter

Gauge shows how


much capacity
remains

Gauge shows filter


element capacity
used. Filter
requires service

Note: The monitor gauge has a 1/8 MPT connection. It is


mounted either on the weatherhood or on the outlet pipe
depending on the filter assembly. Used for pressure
applications only.

ACCESSORIES 81

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

Flow Converting Devices


VS6 / VS8
SN 2616-1 1/1

This all aluminum device is simple in both design and operation. Change of flow direction is attained by an electronically or pneumatically activated
diverter.
3

cfm

m /h

800

1400

600

1000

500

VS8
VS

M
F

800

DN

400
600
500

300

VS 6

400

200

300
200
100
100

50

Pressure drop per side


(inlet/outlet)

B
A max

50

O execution

0
0

20

40

60

0,5

TYPE
VS 6
VS 8

DN
2
3

80

100

1,0

mbar
psig

1,5

A
(1)

15.43
(1)
19.09

120

B
4.13
4.02

(2)

16.42
(2)
20.08

C
4.29
5.28

F
M6
M6

H
4.33
6.3

I
2 x int.3.35
4 x int.4.72

L
3.94
5.91

SI 1787
SI 1788
SI 2021

Other execution

P
With piped outlet

Executions O/P
Executions Y/H/K with pneumatic
control
Executions Y/H/K with electrical
control

EXECUTION
O/P
Y/H/K

P-Y-H-K

Y
With double control

Electrical control
Thrust solenoid
Working ratio
Max. cycle duration
Max. activated time
Power rating
Standard supply voltages

(3)

H
With collector and double control

K
With double collector and double control

Available connection
-

60% of cycle time


5 min.
3 min.
56 W
120 W (3)
V: 24 DC110 AC220 AC

Only for VS6 (dp max. +350/-350 mbar)

Pneumatic control
Thrust air cylindrer
Max pressure
Air consumption
Operating temperature

TF threaded flange GAS (G 1 , G 2, G 3);


TF threaded flange NPT (NPT 1 , NPT 2, NPT 3);
See SU 0012.

Dimensions in inches. Tolerance on given values 10% - unbinding and can be changed without prior notice.

O
3.46
4.33

(2) Electronically activated


(3) Pneumatically activated

Overall dimensions refer to O execution without flanges


For the dimensions of the other executions pls see:

M
6.38
8.27

Double effect
10 Bar
0.02 litres/cycle
-5 C ~ +70 C

82

FPZ, Inc

150 N. Progress Dr.


Saukville , WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

VK / PK Flange Connectors
SN 2048-1

VK - FLANGE CONNECTOR FOR VRL VALVES


This VK flange accessory allows direct connection of the VRL relief valves to the cover of the SCL "K" model blowers;
either in pressure or vacuum.

SCL K

Note: VK flanges usable on K-MS and K-TS blowers in vacuum or pressure. K-MD useable in vacuum only.
G

S1

VK flange
H

VRL

S1
R

SCL K
VRL

VK flange

I
I

Fig. 1

Fig. 2

CK accessory

Dimensions in Inches

Model
VK 5
VK 6
VK 6A
VK 8
VK 9

DN
1 1/2
2
2
3
4

G
1 NPT
2 NPT
2 NPT
3 NPT
4 NPT

H
1.18
1.97
2.34
1.69
1.81

I
3.62
4.33
5.12
5.12
5.90

R
0.26
0.33
0.35
0.35
0.35

S
0.59
0.75
0.75
0.83
0.90

S1
0.39
0.39
0.43
0.43
0.43

Fig.

Parts List
SP 1552
SP 1553
SP 1611
SP 1554
SP 1555

1
2

PK - FLANGED TUBE CONNECTOR FOR SCL K


The PK accessory allows connection of the "K" Series blowers directly to the process line without use of the intake or outlet manifolds.

CHARACTERISTICS
Flange in aluminium alloy with tube stub connection.
Supplied as a kit for mounting (with gasket and screws with wrench), please see the respective Parts List in table.
D

D
S

SCL K

S1

S1

R
PK accessory
MF accessory

R
I

I
Fig. 2

Fig. 1

Fig. 2

Fig. 1
Model
PK 5
PK 6
PK 6A
PK 8
PK 9

DN
1 1/2
2
2
3
4

D
1.89
2.36
2.36
3.46
4.48

H
1.18
1.97
2.34
1.69
1.81

I
3.62
4.33
5.12
5.12
5.90

R
0.26
0.33
0.35
0.35
0.35

S
0.79
1.38
1.38
0.94
1.06

Dimensions in Inches

S1
0.39
0.39
0.43
0.43
0.43

Note: PK flanges usable on K-MS, K-TS, K-TD blowers in vacuum or pressure. K-MD useable in vacuum only.

Fig.
1
2

Parts List
SP 1543
SP 1544
SP 1609
SP 1545
SP 1546

FPZ, Inc

83

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

CA / CK Manifolds

CA MANIFOLD FOR FA/FL FILTERS


90 wide radius PVC manifold with flanged connection and unthreaded tube end. Working temperature -20 to +40C ( -5 +105 F).

B
D

Type

DN

CA4

1.25"

8.66

3.54

1.65

0.59

2.95

0.28

CA4V

1.25"

8.66

3.54

1.65

0.59

2.52

CA5

1.5"

10.24

4.33

1.89

0.59

3.35

CA5V

1.5"

10.24

4.33

1.89

0.59

2.95

CA6

2"

12.60

5.31

2.36

0.59

CA6V

2"

12.60

5.31

2.36

CA8

3"

14.96

7.28

3.46

Fig.

30

0.28

0.28

45O

0.28

3.35

0.28

45O

0.59

3.35

0.28

0.59

4.72

0.28

CA9

4"

15.75

9.25

4.45

0.79

5.91

0.35

CA10

5"

17.72

11.81

5.51

0.79

8.27

0.71

Dimensions in inches - unbinding and can be changed without prior notice.

R=2D

Fig. 1

R
Fig. 2

Fig. 3

CK MANIFOLD
90 aluminium manifold for K models supplied in a kit containing the gasket and bolts.
Fig. 1
I4

I1 I2

I1

I1

I2

I2
A

I3

I4

I3

I1 I2

E1

Fig. 2

A
90

22.5
Int.I

Int.I
G

B
22.5
90

22.5
90

D
22.5

90

Type

DN

E1

I1

I2

I3

I4

CK4

1.25"

2.72

3.33

2.20

1.15

0.27

0.45

0.27

M6

0.57

0.57

2.76

2.76

CK5

1.5"

3.15

3.94

2.20

1.69

0.27

0.45

0.27

M6

0.69

0.69

3.35

3.35

CK6

2"

3.62

4.65

2.72

2.16

0.31

0.51

0.35

M8

0.73

0.95

3.92

4.10

CK8

3"

5.71

5.71

4.31

2.95

0.39

0.35

M8

5.12

CK9

4"

6.50

6.50

5.22

3.54

0.39

0.35

M8

5.90

CK10

5"

8.66

8.66

7.56

5.04

0.39

0.35

M8

7.48

Dimensions in inches - unbinding and can be changed without prior notice.

Fig.
1

84

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

Gauges

ACCESSORIES

Gauges, Check Valves, Silencers, Enclosures


Gauges are important for monitoring the operating pressure or vacuum of
the blower. Gauges should be positioned as close to the blower as possible.

Part
number
VG25-60
VG25-200
VG25-300
PG25-60
PG25-200
PG25-300
PG20-15

1/4 NPT

Duty

Scale

Vacuum
Vacuum
Vacuum
Pressure
Pressure
Pressure
Pressure

0-60" H2O
0-200" H2O
0-300" H2O
0-60" H2O
0-200" H2O
0-300" H2O
0-15 psi

2.88

2.59

2.25

1.9

Dimensions in inches. Tolerance on given values 10% - unbinding and can be changed without prior notice.

Check Valves

Swing check valves allow air to flow in one direction. These valves prevent
backflow into the blower and are supplied in bronze or brass.

Part
Number
CV075
CV10
CV125
CV15
CV20
CV30
CV40

NPT

0.75"
1"
1.25"
1.5"
2"
3"
4"

2.4
2.8
3.2
3.6
4.3
5.8
6.9

1.9
2.2
2.5
3.1
4.2
5.5

2.7
3.2
3.5
4.2
6.1
7.1

Dimensions in inches. Tolerance on given values 10% - unbinding and can be changed without prior notice.

Silencers
A
E

Silencers provide additional sound attenuation.


TYPE
SS 4
SS 5
SS 6
SS 8
SS 9

C D

D
1 1/4
1 1/2
2
3
4

A
7.5
7.9
9.1
19.1
18.3

B
5.5
6.7
7.9
15.7
16.9

C
2.8
3.1
3.5
6.0
6.7

E
2
1.2
1.2
3.3
1.1

F
0.6
0.8
0.8
0.8
0.8

lbs
0.8
1.1
1.3
4.8
9.9

Steel manufactured (apart from SI 9 / SS 9 - entirely in aluminium) with


sound absorbing polyurethane element.
Dimensions in inches. Tolerance on given values 10% - unbinding and can be changed without prior notice.

Sound Enclosures
A

Part #
IH1
IH3
IH5
IH7
IH8
IH9
IH10
IH11
IH12
IH13

Used on models
SCL K03-MS
SCL K04-MS
SCL K05-6 MS + 30-40 DH

SCL K07-8 MS / MD
SCL K07-8 TD
SCL K07-8 TS
SCL K09-12 MS/MD
SCL K09-10 TD
SCL K11-TD
SCL K09-11 TS

A
13.4
14.3
16.9
31.7
31.7
31.7
31.7
31.7
31.7
31.7

B
18.2
19.7
26.8
64.4
64.4
64.4
67.2
67.2
67.2
67.2

C
15.8
16.5
21.3
26
26
26
30
30
30
31.5

Dimensions in inches - unbinding and can be changed without prior notice.

FPZ, Inc

85

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

ACCESSORIES

Flexible Sleeves / Flanges

FLEXIBLE SLEEVE
Steel reinforced rubber - coated fibreglass flex tubing, including 2
adjustable hose clamps. Working temperature: -55 +176 C (-67
+350 F). Maximum working pressure: 3 bar (44 psi).
TIPO
TYPE
MF 1
MF 2
MF 3
MF 4
MF 5
MF 6
MF 8
MF 9
MF 10

DN

1/2
3/4
1
1 1/4
1 1/2
2
3
4
5

20
26
32
45
50
64
89
114
140

200
200
200
200
250
250
330
330
330

THREADED FLANGE
Threaded flange in aluminum alloy.
R1

TIPO
TYPE
TF 3
TF 4
TF 4V
TF 5
TF 5V
TF 6
TF 8
TF 9

D
I2

I1

R2

S
H

I1

I2

R1

R2

G 1
G 1 1/4
G 1 1/4
G 1 1/2
G 1 1/2
G 2
G 3
G 4

18
18
18
18
18
18
25
25

55
75
64
85
75
85
-

120
150

6.5
6.5
6.5
6.5
6.5
6.5
-

6.5
9

10
10
10
10
10
10
13
13

SLEEVE
Aluminum alloy or steel flanged sleeve coupling.
D

S1

TIPO
TYPE
MP 1
MP 2
MP 3
MP 4
MP 4V
MP 5

Fig. 1
Mat.: Al

Fig. 2
Mat.: Al

DN

1/2
3/4
1
1 1/4
1 1/4
1 1/2

21
27
33
42
42
48

G 1/2
G 3/4
-

100
100
35
35
35
35

55
75
64
85

6.5
6.5
6.5
6.5

85
85
25
25
25
25

Fig. 3
Mat.: Fe
Fig.
3

TIPO
TYPE
MP 5V
MP 6
MP 8
MP 9
MP 10

DN

1 1/2
2
3
4
5

48
60
88
114
140

Dimensions in mm. Tolerance on given values 10% - unbinding and can be changed without prior notice.

Fig. 4
Mat.: Fe
G

35
35
45
4 npt 100
5 npt 60

S1

75
85
120
210

6.5
6.5
6.5
18

25
25
32
80
40

Fig.
1
2
3
4

86

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

TECHNICAL

Single Phase Electric Motors


SN 2102-2

SINGLE PHASE DUAL VOLTAGE


GENERAL SPECIFICATIONS:
1- Type:
Single phase AC MOTOR - IEC 60034
2- Marks:
cURus, CE
3- Poles:
2
4- Frequency:
60 Hz
5- Insulation Class:
F
6- Enclosure:
TEFC
7- Protection:
IP 55
8- Thermal Protector:
KLIXON 140 C
1.0
9- Service Factor:
10- Max. Ambient:
40C
11- Duty:
Cont.
12- Construction:
Aluminium frame
POWER

VOLTAGE

SPEED

FLA

Hp
1/3
1/2
3/4
1
1
2
3

V
115-208/230
115-208/230
115-208/230
115-208/230
115-208/230
115-208/230
115-208/230

min -1
3330
3360
3450
3450
3330
3440
3425

A
03.5 / 01.7
04.8 / 02.6
09.8 / 04.9
13.0 / 07.2
13.6 / 07.3
24.0 / 12.0
31.5 / 16.0

LOW VOLTAGE 115 V - 60 Hz

STARTING
CURRENT
A
012.3 / 06.0
016.8 / 09.1
046.1/ 23.0
049.4 / 24.7
054.4 / 29.2
079.2 / 39.6
154.4 / 78.4

POWER
CAPACITOR
FACTOR
cos
F
0.97
16.0 - 400 V
0.96
16.0 - 400 V
0.95
20.0 - 400 V
0.66
31.5 - 400 V
0.97
50.0 - 400 V
0.90
70.0 - 400 V
0.85
60.0 - 400 V

HIGH VOLTAGE 208-230 V - 60 Hz

THERMAL PROTECTION NORMALLY CLOSED

THERMAL CUT-OFF

Specifications subject to change without notice. Alternate motor suppliers may be used.

FPZ, Inc

87

150 N. Progress Drive


Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

TECHNICAL

Three Phase Electric Motors


SS 1209

THREE PHASE MOTOR


GENERAL SPECIFICATIONS:
1. Type: 3-phase AC Motor IEC 60034
2. Marks: cURus, CE
3. Poles: 2
4. Insulation class: F
5. Frequency: 60 hz / 50 hz
6. Enclosure: TEFC
POWER

7. Protection
O
8. Thermal protector: Klixon 150 C
9. Service factor: 1.15
10. Max. Ambient 40O C
11. Duty: Continuous
12. Construction: aluminum frame

60 HZ

50 HZ
CABLE
ENTRY
1***

CABLE
ENTRY
2

3.9

M16

M20

0.73

3.6

M16

M20

2.6 / 1.5

0.78

3.8

M16

M20

230/400

3.5 / 2.0

0.78

5.0

M20

M25

0.86

230/400

4.5 / 2.6

0.82

5.6

M20

M25

6.3 / 2.9

0.82

230/400

6.1 / 3.5

0.82

5.0

M20

M25

9.0 / 4.1

0.87

230/400

8.5 / 4.9

0.81

7.1

M20

M25

POWER
FACTOR VOLTAGE
cos

FLA
230 / 400
(200 V)

POWER STARTING
FACTOR CURRENT
RATIO*
cos

HP

KW

SIZE

VOLTAGE

FLA
208 / 460

0.33

0.25

63

208-230/460

1.5 / 0.7

0.75

230/400

1.4 / 0.8

0.70

0.5

0.37

63

208-230/460

2.3 / 1.0

0.79

230/400

2.1 / 1.2

0.75

0.55

71

208-230/460

2.7 / 1.2

0.85

230/400

0.75

80

208-230/460

3.3 / 1.5

0.84

1.5

1.1

80

208-230/460

5.0 / 2.3

1.5

90

208-230/460

2.2

90

208-230/460

3.0

5.5

90

208-230/460

11.2 / 5.9

0.80

230/400

11.8 / 6.8

0.80

7.0

M20

M25

100

208-230/460

12.9 / 6.1

0.85

230/400

11.6 / 6.7

0.85

6.0

M25

M20

4.0

100

208-230/460

17.5 / 8.1

0.88

230/400

14.0 / 8.1

0.88

6.2

M25

M20

7.5

5.5

112

208-230/460

20.0 / 9.5

0.86

230/400

19.4 / 11.2

0.85

7.6

M25

M20

10

7.5

112

208-230/460

26.0 / 12.5

0.88

230/400

25.6 / 14.8

0.87

8.2

M25

M25

15

11.0

132

208-230/460

40.0 / 21.7

0.84

230/400

37.5 / 21.7

0.84

6.9

M32

M32

20**

15.0

132**

208-230/460

54.0 / 26.0

0.86

200/400

(61.0) / 30.5

0.82

7.0

M32

M32

160

208-230/460

54.0 / 29.8

0.85

230/400

51.6 / 29.8

0.85

8.1

M40

M40

25

18.5

160

208-230/460

63.0 / 34.8

0.87

230/400

60.0 / 34.8

0.87

8.5

M40

M40

30

22.0

160

208-230/460

72.0 / 41.5

0.87

230/400

72.0 / 41.5

0.87

8.4

M40

M40

* FLA x starting current ratio = starting current


** 9 leads motor applicable to 20 hp motors with 132 frame (MS / MD series)
*** Cable entry 1 includes cable gland

WIRING DIAGRAM

WIRING DIAGRAM
MIN VOLTAGE

THERMAL PROTECTION
NORMALLY CLOSED
6 LEADS MOTORS.
208-230/460 V - 60 Hz
230/400 V - 50 Hz

Y MAX VOLTAGE

THERMAL CUT-OFF

YY MIN VOLTAGE

Y MAX VOLTAGE

U2

V2

W2

U2

V2

W2

U5

V5

W5

U5

V5

W5

U1

V1

W1

U1

V1

W1

THERMAL PROTECTION
NORMALLY CLOSED

THERMAL CUT-OFF

** 9 LEADS MOTOR. APPLICABLE TO 20Hp SIZE 132


208-230/460 V - 60 Hz
200/400 V - 50 Hz
.

Specifications subject to change without notice. Alternate motor suppliers may be used.

88

FPZ, Inc
150 N. Progress Drive
Saukville, WI, 53080 - U.S.A.
Tel. (262) 268-0180
Fax (262) 268-0415
E-mail usa@fpz.com

TECHNICAL

Airflow Through an Orifice


Pressure
Orifice Diameters - Inches

Pressure "
H2O

1/32

1/16

1/8

3/16

1/4

5/16

3/8

7/16

1/2

5/8

3/4

1-1/4

1-1/2

1-3/4

2.0

2-1/4

2-1/2

2-3/4

0.0

0.1

0.2

0.5

0.9

1.4

2.0

2.7

3.5

7.8

14

22

31

43

56

70

87

105

125

0.0

0.1

0.3

0.7

1.2

1.9

2.8

3.8

4.9

11

20

31

44

60

79

100

123

149

177

0.0

0.1

0.4

0.8

1.5

2.4

3.4

4.6

6.0

10

14

24

38

54

74

96

122

150

182

217

0.0

0.1

0.4

1.0

1.7

2.7

3.9

5.3

7.0

11

16

28

43

63

85

111

141

174

210

250

0.0

0.1

0.5

1.1

1.9

3.0

4.4

6.0

7.8

12

18

31

49

70

95

124

157

194

235

280

10

0.0

0.2

0.7

1.5

2.8

4.3

6.2

8.4

11.0

18

25

44

69

99

135

176

222

275

332

395

15

0.1

0.2

0.8

1.9

3.4

5.3

7.6

10.3

13.4

21

30

54

84

121

165

215

272

336

407

484

20

0.1

0.2

1.0

2.2

3.9

6.1

8.7

11.9

15.5

25

35

62

97

140

190

248

314

388

469

559

25

0.1

0.3

1.1

2.4

4.3

6.8

9.8

13.3

17.3

28

39

69

108

156

212

277

351

434

525

624

30

0.1

0.3

1.2

2.6

4.8

7.4

10.7

14.5

19.0

30

43

76

119

171

233

304

385

475

574

684

35

0.1

0.3

1.3

2.9

5.1

8.0

11.5

15.7

20.5

33

46

82

128

185

251

328

415

513

620

738

40

0.1

0.3

1.4

3.1

5.5

8.6

12.3

16.8

21.9

35

49

88

137

197

268

351

444

548

663

789

45

0.1

0.4

1.5

3.3

5.8

9.1

13.1

17.8

23.2

37

52

93

145

209

285

372

470

581

703

836

50

0.1

0.4

1.5

3.4

6.1

9.6

13.8

18.7

24.5

39

55

98

153

220

300

392

496

612

740

881

55

0.1

0.4

1.6

3.6

6.4

10.0

14.4

19.6

25.7

41

58

103

160

231

314

411

520

641

776

924

60

0.1

0.4

1.7

3.8

6.7

10.5

15.1

20.5

26.8

43

60

107

167

241

328

429

542

670

810

964

65

0.1

0.4

1.7

3.9

7.0

10.9

15.7

21.3

27.9

45

63

111

174

251

341

446

564

697

843

1003

70

0.1

0.5

1.8

4.1

7.2

11.3

16.3

22.1

28.9

46

65

116

181

260

354

463

585

723

874

1041

75

0.1

0.5

1.9

4.2

7.5

11.7

16.8

22.9

29.9

48

67

120

187

269

366

479

606

748

905

1077

80

0.1

0.5

1.9

4.3

7.7

12.1

17.4

23.6

30.9

50

70

124

193

278

378

494

625

772

934

1112

85

0.1

0.5

2.0

4.5

8.0

12.4

17.9

24.4

31.6

51

72

127

199

285

390

509

644

795

962

1145

90

0.1

0.5

2.0

4.6

8.2

12.8

18.4

25.1

32.7

53

74

131

204

294

401

524

663

818

990

1178

95

0.1

0.5

2.1

4.7

8.4

13.1

18.9

25.7

33.6

54

76

134

210

302

412

538

680

840

1016

1210

100

0.1

0.5

2.2

4.9

8.6

13.5

19.4

26.4

34.5

55

78

138

215

310

422

551

698

861

1042

1241

105

0.1

0.6

2.2

5.0

8.8

13.8

19.9

27.0

35.3

57

79

141

221

318

432

565

715

882

1068

1271

110

0.1

0.6

2.3

5.1

9.0

14.1

20.3

27.6

36.1

58

81

144

226

325

442

578

731

903

1092

1300

1 psi = 27.68" H2O

discharge coeffecient = 0.65

Air Temperature = 70 deg F

Airflow in CFM

Vacuum
Orifice Diameters - Inches
Vacuum "
Hg

1/32

1/16

1/8

3/16

1/4

5/16

3/8

7/16

1/2

5/8

3/4

1-1/4

1-1/2

1-3/4

2.0

2-1/4

2-1/2

2-3/4

0.5

0.0

0.1

0.6

1.3

2.2

3.5

5.1

6.9

14

20

36

56

81

110

144

182

225

272

324

0.0

0.2

0.8

1.8

3.1

4.9

7.1

9.6

13

20

28

50

79

113

154

202

255

315

381

453

0.1

0.3

1.1

2.5

4.4

6.8

9.8

13.0

17

27

39

70

109

157

214

280

354

437

529

629

0.1

0.3

1.3

3.0

5.2

8.2

11.8

16.0

21

33

47

84

131

189

257

336

425

525

635

756

0.1

0.4

1.5

3.3

5.9

9.3

13.4

18.0

24

37

53

95

148

214

291

380

481

594

718

855

0.1

0.4

1.6

3.7

6.5

10.0

14.6

20.0

26

41

58

104

162

234

318

416

526

650

786

936

0.1

0.4

1.7

3.9

7.0

11.0

15.7

21.0

28

44

63

111

174

251

341

446

564

696

842

1002

0.1

0.5

1.8

4.1

7.3

11.0

16.5

22.0

29

46

66

118

184

264

360

470

595

735

889

1058

0.1

0.5

1.9

4.3

7.7

12.0

17.3

23.0

31

48

69

123

192

276

376

491

621

766

927

1104

0.1

0.5

2.0

4.5

7.9

12.0

17.8

24.0

32

50

71

127

198

285

388

507

642

792

959

1141

10

0.1

0.5

2.0

4.6

8.1

13.0

18.3

25.0

33

51

73

130

203

293

398

520

659

813

984

1171

11

0.1

0.5

2.1

4.7

8.3

13.0

18.7

25.0

33

52

76

133

207

298

406

530

671

829

1003

1193

12

0.1

0.5

2.1

4.7

8.4

13.0

18.9

26.0

34

52

76

134

210

302

412

538

680

840

1016

1210

13

0.1

0.5

2.1

4.8

8.5

13.0

19.1

26.0

34

53

76

135

212

305

415

542

686

847

1025

1219

14

0.1

0.5

2.1

4.8

8.5

13.0

19.1

26.0

34

53

76

136

212

306

416

544

688

849

1028

1223

15

0.1

0.5

2.1

4.8

8.5

13.0

19.1

26.0

34

53

76

136

212

306

416

544

688

849

1028

1223

1" HG = 13.6" H2O

discharge coeffecient = 0.65

Air Temperature = 70 deg F

Airflow in CFM

Вам также может понравиться