Вы находитесь на странице: 1из 5

Tideflex Mixing System

Craan, Craanford, Gorey, Co. Wexford, Ireland for finished water storage facilities
Tel.: +353 (0) 53 942 8962Fax: +353 (0) 53 942 8963 Application Data Sheet (ADS)
www.measurIT.com email: info@measurIT.com Please complete any known details so that we can evaluate
your application and prepare a quotation. Thank you.

Reservoir/Tank Name:      


Project Location:      
     
Company:
Contact Name:      
Email:      
Address:      
City:       County:      
Phone:       Fax:      

Consulting Engineer:      


Contact Name:      
Email:      
Address:      
City:       County:      
Phone:       Fax:      

I. SYSTEM INFORMATION
INSTALLATION: SCADA: WATER SOURCE:
New Tank Tank on SCADA? Surface Water Reclaimed Water
Existing Tank yes no Ground Water      

OPERATION: MODE: PRIMARY DISINFECTION:


Distribution System Reservoir Fill-then-draw Chlorine UV Chlorine Dioxide
Clearwell Simultaneous Chloramine Ozone None
Combination fill and draw      

HIGH WATER LEVEL SHUTOFF: SECONDARY DISINFECTION:


by Altitude Valve None, floats on system Chlorine Chloramine None
by Pressure Switch       Chlorine Dioxide      

II. RESERVOIR / TANK DATA (Provide tank drawings if available. See nomenclature on page 4.)
TYPE OF RESERVOIR / TANK: Tank Manufacturer or Basis of Design:      
Circular Reservoir Irregular Shape At Grade Semi-Buried
Rectangular Reservoir Buried
Standpipe
Dry Riser Sphere/Spheroid Composite Hydropillar      
Elevated Tank
Wet Riser Wet Riser Diameter       m mm ft in

TANK DETAILS: (Provide tank drawings if available. See nomenclature on page 4.)
VOLUME:       m3 Megaliters MG gallons

1
Circular Reservoir / Standpipe Elevated Tank Rectangular Reservoir
m ft m ft m ft
Tank Diameter:       Bowl Diameter:       Length x Width       x      
Depth to Maximum Depth to Maximum
      Head Range:            
Operating Level Operating Level
Height From Foundation
     
Depth to Overflow       to Overflow Depth to Overflow      
Height from Foundation
     
to Max. Operating Level Number of Cells 1
Bottom Elevation:       Foundation Elevation:       Bottom Elevation:      

TANK MATERIAL: (select multiple if alternates for new tank)


Welded Steel Bolted Steel (conc. floor) Bolted Steel (steel floor) Riveted Steel
Prestressed Concrete Post-tensioned Concrete Cast-in-place Concrete
Composite (Elevated) Earthen Lined      

TYPE OF ROOF / COVER:


Fixed Roof Internal Roof Supports? yes no Floating Cover None, Open Reservoir

III. INLET / OUTLET PIPING (For new tanks that operate in fill-then-draw and for existing tanks that have a
common inlet/outlet pipe, complete the “Inlet” pipe data. The TMS separates inlet/outlet inside the tank)
Common Inlet/Outlet Pipe Separate Inlet and Outlet Pipes
Inlet Diameter       mm in Material: Penetration: bottom sidewall top
Outlet Diameter       mm in Material: Penetration: bottom sidewall
Outlet have Silt Stop? yes fixed pipe extension removable
no
Does tank have a dedicated drain pipe? yes no

IV. HYDRAULIC DATA


Minimum Fill Rate:      
gpm lps       Pumped Gravity
Maximum Fill Rate:      
Maximum Draw Rate:
peak demand + fire flow (if applicable)       gpm lps       Pumped Gravity

V. TANK FLUCTUATION / TURNOVER DATA (With one of the methods below, provide data on the typical, or
expected, daily fluctuation of tank levels in summer and winter, if different. *See nomenclature, page 4)
Method 1 Method 2 Method 3
Max. Operating Level* Min. Operating Level* % (percent) Volume Exchange
Summer       m       m             liters/day
Winter       ft       ft             gallons/day

Year Tank Constructed:      


Date of Last Inspection:       VI. REFROFIT INFORMATION
Date of Last Rehab/Repaint:       VII. WATER QUALITY ISSUES
Next Scheduled Rehab:      
Internal Baffles? yes no
Identify Water Quality Issues
Ice Formation? Identify known/suspected yescauses:no
Loss of Residual
Poor MixingRange
Water Temperature       min
DBPs > TTHM HAA5
Short-Circuiting
o
C o
F       max
Coliform Bacteria
Poor Turnover / Tank Fluctuation
Size of Largest Roof Hatch       dia sq. Nitrification
Long Detention Time
Elevated HPC
Thermal
Size of Largest Stratification
Shell Hatch       dia sq.
Biofilms
High Levels of Organics
Rechlorination/Recirculation
Taste & Odor
     
Sytems Installed? yes no Increased pH
Are Sampling taps installed? yes no Color
Samples been taken at different Turbidity
locations/depths inside the tank? yes no      
Has a tracer study, CFD, or 2
scale model been done? yes no
VIII. OVERFLOW PIPE PROTECTION
Check method used to prevent birds, rodents, cold drafts, etc. from entering tank thru overflow pipes

Overflow Pipe Size:       mm in


Tideflex Valve Overflow Security Valve (OSV) Screen Flap Valve

3
IX. COMMENTS
     

PLEASE MAIL, FAX OR E-MAIL COPIES OF TANK DRAWINGS, INSPECTION REPORTS/PHOTOS TO:
measurIT technologies
phone: +353 (0)53 942 8962 fax: +353 (0)53 942 8963 email: info@measurIT.com

4
X. TANK NOMENCLATURE