Академический Документы
Профессиональный Документы
Культура Документы
AT | UT | USS
Advanced Technology (AT) Series
The Industrys Smartest Induced Draft, Counterflow Cooling Towers
i
*Mark owned by the Cooling Technology Institute
We guarantee performance.
Every EVAPCO solution is put through rigorous research and
testing to deliver maximum efficiency and reliability. But we dont
stop there. We also lead the industry in independent, third-party
performance certifications. These certifications guarantee our
performance metricsso that you can plan your projects with
complete peace of mind.
We protect the environment.
Innovation and environmental sustainability go hand-in-hand at
EVAPCO. From sound reduction to water conservation to chemical
elimination, we are constantly developing new technologies that
deliver the ultimate operating advantages for our clients
and protect the planet for every generation that comes after us.
Crafted from decades of engineering know-how, the Advanced Technology (AT) cooling tower series from EVAPCO
features state-of-the-art induced draft, counterflow technology to deliver superior operating advantages in any climate.
From performance to maintenance, they simply work smarter.
Available in 60 cross sections and a capacity range of 33 to 5,141 nominal tons (144 to 22,596 kW).
See page 23 for model-by-model dimensions.
AT The original compact, low-horsepower, induced draft, axial fan solution for all
outdoor applications.
UT All of the benefits of the AT design, built with EVAPCOs Super-Low-Sound Fan
for sound-sensitive applications. See page 18 to learn more.
USS All-stainless-steel AT construction for maximum corrosion resistance, ideal for
coastal and other corrosive environments. See page 18 to learn more.
Hot Saturated Discharge Air
Principle of Operation
Warm water from the heat source is pumped to the water distribution
system at the top of the tower. The water is distributed over the wet deck
fill by means of large opening EvapJet nozzles. Simultaneously, air is
drawn in through the air inlet louvers at the base of the tower and travels
upward through the wet deck fill opposite the water flow. A small portion of the water is evaporated which removes the heat from the remaining water. The warm moist air is drawn to the top of the cooling tower by
the fan and discharged to the atmosphere. The cooled water drains to
the basin at the bottom of the tower and is returned to the heat source.
Drift
Eliminators
Hot
Water
In
Cool
ool
Dry
Dry
Entering
erin
ng
Air
Air
Cooled
o
Water
Out
Table of Contents
The Advanced Technology Tower at a Glance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Series Design Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
POWER-BAND Belt Drive System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Easy Maintenance Basin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Optional Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ultra-QuieT (UT) Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Ultra Stainless Steel (USS) Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Additional Resources: Specifying Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
EVAPCO Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Engineering Data & Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
22
EvapJet nozzle
***
With EVAPCO, you get a partner you can count on to keep you at the cutting edge of your field. Thats because we build
innovation into every HVAC solution that we deliver to you. Here are just some of the game-changing features youll find
in the Advanced Technology cooling tower series.
Sunlight
Air Intake
Debris
Splashout
At the heart of every Advanced Technology series cooling tower is EVAPCOs POWER-BAND Belt Drive System. Tough
enough to handle the most heavy-duty cooling tower applications, its also the easiest drive system to maintain in the industry.
Fan Motors
Belt Drive
Rated for a minimum L10 life of 75,000 hours, POWERBANDs fan shaft bearings are the cooling tower industrys most heavy-duty pillow-block bearings. That means
longer operating life and less risk of costly downtime.
All POWER-BAND belt drives and optional gear drives come with EVAPCOs unique 5-year
motor and drive warranty. The comprehensive plan covers fans, fan shaft, belts, sheaves, fan
bearings, gear box, flexible coupling, driveshaft, and motors to give you total protection.
With POWER-BAND, all periodic maintenance can be safely performed from the side of your Advanced Technology series
cooling tower. No standing inside the cold water basinand no need for fan deck handrails or safety cages.
The cold water basin is the most important area of a cooling tower to maintain. Dirt and debris naturally collect there
as a result of the evaporation process and must be cleaned out on a regular basis. The basin section of every Advanced
Technology series cooling tower is designed to allow quick and easy accesspromoting routine maintenance of the
cold water basin.
Easy Access
For most cooling towers, the strainer is subject to excessive wear and corrosion. Not so with EVAPCOs cooling
towers. Our strainers are constructed with stainless steel
a long-standing EVAPCO standardensuring that yours
will last the life of your cooling tower.
9
The Advanced Technology series also features a completely sloped basin from the upper to lower pan section.
This clean pan design allows the water to be completely
drained from the basin. The cooling tower water will drain
from the upper section to the depressed lower pan section where the dirt and debris can be easily flushed out
through the drain. This design helps prevent buildup of
sedimentary deposits and biological films, and minimizes
standing water. Note: On 4-foot-wide units, the pan is
sloped without the step.
Optional Equipment
The standard design of the EVAPCO Advanced Technology series makes it the easiest cooling tower to maintain in the
industry. Take your tower to the next level with a host of options that can make maintenance even easier and extend the
life of your cooling tower even longer.
Make it easy to service the fan motor and water distribution system with this
heavy-duty, self-supporting working platform and standard ladder. A less
expensive alternative to field erected catwalks, the system is OSHA compliant and ships in sections for easy installation. Note: The working platform is not
available on 4-foot-wide models.
Plus! Eliminate crane rentals with an optional davit that facilitates the easy
removal of motors, gear drives, and fans. The davit is constructed of aluminum
and is mounted on the side of the unit with a galvanized steel bracket. Note:
Davit ships loose and is installed in the field.
The basin provides the structural support for the unit and is the most
important part of you cooling tower. Maximize its protection against
corrosion with EVAPCOs optional stainless steel water touch basin,
which uses type 304 or type 316 stainless steel for the entire basin area,
including the support columns and plenum of the cooling tower and
the louver frames.
10
-40F
kW
14-64 to14-94
14-66 to 14-96
14-69 to 14-99
14-612 to 14-912
2
3
4
5
3
4
5
7
4
5
7
9
19-56 to 19-96
19-28 to 19-98
19-59 to 19-99
19-111 to 19-911
19-412 to 19-912
19-114 to 19-914
5
6
7
8
(2) 4
(2) 5
7
8
10
12
(2) 7
(2) 7
9
12
15
15
(2) 9
(2) 10
110-112 to 110-912
110-118 to 110-918
(2) 5
(2) 7
(2) 8
(2) 12
(2) 10
(2) 15
112-012 to 112-912
112-314 to 112-914
112-018 to 112-918
112-520 to 112-920
(2) 6
(2) 7
(2) 9
(2) 10
(2) 9
(2) 10
(2) 15
(2) 15
(2) 12
(2) 15
(2) 18
(3) 15
114-0124 to114-1324
114-526 to 114-926
(2) 16
(2) 16
(3) 16
(3) 16
(3) 20
(3) 20
26-517 to 26-917
(2) 5
(2) 7
(2) 9
28-217 to 28-917
(2) 6
(2) 8
(2) 12
29-318 to 29-918
29-121 to 29-921
29-024 to 29-924
29-228 to 29-928
(2) 6
(2) 7
(4) 4
(4) 5
(2) 9
(2) 12
(4) 7
(4) 7
(2) 12
(2) 15
(4) 9
(4) 10
210-124 to 210-924
210-136 to 210-936
(4) 5
(4) 7
(4) 8
(4) 12
(4) 10
(4) 15
212-59 to 212-99
212-024 to 212-924
212-128 to 212-928
212-036 to 212-936
212-0140 to 212-1640
(2) 5
(4) 6
(4) 7
(4) 9
(4) 10
(2) 7
(4) 9
(4) 10
(4) 15
(4) 15
(2) 9
(4) 12
(4) 15
(4) 18
(4) 20
214-0148 to 214-1248
214-552 to 214-952
(4) 16
(4) 16
**
**
**
**
215-29 to 215-99
(2) 6
(2) 8
(2) 12
217-59 to 217-99
217-111 to 217-911
217-412 to 217-912
217-214 to 217-914
(2) 7
(2) 8
(4) 4
(4) 5
(2) 10
(2) 12
(4) 7
(4) 7
(2) 15
(2) 15
(4) 9
(4) 10
220-112 to 220-912
220-118 to 220-918
(4) 5
(4) 7
(4) 8
(4) 12
(4) 10
(4) 15
224-018 to 224-918
224-720 to 224-920
(4) 9
(4) 10
(4) 15
(4) 15
(4) 18
(4) 20
228-0124 to 228-1024
228-526 to 228-926
(4) 16
(4) 16
**
**
**
**
Note: Heater control packages that include contactor, transformer or disconnects are also available;
speak to your local EVAPCO representative to learn
more about these options.
AT/UT/USS Heater Sizes *
3-CELL
0F
kW
4-CELL
2-CELL
1-CELL
Model No.
Model No.
0F
kW
-20F
kW
-40F
kW
39-336 to 39-936
39-242 to 39-942
(6) 4
(6) 5
(6) 7
(6) 7
(6) 9
(6) 10
310-136 to 310-936
310-154 to 310-954
(6) 5
(6) 7
(6) 8
(6) 12
(6) 10
(6) 15
312-036 to 312-936
312-042 to 312-942
312-054 to 312-954
312-260 to 312-960
(6) 6
(6) 7
(6) 9
(6) 10
(6) 9
(6) 10
(6) 15
(6) 15
(6) 12
(6) 15
(6) 18
(9) 15
314-0172 to 314-1272
314-578 to 314-978
342-526 to 342-926
(6) 16
(6) 16
(6) 16
**
**
**
**
**
**
420-124 to 420-924
420-136 to 420-936
(4) 10
(4) 15
(4) 15
(4) 15
(4) 20
(4) 20
424-024 to 424-924
424-028 to 424-928
424-036 to 424-936
424-0140 to 424-1640
(4) 12
(4) 15
(4) 18
(4) 20
(4) 18
(4) 20
(6) 18
(6) 20
(6) 15
(6) 18
(8) 18
(8) 20
428-0148 to 428-1348
428-552 to 428-952
456-526 to 456-926
(8) 16
(8) 16
(8) 16
**
**
**
**
**
**
** Consult factory
Optional Equipment
Electronic Water Level Control (EWLC)
Flanged Connections
12
13
EVAPCO Counductivity
Controller (ECC)
Bio-Control
Feeder (BCF)
CRF or MRF
Feeder
Inhibitor Operation
1. Polymer coated inhibitor tablet
2. Recirculated water permeates the polymer coating
3. Solid chemistry becomes a slurry inside the tablet
4. Osmotic pressure causes the tablet to swell, forcing the chemistry out through the polymer coating
5. Polymer coating controls the treatment release rate
6. Treated water returns to the basin
14
15
14-64 to14-94
14-66 to 14-96
14-69 to 14-99
14-612 to 14-912
0
0
0
0
0
0
0
0
19-56 to 19-96
19-28 to 19-98
19-59 to 19-99
19-111 to 19-911
19-412 to 19-912
19-114 to 19-914
4
4
4
4
4
4
0
0
0
0
0
0
110-112 to 110-912
110-118 to 110-918
0
0
0
0
112-012 to 112-912
112-314 to 112-914
112-018 to 112-918
112-520 to 112-920
0
0
7
7
0
0
225
225
114-0124 to114-1324
114-526 to 114-926
5
7
450
450
26-517 to 26-917
28-217 to 28-917
29-318 to 29-918
29-121 to 29-921
29-024 to 29-924
29-228 to 29-928
4
4
4
4
0
0
0
0
210-124 to 210-924
210-136 to 210-936
0
0
0
0
212-59 to 212-99
212-024 to 212-924
212-128 to 212-928
212-036 to 212-936
212-0140 to 212-1640
4
0
0
7
7
0
0
0
450
450
214-0148 to 214-1248
214-552 to 214-952
5
7
900
900
2-CELL
Operating
Weight Addition
for Low Sound
Fan (lbs.)
3-CELL
Model No.
Height
Addition for
Low Sound Fan
(in.)
4-CELL
2-CELL
1-CELL
Height
Addition for
Low Sound Fan
(in.)
Operating
Weight Addition
for Low Sound
Fan (lbs.)
215-29 to 215-99
217-59 to 217-99
217-111 to 217-911
217-412 to 217-912
217-214 to 217-914
4
4
4
4
0
0
0
0
220-112 to 220-912
220-118 to 220-918
0
0
0
0
224-018 to 224-918
224-720 to 224-920
7
7
450
450
228-0124 to 228-1024
228-526 to 228-926
5
7
900
900
39-336 to 39-936
39-242 to 39-942
4
4
0
0
310-136 to 310-936
310-154 to 310-954
0
0
0
0
312-036 to 312-936
312-042 to 312-942
312-054 to 312-954
312-260 to 312-960
0
0
7
7
0
0
675
675
314-0172 to 314-1272
314-578 to 314-978
342-526 to 342-926
5
7
7
1,350
1,350
1,350
420-124 to 420-924
420-136 to 420-936
0
0
0
0
424-024 to 424-924
424-028 to 424-928
424-036 to 424-936
424-0140 to 424-1640
0
0
7
7
0
0
900
900
428-0148 to 428-1348
428-552 to 428-952
456-526 to 456-926
5
7
7
1,800
1,800
1,800
16
Blade Passing
Frequencies
Frequency (Hz)
17
Premium Components
Type 316 Stainless Steel
Cold water basin
Vertical support columns
Air inlet louver frames
Plenum
PVC
EVAPAK fill
Water distribution system
Patented air inlet louvers
Patented drift eliminators
*Complete 316 stainless steel construction available for a minimal cost upgrade
18
Additional Resources:
Understanding & Specifying Sound
Sound
Sound is the alteration in pressure, stress, particle displacement and particle velocity, which is propagated in an elastic
material. Audible sound is the sensation produced at the ear
by very small pressure fluctuations in the air.
Sound Pressure
Sound pressure is the intensity of sound. Sound pressure (Lp)
in decibels is the ratio of measured pressure (P) in the air to a
reference sound pressure, PO=2 x 105 Pascal based on the
following formula:
L p (dB) = 10 log10 ( P2/ PO2)
25
Ft. Candles
SOUND PRESSURE
25
Ft. Candles
100W
50
Ft. Candles 100
Ft. Candles
100 ft.
50 ft.
25 ft.
25 ft.
SOUND PRESSURE
19
50 ft.
100 ft.
SOUND POWER
7 dB(A)
73
dB((A))
50
76 dB(
dB(A)
(A))
73 dB(A)
dB((A)
dB(A
dB(
A)
Sound Power
Sound power is the energy of sound. Sound power (Lw) in
decibels is the ratio of the calculated sound power, (W) to
a reference power, Wo=1 picowatt, according to the
following formula:
L W (dB) = 10 log10 (W/WO)
f=8000
dB(A) =10 log 10
50 ft.
10 ((dB+Cf) /10)
f=63
100 ft.
Band
Center
Frequency (Hz)
Frequency
Range (Hz)
Sample
(Hz)
Cf
(dB)
Zf
63
44-88
68
-26.2
4.18
125
89-175
76
-16.1
5.99
250
176-350
77
-8.6
6.84
500
351-700
73
-3.2
6.98
1000
701-1400
70
7.00
2000
1401-2800
68
+1.2
6.92
4000
2801-5600
71
+1.0
7.20
8000
5601-11200
73
-1.1
7.19
45
Fe
et
50
Existing
Cooling
Tower
Fe
et
50
et
Fe
Microphone Location
Microphone
50
Rooftop
Air
Handler
et
Fe
Measurement Location
Per Cooling Technology Institute Standard ATC-128
New
Cooling
Tower
50
Specifying Sound
Specify sound pressure in dB(A) measured 5 feet above
the fan discharge during full speed operation.
All manufacturers can meet a performance specification
with low sound options
Fan noise is what matters. 5 feet above the fan is where
it matters.
Road
Traffic
Easy Verification
At 5 feet from the cooling tower, a sound meter records
only cooling tower noise. You can easily verify the actual
noise coming from the cooling tower against the specified
sound data with good certainty.
If sound were specified at 50 feet or some greater distance
from the sound-sensitive location, there is increased uncertainty in the measured data due to other possible sound
sources within the 50 foot radius of the sound microphone.
Sound Quality
Sound coming from the top of the cooling tower is comprised of low- and mid-frequency fan noise. Low- and
mid-frequency fan rumble is very difficult to attenuate. Fan
rumble travels through everything and around everything
and is what is audible at any sound-sensitive location.
Sound coming from the sides of the cooling tower is
comprised of high-frequency water noise, is much less
objectionable than fan noise, and attenuates naturally with
distance.
Low-Mid Frequencies
Travel through and
around Obstructions
Fan Noise
Acoustical
Shadow
Water
Noise
High-Frequency
Self Attenuating
20
EVAPCO Representatives
Your EVAPCO representative is the local expert you can count on to help you with all your commercial HVAC needs
from getting quotes to answering questions to helping you manage your projects and orders. Simply contact him or her
whenever you need help; well get the job done. To find your local representative, visit evapco.com now.
evapSelect
evapSelect is a computer selection program that makes it easy for you to find and optimize the right EVAPCO solutions for every project. Evaluate thermal performance, space, and energy requirements across units; analyze optional
equipment features; and generate complete specifications and unit drawingsall within a friendly and familiar Windows
format. Contact your EVAPCO representative to access evapSelect now.
evapco.com
Bookmark evapco.com for the latest and most complete product information. The website contains a multitude of information and resources including:
Unit certified drawings (.pdf format)
Rigging instructions
Operation and maintenance instructions
Steel support drawings (.pdf format)
Scaled isometric views of towers in CAD (.dwg format)
Videos
Logo apparel and merchandise
3-D models of towers in Revit (.rfa format)
Product catalogs
21
AT | UT | USS
Nomenclature
AT-215-89L
(2) ACCESS DO
Product
Type
# of
Unit
Capacity
(3) 14 BFW/GVD INLET
Cells Width Indicator
Other
Unit
Length
Product Type
173-1/2 154-1/2
AT Indicates an Advanced Technology (AT)
tower 135-1/2
UT An AT tower with a super low sound fan
USS - An AT tower with stainless steel construction, 304, 316 or a combination. A USS tower may also
include a Super Low Sound Fan.
# of Cells
Determined by the number of inlet connections, can be 1, 2, 3, or 4
83-5/8
143
256
Unit Width
315-3/8
The total width of the unit in feet, all cells included. The value is rounded up to the next whole number.
428-3/8
487-3/4
Capacity Indicator
Relative performance indicator for example, an AT-215-89 has more capacity than an AT-215-49.
42' 8"
7
Unit Length
The total length of the unit in feet, all cells included. The value is rounded up to the next whole number.
Other
Some, but not all units endTwith a letter.
S Indicates a non-cataloged design.
L, U, M or E Indicates an alternateHmotor HP.
(2) ACCESS
DOOR
(2) ACCESS
DOOR
(2) ACCESS
DOOR
123-3/8
26
17-3/8
4
25' 8-7/8"
1- 3/8
157-1/4
161-1/2
162-1/2
167-1/4
5-1/8
42' 8"
22
ACCESS DOOR
53-3/4"
ACCESS
DOOR
4 MPT INLET
24-1/8"
2 MPT OVERFLOW
P
1 MPT MAKE-UP
37-1/2"
4 MPT OUTLET
19-3/4"
13"
3"
5-1/8"
5-7/8"
2 MPT DRAIN
4-3/8"
1"
24-1/4"
38-1/4"
12-3/4"
4' 1/2"
Weights (LBS)
Model No.
Nominal
Tonnage
Shipping
Operating
AT-14-64
AT-14-74
AT-14-84
AT-14-94
AT-14-66
AT-14-76
AT-14-86
AT-14-96
33
37
39
43
57
64
67
74
1,080
1,160
1,130
1,210
1,390
1,490
1,410
1,510
1,760
1,840
1,810
1,890
2,460
2,560
2,480
2,580
NOTE:
(1)
(2)
(3)
(4)
730
810
780
860
950
1,050
970
1,070
Dimensions
Fan
Motor
(HP)
Air Flow
(CFM)
2
2
3
3
3
3
5
5
9,600
9,500
10,900
10,700
15,300
15,100
18,000
17,700
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
6 5
7 5
6 5
7 5
6 5
7 5
6 5
7 5
6 3
7 3
6 3
7 3
6 3
7 3
6 3
7 3
3 11-7/8
3 11-7/8
3 11-7/8
3 11-7/8
5 11-7/8
5 11-7/8
5 11-7/8
5 11-7/8
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
23
Heaviest
SectionF
*14-69 to 14-99
(1) 4 Inlet
(1) 4 Outlet
ACCESS DOOR
ACCESS DOOR
53-3/4"
*14-612 to 14-912
(1) 6 Inlet
(1) 6 Outlet
ACCESS
DOOR
*MPT INLET
T
24-1/8"
ACCESS
DOOR
P
1 MPT MAKE-UP
2 MPT OVERFLOW
37-1/2"
*MPT OUTLET
13"
3"
5-1/8"
4-3/8"
38-1/4"
4' 1/2"
1"
Weights (LBS)
Model No.
Nominal
Tonnage
Shipping
Operating
AT-14-69
AT-14-79
AT-14-89
AT-14-99
AT-14-612
AT-14-712
AT-14-812
AT-14-912
76
86
90
100
115
129
137
150
2,000
2,160
2,100
2,260
2,530
2,730
2,570
2,770
3,600
3,760
3,700
3,860
4,700
4,900
4,740
4,940
NOTE:
(1)
(2)
(3)
(4)
5-7/8"
2 MPT DRAIN
24-1/4"
12-3/4"
19-3/4"
Heaviest
SectionF
1,380
1,540
1,480
1,640
1,770
1,970
1,810
2,010
Dimensions
Fan
Motor
(HP)
Air Flow
(CFM)
(2)2
(2)2
(2)3
(2)3
(2)3
(2)3
(2)5
(2)5
21,200
20,800
24,100
23,600
31,000
30,400
36,400
35,700
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
9 6-1/2
10 6-1/2
6 5
7 5
6 5
7 5
6 5
7 5
6 5
7 5
6 3
7 3
6 3
7 3
6 3
7 3
6 3
7 3
8 11-1/2
8 11-1/2
8 11-1/2
8 11-1/2
11 11-3/4
11 11-3/4
11 11-3/4
11 11-3/4
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
24
30-5/8"
ACCESS DOOR
21-3/8"
M
T
ACCESS
DOOR
6 BFW/GROOVED
INLET
2"
50-3/4"
H
P
2 MPT
MAKE-UP
48-1/4"
6 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
23-1/8"
14-7/8"
6-1/2"
5-1/4"
9"
3-5/8"
5 11-7/8"
Model No.
AT-19-46
AT-19-56L
AT-19-56
AT-19-66
AT-19-76U
AT-19-76L
AT-19-76
AT-19-86
AT-19-96E
AT-19-96U
AT-19-96L
AT-19-96
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
109
89
112
123
101
124
138
150
130
143
157
171
21-3/8"
3 FPT
DRAIN
50-3/4"
3/8"
8' 5-1/2"
Weights (LBS)
Shipping
Operating
3,420
3,000
3,060
3,100
3,200
3,260
3,300
3,330
3,480
3,520
3,550
3,620
150
5,460
5,040
5,100
5,140
5,240
5,300
5,340
5,370
5,520
5,560
5,590
5,660
150
Fan Motor
(HP)
Heaviest
SectionF
2,370
1,950
2,010
2,050
2,150
2,210
2,250
2,280
2,430
2,470
2,500
2,570
150
Dimensions
Air Flow
(CFM)
3
3
5
7.5
3
5
7.5
10
5
7.5
10
15
21,900
22,600
26,500
30-5/8"
30,200
M
22,200
26,100
29,700
32,500
25,700
29,200
32,000
36,300
12 8-1/4
8 8
SWING OUT RADIUS OF MOTOR COVER
10 8-1/4
6 8
10 8-1/4
6 8
10 8-1/4
6 8
DOOR
11 ACCESS
8-1/4
7 8
11 8-1/4
7 8
11 8-1/4
7 8
11 8-1/4
7 8
12 8-1/4
8 8
12 8-1/4
8 8
12 8-1/4
8 8
12 8-1/4
8 8
1 1
1 1
ACCESS
9 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
8 2-1/2
8 2-1/2
8 2-1/2
8 2-1/2
9 2-1/2
9 2-1/2
9 2-1/2
9 2-1/2
DOOR
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated
water.
T
6 BFW/GROOVED
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
INLET
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
50-3/4"
2"
Nominal Tonnage is based on 3 gpm per ton at 95
degree entering
water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
H
2 MPT
MAKE-UP
48-1/4"
6 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
23-1/8"
14-7/8"
6-1/2"
25
3-5/8"
7 5-7/8"
3/8"
5-1/4"
3 FPT
DRAIN
9"
50-3/4"
8' 5-1/2"
3-5/8"
5 11-7/8"
50-3/4"
3/8"
8' 5-1/2"
30-5/8"
ACCESS DOOR
21-3/8"
M
T
2"
ACCESS
DOOR
6 BFW/GROOVED
INLET
50-3/4"
H
P
2 MPT
MAKE-UP
48-1/4"
6 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
23-1/8"
14-7/8"
6-1/2"
3-5/8"
7 5-7/8"
Model No.
AT-19-28L
AT-19-28
AT-19-38
AT-19-48
AT-19-58U
AT-19-58L
AT-19-58
AT-19-68
AT-19-78E
AT-19-78U
AT-19-78L
AT-19-78
AT-19-88
AT-19-98
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
109
137
148
159
123
152
165
179
133
159
173
187
197
207
Operating
3,390
3,450
3,490
3,520
3,620
3,680
3,720
3,750
3,890
3,950
3,990
4,020
3,810
4,080
150
5,810
5,870
5,910
5,940
6,040
6,100
6,140
6,170
6,310
6,370
6,410
6,440
6,230
6,500
150
3 FPT
DRAIN
9"
50-3/4"
3/8"
8' 5-1/2"
Weights (LBS)
Shipping
5-1/4"
Heaviest
SectionF
2,220
2,280
2,320
2,350
2,450
2,510
2,550
2,580
2,720
2,780
2,820
2,850
2,640
2,910
150
Fan Motor
(HP)
Air Flow
(CFM)
3
5
7.5
10
3
5
7.5
10
3
5
7.5
10
15
15
26,600
31,300
35,700
39,200
26,200
30,800
35,100
37,800
25,800
30,300
34,500
37,800
43,700
43,000
Dimensions
H
10 8-1/4
10 8-1/4
10 8-1/4
10 8-1/4
11 8-1/4
11 8-1/4
11 8-1/4
11 8-1/4
12 8-1/4
12 8-1/4
12 8-1/4
12 8-1/4
11 8-1/4
12 8-1/4
1 5
6 8
6 8
6 8
6 8
6 8
6 8
7 8
7 8
8 8
8 8
8 8
8 8
7 8
8 8
1 5
7 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
7 2-1/2
8 2-1/2
9 2-1/2
9 2-1/2
9 2-1/2
9 2-1/2
8 2-1/2
9 2-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
26
30-5/8"
M
ACCESS DOOR
21-3/8"
M
T
2"
ACCESS
DOOR
8 BFW/GROOVED
INLET
4 5-3/4"
H
P
2 MPT
MAKE-UP
51-7/8"
8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
23-1/8"
14-7/8"
5-1/4"
3 FPT
DRAIN
7-1/2"
3-5/8"
8' 5-1/2"
Model No.
AT-19-59U
AT-19-59L
AT-19-59
AT-19-69E
AT-19-69U
AT-19-69L
AT-19-69
AT-19-79
AT-19-89E
AT-19-89U
AT-19-89L
AT-19-89
AT-19-99
UT Addition
Nominal
Tonnage
154
181
199
135
162
178
208
232
165
191
209
21-3/8"
242
265
3/8"
Shipping
Operating
4,250
4,290
4,320
3,980
4,020
4,050
4,120
4,390
4,560
4,600
4,630
4,700
4,750
150
7,090
7,130
7,160
6,820
6,860
6,890
6,960
7,230
7,400
7,440
7,470
7,540
7,590
150
(1)
(2)
(3)
(4)
4 5-3/4"
8 11-1/2"
Weights (LBS)
Heaviest
SectionF
2,940
2,980
3,010
2,670
2,710
2,740
2,810
3,080
3,250
3,290
3,320
3,390
3,440
T
150
2"
NOTE:
9"
Fan Motor
(HP)
Air Flow
(CFM)
5
7.5
10
5
7.5
10
15
15
5
7.5
10
15
20
35,300
40,100
43,900
35,900
40,800
44,700
50,800
49,800
34,700
39,500
43,200
49,000
53,600
Dimensions
30-5/8"
12 4-3/8
M
ACCESS DOOR
12 4-3/8
12 4-3/8
11 4-3/8
11 4-3/8
11 4-3/8
11 4-3/8
12 4-3/8
13 4-3/8
13 4-3/8
13 4-3/8
13 4-3/8
ACCESS
M
13 4-3/8 DOOR
8 BFW/GROOVED
1 9INLET
8 1/2
8 1/2
8 1/2
7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
9 1/2
1 9
8 7-1/8
8 7-1/8
8 7-1/8
7 7-1/8
7 7-1/8
7 7-1/8
7 7-1/8
8 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8
5 2-3/4"
An adequately sized bleed line must be installed in the cooling tower system toP prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change. 2 MPT
MAKE-UP
51-7/8" tower. Refer to EVAPCOs Equipment Layout Manual.
Adequate spacing must be allowed for access to the cooling
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature,
and 78 degree wet-bulb temperature.
8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
23-1/8"
14-7/8"
5-1/4"
3 FPT
DRAIN
7-1/2"
3-5/8"
8' 5-1/2"
27
3/8"
9"
5 2-3/4"
10 5-1/2
2 MPT
MAKE-UP
51-7/8"
8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
23-1/8"
14-7/8"
5-1/4"
One-Cell Cooling
Towers
3 FPT
DRAIN
7-1/2"
3-5/8"
8' 5-1/2"
9"
3/8"
4 5-3/4"
8 11-1/2"
30-5/8"
M
ACCESS DOOR
21-3/8"
M
ACCESS
DOOR
8 BFW/GROOVED
INLET
2"
5 2-3/4"
H
P
2 MPT
MAKE-UP
51-7/8"
8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
23-1/8"
14-7/8"
5-1/4"
3 FPT
DRAIN
7-1/2"
3-5/8"
8' 5-1/2"
Model No.
AT-19-111L
AT-19-111
AT-19-211
AT-19-311U
AT-19-311L
AT-19-311
AT-19-411
AT-19-511
AT-19-611E
AT-19-611U
AT-19-611L
AT-19-611
AT-19-711
AT-19-811
AT-19-911
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
156
187
202
172
202
221
231
256
190
220
238
270
285
298
314
9"
3/8"
10 5-1/2
Weights (LBS)
Shipping
Operating
4,530
4,570
4,600
4,850
4,890
4,920
4,670
4,990
5,200
5,240
5,270
5,340
5,040
5,390
5,420
150
7,830
7,870
7,900
8,150
8,190
8,220
7,970
8,290
8,500
8,540
8,570
8,640
8,340
8,690
8,720
150
5 2-3/4"
Heaviest
SectionF
3,060
3,100
3,130
3,380
3,420
3,450
3,200
3,520
3,730
3,770
3,800
3,870
3,570
3,920
3,950
150
Fan Motor
(HP)
Air Flow
(CFM)
5
7.5
10
5
7.5
10
15
15
5
7.5
10
15
20
20
25
40,200
45,800
50,200
39,700
45,100
49,400
57,100
56,100
39,000
44,300
48,600
55,100
61,300
60,300
64,600
Dimensions
H
11 4-3/8
11 4-3/8
11 4-3/8
12 4-3/8
12 4-3/8
12 4-3/8
11 4-3/8
12 4-3/8
13 4-3/8
13 4-3/8
13 4-3/8
13 4-3/8
12 4-3/8
13 4-3/8
13 4-3/8
1 9
7 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
9 1/2
1 9
7 7-1/8
7 7-1/8
7 7-1/8
8 7-1/8
8 7-1/8
8 7-1/8
7 7-1/8
8 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8
9 7-1/8
8 7-1/8
9 7-1/8
9 7-1/8
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
28
30-5/8"
M
ACCESS DOOR
21-3/8"
T
2"
ACCESS
DOOR
8 BFW/GROOVED
INLET
5 11-7/8"
H
P
2 MPT
MAKE-UP
56-1/4"
8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
23-1/8"
14-7/8"
7-1/2"
3-5/8"
8' 5-1/2"
Model No.
AT-19-412E
AT-19-412U
AT-19-412L
AT-19-412
AT-19-512U
AT-19-512L
AT-19-512
AT-19-612
AT-19-712E
AT-19-712U
AT-19-712L
21-3/8"
AT-19-712
AT-19-812
AT-19-912L
AT-19-912
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
203
230
257
283
229
256
289
319
243
268
299
330
340
M
352
363
5,080
5,110
5,190
5,230
5,440
5,470
5,550
5,590
5,830
5,860
5,940
5,980
5,610
6,000
6,020
150
9"
3 FPT
DRAIN
5 11-7/8"
3/8"
11 11-3/4"
Weights (LBS)
Shipping
5-1/4"
Operating
8,940
8,970
9,050
9,090
9,300
9,330
9,410
9,450
9,690
9,720
9,800
9,840
9,470
9,860
9,880
2"
150
Fan
Motor (HP)
Heaviest
SectionF
3,430
3,460
3,540
3,580
3,790
3,820
3,900
3,940
4,180
4,210
4,290
4,330
3,960
4,350
4,370
H 150
7.5
10
15
20
7.5
10
15
20
7.5
10
15
20
25
25
30
50,600
55,400
63,100
69,100
49,800
54,500
61,900
67,800
49,000
53,600
61,000
66,700
72,800
71,500
75,800
Dimensions
H
6 11-7/8"
7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
9 1/2
1 9
7 11-1/2
7 11-1/2
7 11-1/2
7 11-1/2
8 11-1/2
8 11-1/2
8 11-1/2
8 11-1/2
9 11-1/2
9 11-1/2
9 11-1/2
9 11-1/2
8 11-1/2
9 11-1/2
9 11-1/2
30-5/8"11 8-3/4
11M 8-3/4
ACCESS DOOR
11 8-3/4
11 8-3/4
12 8-3/4
12 8-3/4
12 8-3/4
12 8-3/4
13 8-3/4
13 8-3/4
13 8-3/4
13 8-3/4
12
8-3/4
ACCESS
M
DOOR
13 88BFW/GROOVED
3/4
INLET
13 8 3/4
1 9
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
2 MPT
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
MAKE-UP
56-1/4"
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature,
and 78 degree wet-bulb temperature.
8 BFW/GROOVED
OUTLET
F Heaviest section
23-1/8" is upper section.
14-7/8"
7-1/2"
29
3-5/8"
8' 5-1/2"
3/8"
5-1/4"
9"
3 FPT
OVERFLOW
3 FPT
DRAIN
6 11-7/8"
13 11-3/4"
14-7/8"
7-1/2"
5-1/4"
3 FPT
DRAIN
3/8"
8' 5-1/2"
9"
5 11-7/8"
11 11-3/4"
30-5/8"
M
ACCESS DOOR
21-3/8"
ACCESS
DOOR
8 BFW/GROOVED
INLET
2"
6 11-7/8"
H
P
2 MPT
MAKE-UP
56-1/4"
8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
23-1/8"
14-7/8"
7-1/2"
3-5/8"
8' 5-1/2"
Model No.
AT-19-114L
AT-19-114
AT-19-214L
AT-19-214
AT-19-314L
AT-19-314
AT-19-314M
AT-19-414
AT-19-514U
AT-19-514L
AT-19-514
AT-19-614
AT-19-714
AT-19-814
AT-19-914U
AT-19-914L
AT-19-914
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
221
251
249
280
280
309
337
315
266
295
329
347
377
399
361
391
413
5-1/4"
9"
3 FPT
DRAIN
6 11-7/8"
3/8"
13 11-3/4"
Weights (LBS)
Shipping
Operating
5,540
5,570
5,950
5,980
5,650
5,690
5,710
6,060
6,400
6,430
6,510
6,100
6,120
6,140
6,550
6,570
6,590
150
10,050
10,080
10,460
10,490
10,160
10,200
10,220
10,570
10,910
10,940
11,020
10,610
10,630
10,650
11,060
11,080
11,100
150
Heaviest
SectionF
3,680
3,710
4,090
4,120
3,790
3,830
3,850
4,200
4,540
4,570
4,650
4,240
4,260
4,280
4,690
4,710
4,730
150
Fan
Motor (HP)
7.5
10
7.5
10
15
20
25
15
7.5
10
15
20
25
30
20
25
30
55,900
61,300
55,100
60,300
69,800
76,500
82,000
68,600
54,200
59,300
67,500
75,000
80,400
85,200
73,800
79,100
83,800
Dimensions
H
11 8-3/4
11 8-3/4
12 8-3/4
12 8-3/4
11 8 3/4
11 8 3/4
11 8 3/4
12 8-3/4
13 8-3/4
13 8-3/4
13 8-3/4
12 8-3/4
12 8-3/4
12 8-3/4
13 8 3/4
13 8 3/4
13 8 3/4
1 9
7 1/2
7 1/2
8 1/2
8 1/2
7 1/2
7 1/2
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
8 1/2
8 1/2
8 1/2
9 1/2
9 1/2
9 1/2
1 9
7 11-1/2
7 11-1/2
8 11-1/2
8 11-1/2
7 11-1/2
7 11-1/2
7 11-1/2
8 11-1/2
9 11-1/2
9 11-1/2
9 11-1/2
8 11-1/2
8 11-1/2
8 11-1/2
9 11-1/2
9 11-1/2
9 11-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
30
7"
ACCESS
DOOR
T
2"
8 BFW/GROOVED
INLET
71-7/8"
P
2 MPT
MAKE-UP
62-1/4"
8 BFW/GROOVED
OUTLET
25-1/4"
16-7/8"
5-1/4"
7-1/4"
9' 9-3/4"
Model No.
AT-110-112L
AT-110-112
AT-110-212E
AT-110-212U
AT-110-212L
AT-110-212
AT-110-312
AT-110-412
AT-110-512
AT-110-612E
AT-110-612U
AT-110-612L
AT-110-612
AT-110-712
AT-110-812
AT-110-912
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
264
309
227
276
305
326
338
342
361
277
322
350
373
380
393
410
3/8"
Weights (LBS)
Shipping
Operating
6,840
6,840
6,290
6,360
6,410
6,460
6,890
6,560
6,940
7,190
7,260
7,310
7,360
7,040
7,460
7,710
700
12,380
12,380
11,830
11,900
11,950
12,000
12,430
12,100
12,480
12,730
12,800
12,850
12,900
12,580
13,000
13,250
700
Heaviest
SectionF
4,750
4,750
4,200
4,270
4,320
4,370
4,800
4,470
4,850
5,100
5,170
5,220
5,270
4,950
5,370
5,620
700
71-7/8"
11' 11-3/4"
Fan
Motor
(HP)
Air Flow
(CFM)
10
15
10
15
20
25
20
30
25
10
15
20
25
30
30
35
63,700
72,300
64,700
73,500
80,600
86,500
79,000
91,700
85,000
62,700
71,200
77,900
83,700
89,800
88,600
92,800
Dimensions
H
14 5-1/4
14 5-1/4
13 5-1/4
13 5-1/4
13 5-1/4
13 5-1/4
14 5-1/4
13 5-1/4
14 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
14 5-1/4
15 5-1/4
15 5-1/4
1 9-1/2
9 3
9 3
8 3
8 3
8 3
8 3
9 3
8 3
9 3
10 3
10 3
10 3
10 3
9 3
10 3
10 3
1 9-1/2
9 1
9 1
8 1
8 1
8 1
8 1
9 1
8 1
9 1
10 1
10 1
10 1
10 1
9 1
10 1
10 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
31
9"
3-5/8"
3 FPT
OVERFLOW
3 FPT
DRAIN
ACCESS DOOR
7"
2"
ACCESS
DOOR
10 BFW/GROOVED
INLET
108
P
2 MPT
MAKE-UP
62-1/4"
10 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
25-1/4"
5-1/4"
16-7/8"
3 FPT
DRAIN
9"
8-1/2"
9' 9-3/4"
Model No.
AT-110-118U
AT-110-118L
AT-110-118
AT-110-218L
AT-110-218
AT-110-318U
AT-110-318L
AT-110-318
AT-110-418L
AT-110-418
AT-110-518
AT-110-618
AT-110-718U
AT-110-718L
AT-110-718
AT-110-818
AT-110-918
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
290
351
389
364
420
333
395
437
420
445
471
499
460
493
522
547
570
108"
3-5/8"
3/8"
Weights (LBS)
Shipping
Operating
8,790
8,860
8,910
10,180
10,180
9,480
9,550
9,600
8,960
9,060
9,650
9,750
10,230
10,280
10,380
10,000
10,630
700
17,200
17,320
17,320
18,590
18,590
17,890
17,960
18,010
17,370
17,470
18,060
18,160
18,640
18,690
18,790
18,410
19,040
700
Heaviest
SectionF
5,640
5,710
5,760
7,030
7,030
6,330
6,400
6,450
5,710
5,810
6,500
6,600
7,080
7,130
7,230
6,850
7,480
700
18' 0"
Fan
Motor
(HP)
Air Flow
(CFM)
10
15
20
10
15
10
15
20
25
30
25
30
20
25
30
40
40
86,000
97,800
107,200
83,300
94,700
84,700
96,300
105,500
115,100
122,000
113,100
119,700
103,800
111,300
117,800
131,200
129,000
Dimensions
H
13 5-1/4
13 5-1/4
13 5-1/4
15 5-1/4
15 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
13 5-1/4
13 5-1/4
14 5-1/4
14 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
14 5-1/4
15 5-1/4
1 9-1/2
8 3
8 3
8 3
10 3
10 3
9 3
9 3
9 3
8 3
8 3
9 3
9 3
10 3
10 3
10 3
9 3
10 3
1 9-1/2
8 0
8 0
8 0
10 0
10 0
9 0
9 0
9 0
8 0
9 0
9 0
9 0
10 0
10 0
10 0
9 0
10 0
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
32
ACCESS DOOR
7"
ACCESS
DOOR
T
2"
8 BFW/GROOVED
INLET
71-7/8"
2 MPT
MAKE-UP
62-1/4"
8 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
25-1/4"
16-7/8"
7-1/4"
3-5/8"
5-1/4"
3 FPT
DRAIN
9"
11' 10"
Model No.
AT-112-012L
AT-112-012
AT-112-112
AT-112-212
AT-112-312U
AT-112-312L
AT-112-312
AT-112-412
AT-112-512U
AT-112-512L
AT-112-512
AT-112-612
AT-112-712
AT-112-812L
AT-112-812
AT-112-912
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
280
334
364
391
316
370
404
414
337
387
422
434
461
454
481
515
11' 11-3/4"
Weights (LBS)
Shipping
Operating
7,370
7,440
7,490
7,540
7,910
7,980
8,030
7,640
8,400
8,470
8,520
8,080
8,180
8,570
8,670
8,920
700
13,580
13,650
13,700
13,750
14,120
14,190
14,240
13,850
14,610
14,680
14,730
14,290
14,390
14,780
14,880
15,130
700
Heaviest
SectionF
4,930
5,000
5,050
5,100
5,470
5,540
5,590
5,200
5,960
6,030
6,080
5,640
5,740
6,130
6,230
6,480
700
Dimensions
Fan
Motor
(HP)
10
15
20
25
10
15
20
30
10
15
20
25
30
25
30
40
71,600
81,400
89,300
95,800
70,500
80,000
87,700
101,500
69,300
78,700
86,300
94,000
99,500
92,400
97,900
107,100
13 6-1/4
13 6-1/4
13 6-1/4
13 6-1/4
14 6-1/4
14 6-1/4
14 6-1/4
13 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
14 6-1/4
14 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
1 9-1/2
8 4
8 4
8 4
8 4
9 4
9 4
9 4
8 4
10 4
10 4
10 4
9 4
9 4
10 4
10 4
10 4
1 9-1/2
8 2
8 2
8 2
8 2
9 2
9 2
9 2
8 2
10 2
10 2
10 2
9 2
9 2
10 2
10 2
10 2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
33
71-7/8"
3/8"
7"
ACCESS
DOOR
T
2"
10 BFW/GROOVED
INLET
83-7/8"
2 MPT
MAKE-UP
68-1/4"
10 BFW/GROOVED
OUTLET
3 FPT
OVERFLOW
25-1/4"
16-7/8"
8-1/2"
3-5/8"
5-1/4"
3 FPT
DRAIN
9"
11' 10"
Model No.
AT-112-214
AT-112-314L
AT-112-314E
AT-112-314U
AT-112-314
AT-112-414E
AT-112-414U
AT-112-414L
AT-112-414
AT-112-514E
AT-112-514U
AT-112-514L
AT-112-514
AT-112-614
AT-112-714
AT-112-814
AT-112-914
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
299
425
359
394
450
344
405
439
471
370
427
460
494
501
524
548
574
83-7/8"
3/8"
13' 11-3/4"
Weights (LBS)
Shipping
Operating
8,010
8,200
8,080
8,140
8,270
8,670
8,740
8,800
8,860
9,190
9,260
9,320
9,380
8,930
9,450
9,190
9,710
700
15,340
15,530
15,410
15,470
15,600
16,000
16,070
16,130
16,190
16,520
16,590
16,650
16,710
16,260
16,780
16,520
17,040
700
Heaviest
SectionF
5,360
5,550
5,430
5,490
5,620
6,020
6,090
6,150
6,210
6,540
6,610
6,670
6,730
6,280
6,800
6,540
7,060
700
Dimensions
Fan
Motor
(HP)
10
25
15
20
30
10
15
20
25
10
15
20
25
30
30
40
40
77,800
104,100
88,500
97,000
110,400
76,600
87,000
95,400
102,300
75,300
85,600
93,800
100,600
108,300
106,600
118,600
116,600
14 1/4
14 1/4
14 1/4
14 1/4
14 1/4
15 1/4
15 1/4
15 1/4
15 1/4
16 1/4
16 1/4
16 1/4
16 1/4
15 1/4
16 1/4
15 1/4
16 1/4
1 9-1/2
8 4
8 4
8 4
8 4
8 4
9 4
9 4
9 4
9 4
10 4
10 4
10 4
10 4
9 4
10 4
9 4
10 4
1 9-1/2
8 7
8 7
8 7
8 7
8 7
9 7
9 7
9 7
9 7
10 7
10 7
10 7
10 7
9 7
10 7
9 7
10 7
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
34
ACCESS DOOR
ACCESS DOOR
SWINGS INSIDE UNIT
7"
ACCESS
DOOR
10 BFW/GROOVED
INLET
2"
P
2 MPT
MAKE-UP
74-1/4"
10 BFW/GROOVED
OUTLET
3 FPT OVERFLOW
25-1/4"
16-7/8"
5-1/4"
8-1/2"
9"
3-5/8"
11' 10"
Nominal
Tonnage
Model No.
AT-112-018U
AT-112-018L
AT-112-018
AT-112-118
AT-112-118M
AT-112-218U
AT-112-218L
AT-112-218
AT-112-318
AT-112-418E
AT-112-418U
AT-112-418L
AT-112-418
AT-112-518
AT-112-618
AT-112-718
AT-112-818
AT-112-918
UT Addition
NOTE:
(1)
(2)
(3)
(4)
439
497
525
554
610
488
546
581
614
518
572
606
642
675
705
724
757
785
3/8"
18
Weights (LBS)
Shipping
Operating
10,260
10,320
10,370
10,480
10,740
11,040
11,100
11,150
11,260
11,780
11,840
11,890
12,000
11,520
12,260
11,580
12,320
12,430
1,200
19,530
19,590
19,640
19,750
20,010
20,310
20,370
20,420
20,530
21,050
21,110
21,160
21,270
20,790
21,530
20,850
21,590
21,700
1,200
Heaviest
SectionF
7"
T
2"
Fan Motor
(HP)
Air Flow
(CFM)
15
20
25
30
40
15
20
25
30
15
20
25
30
40
40
50
50
60
110,100
120,600
129,600
137,400
150,500
108,500
118,700
127,400
135,000
106,700
116,800
125,400
132,900
147,700
145,300
158,500
155,600
165,000
6,700
6,760
6,810
6,920
7,180
7,480
7,540
7,590
7,700
8,220
8,280
8,330
8,440
7,960
8,700
8,020
8,760
8,870
1,200
H
10
Dimensions
H
14 6 1/4
8 4
14 6 1/4
8 4
ACCESS DOOR
14 ACCESS
6 1/4
4 UNIT
SWINGS8
INSIDE
DOOR
14 6 1/4
8 4
14 6 1/4
8 4
15 6 1/4
9 4
15 6 1/4
9 4
15 6 1/4
9 4
15 6 1/4
9 4
16 6 1/4
10 4
16 6 1/4
10 4
16 6 1/4
10 4
16 6 1/4
10 4
15 6 1/4
9 4
16 6 1/4
10 4
15 6 1/4
9 4
ACCESS
DOOR
16 6 1/4
10 4
16
1/4
10 4
10 6
BFW/GROOVED
1INLET
3-1/2
1 3-1/2
9 1
9 1
9 1
9 1
9 1
10 1
10 1
10 1
10 1
11 1
11 1
11 1
11 1
10 1
11 1
10 1
11 1
11 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights
are subject to change.
P
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
2 MPT
74-1/4"
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature,
MAKE-UP85 degree leaving water temperature, and 78 degree wet-bulb temperature.
3 FPT OVERFLOW
25-1/4"
8-1/2"
3-5/8"
11' 10"
10 BFW/GROOVED
OUTLET
35
3 FPT DRAIN
3/8"
5-1/4"
9"
3 FPT DRAIN
10
20
3-5/8"
3/8"
11' 10"
18
ACCESS DOOR
ACCESS DOOR
SWINGS INSIDE UNIT
7"
ACCESS
DOOR
T
2"
10 BFW/GROOVED
INLET
10
H
P
2 MPT
MAKE-UP
74-1/4"
10 BFW/GROOVED
OUTLET
3 FPT OVERFLOW
25-1/4"
16-7/8"
8-1/2"
3-5/8"
11' 10"
Nominal
Tonnage
Model No.
AT-112-320
AT-112-420
AT-112-520E
AT-112-520U
AT-112-520L
AT-112-520
AT-112-620E
AT-112-620U
AT-112-620L
AT-112-620
AT-112-720E
AT-112-720U
AT-112-720L
AT-112-720
AT-112-820
AT-112-920
UT Addition
NOTE:
(1)
(2)
(3)
(4)
459
536
506
544
625
679
572
618
655
728
585
623
698
757
788
817
5-1/4"
3 FPT DRAIN
9"
10
3/8"
20
Weights (LBS)
Shipping
Operating
11,020
11,750
11,070
11,180
11,440
11,500
12,650
12,700
12,810
13,070
11,800
11,910
12,170
12,230
13,130
13,240
1,200
21,420
22,150
21,470
21,580
21,840
21,900
23,050
23,100
23,210
23,470
22,200
22,310
22,570
22,630
23,530
23,640
1,200
Heaviest
SectionF
7,210
7,940
7,260
7,370
7,630
7,690
8,840
8,890
9,000
9,260
7,990
8,100
8,360
8,420
9,320
9,430
1,200
Fan Motor
(HP)
Air Flow
(CFM)
20
20
25
30
40
50
20
25
30
40
25
30
40
50
50
60
123,900
121,800
133,000
140,900
154,100
165,300
119,800
128,500
136,100
148,800
130,700
138,300
151,200
162,200
159,500
169,100
Dimensions
H
14 6 1/4
15 6 1/4
14 6 1/4
14 6 1/4
14 6 1/4
14 6 1/4
16 6 1/4
16 6 1/4
16 6 1/4
16 6 1/4
15 6 1/4
15 6 1/4
15 6 1/4
15 6 1/4
16 6 1/4
16 6 1/4
1 3-1/2
8 4
9 4
8 4
8 4
8 4
8 4
10 4
10 4
10 4
10 4
9 4
9 4
9 4
9 4
10 4
10 4
1 3-1/2
9 1
10 1
9 1
9 1
9 1
9 1
11 1
11 1
11 1
11 1
10 1
10 1
10 1
10 1
11 1
11 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
36
7"
ACCESS
DOOR
T
14 BFW/GOOVED
INLET
142-1/2"
2"
H
P
99-3/8"
4 FPT
OVERFLOW
14 BFW/GROOVED
OUTLET
26"
17-3/8"
9"
13' 11 1/4"
Model No.
AT-114-0124U
AT-114-0124L
AT-114-0124
AT-114-0224
AT-114-0324L
AT-114-0324
AT-114-0424
AT-114-0524
AT-114-0624E
AT-114-0624U
AT-114-0624L
AT-114-0624
AT-114-0724
AT-114-0824
AT-114-0924
AT-114-1024
AT-114-1124
AT-114-1224
AT-114-1324*
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
619
684
722
781
772
834
839
872
708
775
812
892
947
951
998
1,008
1,056
1,135
1,201
4-1/8"
3/8"
Weights (LBS)
Shipping
Operating
16,440
16,490
16,510
16,660
18,520
18,570
17,010
18,590
17,480
17,530
17,550
17,700
18,740
18,050
19,090
18,220
19,260
19,500
19,940
1,250
32,290
32,340
32,360
32,510
34,370
34,420
32,860
34,440
33,330
33,380
33,400
33,550
34,590
33,900
34,940
34,070
35,110
35,350
35,790
1,250
4 FPT
DRAIN
9"
Heaviest
SectionF
10,600
10,650
10,670
10,820
12,680
12,730
11,170
12,750
11,640
11,690
11,710
11,860
12,900
12,210
13,250
12,380
13,420
13,660
14,100
1,250
3 MPT
MAKE-UP
72-1/4"
142-1/2"
23'-9"
Fan
Motor
(HP)
Air Flow
(CFM)
20
25
30
40
20
25
50
30
20
25
30
40
40
50
50
60
60
75
100
159,500
170,100
180,300
197,600
152,100
163,200
212,300
173,400
157,100
168,500
177,400
194,100
190,900
208,500
205,000
220,600
217,100
238,000
255,100
Dimensions
H
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
17 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
18 5-5/8
19 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
9 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
10 2-1/4
11 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
11 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
12 3-7/8
13 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
* Model available with gear drive only. Motor and access door located on 13 11-1/4 unit end. Super Low Sound Fan is not available on this unit.
37
ACCESS DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
14 BFW/GROOVED
INLET
T
2"
154-1/2"
123-3/8"
4 FPT
OVERFLOW
14 BFW/GROOVED
OUTLET
26"
17-3/8"
9"
9"
4-1/8"
3 MPT
MAKE-UP
4 FPT
DRAIN
78-1/4"
154-1/2"
13' 11-1/4"
Model No.
AT-114-526
AT-114-626
AT-114-726
AT-114-826
AT-114-926
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,003
1,078
1,142
1,247
1,332
3/8"
25' 8-7/8"
Weights (LBS)
Shipping
Operating
24,800
24,860
24,960
25,280
25,300
D
41,630
41,690
41,790
42,110
42,130
2,400
Heaviest
SectionF
17,660
17,720
17,820
18,140
18,160
D
Dimensions
Fan
Motor
(HP)
(2)20
(2)25
(2)30
(2)40
(2)50
200,200
214,700
227,300
248,500
266,300
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2
12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
38
30-5/8
ACCESS DOOR
ACCESS DOOR
21-3/8
ACCESS
DOOR
T
2
(2) 6 BFW/GROOVED
INLET
ACCESS
DOOR
50-3/4
P
4 3-7/8
(2) 6 BFW/GROOVED
OUTLET
23-1/8
14-7/8
5-1/4
3-5/8
5 11-7/8
Model No.
AT-26-417
AT-26-517L
AT-26-517
AT-26-617
AT-26-717U
AT-26-717L
AT-26-717
AT-26-817
AT-26-917E
AT-26-917U
AT-26-917L
AT-26-917
21-3/8"
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
219
179
225
247
203
250
277
302
262
287
315
344
6-1/2
101-3/8
2-1/2
17' 1-1/2"
3/8
Weights (LBS)
Shipping
Operating
6,920
6,080
6,120
6,200
6,480
6,520
6,600
6,660
6,960
7,040
7,100
7,240
300
11,000
10,160
10,200
10,280
10,560
10,600
10,680
10,740
11,040
11,120
11,180
11,320
300
Fan Motor
(HP)
Heaviest
SectionF
2,410
1,990
2,010
2,050
2,190
2,210
2,250
2,280
2,430
2,470
2,500
2,570
150
(2)3
(2)3
(2)5
(2)7.5
(2) 3
(2)5
(2)7.5
(2)10
(2)5
(2)7.5
(2)10
(2)15
Dimensions
Air Flow
(CFM)
SWING
OUT RADIUS12
43,800
OF MOTOR COVER
30-5/8"
11-7/8
45,200
10 11-7/8
30-5/8"
53,100
10 11-7/8
60,500
ACCESS DOOR10 11-7/8
44,500
11 11-7/8
52,300
11 11-7/8
59,400
11 11-7/8
65,100
11 11-7/8
51,400
12 11-7/8
58,500
12 11-7/8
64,000
12 11-7/8
72,800
12 11-7/8
1 1
8 8
6 8
6 8
6 8 DOOR
ACCESS
7 8
7 8
7 8
7 8
8 8
8 8
8 8
8 8
1 1
ACCESS
ACCESS
DOOR
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up ofDOOR
impurities in (2)
the6recirculated
water.
BFW/GROOVED
T
Do not use catalog drawings for certified prints.
Dimensions and weights are subject to change.
INLET
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
50-3/4"
2" ton at 95 degree entering water temperature,
Nominal Tonnage is based on 3 gpm per
85 degree leaving water temperature, and 78 degree wet-bulb temperature.
H
4 8-1/4"
(2) 6 BFW/GROOVED
OUTLET
39
9 6
7 6
7 6
7 6
8 6
8 6
8 6
8 6
9 6
9 6
9 6
9 6
23-1/8"
14-7/8"
6-1/2"
3-5/8"
2-1/2"
23-1/8
14-7/8
6-1/2
5-1/4
3-5/8
5 11-7/8
101-3/8
2-1/2
3/8
17' 1-1/2"
30-5/8"
ACCESS DOOR
ACCESS DOOR
21-3/8"
ACCESS
DOOR
T
2"
(2) 6 BFW/GROOVED
INLET
ACCESS
DOOR
50-3/4"
P
4 8-1/4"
(2) 6 BFW/GROOVED
OUTLET
23-1/8"
14-7/8"
5-1/4"
3-5/8"
7 5-7/8"
Model No.
AT-28-217L
AT-28-217
AT-28-317
AT-28-417
AT-28-517U
AT-28-517L
AT-28-517
AT-28-617
AT-28-717E
AT-28-717U
AT-28-717L
AT-28-717
AT-28-817
AT-28-917
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
217
274
297
319
247
304
331
358
267
319
346
373
393
414
6-1/2"
101-3/8"
Weights (LBS)
Shipping
Operating
6,860
6,900
6,980
7,040
7,320
7,360
7,440
7,500
7,860
7,900
7,980
8,040
7,620
8,160
300
11,700
11,740
11,820
11,880
12,160
12,200
12,280
12,340
12,700
12,740
12,820
12,880
12,460
13,000
300
2-1/2"
17' 1-1/2"
3/8"
Heaviest
SectionF
2,260
2,280
2,320
2,350
2,490
2,510
2,550
2,580
2,760
2,780
2,820
2,850
2,640
2,910
150
Fan Motor
(HP)
Air Flow
(CFM)
(2)3
(2)5
(2)7.5
(2)10
(2)3
(2)5
(2)7.5
(2)10
(2) 3
(2)5
(2)7.5
(2)10
(2)15
(2)15
53,200
62,600
71,400
78,300
52,500
61,600
70,200
76,900
51,600
60,600
69,100
75,700
87,500
86,000
Dimensions
H
11 4-1/4
11 4-1/4
11 4-1/4
11 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
12 4-1/4
13 4-1/4
1 5
6 8
6 8
6 8
6 8
7 8
7 8
7 8
7 8
8 8
8 8
8 8
8 8
7 8
8 8
1 5
7 10-1/2
7 10-1/2
7 10-1/2
7 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
8 10-1/2
9 10-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
40
30-5/8"
ACCESS DOOR
ACCESS DOOR
ACCESS
DOOR
ACCESS
DOOR
21-3/8"
M
T
4 5-3/4"
2"
4 5-3/4"
P
2 MPT
MAKE-UP
60-1/4"
23-1/8"
14-7/8"
7-1/2"
8' 5 -1/2"
Nominal
Tonnage
Model No.
AT-29-318L
AT-29-318
AT-29-418
AT-29-518U
AT-29-518L
AT-29-518
AT-29-618
AT-29-718
AT-29-818E
AT-29-818U
AT-29-818L
AT-29-818
AT-29-918
UT Addition
NOTE:
(1)
(2)
(3)
(4)
274
329
362
312
368
404
422
471
335
387
425
491
538
9"
5-1/4"
4 5-3/4"
3-5/8"
3/8"
Weights (LBS)
Shipping
Operating
7,840
7,920
7,980
8,370
8,450
8,510
8,120
8,650
8,950
9,030
9,090
9,230
9,330
300
13,730
13,810
13,870
14,260
14,340
14,400
14,010
14,540
14,840
14,920
14,980
15,120
15,220
300
Fan
Motor (HP)
Heaviest
SectionF
5,290
5,370
5,430
5,820
5,900
5,960
5,570
6,100
6,400
6,480
6,540
6,680
6,780
300
4 5-3/4"
18
(2)5
(2)7.5
(2) 10
(2)5
(2)7.5
(2)10
(2)15
(2)15
(2)5
(2)7.5
(2)10
(2)15
(2)20
Dimensions
72,000
12 3/4
81,900
12 3/4
89,800
12 3/4
70,900
13 3/4
SWING OUT RADIUS
OF MOTOR COVER
80,600
13 3/4
30-5/8"
30-5/8"
88,200
13 3/4
M
ACCESS DOOR
102,000
12 3/4
100,100
13 3/4
69,700
14 3/4
79,300
14 3/4
86,800
14 3/4
98,400
14 3/4
107,600
14 3/4
1 9
7 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
ACCESS DOOR
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
9 1/2
1 9
8 3-1/2
8 3-1/2
8 3-1/2
9 3-1/2
9 3-1/2
9 3-1/2
8 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
21-3/8"
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
ACCESS
ACCESS
M spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment
M Layout
M
Adequate
DOOR Manual.
DOOR
T degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
Nominal Tonnage is based on 3 gpm per ton at 95
(2) 8 BFW/GROOVED INLET
5 3-3/4"
P
2 MPT
MAKE-UP
60-1/4"
23-1/8"
14-7/8"
41
7-1/2"
8' 5 -1/2"
3/8"
3-5/8"
9"
5-1/4"
5 3-3/4"
5 3-3/4"
21
5-1/4"
7-1/2"
8' 5 -1/2"
3-5/8"
3/8"
4 5-3/4"
4 5-3/4"
18
30-5/8"
ACCESS DOOR
ACCESS DOOR
ACCESS
DOOR
ACCESS
DOOR
21-3/8"
M
T
5 3-3/4"
2"
5 3-3/4"
P
2 MPT
MAKE-UP
60-1/4"
23-1/8"
9"
5-1/4"
14-7/8"
7-1/2"
8' 5 -1/2"
Nominal
Tonnage
Model No.
AT-29-121L
AT-29-121
AT-29-221L
AT-29-221
AT-29-321
AT-29-421L
AT-29-421
AT-29-521U
AT-29-521L
AT-29-521
AT-29-621
AT-29-721
AT-29-821
AT-29-921L
AT-29-921
UT Addition
NOTE:
(1)
(2)
(3)
(4)
315
379
347
410
448
408
467
383
445
482
518
547
578
604
636
3-5/8"
3/8"
Weights (LBS)
Shipping
Operating
8,920
9,000
9,530
9,610
9,670
9,060
9,200
10,190
10,270
10,330
9,810
10,470
9,910
10,570
10,630
300
15,860
15,940
16,470
16,550
16,610
16,000
16,140
17,130
17,210
17,270
16,750
17,410
16,850
17,510
17,570
300
Heaviest
SectionF
6,130
6,210
6,740
6,820
6,880
6,270
6,410
7,400
7,480
7,540
7,020
7,680
7,120
7,780
7,840
300
5 3-3/4"
5 3-3/4"
21
Fan
Motor (HP)
(2)5
(2)7.5
(2)5
(2)7.5
(2)10
(2)10
(2)15
(2)5
(2)7.5
(2)10
(2)15
(2)15
(2)20
(2)20
(2)25
80,700
91,800
79,600
90,500
99,200
100,700
114,600
78,200
88,900
97,500
112,500
110,700
123,000
120,900
129,800
Dimensions
H
12 3/4
12 3/4
13 3/4
13 3/4
13 3/4
12 3/4
12 3/4
14 3/4
14 3/4
14 3/4
13 3/4
14 3/4
13 3/4
14 3/4
14 3/4
1 9
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
7 1/2
7 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
8 1/2
9 1/2
9 1/2
1 9
8 3-1/2
8 3-1/2
9 3-1/2
9 3-1/2
9 3-1/2
8 3-1/2
8 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
42
30-5/8
ACCESS DOOR
ACCESS DOOR
21-3/8"
ACCESS
DOOR
ACCESS
DOOR
T
(2) 8 BFW/GROOVED
INLET
71-7/8"
2"
H
P
60-1/4"
(2) 8 BFW/GROOVED
OUTLET
(2) 3 FPT OVERFLOW
(2) 3 FPT DRAIN
23-1/8"
71-7/8"
14-7/8"
134-3/4"
7-1/2"
5-1/4"
3-5/8"
143-3/4"
8' 5-1/2"
Model No.
AT-29-024L
AT-29-024
AT-29-124L
AT-29-124
AT-29-224E
AT-29-224U
AT-29-224L
AT-29-224
AT-29-324
AT-29-424
AT-29-524
AT-29-624
AT-29-724
AT-29-824
AT-29-924
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
452
506
481
531
400
454
507
559
571
593
630
653
674
696
718
24' 2"
Weights (LBS)
Shipping
Operating
10,860
10,920
11,640
11,700
10,140
10,200
10,360
10,440
11,080
11,860
11,160
11,940
11,200
11,980
12,020
300
18,580
18,640
19,360
19,420
17,860
17,920
18,080
18,160
18,800
19,580
18,880
19,660
18,920
19,700
19,740
300
Heaviest
SectionF
3,790
3,820
4,180
4,210
3,430
3,460
3,540
3,580
3,900
4,290
3,940
4,330
3,960
4,350
4,370
150
Fan
Air Flow (CFM)
Motor (HP)
(2)7.5
(2)10
(2)7.5
(2)10
(2)7.5
(2)10
(2)15
(2)20
(2)15
(2)15
(2)20
(2)20
(2)25
(2)25
(2)30
98,600
107,900
96,900
106,200
100,100
109,700
124,900
137,000
122,600
120,700
134,100
132,100
144,000
141,600
150,100
Dimensions
H
13 3/4
13 3/4
14 3/4
14 3/4
12 3/4
12 3/4
12 3/4
12 3/4
13 3/4
14 3/4
13 3/4
14 3/4
13 3/4
14 3/4
14 3/4
1 9
8 1/2
8 1/2
9 1/2
9 1/2
7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
9 1/2
8 1/2
9 1/2
8 1/2
9 1/2
9 1/2
1 9
9 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
9 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
43
2-1/2"
3/8"
30 5/8"
ACCESS DOOR
ACCESS DOOR
ACCESS
DOOR
ACCESS
DOOR
21-3/8"
2"
T
(2) 8 BFW/GROOVED
INLET
83-7/8"
H
P
66-1/4"
(2) 8 BFW/GROOVED
OUTLET
83-7/8"
23-1/8"
Model No.
AT-29-128
AT-29-228U
AT-29-228L
AT-29-228
AT-29-328E
AT-29-328U
AT-29-328L
AT-29-328
AT-29-428
AT-29-528E
AT-29-528U
AT-29-528L
AT-29-528
AT-29-628
AT-29-728
AT-29-828
AT-29-928
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
446
502
563
633
506
563
622
678
698
535
592
661
726
757
787
802
830
167-3/4"
3-5/8"
3/8"
5-1/4"
7-1/2"
8' 5 1/2"
158-3/4"
14-7/8"
2-1/2"
28' 2"
Weights (LBS)
Shipping
Operating
11,140
11,960
12,020
12,180
11,200
11,360
11,440
11,480
12,260
12,860
12,920
13,080
13,160
12,300
13,200
12,340
13,240
300
20,160
20,980
21,040
21,200
20,220
20,380
20,460
20,500
21,280
21,880
21,940
22,100
22,180
21,320
22,220
21,360
22,260
300
Heaviest
SectionF
3,680
4,090
4,120
4,200
3,710
3,790
3,830
3,850
4,240
4,540
4,570
4,650
4,690
4,260
4,710
4,280
4,730
150
Fan
Air Flow (CFM)
Motor (HP)
(2)7.5
(2)7.5
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)20
(2)7.5
(2)10
(2)15
(2)20
(2)25
(2)25
(2)30
(2)30
112,300
110,700
121,100
137,800
123,000
140,200
153,600
164,700
150,600
108,800
119,200
135,600
148,300
161,600
159,000
171,200
168,200
Dimensions
H
12 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
13 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
13 6-3/4
14 6-3/4
13 6-3/4
14 6-3/4
1 9
7 1/2
8 1/2
8 1/2
8 1/2
7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
8 1/2
9 1/2
1 9
8 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
9 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
44
ACCESS DOOR
ACCESS
DOOR
ACCESS
DOOR
7"
T
2"
(2) 8 BFW/GROOVED
INLET
71-7/8"
H
P
74-1/4"
(2) 8 BFW/GROOVED
OUTLET
(2) 3 FPT OVERFLOW
(2) 2 MPT MAKE-UP
25-1/4"
16-7/8"
7-1/4"
71-7/8"
3-5/8"
9' 9-3/4"
143-3/4"
3/8"
2-1/2"
24' 2"
Model No.
AT-210-124L
AT-210-124
AT-210-224E
AT-210-224U
AT-210-224L
AT-210-224
AT-210-324
AT-210-424
AT-210-524
AT-210-624E
AT-210-624U
AT-210-624L
AT-210-624
AT-210-724
AT-210-824
AT-210-924
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
529
618
455
553
611
651
676
684
722
555
644
701
746
760
785
820
Weights (LBS)
Shipping
Operating
13,860
13,860
12,760
12,900
13,000
13,100
13,960
13,300
14,060
14,560
14,700
14,800
14,900
14,260
15,100
15,600
1,400
24,940
24,940
23,840
23,980
24,080
24,180
25,040
24,380
25,140
25,640
25,780
25,880
25,980
25,340
26,180
26,680
1,400
4,750
4,750
4,200
4,270
4,320
4,370
4,800
4,470
4,850
5,100
5,170
5,220
5,270
4,950
5,370
5,620
700
Dimensions
Fan
Motor
(HP)
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)20
(2)30
(2)25
(2)10
(2)15
(2)20
(2)25
(2)30
(2)30
(2)40
127,300
144,500
129,400
147,000
161,100
172,900
158,300
183,500
169,700
125,300
142,300
155,800
167,200
179,900
176,900
185,600
15 5-1/4
15 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
15 5-1/4
14 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
1 9-1/2
9 3
9 3
8 3
8 3
8 3
8 3
9 3
8 3
9 3
10 3
10 3
10 3
10 3
9 3
10 3
10 3
1 9-1/2
10 1
10 1
9 1
9 1
9 1
9 1
10 1
9 1
10 1
11 1
11 1
11 1
11 1
10 1
11 1
11 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
45
Heaviest
SectionF
ACCESS DOOR
7"
2"
ACCESS
DOOR
ACCESS
DOOR
(2) 10 BFW/GVD
INLET
108"
P
74-1/4"
(2) 10 BFW/GVD
OUTLET
(2) 3 FPT OVERFLOW
108"
25-1/4"
Model No.
AT-210-136U
AT-210-136L
AT-210-136
AT-210-236L
AT-210-236
AT-210-336U
AT-210-336L
AT-210-336
AT-210-436L
AT-210-436
AT-210-536
AT-210-636
AT-210-736U
AT-210-736L
AT-210-736
AT-210-836
AT-210-936
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
580
701
779
727
839
667
790
873
840
890
941
997
921
987
1,044
1,093
1,140
216
3-5/8"
3/8"
5-1/4
8-1/2"
9' 9-3/4"
207
16-7/8"
2-1/2
36' 2-1/2"
Weights (LBS)
Shipping
Operating
17,960
18,100
18,200
20,600
20,740
19,340
19,480
19,580
18,300
18,500
19,680
19,880
20,840
20,940
21,140
20,380
21,640
1,400
34,770
34,910
35,010
37,410
37,550
36,150
36,290
36,390
35,110
35,310
36,490
36,690
37,650
37,750
37,950
37,190
38,450
1,400
Heaviest
SectionF
5,640
5,710
5,760
6,960
7,030
6,330
6,400
6,450
5,810
5,910
6,500
6,600
7,080
7,130
7,230
6,850
7,480
700
Dimensions
Fan
Motor
(HP)
(2)10
(2)15
(2)20
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)30
(2)25
(2)30
(2)20
(2)25
(2)30
(2)40
(2)40
172,000
195,600
214,400
166,500
189,400
169,400
192,600
211,000
230,200
244,100
226,300
239,600
207,500
222,600
235,800
262,300
258,100
14 5-1/4
14 5-1/4
14 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
14 5-1/4
14 5-1/4
15 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
16 5-1/4
1 9-1/2
8 3
8 3
8 3
10 3
10 3
9 3
9 3
9 3
8 3
8 3
9 3
9 3
10 3
10 3
10 3
9 3
10 3
1 9-1/2
9 0
9 0
9 0
11 0
11 0
10 0
10 0
10 0
9 0
9 0
10 0
10 0
11 0
11 0
11 0
10 0
11 0
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
46
ACCESS DOOR
30-5/8"
SWING OUT RADIUS OF MOTOR COVER
30-5/8"
ACCESS DOOR
21-3/8"
21-3/8"
(2) 6 BFW/GROOVED
INLET
66-3/8"
ACCESS
DOOR
ACCESS
DOOR
T
2"
H
P
56-1/4"
(2) 3 MPT
OVERFLOW
(2) 6 BFW/GROOVED
OUTLET
62-7/8"
(2) 3 MPT
DRAIN
66-5/8"
67-5/8"
5-1/8"
12' 4-7/8"
Model No.
AT-212-49
AT-212-59L
AT-212-59
AT-212-69
AT-212-79U
AT-212-79L
AT-212-79
AT-212-89
AT-212-99E
AT-212-99U
AT-212-99L
AT-212-99
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
219
179
225
247
203
250
277
302
262
287
315
344
71-7/8"
16-7/8"
6-1/2"
3-5/8"
1-3/8"
Weights (LBS)
Shipping
Operating
6,920
6,080
6,120
6,200
6,480
6,520
6,600
6,660
6,960
7,040
7,100
7,240
300
11,000
10,160
10,200
10,280
10,560
10,600
10,680
10,740
11,040
11,120
11,180
11,320
300
Heaviest
SectionF
2,410
1,990
2,010
2,050
2,190
2,210
2,250
2,280
2,430
2,470
2,500
2,570
150
8' 5-1/2"
Dimensions
Fan
Motor
(HP)
(2)3
(2)3
(2)5
(2)7.5
(2)3
(2)5
(2)7.5
(2)10
(2)5
(2)7.5
(2)10
(2)15
43,800
45,200
53,100
60,500
44,500
52,300
59,400
65,100
51,400
58,500
64,000
72,800
13 4-1/4
11 4-1/4
11 4-1/4
11 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
1 1
8 8
6 8
6 8
6 8
7 8
7 8
7 8
7 8
8 8
8 8
8 8
8 8
1 1
7 10-1/2
9 10-1/2
7 10-1/2
7 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
47
23-1/8"
50-5/8"
(2) 2 MPT
MAKE-UP
ACCESS DOOR
7"
ACCESS
DOOR
2"
ACCESS
DOOR
(2) 8 BFW/GROOVED
INLET
71-7/8"
H
P
74-1/4"
(2) 8 BFW/GROOVED
OUTLET
(2) 3 FPT OVERFLOW
25-1/4"
71-7/8"
16-7/8"
134-3/4"
7-1/4"
11' 10"
Model No.
AT-212-024U
AT-212-024L
AT-212-024
AT-212-124L
AT-212-124
AT-212-224
AT-212-324
AT-212-424
AT-212-524
AT-212-624E
AT-212-624U
AT-212-624L
AT-212-624
AT-212-724
AT-212-824
AT-212-924
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
560
667
729
633
740
782
807
828
868
674
775
843
908
922
963
1,030
5-1/4"
3-5/8"
143-3/4"
3/8"
2-1/2"
24' 2"
Weights (LBS)
Shipping
Operating
14,560
14,840
14,940
15,640
15,920
15,040
16,020
15,240
16,120
16,620
16,900
17,000
17,100
16,320
17,300
17,800
1,400
26,980
27,260
27,360
28,060
28,340
27,460
28,440
27,660
28,540
29,040
29,320
29,420
29,520
28,740
29,720
30,220
1,400
Heaviest
SectionF
4,860
5,000
5,050
5,400
5,540
5,100
5,590
5,200
5,640
5,890
6,030
6,080
6,130
5,740
6,230
6,480
700
Dimensions
Fan
Motor
(HP)
(2)10
(2)15
(2)20
(2)10
(2)15
(2)25
(2)20
(2)30
(2)25
(2)10
(2)15
(2)20
(2)25
(2)30
(2)30
(2)40
143,100
162,700
178,300
140,900
160,100
191,500
175,300
202,900
188,000
138,600
157,500
172,400
184,800
199,000
195,700
214,300
14 6-1/4
14 6-1/4
14 6-1/4
15 6-1/4
15 6-1/4
14 6-1/4
15 6-1/4
14 6-1/4
15 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
15 6-1/4
16 6-1/4
16 6-1/4
1 9-1/2
8 4
8 4
8 4
9 4
9 4
8 4
9 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
10 4
10 4
1 9-1/2
9 2
9 2
9 2
10 2
10 2
9 2
10 2
9 2
10 2
11 2
11 2
11 2
11 2
10 2
11 2
11 2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
48
ACCESS DOOR
7"
2"
ACCESS
DOOR
ACCESS
DOOR
(2) 10 BFW/GROOVED
INLET
83-7/8"
P
86-1/4"
(2) 10 BFW/GROOVED
OUTLET
83-7/8"
25-1/4"
158-3/4"
16-7/8"
Model No.
AT-212-128E
AT-212-128U
AT-212-128L
AT-212-128
AT-212-228U
AT-212-228L
AT-212-228
AT-212-328
AT-212-428
AT-212-528E
AT-212-528U
AT-212-528L
AT-212-528
AT-212-628
AT-212-728
AT-212-828
AT-212-928
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
598
717
787
850
687
810
877
900
942
741
853
921
987
1,002
1,049
1,097
1,147
Weights (LBS)
Shipping
Operating
16,000
16,140
16,260
16,380
17,320
17,460
17,580
16,520
17,700
18,360
18,500
18,620
18,740
17,840
18,880
18,360
19,400
1,400
30,660
30,800
30,920
31,040
31,980
32,120
32,240
31,180
32,360
33,020
33,160
33,280
33,400
32,500
33,540
33,020
34,060
1,400
Heaviest
SectionF
5,360
5,430
5,490
5,550
6,020
6,090
6,150
5,620
6,210
6,540
6,610
6,670
6,730
6,280
6,800
6,540
7,060
700
2-1/2"
28' 2"
Dimensions
Fan
Motor
(HP)
(2)10
(2)15
(2)20
(2)25
(2)10
(2)15
(2)20
(2)30
(2)25
(2)10
(2)15
(2)20
(2)25
(2)30
(2)30
(2)40
(2)40
155,600
176,900
194,000
208,400
153,200
174,000
190,900
220,700
204,700
150,600
171,200
187,600
201,200
216,700
213,200
237,200
233,100
15 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
15 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
1 9-1/2
8 4
8 4
8 4
8 4
9 4
9 4
9 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
10 4
9 4
10 4
1 9-1/2
10 1
10 1
10 1
10 1
11 1
11 1
11 1
10 1
11 1
12 1
12 1
12 1
12 1
11 1
12 1
11 1
12 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
49
167-3/4"
3-5/8"
3/8"
5-1/4"
8-1/2"
11' 10"
ACCESS DOOR
ACCESS
DOOR
ACCESS
DOOR
7"
T
2"
(2) 10 BFW/GROOVED
INLET
108"
H
P
86-1/4"
(2) 10 BFW/GROOVED
OUTLET
(2) 3 FPT OVERFLOW
25-1/4"
108"
16-7/8"
207"
8-1/2"
5-1/4"
3-5/8"
11' 10"
Model No.
AT-212-036L
AT-212-036
AT-212-136E
AT-212-136U
AT-212-136L
AT-212-136
AT-212-136M
AT-212-236U
AT-212-236L
AT-212-236
AT-212-336L
AT-212-336
AT-212-436
AT-212-536
AT-212-636
AT-212-736
AT-212-836
AT-212-936
UT Addition
NOTE:
(1)
(2)
(3)
(4)
216"
3/8"
Nominal
Tonnage
977
1,092
877
994
1,051
1,107
1,219
1,035
1,145
1,213
1,161
1,227
1,283
1,350
1,409
1,448
1,513
1,570
Weights (LBS)
Shipping
Operating
22,340
22,460
20,780
20,900
21,000
21,220
21,740
23,820
23,940
24,040
22,560
22,780
24,260
23,300
24,780
23,420
24,900
25,120
2,400
40,880
41,000
39,320
39,440
39,540
39,760
40,280
42,360
42,480
42,580
41,100
41,320
42,800
41,840
43,320
41,960
43,440
43,660
2,400
Heaviest
SectionF
7,480
7,540
6,700
6,760
6,810
6,920
7,180
8,220
8,280
8,330
7,590
7,700
8,440
7,960
8,700
8,020
8,760
8,870
1,200
Fan
Motor
(HP)
Air Flow
(CFM)
(2)15
(2)20
(2)15
(2)20
(2)25
(2)30
(2)40
(2)15
(2)20
(2)25
(2)25
(2)30
(2)30
(2)40
(2)40
(2)50
(2)50
(2)60
216,900
237,300
220,200
241,200
259,200
274,700
300,900
213,300
233,600
250,800
254,700
270,100
265,800
295,500
290,700
317,100
311,400
329,900
Dimensions
H
16 6-1/4
16 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
15 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
1 3-1/2
9 4
9 4
8 4
8 4
8 4
8 4
8 4
10 4
10 4
10 4
9 4
9 4
10 4
9 4
10 4
9 4
10 4
10 4
1 3-1/2
11 1
11 1
10 1
10 1
10 1
10 1
10 1
12 1
12 1
12 1
11 1
11 1
12 1
11 1
12 1
11 1
12 1
12 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
50
AC C ES S DO OR
ACC E S S DO OR
7"
ACCESS
DOOR
2"
T
ACCESS
DOOR
(2) 10 BFW/GROOVED
INLET
120"
H
P
86-1/4"
(2) 10 BFW/GROOVED
OUTLET
120"
25-1/4"
Model No.
AT-212-0140
AT-212-0240
AT-212-0340
AT-212-0440
AT-212-0540
AT-212-0640
AT-212-0740
AT-212-0840
AT-212-0940
AT-212-1040
AT-212-1140
AT-212-1240
AT-212-1340
AT-212-1440
AT-212-1540
AT-212-1640
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
918
1,013
1,088
1,250
1,357
1,073
1,170
1,246
1,396
1,515
1,143
1,235
1,310
1,457
1,576
1,635
240"
3-5/8"
2-1/2
40'-2-1/2"
Weights (LBS)
Shipping
Operating
22,480
22,580
22,800
23,320
23,440
23,940
24,040
24,260
24,780
24,900
25,740
25,840
26,060
26,580
26,700
26,920
2,400
43,280
43,380
43,600
44,120
44,240
44,740
44,840
45,060
45,580
45,700
46,540
46,640
46,860
47,380
47,500
47,720
2,400
Heaviest
SectionF
7,210
7,260
7,370
7,630
7,690
7,940
7,990
8,100
8,360
8,420
8,840
8,890
9,000
9,260
9,320
9,430
1,200
Fan
Motor
(HP)
Air Flow
(CFM)
(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)40
(2)50
(2)60
246,500
264,600
280,300
306,600
329,000
242,400
260,000
275,300
300,900
322,600
238,300
255,700
270,900
296,200
317,300
336,300
Dimensions
H
15 6-1/2
15 6-1/2
15 6-1/2
15 6-1/2
15 6-1/2
16 6-1/2
16 6-1/2
16 6-1/2
16 6-1/2
16 6-1/2
17 6-1/2
17 6-1/2
17 6-1/2
17 6-1/2
17 6-1/2
17 6-1/2
1 3-1/2
8 4
8 4
8 4
8 4
8 4
9 4
9 4
9 4
9 4
9 4
10 4
10 4
10 4
10 4
10 4
10 4
1 3-1/2
10 1
10 1
10 1
10 1
10 1
11 1
11 1
11 1
11 1
11 1
12 1
12 1
12 1
12 1
12 1
12 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
51
234-3/4"
8-1/2"
3/8"
231"
16-7/8"
11'-10"
ACCESS DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
T
(2) 14 BFW/GROOVED
OUTLET
2"
142-1/2"
142-1/2"
P
99-3/8"
(2) 14 BFW/GROOVED
OUTLET
26"
9"
4-1/8"
142-1/2"
(2) 4 FPT
OVERFLOW
212-3/4"
285"
13' 11-1/4"
Model No.
AT-214-0148U
AT-214-0148L
AT-214-0148
AT-214-0248
AT-214-0348
AT-214-0448L
AT-214-0448
AT-214-0548
AT-214-0648E
AT-214-0648U
AT-214-0648L
AT-214-0648
AT-214-0748
AT-214-0848
AT-214-0948L
AT-214-0948
AT-214-1048
AT-214-1148
AT-214-1248*
UT Addition
NOTE:
(1)
(2)
(3)
(4)
2-1/2"
3/8"
Nominal
Tonnage
1,205
1,336
1,410
1,527
1,641
1,514
1,637
1,713
1,383
1,517
1,589
1,748
1,860
1,960
1,863
1,978
2,075
2,230
2,359
(2) 3 MPT
MAKE-UP
(2) 4 FPT
DRAIN
276"
17-3/8"
47' 8-1/2"
Weights (LBS)
Shipping
Operating
32,640
32,740
32,780
33,080
33,780
36,800
36,900
36,940
34,720
34,820
34,860
35,160
37,240
37,940
35,860
36,200
38,280
38,760
39,640
2,500
64,340
64,440
64,480
64,780
65,480
68,500
68,600
68,640
66,420
66,520
66,560
66,860
68,940
69,640
67,560
67,900
69,980
70,460
71,340
2,500
Heaviest
SectionF
10,600
10,650
10,670
10,820
11,170
12,680
12,730
12,750
11,640
11,690
11,710
11,860
12,900
13,250
12,210
12,380
13,420
13,660
14,100
1,250
Fan
Motor
(HP)
Air Flow
(CFM)
(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)20
(2)25
(2)30
(2)40
(2)40
(2)50
(2)50
(2)60
(2)60
(2)75
(2)100
313,500
336,700
357,000
391,200
420,400
301,100
323,100
343,300
308,800
331,200
351,100
384,300
378,000
405,900
412,500
436,800
429,900
471,200
505,100
Dimensions
H
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
* Model available with gear drive only. Motors and access doors located on 1311-1/4 unit ends. Super Low Sound Fan is not available on this unit.
52
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
(2) 14 BFW/GROOVED
INLET
2"
ACCESS
DOOR
154-1/2"
123-3/8"
(2) 14 BFW/GROOVED
OUTLET
26"
(2) 4 FPT
OVERFLOW
154-1/2"
17-3/8"
230-5/8"
9"
4-1/8"
13' 11-1/4"
Model No.
AT-214-552
AT-214-652
AT-214-752
AT-214-852
AT-214-952
UT Addition
NOTE:
(1)
(2)
(3)
(4)
2-1/2"
51' 8-1/4"
1,971
2,119
2,245
2,452
2,622
Weights (LBS)
Shipping
Operating
49,200
49,320
49,520
50,160
50,200
D
82,860
82,980
83,180
83,820
83,860
4,800
Heaviest
SectionF
17,660
17,720
17,820
18,140
18,160
D
Fan
Motor
(HP)
Air Flow
(CFM)
(4)20
(4)25
(4)30
(4)40
(4)50
393,500
422,100
446,800
488,700
523,700
Dimensions
H
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2
12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
53
308-7/8"
3/8"
Nominal
Tonnage
(2) 3 MPT
MAKE-UP
(2) 4 FPT
DRAIN
299-7/8"
ACCESS
DOOR
30-5/8"
30-5/8"
ACCESS
DOOR
21-3/8"
21-3/8"
ACCESS
DOOR
ACCESS
DOOR
(2) 6 BFW/GROOVED
INLET
T
2"
45"
H
56-1/4"
(2) 3 MPT
OVERFLOW
(2) 2 MPT
MAKE-UP
(2) 3 MPT
DRAIN
8' 5-1/2"
Model No.
AT-215-29L
AT-215-29
AT-215-39
AT-215-49
AT-215-59U
AT-215-59L
AT-215-59
AT-215-69
AT-215-79E
AT-215-79U
AT-215-79L
AT-215-79
AT-215-89
AT-215-99
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
217
274
297
319
247
304
331
358
267
319
346
373
393
414
5-1/8"
15' 4-7/8"
1- 3/8"
Weights (LBS)
Shipping
Operating
6,860
6,900
6,980
7,040
7,320
7,360
7,440
7,500
7,860
7,900
7,980
8,040
7,620
8,160
300
11,700
11,740
11,820
11,880
12,160
12,200
12,280
12,340
12,700
12,740
12,820
12,880
12,460
13,000
300
Heaviest
SectionF
2,260
2,280
2,320
2,350
2,490
2,510
2,550
2,580
2,760
2,780
2,820
2,850
2,640
2,910
150
Fan
Motor
(HP)
Air Flow
(CFM)
(2)3
(2)5
(2)7.5
(2)10
(2)3
(2)5
(2)7.5
(2)10
(2)3
(2)5
(2)7.5
(2)10
(2)15
(2)15
53,200
62,600
71,400
78,300
52,500
61,600
70,200
76,900
51,600
60,600
69,100
75,700
87,500
86,000
(2) 6 BFW/GROOVED
OUTLET
23-1/8"
68-5/8"
80-7/8"
14-7/8"
84-5/8"
6-1/2"
85-5/8"
3-5/8"
89-7/8"
Dimensions
H
11 4-1/4
11 4-1/4
11 4-1/4
11 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
12 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
13 4-1/4
12 4-1/4
13 4-1/4
1 5
6 8
6 8
6 8
6 8
7 8
7 8
7 8
7 8
8 8
8 8
8 8
8 8
7 8
8 8
1 5
7 10-1/2
7 10-1/2
7 10-1/2
7 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
8 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
9 10-1/2
8 10-1/2
9 10-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
* Model available with gear drive only. Motors and access doors located on 13 11-1/4 unit ends. Super Low Sound Fan is not available on this unit.
54
ACCESS DOOR
30-5/8"
30-5/8"
ACCESS DOOR
21-3/8"
21-3/8"
ACCESS
DOOR
ACCESS
DOOR
(2) 8 BFW/GROOVED
INLET
T
2"
50-3/4"
P
60-1/4"
(2) 3 MPT
OVERFLOW
(2) 2 MPT
MAKE-UP
(2) 3 MPT
DRAIN
8 11-1/2"
Model No.
AT-217-59U
AT-217-59L
AT-217-59
AT-217-69E
AT-217-69U
AT-217-69L
AT-217-69
AT-217-79
AT-217-89E
AT-217-89U
AT-217-89L
AT-217-89
AT-217-99
UT Addition
Nominal
Tonnage
5-1/8"
17' 4-1/8"
1-3/8"
Weights (LBS)
Shipping
Operating
308
8,500
14,180
362
8,580
14,260
399
8,640
14,320
270
7,960
13,640
324
8,040
13,720
OUT RADIUS OF MOTOR COVER
356 SWING8,100
13,780
416
8,240
13,920
464
8,780
14,460
330
9,120
14,800
381
9,200
14,880
418
9,260
14,940
484
9,400
15,080
530ACCESS 9,500 ACCESS 15,180
DOOR
DOOR
300
300 T
Heaviest
SectionF
2,940
2,980
3,010
ACCESS DOOR
2,670
2,710
2,740
2,810
30-5/8"
3,080
3,250
3,290
21-3/8"
3,320
3,390
3,440
150
Fan Motor
(HP)
Air Flow
(CFM)
(2)5
(2)7.5
(2)10
(2)5
(2)7.5
(2)10
(2)15
(2)15
(2)5
(2)7.5
(2)10
(2)15
(2)20
70,600
80,200
87,800
71,700
81,500
89,300
101,500
99,500
69,400
78,900
86,400
97,900
107,100
(2) 8 BFW/GROOVED
INLET
2"
NOTE:
(1)
(2)
(3)
(4)
80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"
23-1/8"
14-7/8"
7-1/2"
3-5/8"
Dimensions
H
13 3-3/8
13 3-3/8
13 3-3/8
12 3-3/8
12 3-3/8
12 3-3/8
12 3-3/8
13 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
1 9
8 3-1/8
8 3-1/8
8 3-1/8
7 3-1/8
730-5/8"
3-1/8
7 3-1/8
7 3-1/8
8 3-1/8
ACCESS DOOR
9 3-1/8
9 3-1/8
21-3/8"
9 3-1/8
9 3-1/8
9 3-1/8
1 9
9 3-1/2
9 3-1/2
9 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
50-3/4"
60-1/4"
10 5-1/2
55
(2) 8 BFW/GROOVED
OUTLET
1-3/8"
5-1/8"
17' 4-1/8"
(2) 8 BFW/GROOVED
OUTLET
80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"
23-1/8"
14-7/8"
7-1/2"
3-5/8"
8 11-1/2"
5-1/8"
17' 4-1/8"
97-1/4"
101-1/2"
3-5/8"
ACCESS DOOR
30-5/8"
30-5/8"
ACCESS DOOR
21-3/8"
21-3/8"
ACCESS
DOOR
ACCESS
DOOR
(2) 8 BFW/GROOVED
INLET
T
2"
50-3/4"
P
60-1/4"
(2) 3 MPT
OVERFLOW
(2) 2 MPT
MAKE-UP
(2) 3 MPT
DRAIN
1-3/8"
10 5-1/2
Model No.
AT-217-111L
AT-217-111
AT-217-211L
AT-217-211
AT-217-311
AT-217-411L
AT-217-411
AT-217-511U
AT-217-511L
AT-217-511
AT-217-611
AT-217-711
AT-217-811
AT-217-911L
AT-217-911
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
316
379
347
409
447
408
467
385
444
480
516
545
576
602
634
5-1/8"
17' 4-1/8"
Weights (LBS)
Shipping
Operating
9,060
9,140
9,700
9,780
9,840
9,200
9,340
10,400
10,480
10,540
9,980
10,680
10,080
10,780
10,840
300
15,660
15,740
16,300
16,380
16,440
15,800
15,940
17,000
17,080
17,140
16,580
17,280
16,680
17,380
17,440
300
Heaviest
SectionF
3,060
3,100
3,380
3,420
3,450
3,130
3,200
3,730
3,770
3,800
3,520
3,870
3,570
3,920
3,950
150
Fan Motor
(HP)
Air Flow
(CFM)
(2)5
(2)7.5
(2)5
(2)7.5
(2)10
(2)10
(2)15
(2)5
(2)7.5
(2)10
(2)15
(2)15
(2)20
(2)20
(2)25
80,700
91,800
79,600
90,500
99,100
100,700
114,600
78,200
88,900
97,400
112,500
110,600
123,000
120,900
129,700
(2) 8 BFW/GROOVED
OUTLET
80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"
23-1/8"
14-7/8"
7-1/2"
3-5/8"
Dimensions
H
12 3-3/8
12 3-3/8
13 3-3/8
13 3-3/8
13 3-3/8
12 3-3/8
12 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
13 3-3/8
14 3-3/8
13 3-3/8
14 3-3/8
14 3-3/8
1 9
7 3-1/8
7 3-1/8
8 3-1/8
8 3-1/8
8 3-1/8
7 3-1/8
7 3-1/8
9 3-1/8
9 3-1/8
9 3-1/8
8 3-1/8
9 3-1/8
8 3-1/8
9 3-1/8
9 3-1/8
1 9
8 3-1/2
8 3-1/2
9 3-1/2
9 3-1/2
10 3-1/2
8 3-1/2
8 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
56
ACCESS DOOR
30-5/8"
30-5/8"
ACCESS DOOR
21-3/8"
21-3/8"
ACCESS
DOOR
ACCESS
DOOR
(2) 8 BFW/GROOVED
INLET
T
2"
50-3/4"
P
5 1/4"
(2) 8 BFW/GROOVED
OUTLET
11 11-3/4"
Model No.
AT-217-412E
AT-217-412U
AT-217-412L
AT-217-412
AT-217-512U
AT-217-512L
AT-217-512
AT-217-612
AT-217-712E
AT-217-712U
AT-217-712L
AT-217-712
AT-217-812
AT-217-912L
AT-217-912
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
394
447
499
550
446
499
564
622
474
524
585
645
665
688
709
5-1/8"
1-3/8"
17' 4-1/8"
Weights (LBS)
Shipping
80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"
Heaviest
SectionF
Operating
10,160
17,880
3,430
10,220
17,940
3,460
10,380
18,100
3,540
10,460
18,180
3,580
10,880
18,600
3,790
10,940
18,660
3,820
11,100
18,820
3,900
11,180
18,900
3,940
ACCESS DOOR
SWING OUT RADIUS
OF MOTOR COVER4,180
11,660
19,380
11,720
19,440
4,210
11,880
19,600
4,29030-5/8"
11,960
19,680
4,330
11,220
18,940
3,960
12,000
19,720
4,350
12,040
19,760
4,370
21-3/8"
300
300
150
Fan Motor
(HP)
Air Flow
(CFM)
(2)7.5
(2)10
(2)15
(2)20
(2)7.5
(2)10
(2)15
(2)20
(2)7.5
(2)10
(2)15
(2)20
(2)25
(2)25
(2)30
99,600
109,100
124,300
136,200
98,100
107,300
122,000
133,500
96,500
105,600
120,100
131,400
143,200
140,800
149,300
23-1/8"
14-7/8"
7-1/2"
3-5/8"
Dimensions
H
12 3-3/8
12 3-3/8
12 3-3/8
12 3-3/8
13 3-3/8
13 3-3/8
13 3-3/8
13 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
14 3-3/8
13 3-3/8
14 3-3/8
14 3-3/8
1 9
7 3-1/8
7 3-1/8
7 3-1/8
7 3-1/8
8 3-1/8
8 3-1/8
8 3-1/8
8 3-1/8
30-5/8"
9 3-1/8
9 3-1/8
9 3-1/8
ACCESS
DOOR
9 3-1/8
8 3-1/8
9 3-1/8
9 3-1/8
21-3/8"
1 9
ACCESS
ACCESS
(2) 8 BFW/GROOVED
An adequately
sized bleed line
build-up of impurities in the recirculated water.
DOORmust be installed in the cooling tower system to prevent
DOOR
INLET
Do not use catalog drawings for certified prints. Dimensions
and weights are subject to
change.
T
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at
and 78 degree wet-bulb temperature.
50-3/4"
2" 95 degree entering water temperature, 85 degree leaving water temperature,
(2) 8 BFW/GROOVED
OUTLET
57
8 3-1/2
8 3-1/2
8 3-1/2
8 3-1/2
9 3-1/2
9 3-1/2
9 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
10 3-1/2
9 3-1/2
10 3-1/2
10 3-1/2
13 11-3/4"
1-3/8"
5-1/8"
17' 4-1/8"
80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"
23-1/8"
14-7/8"
7-1/2"
3-5/8"
11 11-3/4"
1-3/8"
17' 4-1/8"
3-5/8"
ACCESS DOOR
30-5/8"
30-5/8"
ACCESS DOOR
21-3/8"
21-3/8"
ACCESS
DOOR
ACCESS
DOOR
(2) 8 BFW/GROOVED
INLET
T
2"
50-3/4"
P
5 6-1/4"
(2) 8 BFW/GROOVED
OUTLET
13 11-3/4"
Model No.
AT-217-114
AT-217-214U
AT-217-214L
AT-217-214
AT-217-314E
AT-217-314U
AT-217-314L
AT-217-314
AT-217-414
AT-217-514E
AT-217-514U
AT-217-514L
AT-217-514
AT-217-614
AT-217-714
AT-217-814
AT-217-914
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
435
490
551
621
494
551
608
664
685
525
581
649
714
744
773
787
815
5-1/8"
1-3/8"
17' 4-1/8"
Weights (LBS)
Shipping
Operating
11,080
11,900
11,960
12,120
11,140
11,300
11,380
11,420
12,200
12,800
12,860
13,020
13,100
12,240
13,140
12,280
13,180
300
20,100
20,920
20,980
21,140
20,160
20,320
20,400
20,440
21,220
21,820
21,880
22,040
22,120
21,260
22,160
21,300
22,200
300
80-1/4"
92-1/2"
96-1/4"
97-1/4"
101-1/2"
Heaviest
SectionF
3,680
4,090
4,120
4,200
3,710
3,790
3,830
3,850
4,240
4,540
4,570
4,650
4,690
4,260
4,710
4,280
4,730
150
Fan Motor
(HP)
Air Flow
(CFM)
(2)7.5
(2)7.5
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)20
(2)7.5
(2)10
(2)15
(2)20
(2)25
(2)25
(2)30
(2)30
112,300
110,600
121,100
137,700
123,000
140,200
153,600
164,700
150,600
108,800
119,100
135,500
148,300
161,500
158,900
171,100
168,200
23-1/8"
14-7/8"
7-1/2"
3-5/8"
Dimensions
H
12 9-3/8
13 9-3/8
13 9-3/8
13 9-3/8
12 9-3/8
12 9-3/8
12 9-3/8
12 9-3/8
13 9-3/8
14 9-3/8
14 9-3/8
14 9-3/8
14 9-3/8
13 9-3/8
14 9-3/8
13 9-3/8
14 9-3/8
1 9
7 3-1/8
8 3-1/8
8 3-1/8
8 3-1/8
7 3-1/8
7 3-1/8
7 3-1/8
7 3-1/8
8 3-1/8
9 3-1/8
9 3-1/8
9 3-1/8
9 3-1/8
8 3-1/8
9 3-1/8
8 3-1/8
9 3-1/8
1 9
8 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
9 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
58
ACCESS DOOR
ACCESS DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
2"
(2) 8 BFW/GROOVED
INLET
58-7/8"
P
74-1/4"
(2) 8 BFW/GROOVED
OUTLET
25-1/4"
93-5/8"
108-3/4"
16-7/8"
112-1/2"
7- 1/4"
113-1/2"
Model No.
AT-220-112L
AT-220-112
AT-220-212E
AT-220-212U
AT-220-212L
AT-220-212
AT-220-312
AT-220-412
AT-220-512
AT-220-612E
AT-220-612U
AT-220-612L
AT-220-612
AT-220-712
AT-220-812
AT-220-912
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
529
618
455
553
611
651
676
684
722
555
644
701
746
760
785
820
Weights (LBS)
Shipping
Operating
14,000
14,000
12,900
13,040
13,140
13,240
14,100
13,440
14,200
14,700
14,840
14,940
15,040
14,400
15,240
15,740
1,400
25,080
25,080
23,980
24,120
24,220
24,320
25,180
24,520
25,280
25,780
25,920
26,020
26,120
25,480
26,320
26,820
1,400
Heaviest
SectionF
4,750
4,750
4,200
4,270
4,320
4,370
4,800
4,470
4,850
5,100
5,170
5,220
5,270
4,950
5,370
5,620
700
Fan
Motor (HP)
Air Flow
(CFM)
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)20
(2)30
(2)25
(2)10
(2)15
(2)20
(2)25
(2)30
(2)30
(2)35
126,700
143,900
128,800
146,300
160,300
172,300
157,400
182,600
169,100
124,700
141,600
155,000
166,300
179,000
176,300
185,000
117-3/4"
Dimensions
H
15 5-1/4
15 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
14 5-1/4
15 5-1/4
14 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
1 9-1/2
9 3
9 3
8 3
8 3
8 3
8 3
9 3
8 3
9 3
10 3
10 3
10 3
10 3
9 3
10 3
10 3
1 9-1/2
10 1
10 1
9 1
9 1
9 1
9 1
10 1
9 1
10 1
11 1
11 1
11 1
11 1
10 1
11 1
11 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
59
5-1/8"
20' 5/8"
1-3/8"
11' 11-3/4"
3-5/8"
ACCESS DOOR
ACCESS DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
(2) 10 BFW/GROOVED
INLET
2"
58-7/8"
P
25-1/4"
86-1/4"
(2) 10 BFW/GROOVED
OUTLET
93-5/8"
108-3/4"
16-7/8"
112-1/2"
113-1/2"
117-3/4"
5-1/8"
18' 0"
Model No.
AT-220-118U
AT-220-118L
AT-220-118
AT-220-218L
AT-220-218
AT-220-318U
AT-220-318L
AT-220-318
AT-220-418L
AT-220-418
AT-220-518
AT-220-618
AT-220-718U
AT-220-718L
AT-220-718
AT-220-818
AT-220-918
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
580
701
779
727
839
667
790
873
840
890
941
997
921
987
1,044
1,093
1,140
Weights (LBS)
Operating
17,820
17,960
18,060
20,600
20,600
19,200
19,340
19,440
18,160
18,360
19,540
19,740
20,700
20,800
21,000
20,240
21,500
1,400
34,630
34,770
34,870
37,410
37,410
36,010
36,150
36,250
34,970
35,170
36,350
36,550
37,510
37,610
37,810
37,050
38,310
1,400
3-5/8
20' 5/8"
1-3/8"
Shipping
8-1/2"
Heaviest
SectionF
5,640
5,710
5,760
7,030
7,030
6,330
6,400
6,450
5,810
5,910
6,500
6,600
7,080
7,130
7,230
6,850
7,480
700
Fan
Motor (HP)
Air Flow
(CFM)
(2)10
(2)15
(2)20
(2)10
(2)15
(2)10
(2)15
(2)20
(2)25
(2)30
(2)25
(2)30
(2)20
(2)25
(2)30
(2)40
(2)40
171,200
194,700
213,600
165,700
188,600
168,600
191,700
210,000
229,100
243,000
225,200
238,600
206,500
221,600
234,800
261,000
256,800
Dimensions
H
15 5-1/4
15 5-1/4
15 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
17 5-1/4
1 9-1/2
8 3
8 3
8 3
10 3
10 3
9 3
9 3
9 3
8 3
8 3
9 3
9 3
10 3
10 3
10 3
9 3
10 3
1 9-1/2
10 0
10 0
10 0
12 0
12 0
11 0
11 0
11 0
10 0
10 0
11 0
11 0
12 0
12 0
12 0
11 0
12 0
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
60
ACCESS
DOOR
ACCESS DOORS SWING INSIDE UNIT
ACCESS
DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
T
71"
(2) 10 BFW/GROOVED
INLET
2"
H
P
98-1/4"
(2) 10 BFW/GROOVED
OUTLET
25-1/4"
16-7/8"
117-7/8"
(2) 2 MPT MAKE-UP
Model No.
AT-224-018U
AT-224-018L
AT-224-018
AT-224-118
AT-224-218U
AT-224-218L
AT-224-218
AT-224-318
AT-224-418
AT-224-518E
AT-224-518U
AT-224-518L
AT-224-518
AT-224-618
AT-224-718
AT-224-818L
AT-224-818
AT-224-918
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
877
994
1,051
1,107
977
1,092
1,161
1,219
1,227
1,035
1,145
1,213
1,283
1,350
1,448
1,409
1,513
1,570
1- 3/8"
142"
24' 1-1/8"
Weights (LBS)
Shipping
Operating
20,840
20,960
21,060
21,280
22,400
22,520
22,620
21,800
22,840
23,880
24,000
24,100
24,320
23,360
23,480
24,840
24,960
25,180
2,400
39,380
39,500
39,600
39,820
40,940
41,060
41,160
40,340
41,380
42,420
42,540
42,640
42,860
41,900
42,020
43,380
43,500
43,720
2,400
Heaviest
SectionF
6,700
6,760
6,810
6,920
7,480
7,540
7,590
7,180
7,700
8,220
8,280
8,330
8,440
7,960
8,020
8,700
8,760
8,870
1,200
Fan
Motor (HP)
Air Flow
(CFM)
(2)15
(2)20
(2)25
(2)30
(2)15
(2)20
(2)25
(2)40
(2)30
(2)15
(2)20
(2)25
(2)30
(2)40
(2)50
(2)40
(2)50
(2)60
219,400
240,300
258,200
274,000
216,100
236,500
254,100
300,100
268,800
212,500
232,700
249,800
264,800
294,400
315,900
289,300
310,300
328,700
Dimensions
H
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2
8 4
8 4
8 4
8 4
9 4
9 4
9 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
9 4
10 4
10 4
10 4
1 3-1/2
11 1
11 1
11 1
11 1
12 1
12 1
12 1
11 1
12 1
13 1
13 1
13 1
13 1
12 1
12 1
13 1
13 1
13 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
61
3-5/8"
137-3/4"
5-1/8"
18' 0"
8-1/2"
133"
136-3/4"
ACCESS
DOOR
ACCESS DOORS SWING INSIDE UNIT
ACCESS
DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
T
71"
(2) 10 BFW/GROOVED
INLET
2"
H
P
98-1/4"
(2) 12 BFW/GROOVED
OUTLET
25-1/4"
16-7/8"
117-7/8"
(2) 2 MPT MAKE-UP
137-3/4"
5-1/8"
1- 3/8"
Model No.
AT-224-120
AT-224-220
AT-224-320
AT-224-420L
AT-224-420
AT-224-520L
AT-224-520
AT-224-620U
AT-224-620L
AT-224-620
AT-224-720E
AT-224-720U
AT-224-720L
AT-224-720
AT-224-820
AT-224-920
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
893
986
1,061
1,220
1,324
1,046
1,142
1,219
1,366
1,482
1,119
1,210
1,284
1,428
1,545
1,603
Operating
22,300
22,400
22,620
23,140
23,260
23,760
23,860
24,080
24,600
24,720
25,560
25,660
25,880
26,400
26,520
26,740
2,400
43,100
43,200
43,420
43,940
44,060
44,560
44,660
44,880
45,400
45,520
46,360
46,460
46,680
47,200
47,320
47,540
2,400
142"
24' 1-1/8"
Weights (LBS)
Shipping
3-5/8"
136-3/4"
20' 0"
9 1/2"
133"
Heaviest
SectionF
7,210
7,260
7,370
7,630
7,690
7,940
7,990
8,100
8,360
8,420
8,840
8,890
9,000
9,260
9,320
9,430
1,200
Fan
Motor (HP)
Air Flow
(CFM)
(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)40
(2)50
(2)60
244,300
262,200
277,900
304,000
326,100
240,300
257,800
272,900
298,300
319,800
236,300
253,500
268,500
293,700
314,700
333,500
Dimensions
H
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2
8 4
8 4
8 4
8 4
8 4
9 4
9 4
9 4
9 4
9 4
10 4
10 4
10 4
10 4
10 4
10 4
1 3-1/2
11 1
11 1
11 1
11 1
11 1
12 1
12 1
12 1
12 1
12 1
13 1
13 1
13 1
13 1
13 1
13 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
62
ACCESS
DOORS SWING
INSIDE UNIT
ACCESS
DOOR
ACCESS
DOOR
7"
ACCESS
DOOR
142-1/2"
2"
ACCESS
DOOR
(2) 14 BFW/GROOVED
INLET
99-3/8"
P
(2) 14 BFW/GROOVED OUTLET
138"
26"
157-3/8"
23' 9"
Model No.
AT-228-0124E
AT-228-0124U
AT-228-0124L
AT-228-0124
AT-228-0224
AT-228-0324L
AT-228-0324
AT-228-0424
AT-228-0524E
AT-228-0524U
AT-228-0524L
AT-228-0524
AT-228-0624
AT-228-0724
AT-228-0824U
AT-228-0824L
AT-228-0824
AT-228-0924
AT-228-1024*
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,198
1,329
1,402
1,520
1,633
1,508
1,630
1,706
1,376
1,510
1,582
1,740
1,855
1,969
1,853
1,952
2,067
2,221
2,350
5-1/8"
28' 3-5/8"
1- 3/8"
Weights (LBS)
Shipping
Operating
32,320
32,420
32,460
32,760
33,460
36,480
36,580
36,620
34,400
34,500
34,540
34,840
35,540
35,880
37,920
37,620
37,960
38,440
39,320
2,500
64,020
64,120
64,160
64,460
65,160
68,180
68,280
68,320
66,100
66,200
66,240
66,540
67,240
67,580
68,620
69,320
69,660
70,140
71,020
2,500
Heaviest
SectionF
10,600
10,650
10,670
10,820
11,170
12,680
12,730
12,750
11,640
11,690
11,710
11,860
12,210
12,380
12,900
13,250
13,420
13,660
14,100
1,250
17-3/8"
161-5/8"
Fan
Motor (HP)
Air Flow
(CFM)
(2)20
(2)25
(2)30
(2)40
(2)50
(2)20
(2)25
(2)30
(2)20
(2)25
(2)30
(2)40
(2)50
(2)60
(2)40
(2)50
(2)60
(2)75
(2)100
312,300
335,200
355,000
389,400
418,200
300,300
322,200
342,300
307,600
330,000
349,300
382,400
410,500
434,800
376,600
404,400
427,800
468,800
502,600
9"
162-1/8"
167-1/4"
4-1/8"
Dimensions
H
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
* Model available with gear drive only. Motors and access doors located on 283-5/8 unit end. Super Low Sound Fan is not available on this unit.
63
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
T
(2) 14 BFW/GROOVED
INLET
2"
83-5/8"
P
123-3/8"
26"
(2) 14 BFW/GROOVED
OUTLET
17-3/8"
138"
9"
4"
157-1/4"
161-1/2"
162-1/2"
5-1/8"
25' 8-7/8"
Model No.
AT-228-526
AT-228-626
AT-228-726
AT-228-826
AT-228-926
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,963
2,111
2,236
2,443
2,613
1-3/8"
Weights (LBS)
Shipping
Operating
48,940
49,060
49,260
49,900
49,940
D
82,600
82,720
82,920
83,560
83,600
4,800
Heaviest
SectionF
17,660
17,720
17,820
18,140
18,160
D
167-1/4"
28' 3-5/8"
Fan
Motor
(HP)
Air Flow
(CFM)
(4)20
(4)25
(4)30
(4)40
(4)50
392,000
420,400
445,100
486,800
521,700
Dimensions
H
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2
12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
64
30-5/8"
30-5/8"
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
21-3/8"
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
T
(3) 8 BFW/GROOVED
INLET
71-7/8"
2"
H
P
66-1/4"
9"
5-1/4"
23-1/8"
14-7/8"
134-3/4"
3-5/8"
143-3/4"
Model No.
AT-39-136
AT-39-236
AT-39-336L
AT-39-336
AT-39-436
AT-39-536
AT-39-636U
AT-39-636L
AT-39-636
AT-39-736
AT-39-836
AT-39-936E
AT-39-936U
AT-39-936L
AT-39-936
UT Addition
NOTE:
(1)
(2)
(3)
(4)
2-1/2"
725
800
605
686
765
843
682
763
862
951
1,016
893
984
1,050
1,082
36' 4-1/4"
Weights (LBS)
Shipping
Operating
17,550
17,640
15,300
15,390
15,630
15,750
16,380
16,470
16,710
16,830
16,890
17,880
18,000
18,060
18,120
450
29,130
29,220
26,880
26,970
27,210
27,330
27,960
28,050
28,290
28,410
28,470
29,460
29,580
29,640
29,700
450
Heaviest
SectionF
4,180
4,210
3,430
3,460
3,540
3,580
3,790
3,820
3,900
3,940
3,960
4,290
4,330
4,350
4,370
150
Fan
Motor (HP)
Air Flow
(CFM)
(3)7.5
(3)10
(3)7.5
(3)10
(3)15
(3)20
(3)7.5
(3)10
(3)15
(3)20
(3)25
(3)15
(3)20
(3)25
(3)30
146,100
159,900
150,900
165,200
188,200
206,200
148,600
162,500
184,900
202,200
217,100
181,900
198,900
213,200
226,200
Dimensions
H
14 6-3/4
14 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
1 9
9 1/2
9 1/2
7 1/2
7 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
8 1/2
8 1/2
9 1/2
9 1/2
9 1/2
9 1/2
1 9
10 9-1/2
10 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
65
3/8"
Nominal
Tonnage
71-7/8"
7-1/2"
8' 5-1/2"
(3) 8 BFW/GROOVED
OUTLET
30-5/8"
30-5/8"
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
21-3/8"
2
T
(3) 8 BFW/GROOVED
INLET
83-7/8"
H
P
66-1/4"
(3) 8 BFW/GROOVED
OUTLET
23-1/8"
83-7/8"
7-1/2"
5-1/4
3-5/8"
8' 5-1/2"
Model No.
AT-39-142
AT-39-242L
AT-39-242
AT-39-342
AT-39-442L
AT-39-442
AT-39-542L
AT-39-542
AT-39-642E
AT-39-642U
AT-39-642L
AT-39-642
AT-39-742U
AT-39-742L
AT-39-742
AT-39-842
AT-39-942
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
748
664
754
840
799
884
927
1,011
839
945
1,042
1,130
986
1,084
1,174
1,197
1,239
158-3/4"
14-7/8"
167-3/4
2-1/2"
3/8"
42' 4-1/4"
Weights (LBS)
Shipping
Operating
17,910
16,680
16,770
17,010
19,260
19,350
17,130
17,190
18,000
18,240
18,360
18,420
19,590
19,710
19,770
18,480
19,830
450
31,440
30,210
30,300
30,540
32,790
32,880
30,660
30,720
31,530
31,770
31,890
31,950
33,120
33,240
33,300
32,010
33,360
450
Heaviest
SectionF
4,090
3,680
3,710
3,790
4,540
4,570
3,830
3,850
4,120
4,200
4,240
4,260
4,650
4,690
4,710
4,280
4,730
150
Fan
Motor (HP)
Air Flow
(CFM)
(3)7.5
(3)7.5
(3)10
(3)15
(3)7.5
(3)10
(3)20
(3)25
(3)10
(3)15
(3)20
(3)25
(3)15
(3)20
(3)25
(3)30
(3)30
165,200
167,700
183,700
209,300
162,400
177,900
229,300
246,200
180,800
205,600
224,900
241,300
202,400
221,400
237,400
255,700
251,200
Dimensions
H
13 6-3/4
12 6-3/4
12 6-3/4
12 6-3/4
14 6-3/4
14 6-3/4
12 6-3/4
12 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
13 6-3/4
14 6-3/4
14 6-3/4
14 6-3/4
13 6-3/4
14 6-3/4
1 9
8 1/2
7 1/2
7 1/2
7 1/2
9 1/2
9 1/2
7 1/2
7 1/2
8 1/2
8 1/2
8 1/2
8 1/2
9 1/2
9 1/2
9 1/2
8 1/2
9 1/2
1 9
9 9-1/2
8 9-1/2
8 9-1/2
8 9-1/2
10 9-1/2
10 9-1/2
8 9-1/2
8 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
9 9-1/2
10 9-1/2
10 9-1/2
10 9-1/2
9 9-1/2
10 9-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
66
ACCESS DOOR
ACCESS DOOR
7"
(3) 8 BFW/GROOVED
INLET
71-7/8
2"
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
H
P
86-1/4"
25-1/4"
5-1/4"
16-7/8"
7-1/4"
3-5/8"
71-7/8"
134-3/4"
9' 9-3/4"
Model No.
AT-310-136L
AT-310-136
AT-310-236E
AT-310-236U
AT-310-236L
AT-310-236
AT-310-336
AT-310-436
AT-310-536
AT-310-636E
AT-310-636U
AT-310-636L
AT-310-636
AT-310-736
AT-310-836
AT-310-936
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
782
914
672
817
903
963
1,000
1,012
1,068
821
953
1,038
1,106
1,126
1,164
1,216
143-3/4"
3/8"
5-1/4"
2-1/2"
36' 4-1/4"
Weights (LBS)
Shipping
Operating
21,030
21,030
19,380
19,590
19,740
19,890
21,180
20,190
21,330
22,080
22,290
22,440
22,590
21,630
22,890
23,640
2,100
37,650
37,650
36,000
36,210
36,360
36,510
37,800
36,810
37,950
38,700
38,910
39,060
39,210
38,250
39,510
40,260
2,100
Heaviest
SectionF
4,750
4,750
4,200
4,270
4,320
4,370
4,800
4,470
4,850
5,100
5,170
5,220
5,270
4,950
5,370
5,620
700
Fan
Motor (HP)
Air Flow
(CFM)
(3)10
(3)15
(3)10
(3)15
(3)20
(3)25
(3)20
(3)30
(3)25
(3)10
(3)15
(3)20
(3)25
(3)30
(3)30
(3)35
191,200
217,200
194,400
220,800
242,000
260,000
237,700
275,700
255,100
188,100
213,700
234,000
251,300
270,400
265,900
279,100
Dimensions
H
16 5-1/4
16 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
15 5-1/4
16 5-1/4
15 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
1 9-1/2
9 3
9 3
8 3
8 3
8 3
8 3
9 3
8 3
9 3
10 3
10 3
10 3
10 3
9 3
10 3
10 3
1 9-1/2
11 1
11 1
10 1
10 1
10 1
10 1
11 1
10 1
11 1
12 1
12 1
12 1
12 1
11 1
12 1
12 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
67
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS
DOOR
ACCESS
DOOR
7"
ACCESS
DOOR
2"
T
(3) 10 BFW/GROOVED
INLET
108"
H
P
86-1/4"
(3) 10 BFW/GROOVED
OUTLET
25-1/4"
108"
8-1/2"
Model No.
AT-310-154U
AT-310-154L
AT-310-154
AT-310-254L
AT-310-254
AT-310-354U
AT-310-354L
AT-310-354
AT-310-454L
AT-310-454
AT-310-554
AT-310-654
AT-310-754U
AT-310-754L
AT-310-754
AT-310-854
AT-310-954
UT Addition
NOTE:
(1)
(2)
(3)
(4)
5-1/4"
3-5/8"
9' 9-3/4"
207"
16-7/8"
216"
2-1/2"
3/8"
Nominal
Tonnage
859
1,040
1,154
1,080
1,247
988
1,173
1,296
1,246
1,320
1,398
1,481
1,369
1,467
1,552
1,624
1,694
54' 5"
Weights (LBS)
Shipping
Operating
26,910
27,120
27,270
31,080
31,080
28,980
29,190
29,340
27,420
27,720
29,490
29,790
31,230
31,380
31,680
30,540
32,430
2,100
52,130
52,340
52,490
56,300
56,300
54,200
54,410
54,560
52,640
52,940
54,710
55,010
56,450
56,600
56,900
55,760
57,650
2,100
Heaviest
SectionF
5,640
5,710
5,760
7,030
7,030
6,330
6,400
6,450
5,810
5,910
6,500
6,600
7,080
7,130
7,230
6,850
7,480
700
Fan
Motor (HP)
Air Flow
(CFM)
(3)10
(3)15
(3)20
(3)10
(3)15
(3)10
(3)15
(3)20
(3)25
(3)30
(3)25
(3)30
(3)20
(3)25
(3)30
(3)40
(3)40
258,300
293,700
322,300
250,100
284,600
254,400
289,300
317,000
345,700
366,800
340,100
360,000
311,600
334,400
354,300
394,100
387,800
Dimensions
H
15 5-1/4
15 5-1/4
15 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
16 5-1/4
16 5-1/4
15 5-1/4
15 5-1/4
16 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
17 5-1/4
1 9-1/2
8 3
8 3
8 3
10 3
10 3
9 3
9 3
9 3
8 3
8 3
9 3
9 3
10 3
10 3
10 3
9 3
10 3
1 9-1/2
10 0
10 0
10 0
12 0
12 0
11 0
11 0
11 0
10 0
10 0
11 0
11 0
12 0
12 0
12 0
11 0
12 0
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
68
ACCESS DOOR
ACCESS DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
T
2"
71-7/8"
ACCESS
DOOR
(3) 8 BFW/GROOVED
INLET
H
P
86-1/4"
(3) 8 BFW/GROOVED
9"
OUTLET
5-1/4"
25-1/4"
16-7/8"
7-1/4"
3-5/8"
71-7/8"
5-1/4"
143-3/4"
Model No.
AT-312-036U
AT 312-036L
AT 312-036
AT 312-136L
AT 312-136
AT 312-236
AT-312-236M
AT 312-336
AT-312-436U
AT 312-436L
AT 312-436
AT 312-536
AT 312-636
AT 312-736
AT 312-836
AT 312-936
UT Addition
NOTE:
(1)
(2)
(3)
(4)
36' 4-1/4"
851
1,014
1,106
960
1,122
1,187
1,257
1,224
1,021
1,174
1,277
1,316
1,375
1,398
1,458
1,560
Weights (LBS)
Shipping
Operating
21,900
22,110
22,260
23,520
23,730
22,410
22,710
23,880
24,990
25,200
25,350
24,030
25,500
24,330
25,800
26,550
2,100
40,530
40,740
40,890
42,150
42,360
41,040
41,340
42,510
43,620
43,830
43,980
42,660
44,130
42,960
44,430
45,180
2,100
Heaviest
SectionF
4,930
5,000
5,050
5,470
5,540
5,100
5,200
5,590
5,960
6,030
6,080
5,640
6,130
5,740
6,230
6,480
700
Fan
Motor (HP)
Air Flow
(CFM)
(3)10
(3)15
(3)20
(3)10
(3)15
(3)25
(3)30
(3)20
(3)10
(3)15
(3)20
(3)25
(3)25
(3)30
(3)30
(3)40
216,800
246,400
270,400
213,500
242,600
290,000
307,200
265,500
209,900
238,500
261,400
284,700
280,100
301,300
296,400
324,500
Dimensions
H
15 6-1/4
15 6-1/4
15 6-1/4
16 6-1/4
16 6-1/4
15 6-1/4
15 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
1 9-1/2
8 4
8 4
8 4
9 4
9 4
8 4
8 4
9 4
10 4
10 4
10 4
9 4
10 4
9 4
10 4
10 4
1 9-1/2
10 2
10 2
10 2
11 2
11 2
10 2
10 2
11 2
12 2
12 2
12 2
11 2
12 2
11 2
12 2
12 2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
69
2-1/2"
3/8"
Nominal
Tonnage
134-3/4"
11' 10"
ACCESS DOOR
ACCESS DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
T
2"
83-7/8"
ACCESS
DOOR
(3) 10 BFW/GROOVED
INLET
H
P
98-1/4"
(3) 10 BFW/GROOVED
9
OUTLET
5-1/4"
25-1/4"
16-7/8"
8-1/2"
3-5/8"
83-7/8"
158-3/4"
5-1/4"
167-3/4"
11' 10"
Model No.
AT-312-042L
AT-312-042
AT-312-142E
AT-312-142U
AT-312-142L
AT-312-142
AT-312-142M
AT-312-242L
AT-312-242
AT-312-342
AT-312-442
AT-312-542L
AT-312-542
AT-312-642
AT-312-742
AT-312-842
AT-312-942
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,045
1,229
910
1,091
1,195
1,289
1,366
1,123
1,293
1,330
1,428
1,395
1,495
1,519
1,589
1,662
1,738
2-1/2"
42' 4-1/4"
3/8"
Weights (LBS)
Shipping
Operating
26,580
26,790
24,600
24,810
24,990
25,170
25,380
28,140
28,350
26,970
27,150
28,530
28,710
27,360
28,920
28,140
29,700
2,100
48,570
48,780
46,590
46,800
46,980
47,160
47,370
50,130
50,340
48,960
49,140
50,520
50,700
49,350
50,910
50,130
51,690
2,100
Heaviest
SectionF
6,020
6,090
5,360
5,430
5,490
5,550
5,620
6,540
6,610
6,150
6,210
6,670
6,730
6,280
6,800
6,540
7,060
700
Fan
Motor (HP)
Air Flow
(CFM)
(3)10
(3)15
(3)10
(3)15
(3)20
(3)25
(3)30
(3)10
(3)15
(3)20
(3)25
(3)20
(3)25
(3)30
(3)30
(3)40
(3)40
231,900
263,400
235,500
267,800
293,600
315,200
334,000
227,900
259,100
288,500
309,500
284,000
304,600
327,600
322,400
359,100
352,800
Dimensions
H
17 6-1/4
17 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
1 9-1/2
9 4
9 4
8 4
8 4
8 4
8 4
8 4
10 4
10 4
9 4
9 4
10 4
10 4
9 4
10 4
9 4
10 4
1 9-1/2
12 1
12 1
11 1
11 1
11 1
11 1
11 1
13 1
13 1
12 1
12 1
13 1
13 1
12 1
13 1
12 1
13 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
70
ACCESS DOOR
ACCESS DOOR
7"
ACCESS
DOOR
T
2"
ACCESS
DOOR
108"
ACCESS
DOOR
(3) 10 BFW/GROOVED
INLET
H
P
98-1/4"
(3) 10 BFW/GROOVED
OUTLET
5-1/4"
25-1/4"
9"
16-7/8"
8-1/2"
3-5/8"
Model No.
108"
207"
5-1/4"
AT-312-054E
AT-312-054U
AT-312-054L
AT-312-054
AT-312-154U
AT-312-154L
AT-312-154
AT-312-254
AT-312-354
AT-312-454E
AT-312-454U
AT-312-454L
AT-312-454
AT-312-554
AT-312-654
AT-312-754
AT-312-854
AT-312-954
UT Addition
NOTE:
(1)
(2)
(3)
(4)
54' 5"
1,324
1,499
1,586
1,670
1,473
1,648
1,752
1,840
1,851
1,560
1,725
1,828
1,935
2,036
2,124
2,182
2,281
2,367
Weights (LBS)
Shipping
Operating
31,620
31,800
31,950
32,280
33,960
34,140
34,290
33,060
34,620
36,180
36,360
36,510
36,840
35,400
37,620
35,580
37,800
38,130
3,600
59,430
59,610
59,760
60,090
61,770
61,950
62,100
60,870
62,430
63,990
64,170
64,320
64,650
63,210
65,430
63,390
65,610
65,940
3,600
Heaviest
SectionF
6,700
6,760
6,810
6,920
7,480
7,540
7,590
7,180
7,700
8,220
8,280
8,330
8,440
7,960
8,700
8,020
8,760
8,870
1,200
Fan
Motor (HP)
Air Flow
(CFM)
(3)15
(3)20
(3)25
(3)30
(3)15
(3)20
(3)25
(3)40
(3)30
(3)15
(3)20
(3)25
(3)30
(3)40
(3)40
(3)50
(3)50
(3)60
330,500
362,000
389,000
412,300
325,600
356,200
382,300
451,700
405,300
320,200
350,500
376,300
398,900
443,500
436,200
475,900
467,400
495,100
Dimensions
H
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2
8 4
8 4
8 4
8 4
9 4
9 4
9 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
10 4
9 4
10 4
10 4
1 3-1/2
11 1
11 1
11 1
11 1
12 1
12 1
12 1
11 1
12 1
13 1
13 1
13 1
13 1
12 1
13 1
12 1
13 1
13 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
71
2-1/2"
3/8"
Nominal
Tonnage
216"
11' 10"
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
7"
ACCESS
DOOR
T
2"
ACCESS
DOOR
ACCESS
DOOR
(3) 10 BFW/GROOVED
INLET
120"
H
P
98-1/4"
(3) 10 BFW/GROOVED
OUTLET
25-1/4"
120"
231"
16-7/8"
8-1/2"
5-1/4"
3-5/8"
11' 10"
Model No.
AT-312-160
AT-312-260L
AT-312-260
AT-312-360L
AT-312-360
AT-312-460E
AT-312-460U
AT-312-460L
AT-312-460
AT-312-560L
AT-312-560
AT-312-660L
AT-312-660
AT-312-760
AT-312-860
AT-312-960
UT Addition
NOTE:
(1)
(2)
(3)
(4)
240"
2-1/2"
3/8"
Nominal
Tonnage
1,368
1,600
1,745
1,707
1,844
1,508
1,622
1,865
2,023
1,859
2,083
1,955
2,174
2,260
2,352
2,440
60' 5"
Weights (LBS)
Shipping
Operating
33,960
36,150
36,300
38,850
39,000
34,110
34,440
35,220
35,400
36,630
37,410
39,330
40,110
37,590
40,290
40,620
3,600
65,160
67,350
67,500
70,050
70,200
65,310
65,640
66,420
66,600
67,830
68,610
70,530
71,310
68,790
71,490
71,820
3,600
Heaviest
SectionF
7,210
7,940
7,990
8,840
8,890
7,260
7,370
7,630
7,690
8,100
8,360
9,000
9,260
8,420
9,320
9,430
1,200
Fan
Motor (HP)
Air Flow
(CFM)
(3)20
(3)20
(3)25
(3)20
(3)25
(3)25
(3)30
(3)40
(3)50
(3)30
(3)40
(3)30
(3)40
(3)50
(3)50
(3)60
369,800
363,700
390,100
357,600
383,700
396,900
420,600
460,000
493,600
413,000
451,400
406,400
444,400
484,000
476,100
504,600
Dimensions
H
16 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2
8 4
9 4
9 4
10 4
10 4
8 4
8 4
8 4
8 4
9 4
9 4
10 4
10 4
9 4
10 4
10 4
1 3-1/2
11 1
12 1
12 1
13 1
13 1
11 1
11 1
11 1
11 1
12 1
12 1
13 1
13 1
12 1
13 1
13 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
72
ACCESS
DOOR
ACCESS
DOOR
7"
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
(3) 14 BFW/GROOVED
INLET
142-1/2"
2"
H
P
99-3/8"
(3) 14 BFW/GROOVED
OUTLET
26"
142-1/2"
Model No.
AT-314-0172U
AT-314-0172L
AT-314-0172
AT-314-0272
AT-314-0372
AT-314-0472L
AT-314-0472
AT-314-0572
AT-314-0672E
AT-314-0672U
AT-314-0672L
AT-314-0672
AT-314-0772
AT-314-0872
AT-314-0972
AT-314-1072
AT-314-1172
AT-314-1272
UT Addition
NOTE:
(1)
(2)
(3)
(4)
3/8"
Nominal
Tonnage
1,789
1,986
2,095
2,271
2,439
2,255
2,437
2,551
2,056
2,257
2,364
2,601
2,773
2,770
2,919
2,944
3,091
3,322
285"
4-1/8"
(3) 4 FPT
DRAIN
2-1/2"
71' 8"
Weights (LBS)
Shipping
Operating
53,340
53,490
53,550
54,000
55,050
59,580
59,730
59,790
56,460
56,610
56,670
57,120
58,170
60,240
61,290
58,680
61,800
62,520
3,750
100,890
101,040
101,100
101,550
102,600
107,130
107,280
107,340
104,010
104,160
104,220
104,670
105,720
107,790
108,840
106,230
109,350
110,070
3,750
Heaviest
SectionF
10,600
10,650
10,670
10,820
11,170
12,680
12,730
12,750
11,640
11,690
11,710
11,860
12,210
12,900
13,250
12,380
13,420
13,660
1,250
Fan
Motor (HP)
Air Flow
(CFM)
(3)20
(3)25
(3)30
(3)40
(3)50
(3)20
(3)25
(3)30
(3)20
(3)25
(3)30
(3)40
(3)50
(3)40
(3)50
(3)60
(3)60
(3)75
467,000
499,900
530,100
580,900
624,200
447,100
479,800
509,800
460,000
493,500
521,300
570,700
613,000
561,200
602,700
648,600
638,300
699,700
Dimensions
H
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
73
(3) 4 FPT
OVERFLOW
276"
9"
13' 11-1/4"
9"
72-1/4"
212-3/4"
17-3/8"
(3) 3 MPT
MAKE-UP
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
7"
ACCESS
DOOR
2"
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
T
(3) 14 BFW/GROOVED
INLET
154-1/2"
H
P
123-3/8"
26"
154-1/2"
17-3/8"
230-5/8"
9"
4-1/8"
Model No.
AT-314-578
AT-314-678
AT-314-778
AT-314-878
AT-314-978
UT Addition
NOTE:
(1)
(2)
(3)
(4)
299-7/8"
308-7/8"
13' 11-1/4"
(3) 14 BFW/GROOVED
OUTLET
(3) 4 FPT
OVERFLOW
2-1/2"
3/8"
77' 7-5/8"
Nominal
Tonnage
2,936
3,157
3,344
3,655
3,908
Weights (LBS)
Shipping
Operating
73,620
73,800
74,100
75,060
75,120
D
124,110
124,290
124,590
125,550
125,610
7,200
Heaviest
SectionF
17,660
17,720
17,820
18,140
18,160
D
Fan
Motor (HP)
Air Flow
(CFM)
(6)20
(6)25
(6)30
(6)40
(6)50
586,300
628,800
665,700
728,100
780,300
Dimensions
H
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2
12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
74
173-1/2" 154-1/2"
135-1/2"
83-5/8"
143"
256"
315-3/8"
428-3/8"
487-3/4"
42' 8"
7"
(2) ACCESS
DOOR
(2) ACCESS
DOOR
(2) ACCESS
DOOR
123-3/8"
26"
17-3/8"
4"
25' 8-7/8"
157-1/4"
161-1/2"
162-1/2"
167-1/4"
1- 3/8"
5-1/8"
42' 8"
Model No.
AT-342-526
AT-342-626
AT-342-726
AT-342-826
AT-342-926
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal Tonnage
2,882
3,100
3,286
3,593
3,844
Weights (LBS)
Shipping
Operating
73,410
73,590
73,890
74,850
74,910
D
123,900
124,080
124,380
125,340
125,400
7,200
17,660
17,720
17,820
18,140
18,160
D
Fan
Air Flow (CFM)
Motor (HP)
(6)20
(6)25
(6)30
(6)40
(6)50
560,606
601,334
636,679
696,431
746,358
Dimensions
H
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2
12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
75
Heaviest
SectionF
7"
ACCESS
DOOR
ACCESS DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
2"
58-7/8"
(4) 8 BFW/GROOVED
INLET
ACCESS DOOR
ACCESS DOOR
2"
P
98-1/4"
(2) 12 BFW/GROOVED
OUTLET
(2) 3 MPT
OVERFLOW
25-1/4"
(2) 2 MPT
MAKE-UP
93-5/8"
(2) 3 MPT
DRAIN
16-7/8"
108-3/4"
9-1/2"
112-1/2"
3-5/8"
113-1/2"
117-3/4"
5-1/8
20' 5/8"
Model No.
AT-420-124L
AT-420-124
AT-420-224E
AT-420-224U
AT-420-224L
AT-420-224
AT-420-324
AT-420-424
AT-420-524
AT-420-624E
AT-420-624U
AT-420-624L
AT-420-624
AT-420-724
AT-420-824
AT-420-924
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,051
1,229
904
1,098
1,214
1,295
1,344
1,361
1,435
1,103
1,281
1,394
1,485
1,513
1,563
1,632
1-3/8"
Weights (LBS)
Shipping
Operating
27,420
27,700
25,500
25,780
25,980
26,180
27,900
26,580
28,100
29,100
29,380
29,580
29,780
28,500
30,180
31,180
D
49,560
49,840
47,640
47,920
48,120
48,320
50,040
48,720
50,240
51,240
51,520
51,720
51,920
50,640
52,320
53,320
2,800
Heaviest
SectionF
U 4,680
U 4,750
L 4,350
L 4,350
L 4,350
U 4,370
U 4,800
U 4,470
U 4,850
U 5,100
U 5,170
U 5,250
U 5,270
U 4,950
U 5,370
U 5,620
D
24' 1-3/4"
Fan
Air Flow (CFM)
Motor (HP)
(4)10
(4)15
(4)10
(4)15
(4)20
(4)25
(4)20
(4)30
(4)25
(4)10
(4)15
(4)20
(4)25
(4)30
(4)30
(4)35
252,300
286,500
256,500
291,400
319,200
343,000
313,600
363,600
336,500
248,200
281,900
308,700
331,400
356,600
350,900
368,000
Dimensions
H
17 5 1/4
17 5 1/4
16 5 1/4
16 5 1/4
16 5 1/4
16 5 1/4
17 5 1/4
16 5 1/4
17 5 1/4
18 5 1/4
18 5 1/4
18 5 1/4
18 5 1/4
17 5 1/4
18 5 1/4
18 5 1/4
1 9-1/2
9 3
9 3
9 3
9 3
9 3
9 3
8 3
9 3
8 3
10 3
10 3
10 3
10 3
8 3
10 3
10 3
1 9-1/2
12 1
12 1
11 1
11 1
11 1
11 1
12 1
11 1
12 1
13 1
13 1
13 1
13 1
12 1
13 1
13 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
76
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
7"
(4) 10 BFW/GROOVED
INLET
58-7/8"
(4) 10 BFW/GROOVED
OUTLET
5-1/8"
117-3/4"
98-1/4"
8-1/2"
3-5/8"
AT-420-136U
AT-420-136L
AT-420-136
AT-420-236L
AT-420-236
AT-420-336U
AT-420-336L
AT-420-336
AT-420-436L
AT-420-436
AT-420-536
AT-420-636
AT-420-736U
AT-420-736L
AT-420-736
AT-420-836
AT-420-936
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,111
1,348
1,496
1,408
1,626
1,281
1,522
1,686
1,618
1,713
1,820
1,928
1,786
1,914
2,025
2,116
2,212
Weights (LBS)
Shipping
Operating
35,300
35,580
35,780
40,860
40,860
38,060
38,340
38,540
35,980
36,380
38,740
39,140
41,060
41,260
41,660
40,140
42,660
D
69,260
69,540
69,740
74,820
74,820
72,020
72,300
72,500
69,940
70,340
72,700
73,100
75,020
75,220
75,620
74,100
76,620
2,800
Heaviest
SectionF
L6,370
L 6,370
L 6,370
U 7,030
U 7,030
L 6,370
U 6,400
U 6,450
L 6,370
L 6,370
U 6,500
U 6,600
U 7,080
U 7,130
U 7,230
U 6,850
U 7,480
D
Fan
Air Flow (CFM)
Motor (HP)
(4)10
(4)15
(4)20
(4)10
(4)15
(4)10
(4)15
(4)20
(4)25
(4)30
(4)25
(4)30
(4)20
(4)25
(4)30
(4)40
(4)40
330,400
375,800
412,300
319,900
364,200
325,400
370,200
405,800
442,400
469,300
435,200
460,900
398,700
427,900
453,400
504,500
496,200
1-3/8"
Dimensions
H
16 5-1/4
16 5-1/4
16 5-1/4
18 5-1/4
18 5-1/4
17 5-1/4
17 5-1/4
17 5-1/4
16 5-1/4
16 5-1/4
17 5-1/4
17 5-1/4
18 5-1/4
18 5-1/4
18 5-1/4
17 5-1/4
18 5-1/4
1 9-1/2
9 3
9 3
9 3
10 3
10 3
8 3
8 3
8 3
9 3
9 3
8 3
8 3
10 3
10 3
10 3
8 3
10 3
1 9-1/2
11
11
11
13
13
12
12
12
11
11
12
12
13
13
13
12
13
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
77
36' 2-1/2"
1-3/8"
20' 5/8"
Model No.
2"
16-7/8"
112-1/2"
113-1/2"
ACCESS
DOOR
25-1/4"
93-5/8"
108-3/4"
(4) 3 MPT
DRAIN
ACCESS
DOOR
ACCESS
DOOR
2"
(4) 2 MPT
MAKE-UP
(4) 3 MPT
OVERFLOW
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
(4) 8 BFW/GROOVED
OUTLET
71"
7"
P
ACCESS
DOOR
(2) 12 BFW/GROOVED
OUTLET
9-1/2"
133"
ACCESS
DOOR
3-5/8"
136-3/4"
ACCESS
DOOR
2"
25-1/4"
16-7/8"
117-7/8"
ACCESS
DOOR
137-3/4"
5-1/8"
142"
98-1/4"
24' 1-1/8"
1-3/8"
Model No.
AT-424-024L
AT-424-024
AT-424-124
AT-424-224L
AT-424-224
AT-424-324
AT-424-424
AT-424-524
AT-424-624U
AT-424-624L
AT-424-624
AT-424-724
AT-424-824
AT-424-924U
AT-424-924L
AT-424-924
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,114
1,327
1,449
1,257
1,471
1,555
1,605
1,647
1,340
1,524
1,678
1,727
1,835
1,807
1,916
2,050
Weights (LBS)
Shipping
Operating
29,480
30,040
30,240
31,640
32,200
30,440
32,400
30,840
33,600
34,160
34,360
32,600
33,000
34,560
34,960
35,960
D
54,340
54,900
55,100
56,500
57,060
55,300
57,260
55,700
58,460
59,020
59,220
57,460
57,860
59,420
59,820
60,820
4,800
Heaviest
SectionF
L 5,020
L 5,020
U 5,050
U 5,400
U 5,540
U 5,100
U 5,590
U 5,200
U 5,890
U 6,030
U 6,080
U 5,640
U 5,740
U 6,130
U 6,230
U 6,480
D
24' 1-3/4"
Fan
Air Flow (CFM)
Motor (HP)
(4)10
(4)15
(4)20
(4)10
(4)15
(4)25
(4)20
(4)30
(4)10
(4)15
(4)20
(4)25
(4)30
(4)25
(4)30
(4)40
283,500
322,300
353,400
279,200
317,000
379,400
347,400
401,900
274,500
312,000
341,900
372,500
394,400
366,200
387,500
424,600
Dimensions
H
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
17 6-1/4
16 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 9-1/2
8 4
8 4
8 4
9 4
9 4
8 4
9 4
8 4
10 4
10 4
10 4
9 4
9 4
10 4
10 4
10 4
1 9-1/2
11 2
11 2
11 2
12 2
12 2
11 2
12 2
11 2
13 2
13 2
12 2
12 2
13 2
13 2
13 2
13 2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
78
ACCESS
DOOR
71"
(4) 10 BFW/GROOVED
OUTLET
7"
(4) 10 BFW/GROOVED
OUTLET
117-7/8"
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
3-5/8"
136-3/4"
2"
137-3/4"
5-1/8"
ACCESS
DOOR
25-1/4"
16-7/8"
8-1/2"
133"
ACCESS
DOOR
142"
24' 1-1/8"
98-1/4"
1- 3/8"
Model No.
AT-424-028U
AT-424-028L
AT-424-028
AT-424-128L
AT-424-128
AT-424-228
AT-424-228M
AT-424-328U
AT-424-328L
AT-424-328
AT-424-428
AT-424-528
AT-424-628
AT-424-728
AT-424-728M
AT-424-828
AT-424-928
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,159
1,405
1,564
1,434
1,654
1,689
1,838
1,322
1,563
1,745
1,833
1,873
1,965
1,993
2,199
2,088
2,283
Weights (LBS)
Shipping
Operating
32,680
33,240
33,480
37,400
37,960
33,720
34,000
35,320
35,880
36,120
38,200
36,360
38,440
36,640
37,680
38,720
39,760
D
62,140
62,700
62,940
66,860
67,420
63,180
63,460
64,780
65,340
65,580
67,660
65,820
67,900
66,100
67,140
68,180
69,220
4,800
L 5,760
L 5,760
L 5,760
U 6,470
U 6,610
L 5,760
L 5,760
U 5,950
U 6,090
U 6,150
U 6,670
U 6,210
U 6,730
U 6,280
U 6,540
U 6,800
U 7,060
D
Fan
Air Flow (CFM)
Motor (HP)
(4)10
(4)15
(4)20
(4)10
(4)15
(4)25
(4)30
(4)10
(4)15
(4)20
(4)20
(4)25
(4)25
(4)30
(4)40
(4)30
(4)40
299,400
340,300
372,900
289,800
329,600
400,300
423,700
294,900
335,100
366,600
360,700
393,600
387,300
416,200
455,600
409,900
448,300
Dimensions
H
16 6-1/4
16 6-1/4
16 6-1/4
18 6-1/4
18 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
17 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
1 9-1/2
8 4
8 4
8 4
10 4
10 4
8 4
8 4
9 4
9 4
9 4
10 4
9 4
10 4
9 4
9 4
10 4
10 4
1 9-1/2
11 1
11 1
11 1
13 1
13 1
11 1
11 1
12 1
12 1
12 1
13 1
12 1
13 1
12 1
13 1
13 1
13 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
79
Heaviest
SectionF
1- 3/8"
28' 1-3/4"
ACCESS
DOOR
71"
(4) 10 BFW/GROOVED
INLET
P
7"
(4) 10 BFW/GROOVED
OUTLET
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
2"
3-5/8"
136-3/4"
137-3/4"
5-1/8"
ACCESS DOOR
8-1/2"
133"
ACCESS
DOOR
25-1/4"
16-7/8"
117-7/8"
ACCESS DOOR
142"
24' 1-1/8"
98-1/4"
1- 3/8"
Model No.
AT-424-036L
AT-424-036
AT-424-136
AT-424-236U
AT-424-236L
AT-424-236
AT-424-336L
AT-424-336
AT-424-436
AT-424-536E
AT-424-536U
AT-424-536L
AT-424-536
AT-424-636
AT-424-736
AT-424-836L
AT-424-836
AT-424-936
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,687
1,914
2,023
1,883
2,108
2,246
2,133
2,350
2,373
2,005
2,221
2,353
2,491
2,614
2,806
2,736
2,938
3,049
Weights (LBS)
Shipping
Operating
41,760
42,000
42,200
44,880
45,120
45,320
42,640
43,680
45,760
47,840
48,080
48,280
48,720
46,800
46,800
49,760
50,000
50,440
D
79,040
79,280
79,480
82,160
82,400
82,600
79,920
80,960
83,040
85,120
85,360
85,560
86,000
84,080
84,320
87,040
87,280
87,720
4,800
Heaviest
SectionF
L 7,480
L 7,480
L 7,480
U 7,480
U 7,540
U 7,590
L 7,480
L 7,480
U 7,700
U 8,220
U 8,280
U 8,330
U 8,440
U 7,960
U 8,020
U 8,700
U 8,760
U 8,870
D
1- 3/8"
36' 2-1/4"
Fan
Air Flow (CFM)
Motor (HP)
(4)15
(4)20
(4)25
(4)15
(4)20
(4)25
(4)30
(4)40
(4)30
(4)15
(4)20
(4)25
(4)30
(4)40
(4)50
(4)40
(4)50
(4)60
423,100
463,300
498,000
416,900
456,200
489,600
527,900
578,400
519,200
409,800
448,800
481,900
510,800
567,900
609,200
558,300
598,800
634,500
Dimensions
H
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2
8 4
8 4
8 4
9 4
9 4
9 4
8 4
8 4
9 4
10 4
10 4
10 4
10 4
9 4
9 4
10 4
10 4
10 4
1 3-1/2
11 1
11 1
11 1
12 1
12 1
12 1
11 1
11 1
12 1
13 1
13 1
13 1
13 1
12 1
12 1
13 1
13 1
13 1
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
80
ACCESS DOOR
AC CE SS DO O R
ACC ES S DO OR
7"
2"
T
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
71"
(4) 10 BFW/GROOVED
INLET
H
P
98-1/4"
(4) 12 BFW/GROOVED
OUTLET
25-1/4"
117-7/8"
133"
9-1/2"
136-3/4"
16-7/8"
3-5/8"
137-3/4"
5-1/8"
142"
1-3/8"
24'-1-1/8"
Model No.
AT-424-0140
AT-424-0240
AT-424-0340
AT-424-0440
AT-424-0540
AT-424-0640
AT-424-0740
AT-424-0840
AT-424-0940
AT-424-1040
AT-424-1140
AT-424-1240
AT-424-1340
AT-424-1440
AT-424-1540
AT-424-1640
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
1,733
1,919
2,064
2,379
2,584
2,038
2,230
2,380
2,670
2,900
2,190
2,369
2,515
2,798
3,028
3,141
Weights (LBS)
Shipping
Operating
44,640
44,840
45,280
46,320
46,560
47,560
47,760
48,200
49,240
49,480
51,160
51,360
51,800
52,840
53,080
53,520
D
86,420
86,620
87,060
88,100
88,340
89,340
89,540
89,980
91,020
91,260
92,940
93,140
93,580
94,620
94,860
95,300
4,800
L 7,900
L 7,900
L 7,900
L 7,900
L 7,900
U 7,940
U 7,990
U 8,100
U 8,360
U 8,420
U 8,840
U 8,890
U 9,000
U 9,260
U 9,320
U 9,430
D
Fan
Air Flow (CFM)
Motor (HP)
(4)20
(4)25
(4)30
(4)40
(4)50
(4)20
(4)25
(4)30
(4)40
(4)50
(4)20
(4)25
(4)30
(4)40
(4)50
(4)60
472,200
506,800
537,000
587,500
630,400
464,500
498,300
527,600
576,800
618,200
456,500
489,900
519,000
567,600
608,300
644,800
1-3/8"
Dimensions
H
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
16 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
17 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
18 6-1/4
1 3-1/2
8 4
8 4
8 4
8 4
8 4
9 4
9 4
9 4
9 4
9 4
10 4
10 4
10 4
10 4
10 4
10 4
11 1
11 1
11 1
11 1
11 1
12 1
12 1
12 1
12 1
12 1
13 11
13 11
13 11
13 11
13 11
13 11
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
81
Heaviest
SectionF
40'-2-1/4"
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
7"
ACCESS DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
ACCESS
DOOR
(4) 14 BFW/GROOVED
INLET
142-1/2"
2"
H
P
99-3/8"
26"
(4) 14 BFW/GOOVED
OUTLET
138"
157-3/8"
9"
4-1/8"
161-5/8"
162-1/8"
5-1/8"
285"
AT-428-0148U
AT-428-0148L
AT-428-0148
AT-428-0248
AT-428-0348
AT-428-0448L
AT-428-0448
AT-428-0548
AT-428-0648E
AT-428-0648U
AT-428-0648L
AT-428-0648
AT-428-0748
AT-428-0848
AT-428-0948
AT-428-1048
AT-428-1148
AT-428-1248
AT-428-1348*
UT Addition
NOTE:
(1)
(2)
(3)
(4)
51' 1"
1- 3/8"
28' 3-5/8"
Model No.
43"
167-1/4"
Weights (LBS)
Nominal
Tonnage
Shipping
Operating
2,231
2,482
2,626
2,846
3,067
2,858
3,093
3,237
2,585
2,837
2,984
3,283
3,509
3,524
3,714
3,728
3,933
4,229
4,475
65,280
65,480
65,560
66,160
67,560
73,600
73,800
73,880
69,440
69,640
69,720
70,320
71,720
74,480
75,880
72,400
76,560
77,520
79,820
128,680
128,880
128,960
129,560
130,960
137,000
137,200
137,280
132,840
133,040
133,120
133,720
135,120
137,880
139,280
135,800
139,960
140,920
142,680
5,000
Heaviest
SectionF
10,600
10,650
10,670
10,820
11,170
12,680
12,730
12,750
11,640
11,690
11,710
11,860
12,210
12,900
13,250
12,380
13,420
13,660
14,100
1,250
Fan
Air Flow (CFM)
Motor (HP)
(4)20
(4)25
(4)30
(4)40
(4)50
(4)20
(4)25
(4)30
(4)20
(4)25
(4)30
(4)40
(4)50
(4)40
(4)50
(4)60
(4)60
(4)75
(4)100
595,300
646,400
685,500
752,000
807,000
578,700
621,100
660,100
586,200
629,300
675,000
739,200
793,000
726,500
780,200
840,300
826,200
904,900
970,300
1- 3/8"
Dimensions
H
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
17 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
18 5-5/8
19 5-5/8
19 5-5/8
19 5-5/8
1 1-1/2
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
9 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
10 2-1/4
11 2-1/4
11 2-1/4
11 2-1/4
1 1-1/2
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
11 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
12 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
13 3-7/8
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
82
7"
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS DOOR
ACCESS
DOORS
ACCESS
DOORS
ACCESS
DOORS
ACCESS
DOORS
T
(4) 14 BFW/GROOVED
INLET
2"
83-5/8"
H
P
123-3/8"
(2) 14 BFW/GROOVED
OUTLET
5-1/8"
26"
17-3/8"
138"
157-1/4"
161-1/2"
AT-428-552
AT-428-652
AT-428-752
AT-428-852
AT-428-952
UT Addition
NOTE:
(1)
(2)
(3)
(4)
Nominal
Tonnage
3,857
4,148
4,395
4,806
5,141
9"
4"
1-3/8"
Weights (LBS)
Shipping
Operating
97,960
98,200
98,600
99,880
99,960
D
165,280
165,520
165,920
167,200
167,280
9,600
Heaviest
SectionF
17,660
17,720
17,820
18,140
18,160
D
55' 3/4"
Fan
Air Flow (CFM)
Motor (HP)
(8)20
(8)25
(8)30
(8)40
(8)50
747,500
801,900
849,100
928,900
995,700
1-3/8"
Dimensions
H
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
1 3-1/2
12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
16 3-3/4
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
83
43"
162-1/2"
167-1/4"
28' 3-5/8"
Model No.
308-7/8"
25'-8 7/8"
173-1/2" 154-1/2"
135-1/2"
83-5/8"
83-5/8"
143"
143"
196-5/8"
196-5/8"
256"
256"
57' 3/8"
7"
(2) ACCESS
DOOR
(2) ACCESS
DOOR
(2) ACCESS
DOOR
(2) ACCESS
DOOR
H
123-3/8"
26"
17-3/8"
4"
161-1/2"
162-1/2"
1-3/8"
25' 8-7/8"
157-1/4"
167-1/4"
5-1/8"
57' 3/8"
Weights (LBS)
Model No.
Nominal
Tonnage
Shipping
Operating
Heaviest SectionF
AT-456-526
AT-456-626
AT-456-726
AT-456-826
AT-456-926
3,802
4,090
4,335
4,743
5,075
97,880
98,120
98,520
99,800
99,880
165,200
165,440
165,840
167,120
167,200
17,660
17,720
17,820
18,140
18,160
9,600
UT Addition
NOTE:
(1)
(2)
(3)
(4)
FanMotor (HP)
(8)20
(8)25
(8)30
(8)40
(8)50
711,215
762,926
807,791
883,646
947,043
Dimensions
H
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
22 3-1/2
12 1/8
12 1/8
12 1/8
12 1/8
12 1/8
1 3-1/2
An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water.
Do not use catalog drawings for certified prints. Dimensions and weights are subject to change.
Adequate spacing must be allowed for access to the cooling tower. Refer to EVAPCOs Equipment Layout Manual.
Nominal Tonnage is based on 3 gpm per ton at 95 degree entering water temperature, 85 degree leaving water temperature, and 78 degree wet-bulb temperature.
84
14-64 to14-94
14-66 to 14-96
14-69 to 14-99
14-612 to 14-912
19-56 to 19-96
19-28 to 19-98
19-59 to 19-99
19-111 to 19-911
19-412 to 19-912
19-114 to 19-914
270
320
395
460
525
610
110-112 to 110-912
110-118 to 110-918
645
980
112-012 to 112-912
112-314 to 112-914
720
855
112-018 to 112-918
112-520 to 112-920
1090
1210
114-0124 to114-1324
114-526 to 114-926
1855
2085
1-CELL
Model No.
85
2-CELL
3-CELL
26-517 to 26-917
28-217 to 28-917
640
Model No.
4-CELL
The following chart provides the maximum drain down volume allowable per AT/UT/USS model number. Use this chart
when sizing indoor or outdoor remote sumps tanks. Remote
sump applications are commonly used whenever a cooling
tower is idle during sub-freezing weather to protect the water
in the basin from freezing or for large multi-tower industrial
applications. Either application allows the circulating water to
gravity drain into a remote sump tank indoors or a large, outdoor concrete basin located underneath the cooling tower.
212-59 to 212-99
540
215-29 to 215-99
640
217-59 to 217-99
217-111 to 217-911
217-412 to 217-912
217-214 to 217-914
790
920
1050
1220
29-318 to 29-918
29-121 to 29-921
29-024 to 29-924
29-228 to 29-928
790
920
1050
1220
210-124 to 210-924
210-136 to 210-936
1290
1960
212-024 to 212-924
212-128 to 212-928
212-036 to 212-936
212-0140 to 212-1640
1440
1710
2180
2420
214-0148 to214-1248
214-552 to 214-952
3710
4170
220-112 to 220-912
220-118 to 220-918
1290
1960
224-018 to 224-918
224-720 to 224-920
2180
2420
228-0124 to 228-1024
228-526 to 228-926
3710
4170
39-336 to 39-936
39-242 to 39-942
1575
1830
310-136 to 310-936
310-154 to 310-954
1935
2940
312-036 to 312-936
312-042 to 312-942
312-054 to 312-954
312-260 to 312-960
2160
2565
3270
3630
314-0172 to 314-1272
314-578 to 314-978
342-526 to 342-926
5565
6255
6255
420-124 to 420-924
420-136 to 420-936
2580
3920
424-024 to 424-924
424-028 to 424-928
424-036 to 424-936
424-0140 to 424-1640
2880
3420
4360
4840
428-0148 to 428-1348
428-552 to 428-952
456-526 to 456-926
7420
8340
8340
Applications
Design
EVAPCO Cooling towers are of heavy-duty construction and designed for
long trouble-free operation. Proper equipment selection, installation and
maintenance are necessary to ensure full unit performance while maximizing the equipments service life. Some of the major considerations in the
application of a tower are presented below. For additional information, please
contact the factory.
Piping
Cooling tower piping should be designed and installed in accordance with
generally accepted engineering practices. All piping should be anchored by
properly designed hangers and supports with allowance made for possible
expansion and contraction. No external loads should be placed upon cooling tower connections, nor should any of the piping supports be anchored to
the unit framework.
The piping connection locations shown on the drawings included in this
catalog and on the website are standard locations that can be changed. If
the piping connection locations shown do not meet the needs of a particular
project, contact the factory to determine a viable solution.
Air Circulation
In reviewing the system design and unit location, it is important that enough
fresh air is provided to enable proper unit performance. The best location
is on an unobstructed roof top or at ground level away from walls and other
barriers. Care must be taken when locating towers in wells or enclosures or
next to high walls. The potential for recirculation of the hot, moist discharge
air back into the fan intake exists. Recirculation raises the wetbulb temperature of the entering air, causing the leaving water temperature to rise above
the design conditions. For these cases, the overall unit height should be
raised so it is even with the adjacent wall, reducing the chance of recirculation. This can be done by raising the entire unit or adding a discharge hood.
For additional information, see the EVAPCO Equipment Layout Manual.
Engineering Assistance is also available from the factory to identify potential
recirculation problems and recommend solutions, such as re-orienting multicell units.
Design Flexibility and Assistance
The large number of EVAPCO AT Cooling towers makes it easy to find a
model to meet your design and layout needs. If there is an application for
which the standard catalog product line does not work, EVAPCO will make a
cooling tower that will fit your requirement. Consult your local EVAPCO Representative or the factory for assistance with Applications, Layout, Accessories
or other design needs.
Water Treatment
Proper water treatment is an essential part of the maintenance required
for all evaporative cooling equipment. A well designed and consistently
implemented water treatment program will help to ensure efficient system
operation while maximizing the equipments service life. A qualified water
treatment company should design a site specific water treatment protocol
based on equipment (including all metallurgies in the cooling system), location, makeup water quality and usage.
86
Plan View
End Elevation
2-CELL
Dimensions
L
14-64 to14-94
4 0-15/32
3 11-5/8
14-66 to 14-96
4 0-15/32
5 11-5/8
Model No.
2-CELL
Dimensions
W
29-121 to 29-921
8 5-1/2
21 0
29-024 to 29-924
8 5-1/2
24 2
14-69 to 14-99
4 0-15/32
8 11-11/16
29-228 to 29-928
8 5-1/2
28 2
14-612 to 14-912
4 0-15/32
11 11-5/8
210-124 to 210-924
9 9-3/4
24 2
19-56 to 19-96
5 11-7/8
8 5-1/2
210-136 to 210-936
9 9-3/4
36 2-1/2
19-28 to 19-98
7 5-7/8
8 5-1/2
212-024 to 212-924
11 10
24 2
19-59 to 19-99
8 5-1/2
8 11-1/2
212-128 to 212-928
11 10
28 2
19-111 to 19-911
8 5-1/2
10 5-1/2
212-036 to 212-936
11 10
36 2-1/2
19-412 to 19-912
8 5-1/2
11 11-3/4
212-0140 to 212-1640
11 10
40 2-1/4
19-114 to 19-914
8 5-1/2
13 11-3/4
214-0148 to214-1248
13 11-1/4
47 8-1/2
110-112 to 110-912
9 9-3/4
11 11-3/4
214-552 to 214-952
13 11-1/4
51 8-1/4
39-336 to 39-936
8 5-1/2
36 4-1/4
39-242 to 39-942
8 5-1/2
42 4-1/4
3-CELL
1-CELL
Model No.
110-118 to 110-918
9 9-3/4
18 0
112-012 to 112-912
11 10
11 11-3/4
112-314 to 112-914
11 10
13 11-3/4
310-136 to 310-936
9 9-3/4
36 4-1/4
112-018 to 112-918
11 10
18 0
310-154 to 310-954
9 9-3/4
54 5
112-520 to 112-920
11 10
20 0
312-036 to 312-936
11 10
36 4-1/4
114-0124 to114-1324
13 11-1/4
23 9
312-042 to 312-942
11 10
42 4-1/4
114-526 to 114-926
13 11-1/4
25 8-7/8
312-054 to 312-954
11 10
54 5
26-517 to 26-917
5 11-7/8
17 1-1/2
312-260 to 312-960
11 10
60 5
28-217 to 28-917
7 5-7/8
17 1-1/2
314-0172 to 314-1272
13 11-1/4
71 8
29-318 to 29-918
8 5-1/2
18 0
314-578 to 314-978
13 11-1/4
77 7-5/8
Notes:
Models Listed Above.
1. These are suggested arrangements for preliminary layout purposes. Consult your EVAPCO representative for factory certified steel support drawings.
2. The recommended support for the AT/UT/USS Cooling Tower is structural I-beams located under the outer flanges and running the entire length of the unit. The unit
should be elevated to allow access underneath the unit and to the roof below. Mounting holes, 3/4 in diameter, are located in the bottom flanges of the pan to provide for
bolting to the structural steel.
3. Beams should be sized in accordance with accepted structural practices. Maximum deflection of beam under unit to be 1/360 of the unit length, not to exceed 1/2.
4. For these models where two support beams are required, deflection may be calculated by using 55% of the operating weight as a uniform load on each beam.
5. Beams should be level before setting the unit in place. Do not level the unit by shimming between it and the I-beams.
6. Support beams and Anchor bolts are to be furnished by others.
7. Dimensions, weights and data are subject to change without notice. Refer to the factory certified drawings for exact dimensions.
8. For alternate layout arrangements please consult the factory. NOTE: OPTIONALBOTTOMCONNECTIONSWILLREQUIRETHEUNITTOBEELEVATED TO ALLOW
FOR PIPING.
87
End Elevation
Plan View
4-CELL
2-CELL
Model No.
Dimensions
W
212-59 to 212-99
12 4-7/8
8 5-1/2
215-29 to 215-99
15 4-7/8
8 5-1/2
217-59 to 217-99
17 4-1/8
8 11-1/2
217-111 to 217-911
17 4-1/8
10 5-1/2
217-412 to 217-912
17 4-1/8
11 11-3/4
217-214 to 217-914
17 4-1/8
13 11-3/4
220-112 to 220-912
20 0-5/8
11 11-3/4
220-118 to 220-918
20 0-5/8
18 0
224-018 to 224-918
24 1-1/8
18 0
224-720 to 224-920
24 1-1/8
20 0
228-0124 to 228-1024
28 3-5/8
23 9
228-526 to 228-926
28 3-5/8
25 8-7/8
420-124 to 420-924
20 0-5/8
24 1-3/4
420-136 to 420-936
20 0-5/8
36 2-1/4
424-024 to424-924
24 1-1/8
24 1-3/4
424-028 to 424-928
24 1-1/8
28 1-3/4
424-036 to 424-936
24 1-1/8
36 2-1/4
424-0140 to 424-1640
24 1-1/8
40 2-1/4
428-0148 to 428-1348
28 3-5/8
51 1
428-552 to 428-952
28 3-5/8
55 0-3/4
Notes:
Models Listed Above.
1. These are suggested arrangements for preliminary layout purposes. Consult your EVAPCO representative for factory certified steel support drawings.
2. The recommended support for the AT/UT/USS Cooling Tower is structural I-beams located under the outer flanges and running the entire length of the unit. The unit should
be elevated to allow access underneath the unit and to the roof below. Mounting holes, 3/4 in diameter are located in the bottom flanges of the pan to provide for bolting
to the structural steel.
3. Beams should be sized in accordance with accepted structural practices. Maximum deflection of beam under unit to be 1/360 of the unit length, not to exceed 1/2.
4. For these models only where three support beams are required, deflection may be calculated using 56% of the operating weight on the CENTERBEAM and 22% on each
OUTBOARDbeam.
5. Beams should be level before setting the unit in place. Do not level the unit by shimming between it and the I-beams.
6. Support beams and Anchor bolts are to be furnished by others.
7. Dimensions, weights and data are subject to change without notice. Refer to the factory certified drawings for exact dimensions.
8. For alternate layout arrangements please consult the factory. NOTE: OPTIONAL BOTTOM CONNECTIONS WILL REQUIRE THE UNIT TO BE ELEVATED TO ALLOW
FOR PIPING.
88
End Elevation
Plan View
End Elevation
Plan View
Model No.
342-526 to 342-926
456-526 to 456-926
42 8
57 3/8
25 8-7/8
25 8-7/8
Notes:
Models Listed Above.
1. These are suggested arrangements for preliminary layout purposes. Consult your EVAPCO representative for factory certified steel support drawings.
2. The recommended support for the AT/UT/USS Cooling Tower is structural I-beams located under the outer flanges and running the entire length of the unit. The unit
should be elevated to allow access underneath the unit and to the roof below. Mounting holes, 3/4 in diameter are located in the bottom flanges of the pan to provide for
bolting to the structural steel.
3. Beams should be sized in accordance with accepted structural practices. Maximum deflection of beam under unit to be 1/360 of the unit length, not to exceed 1/2.
4. For these models only where four or five support beams are required, deflection may be calculated using 56% of the operating weight on the CENTERBEAMS and 22% on
each OUTBOARDbeam.
5. Beams should be level before setting the unit in place. Do not level the unit by shimming between it and the I-beams.
6. Support beams and Anchor bolts are to be furnished by others.
7. Dimensions, weights and data are subject to change without notice. Refer to the factory certified drawings for exact dimensions.
8. For alternate layout arrangements please consult the factory. NOTE: OPTIONAL BOTTOM CONNECTIONS WILL REQUIRE THE UNIT TO BE ELEVATED TO ALLOW FOR
PIPING.
89
Notes
90
World Headquarters/
Research and
Development Center
EVAPCO Facilities
1M/0613/YGS
Bulletin 331F
EVAPCOLD
521 Evapco Drive
Greenup, Ill USA
217-923-3431 p
evapcomw@evapcomw.com
EVAPCO-BLCT Dry Cooling, Inc.
981 US Highway 22 West
Bridgewater, New Jersey 08807 USA
1-908-379-2665 p
info@evapco-blct.com
Refrigeration Valves &
Systems Corporation
A wholly owned subsidiary of EVAPCO, Inc.
1520 Crosswind Dr.
Bryan, TX 77808 USA
979-778-0095 p | 979-778-0030 f
rvs@rvscorp.com
Europe
Asia/Pacific
EVAPCO Northwest
5775 S.W. Jean Road, Suite 104
Lake Oswego, Oregon 97035 USA
503-639-2137 p | 503-639-1800 f
EvapTech, Inc.
A wholly owned subsidiary of EVAPCO, Inc.
8331 Nieman Road
Lenexa, KS 66214 USA
913-322-5165 p | 913-322-5166 f
marketing@evaptech.com
South America
EVAPCO SEMCO
Equipamentos de Refrigeracao Ltda.
Rua Alexandre Dumas, 1601 - 2 andar
04717-004 Sao Paulo - SP - Brazil
(55) 11-5184-0067 p
Visit us at evapco.com.
Committed to making life easier, more reliable and more sustainable for people everywhere