Вы находитесь на странице: 1из 1

Products covered by this installation instruction

Stock No
S1605P
S1605S
S1605TC
S1606S
S1606TC
S1607S
S1608P
S1608S
S1614TC
S1615TC
S1636RS
S1636GS
S1678RS

Description
Button and LED
Button and LED
Button and LED
Button
Button
Button
Button
Button
Two LEDs
Button & two LEDs
Jumbo LED (Red)
Jumbo LED (Green)
Jumbo LED (Red) & Sounder

Material
Plastic
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Plastic
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel

Printing/Engraving
Press to Call
Press to Call
(Own Text 46 chars)
Press to Exit
(Own Text 18 chars)
Press to Enter
Press to Reset
Press to Reset
(Own Text 18 chars)
(Own Text 18 chars)

All the above items are dimensionally compatible with single gang BS4662 fittings. They
are designed for operation on 12 volts DC. NOT to be used on 240v mains. All are
supplied with a mounting box, surface plastic pattress box or a 34 mm deep galvanised
flush box in the case of the stainless steel units.

White

-ve
LED
+ve

Red

Red

NC

Yellow

Jumbo LEDs follow this convention

Black

-ve
LED
+ve
Bz -ve

Epoxy Cement

2mm

COM

All Pushbuttons or Keyswitches follow


the above colour convention

All LEDs follow the above

7mm

NO

Blue
Black

35mm

If stainless steel units are to be fitted in


areas where they may be subjected to
deliberate attack they should be
recessed below the surface of the wall.
A cavity should be constructed as
shown . The inner cavity should be 76 x
76 (mm) to a depth of at least 42mm.
The second cavity should be 91 x 91
(mm) and approx 7mm deep. The
galvanised socket box should be fitted
with two wood screws and suitable wall
plugs to ensure that the box is totally
secure. The cable entry should be either
rear or side entry. For iniital testing and
commissioning use conventional M3.5
countersunk fixing screws to secure the
call point. When it has been established
that the system is working correctly
replace these screws with security
screws. A gap filling epoxy cement
should be used to form a seal between
the stainless steel plate and the wall.

and where fitted a sounder follows


this convention

WARNING! The stainless steel version may have sharp edges. This is
not a problem post installation but please exercise care when handling
and during installation.
On the stainless steel versions of this product the jumbo LED is supplied loose to prevent
damage in transit. It should be clipped into place on installation.
Dwg No. 60068:0 Iss 3 Feb 2008

S0610 Mounting Spacer


Although Stainless steel units are generally
intended for flush fitting using the galvanised
box provided they can be surface mounted using
the S0610 mock stainless steel mounting
spacer.
The galvanised box should be mounted in the
required position and the cable entries made.
The S0610 spacer is then placed over the box,
the relevant terminations made off and the plate
screwed down on to the box. The spacer is
therefore gripped between the wall and the
plate.

S0610 Mounting Spacer


Galvanised Box
Stainless Steel Plate

Hoyles Electronic Developments Ltd


Sandwash Close, Rainford Ind Est, Rainford, St Helens, WA11 8LY.
T.01744 886600 F.01744 886607 E.sales@hoyles.com W.www.hoyles.com