Superheat, Reheat

Attemperator Spray
Service in Fossil Plants
FCD ADAMS8025-00

The Problem

To Final Superheat

Figure A

Steam temperature control is required at the outlet of superheaters and reheaters. It is normally accomplished through spray water
injection, controlled by a modulating control valve. During low-load
conditions, the control valve is ineffective, resulting in leakage
which may lead to turbine water induction as load is subsequently
increased. For this reason, a power-operated Block Valve is recommended for tight shutoff.1 See Figures A and B.

Spray Control
Valve
Block
Valve

Attemperator

Figure B

The Solution
In many cases, older plants do not have the recommended Block
Valve. In some cases, a second Control Valve or Globe Valve has
been installed to provide tight shutoff. Optimum tight shutoff for this
service can be attained with a Double-Disc Gate Valve. Anchor/Darling Double-Disc Gate Valves can be furnished with pneumatic or
electric motor actuation to provide excellent isolation in low-load
circumstances. Anchor/Darling Control Valves, such as the Spray
Control Valve can provide the longevity of service required by this
application. Anchor/Darling Valve Company can furnish a unit package of both Control and Block Valves, each designed to the specic
task assigned it. Consult your Anchor/Darling representative.
Refer to ASME Standard TDP-1-1980, Sections 3.2 and 3.5.

Cold Reheat Pipe

Spray
Control
Valve
Block
Valve

Attemperator

Manual
Test
Valve

Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to
perform its intended function safely during its useful life. However, the purchaser or
user of Flowserve products should be aware that Flowserve products might be used in
numerous applications under a wide variety of industrial service conditions. Although
Flowserve can (and often does) provide general guidelines, it cannot provide specic
data and warnings for all possible applications. The purchaser/user must therefore
assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and
understand the Installation Operation Maintenance (IOM) instructions included with the
product, and train its employees and contractors in the safe use of Flowserve products
in connection with the specic application.
While the information and specications contained in this literature are believed to be
accurate, they are supplied for informative purposes only and should not be considered
certied or as a guarantee of satisfactory results by reliance thereon. Nothing contained
herein is to be construed as a warranty or guarantee, express or implied, regarding any
matter with respect to this product. Because Flowserve is continually improving and
upgrading its product design, the specications, dimensions and information contained
herein are subject to change without notice. Should any question arise concerning
these provisions, the purchaser/user should contact Flowserve Corporation at any one
of its worldwide operations or ofces.
For more information about Flowserve Corporation, visit www.owserve.com or call
USA 1-800-225-6989.

2004 Flowserve Corporation, Irving, Texas, USA. Flowserve is a registered trademark of Flowserve Corporation.

(Part SAS)
FCD ADAMS8025-00 Printed in USA.

Вам также может понравиться