Академический Документы
Профессиональный Документы
Культура Документы
E
TOSHIBA COMPACT MACHINE ROOM ELEVATORS
TOSHIB
TB408_[001-012]_MY.indd 1
09.9.17 10:23:33 AM
Hoistway layout
Counterweight at side
Window
(By general contractor)
Ventilation fan
(By general contractor)
Control panel
Power Switch
(By general contractor)
Overhead OH
Door height
Dust-proofed
(By general contractor)
Lighting switch
inspection receptacle
(By general contractor)
Top floor
Hoistway
centerline
Hoistway depth Y
Total height
Travel
Car centerline
Ladder
Bottom floor
Pit depth P
(By general
contractor)
Hoistway lighting
(By general contractor)
Pit waterproof
(By general contractor)
Hoistway section
Hoistway plan
TB408_[001-012]_MY.indd 2
09.9.17 10:23:38 AM
Specifications
Nos.of Capacity Speed
Person (kg) (m/s)
Type
P8-CO60
P8-CO96
P8-CO105
P8-CO120
P8-CO150
P11-CO60
P11-CO96
P11-CO105
P11-CO120
P11-CO150
P11-CO60
P11-CO96
P11-CO105
P11-CO120
P11-CO150
P13-CO60
P13-CO96
P13-CO105
P13-CO120
P13-CO150
P14-CO60
P14-CO96
P14-CO105
P14-CO120
P14-CO150
W
W
1.6
W
W
545
W
W
2.5
W
W
W
W
1.6
W
W
11
750
W
W
2.5
W
D
D
D
1.6
D
D
11
750
D
D
2.5
D
W
W
W
1.6
W
W
13
885
W
W
2.5
W
D
D
D
1.6
D
D
D
D
D
D
1.75 16001400
2
1.75 11001700
2
1.75 13501400
2
1.75 11001400
2
Door width
W
(mm)
Internal (A x B)
Cage size
(mm)
14
955
1.75 11002100
2
2.5
Machine room
dimensoins (mm)
XxY
800
18201770
900
20001770
800
18201770
900
20001770
800
18201770
900
20001770
800
18201770
900
20001770
800
18201770
900
20001770
800
19451770
900
20501770
800
19451770
900
20501770
800
19451770
900
20501770
800
19451770
900
20501770
800
19451770
900
20501770
800
18202070
900
20002070
800
18202070
900
20002070
800
18202070
900
20002070
800
18202070
900
20002070
800
18202070
900
20002070
900
21751770
1000
22751770
900
21751770
1000
22751770
900
21751770
1000
22751770
900
21751770
1000
22751770
900
21751770
1000
22751770
800
18202470
900
20002470
800
18202470
900
20002470
800
18202470
900
20002470
800
18202470
900
20002470
800
18202470
900
20002470
OH
4050 1300
4300 1400
4300 1450
4350 1650
4350 2100
4050 1300
4300 1400
4300 1450
4350 1650
4350 2100
4050 1300
4300 1400
4300 1450
4350 1650
4350 2100
4050 1300
4300 1400
4300 1450
4350 1650
4350 2100
4050 1300
4300 1400
4300 1450
4350 1650
4350 2100
M.A x M.B
M.H
18201770
3.6
24
60
5.8
32
100
6.3
32
100
7.2
40
125
9.0
40
125
4.6
24
60
7.3
32
100
8.0
32
100
9.2
40
125
11.4
40
125
4.6
24
60
7.3
32
100
8.0
32
100
9.2
40
125
11.4
40
125
5.7
24
60
9.2
32
100
2000 10.0
32
100
11.4
40
125
14.3
40
125
5.7
24
60
9.2
32
100
2000 10.0
32
100
11.4
40
125
14.3
40
125
20001770
18201770
20001770
18201770
20001770
2000
18201770
20001770
18201770
20001770
19451770
20501770
19451770
20501770
19451770
20501770
2000
19451770
20501770
19451770
20501770
18202070
20002070
18202070
20002070
18202070
20002070
18202070
20002070
18202070
20002070
21751770
22751770
21751770
22751770
21751770
22751770
21751770
22751770
21751770
22751770
18202470
20002470
18202470
20002470
18202470
20002470
18202470
20002470
18202470
20002470
Motor
Max.
Max.
capacity service travel
(kw) stops (s) (m)
2000
Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
Example: P13W W: Wide car D: Deep car
TB408_[001-012]_MY.indd 3
09.9.17 10:23:42 AM
Hoistway layout
Counterweight at side
Power switch
(By general contractor)
Ventilation fan
(By general contractor)
Control panel
Overhead OH
Door height
Dust-proofed
(By general contractor)
Window
(By general contractor)
Lighting switch
inspection receptacle
(By general contractor)
Car
centerline
Hoistway depth Y
Hoistway
centerline
Top floor
Total height
Travel
Pit depth P
Hoistway lighting
(By general contractor)
Hoistway depth Y
Car
centerline
Bottom floor
Hoistway
centerline
Pit waterproof
(By general contractor)
Hoistway section
TB408_[001-012]_MY.indd 4
09.9.17 10:23:46 AM
Specifications
Nos.of Capacity Speed
Person (kg) (m/s)
Type
P17-CO60
P17-CO96
P17-CO105
P17-CO120
P17-CO150
W
W
1.6
W
W
Door width
W
(mm)
Internal (A x B)
Cage size
(mm)
17
W
W
2.5
Machine room
dimensoins (mm)
XxY
1000
25001980
1100
26001980
1000
25001980
1100
26001980
1000
25001980
1100
26001980
1000
25001980
1100
26001980
1000
25001980
1100
26001980
OH
4050 1300
4300 1400
4300 1450
4350 1650
4700 2100
M.A x M.B
25001980
26001980
25001980
26001980
25001980
26001980
25001980
26001980
25001980
26001980
M.H
Motor
Max.
Max.
capacity service travel
(kw) stops (s) (m)
7.3
24
60
11.6
32
100
2000 12.6
32
100
14.4
40
125
18.0
40
125
P19-2S60
4050 1300
8.7
24
60
P19-2S96
1.6
4300 1400
14.0
32
100
P19-2S105
2200 16.0
32
100
P19-2S120
4350 1650
18.0
40
125
P19-2S150
2.5
4700 2100
20.0
40
125
P24-2S60
4050 1300
10.0
24
60
P24-2S96
1.6
4300 1400
16.0
32
100
P24-2S105
2200 18.0
32
100
P24-2S120
4350 1650
20.0
40
125
P24-2S150
2.5
4700 2100
24.0
40
125
19
24
1100
1200
21003050
23003150
4300 1450
4300 1450
21003050
23003150
Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
Example: P17W W: Wide car D: Deep car
TB408_[001-012]_MY.indd 5
09.9.17 10:23:49 AM
Hoistway layout
Counterweight at rear
Lighting switch
inspection receptacle
(By general contractor)
Door height
Window
(By general contractor)
Ventilation fan
(By general contractor)
Power switch
(By general contractor)
Control panel
Overhead OH
Dust-proofed
(By general contractor)
Top floor
Hoistway depth Y
Total height
Travel
Hoistway width X
Ladder
(By general contractor)
Hoistway plan
Pit depth P
Bottom floor
Hoistway lighting
(By general contractor)
Pit waterproof
(By general contractor)
Hoistway section
TB408_[001-012]_MY.indd 6
09.9.17 10:23:53 AM
Specifications
Type
P8-CO60
P8-CO96
P8-CO105
P8-CO120
P8-CO150
P11-CO60
P11-CO96
P11-CO105
P11-CO120
P11-CO150
P13-CO60
P13-CO96
P13-CO105
P13-CO120
P13-CO150
W
W
1.6
W
W
545
W
W
2.5
W
W
W
W
1.6
W
W
11
750
W
W
2.5
W
W
W
W
1.6
W
W
W
W
W
W
1.75 14001350
2
1.75 14001100
2
Door width
W
(mm)
Internal (A x B)
Cage size
(mm)
13
885
1.75 16001400
2
2.5
Machine room
dimensoins (mm)
XxY
800
18501680
900
19501680
800
18501680
900
19501680
800
18501680
900
19501680
800
19501780
900
20501780
800
19501780
900
20501780
800
18502000
900
19502000
800
18502000
900
19502000
800
18502000
900
19502000
800
19502100
900
20502100
800
19502100
900
20502100
900
21002050
1000
22002050
900
21002050
1000
22002050
900
21002050
1000
22002050
900
22002150
1000
23002150
900
22002150
1000
23002150
OH
4050 1300
4300 1400
4300 1450
4350 1650
4350 2100
4050 1300
4300 1400
4300 1450
4350 1650
4350 2100
4050 1300
4300 1400
4300 1450
4350 1650
4350 2100
M.A x M.B
M.H
18501680
3.6
24
60
5.8
32
100
6.3
32
100
7.2
40
125
9.0
40
125
4.6
24
60
7.3
32
100
8.0
32
100
9.2
40
125
11.4
40
125
5.7
24
60
9.2
32
100
2000 10.0
32
100
11.4
40
125
14.3
40
125
19501680
18501680
19501680
18501680
19501680
2000
19501780
20501780
19501780
20501780
18502000
19502000
18502000
19502000
18502000
19502000
19502100
20502100
19502100
20502100
21002050
22002050
21002050
22002050
21002050
22002050
22002150
23002150
22002150
23002150
Motor
Max.
Max.
capacity service travel
(kw) stops (s) (m)
2000
Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
Example: P13W W: Wide car
TB408_[001-012]_MY.indd 7
09.9.17 10:23:57 AM
Hoistway layout
Counterweight at rear
Window
(By general contractor)
Ventilation fan
(By general contractor)
Door height
Lighting switch
inspection receptacle
(By general contractor)
Control panel
Power switch
(By general contractor)
Overhead OH
Dust-proofed
(By general contractor)
Power switch
(By general contractor)
Control panel
Ventilation fan
(By general contractor)
Total height
Travel
Lighting switch
inspection receptacle
(By general contractor)
Pit depth P
Bottom floor
Hoistway lighting
(By general contractor)
Hoistway depth Y
Ladder
(By general contractor)
Pit waterproof
(By general contractor)
Hoistway section
Door opening width W
Car inside width A
Hoistway width X
Hoistway plan
7
TB408_[001-012]_MY.indd 8
09.9.17 10:24:01 AM
Specifications
Nos.of Capacity Speed
Person (kg) (m/s)
Type
P17-CO60
P17-CO96
P17-CO105
P17-CO120
P17-CO150
W
W
1.6
W
W
Door width
W
(mm)
Internal (A x B)
Cage size
(mm)
17
W
W
2.5
Machine room
dimensoins (mm)
XxY
1000
23002190
1100
24502190
1000
23002190
1100
24502190
1000
23002190
1100
24502190
1000
23002190
1100
24502190
1000
23002190
1100
24502190
OH
4050 1300
4300 1400
4300 1450
4350 1650
4700 2100
M.A x M.B
M.H
23002190
7.3
24
60
11.6
32
100
2200 12.6
32
100
14.4
40
125
18.0
40
125
24502190
23002190
24502190
23002190
24502190
Motor
Max.
Max.
capacity service travel
(kw) stops (s) (m)
23002190
24502190
23002190
24502190
P19-CO60
4050 1300
8.7
24
60
P19-CO96
1.6
4300 1400
14.0
32
100
P19-CO105
2200 16.0
32
100
P19-CO120
4350 1650
18.0
40
125
P19-CO150
2.5
4700 2100
20.0
40
125
P20-CO60
4050 1300
8.7
24
60
P20-CO96
1.6
4300 1400
14.0
32
100
P20-CO105
2200 16.0
32
100
P20-CO120
4350 1650
18.0
40
125
P20-CO150
2.5
4700 2100
20.0
40
125
10.0
24
60
16.0
32
100
2200 18.0
32
100
20.0
40
125
24.0
40
125
12.0
24
60
18.0
32
100
P24-CO60
P24-CO96
P24-CO105
P24-CO120
P24-CO150
19
20
W
W
1.6
W
W
W
24
W
W
2.5
P27-CO60
P27-CO96
1100
1100
25502200
25502250
1100
25502500
1200
27002500
1100
25502500
1200
27002500
1100
25502500
1200
27002500
1100
25502500
1200
27002500
1100
25502500
1200
27002500
1800
4300 1450
4050 1300
4300 1400
4300 1450
4350 1650
4700 2100
25502200
25502250
25502500
27002500
25502500
27002500
25502500
27002500
25502500
27002500
25502500
27002500
4050 1400
1.6
27
4300 1450
4300 1550
21001900
1200
27002600
27002600
2200
P27-CO105
1.75
4300 1650
20.0
32
100
P27-CO120
4350 1900
22.0
40
125
Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
Example: P17W W: Wide car
TB408_[001-012]_MY.indd 9
09.9.17 10:24:05 AM
Hoistway layout
Power switch
(By general contractor)
Ventilation fan
(By general contractor)
Control panel
Overhead OH
Dust-proofed
(By general contractor)
Window
(By general contractor)
Door height
Lighting switch
inspection receptacle
(By general contractor)
Total height
Travel
Hoistway depth Y
Top floor
Car
centerline
Pit depth P
Bottom floor
Hoistway lighting
(By general contractor)
Hoistway depth Y
Ladder
(By general contractor)
Hoistway
centerline
Pit waterproof
(By general contractor)
TB408_[001-012]_MY.indd 10
09.9.17 10:24:08 AM
Specifications
Nos.of Capacity Speed
Person (kg) (m/s)
Type
Cage size
(mm)
Door width
W
(mm)
Internal (A x B)
Machine room
dimensoins (mm)
XxY
OH
M.A x M.B
M.H
Motor
Max.
Max.
capacity service travel
(kw) stops (s) (m)
P14-CO60
D2
4050 1300
5.7
P14-CO96
D2
1.6
4300 1400
9.2
P14-CO105
D2
P14-CO120
D2
4350 1650
11.4
P14-CO150
D2
2.5
4350 2100
14.3
P24-2S60
D2
4050 1300
10.0
P24-2S96
D2
1.6
4300 1400
16.0
P24-2S105
D2
P24-2S120
D2
4350 1650
20.0
P24-2S150
D2
2.5
4700 2100
24.0
14
24
955
1.75 11002100
800
1200
18202610
23003270
4300 1450
4300 1450
18202610
23003270
2000 10.0
2200 18.0
Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
The front and rear opening floor are less than 8 floor
Example: P13D2 D2Front and rear opening door deep car
10
TB408_[001-012]_MY.indd 11
09.9.17 10:24:11 AM
Safety Cautions
TB408_[001-012]_MY.indd 12
09.9.17 10:24:20 AM