Академический Документы
Профессиональный Документы
Культура Документы
Assumption
The column splice is just above floor level (about 500mm above)
hence moment due to strut is considered insignificant
Code requirements
Splice should hold the connected members in place.
Centroidal axis of the splice should coincide with the centroidal
axis of the members.
Splice should provide continuity of stiffness about both axes and
resist any tension where bending is present.
2
=
140 103
307.8
400
2
= 255kN
Pt = pyAfp
Aft = effective area of flange cover plate
= KeApnet Apgross
Ke = 1.2 for Gr 43
Apgross = 305 x 10 = 3050 mm2
Apnet = Apgross - 2Dhtcp
= 3050 2 x26x 10
= 2530 mm2
ke Apnet = 1.2 x 2530 = 3036 mm2
Since ke Apnet < Apgross
Pt = 275 x 3026 = 835 kN
Ft (255 kN) < Pt (835 kN)
Tensile capacity of flange cover plate is ok