UPDATING OF RATES FOR CONSTRUCTION OF UNIT QUANTITY ITEMS OF 220 KV /132 KV LINE ON
LABOUR CONTRACT BASIS [ NEW BSR ]

Formula :- E1 = E:0 (0.25 +0.2xD1/D0+0.55xL1/L0 )


Base Diesel (D0) 1.01.04 22.92
Base Labour (LO) 1.01.04 504
Diesel (D1) 1.04.06 33.07
Labour (L1)1.04.06 556
PV Factor (0.25+0.2x33.07/22.92+0.55x556/504) 1.15

S.No Descripation Unit Rate(Rs) Qty Amount


1 Detail Survey as per tentative route
1
Which includes the following major activities Pegging of line route
providing of survey pillar at an interval of 3-4 KM in the line route
with required jungle dearance for survey profile preparation of
approved route on graph sheet and marking of offset on either side of
line marking of side clearance for hills, sand dunes etc, as per
spedificaltion and tower scheduling. KM 3482.00

2 Check survey as per approved route of line which includes-


Re-checking of the line route as per approved profile chainage tower
center marking pit marking bisection of angle tower as required at
site. KM 1294.00

3 Excavation
Excavation, excluding back filling, including shoring shuttering,
dewatering etc upto the required depth as per foundation
specification / drawings.
i) Normal soil CUM 103.00
ii) Murram / Black cotton/ Hard Soil/Dense soil CUM 218.00
iii) Solt rock/disintegrated rock CUM 241.00
iv) Hard rock (blasting prohibtted ) CUM 550.00
v) Hard rock (with blasting ) CUM 504.00
vi) Submerged Hard/Normal marine soil CUM 149.00

4 SETTING OF TEMPLATE & STUB /ANCHOR BOLT

Selling of template & stub / enchor bolt & removal after concreting,
excluding cost of excavation and concreting but including back filling
with excavated / borrowed earth (with lead & lift ) in layers with
ramming andwatering as specification.
(A) 132 KV Single Circuit Tower upto +6m extension.
(i) Tangent Tower (TTA) Nos 1019
ii) Small angle Tower (TTB) Nos 1168
iii) Medium angle Tower (TTC) Nos 1706
iv) Large angle cum dead end Tower (TTD) Nos 1764

(B) 132 KV Double Circuit Tower upto+6m extension


(i) Tangent Tower (TTA) Nos 1329.00
ii) Small angle Tower (TTB) Nos 1855.00
iii) Medium angle Tower (TTC) Nos 2004.00
iv) Large angle cum dead end Tower (TTD) Nos 2153.00

( C) 220 KV Single Circuit Tower upto+6mextension


(i) Tangent Tower (TTA) Nos 1477.00
ii) Small angle Tower (TTB) Nos 1775.00
iii) Medium angle Tower (TTC) Nos 2073.00
iv) Large angle cum dead end Tower (TTD) Nos 2371.00
Page 2 of 7
(D) 220 KV Double Circuit Tower upto+6m extension
(i) Tangent Tower (TTA) Nos 1775.00
ii) Small angle Tower (TTB) Nos 2073.00
iii) Medium angle Tower (TTC) Nos 2520.00
iv) Large angle cum dead end Tower (TTD) Nos 2966.00

(E) 220 KV Double Circuit Special Tower (TTA)upto +18m extension


for span up to 550m Nos 2966.00

(F) 220KV Double Circuit Special Tower (TTA)upto +18m extension


for span exceeding 550m Nos 2966.00

5 CONCRETING

Providing and laying cement concrete for all types of foundation as


per latest ISS:456 including cement sand, stone aggregate 20mm
nominal size water etc preparling surfaces, shuttering, mixing,
placing ramming, curing, finishing as per specification and drawings.
i) 1:4:8 Mix CUM 3012.00
ii) 1:3:6 Mix CUM 3390.00
iii) 1:2:4 Mix CUM 3493.00
iv) 1:1:5:3 Mix CUM 4261.00

6 Cutting bending, welding of joints if required, flxing and plasing of


steel relnforcement as per specification and drawings including
material. MT 30568.00

7 EARTHING :

(a) Earthing of towers with pipe type earthing excluding the supply of
pipes, wire.flats & connectors, but including coke / charcoal etc,
excavation, angering and backfilling in all types of soil. Set 779.00

(B) Earthing to towers legs with counterpoise typearthings excluding


supply of materials but including excavation and backfilling in all
types of soil.
(i) each set by laying 4 wires each 15mm long at a depth of 600mm Set 974.00
(ii) each set by laying 4 wires each 25mm long at a depth of 600mm Set 1626.00

8 ERECTION OF TOWERS :

Erection of super strcutures including D-shackles, ACD, Hangers U-


Bolts, step bolts, danger, plate, phase plate, number plate etc. Also
including tack welding of bolts & nuts upto bottom cross arm / beam
level including application of zine Rich paint.
(A) 132 KV Single Circuit Tower
(i) Tangent Tower (TTA) Nos 3779.00
ii) Small angle Tower (TTB) Nos 4444.00
iii) Medium angle Tower (TTC) Nos 4742.00
iv) Large angle cum dead end Tower (TTD) Nos 6666.00

(B) 132 KV Double Circuit Tower


(i) Tangent Tower (TTA) Nos 5245.00
ii) Small angle Tower (TTB) Nos 7559.00
iii) Medium angle Tower (TTC) Nos 8910.00
iv) Large angle cum dead end Tower (TTD) Nos 12209.00

( C) 220 KV Single Circuit Tower


(i) Tangent Tower (TTA) Nos 5692.00
ii) Small angle Tower (TTB) Nos 7250.00
iii) Medium angle Tower (TTC) Nos 8281.00
iv) Large angle cum dead end Tower (TTD) Nos 10880.00
Page 3 of 7
(D) 220 KV Double Circuit Tower
(i) Tangent Tower (TTA) Nos 8281.00
ii) Small angle Tower (TTB) Nos 12438.00
iii) Medium angle Tower (TTC) Nos 13469.00
iv) Large angle cum dead end Tower (TTD) Nos 18050.00

E 220 KV Double Circuit Special Tower for span up to 550m


i) Normal Structure Nos 18119.00
ii) 44.5M Ext to Normal structure Nos 4455.00
iii) 49.0M Ext to Normal structure Nos 9082.00
iv) 418.0M Ext to Normal structure Nos 18531.00

F 220 KV Double Circuit Special Tower for span exceeding 550m 24395.00
i) Normal Structure Nos 4409.00
ii) 44.5M Ext to Normal structure Nos 8853.00
iii) 49.0M Ext to Normal structure Nos 18680.00
iv) 418.0M Ext to Normal structure Nos

9 Erection of 3 meters extension including tack welding of all bolts &


nuts and application of zinc rich paint.
(A) 132 KV Single Circuit Tower
i) Tangent Tower (TTA) Nos 630.00
ii) Small angle (TTB) Nos 882.00
iii) Medium angle Tower (TCC) Nos 1042.00
iv) Large angle cum dead end Tower (TTD) Nos 1271.00

(B) 132 KV Double Circuit Tower


i) Tangent Tower (TTA) Nos 302.00
ii) Small angle (TTB) Nos 1122.00
iii) Medium angle Tower (TCC) Nos 1329.00
iv) Large angle cum dead end Tower (TTD) Nos 1615.00

(C) 220 KV Single Circuit Tower


i) Tangent Tower (TTA) Nos 559.00
ii) Small angle (TTB) Nos 1203.00
iii) Medium angle Tower (TCC) Nos 1420.00
iv) Large angle cum dead end Tower (TTD) Nos 1729.00

(D) 220 KV Double Circuit Tower


i) Tangent Tower (TTA) Nos 1145.00
ii) Small angle (TTB) Nos 2034.00
iii) Medium angle Tower (TCC) Nos 2634.00
iv) Large angle cum dead end Tower (TTD) Nos 3482.00

10 Erection of 6 meters extension including tack welding of all bolts &


nuts and application of zinc rich paint.
(A) 132 KV Single Circuit Tower
i) Tangent Tower (TTA) Nos 1260.00
ii) Small angle (TTB) Nos 1661.00
iii) Medium angle Tower (TCC) Nos 2153.00
iv) Large angle cum dead end Tower (TTD) Nos 2508.00

(B) 132 KV Double Circuit Tower


i) Tangent Tower (TTA) Nos 1546.00
ii) Small angle (TTB) Nos 2039.00
iii) Medium angle Tower (TCC) Nos 2646.00
iv) Large angle cum dead end Tower (TTD) Nos 3081.00
Page 4 of 7
(C) 220 KV Single Circuit Tower
i) Tangent Tower (TTA) Nos 1718.00
ii) Small angle (TTB) Nos 2268.00
iii) Medium angle Tower (TCC) Nos 2932.00
iv) Large angle cum dead end Tower (TTD) Nos 3424.00

(D) 220 KV Double Circuit Tower


i) Tangent Tower (TTA) Nos 2176.00
ii) Small angle (TTB) Nos 2875.00
iii) Medium angle Tower (TCC) Nos 3722.00
iv) Large angle cum dead end Tower (TTD) Nos 4329.00

11 Erection of substation structures including leveling, setting of stub &


Tighting, Funching of Nuts & Bolts and tack welding upto beam level
as per specification. MT 2107.00

12 CONDUCTOR STRINGING

(A) Stringing of ACSR Panther including hoisting of insulator string,


laying, jointing & tensiong of conductor, clamping with Armour rods
and fixing of vibration damper per route KM of the line.
i) 3 conductor for S/C line KM 15771.00
ii) 6 conductor for D/C line KM 22963.00

(B) Stringing of ACSR Zebra including hoisting of insulator string,


laying, jointing & tensiong of conductor, clamping with Armour rods
and fixing of vibration damper per route KM of the line.
i) 3 conductor for S/C line KM 20718.00
ii) 6 conductor for D/C line KM 29423.00

(C) Stringing of ACSR Panther including hoisting of insulator string,


laying, jointing & tensiong of conductor, clamping with Armour rods
and fixing of vibration damper per route KM of the line crossing
section I.e from Anchor tower to Anchor tower for for regular flowing
river only.
i) 3 conductor for S/C line KM 20008.00
ii) 6 conductor for D/C line KM 29927.00

(D) Stringing of ACSR Zebra including hoisting of insulator string,


laying, jointing & tensiong of conductor, clamping with Armour rods
and fixing of vibration damper per route KM of the line crossing
section I.e from Anchor tower to Anchor tower for for regular flowing
river only.
i) 3 conductor for S/C line KM 26674.00
ii) 6 conductor for D/C line KM 38528.00

13 EARTHWIRE STRINGING
(A) Stringing of galvanised steel stranded wire including laying
jointing & tensioning, clamping , clipping and fixing vibration clamper
and earth bond etc.
i) One No. 7/3.15mm galvanised wire KM 3470.00
ii) One No. 7/4.00mm galvanised wire KM 4054.00
iii) Two No. 7/3.66mm galvanised wire KM 6070.00

(B) Stringing of galvanised steel stranded wire including laying


jointting & tensioning, clamping, clipping and fixing vibration clamper
and earth bond etc per route KM of the line for River crossing section
I.e from Anchor tower to Anchor tower for regular flowing river only.
i) One No. 7/3.15mm galvanised wire KM 3470.00
ii) One No. 7/4.00mm galvanised wire KM 4054.00
iii) Two No. 7/3.66mm galvanised wire KM 6070.00
Page 5 of 7
14 DISMANTLING OF TOWERS :
Dismantling of super structures alongwith extensions, having tack
welded Bolts & Nuts, including removing of D shackles hangers U
Bolts step bolts, ACD, Danger plate, number plate Phase plate of
tower including transportation from site to our store and stacking of
all material.
(A) 132 KV and 220 KV S/C & D/C Tower (all types) MT 2325.00
(B) 400 KV S/C & D/C Towers (all types) MT 2680.00
( C) 220 KV D/C special Tower MT 3264.00
(D) 400 KV S/C & D/C Special Tower MT 3979.00
(E) Sub station structures MT 2325.00

15 DESTRINGING OF CONDUCTOR / EARTH WIRE


(A) Destringing of ACSR Panther conductor :
Dismantling of vibration dampers and armour rods romoval of
conductor from clamps and fitting in rollers, detensloning, dehoisting
of insulator string as required and collecting the material & deposting
the same in our store and stacking.
i) 3 conductor for S/C line KM 17351.00
ii) 6 conductor for D/C line KM 25265.00

(B) Destringing of ACSR Zebra conductor

Dismantling of vibration clampers and armour rods removal of


conductor from clamps and fithing in rollers, detensioning, dehoisting
of insulator string as required and collecting the material & depositing
the same in our store and stacking.
i) 3 conductor for S/C line KM 22791.00
ii) 6 conductor for D/C line KM 22366.00

(C ) Destringing of Earth wire


Dismantling of earth bonds, vibration dampers, declipping & fitting in
rollers, detenstoning and collecting the material & depositing the
same in our store and stacking.
i) One No. 7/3.16mm galvanised wire. KM 2932.00
ii) One No. 7/4.00mm galvanised wire. KM 3424.00
iii) Two No. 7/3.66mm galvanised wire. KM 5142.00

16 RESTRINGING OF CONDUCTOR / EARTH WIRE.


(A) Restringing of ACSR Panther Conductor.

Dismantling of vibration dampers and armour rods, fitting in rollers,


de-tensioning holding & lowering of conductor, de-hoisting of
insulator string as required, adding / removing and jointing of
conductor, hoisting of insulator astring, lifting of conductinto rollers
and re-tensioning, jointing, fitting of armour rods and vibration
dampers and clamping per route KM of the line section to be restrung
dismantled material not re-used to be deposited in our stores &
stacked.
i) 3 conductor for S/C line KM 15771.00
ii) 6 conductor for D/C line KM 22963.00

(B) Restringing of ACSR Zebra Conductor.

Dismantling of vibration dampers and armour rods, fitting in rollers,


de-ensioning, holding & lowering of conductor, de-hosting of insulator
string as required. Adding / removing and jointing of conductor,
hoisting of insulator string, lifting of conductinto rollers and re-
tenstoning, jointing, fitting of armour rods and vibration dampers and
clamping per rote KM of the line section to be restruing dismantled
material not re-used to be deposited in our stores & stacked.
i) 3 conductor for S/C line KM 20718.00
ii) 6 conductor for D/C line KM 29423.00
Page 6 of 7
( C) Restringing of Earthwire :

Dismanting of earth bond, vivration dampers, declipping & fitting in


rollers, de-tensioning, holding & towering of Earthwire addong
removing and jointing of Earthwire, lifting ints rollers and re-
tensioning jointing clipping & fitting of Vibration dampers & earthbond
per route KM of line line section to be restrung Dismantled material;
not re-used to be deposited in our stores & stacked.
i) One No 7/3.15mm galvanised wire KM 2669.00
ii) One No 7/3.15mm galvanised wire KM 3115.00
iii) One No 7/3.15mm galvanised wire KM 4673.00

17 RIVETMENT OF TOWERS
(A) Providing and laying cement concrete including curing
complection etc complete using stone aggregate 40 mm nominal size
(crusher broken) in foundation plinth using 1 cement 5 Sand 10
aggregate mix. CUM 1260.00

(B) Random rubble stone masonary for rivetment in 1:5 cement


sound mortar including providing and fixing 100mm dia PCC drain
pipe & mised and cut pointing on stone masonary in 1:3 cement sand
mortar excluding excavation but including Back filling inside rivetment
using excavated / borrowed earth (with all leasd & lift ) in layers not
exceeding 20 cm in depath & consolidating each depos=ited layer by
ramming and watering. CUM 974.00

(C ) Random rubble dry stone pitching including preparing surface etc


complete with stone welghing 30 to 40 kg each and raised & cut
pcinting in cement sand mortar 1:3 curing etc. Mtr 286.00

(D) Cement conclete coping grade 1:2:4 (1 cement 2 Corese sand :4


graded stone aggregate ) rounding off edges etc, but excluding the
cost of nosing of steps etc complete for 50mm thick with 20mm thick
nominal size aggregate. Mtr 46.00

(E) Brick masonary in foundation & pllnth with bricks of class


designation 75 in cement mortar 1:5 [1 cement :5 coarse sand] CUM 1363.00

(F) Black on edge flooring with bricks of class designation 75


including pointing in cement mortar (1:3) complete lald on 12mm
thick bed of cement sand mortar 1:6 Mtr 137.00
Page 7 of 7
UPDATING OF RATES FOR CONSTRUCTION OF UNIT QUANTITY ITEMS OF 220 KV /132 KV LINE ON
LABOUR CONTRACT BASIS [ NEW BSR ]

Formula :- E1 = E:0 (0.25 +0.2xD1/D0+0.55xL1/L0 )


Base Diesel (D0) 1.01.04 22.92
Base Labour (LO) 1.01.04 504
Diesel (D1) 1.04.06 33.07
Labour (L1)1.04.06 556
PV Factor (0.25+0.2x33.07/22.92+0.55x556/504) 1.15

S.No Descripation Unit Rate(Rs) Qty Amount


1 Detail Survey as per tentative route
1

Which includes the following major activities Pegging of line route


providing of survey pillar at an interval of 3-4 KM in the line route
with required jungle dearance for survey profile preparation of
approved route on graph sheet and marking of offset o KM 3482.00