Production/Optimization Team
15-Mar-16
Table of Contents
Summary ....................................................................................................................................................... 2
1-Gas analysis at Kiln Inlet for Process Optimization.................................................................................... 3
2- Selection of sample point for Gas Analyzer Probe ................................................................................... 3
3- Location of Gas Analyzer Probe at Kiln Inlet ............................................................................................. 3
3.1- Standard location of Gas sampling probe at Kiln Inlet ...................................................................... 3
3.2- Sampling Point Probe installation (By ITECA) .................................................................................... 4
4- Location of Gas sampling probe at Kiln Inlet of BCL Chakwal .................................................................. 5
5- New Proposed Installed position of Inlet Gas Analyzer ............................................................................ 5
6- Comparison with Technical Sister Plants .................................................................................................. 6
6.1 Inlet Gas Analyzer Probe location at Kohat Cement (Technically sister Plant) ................................... 6
6.2- Gharibwal Cement (Position of Kiln inlet Analyzer Probe) ................................................................ 7
7- Recommendation: .................................................................................................................................... 7
References .................................................................................................................................................... 7
Page 1 of 7
Summary
Kiln inlet is the best spot for gas analysis for better process monitoring. An accurate
monitoring of process gasses at kiln inlet is of prime importance for optimized operation.
For better analysis of gas the probe of gas analyzer should be installed at correct location,
close to kiln seal on the side where the kiln wall is turning downwards (0-400mm in front
of the seal and up to 200 mm beyond the seal).
Chakwal Inlet analyzer position is not as per standard. The probe is located inside kiln
inlet chamber wall towards the side of kiln moving downwards.
Probe blockage is also a chronic issue being faced. This issue is because of installation of
probe inside kiln inlet Chamber. Dust content inside kiln inlet chamber is on higher side.
This was highlighted by Mr. Anis Haider (ITECA expert) and Mr. Sajjad Ullah (Team
Leader Optimization Pakcem).
World wide references are available for installation of Gas analyzer probe inside beyond
Kiln Inlet seal. (FLS +ITECA)
At BCL Chakwal since feed enters from both side (A & B) feed pipes into Kiln inlet. Due
to this design the probe location as per standard becomes critical.
Relocation of Probe sampling point at Kiln inlet is possible. This provides an opportunity
for plant optimization listed as under
1. Accurate analysis at kiln inlet.
2. Reducing the false air effect from Kiln inlet Seal.
3. Optimizing fuel consumption.
4. Optimizing power consumption
5. Reduce probe blockage.
6. More availability of Inlet gas Analyzer.
Page 2 of 7
Representative air
No influence of false air
Mechanical impact of material fall through
Risk of material build up
Dust impact
Condensation from volatiles
(FLSmidth, 2014) (Drawing Office Manual, 2008)
Page 3 of 7
Page 4 of 7
This was highlighted by Mr. Anis Haider (ITECA expert) and Mr. Sajjad Ullah (Team Leader
Optimization Pakcem).
Page 5 of 7
Kohat Cement is technically sister plant with same design of Kiln inlet and feed pipes. Figure
compares the analyzer position and design of KOHAT Cement and BCL Chakwal.
Page 6 of 7
7- Recommendation:
Relocation of Probe sampling point at Kiln inlet is possible. This
provides an opportunity for plant optimization. Relocation of gas
analyzer will have following key benefits.
1.
2.
3.
4.
5.
6.
References
Anis Haider ITECA. (n.d.). Presentation on Inlet Gas Analyzer.
FLSmidth. (2014). Kiln Inlet Analyzer Presentation .
Office, G. A. (2008). Kohat and Gharibwal Cement