Вы находитесь на странице: 1из 5

Name of Project:

Job No.:
Client:
Designed by:
Date:

hhghh
hhghh
yyy
uuu
tyyuy

General Notes:
gkg
uyuu
hgh
Sheet:

Jerv Works Const.


*Input data in green cells

Of

Ref: Reinforced Concrete Design, pg.416 by: Besavilla

Footing, square
footing no.

ghh

specification
fc'
fy
wt. of concrete
earth unit weight
q, allowable soil pressure

20
400
23.5
15.7
170

service load
service Dead load
service Live load

900 kN
1600 kN

MPa
MPa
kN/m3
kN/m3
kPa

column
h
b

480 mm
480 mm

footing
assume L
assume footing h (min. .20m)
concrete cover

OK
4.2 m2 > = 4.2
0.8 m.
70 mm

overburden

0.6 m

R-bars to use
Phils. Standard Reinforcing Bars

footing reinforcement

r-bar
25mm

column dowels

r-bar
25mm

no.
4

min. 4

Results:
OK - soil pressure
OK - 2-way shear
OK - beam shear
OK - ld of reinforcement
OK - bearing load of column to footing
OK - no. of column dowels
use ld min 400 mm into both column and footing

OK - soil pressure
OK - footing depth but may lessen by 5.68%

480 mm

4.2 m

480 mm

15 - 25mm e.w.

0.6 m. overburden
15 - 25mm e.w.
0.8 m

4.2 m

solution
wt. of assume footing
wt. of overburden
total load = wt. of footing +overburden+ column load
required footing area = total load / q
required footing L =
actual footing L
actual footing area
Pu = 1.4(DL+overburden) + 1.7LL
qu, actual upward soil pressure = Pu/actual foot. area
qa ,allowable value of soil pressure = q* Pu /(DL + LL)

331.632
163.9984
2995.63
17.62136
4.2
4.2
17.64
4209.598
238.6393

kN
kN
kN
m2
m
m
m2
kN
kPa

286.2527 kPa >>==


OK - soil pressure

check d by punching shear


actual d =
min c =

692.5 mm
480 mm
d/2

d/2

238.6393

L
actual punching shear, vn = Vu/bod
actual Vu =qu* [L2 - (c+d)2]
actual shear vc = Vu / bod

3881.527 kN
1406.019 kPa

allowable punching shear


c = long side of column / short side of column
allowable punching shear, vc = (1+2/c)fc'/6
allowable punching shear = fc'/3
use min. vc =

1
2236.068 kPa
1490.712 kPa
1490.712 kPa >> == 1406.019
OK - 2-way shear
OK - footing depth but may lessen by
5.68

%
check for beam shear
actual beam shear
r = L/2-c/2-d
Vu = qu*L*r
vn = Vu/Ld

1.1675 m
1170.168 kN
473.3258 kPa

allowable beam shear


va = 1/6fc'

745.356 kPa >>==


OK - beam shear
36.5

d
r

c/2

L
Bending moment
x

473.3258

x=( L-c)/2
actual bending moment Mu = qu*L*x2/2
Mn = Mu/.90
m = fy/.85fc'
Rn = Mn/Ld2
= 1/m(1-1-2mfRn/fy)
As = (actual L*d)
no. of bars

1.86
1733.753
1926.392
23.52941
956.4359
0.002462
7161.964
15

check ld
required ld = .02Ab*fy/fc'
or ld = .06dbfy
required ld =

879.9375 mm
600 mm
879.9375 mm

actual ld = x - concrete cover

check bearing stress of footing


allowable = *.85fc'A1(A2/A1) ACI Code
A1 area column =
A2 area of square footing at center strip
(A2/A1) =
or max (A2/A1) =
required (A2/A1)
=
allowable = *.85fc'A1(A2/A1) ACI Code
actual bearing load = 1.4DL + 1.7LL
required min area of dowels = .005*area column
actual area of dowels
4 - 25mm

m
kN-m
kN-m
kPa
mm2
ea.

1790 mm >>== 879.9375


OK - ld of reinforcement

0.2304 m2
17.64 m2
8.75
2
2
0.7
5483.52 kN
3980 kN <<==
5483.52
OK - bearing load of column to footing
1152 mm2
1967.6 mm2 >>==
1152
OK - no. of column dowels

check development length of dowels (in compression)


min. Ld = .04db*fy
400 mm
or min = 200 (ACI 318-83 Section 12-3-1)
200 mm
Ld = db/4(fy/fc')
559.017 mm
required Ld = Ld(As required/ As actual)
327.296 mm
hence, required min Ld =
400 mm
use ld min 400 mm into both column and footing

Phils. Standard Reinforcing Bars

Phils. Standard Reinforcing Bars

r-bar
6mm

r-bar
6mm

area
28.27

dia.
6

area
28.27

dia.
6

10mm
12mm
16mm
20mm
25mm
28mm
32mm

78.54
113.10
201.1
314.2
491.90
615.75
804.25
491.90

10
12
16
20
25
28
32
25

ASTM Standard Reinforcing Bars


Phils. Standard Reinforcing Bars

10mm
12mm
16mm
20mm
25mm
28mm
32mm

78.54
113.10
201.1
314.2
491.90
615.75
804.25
491.90

10
12
16
20
25
28
32
25

Вам также может понравиться