Вы находитесь на странице: 1из 2

Applionces

nsto llotion ! nstructions

Moin Boord WR55X109 42


Single Evoporotor ond Single Speed Compressor Models
Note: Do not use on duol evoporotor or vorioble speed inverter compressor models.
TOOLS YOU WILL NEED:

BEFORE YOU BEGIN


Reod these instructions completelg ond corefullg.

Disconnect power to the refrigerotor before beginning instollotion.

STEP I-REMOVE EXIST!NG MAIN BOARD

power cord

Remove bock ponel.

tl/+" Nut driver

wire cutters (for some models)

PARTS INCLUDED:

AWARNING

. Unplug

E
E

fVoin boord with ottoched ground wire

lnstollotion lnstructions

STEP 2-ELIMINATE THERMISTOR WIRE


IN PIN 2 OF J1 CONNECTOR
(See note belowl lF NO WIRE

lN

PIN 2, PROCEED TO STEP 3

--o

!!0

o.

NOTE: This step is ONLY opplicoble for the following


models:

All BOTTOM FREEZER models


ENCODER models

. After removing the bock

ponel, the electricol connections

LF?,MF?, RF2, SFz

will be visible.

GentlU pull

. Eliminote

on eoch

connector to
disconnect
from the
terminol.

. Remove
boord.

l:r

f6l'.)
v/
l\r/

tl .
t#'

thermistor
wire in pin 2 of
J1 connector.
Wire mog

originote from
o molded plug
or jumper os
shown.

Originol Boqrd connected In unit

imoginotion of work

with the following seriol number

prefi xes: TDz, VD?, ZO2, AF?, DFz, FFz, GFZ, HFz,

9-Prong Connector

. lf the copocitor

STEP 3-INSTALL NEW MAIN BOARD

. Reconnect the electricol connections bg gentlg pushing

the

connectors onto the terminols.


. The connectors on the new boord mog be in o different orderl
ploce thon the old boord.
. When replocing bock ponel, moke certoin to copture egelet of

is not present, skip to Step 5.


Cut the green wire coming from the connector to the plostic
housing (see illustrotions below).

Plostic housing before cutting green wire.

ground wire with bock ponel screw.


Moke sure the ground wire is not pinched bg the bock ponel
ond is within the enclosure.
Moke Sure G
Wire is Within
the Enclosure

Housing

White
Wire

Cut Green

Wire ot Ends

Plostic housing ofter green wire hos been cut ond removed.

STEP 4-CUT GREEN W!RE IN CAPACITOR


BOARD
Note: Onlg opplicoble for BOTTOM FREEZER models

.
.

Remove the mochine comportment occess cover.


Locote the copocitor boord in the plostic housing.

STEP 5-CHECK OPERATION

. Ensure thot
Power Cord

the unit is operoting properlg. Moke sure the


compressor ond evoporotor fon turn on. Check thot the
temperoture boord is functioning.

Copocitor

z---r Plostic

I\--l I Housino
r -.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE


GE Consumer &

lndustriol

Generol Electric Compong


Louisville, Kentuckg 40225

@ 2007 Generol Electric Compong


Pub. No. 31-45417

ge.com