Вы находитесь на странице: 1из 62

Catalog HY15-3502/US

Proportional Valves
DESCRIPTION

FLOW
LPM/GPM

PRESSURE
BAR/PSI

PAGE NO.

PRESSURE RELIEVING
AP01B2YP ........ 2G ............... Increase Pressure/Increase Current .............. 5.3/1.4 ...... 350/5000 .............. PV7-PV8
AP02B2YP ........ C08-2 .......... Increase Pressure/Increase Current .............. 5.3/1.4 ...... 350/5000 ............ PV9-PV10
AP04G2YP ........ C10-2 .......... Increase Pressure/Increase Current ................ 45/12 ...... 350/5000 .......... PV11-PV12

AP01B2YR ........ 2G ............... Decrease Pressure/Increase Current ............. 5.3/1.4 ...... 350/5000 .......... PV13-PV14
AP02B2YR ........ C08-2 .......... Decrease Pressure/Increase Current ............. 5.3/1.4 ...... 350/5000 .......... PV15-PV16
AP04G2YR ....... C10-2 .......... Decrease Pressure/Increase Current ............... 95/25 ...... 350/5000 .......... PV17-PV18

CV
Check
Valves

CAVITY

SH
Shuttle
Valves

SERIES

LM
Load/Motor
Controls

Contents

LE
Logic
Elements

FLOW CONTROLS, 2-Way


DF122C ............. C12-2 .......... Flow Control, N.C. ........................................... 53/14 ...... 210/3000 .......... PV25-PV26

PC
Pressure
Controls

PRESSURE REDUCING
GP01 30 ........... 54-1 ............ Pressure Reducing Valve ................................ 1.9/.5 ...... 210/3000 .......... PV19-PV20
GTP02 34 ......... C08-3 .......... Pressure Reducing Valve .................................. 19/5 ...... 210/3000 .......... PV21-PV22
GTP04 34 ......... 3X ............... Pressure Reducing Valve .................................. 30/8 ...... 210/3000 .......... PV23-PV24

Flow
Controls

FC

FLOW CONTROLS, 3-WAY


JP04C 31 .......... 4C ............... Priority Flow Control, N.C. ................................. 30/8 ...... 210/3000 .......... PV51-PV52
DFA125C31 ...... C12-4L ........ Priority Flow Control, N.C. ............................ 56.8/15 ...... 210/3000 .......... PV53-PV54

DIRECTIONAL CONTROL
GP02 51 ........... C08-4 .......... 4 Way, 3 Pos - Closed Center ......................... 21/5.5 ...... 350/5000 .......... PV55-PV56
GP02 53 ........... C08-4 .......... 4 Way, 3 Pos - Float Center ............................ 17/4.5 ...... 350/5000 .......... PV57-PV58

Directional
Controls
Manual
Valves

Solenoid
Valves

...... 210/3000 .......... PV41-PV42


...... 210/3000 .......... PV43-PV44
...... 210/3000 .......... PV45-PV46
...... 210/3000 .......... PV47-PV48
...... 210/3000 .......... PV49-PV50

SV

PV
Proportional
Valves

HP02P .............. 2X ............... Flow Control, N.O. ............................................. 19/5


JP02P ............... C08-3 .......... Flow Control, N.O. ............................................. 19/5
HP04P .............. C10-2 .......... Flow Control, N.O. ............................................. 30/8
JP04P ............... 3X ............... Flow Control, N.O. .......................................... 36/9.5
DF122N ............ C12-2 .......... Flow Control, N.O. ........................................... 53/14

MV

CE
Coils &
Electronics

HP02C .............. 2X ............... Flow Control, N.C. ............................................. 23/6 ...... 210/3000 .......... PV31-PV32
JP02C ............... C08-3 .......... Flow Control, N.C. ............................................. 23/6 ...... 210/3000 .......... PV33-PV34
HP04C .............. C10-2 .......... Flow Control, N.C. .......................................... 36/9.5 ...... 210/3000 .......... PV35-PV36
JP04C 21 .......... 3X ............... Flow Control, N.C. .......................................... 36/9.5 ...... 210/3000 .......... PV37-PV38
DFA125C21* .... C12-3L ........ Flow Control, N.C. ........................................ 56.8/15 ...... 210/3000 .......... PV39-PV40
*The DFA125C21 will be available January 1, 2011.

DC

BC
Bodies &
Cavities

DF161C ............. C16-2 .......... Flow Control, N.C. ......................................... 150/40 ...... 210/3000 .......... PV27-PV28
DF201C ............. C20-2 .......... Flow Control, N.C. ......................................... 325/60 ...... 210/3000 .......... PV29-PV30

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Technical
Data

TD
DSP105C1 ........ C10-4 .......... 4 Way, 3 Pos - Closed Center ......................... 32/8.5 ...... 210/3000 .......... PV59-PV61
DSP105C4 ........ C10-4 .......... 4 Way, 3 Pos - Float Center ............................ 32/8.5 ...... 210/3000 .......... PV59-PV61

Catalog HY15-3502/US

Technical Tips

Proportional Control Valves

CV

INTRODUCTION
Check
Valves

SH

This technical tips section is designed to help familiarize you with the Parker line of Proportional Valves. In this
section we present common options, technical terms, as well as a brief synopsis of the operation and applications
of the various products offered in this section. The intent of this section is to help you in selecting the best
products for your application.

Shuttle
Valves

LM
Load/Motor
Controls

COMMON OPTIONS
As you will see, Parker offers a variety of Proportional Valve products. As such, some of the options mentioned
below may not be available on all valves. Consult the model coding and dimensions for each valve for specifics.
Here are some of the common options available.

FC
Flow
Controls

PC
Pressure
Controls

Seals: The majority of the products are available in


Nitrile or Fluorocarbon Seals. The Winners Circle
products feature a standard 4301 Polyurethane
D-Ring. The D-Ring eliminates the need for backup
rings. You should match the seal compatibility to the
temperature and fluid being used in your application.

Overrides: Overrides are standard on many of the


Parker proportional valves. The override is generally a
push type that is flush with the end of the tube. Consult
the individual catalog pages for more details.

LE
Logic
Elements

DC
Directional
Controls

MV
Manual
Valves

SV
Solenoid
Valves

PV
Proportional
Valves

CE
Coils &
Electronics

BC
Bodies &
Cavities

TD

TECHNICAL TERMS
To help in applying our proportional valve line of
product, we have listed some technical terms below,
as well as some helpful hints in applying our valves.

Ohms Law: Electrical current is generated as a result


of the relationship between input voltage and the
resistance to the flow of electrical current. It is
represented in equation form by I = V/R (or V=IR),
where I is current, V is voltage and R is resistance.
This is an important relationship to remember when
dealing with any electrically operated valves.
Proportional valves allow varying control of flow or
pressure, dependant on the current signal provided.
As coils heat up, their resistance rises. This means a
higher voltage must be available to maintain the same
amount of pressure or flow. Thus, the application
needs to be designed such that the full on position is
about 70% of the initial current draw. On the individual
catalog pages a maximum control current is specified
to help in applying our proportional valves.
PWM: Pulse Width Modulation (PWM) is the preferred
signal for controlling electrical current. PWM is on / off
voltage in a square wave form. The percent on time
or duty cycle provides the average voltage. The valve
driver adjusts the duty cycle to obtain current control.
We recommend valve drivers with current control for
optimum performance. PWM signals also usually
provide dither for the proportional valve. Dither is a

small back and forth movement of the valve spool


around its set position. This rapid movement reduces
the friction of the valve and leads to faster, more
accurate response.

PWM Frequency: The frequency of a PWM signal is


the rate at which the signal is turned on and off.
Parkers analog proportional valves are designed to
work with low frequency responses between 100-400
Hz. The performance curves on our catalog pages
were performed with a PWM signal at 200 Hz.
Hysteresis: Due to various factors, the performance
of a proportional valve will show a slightly different
performance when the current signal is increasing than
it will when the signal is being decreased. This
difference is usually expressed as a percentage of
total input change and is referred to as the hysteresis
of the valve.
Deadband: Cracking or deadband refers to the
amount of the control signal that is needed to produce
any movement of the spool. Thus, a 20% deadband
means that 20% of the control signal is needed before
the spool will move.

Technical
Data

PV1

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Tips

Proportional Control Valves


CV

Normally Closed
Proportional Flow Control

Shuttle
Valves

Proportional Flow Control Valve


Proportional flow control valves provide pseudo pressure compensation and are used on systems requiring
variable electronic control of flow. They allow the operator to vary the control signal to accelerate or decelerate an
actuator. A compensator valve can be added to the circuit for enhanced compensation. Some typical applications
would include the hoist control for a lift, or the speed control for a winch circuit. Parker offers both normally closed
and normally open versions of proportional flow controls.

SH

LM
Load/Motor
Controls

Proportional valves are nothing more than electrically adjustable hydraulic valves. They give the operator nearly
infinite adjustment control and flexibility. Parker Hannifin offers various types of proportional flow control, pressure
reducing, and relief valves.

Check
Valves

PRODUCT TYPES / APPLICATIONS

Out (2)

OPERATION - With the solenoid


coil de-energized, the spool is held in
an open position by spring force; allowing full flow
to pass. As the solenoid coil is energized, the spool
begins to move away from a full open position;
allowing less flow to pass. Once a full electronic signal is given, the spool is held in a closed position; allowing no
flow to pass. As the electronic signal is then reduced, the spool begins to open; allowing flow to pass again. Once
a constant electronic signal is given, the spool is held in that position by a balance between electronic force and
spring force. Pseudo compensation is obtained by the pressure drop across the orifices in the spool.

Directional
Controls

DC

In
(1)

Normally Closed
Proportional Needle Valve
The proportional needle valves
are electronic controlled variable
needle valves. They are designed
specifically for bleed off or unloading
circuits as back pressure will affect performance.

LE

MV
Manual
Valves

Normally Open
Proportional Flow Control

PC
Pressure
Controls

OPERATION - With the solenoid


Port (1)
coil de-energized, the spool is held in
Is Not Used
a closed position by the spring force. When the
solenoid coil is energized, the amperage of the
signal moves the spool into an open position.
The spool is held in this position by a balance between spring force and electrical force. As the current increases,
the spools opens further; allowing more flow. As the current decreases, the spool begins closing; allowing less
flow. Pseudo compensation is obtained by the pressure drop across the orifices in the spool.

Logic
Elements

(3)

SV
Solenoid
Valves

(2)

Flow
Controls

FC

Proportional
Valves

PV

Outlet
(1)

BC
Bodies &
Cavities

Inlet (2)
OPERATION - With the solenoid de-energized, the main
poppet is held in the closed position by spring force. When
the solenoid is energized, the sensing spool moves into a partially open position relative to the percentage of
rated current flowing through the coil. This action allows the main poppet to move away from the valve seat to a
degree that corresponds to sensing spool position. The valve will maintain a fixed amount of opening as long as
the electrical current remains constant and will vary proportionally with an increase or decrease in current.

Coils &
Electronics

CE

Technical
Data

TD

PV2

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Tips

Proportional Control Valves

CV
Check
Valves

SH
Shuttle
Valves

LM
Load/Motor
Controls

FC
Flow
Controls

PC
Pressure
Controls

LE
Logic
Elements

DC
Directional
Controls

MV

Proportional Priority
Bypass Flow Control
Reg.
Bypass Inlet
(3)
(4)
The proportional priority bypass
(2)
flow controls allow electronic
Not Used
(1)
control of the flow setting for the
priority flow circuit. The priority
flow remains constant regardless of
changes in load or pressure. The excess inlet flow is diverted
or bypassed to tank. The bypass port must not have any restrictions or performance will be hindered.
OPERATION - Flow enters the valve through port 3. With the coil de-energized, flow is bypassed to port 2. When
the coil is energized, the internal orifice is increased allowing pressure compensated flow to the priority port (port
4). The excess flow is bypassed to port 2. As input current is increased, the priority flow increases and the bypass
flow decreases. As the current is decreased, priority flow decreases and bypass flow is increased.

Direct Acting,
Normally Closed Proportional
Pressure Reducing Valve
T (1)
Direct acting, normally closed
proportional pressure reducing
valves are used to electronically reduce the inlet
Act. (2) (3) P
pressure to one leg of a hydraulic circuit. This valve is used
when a fixed regulated pressure is required regardless of the inlet pressure. This valve could be used as a clutch
control for power shift transmissions and PTO, or as a pilot control for directional control valves.

Manual
Valves

OPERATION - With the solenoid coil de-energized, the spool is held in a closed position by spring force. In this
mode, the regulated pressure port is open to tank and the pressure inlet is blocked. As current is applied to the
solenoid coil, the spool will begin to travel to a position where the pressure inlet port is connected to the regulated
pressure port. At this point, reduced pressure becomes a function of the current signal. As long as the current
signal is constant, the reduced pressure at the regulated pressure port will remain fixed regardless of any
changes in inlet flow or inlet pressure. As the current signal increases or decreases, the reduced pressure at the
regulated pressure port will change with respect to the changes in signal. Once the coil is fully energized, the
reduced pressure of the regulated pressure port will be at the maximum reduced pressure for that valve.

SV
Solenoid
Valves

PV
Proportional
Valves

CE
Coils &
Electronics

BC
Bodies &
Cavities

TD
Technical
Data

PV3

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Tips

Proportional Control Valves

Direct Acting

Check
Valves

CV

SH
Shuttle
Valves

Normally Closed Proportional Pressure Reducing / Relieving Valve


Normally Closed Proportional Pressure Reducing/Relieving Valves are used to electronically reduce the inlet pressure to one leg of a hydraulic circuit. In addition these valves act as a relief valve, relieving any shocks or surges
that occur between its regulating port and the actuator. Parker offers direct acting and pilot operated versions of
this valve. The direct acting valves are faster responding and generally have lower hysteresis, but are limited to
smaller reduced pressures (generally below 800 psi depending on the valve.) Pilot operated are generally slower
on response due to the two stage performance, but can have a reduced pressure as high as 3000 psi.

Flow
Controls
Pressure
Controls
Logic
Elements

LE

DC
Directional
Controls

OPERATION - With the solenoid


In (2)
(3) Tank
coil de-energized, the pilot dart is
held open by the spring force. This
Reg.
(1)
allows the main spool to close and restricts flow from
going from the inlet (2) port to the regulated port (1).
As the electronic signal is applied to the coil, the pilot dart
is moved towards the pilot seat restricting pilot flow. This
restriction raises the effective pressure inside the chamber between the spool and the pilot seat, allowing the
spool to travel away from the pilot seat to a position where the pressure at inlet (2) is connected to the regulated
pressure port (1). At this point, reduced pressure becomes a function of the electronic signal. As long as the
electronic signal is constant, the reduced pressure at the regulated pressure port (2) will remain fixed regardless
of any changes in inlet flow or inlet pressure. As the electronic signal increases or decreases, the reduced
pressure at port (1) will change with respect to the change in the electronic signal.

PC

MV
Manual
Valves

Pilot Operated

FC

SV
Solenoid
Valves

OPERATION - With the solenoid


Pressure (2)
(3) Tank
coil de-energized, the spool is held
Reg.
in a closed position by spring force.
(1)
In this mode, the regulated pressure port is open to tank
and the pressure inlet port is blocked. As an electronic
signal is applied to the solenoid coil, the spool will begin
to travel to a position where the pressure inlet port is connected to the regulated pressure port. At this point,
reduced pressure becomes a function of the voltage signal. As long as the electronic signal is constant, the
reduced pressure at the regulated pressure port will remain fixed regardless of any changes in inlet flow or inlet
pressure. As the electronic signal increases or decreases, the reduced pressure at the regulated port will change
with respect to the change in electronic signal. Once a full signal is given, the reduced pressure of the regulated
pressure port will be at the maximum reduced pressure for that valve.

Load/Motor
Controls

LM

Proportional
Valves

PV

Coils &
Electronics

CE

Bodies &
Cavities

BC

Technical
Data

TD

PV4

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Tips

Proportional Control Valves

CV
Check
Valves

SH
Shuttle
Valves

LM
Load/Motor
Controls

FC

Normally Closed
Proportional Relief Valve
(2)
Normally closed proportional relief
valves are used to electronically
control the system pressure.
(1)
These valves are ideal for circuits
with varying system pressures
demands. A small flow pilot version
of the normally closed proportional relief is also offered for
piloting a larger logic element or vented relief valve. The normally
closed relief defaults to a maximum pressure setting (i.e. 3000 psi) when there is no current applied.

Flow
Controls

OPERATION - With the solenoid coil de-energized, the pilot dart is held closed by the spring. As current is applied
to the coil, the pilot dart is moved creating less restriction of the pilot flow. As this restriction is reduced with the
increasing current, the pressure setting also decreases. Once a constant electronic signal is given, the pilot dart is
held in a given position, holding the pressure setting. This is maintained by the balance between the electronic
spring force and the inlet pressure.

PC
Pressure
Controls

LE
Logic
Elements

DC
Directional
Controls

MV
Manual
Valves

SV

Normally Open
Proportional Relief Valve
(2)
Normally open proportional relief
valves are used to electronically
(1)
control the system pressure.
These valves are ideal for circuits
with varying system pressure
demands. A small flow pilot version
of the normally open proportional relief is also offered
for piloting a larger logic element or vented relief valve. The normally open relief defaults to minimum system
pressure (i.e. 150 psi) when there is no current applied. Normally closed versions are also available upon request.

Solenoid
Valves

OPERATION - With the solenoid coil de-energized, the pilot dart is held open by the spring. This allows the main
spool to open at minimum pressure 10.4 Bar (150 psi). As current is applied to the coil, the pilot dart is moved
towards the pilot seat restricting pilot flow. This restriction raises the effective pressure setting of the valve. Once
a constant electronic signal is given, the pilot dart is held in a given position, holding the pressure setting. This is
maintained by a balance between electronic spring force and inlet pressure. As the electronic signal is reduced,
the pilot dart is moved away from the pilot seat. This lowers the effective pressure setting of the valve.

PV
Proportional
Valves

CE
Coils &
Electronics

BC
Bodies &
Cavities

TD
Technical
Data

PV5

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Bodies &
Cavities
Coils &
Electronics

Proportional
Valves

Solenoid
Valves

Manual
Valves

Directional
Controls

Logic
Elements

Pressure
Controls

Flow
Controls

Load/Motor
Controls

Shuttle
Valves

Check
Valves

Technical Tips
Notes

Technical
Data

Catalog HY15-3502/US

Proportional Control Valves


CV

SH

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV6

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Relief Valve


Series AP01B2YP 07C, 14C, 21C, 35C

CV

General Description
Check
Valves

SH

Proportional Relief Valve. Increasing Pressure With


Increasing Current. For additional information see
Technical Tips on pages PV1-PV6.

LM

Analog Proportional Relief Valve regulates pressure


proportionally to the solenoid current

Direct acting poppet design

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Load/Motor
Controls

Shuttle
Valves

Features

FC

One piece cartridge housing ensures internal


concentricity

(2)

Flow
Controls

(1)

(1)

(2)

PC

Logic
Elements

Rated Flow
(At 70 PSI P)

DC
Directional
Controls

Max. Pressure At
Port 1 @ 75%
Input Current

MV
Manual
Valves

SV

Hysteresis @
200 Hz PWM
Cracking
Pressure

Solenoid
Valves

PV

Cartridge Material

Proportional
Valves

Operating Temp.
Range/Seals

CE

07C
14C
21C
35C

5.3 LPM (1.4 GPM)


3.4 LPM (0.9 GPM)
3.0 LPM (0.8 GPM)
1.3 LPM (.35 GPM)

07C
14C
21C
35C

70 Bar (1000 PSI)


140 Bar (2000 PSI)
210 Bar (3000 PSI)
350 Bar (5000 PSI)

Performance Curves
PWM Current Regulator Recommended
Pressure Drop vs. Flow
Measured at
De-energized coil

5%

07C
14C
21C
35C

.07 Bar (1 PSI)


.14 Bar (2 PSI)
.21 Bar (3 PSI)
.35 Bar (4 PSI)

Coils &
Electronics

Filtration

ISO Code 16/13,


SAE Class 4 or better

120

8.6

80

5.7

40

2.0

-21

Bodies &
Cavities

Cavity

2G
(See BC Section for more details)

1.5

2.3

3.0

3.8

4.5

5.3

0.2

0.4

0.6

0.8

1.0

1.2

1.4

Flow (Q)

Measured at coil stabilized


temperature and nominal flow

-35

4000 274
-21

3000 205
-14

2000 137
-07

1000

68
0
0

.06 kg (.14 lbs.)

0.8

Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
5000 345

BC

Approx. Weight

-07

-14

Pressure vs. Input Signal (Current)

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)
Mineral-based or synthetic with
lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

-35

160 11.4

0
LPM
0
GPM

All parts steel. All operating


parts hardened steel.

Fluid
Compatibility/
Viscosity

Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
200 14.3

Pressure Drop ( P)

Specifications

Pressure

Pressure
Controls

LE

20

40

60

80

Current (%)

TD
Technical
Data

PV7

Parker Hannifin Corporation


Hydraulic Cartridge Systems

100

Proportional Relief Valve


Series AP01B2YP 07C, 14C, 21C, 35C

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)
Check
Valves

Dimensions

62.7
(2.47)

SH

5/8 Hex.
4.1 Nm
(3 lb. ft.)
Torque

LM
Load/Motor
Controls

33.8
(1.33)

XXVDC XXW
CCX XXX H

See Super Coil


1/2" I.D.
Information For
Terminal Connectors

75.7
(2.98)

FC
Flow
Controls

PAT.XXXXXXX
MADEINU.S.A.

39.6
(1.56)

Shuttle
Valves

19.8
(0.78)

3/4 Hex.
24 Nm (18 lb. ft.)
Torque
(2)

12.7
(0.50)

PC

5/8-18 UNF

Pressure
Controls

17.9
(0.70)

(1)

NOTE: Requires 2G Cavity

Logic
Elements

LE

Ordering Information

MV

Code Style (Maximum


Relief Pressure)

Coil
Type

Code Seals / Kit No.


N

07C 70 Bar (1000 PSI)


14C 140 Bar (2000 PSI)

21C 210 Bar (3000 PSI)


E

35C 350 Bar (5000 PSI)

Nitrile / Buna-N (Std.)


(SK30129N-1)
Fluorocarbon /
(SK30129V-1)
Ethylene Propylene

Custom pressure setting available.


Consult factory.

Coil
Voltage

Coil
Termination

Code Coil Type

Code Coil Termination

Omit Without Coil

Omit Without Coil

SP

Super Coil - 19 Watts

D
A

DIN Plug Face


Amp Jr. Timer*

Code Coil Voltage

Dual Lead Wire*

Omit Without Coil


D012 12 VDC

LS
H

Sealed Lead Wire*


Molded Deutsch*

D024 24 VDC

See Super Coil 1/2 I.D.


*DC Only

SV
Solenoid
Valves

Seals

PV
Proportional
Valves

Style

Manual
Valves

AP01B2YP
08 Size
Proportional
Relief Valve

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

Coils &
Electronics

CE

BC

Body Material

Bodies &
Cavities

Order Bodies Separately

Code Body Material

TD

Line Body
Code Porting

Porting

324 1/4 SAE

Aluminum

325 1/4 BSP

Steel

Technical
Data

LB10

PV8

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Relief Valve


Series AP02B2YP 07C, 14C, 21C, 35C

CV

General Description

Load/Motor
Controls

FC
Flow
Controls

PC
Pressure
Controls

LE

Analog Proportional Relief Valve regulates pressure


proportionally to the solenoid current

Direct acting poppet design

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

One piece cartridge housing ensures internal


concentricity

(1)

Specifications

Logic
Elements

Rated Flow
(At 70 PSI P)

Directional
Controls

Max. Pressure At
Port 1 @ 75%
Input Current

MV
Manual
Valves

Hysteresis @
200 Hz PWM
Cracking
Pressure

Solenoid
Valves

PV

(2)

(1)

NOTE:
This valve will be available January 1, 2011.

DC

SV

(2)

Cartridge Material

Proportional
Valves

Operating Temp.
Range/Seals

CE

07C
14C
21C
35C

5.3 LPM (1.4 GPM)


3.4 LPM (0.9 GPM)
3.0 LPM (0.8 GPM)
1.3 LPM (.35 GPM)

07C
14C
21C
35C

70 Bar (1000 PSI)


140 Bar (2000 PSI)
210 Bar (3000 PSI)
350 Bar (5000 PSI)

Performance Curves
PWM Current Regulator Recommended
Pressure Drop vs. Flow
Measured at
De-energized coil

5%

07C
14C
21C
35C

.07 Bar (1 PSI)


.14 Bar (2 PSI)
.21 Bar (3 PSI)
.35 Bar (4 PSI)

Coils &
Electronics

Filtration

ISO Code 16/13,


SAE Class 4 or better

120

8.6

80

5.7

40

2.0

-21

Bodies &
Cavities

Cavity

C08-2
(See BC Section for more details)

1.5

2.3

3.0

3.8

4.5

5.3

0.2

0.4

0.6

0.8

1.0

1.2

1.4

Flow (Q)

Measured at coil stabilized


temperature and nominal flow

-35

4000 274
-21

3000 205
-14

2000 137
-07

1000

68
0
0

.06 kg (.14 lbs.)

0.8

Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
5000 345

BC

Approx. Weight

-07

-14

Pressure vs. Input Signal (Current)

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)
Mineral-based or synthetic with
lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

-35

160 11.4

0
LPM
0
GPM

All parts steel. All operating


parts hardened steel.

Fluid
Compatibility/
Viscosity

Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
200 14.3

Pressure Drop ( P)

Shuttle
Valves

LM

Features

Pressure

Check
Valves

SH

Proportional Relief Valve. Increasing Pressure With


Increasing Current. For additional information see
Technical Tips on pages PV1-PV6.

20

40

60

80

Current (%)

TD
Technical
Data

PV9

Parker Hannifin Corporation


Hydraulic Cartridge Systems

100

Proportional Relief Valve


Series AP02B2YP 07C, 14C, 21C, 35C

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)
Check
Valves

Dimensions

5/8 Hex.
4.1 Nm
(3 lb. ft.)
Torque

33.8
(1.33)

See Super Coil


1/2" I.D.
Information For
Terminal Connectors

FC

(2)

Flow
Controls

7/8 Hex.
30 Nm (22 lb. ft.)
Torque
3/4-16 UNF-2A
Thread

PC
Pressure
Controls

27.8
(1.10)

(1)

12.6
(0.50)

Load/Motor
Controls

85.8
(3.38)

LM

XXVDC XXW
CCX XXX H

PAT.XXXXXXX
MADEINU.S.A.

39.5
(1.56)

19.8
(0.78)

Shuttle
Valves

SH
62.7
(2.47)

Logic
Elements

LE

Omit D-Ring / (SK08-2)

07C 70 Bar (1000 PSI)


14C 140 Bar (2000 PSI)

Nitrile / Buna-N (Std.)


(SK08-2N)

21C 210 Bar (3000 PSI)

Fluorocarbon /
(SK08-2V)

35C 350 Bar (5000 PSI)


Custom pressure setting available.
Consult factory.

Code Coil Type


Omit Without Coil
SP Super Coil - 19 Watts

Coil
Termination

Body
Material

Port
Size

Code Coil Voltage

Code Body Material

Omit Without Coil

Omit Steel

D012 12 VDC
D024 24 VDC

Aluminum

Code Port Size


Code Coil Termination
Omit Without Coil
D

DIN Plug Face

A
L

Amp Jr. Timer*


Dual Lead Wire*

LS

Sealed Lead Wire*

Molded Deutsch*

Body Part No.

Omit Cartridge Only


4T SAE-4
(B08-2-*4T)
6T SAE-6
(B08-2-*6T)
6B

SV
Solenoid
Valves

Code Seals / Kit No.

Coil
Voltage

3/8 BSPG (B08-2-*6B)

* Add A for aluminum, omit for steel.

See Super Coil 1/2 I.D.


*DC Only

PV
Proportional
Valves

Coil
Type

CE

BC
Bodies &
Cavities

Code Style (Maximum


Relief Pressure)

Seals

MV

TD
Technical
Data

Style

NOTE:
This valve will be available
January 1, 2011.

Coils &
Electronics

AP02B2YP

Manual
Valves

Ordering Information

08 Size
Proportional
Relief Valve

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

PV10

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Relief Valve


Series AP04G2YP 10C, 21C, 35C

Catalog HY15-3502/US

Technical Information
CV

General Description
Check
Valves

SH
Shuttle
Valves

LM
Load/Motor
Controls

FC

Proportional Relief Valve. Increasing Pressure With


Increasing Current. For additional information see
Technical Tips on pages PV1-PV6.

Features

Flow
Controls

Pilot operated spool-type design fits industry common


cavity (10-2)
Relieving pressure output is proportional to DC current
input

Precise setting of factory preset pressure in energized


mode
One piece cartridge housing ensures internal
concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
affecting performance.

(1)

(2)
(2)

PC

Logic
Elements

DC

(1)

Directional
Controls

Rated Flow
(At 300 PSI P)
When Coil is Fully
De-Energized

95 LPM (25 GPM)

Factory Set Relief


Pressure When
Coil De-Energized
Measured at
45 LPM (12 GPM)

10C
21C
35C

Performance Curves
PWM Current Regulator Recommended
Relief Performance

103 Bar (1500 PSI)


210 Bar (3000 PSI)
350 Bar (5000 PSI)

PSI

Hydraulic Oil 150 SSU @ 100F (32 cSt)

Bar

5000 345
-35

Pressure Drop ( P)

Pressure
Controls

LE

Specifications

4000 274
3000 205

Manual
Valves

SV
Solenoid
Valves

PV

Hysteresis @
250 Hz PWM

< 7%
of Maximum Pressure Setting

Proportional
Valves

Response Time At
75% of Nominal
Voltage Change
(Measured To 90%
of Press. Change)

To Unload
To Load
10C
21C
35C

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

CE

10ms

-21

-10

1000
300

45 ms
60 ms
80 ms

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Coils &
Electronics

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Bodies &
Cavities

.14 kg (.31 lbs.)

Cavity

C10-2
(See BC Section for more details)

68
21
0
LPM
0
GPM

Coil De-Energized

19

38

57

76

95

10

15

20

25

Flow (Q)

Pressure vs. Input Current


PSI Bar
5000 345

Hydraulic Oil 150 SSU @ 100F (32 cSt)


Measured at coil stabilized
temperature and nominal flow

-35

4000 274
-21

3000 205
2000 137
1000

BC

Approx. Weight

Coil Fully Energized

2000 137

Pressure

MV

-10

68
0
12V
0
24V

.30

.60

.90

1.20

.15

.30

.45

.60

Current, Amp

TD
Technical
Data

PV11

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Relief Valve


Series AP04G2YP 10C, 21C, 35C

Catalog HY15-3502/US

Technical Information

CV

Dimensions

Check
Valves

Millimeters (Inches)

62.7
(2.47)

SH

See Super Coil


1/2" I.D.
Information For
Terminal Connectors

FC
Flow
Controls

10.0
(0.40)

1 Hex.
34 Nm (25 lb. ft.)
Torque
31.8
(1.25)

PC
Pressure
Controls

7/8-14 UNF
(2)

LE

(1)

Logic
Elements

15.8
(0.62)

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

Ordering Information

MV

35C 350 Bar (5000 PSI)


Custom pressure setting available.
Consult factory.

Code Seals / Kit. No.


N

Nitrile / Buna-N (Std.)


(SK30503N-1)

Fluorocarbon /
(SK30503V-1)

Coil
Voltage

Coil
Termination

Body
Material

Port
Size

Code Coil Termination

Code Body Material

Omit Without Coil

Omit Without Coil

Omit Steel

SP

Super Coil - 19 Watts

D
A

DIN Plug Face


Amp Jr. Timer*

Code Coil Voltage

Dual Lead Wire*

Code Port Size

Omit Without Coil


D012 12 VDC

LS
H

Sealed Lead Wire*


Molded Deutsch*

Omit
4P
6P
8P
6T
8T
T8T

Cartridge Only
1/4 NPTF (B10-2-*4P)
3/8 NPTF (B10-2-*6P)
1/2 NPTF (B10-2-*8P)
SAE-6
(B10-2-*6T)
SAE-8
(B10-2-*8T)
SAE-8
(B10-2-T8T)

6B

3/8 BSPG (B10-2-*6B)

D024 24 VDC

See Super Coil 1/2 I.D.


*DC Only

SV
Solenoid
Valves

Code Coil Type

Aluminum
Body Part No.

* Add A for aluminum, omit for steel.


Steel body only.

PV
Proportional
Valves

10C 104 Bar (1500 PSI)


21C 210 Bar (3000 PSI)

Coil
Type

CE

BC
Bodies &
Cavities

Code Style (Maximum


Relief Pressure)

Seals

TD
Technical
Data

Style

Manual
Valves

AP04G2YP
10 Size
Proportional
Relief Valve

LM

Coils &
Electronics

97.6
(3.84)

XXVDC XXW
CCX XXX H

PAT.XXXXXXX
MADEINU.S.A.

39.6
(1.56)

33.8
(1.33)

Load/Motor
Controls

5/8 Hex.
4.1 Nm
(3 lb. ft.)
Torque

Shuttle
Valves

19.8
(0.78)

PV12

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Relief Valve


Series AP01B2YR 07A, 14A, 21A, 35A

CV

General Description
Check
Valves

SH

Proportional Relief Valve. Decreasing Pressure With


Increasing Current. For additional information see
Technical Tips on pages PV1-PV6.

LM

Analog Proportional Relief Valve regulates pressure


proportionally to the input solenoid current

Direct acting poppet design

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Load/Motor
Controls

Shuttle
Valves

Features

FC

One piece cartridge housing ensures internal


concentricity

Flow
Controls

(2)
(1)

(2)

(1)

PC
Pressure
Controls

Specifications

DC
Directional
Controls

MV
Manual
Valves

SV
Solenoid
Valves

PV
Proportional
Valves

CE

5.3 LPM (1.4 GPM)


3.4 LPM (0.9 GPM)
3.0 LPM (0.8 GPM)
1.9 LPM (0.5 GPM)

Relief Performance
Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
6000 414

-35A

5000 345

Factory Set Relief


Pressure When
De-Energized
(5% -Std.
2% - Low
Variation)

07A
14A
21A
35A

70 Bar (1000 PSI)


140 Bar (2000 PSI)
210 Bar (3000 PSI)
350 Bar (5000 PSI)

4000 274
-21A

3000 205
-14A

2000 137
-07A

1000

Hysteresis @
200 Hz PWM

68

< 10%

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Coils &
Electronics

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Approx. Weight

.09 kg (.19 lbs.)

BC
Bodies &
Cavities

TD

07A
14A
21A
35A

Relief Pressure

Logic
Elements

Rated Flow
(At 70 PSI P)

Performance Curves
PWM Current Regulator Recommended

0
LPM
0
GPM

1.89

2.84

3.78

.25

.50

.75

1.00

Flow (Q)

Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
5000 345

Measured at coil stabilized


temperature and nominal flow

4000 274
3000 205
2000 137
68

1000
0

Cavity

.95

Pressure vs. Input Current

Pressure

LE

20

40

60

80

Input Current (%)

2G
(See BC Section for more details)

Technical
Data

PV13

Parker Hannifin Corporation


Hydraulic Cartridge Systems

100

Proportional Relief Valve


Series AP01B2YR 07A, 14A, 21A, 35A

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)
Check
Valves

Dimensions

36.0
(1.43)

Load/Motor
Controls

84.0
(3.32)

LM

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

SH
22.0
(0.86)

Shuttle
Valves

66.5
(2.62)

25.4 Dia
(1.00)
Finger Tight
Torque

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

FC

26.0
(1.02)

(2)

Flow
Controls

3/4 Hex.
15 Nm (11 lb. ft.)
Torque
5/8-18 UNF

PC
Pressure
Controls

12.7
(0.50)

(1)

NOTE: Requires 2G Cavity

Logic
Elements

LE

Ordering Information

MV
Coil
Type

Code Seals / Kit. No.

Code Style (Maximum


Relief Pressure)

07AL 70 Bar (1000 PSI)


14AL 140 Bar (2000 PSI)

21AL 210 Bar (3000 PSI)


E

35AL 350 Bar (5000 PSI)

Nitrile / Buna-N (Std.)


(SK30129N-1)
Fluorocarbon /
(SK30129V-1)
Ethylene Propylene

Custom pressure setting available.


Consult factory.

Coil
Voltage

Coil
Termination

Code Coil Type

Code Coil Termination

Omit Without Coil

Omit Without Coil

SP

Super Coil - 28 Watts

D
A

DIN Plug Face


Amp Jr. Timer*

Code Coil Voltage

Dual Lead Wire*

Omit Without Coil


D012 12 VDC

LS
H

Sealed Lead Wire*


Molded Deutsch*

D024 24 VDC

See Super Coil 5/8 I.D.


*DC Only

SV
Solenoid
Valves

Seals

PV
Proportional
Valves

Style

Manual
Valves

AP01B2YR
08 Size
Proportional
Relief Valve

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

Coils &
Electronics

CE

BC

Body Material

Bodies &
Cavities

Order Bodies Separately

Code Body Material

TD

Line Body
Code Porting

Porting

324 1/4 SAE

Aluminum

325 1/4 BSP

Steel

Technical
Data

LB10

PV14

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Relief Valve


Series AP02B2YR 07A, 14A, 21A, 35A

CV

General Description
Check
Valves

SH

Proportional Relief Valve. Decreasing Pressure With


Increasing Current. For additional information see
Technical Tips on pages PV1-PV6.

LM

Analog Proportional Relief Valve regulates pressure


proportionally to the input solenoid current

Direct acting poppet design

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Load/Motor
Controls

Shuttle
Valves

Features

FC

One piece cartridge housing ensures internal


concentricity
(2)

Flow
Controls

(1)

(2)

(1)

PC
Pressure
Controls

Specifications

DC
Directional
Controls

MV
Manual
Valves

SV
Solenoid
Valves

PV
Proportional
Valves

CE

5.3 LPM (1.4 GPM)


3.4 LPM (0.9 GPM)
3.0 LPM (0.8 GPM)
1.9 LPM (0.5 GPM)

Relief Performance
Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
6000 414

-35A

5000 345

Factory Set Relief


Pressure When
De-Energized
(5% -Std.
2% - Low
Variation)

07A
14A
21A
35A

70 Bar (1000 PSI)


140 Bar (2000 PSI)
210 Bar (3000 PSI)
350 Bar (5000 PSI)

4000 274
-21A

3000 205
-14A

2000 137
-07A

1000

Hysteresis @
200 Hz PWM

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Coils &
Electronics

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Bodies &
Cavities

Approx. Weight

68

< 10%

Cartridge Material

BC

TD

07A
14A
21A
35A

Relief Pressure

Logic
Elements

Rated Flow
(At 70 PSI P)

Performance Curves
PWM Current Regulator Recommended

0
LPM
0
GPM

1.89

2.84

3.78

.25

.50

.75

1.00

Flow (Q)

Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
5000 345

Measured at coil stabilized


temperature and nominal flow

4000 274
3000 205
2000 137
1000

68
0

.09 kg (.19 lbs.)

Cavity

.95

Pressure vs. Input Current

Pressure

LE

C08-2
(See BC Section for more details)

20

40

60

80

Input Current (%)

Technical
Data

PV15

Parker Hannifin Corporation


Hydraulic Cartridge Systems

100

Proportional Relief Valve


Series AP02B2YR 07A, 14A, 21A, 35A

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)
Check
Valves

Dimensions

66.5
(2.62)

25.4 Dia
(1.00)
Finger Tight
Torque

34.2
(1.35)

22.0
(0.86)

36.0
(1.43)
See Super Coil
5/8" I.D.
Information For
Terminal Connectors

FC

3/4 Hex.
15 Nm (11 lb. ft.)
Torque

(2)

Load/Motor
Controls

LM

Flow
Controls

93.3
(3.67)

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

Shuttle
Valves

SH

PC
Pressure
Controls

3/4-16 UNF

(1)

Logic
Elements

LE

Ordering Information

MV
Coil
Voltage

Coil
Termination

Body
Material

Port
Size

Code Coil Type

Code Coil Termination

Code Body Material

Omit Without Coil

Omit Without Coil

Omit Steel

SP

Super Coil - 28 Watts

D
A

DIN Plug Face


Amp Jr. Timer*

Aluminum

21AL 210 Bar (3000 PSI)

Code Coil Voltage

Dual Lead Wire*

Code Port Size

35AL 350 Bar (5000 PSI)

Omit Without Coil


D012 12 VDC

LS
H

Sealed Lead Wire*


Molded Deutsch*

Omit Cartridge Only


4P 1/4 NPTF (B08-2-*4P)
6P 3/8 NPTF (B08-2-*6P)

Fluorocarbon /
(SK30006V-1)

Ethylene Propylene

D024 24 VDC

See Super Coil 5/8 I.D.


*DC Only

4T
6T

SAE-4
SAE-6

(B08-2-*4T)
(B08-2-*6T)

6B

3/8 BSPG (B08-2-*6B)

* Add A for aluminum, omit for steel.

PV

CE

BC
Bodies &
Cavities

Code Seals / Kit. No.


N Nitrile / Buna-N (Std.)
(SK30006N-1)

Body Part No.

TD
Technical
Data

Custom pressure setting available.


Consult factory.

SV
Solenoid
Valves

07AL 70 Bar (1000 PSI)


14AL 140 Bar (2000 PSI)

Coil
Type

Proportional
Valves

Code Style (Maximum


Relief Pressure)

Seals

Coils &
Electronics

Style

Manual
Valves

AP02B2YR
08 Size
Proportional
Relief Valve

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

PV16

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Relief Valve


Series AP04G2YR 10C, 21C, 35C

Catalog HY15-3502/US

Technical Information
CV

General Description

Shuttle
Valves

Check
Valves

SH

Proportional Relief Valve. Decreasing Pressure With


Increasing Current. For additional information see
Technical Tips on pages PV1-PV6.

Features

LM
Load/Motor
Controls

FC
Flow
Controls

Pilot operated spool-type design

One piece cartridge housing ensures internal


concentricity

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Precise setting of factory preset pressure in de-energized


mode

(1)

(2)

(2)

PC

Logic
Elements

DC
Directional
Controls

Rated Flow
(At 300 PSI P)
When Coil is Fully
Energized

95 LPM (25 GPM)

Factory Set Relief


Pressure When
Coil De-Energized
Measured at
45 LPM (12 GPM)

10C
21C
35C

Performance Curves
PWM Current Regulator Recommended
Relief Performance
PSI

103 Bar (1500 PSI)


210 Bar (3000 PSI)
350 Bar (5000 PSI)

Hydraulic Oil 150 SSU @ 100F (32 cSt)

Bar

5000 345
-35

4000 274

Relief Pressure

Pressure
Controls

LE

(1)

Specifications

3000 205

Manual
Valves

SV
Solenoid
Valves

PV

Hysteresis @
250 Hz PWM

< 7%
of Maximum Pressure Setting

Proportional
Valves

Response Time At
75% of Nominal
Voltage Change
(Measured To 90%
of Press. Change)

To Unload 45ms
To Load
25ms

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

CE

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Coils &
Electronics

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

-21

-10

1000
300

68
21
0
LPM
0
GPM

Bodies &
Cavities

Cavity

C10-2
(See BC Section for more details)

19

38

57

76

95

10

15

20

25

Flow (Q)

Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
5000 345

-35

4000 274
3000 205

-21

2000 137
-10

1000

68
0
0

.14 kg (.30 lbs.)

Coil Fully Energized

Pressure vs. Input Current

BC

Approx. Weight

Coil De-Energized

2000 137

Pressure

MV

19

38

57

Input Current (%)

TD
Technical
Data

PV17

Parker Hannifin Corporation


Hydraulic Cartridge Systems

75

Proportional Relief Valve


Series AP04G2YR 10C, 21C, 35C

Catalog HY15-3502/US

Technical Information

CV

Dimensions

Check
Valves

Millimeters (Inches)

62.7
(2.47)

SH

See Super Coil


1/2" I.D.
Information For
Terminal Connectors

FC

1 Hex.
34 Nm (25 lb. ft.)
Torque
31.8
(1.25)

PC

7/8-14 UNF

Pressure
Controls

(2)

(1)

LE
Logic
Elements

15.8
(0.62)

LM
Load/Motor
Controls

10.0
(0.40)

33.8
(1.33)

Flow
Controls

89.7
(3.53)

XXVDC XXW
CCX XXX H

PAT.XXXXXXX
MADEINU.S.A.

39.6
(1.56)

Shuttle
Valves

19.8
(0.78)

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

Ordering Information

MV

Code Seals / Kit. No.


N

Nitrile / Buna-N (Std.)


(SK30503N-1)

Fluorocarbon /
(SK30503V-1)

Coil
Termination

Body
Material

Port
Size

Code Coil Termination

Code Body Material

Omit Without Coil

Omit Without Coil

Omit Steel

SP

Super Coil - 19 Watts

D
A

DIN Plug Face


Amp Jr. Timer*

Code Coil Voltage

Dual Lead Wire*

Code Port Size

Omit Without Coil


D012 12 VDC

LS
H

Sealed Lead Wire*


Molded Deutsch*

Omit
4P
6P
8P
6T
8T
T8T

Cartridge Only
1/4 NPTF (B10-2-*4P)
3/8 NPTF (B10-2-*6P)
1/2 NPTF (B10-2-*8P)
SAE-6
(B10-2-*6T)
SAE-8
(B10-2-*8T)
SAE-8
(B10-2-T8T)

6B

3/8 BSPG (B10-2-*6B)

D024 24 VDC

See Super Coil 1/2 I.D.


*DC Only

SV
Solenoid
Valves

Code Coil Type

Aluminum
Body Part No.

* Add A for aluminum, omit for steel.


Steel body only.

PV
Proportional
Valves

35C 350 Bar (5000 PSI)


Custom pressure setting available.
Consult factory.

Coil
Voltage

CE
Coils &
Electronics

10C 104 Bar (1500 PSI)


21C 210 Bar (3000 PSI)

Coil
Type

BC
Bodies &
Cavities

Code Style (Maximum


Relief Pressure)

Seals

TD
Technical
Data

Style

Manual
Valves

AP04G2YR
10 Size
Proportional
Relief Valve

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

PV18

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Pressure Reducing Valve


Series GP0130

Catalog HY15-3502/US

Technical Information
CV

General Description

Shuttle
Valves

Check
Valves

SH

3 Way, 2 Position, Proportional Pressure Reducing


Valve. Bottom Cylinder Port. For additional information
see Technical Tips on pages PV1-PV6.

Features

LM
Load/Motor
Controls

FC
Flow
Controls

Designed for pilot control of directional valves

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Low Hysteresis
One piece cartridge housing ensures internal
concentricity

(1)

(3)

PC

Manual
Valves

SV
Solenoid
Valves

Rated Flow
(At 70 PSI P)

1.9 LPM (0.5 GPM)

Max. Regulated
Pressure @ 75%
Current

Standard
17 Bar (250 PSI)
High Pressure
22 Bar (320 PSI)

Max. Input Press.


At Port 1

210 Bar (3000 PSI)

Max. Tank Press.

30 Bar (440 PSI)

Max. Drainage
Flow In Regulating
Zone

5 cc/min. When De-Energized


200 cc/min. In Regulating Zone
At 68 Bar (1000 PSI) Input Pressure

Hysteresis @
200 Hz PWM

2%

Dead End
Response Time

t on = 30 ms
t off = 10 ms
At Step Signal 0 To 75%
of Nominal Voltage

2 to 1
Energized

200 13.6
1 to 3
De-Eenergized

100

6.8

0
LPM
0
GPM

.95

1.9

2.9

3.8

.25

.50

.75

1.0

Flow (Q)

Pressure @ Port 1 vs. Input Current


PSI Bar
400 27.4

Hydraulic Oil 150 SSU @ 100F (32 cSt)


With 'SS' Coil @ 120 Hz PWM

PV

CE

Operating Temp.
Range/Seals

300 20.5
200 13.6
100

6.8
0

All parts steel. All operating


parts hardened steel.
-40C to +93.3C (Nitrile)
(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

TD

Approx. Weight

.08 kg (.17 lbs.)

Technical
Data

Coils &
Electronics

Proportional
Valves

Cartridge Material

Cavity

54-1
(See BC Section for more details)

BC

Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
300 20.5

Pressure Drop

Directional
Controls

MV

Reducing
Pressure
(1)

Pressure Drop vs. Flow

Specifications

Pressure

Logic
Elements

DC

(2)

Performance Curves
PWM Current Regulator Recommended

12V
24V

.2

.4

.6

.8

1.0

1.2

.1

.2

.3

.4

.5

.6

AMP

Pressure @ Port 1 vs. Input Current


PSI Bar
500 34.0

Hydraulic Oil 150 SSU @ 100F (32 cSt)


With 'SP' Coil @ 120 Hz PWM

400 27.4

Bodies &
Cavities

Pressure

Pressure
Controls

LE

Tank
(3)
Inlet
(2)

300 20.5
200 13.6
100

6.8
0
12V
24V

PV19

.2

.4

.6

.8

1.0

1.2

1.4

1.6

.1

.2

.3

.4

.5

.6

.7

.8

AMP

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Pressure Reducing Valve


Series GP0130

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)
Check
Valves

Dimensions

62.7
(2.47)
Manual
Override
Finger
Tight
Torque

(3)

27.8
(1.09)

Flow
Controls

5.6
(0.22)

FC

See Super Coil


1/2" I.D.
Information For
Terminal Connectors
13/16 Hex.
27 Nm (20 lb. ft.)
Torque
M18X1.5

PC
Pressure
Controls

85.5
(3.36)

XXVDC XXW
CCX XXX H

PAT.XXXXXXX
MADEINU.S.A.

39.6
(1.56)

LM

33.8
(1.33)

Load/Motor
Controls

12.4
(0.49)

SH
19.8
(0.78)

Shuttle
Valves

9.70
(0.38)

(2)

LE
Logic
Elements

11.9
(0.47)

(1)

NOTE: Requires 54-1 Cavity

Ordering Information

Style

Override
Option

Code Style
30

Standard (SS Coil)

30

High Pressure
(SP Coil)

Coil
Type

Coil
Voltage

Coil
Termination

Code Coil Type

Code Coil Termination

Omit Not Required

Omit Without Coil

Omit Without Coil

60 Mesh Screen on
Inlet Port

Code Seals / Kit No.


N Nitrile / Buna-N (Std.)
(SK30122N-1)

Manual Override

Seals

Code Filter Screen


F

Code Override Option


Omit If No M.O.

Filter
Screen

Manual
Valves

08 Size
Proportional
Valve

MV

Fluorocarbon /
(SK30122V-1)

Super Coil - 14 Watts


Super Coil - 19 Watts

Code Coil Voltage


Omit Without Coil
D012 12 VDC
D024 24 VDC

D
A

DIN Plug Face


Amp Jr. Timer*

Dual Lead Wire*

LS
H

Sealed Lead Wire*


Molded Deutsch*

See Super Coil 1/2 I.D.


*DC Only

PV

CE
Coils &
Electronics

SS
SP

SV
Solenoid
Valves

30

Proportional
Valves

GP01

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

BC

Body Material

Bodies &
Cavities

Order Bodies Separately

Code Body Material

TD

Line Body
Code Porting
591 1/4 SAE

Porting

Aluminum

Steel

Technical
Data

LB10

PV20

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Pressure Reducing Valve


Series GTP0234

Catalog HY15-3502/US

Technical Information
CV

General Description

Shuttle
Valves

Check
Valves

SH

3 Way, 2 Position, Proportional Pressure Reducing


Valve. Side Cylinder Port. For additional information
see Technical Tips on pages PV1-PV6.

Features

LM
Load/Motor
Controls

Minimal Hysteresis

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

FC
Flow
Controls

One piece cartridge housing ensures internal


concentricity

Inlet
(3)

(2)

Nonmagnetic spool and housing assembly

Reducing
Pressure
(2)

(1)

(3)

PC

Directional
Controls

MV
Manual
Valves

SV
Solenoid
Valves

Rated Flow
(At 70 PSI P)

19 LPM (5 GPM)

Max. Regulated
Pressure @ 75%
Current
(Using SP Coil)

02
03
05
06
09
18

Max. Input Press.


At Port 3

210 Bar (3000 PSI)

Max. Drainage
Flow In Regulating
Zone

100 cc/min. When De-Energized


750 cc/min. In Regulating Zone
At 21 Bar (300 PSI) Input Pressure

Hysteresis @
100 Hz PWM

3.5%

Dead End
Response Time

10 ms At Step Signal
0 To 75% of Nominal Voltage

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

PV
Proportional
Valves

CE

12/17 Bar (180/240 PSI)


19/26 Bar (270/375 PSI)
31/40 Bar (450/580 PSI)
41/51 Bar (600/740 PSI)
65/79 Bar (940/1140 PSI)
114/145 Bar (1650/2100 PSI)

Performance Curves
PWM Current Regulator Recommended
Pressure Drop vs. Flow
Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
200 14.0

Pressure Drop

Logic
Elements

DC

Specifications

150 10.5
3 to 2

100

7.0

50

3.5

2 to 1

0
LPM
0
GPM

3.8

7.6

11.4

15.2

18.9

Flow (Q)

Pressure @ Port 2 vs. Input Current


Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
600 41.4

With 'SP' Coil @ 100 Hz PWM

Coils &
Electronics

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

BC
Bodies &
Cavities

Approx. Weight

.08 kg (.17 lbs.)

Cavity

C08-3
(See BC Section for more details)

500 34.5
GTP0234 06

Control Pressure

Pressure
Controls

LE

Tank
(1)

400 27.4
300 20.7
GTP0234 03

200 13.8
GTP0234 02

6.9

100
0

24V
12V

TD

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.2

0.4

0.6

0.8

1.0

1.2

1.4

Current Amps

Technical
Data

PV21

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Pressure Reducing Valve


Series GTP0234

Catalog HY15-3502/US

Technical Information

CV

13.21
(0.52)

Check
Valves

Millimeters (Inches)
62.7
(2.47)

19.8
(0.78)

XXVDC XXW
CCX XXX H

See Super Coil


1/2" I.D.
Information For
Terminal Connectors

93.75
(3.69)

FC

7/8 Hex.
27 Nm (20 lb. ft.)
Torque

PC
Pressure
Controls

3/4-16 UNF
(3)
(2)

Logic
Elements

LE
(1)

14.2
(0.56)

Ordering Information

Filter
Screen

Seals

Code Filter Screen


1

60 Mesh Screen on
Inlet Port

02
03

12/17 Bar (180/240 PSI)


19/26 Bar (270/375 PSI)

05

31/40 Bar (450/580 PSI)

06
09

41/51 Bar (600/740 PSI)


65/79 Bar (940/1140 PSI)

Nitrile / Buna-N (Std.)


(SK30081N-1)

18

114/145 Bar (1650/2100 PSI)

Fluorocarbon /
(SK30081V-1)

Code Override Option


0

Not Required

Detented M.O.

Coil
Type

Coil
Voltage

Coil
Termination

Omit Without Coil


SS Super Coil - 14 Watts
SP

Super Coil - 19 Watts

Port
Size

Code Coil Voltage

Code Body Material

Omit Without Coil

Omit Steel

D012 12 VDC
D024 24 VDC

Code Seals / Kit No.

Code Coil Type

Body
Material

Aluminum

Code Port Size


Code Coil Termination
Omit Without Coil
D

DIN Plug Face

A
L

Amp Jr. Timer*


Dual Lead Wire*

LS

Sealed Lead Wire*

Molded Deutsch*

Body Part No.

Omit Cartridge Only


4P 1/4 NPTF (B08-3-*4P)
4T
6T
6B

SV

SAE-4
(B08-3-*4T)
SAE-6
(B08-3-*6T)
3/8 BSPG (B08-3-*6B)

* Add A for aluminum, omit for steel.

See Super Coil 1/2 I.D.


*DC Only

PV

CE

BC
Bodies &
Cavities

Code Style (Maximum Regulated


Pressure Range - SP COIL)

Override
Option

TD
Technical
Data

Style

Manual
Valves

MV

Solenoid
Valves

GTP0234
08 Size
Proportional
Valve

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

Proportional
Valves

40.21
(1.58)

LM

Flow
Controls

PAT.XXXXXXX
MADEINU.S.A.

5.59
(0.22)

33.8
(1.33)

Load/Motor
Controls

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque
39.6
(1.56)

SH
Shuttle
Valves

Manual Override
(Infinite Control)

Coils &
Electronics

Dimensions

PV22

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Pressure Reducing Valve


Series GTP0434

CV

General Description

Shuttle
Valves

Check
Valves

SH

3 Way, 2 Position, Proportional Pressure Reducing


Valve. Side Cylinder Port. For additional information
see Technical Tips on pages PV1-PV6.

Features

LM
Load/Motor
Controls

Minimal Hysteresis

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

FC
Flow
Controls

One piece cartridge housing ensures internal


concentricity
Inlet
(3)

(2)

Nonmagnetic spool and housing assembly


(1)

Reducing
Pressure
(2)

(3)

PC
Pressure
Controls

Tank
(1)

30 LPM (8 GPM)

Max. Regulated
Pressure @ 75%
Current
(Using SP Coil)

02
03
05
09

Max. Input Press.


At Port 3

210 Bar (3000 PSI)

MV
Manual
Valves

Logic
Elements

Rated Flow
(At 70 PSI P)

Max. Drainage
Flow In Regulating
Zone

25 cc/min. When De-Energized


800 cc/min. In Regulating Zone
At 21 Bar (300 PSI) Input Pressure

Hysteresis @
200 Hz PWM

3.5%

DC
Directional
Controls

SV

14/17 Bar (200/240 PSI)


21/27 Bar (300/390 PSI)
29/38 Bar (420/550 PSI)
56/74 Bar (810/1080 PSI)

Solenoid
Valves

Dead End
Response Time

40 ms At Step Signal
0 To 75% of Nominal Voltage

PV

Cartridge Material

Proportional
Valves

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

CE
Coils &
Electronics

Fluid
Compatibility/
Viscosity

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)
Mineral-based or synthetic with
lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

BC

Filtration

Bodies &
Cavities

ISO Code 16/13,


SAE Class 4 or better

Approx. Weight

.13 kg (.28 lbs.)

Cavity

3X
(See BC Section for more details)

TD

Performance Curves
PWM Current Regulator Recommended
Pressure Drop vs. Flow
Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
200 14.0

Pressure Drop

Specifications

150 10.5

100

7.0
2 to 1
3 to 2

50

3.5

0
LPM
0
GPM

7.6

15.2

22.7

30.4

37.8

10

Flow (Q)

Pressure @ Port 2 vs. Input Current


Hydraulic Oil 150 SSU @ 100F (32 cSt)

PSI Bar
1000 69.0

With 'SP' Coil @ 100 Hz PWM

GTP04 3409

800 55.2

Control Pressure

LE

600 41.4
GTP04 3405

400 27.6
GTP04 3403

200 13.8
GTP04 3402

0
24V

Technical
Data

12V

PV23

0.13

0.25

0.38

0.50

0.63

0.75

0.88

0.25

0.50

0.75

1.00

1.25

1.50

1.75

Current Amps

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Pressure Reducing Valve


Series GTP0434

Catalog HY15-3502/US

Technical Information

CV

Dimensions

66.5
(2.62)

Manual Override
(Infinite Control)

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

SH

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

112.8
(4.44)

LM
Load/Motor
Controls

36.0
(1.43)

FC
Flow
Controls

5.54
(0.22)

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

22.0
(0.86)

Shuttle
Valves

13.21
(0.52)

Check
Valves

Millimeters (Inches)

1 Hex.
30 Nm (22 lb. ft.)
Torque

PC
Pressure
Controls

7/8-14 UNF
(3)
48.87
(1.92)

LE
Logic
Elements

(2)

(1)

17.4
(0.69)

NOTE: Requires 3X Cavity

Ordering Information

MV

14/17 Bar (200/240 PSI)


21/27 Bar (300/390 PSI)

05

29/38 Bar (420/550 PSI)

09

56/74 Bar (810/1080 PSI)

Seals

Code Override Option

Code Style (Maximum Regulated


Pressure Range - SP Coil)
02
03

Filter
Screen

Not Required

Detented M.O.

Coil
Type

Code Filter Screen

Contact factory for other regulated


pressure to 124 Bar (1800 PSI)

60 Mesh Screen on
Inlet Port

Coil
Termination

Code Seals / Kit No.

V
1

Coil
Voltage

Nitrile / Buna-N (Std.)


(SK30081N-1)
Fluorocarbon /
(SK30081V-1)

Code Coil Type


Omit Without Coil
SS
SP

Super Coil - 18 Watts


Super Coil - 28 Watts

Code Coil Voltage


Omit Without Coil
D012 12 VDC
D024 24 VDC

PV
Code Coil Termination
Omit Without Coil
D

DIN Plug Face

A
L

Amp Jr. Timer*


Dual Lead Wire*

LS

Sealed Lead Wire*

Molded Deutsch*

See Super Coil 5/8 I.D.


*DC Only

Code Body Material

TD

553 1/2 SAE

Aluminum

554 3/8 BSP

Steel

Technical
Data

Code Porting

Porting

BC

Body Material

LB10
Line Body

CE

Bodies &
Cavities

Order Bodies Separately

SV
Solenoid
Valves

Override
Option

Proportional
Valves

Style

Manual
Valves

Coils &
Electronics

GTP0434
10 Size
Proportional
Valve

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

PV24

Parker Hannifin Corporation


Hydraulic Cartridge Systems

N.C. Proportional Flow Control Valve


Series DF122C

Catalog HY15-3502/US

Technical Information
CV

General Description

Shuttle
Valves

Check
Valves

SH

Normally Closed Proportional Flow Control Valve.


For additional information see Technical Tips
on pages PV1-PV6.

Features

LM
Load/Motor
Controls

FC

On-off type solenoids


Low hysteresis
PWM signal preferred
Manual override standard

(2)

All external parts zinc plated

Flow
Controls

In
(2)

(1)

PC
Pressure
Controls

Out
(1)

Logic
Elements

Rated Flow
Valve Fully Open

53 LPM (14 GPM)

DC

Maximum Inlet
Pressure

210 Bar (3000 PSI)

Hysteresis
@ 200 Hz PWM

4%

Cracking
(Dead band)

20% - 30% of Input Signal

Frequency

100 - 400 Hz (200 Hz Preferred)

MV

Performance Curves

Pressure Drop ( P)

Specifications

Directional
Controls

LE

PSI
300

Bar
20.7

200

13.8

100

6.9

Pressure Drop vs. Flow @ 100% Control Current


Hydraulic Oil 150 SSU @ 100F (32 cSt)

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Proportional
Valves

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)
ISO Code 16/13,
SAE Class 4 or better

Coils &
Electronics

Fluid
Compatibility/
Viscosity
Filtration
Approx. Weight

.32 kg (0.7 lbs.)

BC

Cavity

C12-2
(See BC Section for more details)

Bodies &
Cavities

Form Tool

Rougher
Finisher

None
NFT12-2F

GPM LPM
30 114

Flow (Q)

Solenoid
Valves

All parts steel. All operating


parts hardened steel.

19
5

38
10

57
15

76
20

Flow (Q)

24VDC
1.23A

Cartridge Material

PV

CE

12 VDC
2.45A

20

76

10

38

Flow vs. Inlet Pressure @ 100% Control Current


Hydraulic Oil 150 SSU @ 100F (32 cSt)

0
Bar
0
PSI

69
1000

207
3000

138
2000

Inlet Pressure
GPM LPM
15
57

Flow (Q)

Manual
Valves

SV

Maximum Control
Current

LPM
0
GPM

10

38

19

Flow vs. Input Signal (Current)


Hydraulic Oil 150 SSU @ 100F (32 cSt)

TD
Technical
Data

0
0

25

50

75

Percent of Maximum Control Current

PV25

Parker Hannifin Corporation


Hydraulic Cartridge Systems

100

N.C. Proportional Flow Control Valve


Series DF122C

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)

56.0
(2.20)

Check
Valves

Dimensions

48.0
(1.90)

SH
Shuttle
Valves

Finger
Tight
Torque
See DS Coil 1" I.D.
Information For
Terminal Connectors

Load/Motor
Controls

60.0
(2.35)

17
(.66)

FC
Flow
Controls

161.0
(6.33)

LM

1-1/4" Hex.
29 Nm (21 lb. ft.)
Torque

PC
1-1/16 - 12 UNF-2A
Thread

22.2
(.87)

LE

(1)

THIRD-ANGLE
PROJECTION

Logic
Elements

41.3
(1.63)

Pressure
Controls

(2)

Directional
Controls

DC

Ordering Information

DF122C14
Seals

Coil
Voltage

Coil
Wattage

Coil
Termination

Body
Material

Port
Size

Manual
Valves

Override
Options

SV

Code Coil Voltage

Code Coil Termination

Code Body Material

Omit Push Type with


Extended Rod

Omit Cartridge without Coil


D012 12 VDC

Omit Cartridge without Coil


D DIN

Omit Steel
A Aluminum

D024 24 VDC

Dual Wire

See DS Coil 1 I.D.

Omit Cartridge
without Coil
H High Watt

Code Port Size Body Part No.


12P 3/4 NTPF (B12-2-*12P)
8T SAE - 8
12T SAE - 12

(B12-2-*8T)
(B12-2-*12T)

* Add A for aluminum, omit for steel.

PV

CE
Coils &
Electronics

Fluorocarbon / (SK12-2V)

Dual Spade

BC
Bodies &
Cavities

Code Coil Wattage

P
W

TD
Technical
Data

Code Seals / Kit. No.


Omit Nitrile / (SK12-2)

Solenoid
Valves

Code Override Options

Proportional
Valves

12 Size Normally
Closed Proportional
Flow Control Valve

MV

PV26

Parker Hannifin Corporation


Hydraulic Cartridge Systems

N.C. Proportional Needle Valve


Series DF161C

Catalog HY15-3502/US

Technical Information
CV

General Description
Check
Valves

SH
Shuttle
Valves

LM
Load/Motor
Controls

FC

Normally Closed Proportional Needle Valve. This valve


is designed specifically for bleed off or unloading
circuits. Back pressure will affect performance. For
additional information see Technical Tips on pages
PV1-PV6.

Features

Flow
Controls

On-off type solenoids


Low hysteresis
(2)

PWM signal preferred


All external parts zinc plated

Inlet
(2)

(1)

PC
Pressure
Controls

Outlet
(1)

Specifications

Logic
Elements

Rated Flow
Valve Fully Open

High Watt Coil


150 LPM (40 GPM)

DC

210 Bar (3000 PSI)

Directional
Controls

Maximum Inlet
Pressure
Leakage at
150 SSU (32 cSt)

125 cc/min. (7.6 in3/min.)

MV

Hysteresis
@ 200 Hz PWM

4%

Cracking
(Dead band)

20% - 30% of Input Signal

Frequency

100 - 400 Hz (200 Hz Preferred)

Maximum Control
Current

12 VDC
High Watt 2.45A

Cartridge Material

All parts steel. All operating


parts hardened steel.

Proportional
Valves

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

CE

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

SV
Solenoid
Valves

PV

Coils &
Electronics

BC

Performance Curves
Pressure Drop vs. Flow @ 100% Current

Pressure Drop ( P)

PSI Bar
400 27.6

.34 kg (0.75 lbs.)

Bodies &
Cavities

Cavity

C16-2
(See BC Section for more details)

TD

Form Tool

Rougher
Finisher

Technical
Data

Approx. Weight

Hydraulic Oil 150 SSU @ 100F (32 cSt)

300 20.7

200 13.8
High Watt

100

24VDC
1.23A

6.9

0
LPM
0
GPM

38

75

113

150

10

20

30

40

Flow (Q)

Flow vs. Input Signal (Current)


GPM LPM
40 150

Hydraulic Oil 150 SSU @ 100F (32 cSt)

30 113

Flow (Q)

Manual
Valves

LE

High Watt @
207 Bar
(3000 PSI)

20

75

10

38
High Watt @
34.5 Bar
(500 PSI)

None
NFT16-2F

0
A

.5

1.0

1.5

2.0

2.5

Current in Amps

PV27

Parker Hannifin Corporation


Hydraulic Cartridge Systems

3.0

N.C. Proportional Needle Valve


Series DF161C

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)
Check
Valves

Dimensions

56.0
(2.20)

48.1
(1.90)

SH
Shuttle
Valves

4.1 Nm
(3 lb. ft.)
Torque
See DS Coil 1" I.D.
Information For
Terminal Connectors

Load/Motor
Controls

LM
59.8
(2.35)

FC

136.8
(5.38)

Flow
Controls

1-1/2" Hex.
54 Nm (40 lb. ft.)
Torque

1-5/16 - 12 UN-2A
Thread

Pressure
Controls

PC
44.4
(1.75)

Inlet
(2)
THIRD-ANGLE
PROJECTION

LE
Logic
Elements

Outlet
(1)

28.5
(1.12)

Directional
Controls

DC

Ordering Information

DF161C40
Seals

Coil
Voltage

Coil
Termination

Body
Material

Port
Size

Manual
Valves

16 Size Normally
Closed Proportional
Flow Control Valve

MV

Code Body Material

Omit Nitrile / (SK16-2)


V Fluorocarbon / (SK16-2V)

Omit Cartridge without Coil


D012 12 VDC

Omit Cartridge without Coil


D DIN

Omit Steel
A Aluminum

Dual Spade

Dual Wire

See DS Coil 1 I.D

Code Port Size Body Part No.


12P 3/4 NTPF (B16-2-*12P)
16P 1 NTPF
(B16-2-*16P)
8T SAE - 8
12T SAE - 12
16T SAE - 16

(B16-2-*8T)
(B16-2-*12T)
(B16-2-*16T)

12B 3/4 BSPG (B16-2-12B)


16B 1 BSPG (B16-2-*16B)

CE

BC
Bodies &
Cavities

* Add A for aluminum, omit for steel.


Steel body only.

PV

TD
Technical
Data

D024 24 VDC

Proportional
Valves

Code Coil Termination

Coils &
Electronics

Code Coil Voltage

Solenoid
Valves

SV
Code Seals / Kit. No.

PV28

Parker Hannifin Corporation


Hydraulic Cartridge Systems

N.C. Proportional Needle Valve


Series DF201C

Catalog HY15-3502/US

Technical Information
CV

General Description
Check
Valves

SH
Shuttle
Valves

LM
Load/Motor
Controls

FC

Normally Closed Proportional Needle Valve. This valve


is designed specifically for bleed off or unloading
circuits. Back pressure will affect performance. For
additional information see Technical Tips on pages
PV1-PV6.

Features

On-off type solenoids


Low hysteresis
PWM signal preferred
(1)

All external parts zinc plated

Flow
Controls

Inlet
(2)

(2)
Outlet
(1)

PC
Pressure
Controls
Logic
Elements

Performance Curves

Rated Flow
Valve Fully Open

Low Watt 180 LPM (48 GPM)


High Watt 227 LPM (60 GPM)

DC

Maximum Inlet
Pressure

210 Bar (3000 PSI)


125 cc/min. (7.6 in3/min.)

MV

Hysteresis
@ 200 Hz PWM

4%

Cracking
(Dead band)

20% - 30% of Input Signal

Frequency

100 - 400 Hz (200 Hz Preferred)

Maximum Control
Current

12 VDC
Low Watt 1.75A
High Watt 2.45A

SV
Solenoid
Valves

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

PV
Proportional
Valves

CE
Coils &
Electronics

BC
Bodies &
Cavities

TD

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Approx. Weight
Cavity

Technical
Data

Form Tool

Low Watt

300 21.7

200 14.5
High Watt

100

24VDC
.91A
1.23A

Cartridge Material

7.2

0
LPM
0
GPM

38

76

113

151

189

227

10

20

30

40

50

60

Flow (Q)

Flow vs. Input Signal (Current)


GPM LPM
60 227

Hydraulic Oil 150 SSU @ 100F (32 cSt)

High Watt @
207 Bar
(3000 PSI)

189

50

Low Watt @
207 Bar (3000 PSI)

40

150

30

113

.34 kg (0.75 lbs.)

20

75

C20-2
(See BC Section for more details)

10

Rougher
Finisher

Hydraulic Oil 150 SSU @ 100F (32 cSt)

400 29.0

Flow (Q)

Manual
Valves

Leakage at
150 SSU (32 cSt)

Pressure Drop vs. Flow @ 100% Current


PSI Bar
500 36.2

Pressure Drop ( P)

Specifications

Directional
Controls

LE

Low Watt @
34.5 Bar (500 PSI)

38
High Watt @
34.5 Bar (500 PSI)

None
NFT20-2F

.5

1.0

1.5

2.0

2.5

Current in Amps

PV29

Parker Hannifin Corporation


Hydraulic Cartridge Systems

3.0

N.C. Proportional Needle Valve


Series DF201C

Catalog HY15-3502/US

Technical Information

CV

Dimensions

Check
Valves

Millimeters (Inches)

56.0
(2.20)

48.3
(1.90)

SH
Shuttle
Valves

4.1 Nm
(3 lb. ft.)
Torque
See DS Coil 1" I.D.
Information For
Terminal Connectors

Load/Motor
Controls

LM
60.5
(2.38)

1-7/8" Hex.
113 Nm (83 lb. ft.)
Torque

FC
Flow
Controls

142.2
(5.60)

1 5/8-12 UN-2A
Thread

Pressure
Controls

PC
55.1
(2.17)

Inlet
(2)

THIRD-ANGLE
PROJECTION

Logic
Elements

LE
Outlet
(1)

36.8
(1.45)

Directional
Controls

DC

Ordering Information

DF201C60
Seals

Coil
Voltage

Coil
Wattage

Coil
Termination

Body
Material

Port
Size

Manual
Valves

20 Size Normally
Closed Proportional
Flow Control Valve

MV

Code Coil Termination

Code Body Material

Omit Nitrile / (SK20-2)


V Fluorocarbon / (SK20-2V)

Omit Cartridge without Coil


D012 12 VDC

Omit Cartridge without Coil


D DIN

Omit Steel
A Aluminum

D024 24 VDC
Code Coil Wattage

Dual Spade

Dual Wire

See DS Coil 1 I.D.

Omit Cartridge
without Coil
L Low Watt

Body Part No.


(B20-2-*20T)

20B 1-1/4 BSPG (B20-2-*20B)


* Add A for aluminum, omit for steel.

PV

Coils &
Electronics

CE

High Watt

Bodies &
Cavities

BC

TD
Technical
Data

Code Port Size


20T SAE - 20

Proportional
Valves

Code Coil Voltage

Solenoid
Valves

SV
Code Seals / Kit. No.

PV30

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Flow Regulator Valve


Series HP02C 21

CV

General Description

Shuttle
Valves

Features

LM
Load/Motor
Controls

FC
Flow
Controls

PC
Pressure
Controls

LE

Analog Proportional Partially Pressure Compensated


Flow Regulator regulates flow proportionally to the input
solenoid current.
A low cost valve designed to be used in applications
where fine pressure compensation is not required.
One piece cartridge housing ensures internal
concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
affecting performance.
Nonmagnetic spool and housing assembly
Factory-adjusted low variation option (Model L) is
available for applications where low variation of flow from
valve to valve is essential at a given current or when an
external pressure compensator is used.

Logic
Elements

Specifications
Rated Flow @
210 Bar (3000 PSI)

DC

<10%

SV

Cracking Pressure

25% of Input Current

Variation of Flow
@ 35% of Rated
Current & Constant
P Maintained By
Pressure
Compensator

Standard Model
Up To 20% Of Rated Flow
Model L
7% Of Rated Flow

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

PV
Proportional
Valves

CE

(1)

(2)

Performance Curves
PWM Current Regulator Recommended
Flow vs. Input Current
GPM LPM
6 22.8

Hydraulic Oil 150 SSU @ 100F (32 cSt)

2 to 1 ('SP' Coil)

15.2
1 to 2 ('SP' Coil)

7.6
2 to 1 ('SS' Coil)
1 to 2 ('SS' Coil)

0
0

20

40

60

80

100

Input Current (%)

Flow Regulation (Measured at 75% of Rated Current)


GPM LPM
8 30.4

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

TD

Approx. Weight

.08 kg (.17 lbs.)

Technical
Data

Coils &
Electronics

Fluid
Compatibility/
Viscosity

Cavity

2X
(See BC Section for more details)

BC

(1)

Flow

Hysteresis @
100 Hz PWM

Solenoid
Valves

Port 1

MV

Preferable Input
Port For Best
Hysteresis

Manual
Valves

Directional
Controls

Standard (SS Coil)


2 to 1 13.3 LPM (3.5 GPM)
1 to 2 9.5 LPM (2.5 GPM)
High Flow (SP Coil)
2 to 1 22.8 LPM (6.0 GPM)
1 to 2 15.0 LPM (4.0 GPM)

(2)

Flow

Check
Valves

SH

2 Way, Normally Closed, Proportional Flow Regulator


Valve. Partially Pressure Compensated. For additional
information see Technical Tips on pages PV1-PV6.

22.8

15.2

7.6

Hydraulic Oil 150 SSU @ 100F (32 cSt)

2 to 1 ('SP' Coil)

1 to 2 ('SP' Coil)
2 to 1 ('SS' Coil)
1 to 2 ('SS' Coil)

Bodies &
Cavities

0
Bar
PSI

PV31

35

70

105

140

175

210

500

1000

1500

2000

2500

3000

Pressure

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series HP02C 21

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)
Check
Valves

Dimensions

62.7
(2.47)

SH

Manual Override
(Infinite Control)
3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

33.8
(1.33)

FC

See Super Coil


1/2" I.D.
Information For
Terminal Connectors

82.04
(3.23)

7/8 Hex.
20 Nm (27 lb. ft.)
Torque

PC
Pressure
Controls

28.5
(1.12)

LM

Flow
Controls

5.59
(0.22)

XXVDC XXW
CCX XXX H

PAT.XXXXXXX
MADEINU.S.A.

39.6
(1.56)

Shuttle
Valves

19.8
(0.78)

Load/Motor
Controls

13.21
(0.52)

3/4-16 UNF
(2)

Logic
Elements

LE
(1)

15.9
(0.63)

NOTE: Requires 2X Cavity

Ordering Information

Override
Option

Standard (SS Coil)


13.3 LPM (3.5 GPM)

21

High Flow (SP Coil)


22.8 LPM (6.0 GPM)

Not Available

Code Seals / Kit No.


N
V

Code Override Option


0
5

Seals

Code Filter Screen

Code Style (Maximum


Regulated Flow)
21

Filter
Screen

Nitrile / Buna-N (Std.)


(SK30076N-1)
Fluorocarbon /
(SK30076V-1)

Not Required
Detented M.O.
(Infinite Control)

Flow
Variation

Coil
Type

Coil
Voltage

Coil
Termination

Code Flow Variation

Code Coil Voltage

Omit Standard Up to 20%


of Rated Flow
L Low Variation
(7% of Rated Flow)

D012 12 VDC
D024 24 VDC

Code Coil Type

Code Coil Termination


Omit Without Coil

Omit Without Coil


SS
SP

Super Coil - 14 Watts


Super Coil - 19 Watts

Omit Without Coil

DIN Plug Face

A
L

Amp Jr. Timer*


Dual Lead Wire*

LS

Sealed Lead Wire*

Molded Deutsch*

Bodies &
Cavities

BC

Code Body Material

TD

513 3/8 SAE

Aluminum

515 1/4 BSP

Steel

Technical
Data

Code Porting

Porting

CE

Body Material

LB10
Line Body

SV

PV

See Super Coil 1/2 I.D.


*DC Only

Order Bodies Separately

Manual
Valves

Style

Solenoid
Valves

08 Size
Proportional
Valve

MV

Proportional
Valves

21

Coils &
Electronics

HP02C

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

PV32

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series JP02C 20, 21

Catalog HY15-3502/US

Technical Information
CV

General Description
Check
Valves

SH
Shuttle
Valves

LM
Load/Motor
Controls

FC

2 Way, Normally Closed, Proportional Flow Regulator


Valve. Pressure Compensated. For additional information see Technical Tips on pages PV1-PV6.

Features

One piece cartridge housing ensures internal


concentricity

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Nonmagnetic spool and housing assembly

(3)

(2)

Flow
Controls

Factory-adjusted low variation option (Model L) is


available for applications where low variation of flow from
valve to valve is essential at a given current.

(2)

Port (1)
Is Not Used

(3)

PC

Logic
Elements

21
21

DC
Directional
Controls

Maximum Input
Pressure At Port 2

210 Bar (3000 PSI)

Minimum Pressure
Differential

20
21
21

MV
Manual
Valves

SV
Solenoid
Valves

PV
Proportional
Valves

CE
Coils &
Electronics

BC

7.5 LPM (2 GPM)


Low Flow (SS Coil)
15 LPM (4 GPM)
Standard (SS Coil)
23 LPM (6 GPM)
High Flow (SP Coil)

Hysteresis @
100 Hz PWM

<10% (Low Flow and Standard)


<3% (High Flow)

Cracking Pressure

25% of Input Signal

Variation of Flow
@ 35% of Rated
Current

Standard Model
Up To 20% Of Rated Flow
Model L
7% Of Rated Flow

Operating Temp.
Range/Seals

JP02C 21 ('SP' Coil)

15.2
JP02C 21
('SS' Coil)

570 cc (35 cu. in.)


@ 210 Bar (3000 PSI)

Bodies &
Cavities

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

TD

Approx. Weight

.08 kg (.17 lbs.)

Technical
Data

Cavity

C08-3
(See BC Section for more details)

7.6
JP02C 20
('SS' Coil)

0
20

40

60

80

100

Input Current (%)

Flow Regulation (Measured 75% of Rated Current)


GPM LPM

All parts steel. All operating


parts hardened steel.
-40C to +93.3C (Nitrile)
(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Hydraulic Oil 150 SSU @ 100F (32 cSt)

GPM LPM
6 22.8

6.9 Bar (150 PSI) Low Flow


13.8 Bar (200 PSI) Standard
20.7 Bar (300 PSI) High Flow

Maximum Internal
Leakage

Cartridge Material

Flow vs. Input Current

Flow

20

Flow

Rated Flow

Performance Curves
PWM Current Regulator Recommended

22.8

15.2

7.6

Hydraulic Oil 150 SSU @ 100F (32 cSt)


JP02C 21 ('SP' Coil)

JP02C 21 ('SS' Coil)

JP02C 20 ('SS' Coil)

0
Bar
PSI

35

70

105

140

175

210

500

1000

1500

2000

2500

3000

Pressure

Pressure Drop vs. Flow


PSI Bar

Hydraulic Oil 150 SSU @ 100F (32 cSt)

300 20.7

Pressure

Pressure
Controls

LE

Specifications

Measured when valve is fully open


@ 75% of rated current

200 13.8
JP02C 20
('SS' Coil)

100

0
LPM
GPM

PV33

JP02C 21
('SP' Coil)

JP02C 21
('SS' Coil)

6.9

3.8

7.5

11.4

15.2

18.9

22.8

Flow

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series JP02C 20, 21

Catalog HY15-3502/US

Technical Information

CV

Dimensions

62.7
(2.47)

19.8
(0.78)

Manual Override
(Infinite Control)
3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

See Super Coil


1/2" I.D.
Information For
Terminal Connectors

96.04
(3.78)

FC

7/8 Hex.
27 Nm (20 lb. ft.)
Torque

PC

3/4-16 UNF

Pressure
Controls

(3)

42.5
(1.67)

LM
Load/Motor
Controls

33.8
(1.33)

Flow
Controls

5.54
(0.22)

XXVDC XXW
CCX XXX H

PAT.XXXXXXX
MADEINU.S.A.

39.6
(1.56)

SH
Shuttle
Valves

13.21
(0.52)

Check
Valves

Millimeters (Inches)

(2)

14.2
(0.56)

THIRD-ANGLE
PROJECTION

Logic
Elements

LE

DC
Directional
Controls

Ordering Information

Code Override Option


0

Not Required

Detented M.O.
(Infinite Control)

Coil
Voltage

Coil
Termination

Body
Material

Code Coil Voltage

Code Body Material

Nitrile / Buna-N (Std.)


(SK30105N-1)

Omit Without Coil


D012 12 VDC

Omit Steel
A Aluminum

Fluorocarbon /
(SK30105V-1)

D024 24 VDC

Code Flow Variation


Omit Standard Up to 20%
of Rated Flow
L

Low Variation
(7% of Rated Flow)

Code Coil Type


Omit Without Coil

Code Filter Screen


0 Not Available

Coil
Type

Code Seals / Kit No.

Standard (SS Coil)


15 LPM (4 GPM)
High Flow (SP Coil)
23 LPM (6 GPM)

Flow
Variation

SS
SP

Super Coil - 14 Watts


Super Coil - 19 Watts

Code Coil Termination


Omit Without Coil
D
A

DIN Plug Face


Amp Jr. Timer*

Dual Lead Wire*

LS
H

Sealed Lead Wire*


Molded Deutsch*

Port
Size

MV

SV

Code Port Size Body Part No.


Omit Cartridge Only
4P

1/4 NPTF (B08-3-*4P)

4T
6T

SAE-4
SAE-6

6B

3/8 BSPG (B08-3-*6B)

(B08-3-*4T)
(B08-3-*6T)

* Add A for aluminum, omit for steel.

PV

CE

See Super Coil 1/2 I.D.


*DC Only

BC

60 Mesh Screen on
Port 2

Bodies &
Cavities

21

Seals

TD
Technical
Data

21

Filter
Screen

Solenoid
Valves

Code Style (Maximum


Regulated Flow)
20 Low Flow (SS Coil)
7.5 LPM (2 GPM)

Override
Option

Proportional
Valves

Style

Coils &
Electronics

08 Size
Proportional
Valve

Manual
Valves

JP02C

PV34

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Flow Regulator Valve


Series HP04C 21

CV

General Description

LM
Load/Motor
Controls

FC
Flow
Controls

PC

Pressure
Controls

Analog Proportional Partially Pressure Compensated


Flow Regulator regulates flow proportionally to the input
solenoid current.
A low cost valve designed to be used in applications
where fine pressure compensation is not required.
One piece cartridge housing ensures internal
concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
affecting performance.
Nonmagnetic spool and housing assembly
Factory-adjusted low variation option (Model L) is
available for applications where low variation of flow from
valve to valve is essential at a given current or when an
external pressure compensator is used.

LE
Logic
Elements

DC
Directional
Controls

MV
Manual
Valves
Solenoid
Valves
Proportional
Valves

CE

Rated Flow
2 to 1 @
210 Bar (3000 PSI)

Standard (SS Coil)


30 LPM (8 GPM)
High Flow (SP Coil)
36 LPM (9.5 GPM)

Preferable Input
Port For Best
Hysteresis

Port 1

Hysteresis @
100 Hz PWM

<10%

Cracking Pressure

21% of Rated Current (Standard)


17% of Rated Current (High Flow)

(2)

(1)

Variation of Flow
@ 35% of Rated
Current & Constant
P Maintained By
Pressure
Compensator

Standard Model
Up To 5% Of Rated Flow
Model L
2% Of Rated Flow

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Flow vs. Input Current


GPM LPM
16 60.8

12

Hydraulic Oil 150 SSU @ 100F (32 cSt)

45.6
'SP' Coil

30.4
'SS' Coil

15.2

0
20

40

60

80

100

Input Current (%)

Flow Regulation

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

TD

Approx. Weight

.12 kg (.26 lbs.)

Technical
Data

Coils &
Electronics

Fluid
Compatibility/
Viscosity

Cavity

C10-2
(See BC Section for more details)

BC

(2)

Performance Curves
PWM Current Regulator Recommended

Specifications

SV

PV

(1)

Flow

Shuttle
Valves

Features

GPM LPM
16 60.8

Hydraulic Oil 150 SSU @ 100F (32 cSt)


Measured 75% of rated
current with 'SP' Coil

12

45.6
2 to 1

Flow

Check
Valves

SH

2 Way, Normally Closed, Proportional Flow Regulator


Valve. Partially Pressure Compensated. For additional
information see Technical Tips on pages PV1-PV6.

30.4
1 to 2

15.2

Bodies &
Cavities

0
Bar
PSI

PV35

35

70

105

140

175

210

500

1000

1500

2000

2500

3000

Pressure

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series HP04C 21

Catalog HY15-3502/US

Technical Information

CV

Dimensions

4.0
Stroke
(0.16)

66.5
(2.62)

Manual Override
(Infinite Control)

Shuttle
Valves

7.88
(0.31)
3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

36.0
(1.43)

FC

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

96.5
(3.80)

1 Hex.
30 Nm (22 lb. ft.)
Torque

Pressure
Controls

PC

7/8-14 UNF

33.3
(1.31)

LM

Flow
Controls

5.60
(0.22)

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

SH

22.0
(0.86)

Load/Motor
Controls

13.72
(0.54)

Check
Valves

Millimeters (Inches)

(2)

15.8
(0.62)

Logic
Elements

LE
(1)

Ordering Information

21
21

Standard (SS Coil)


30 LPM (8 GPM)

Seals

Code Seals / Kit No.


N
V

High Flow (SP Coil)


36 LPM (9.5 GPM)

Nitrile / Buna-N (Std.)


(SK30503N-1)
Fluorocarbon /
(SK30503V-1)

Code Flow Variation


Code Override Option
0
5

Not Required
Detented M.O.
(Infinite Control)

Code Filter Screen


0 Not Available

Omit Standard Up to 5%
of Current
L Low Variation
(2% of Current Flow)
Code Coil Type
Omit Without Coil
SS
SP

Super Coil - 18 Watts


Super Coil - 28 Watts

Opening
Point
Variation

Coil
Type

Coil
Voltage

Coil
Termination

Body
Material

Code Coil Voltage

Code Body Material

Omit Without Coil

Omit Steel

D012 12 VDC
D024 24 VDC

Aluminum

Code Port Size


Code Coil Termination
Omit Without Coil
D

DIN Plug Face

A
L

Amp Jr. Timer*


Dual Lead Wire*

LS

Sealed Lead Wire*

Molded Deutsch*

See Super Coil 5/8 I.D.


*DC Only

Port
Size

Manual
Valves

Filter
Screen

SV
Solenoid
Valves

Code Style (Maximum


Regulated Flow)

Override
Option

Body Part No.

Omit
4P
6P
8P
6T
8T
T8T

Cartridge Only
1/4 NPTF (B10-2-*4P)
3/8 NPTF (B10-2-*6P)
1/2 NPTF (B10-2-*8P)
SAE-6
(B10-2-*6T)
SAE-8
(B10-2-*8T)
SAE-8
(B10-2-T8T)

6B

3/8 BSPG (B10-2-*6B)

* Add A for aluminum, omit for steel.


Steel body only.

PV
Proportional
Valves

Style

CE
Coils &
Electronics

10 Size
Proportional
Valve

MV

BC
Bodies &
Cavities

21

TD
Technical
Data

HP04C

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

PV36

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series JP04C 21

Catalog HY15-3502/US

Technical Information
CV

General Description
Check
Valves

SH

2 Way, Normally Closed, Proportional Flow Regulator


Valve. Pressure Compensated. For additional information see Technical Tips on pages PV1-PV6.

LM

One piece cartridge housing ensures internal


concentricity

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Load/Motor
Controls

Shuttle
Valves

Features

FC
Flow
Controls

(3)
(2)

Nonmagnetic spool and housing assembly


(2)

Factory-adjusted low variation option (Model L) is


available for applications where low variation of flow from
valve to valve is essential at a given current.

(3)

Port (1)
Is Not Used

PC
Pressure
Controls

Specifications

21

DC
Directional
Controls

MV
Manual
Valves

SV
Solenoid
Valves

PV
Proportional
Valves

CE
Coils &
Electronics

BC

Maximum Input
Pressure At Port 2

210 Bar (3000 PSI)

Minimum Pressure
Differential

21
21

Maximum Internal
Leakage

780 cc (46 cu. in.)


@ 210 Bar (3000 PSI)

Hysteresis @
100 Hz PWM

7%

Cracking Pressure

25% of Input Signal

Variation of Flow
@ 35% of Rated
Current

Standard Model
Up To 20% Of Rated Flow
Model L
7% Of Rated Flow

Cartridge Material
Operating Temp.
Range/Seals

"SP" Coil

30.3

15.1

"SS" Coil

13.8 Bar (200 PSI) Standard


20.7 Bar (300 PSI) High Flow

0
20

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

TD

Approx. Weight

.13 kg (.28 lbs.)

Cavity

60

80

100

Flow Regulation (Measured 75% of Rated Current)

All parts steel. All operating


parts hardened steel.
-40C to +93.3C (Nitrile)
(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

40

Input Current (%)

GPM LPM

Technical
Data

Bodies &
Cavities

Fluid
Compatibility/
Viscosity

Hydraulic Oil 150 SSU @ 100F (32 cSt)

GPM LPM
12 45.4

30 LPM (8 GPM)
Standard (SS Coil)
36 LPM (9.5 GPM)
High Flow (SP Coil)

Flow

21

Flow

Logic
Elements

Rated Flow

Flow vs. Input Signal

12

45.4

30.3

15.1

Hydraulic Oil 150 SSU @ 100F (32 cSt)

JP04C 21 ("SP" Coil)

JP04C 21 ("SS" Coil)

0
Bar
PSI

35

70

105

140

175

210

500

1000

1500

2000

2500

3000

Pressure

Pressure Drop vs. Flow


PSI Bar

Hydraulic Oil 150 SSU @ 100F (32 cSt)

300 20.7

Pressure

LE

Performance Curves
PWM Current Regulator Recommended

Measured when valve is fully open


@ 75% of rated current

200 13.8
100

'SP'
Coil

6.9
'SS' Coil

0
LPM

3X
(See BC Section for more details)

GPM

PV37

7.6

15.2

22.7

30.4

37.8

45.0

10

12

Flow

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series JP04C 21

Catalog HY15-3502/US

Technical Information

CV

Dimensions

66.5
(2.62)

Manual Override
(Infinite Control)

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

SH

36.0
(1.43)

Load/Motor
Controls

LM

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

Flow
Controls

115.7
(4.55)

FC

1 Hex.
30 Nm (22 lb. ft.)
Torque

PC
Pressure
Controls

7/8-14 UNF
(3)
51.79
(2.04)

LE

(2)

17.4
(0.68)

THIRD-ANGLE
PROJECTION

NOTE: Requires 3X Cavity

Directional
Controls

DC

Ordering Information

Override
Option

Code Style (Maximum


Regulated Flow)
21
21

Seals

Code Filter Screen

Standard (SS Coil)


30 LPM (8 GPM)
High Flow (SP Coil)
36 LPM 9.5 GPM)

Not Required

60 Mesh Screen on
Port 2

Code Seals / Kit No.


N Nitrile / Buna-N (Std.)
(SK30106N-1)

Code Override Option


0

Filter
Screen

Not Required

Detented M.O.
(Infinite Control)

Fluorocarbon /
(SK30106V-1)

Flow
Variation

Coil
Type

Coil
Voltage

Code Flow Variation


Omit Standard Up to 20%
of Rated Flow
L Low Variation
(7% of Rated Flow)
Code Coil Type
Omit Without Coil
SS

Super Coil - 18 Watts

SP

Super Coil - 28 Watts

Coil
Termination

Manual
Valves

Style

Code Coil Voltage


Omit Without Coil

SV

D012 12 VDC
D024 24 VDC
Code Coil Termination
Omit Without Coil
D

DIN Plug Face

A
L

Amp Jr. Timer*


Dual Lead Wire*

LS

Sealed Lead Wire*

Molded Deutsch*

See Super Coil 5/8 I.D.


*DC Only

BC

Code Body Material

TD

553 1/2 SAE

Aluminum

554 3/8 BSP

Steel

Technical
Data

Code Porting

Porting

CE

Body Material

LB10
Line Body

PV

Bodies &
Cavities

Order Bodies Separately

Solenoid
Valves

10 Size
Proportional
Valve

MV

Proportional
Valves

21

Coils &
Electronics

JP04C

Logic
Elements

5.51
(0.22)

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

22.0
(0.86)

Shuttle
Valves

13.21
(0.52)

Check
Valves

Millimeters (Inches)

PV38

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Flow Regulator Valve


Series DFA125C21

CV

General Description
Check
Valves

SH

2 Way, Normally Closed, Proportional Flow Regulator


Valve. Pressure Compensated. For additional information see Technical Tips on pages PV1-PV6.

LM

One piece cartridge housing ensures internal


concentricity

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Load/Motor
Controls

Shuttle
Valves

Features

(3)

(2)

FC
Flow
Controls

(2)

NOTE:
This valve will be available January 1, 2011.

(3)

Port (1)
Is Not Used

PC
Pressure
Controls

Performance Curves
PWM Current Regulator Recommended

Specifications

Pressure Compensation of Regulated Flow

LE

Directional
Controls

MV

Maximum Input
Pressure At Port 2

210 Bar (3000 PSI)

Minimum Pressure
Differential

20.7 Bar (300 PSI)

Maximum Internal
Leakage

GPM LPM
20 76.0

56.8 LPM (15 GPM)


Requires (SP Coil)

Flow

Logic
Elements

DC

Rated Flow @ 75%


of Rated Current

Manual
Valves

>15%

34.2

22.8

Cartridge Material

All parts steel. All operating


parts hardened steel.

11.4
Bar

0
PSI

Proportional
Valves

Flow

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Coils &
Electronics

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Bodies &
Cavities

Approx. Weight

.40 kg (.89 lbs.)

Cavity

C12-3L
(See BC Section for more details)

140

210

2000

3000

Load Pressure

15

57.0

12

45.6

34.2

22.8

Hydraulic Oil 150 SSU @ 100F (32 cSt)

11.4
0
25

Fluid
Compatibility/
Viscosity

70
1000

Flow vs. Input Current


GPM LPM
20 76.0

BC

TD

568 cc (35 cu. in.)


@ 210 Bar (3000 PSI)

50

75

Input Current (%)

Pressure Drop vs. Flow (Through cartridge only)


PSI

Pressure Differential

Solenoid
Valves

CE

45.6

SV

PV

57.0

12

Hysteresis @
100 Hz PWM

Operating Temp.
Range/Seals

15

Hydraulic Oil 150 SSU @ 100F (32 cSt)

Technical
Data

PV39

Bar

200 13.9

100

Hydraulic Oil 150 SSU @ 100F (32 cSt)

2-3 ENERGIZED
@ 75% of Rated Current

6.9

0
LPM
0
GPM

15.2

30.4

45.5

60.8

12

16

Flow (Q)

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series DFA125C21

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)
Check
Valves

Dimensions

15.7 (0.62)
2.5
(0.10)

66.5
(2.62)

Manual Override
(Infinite Control)

Finger Tight to
4.1 Nm (3 lb. ft.)
Max.

SH

36.0
(1.43)

Load/Motor
Controls

LM

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

FC
Flow
Controls

99.5
(3.92)

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

22.0
(0.86)

Shuttle
Valves

8.7
(0.34)

4.8
(0.19)

1-1/4" Hex.
74 Nm (55 lb. ft.)
Torque

PC
Pressure
Controls

175.8
(6.92)

19.1
(0.75)
1-1/16-12UN-2A
Thread

LE

(3)

Logic
Elements

76.2
(3.00)
(2)

(1)

22.2
(0.87)

THIRD-ANGLE
PROJECTION

Directional
Controls

DC

12 Size
Proportional
Valve

Style

Override
Option

Code Style (Maximum


Regulated Flow)
21

Seals

Code Seals / Kit No.


N

High Flow (SP Coil)


56.8 LPM (15 GPM)

Nitrile / Buna-N (Std.)


(SK12-3LN)
Fluorocarbon /
(SK12-3LV)

Code Override Option


Omit Not Available
S

Coil
Type

Standard M.O.
(Infinite Control)

Coil
Voltage

NOTE:
This valve will be available
January 1, 2011.

Coil
Termination

Code Coil Type

Code Coil Termination

Omit Without Coil

Omit Without Coil

SP

Super Coil - 28 Watts

D
A

DIN Plug Face


Amp Jr. Timer*

Code Coil Voltage

Dual Spade*

Omit Without Coil


D012 12 VDC

L
LS

Dual Lead Wire*


Sealed Lead Wire*

Molded Deutsch*

D024 24 VDC

See Super Coil 5/8 I.D.


*DC Only

12T

12 Size

3-Way
Long Cavity

Body
Material

Port Size

Bodies &
Cavities

3L

Aluminum

CE

TD
Technical
Data

B12

PV

BC

Order Bodies Separately

Code Body Material

SV
Solenoid
Valves

21

Proportional
Valves

DFA125C

Coils &
Electronics

Ordering Information

Manual
Valves

MV

Code Port Size


12T SAE - 12

PV40

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Flow Regulator Valve


Series HP02P 21

CV

General Description

LM
Load/Motor
Controls

FC
Flow
Controls

PC

Pressure
Controls

Analog Proportional Partially Pressure Compensated


Flow Regulator regulates flow proportionally to the input
solenoid current
The valve is designed to be used in applications where
fine pressure compensation is not required and an
economical solution is important
One piece cartridge housing ensures internal
concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
affecting performance.
Nonmagnetic spool and housing assembly
Factory-adjusted low variation option (Model L) is
available for applications where low variation of flow from
valve to valve is essential at a given current or when an
external pressure compensator is used.

LE

Directional
Controls

Preferable Input
Port For Best
Hysteresis

Port 1

MV

Hysteresis @
100 Hz PWM

<10%

Variation of Flow
@ 35% of Rated
Current & Constant
P Maintained By
Pressure
Compensator

Standard Model
Up To 20% Of Rated Flow
Model L
7% Of Rated Flow

Cartridge Material

All parts steel. All operating


parts hardened steel.

Proportional
Valves

Logic
Elements

2 to 1 19 LPM (5 GPM)

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

CE

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Approx. Weight

.08 kg (.17 lbs.)

Cavity

2X
(See BC Section for more details)

Manual
Valves

SV
Solenoid
Valves

PV

Coils &
Electronics

BC

(1)
(1)

(2)

Performance Curves
PWM Current Regulator Recommended

Specifications
Rated Flow @
210 Bar (3000 PSI)

DC

(2)

Flow vs. Input Current


GPM LPM
6 22.8

Hydraulic Oil 150 SSU @ 100F (32 cSt)

15.2

Flow

Shuttle
Valves

Features

2 to 1 OR 1 to 2

7.6

0
0

20

40

60

80

100

Input Current (%)

Flow Regulation (Measured at De-Energized Coil)


GPM LPM
8 30.4

Hydraulic Oil 150 SSU @ 100F (32 cSt)

2 to 1

22.8
1 to 2

Flow

Check
Valves

SH

2 Way, Normally Open, Proportional Flow Regulator


Valve. Partially Pressure Compensated. For additional
information see Technical Tips on pages PV1-PV6.

15.2

7.6

Bodies &
Cavities

0
Bar

TD

PSI

35

70

105

140

175

210

500

1000

1500

2000

2500

3000

Pressure

Technical
Data

PV41

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series HP02P 21

Catalog HY15-3502/US

Technical Information

CV

Dimensions

Check
Valves

Millimeters (Inches)

62.7
(2.47)

SH

Manual Override
(Infinite Control)
3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

33.8
(1.33)

FC

See Super Coil


1/2" I.D.
Information For
Terminal Connectors

82.04
(3.23)

7/8 Hex.
27 Nm (20 lb. ft.)
Torque

PC
Pressure
Controls

28.5
(1.12)

LM

Flow
Controls

5.59
(0.22)

XXVDC XXW
CCX XXX H

PAT.XXXXXXX
MADEINU.S.A.

39.6
(1.56)

Shuttle
Valves

19.8
(0.78)

Load/Motor
Controls

13.21
(0.52)

3/4-16 UNF
(2)

Logic
Elements

LE
(1)

15.9
(0.63)

NOTE: Requires 2X Cavity

Ordering Information

Override
Option

High Flow (SP Coil)


19 LPM (5 GPM)

Not Available

Code Seals / Kit No.


N

Code Override Option


0 Not Required
5

Seals

Code Filter Screen

Code Style (Maximum


Regulated Flow)
21

Filter
Screen

Detented M.O.
(Infinite Control)

Nitrile / Buna-N (Std.)


(SK30076N-1)
Fluorocarbon /
(SK30076V-1)

Flow
Variation

Coil
Type

Coil
Voltage

Coil
Termination

Code Flow Variation

Code Coil Voltage

Omit Standard Up to 20%


of Rated Flow
L Low Variation
(7% of Rated Flow)

D012 12 VDC
D024 24 VDC

Code Coil Type

Code Coil Termination


Omit Without Coil

Omit Without Coil


SP

Super Coil - 19 Watts

Omit Without Coil

DIN Plug Face

A
L

Amp Jr. Timer*


Dual Lead Wire*

LS

Sealed Lead Wire*

Molded Deutsch*

Bodies &
Cavities

BC

Code Body Material

TD

513 3/8 SAE

Aluminum

515 1/4 BSP

Steel

Technical
Data

Code Porting

Porting

CE

Body Material

LB10
Line Body

SV

PV

See Super Coil 1/2 I.D.


*DC Only

Order Bodies Separately

Manual
Valves

Style

Solenoid
Valves

08 Size
Proportional
Valve

MV

Proportional
Valves

21

Coils &
Electronics

HP02P

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

PV42

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series JP02P 20, 21

Catalog HY15-3502/US

Technical Information
CV

General Description
Check
Valves

SH

2 Way, Normally Open, Proportional Flow Regulator


Valve. Pressure Compensated. For additional information see Technical Tips on pages PV1-PV6.

LM

One piece cartridge housing ensures internal


concentricity

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Nonmagnetic spool and housing assembly

Load/Motor
Controls

Shuttle
Valves

Features

FC

(3)

(2)

Flow
Controls

Factory-adjusted low variation option (Model L) is


available for applications where low variation of flow from
valve to valve is essential at a given current.

(2)

Port (1)
Is Not Used

(3)

PC
Pressure
Controls

Specifications

21

DC

210 Bar (3000 PSI)

Minimum Pressure
Differential

20
21

Maximum Internal
Leakage

570 cc (35 cu. in.)


@ 210 Bar (3000 PSI)

Hysteresis @
100 Hz PWM

<3%

SV
Solenoid
Valves

Directional
Controls

Maximum Input
Pressure At Port 2

Variation of Flow
@ 35% of Rated
Current

Standard Model
Up To 20% Of Rated Flow
Model L
7% Of Rated Flow

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

MV
Manual
Valves

PV
Proportional
Valves

CE
Coils &
Electronics

BC
Bodies &
Cavities

TD

Hydraulic Oil 150 SSU @ 100F (32 cSt)

GPM LPM
6 22.8

9.5 LPM (2.5 GPM)


Standard (SS Coil)
19 LPM (5 GPM)
High Flow (SP Coil)

Flow

20

15.2
JP02P 21

7.6
JP02P 20

6.9 Bar (150 PSI) Standard


20.7 Bar (300 PSI) High Flow

0
20

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Technical
Data

Approx. Weight

.08 kg (.17 lbs.)

Cavity

C08-3
(See BC Section for more details)

60

80

100

Flow Regulation (Measured 75% of Rated Current)


GPM LPM

Fluid
Compatibility/
Viscosity

40

Input Current (%)

Flow

Logic
Elements

Rated Flow

Flow vs. Input Current

22.8

15.2

7.6

Hydraulic Oil 150 SSU @ 100F (32 cSt)

JP02P 21

JP02P 20

0
Bar
PSI

35

70

105

140

175

210

500

1000

1500

2000

2500

3000

Pressure

Pressure Drop vs. Flow


PSI Bar

Hydraulic Oil 150 SSU @ 100F (32 cSt)

300 20.7

Pressure

LE

Performance Curves
PWM Current Regulator Recommended

Measured at
de-energized coil

200 13.8
100

0
LPM
GPM

PV43

JP02P 21

JP02P 20

6.9

3.8

7.5

11.4

15.2

18.9

22.8

Flow

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series JP02P 20, 21

Catalog HY15-3502/US

Technical Information

CV

13.21
(0.52)

Check
Valves

Millimeters (Inches)
62.7
(2.47)

19.8
(0.78)

XXVDC XXW
CCX XXX H

See Super Coil


1/2" I.D.
Information For
Terminal Connectors

96.04
(3.78)

FC

7/8 Hex.
27 Nm (20 lb. ft.)
Torque

PC
Pressure
Controls

3/4-16 UNF
(3)

42.5
(1.67)

LM

Flow
Controls

PAT.XXXXXXX
MADEINU.S.A.

5.54
(0.22)

33.8
(1.33)

Load/Motor
Controls

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque
39.6
(1.56)

SH
Shuttle
Valves

Manual Override
(Infinite Control)

(2)

LE

14.2
(0.56)
THIRD-ANGLE
PROJECTION

Logic
Elements

Dimensions

Directional
Controls

DC

Ordering Information

JP02P

Code Override Option


0

Not Required

Detented M.O.
(Infinite Control)

Code Filter Screen


0
1

Not Required
60 Mesh Screen on
Port 2

Fluorocarbon /
(SK30105V-1)

Code Flow Variation


Omit Standard Up to 20%
of Rated Flow
L

Low Variation
(7% of Rated Flow)

Code Coil Type


Omit Without Coil
SS Super Coil - 14 Watts
SP

Coil
Type

Code Coil Voltage


Omit Without Coil
D012 12 VDC

Coil
Voltage

Coil
Termination

Body
Material

Port
Size

Code Body Material


Omit Steel
A

Aluminum

D024 24 VDC
Code Port Size
Code Coil Termination
Omit Without Coil
D DIN Plug Face
A

Amp Jr. Timer*

L
LS

Dual Lead Wire*


Sealed Lead Wire*

Molded Deutsch*

Body Part No.

Omit Cartridge Only


4P
4T
6T

1/4 NPTF (B08-3-*4P)


SAE-4
(B08-3-*4T)
SAE-6
(B08-3-*6T)

6B

3/8 BSPG (B08-3-*6B)

* Add A for aluminum, omit for steel.

See Super Coil 1/2 I.D.


*DC Only

SV
Solenoid
Valves

Code Seals / Kit No.


N Nitrile / Buna-N (Std.)
(SK30105N-1)

Flow
Variation

PV
Proportional
Valves

21

Standard (SS Coil)


9.5 LPM (2.5 GPM)
High Flow (SP Coil)
19 LPM (5 GPM)

Seals

CE
Coils &
Electronics

20

Filter
Screen

BC

Super Coil - 19 Watts

Bodies &
Cavities

Code Style (Maximum


Regulated Flow)

Override
Option

Manual
Valves

MV
Style

TD
Technical
Data

08 Size
Proportional
Valve

PV44

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Flow Regulator Valve


Series HP04P 21

CV

General Description

LM
Load/Motor
Controls

FC
Flow
Controls

PC
Pressure
Controls

LE

Analog Proportional Partially Pressure Compensated


Flow Regulator regulates flow proportionally to the input
solenoid current
The valve is designed to be used in applications where
fine pressure compensation is not required and an
exonomical solution is important
One piece cartridge housing ensures internal
concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
affecting performance.
Nonmagnetic spool and housing assembly
Factory-adjusted low variation option (Model L) is
available for applications where low variation of flow from
valve to valve is essential at a given current or when an
external pressure compensator is used.

Rated Flow @
210 Bar (3000 PSI)

23 LPM (6 GPM)

Hysteresis @
100 Hz PWM

<10%

Closing Point

65% of Rated Current

Variation of
Closing Point

Standard Model
Up To 5% Of Rated Current
Model L
2% Of Rated Current

Directional
Controls

Logic
Elements

DC

(2)
(1)

Flow vs. Input Current

MV

GPM LPM
12 45.5

Manual
Valves

30.4

15.2

Hydraulic Oil 150 SSU @ 100F (32 cSt)

Solenoid
Valves

20

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

40

60

80

100

Input Current (%)

Flow Regulation

PV
Proportional
Valves

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

BC

Filtration

ISO Code 16/13,


SAE Class 4 or better

Approx. Weight

.12 kg (.26 lbs.)

TD

Cavity

C10-2
(See BC Section for more details)

Coils &
Electronics

Fluid
Compatibility/
Viscosity

Bodies &
Cavities

CE

(2)

Performance Curves
PWM Current Regulator Recommended

Specifications

SV

(1)

Flow

Shuttle
Valves

Features

GPM LPM
12 45.5

Hydraulic Oil 150 SSU @ 100F (32 cSt)


Measured at de-energized coil

30.4

15.2

Flow

Check
Valves

SH

2 Way, Normally Open, Proportional Flow Regulator


Valve. Partially Pressure Compensated. For additional
information see Technical Tips on pages PV1-PV6.

0
Bar
PSI

Technical
Data

PV45

42

84

126

168

210

600

1200

1800

2400

3000

Pressure Differential

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series HP04P 21

Catalog HY15-3502/US

Technical Information

CV

Dimensions

66.5
(2.62)

Manual Override
(Infinite Control)

Shuttle
Valves

8.38
(0.33)
3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque
XXVDC XXW
CAX XXX H

36.0
(1.43)

FC

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

97.3
(3.83)

1 Hex.
30 Nm (22 lb. ft.)
Torque

PC
Pressure
Controls

5.59
(0.22)

LM

Flow
Controls

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

SH

22.0
(0.86)

Load/Motor
Controls

13.21
(0.52)

Check
Valves

Millimeters (Inches)

7/8-14 UNF
(2)

15.8
(0.62)

Logic
Elements

LE
(1)

Ordering Information

21

High Flow (SP Coil)


30 LPM (8 GPM)

Code Override Option


0 Not Required
5

Detented M.O.
(Infinite Control)

Code Filter Screen


0

Seals

Code Seals / Kit No.


N
V

Nitrile / Buna-N (Std.)


(SK30503N-1)
Fluorocarbon /
(SK30503V-1)

Code Flow Variation


Omit Standard Up to 5%
of Current Flow
L Low Variation
(2% of Current Flow)

Not Available
Code Coil Type
Omit Without Coil
SP

Super Coil - 28 Watts

Opening
Point
Variation

Coil
Type

Coil
Voltage

Coil
Termination

Body
Material

Code Coil Voltage

Code Body Material

Omit Without Coil

Omit Steel

D012 12 VDC
D024 24 VDC

Aluminum

Code Port Size


Code Coil Termination
Omit Without Coil
D

DIN Plug Face

A
L

Amp Jr. Timer*


Dual Lead Wire*

LS

Sealed Lead Wire*

Molded Deutsch*

See Super Coil 5/8 I.D.


*DC Only

Port
Size

Manual
Valves

Filter
Screen

SV
Solenoid
Valves

Code Style (Maximum


Regulated Flow)

Override
Option

Body Part No.

Omit
4P
6P
8P
6T
8T
T8T

Cartridge Only
1/4 NPTF (B10-2-*4P)
3/8 NPTF (B10-2-*6P)
1/2 NPTF (B10-2-*8P)
SAE-6
(B10-2-*6T)
SAE-8
(B10-2-*8T)
SAE-8
(B10-2-T8T)

6B

3/8 BSPG (B10-2-*6B)

* Add A for aluminum, omit for steel.


Steel body only.

PV
Proportional
Valves

Style

CE
Coils &
Electronics

10 Size
Proportional
Valve

MV

BC
Bodies &
Cavities

21

TD
Technical
Data

HP04P

DC
Directional
Controls

THIRD-ANGLE
PROJECTION

PV46

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Flow Regulator Valve


Series JP04P 21

CV

General Description
Check
Valves

SH

2 Way, Normally Open, Proportional Flow Regulator


Valve. Pressure Compensated. For additional information see Technical Tips on pages PV1-PV6.

LM

One piece cartridge housing ensures internal


concentricity

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

Load/Motor
Controls

Shuttle
Valves

Features

FC
Flow
Controls

(3)

(2)

Nonmagnetic spool and housing assembly


(2)

Factory-adjusted low variation option (Model L) is


available for applications where low variation of flow from
valve to valve is essential at a given current.

(3)
Port (1)
Is Not Used

PC
Pressure
Controls

Specifications

DC

Maximum Input
Pressure At Port 2

210 Bar (3000 PSI)

Minimum Pressure
Differential

14 Bar (200 PSI)

MV

Maximum Internal
Leakage

780 cc (46 cu. in.)


@ 210 Bar (3000 PSI)

Manual
Valves

Hysteresis @
100 Hz PWM

7%

Variation of Flow
@ 35% of Rated
Current

Standard Model
Up To 20% Of Rated Flow
Model L
7% Of Rated Flow

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

SV
Solenoid
Valves

PV
Proportional
Valves

CE
Coils &
Electronics

Fluid
Compatibility/
Viscosity

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

BC
Bodies &
Cavities

Approx. Weight

.13 kg (.28 lbs.)

Cavity

3X
(See BC Section for more details)

Hydraulic Oil 150 SSU @ 100F (32 cSt)

GPM LPM
9 34.2

Flow

36 LPM (9.5 GPM)


High Flow (SP Coil)

22.7

11.4
0
20

40

60

80

100

Input Current (%)

Flow Regulation
GPM LPM

Flow

Rated Flow

Directional
Controls

Logic
Elements

Flow vs. Input Current

34.2

22.7

11.4

Hydraulic Oil 150 SSU @ 100F (32 cSt)

0
Bar
PSI

35

70

105

140

175

210

500

1000

1500

2000

2500

3000

Pressure

Pressure Drop vs. Flow


PSI Bar

Hydraulic Oil 150 SSU @ 100F (32 cSt)

300 20.7

Pressure

LE

Performance Curves
PWM Current Regulator Recommended

TD

Measured at
de-energized coil

200 13.8
100

6.9

Technical
Data

0
LPM
GPM

PV47

7.6

15.2

22.7

30.4

37.8

45.0

10

12

Flow

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series JP04P 21

Catalog HY15-3502/US

Technical Information

CV

Dimensions

66.5
(2.62)

Manual Override
(Infinite Control)

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

SH

36.0
(1.43)

Load/Motor
Controls

LM

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

Flow
Controls

115.7
(4.55)

FC

1 Hex.
30 Nm (22 lb. ft.)
Torque

PC
Pressure
Controls

7/8-14 UNF
(3)
51.79
(2.04)

LE

(2)

17.4
(0.68)

THIRD-ANGLE
PROJECTION

NOTE: Requires 3X Cavity

Directional
Controls

DC

Ordering Information

Override
Option

Code Style (Maximum


Regulated Flow)
21

Seals

Code Filter Screen

High Flow (SP Coil)


36 LPM 9.5 GPM)

Code Override Option


0
5

Filter
Screen

Not Required

60 Mesh Screen on
Port 2

Code Seals / Kit No.


N Nitrile / Buna-N (Std.)
(SK30106N-1)

Not Required
Detented M.O.
(Infinite Control)

Fluorocarbon /
(SK30106V-1)

Flow
Variation

Coil
Type

Coil
Voltage

Code Flow Variation


Omit Standard Up to 20%
of Rated Flow
L Low Variation
(7% of Rated Flow)
Code Coil Type
Omit Without Coil
SP

Super Coil - 28 Watts

Coil
Termination

Manual
Valves

Style

Code Coil Voltage


Omit Without Coil

SV

D012 12 VDC
D024 24 VDC
Code Coil Termination
Omit Without Coil
D

DIN Plug Face

A
L

Amp Jr. Timer*


Dual Lead Wire*

LS

Sealed Lead Wire*

Molded Deutsch*

See Super Coil 5/8 I.D.


*DC Only

BC

Code Body Material

TD

553 1/2 SAE

Aluminum

554 3/8 BSP

Steel

Technical
Data

Code Porting

Porting

CE

Body Material

LB10
Line Body

PV

Bodies &
Cavities

Order Bodies Separately

Solenoid
Valves

10 Size
Proportional
Valve

MV

Proportional
Valves

21

Coils &
Electronics

JP04P

Logic
Elements

5.51
(0.22)

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

22.0
(0.86)

Shuttle
Valves

13.21
(0.52)

Check
Valves

Millimeters (Inches)

PV48

Parker Hannifin Corporation


Hydraulic Cartridge Systems

N.O. Proportional Flow Control Valve


Series DF122N

Catalog HY15-3502/US

Technical Information
CV

General Description

Shuttle
Valves

Check
Valves

SH

Normally Open Proportional Flow Control Valve.


For additional information see Technical Tips
on pages PV1-PV6.

Features

LM
Load/Motor
Controls

FC

On-off type solenoids


Low hysteresis
PWM signal preferred
Manual override standard

(2)

All external parts zinc plated

Flow
Controls

Out
(2)

(1)

PC
Pressure
Controls

In
(1)

Logic
Elements

Rated Flow
Valve Fully Open

53 LPM (14 GPM)

DC

Maximum Inlet
Pressure

210 Bar (3000 PSI)

Hysteresis
@ 200 Hz PWM

4%

Frequency

100 - 400 Hz (200 Hz Preferred)

Solenoid
Valves

PV

Cartridge Material
Operating Temp.
Range/Seals

12 VDC
2.45A

Bar
20.7

200

13.8

100

6.9

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Proportional
Valves

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Coils &
Electronics

Approx. Weight

.32 kg (0.7 lbs.)

Cavity

C12-2
(See BC Section for more details)

BC

Form Tool

Rougher
Finisher

None
NFT12-2F

Bodies &
Cavities

Note: 4.1 Bar (60psi) is required at port 1 to fully return Manual


override.

Pressure Drop vs. Flow @ No Current


Hydraulic Oil 150 SSU @ 100 F (32 cSt)

0
LPM
0
GPM

19
5

38
10

57
15

76
20

Flow (Q)

All parts steel. All operating


parts hardened steel.

Fluid
Compatibility/
Viscosity

CE

PSI
300

24VDC
1.23A

GPM LPM
30 114

Flow (Q)

Manual
Valves

SV

Maximum Control
Current

20

76

10

38

Flow vs. Inlet Pressure @ No Current


Hydraulic Oil 150 SSU @ 100 F (32 cSt)

0
Bar
0
PSI

69
1000

207
3000

138
2000

Inlet Pressure
GPM LPM
15
57

Flow (Q)

MV

Performance Curves

Pressure Drop ( P)

Specifications

Directional
Controls

LE

TD

10

38

19

Flow vs. Input Signal (Current)


Hydraulic Oil 150 SSU @ 100 F (32 cSt)

Technical
Data

25

50

75

Percent of Maximum Control Current

PV49

Parker Hannifin Corporation


Hydraulic Cartridge Systems

100

N.O. Proportional Flow Control Valve


Series DF122N

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)

56.0
(2.20)

Check
Valves

Dimensions

48.0
(1.90)

SH
Shuttle
Valves

Finger
Tight
Torque
See DS Coil 1" I.D.
Information For
Terminal Connectors

Load/Motor
Controls

60.0
(2.35)

17
(.66)

FC
Flow
Controls

161.0
(6.33)

LM

1-1/4" Hex.
29 Nm (21 lb. ft.)
Torque

PC
41.3
(1.63)

Pressure
Controls

(2)
1-1/16 - 12 UNF-2A
Thread

22.2
(.87)

THIRD-ANGLE
PROJECTION

LE
Logic
Elements

(1)

Directional
Controls

DC

Ordering Information

DF122N14
Override
Options

Seals

Coil
Voltage

Coil
Wattage

Coil
Termination

Body
Material

Port
Size

Manual
Valves

12 Size Normally
Open Proportional
Flow Control Valve

MV

Code Coil Termination

Code Body Material

Omit Push Type with


Extenden Rod

Omit Cartridge without Coil


D012 12 VDC

Omit Cartridge without Coil


D DIN

Omit Steel
A Aluminum

D024 24 VDC
Code Coil Wattage

Dual Wire

See DS Coil 1 I.D.

Omit Cartridge
without Coil
H High Watt

Code Port Size Body Part No.


12P 3/4 NTPF (B12-2-*12P)
8T SAE - 8
12T SAE - 12

(B12-2-*8T)
(B12-2-*12T)

* Add A for aluminum, omit for steel.

PV

CE
Coils &
Electronics

Fluorocarbon / (SK12-2V)

Dual Spade

BC
Bodies &
Cavities

P
W

TD
Technical
Data

Code Seals / Kit. No.


Omit Nitrile / (SK12-2)

Proportional
Valves

Code Coil Voltage

Solenoid
Valves

SV
Code Override Options

PV50

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series JP04C 31

Catalog HY15-3502/US

Technical Information
CV

General Description

Analog proportional pressure compensated flow control


valve regulates flow proportionally to the input solenoid
current

One piece cartridge housing ensures internal


concentricity

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

LM

Flow
Controls

PC
Pressure
Controls

LE

Logic
Elements
Directional
Controls
Manual
Valves

SV

Proportional
Valves

CE

Rated Inlet Flow

60 LPM (16 GPM)

Rated Regulated
Flow

31
31

Pressure Compensation of Regulated Flow (Port 4)


GPM LPM
10 38.0

26 LPM (7 GPM)
Standard (SS Coil)
30 LPM (8 GPM)
High Flow (SP Coil)

Maximum Input
Pressure At Port 3

210 Bar (3000 PSI)

Minimum Pressure
Differential

31
31

13.8 Bar (200 PSI) Standard


20.7 Bar (300 PSI) High Flow

Maximum Internal
Leakage

780 cc (46 cu. in.)


@ 210 Bar (3000 PSI)

Hysteresis @
100 Hz PWM

7%

Opening Point

Standard
21% of Nominal Amperage
High Flow
17% of Nominal Amperage

Variation of
Opening Point

Standard Model
Up To 50% Of Amperage
Model L
20% Of Amperage

Coils &
Electronics

Operating Temp.
Range/Seals

Not Used
(1)

Performance Curves
PWM Current Regulator Recommended

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)
Mineral-based or synthetic with
lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

TD

Approx. Weight

.14 kg (.31 lbs.)

Technical
Data

Cavity

4C
(See BC Section for more details)

30.4

22.7

15.2

Hydraulic Oil 150 SSU @ 100F (32 cSt)

7.6
Regulated Load Higher
Than By-Pass

By-Pass Load Higher


Than Regulated

0
Bar 210

140

70

70

140

210

PSI 3000

2000

1000

1000

2000

3000

Pressure

Regulated Flow vs. Input Current Stabilized


GPM LPM
10 38.0

Hydraulic Oil 150 SSU @ 100F (32 cSt)

22.8

7.6
0

All parts steel. All operating


parts hardened steel.

Fluid
Compatibility/
Viscosity

BC

(4)
(2)
*Always connect Port (1) to
Port (4) through .039" orifice.

Specifications

Cartridge Material

Bypass
(2)

Factory-adjusted low variation option (Model L) is


available for applications where low variation of flow from
valve to valve is essential at a given current.

Solenoid
Valves

PV

Inlet
(3)

(1)

Nonmagnetic spool and housing assembly

DC

MV

(3)

Flow

Load/Motor
Controls

FC

Reg.
(4)

Flow

Shuttle
Valves

Features

25

50

75

100

Input Current (%)

Pressure Drop vs. Flow at Coil Fully Energized


PSI Bar
300 20.7

Bodies &
Cavities

Pressure

Check
Valves

SH

3 Way, Normally Closed, Proportional Flow Regulator


Valve. Pressure Compensated. For additional information see Technical Tips on pages PV1-PV6.

200 13.9
100

6.9
0
LPM
0
GPM

PV51

Hydraulic Oil 150 SSU @ 100F (32 cSt)

7.5

15.2

22.8

30.4

37.8

45.5

10

12

Flow

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series JP04C 31

Catalog HY15-3502/US

Technical Information

CV
66.5
(2.62)

Manual Override
(Infinite Control)
(Screw Adjust)

13.21
(0.52)
8.38
(0.33)

22.0
(0.86)

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

SH

36.0
(1.43)

Load/Motor
Controls

LM

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

FC

1 Hex.
30 Nm (22 lb. ft.)
Torque

5.59
(0.22)

Flow
Controls

133.4
(5.25)

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

Check
Valves

Millimeters (Inches)

Shuttle
Valves

Dimensions

7/8-14 UNF

Reg. (4)

PC
Pressure
Controls

In (3)
Byp. (2)

15.9
(0.62)

(1)
Ext. Pilot

NOTE: Requires 4C Cavity


THIRD-ANGLE
PROJECTION

Logic
Elements

LE

Directional
Controls

DC

Ordering Information

MV
Override
Option

Code Style (Maximum


Regulated Flow)
31
31

Filter
Screen

Seals

Code Filter Screen


0 Not Available

Standard (SS Coil)


26 LPM (7 GPM)
High Flow (SP Coil)
30 LPM (8 GPM)

Code Seals / Kit No.


N Nitrile / Buna-N (Std.)
(SK30082N-1)
V

Code Override Option

Fluorocarbon /
(SK30082V-1)

Flow
Variation

Coil
Type

Coil
Voltage

Code Flow Variation


Omit Standard Up to 50%
of Opening Amps
L

Low Variation (20%


of Opening Amps)

Code Coil Type


Omit Without Coil

Not Required

SS

Super Coil - 18 Watts

Screw Adjust

SP

Super Coil - 28 Watts

Coil
Termination
Code Coil Voltage
Omit Without Coil

Code Coil Termination

PV

Omit Without Coil


D DIN Plug Face
A

Amp Jr. Timer*

L
LS

Dual Lead Wire*


Sealed Lead Wire*

Molded Deutsch*

Body Material

Bodies &
Cavities

Code Body Material

TD

562 1/2 SAE

Aluminum

563 3/8 BSP

Steel

Technical
Data

LB10
Code Porting

CE

BC

Order Bodies Separately

Porting

SV

D024 24 VDC

D012 12 VDC

See Super Coil 5/8 I.D.


*DC Only

Line Body

Manual
Valves

Style

Solenoid
Valves

10 Size
Proportional
Valve

Proportional
Valves

31

Coils &
Electronics

JP04C

PV52

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Flow Regulator Valve


Series DFA125C31

CV

General Description
Check
Valves

SH

3 Way, Normally Closed, Proportional Flow Regulator


Valve. Pressure Compensated. For additional information see Technical Tips on pages PV1-PV6.

Shuttle
Valves

Features

Analog proportional pressure compensated flow control


valve regulates flow proportionally to the input solenoid
current

One piece cartridge housing ensures internal


concentricity

Coil: Waterproof, hermetically sealed, requires no


ORings; Symmetrical coil can be reversed without
affecting performance.

LM
Load/Motor
Controls

FC
Flow
Controls

Inlet
(3)
Bypass
(2)

(1)
*
(4)
(2)
*Always connect Port (1) to
Port (4) through .039" orifice.

PC

Not Used
(1)

Pressure Compensation of Regulated Flow (Port 4)


75 LPM (20 GPM)

Rated Regulated
Flow

56.8 LPM (15 GPM)


Requires (SP Coil)

Maximum Input
Pressure At Port 3

210 Bar (3000 PSI)

Minimum Pressure
Differential

13.8 Bar (200 PSI)

Directional
Controls

568 cc (35 cu. in.)


@ 210 Bar (3000 PSI)

SV

Hysteresis @
100 Hz PWM

>15%

Solenoid
Valves

Manual
Valves

Maximum Internal
Leakage

GPM LPM
20 76.0

Flow

Logic
Elements

Rated Inlet Flow

15

57.0

12

45.6

34.2

22.8

11.4

Hydraulic Oil 150 SSU @ 100F (32 cSt)

Regulated Load Higher


Than By-Pass

By-Pass Load Higher

Than Regulated
0
Bar 210
140

PSI 3000

2000

70

70

140

210

1000

1000

2000

3000

Pressure

Regulated Flow vs. Input Current Stabilized

Cartridge Material

All parts steel. All operating


parts hardened steel.

PV
Proportional
Valves

Operating Temp.
Range/Seals

GPM LPM
20 76.0

Flow

Pressure
Controls

Specifications

DC

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

15

57.0

12

45.6

34.2

22.8

Hydraulic Oil 150 SSU @ 100F (32 cSt)

11.4
0
25

50

75

Input Current (%)

CE

BC

Filtration

ISO Code 16/13,


SAE Class 4 or better

Technical
Data

Approx. Weight

.45 kg (1.0 lbs.)

Cavity

C12-4L
(See BC Section for more details)

Pressure Drop vs. Flow (Through cartridge only)


PSI Bar
300 20.7

Pressure

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Bodies &
Cavities

Coils &
Electronics

Fluid
Compatibility/
Viscosity

TD

Performance Curves
PWM Current Regulator Recommended

LE

MV

Reg.
(4)

(3)

Hydraulic Oil 150 SSU @ 100F (32 cSt)

200 13.9

100

6.9
0

LPM
0
GPM

PV53

15.2

30.4

45.5

60.8

12

16

Flow (Q)

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Flow Regulator Valve


Series DFA125C31

Catalog HY15-3502/US

Technical Information

CV
Millimeters (Inches)
Check
Valves

Dimensions

15.7 (0.62)
2.5
(0.10)

66.5
(2.62)

Manual Override
(Infinite Control)

Finger Tight to
4.1 Nm (3 lb. ft.)
Max.

SH

36.0
(1.43)

Load/Motor
Controls

LM

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

FC
Flow
Controls

99.5
(3.92)

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

22.0
(0.86)

Shuttle
Valves

8.7
(0.34)

4.8
(0.19)

1-1/4" Hex.
74 Nm (55 lb. ft.)
Torque

Pressure
Controls

PC

19.1
(0.75)

200.3
(7.88)

1-1/16-12UN-2A
Thread

LE

100.6
(3.96)

Logic
Elements

Reg. (4)

In (3)

Directional
Controls

DC
Byp. (2)

(1)
THIRD-ANGLE
PROJECTION

Ext. Pilot

SV

Style

Override
Option

Code Override Option


Omit Not Available
S

Standard M.O.
(Infinite Control)

Seals

Coil
Type

Coil
Voltage

Code Coil Type

Code Coil Termination

Omit Without Coil


SP Super Coil 28 Watts

Omit Without Coil


D DIN Plug Face
A

Amp Jr. Timer*

Code Coil Voltage


Omit Without Coil

S
L

Dual Spade*
Dual Lead Wire*

LS

Sealed Lead Wire*

D012 12 VDC

Molded Deutsch*

D024 24 VDC

See Super Coil 5/8 I.D.


*DC Only

Code Seals / Kit No.


N Nitrile / Buna-N (Std.)
(SK12-4LN)
V

PV

Coil
Termination

Proportional
Valves

12 Size
Proportional
Valve

CE
Coils &
Electronics

B12

4L

12T

12 Size

4-Way
Long Cavity

Body
Material

Port Size

Code Body Material

Fluorocarbon /
(SK12-4LV)

PV54

BC

Order Bodies Separately

Aluminum

Code Port Size


12T SAE - 12

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Bodies &
Cavities

31

TD
Technical
Data

DFA125C

Solenoid
Valves

Ordering Information

Code Style (Maximum


Regulated Flow)
31 High Flow (SP Coil)
56.8 LPM (15 GPM)

Manual
Valves

MV

Proportional Directional Control Valve


Series GP02 51, 51L, 52

Catalog HY15-3502/US

Technical Information
CV

General Description
Check
Valves

SH

4 Way, 3 Position, Proportional Directional Control


Valve. Closed Center Spool. For additional information
see Technical Tips on pages PV1-PV6.

Features

Flow
Controls

PC
Pressure
Controls

LE
Logic
Elements

DC

Specifications
Operating
Pressure

Ports 2, 3 and 4
350 Bar (5000 PSI)
Port 1
210 Bar (3000 PSI)

Directional
Controls

Cracking Flow

25% to 30% of Input Signal

Variation of Flow

15% @ 75% of Nominal Current


and Constant P Maintained by
Pressure Compensator

Port to Port
Leakage

10 cu. in. @ 3000 PSI

Step Response
Time at 75% of
Amps

On
Off

Cartridge Material

All parts steel. All operating


parts hardened steel.

Manual
Valves
Solenoid
Valves
Proportional
Valves
Coils &
Electronics

BC

(2)

(1)

Performance Curves
PWM Current Regulator Recommended
51L With 5 Bar, 75 PSI Compensator
51 With 15 Bar, 220 PSI Compensator and SS Coil

50 ms
40 ms

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Approx. Weight

.15 kg (.34 lbs.)

Cavity

C08-4

11.4

3.8

PULL

SP

SP

51L

.45
.90
75%

GPM LPM
6 22.8

.30
.60
50%

0
.15
.15
.30 Current .30
25% Amps 25%

.30
.60
50%

.45
.90
75%

.60
1.20
100%

Hydraulic Oil 150 SSU @ 100F (32 cSt)


PUSH 'a'

15.2

7.6

PULL 'b'

52

.60
1.20
75%

52

.40
.80
50%

.20
0
.20
.40 Current .40
25% Amps 25%

.40
.80
50%

.60
1.20
75%

.80
1.60
100%

Flow vs. Load


Compensator
P
Bar (PSI)

GPM LPM
4 15.2
11.4

7.6

3.8

5.3 - (1.4)

3.4 - (0.9)

3.4 - (0.9)

SS

SS

5 (75)

17 - (4.5)

SP

SP

15 (220)

TD

51
Standard

13.3 - (3.5)
11.4 - (3.0)

15.2 - (4.0)

SS

SS

15 (220)

52
High Flow

21 - (5.5)

17 - (4.5)

SP

SP

20 (290)

Bar

17.4 - (4.5)

13 - (3.5)

SP

SP

15 (220)

PSI

Flow

P to B, A to T

5.3 - (1.4)

Bodies &
Cavities

P to A, B to T

51L
Low Flow

10 (150)

Hydraulic Oil 150 SSU @ 100F (32 cSt)


P to A, B to T

Technical
Data

PUSH

51

51

52 With 20 Bar, 290 PSI Compensator and SP Coil

0
24V .80
12V 1.60
100%

SUPER
COIL TYPE

PULL 'b'

51L

0
24V .60
12V 1.20
100%

Typical Performance
RATED FLOW AT 75%
OF NOMINAL CURRENT
LPM - (GPM)
a
b
SOLENOID SOLENOID
PUSH
PULL

Hydraulic Oil 150 SSU @ 100F (32 cSt)

GPM LPM
5 19.0

PUSH 'a'

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

SPOOL
TYPE AND
FLOW

(4)

(1)

Fluid
Compatibility/
Viscosity

PV

CE

(3)

<6%

Operating Temp.
Range/Seals

(4)

(3)

Hysteresis @
100 Hz PWM

MV

SV

(2)

Flow

Load/Motor
Controls

FC

One piece cartridge housing ensures internal


concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
affecting performance.

Flow

Shuttle
Valves

LM

P to B, A to T

P to A, B to T
Pressure Not Compensated
Compensated With Hydrostat  P = 250 psi

PV55

P to B, A to T

70

140

210

280

350

1000

2000

3000

4000

5000

Pressure

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Directional Control Valve


Series GP02 51, 51L, 52

Catalog HY15-3502/US

Technical Information

CV

62.7
(2.47)

M.O. Option
(Unlatch and
Pull or Push)

19.8
(0.78)

27.0
(1.08)

33.8
(1.33)

94.0
(3.71)
a

FC

PC

Sample
Application Circuit
(Closed Center)

(4)

2
2(A)

(3)

4(B)

3(P)

Compensator
(R04H3)

THIRD-ANGLE
PROJECTION

DC
2

Ordering Information

MV

51

Standard

Coil
Type

Manual Override

Detented M.O.

Body
Material

Port
Size

SV

Code Coil Voltage

Code Body Material

Nitrile / Buna-N (Std.)


(SK30078N-1)

Omit Without Coil


D012 12 VDC

Omit Steel
A Aluminum

Fluorocarbon /
(SK30078V-1)

D024 24 VDC

PV
Code Port Size

Code Coil Type

Coil
Termination

Code Seals / Kit No.

51L Low Flow


52 High Flow
Code Override Option
Omit Not Required

Coil
Voltage

Omit Without Coil


SS Super Coil - 14 Watts
SP

Super Coil - 19 Watts

Code Coil Termination


Omit Without Coil
D
A

DIN Plug Face


Amp Jr. Timer*

Dual Lead Wire*

LS
H

Sealed Lead Wire*


Molded Deutsch*

Solenoid
Valves

Seals

Body Part No.

Omit Cartridge Only


4T
6T
6B

SAE-4
(B08-4-*4T)
SAE-6
(B08-4-*6T)
3/8 BSPG (B08-4-*6B)

* Add A for aluminum, omit for steel.

CE

BC

See Super Coil 1/2 I.D.


*DC Only

Bodies &
Cavities

Code Style - Closed Center


(Flow Pressure and
Performance)

Override
Option

TD
Technical
Data

Style

Manual
Valves

GP02
08 Size
Proportional
Valve

Directional
Controls

(1)

1(T)

Logic
Elements

LE

(2)

12.7
(0.50)

Proportional
Valves

53.0
(2.10)

Flow
Controls

See Super Coil


1/2" I.D.
Information For
Terminal Connectors
7/8 Hex.
30 Nm (22 lb. ft.)
Torque

LM
Load/Motor
Controls

Latching
Sleeve

39.6
(1.56)

SH
Shuttle
Valves

6.0
(.25) Stroke

Pressure
Controls

XXVDC XXW
CCX XXX H

PAT.XXXXXXX
MADEINU.S.A.

39.6
(1.56)

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

Check
Valves

Millimeters (Inches)

Coils &
Electronics

Dimensions

PV56

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Directional Control Valve


Series GP02 53, 53L, 54

Catalog HY15-3502/US

Technical Information
CV

General Description
Check
Valves

SH

4 Way, 3 Position, Proportional Directional Control


Valve. Floating Center Spool. For additional information
see Technical Tips on pages PV1-PV6.

Features

Pressure
Controls

LE
Logic
Elements

DC

Operating
Pressure

Ports 2, 3 and 4
350 Bar (5000 PSI)
Port 1
210 Bar (3000 PSI)

Directional
Controls

Cracking Flow

25% to 30% of Input Signal

Variation of Flow

15% @ 75% of Nominal Current


and Constant P Maintained by
Pressure Compensator

Port to Port
Leakage

10 cu. in. @ 3000 PSI

Step Response
Time at 75% of
Amps

On
Off

Cartridge Material

All parts steel. All operating


parts hardened steel.

Manual
Valves
Solenoid
Valves
Proportional
Valves

CE
Coils &
Electronics

BC
Bodies &
Cavities

TD

Performance Curves
PWM Current Regulator Recommended
53 and 53L With 5 Bar, 75 PSI
Compensator and SS Coil
Hydraulic Oil 150 SSU @ 100F (32 cSt)

GPM LPM
5 19.0

PUSH 'a'

50 ms
40 ms

PULL 'b'

11.4
53

53

53L

-40C to +93.3C (Nitrile)


(-40F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)
Mineral-based or synthetic with
lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Filtration

ISO Code 16/13,


SAE Class 4 or better

Approx. Weight

.15 kg (.34 lbs.)

Cavity

C08-4

RATED FLOW AT 75%


OF NOMINAL CURRENT
LPM - (GPM)
a
b
SOLENOID SOLENOID
PUSH
PULL

PUSH

PULL

SP

SP

.45
.90
75%

.30
.60
50%

0
.15
.15
.30 Current .30
25% Amps 25%

.30
.60
50%

.45
.90
75%

.60
1.20
100%

54 With 20 Bar, 290 PSI Compensator and SP Coil


GPM LPM
6 22.8

Hydraulic Oil 150 SSU @ 100F (32 cSt)


PUSH 'a'

15.2

PULL 'b'

54

54

7.6
0
24V .80
12V 1.60
100%

SUPER
COIL TYPE

53L

3.8
0
24V .60
12V 1.20
100%

Typical Performance
SPOOL
TYPE AND
FLOW

(2)

(1)

Fluid
Compatibility/
Viscosity

PV

(4)

(1)

(3)

<6%

Operating Temp.
Range/Seals

(4)

(3)

Hysteresis @
100 Hz PWM

MV

SV

(2)

Flow

Flow
Controls

PC

Specifications

Flow

Load/Motor
Controls

FC

One piece cartridge housing ensures internal


concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
affecting performance.

.60
1.20
75%

.40
.80
50%

.20
0
.20
.40 Current .40
25% Amps 25%

.40
.80
50%

.60
1.20
75%

.80
1.60
100%

Flow vs. Load


GPM LPM
4 15.2

Compensator
P
Bar (PSI)

11.4

7.6

3.8

Technical
Data

P to A, B to T

P to B, A to T

53L
Low Flow

5.3 - (1.4)

5 - (1.4)

4 - (1.0)

4 - (1.0)

SS

SS

5 (75)

53
Standard

14 - (3.8)

15 - (4.0)

SP

SP

10 (150)

9 - (2.5)

10 - (2.7)

SS

SS

5 (75)

54
High Flow

17 - (4.5)

19 - (5.0)

SP

SP

20 (290)

Bar

15 - (4.0)

15 - (4.0)

SS

SS

15 (220)

PSI

10 (150)

Hydraulic Oil 150 SSU @ 100F (32 cSt)


P to A, B to T

Flow

Shuttle
Valves

LM

P to B, A to T

P to A, B to T
Pressure Not Compensated
Compensated With Hydrostat  P = 250 psi

PV57

P to B, A to T

70

140

210

280

350

1000

2000

3000

4000

5000

Pressure

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Directional Control Valve


Series GP02 53, 53L, 54

Catalog HY15-3502/US

Technical Information

CV

62.7
(2.47)

M.O. Option
(Unlatch and
Pull or Push)

19.8
(0.78)

27.0
(1.08)

33.8
(1.33)

94.0
(3.71)
a

FC

PC

Sample
Application Circuit
(Floating Center)

(4)

3
2
2(A)

(3)

4(B)

3(P)
3

(1)

12.7
(0.50)

Compensator
(R04H3)

THIRD-ANGLE
PROJECTION

1(T)

DC
2

Ordering Information

MV

53

Standard

Coil
Type

Manual Override

Detented M.O.

Body
Material

Port
Size

SV

Code Coil Voltage

Code Body Material

Nitrile / Buna-N (Std.)


(SK30078N-1)

Omit Without Coil


D012 12 VDC

Omit Steel
A Aluminum

Fluorocarbon /
(SK30078V-1)

D024 24 VDC

PV
Code Port Size

Code Coil Type

Coil
Termination

Code Seals / Kit No.

53L Low Flow


54 High Flow
Code Override Option
Omit Not Required

Coil
Voltage

Omit Without Coil


SS Super Coil - 14 Watts
SP

Super Coil - 19 Watts

Code Coil Termination


Omit Without Coil
D
A

DIN Plug Face


Amp Jr. Timer*

Dual Lead Wire*

LS
H

Sealed Lead Wire*


Molded Deutsch*

Solenoid
Valves

Seals

Body Part No.

Omit Cartridge Only


4T
6T
6B

SAE-4
(B08-4-*4T)
SAE-6
(B08-4-*6T)
3/8 BSPG (B08-4-*6B)

* Add A for aluminum, omit for steel.

CE

BC

See Super Coil 1/2 I.D.


*DC Only

Bodies &
Cavities

Code Style - Floating Center


(Flow Pressure and
Performance)

Override
Option

TD
Technical
Data

Style

Manual
Valves

GP02
08 Size
Proportional
Valve

Directional
Controls

(2)

Logic
Elements

LE

Proportional
Valves

53.0
(2.10)

Flow
Controls

See Super Coil


1/2" I.D.
Information For
Terminal Connectors
7/8 Hex.
30 Nm (22 lb. ft.)
Torque

LM
Load/Motor
Controls

Latching
Sleeve

39.6
(1.56)

SH
Shuttle
Valves

6.0
(.25) Stroke

Pressure
Controls

XXVDC XXW
CCX XXX H

PAT.XXXXXXX
MADEINU.S.A.

39.6
(1.56)

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

Check
Valves

Millimeters (Inches)

Coils &
Electronics

Dimensions

PV58

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Catalog HY15-3502/US

Technical Information

Proportional Directional Control Valve


Series DSP105C1, C4

CV

General Description
Check
Valves

SH
Shuttle
Valves

LM
Load/Motor
Controls

FC

4 Way, 3 Position, Proportional Directional Control


Valve. Closed Center or Floating Center Spool. For
additional information see Technical Tips on pages
PV1-PV6.

Features

One piece cartridge housing ensures internal


concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
affecting performance.
All external parts zinc plated

CLOSED CENTER
(2)
(4)

Flow
Controls

(4)

(3)

(1)

(3)

PC
Pressure
Controls

FLOATING CENTER
(2)
(4)

(2)

Specifications

LE

(1)

210 Bar (3000 PSI)

Hysteresis @
100 Hz PWM

<6%

DC
Directional
Controls

Cracking Flow

25% to 30% of Input Signal

Variation of Flow

15% @ 75% of Nominal Current


and Constant P Maintained by
Pressure Compensator

Logic
Elements

Operating
Pressure

MV

(3)

(1)

Sample Application Circuit


Closed Center

Manual
Valves

Port to Port
Leakage

2
2(A)

4(B)

3(P)

1(T)

10 cu. in. @ 3000 PSI

SV
On
Off

PV

Cartridge Material

All parts steel. All operating


parts hardened steel.

Operating Temp.
Range/Seals

-45C to +93.3C (D-Ring)


(-50F to +200F)
-31.7C to +121.1C (Fluorocarbon)
(-25F to +250F)

Proportional
Valves

Solenoid
Valves

Step Response
Time at 75% of
Amps

50 ms
40 ms

Compensator
(R04H3-15.0)

1
100 PSI Check Valve
is recommended in
Tank Line
2

Floating Center

CE
Coils &
Electronics

BC

Fluid
Compatibility/
Viscostiy

Bodies &
Cavities

Filtration

Mineral-based or synthetic with


lubricating properties at viscosities
of 45 to 2000 SSU (6 to 420 cSt)

Approx. Weight

.28 kg (.57 lbs.)

Technical
Data

Cavity

C10-4

2(A)

4(B)

3(P)

1(T)

3
Compensator
(R04H3-15.0)

ISO Code 16/13,


SAE Class 4 or better

TD

PV59

1
100 PSI Check Valve
is recommended in
Tank Line
2

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Directional Control Valve


Series DSP105C1, C4

Catalog HY15-3502/US

Technical Information

CV

4.8
(.19) Stroke

3/4 Hex.
4.1 Nm
(3 lb. ft.)
Torque

66.5
(2.62)

M.O. Option
(Unlatch and
Pull or Push)

28.0
(1.10)

22.0
(0.86)

36.0
(1.43)

Latching
Sleeve

LM

118.0
(4.66)

FC

See Super Coil


5/8" I.D.
Information For
Terminal Connectors

Flow
Controls

50.0
(1.97)

1 Hex.
34 Nm (25 lb. ft.)
Torque

Pressure
Controls

PC

(4)
(3)

Logic
Elements

LE

(2)
(1)

15.9
(0.63)

Ordering Information

MV

(3)

(1)

(2)

(4)

C1

Code Override Option


Omit None
Push/Pull

(1)

Body
Material

Port
Size

SV

Code Coil Voltage

Code Body Material

Omit D-Ring / (SK10-4)


N Nitrile / (SK10-4N)

Omit Without Coil


D012 12 VDC

Omit Steel
A Aluminum

Fluorocarbon /
(SK10-4V)

Omit Without Coil


SP Super Coil - 28 Watts

PV

D024 24 VDC
Code Coil Termination

Code Coil Type


(3)

Coil
Termination

Code Seals / Kit No.

C4

Coil
Voltage

Omit Without Coil


D
A

DIN Plug Face


Amp Jr. Timer*

Dual Lead Wire*

Molded Deutsch*

Solenoid
Valves

(4)

Coil
Type

6P

3/8 NPTF (B10-4-*6P)

Proportional
Valves

(2)

Seals

6T
8T

SAE-6
SAE-8

CE

6B

3/8 BSPG (B10-4-6B)

Code Port Size Body Part No.


Omit Cartridge Only
(B10-4-*6T)
(B10-4-*8T)

* Add A for aluminum, omit for steel.


Steel body only.

See Super Coil 5/8 I.D.


*DC Only

BC
Bodies &
Cavities

Code Style

Override
Option

TD
Technical
Data

Style

Manual
Valves

DSP105
10 Size
Proportional
Valve

Directional
Controls

DC
THIRD-ANGLE
PROJECTION

Coils &
Electronics

63.0
(2.47)

SH

Load/Motor
Controls

XXVDC XXW
CAX XXX H

PAT.XXXXXXX
MADEINU.S.A.

50.0
(1.97)

Check
Valves

Millimeters (Inches)

Shuttle
Valves

Dimensions

PV60

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Proportional Directional Control Valve


Series DSP105C1, C4

Catalog HY15-3502/US

Performance Curves
CV
Check
Valves

SH

PWM Current Regulator Recommended


51 With 15 Bar, 220 PSI Compensator and SP Coil
GPM LPM
8 30.4

53 With 15 Bar, 220 PSI Compensator and SP Coil


GPM LPM
8 30.4

Hydraulic Oil 150 SSU @ 100F (32 cSt)

Hydraulic Oil 150 SSU @ 100F (32 cSt)

DSP105C4

DSP105C1

Shuttle
Valves

22.8

15.2

7.6

22.8

15.2

7.6

FC

Flow

Load/Motor
Controls

Flow

LM

Flow
Controls

0
-1.8

-1.2

-0.6

PC
Pressure
Controls

LE

0.6

1.2

1.8

-1.5

-1.0

-0.5

Current (Amps)

Logic
Elements

0.5

1.0

1.5

Current (Amps)

Pressure Compensation Pull Coil


Inlet to Work Port
GPM LPM
10 38.0

Pressure Compensation Push Coil


Inlet to Work Port
GPM LPM
8 30.4

Hydraulic Oil 150 SSU @ 100F (32 cSt)

Hydraulic Oil 150 SSU @ 100F (32 cSt)

30.4

DC

15.2

7.6

Flow

22.8

Flow

Directional
Controls

22.8

15.2

7.6

MV
Manual
Valves

SV
Solenoid
Valves

PV

Bodies &
Cavities

TD

Pressure Drop ( P)

Coils &
Electronics

BC

34

69

103

138

172

207

500

1000

1500

2000

2500

3000

Pressure (PSI)

Bar
0
PSI

34

69

103

138

172

207

500

1000

1500

2000

2500

3000

Pressure (PSI)

51 Spool Port 3 to 4

Proportional
Valves

CE

0
Bar
0
PSI

PSI
300

Bar
21

250

17

Hydraulic Oil 150 SSU @ 100F (32 cSt)

Pull
Push

200

14

150

10

100

50

Technical
Data

0
LPM
0
GPM

15

23

30

38

10

Flow (Q)

PV61

Parker Hannifin Corporation


Hydraulic Cartridge Systems

Вам также может понравиться