Вы находитесь на странице: 1из 15

Protection and control IED manager

PCM600
Communication and project setup
SA-T Training
Slide 1
1MRG003731 B

What to learn with this chapter

With this p
presentation You will learn

SA-T Training
Slide 2
1MRG003731 B

What is needed to establish the communication between the physical


IED and
d PCM600.
PCM600

How to set IP addresses for the IED objects in PCM600 and also for the
engineering PC itself running PCM600

Impact of sub networks

How to manage projects with PCM600

Creation of projects

Deletion of projects

Import/export functionality

Basic HW configuration done with the HW tool

Section 3

Section 3

Communication setup IED PC

Communication protocols

TCP/IP

IEC61850 communication connectivity


package used

SPA (only 670 series)

LON (only 670 series)

IED Ethernet ports

Front port

Galvanic

Rear port(s)

Optic

Two channels possible for 670 series

One channel only for 650 series

SA-T Training
Slide 3
1MRG003731 B

Ethernet IED Front connection

IED Front port

Default IP address 10.1.150.3

Default Subnet mask 255.255.255.0

PC port setting

IP address 10.1.150.1 up to 254

Subnet mask 255.255.255.0

650 series front port has a DHCP


server

SA-T Training
Slide 4
1MRG003731 B

Section 3

Dynamically assign IP address to the PC

Section 3

Ethernet Optic network


IP: 192.168.1.11
Mask: 255.255.0.0

IP: 192.168.1.10
Mask: 255.255.0.0

Optical cable
RX TX

IED Rear port

Default IP address 192.168.1.10

Default Subnet mask 255.255.255.0

This is an example of Class B network


addressing
dd
i conceptt

RX TX

The two first segments

Ethernet switch

The two last segments

IP: 192.168.1.13
Mask: 255.255.0.0

IP: 192.168.1.12
Mask: 255.255.0.0

Defines the Network

Define the Nodes

Rear Ethernet port NO DHCP server

Note! All devices that shall communicate


g to the same
with each other must belong
sub network

1MRG003731 B

Ethernet port settings at PC side

No settings in PCM600 for Ethernet port of PC, use WINDOWS control panel

SA-T Training
Slide 6
1MRG003731 B

Set TCP/IP properties on the connection to be used for the PCM600/IED communication

Section 3

Section 3

IED Ethernet port settings

The IP address of the IED


object in PCM600 can be set in
y ;
two ways;

When creating the IED object in


PCM600, the IP address can be
set in the Configuration
Configuration
Wizard

Opening Properties at IED


level object and changing the
IP Address property

SA-T Training
Slide 7
1MRG003731 B

Section 3

SA-T Training
Slide 8
1MRG003731 B

PCM600 project handling

Manage projects

Create the plant structure

Create the IED objects

Section 3

Manage Projects
Open/Manage projects

Create projects

Delete projects

Export projects

Import projects

All data within the PCM600


project is exported to a file with
extension .pcmp.
Used for back-up purposes.

Use earlier exported .pcmp file

Rename projects

SA-T Training
Slide 9
1MRG003731 B

Section 3

Create the Plant Structure

T
Two
ways to
t create
t objects;
bj t

Drag and drop from object types

Ri ht click
Right
li k on object,
bj t select
l t New
N

When creating IED objects, the


configuration wizard is
y started
automatically

Note:
Only one substation level is allowed

SA-T Training
Slide 10
1MRG003731 B

Section 3

Create the IED objects

Configuration modes

Online configuration

Select the protocol to use


for the PCM600/IED
communication

IED available

Offline configuration

N IED available
No
il bl

Use order files

Note: Not possible to


communicate between
PCM600 and IED via SPA
and LON for the 650 series

SA-T Training
Slide 11
1MRG003731 B

Create the IED objects, Online configuration

Set IP address to use

Different default values


f Front
for
F t and
d Rear
R
port.

SA-T Training
Slide 12
1MRG003731 B

Section 3

IED type, version, display type (Local HMI) and


housing (size of the IED) is automatically
detected in online mode (Use the Scan
Scan button)

Create the IED objects, Offline configuration

Section 3

IED version must be selected


manually

Order option file available

Enables only ordered SW and HW


in PCM600

No need to synchronize PCM600


and physical IED

No order option file available

Enables all functionality in PCM600

Need to synchronize PCM600 and


physical IED
IED, use the
License Update Tool

Possible to configure functionality in


PCM600 that later will not be
accepted by the IED

SA-T Training
Slide 13
1MRG003731 B

Section 3

Plant Structure, basics

Two main sections

IED configuration structure

SA-T Training
Slide 14
1MRG003731 B

Contains basic functionality such as


communication addresses and HW

Application configuration structure

Contains the configuration data


configured with ACT.

Synchronized with the Main Application


structure configured with ACT.

Section 3

License Update Tool

Synchronizes PCM600 IED object with


physical IED capabilities when it comes
to;

Function options

Hardware options

SA-T Training
Slide 15
1MRG003731 B

Section 3

Technical Key
( t applicable
(not
li bl ffor 670 series)
i )

SA-T Training
Slide 16
1MRG003731 B

Is used for security reasons, more


difficult to communicate with the wrong
IED since the technical key at IED
object in PCM600 and in physical IED
must match.

Unique identifier for each object in the


Plant Structure

Is set automatically by PCM600

Can be modified by the user

To synchronize PCM600 and IED


technical key, use the
Set Technical Key Tool

To change the technical key in


PCM600 only, go to object properties
for the IED object

Section 3

Set Technical Key

Technical key options

Use IED Technical key

Use PCM600 Technical key

User defined Technical key


User-defined

No special characters

Max length 13 characters

No numbers in the beginning

Note that changing the Technical key


might have an impact on the IEC61850
configuration in your system

SA-T Training
Slide 17
1MRG003731 B

Section 3

Export IED object

SA-T Training
Slide 18
1MRG003731 B

P
Purpose:

Make backup

R
Reuse
a configured
fi
d IED

Contains all configured data for the IED

A li ti C
Application
Configuration
fi
ti

Signal Matrix

Parameter Setting

Graphical Display

Communication Management (DNP)

SCL information

Hardware configuration

File extension is .pcmi

Section 3

Import IED object

Purpose:

To reuse a previously configured IED


object
bj t ((pcmii file)
fil )

Import of pcmi files can be made at the


Bay level object in PCM600
Bay

SA-T Training
Slide 19
1MRG003731 B

Section 3

Create Template

Purpose:

To reuse a configured IED

In a pre-defined
pre defined place

For quick access

Creation of template

Right click IED object

Creates a .pcmt file

Stored in PCM Databases/Templates

Contains all configured data

SA-T Training
Slide 20
1MRG003731 B

Same contents as the pcmi file

Create new IED object from Template

Purpose:

To reuse a configured IED

Initiated from the Bay level object

Section 3

New->Create from Template

Templates structured based on IED


type

SA-T Training
Slide 21
1MRG003731 B

Section 3

IEC 61850 configuration SCD

SCD file

Contains

Substations Configuration Description

SCL information for all IEDs within the


substation

Export/Import of SCD file

Done at Substation level

SCL engineering done outside


PCM600 export/import functionality
PCM600,
needed.

Note! When importing SCL files to PCM600, be sure to import an SCL


file that correlates with the PCM600 project or you might loose data
SA-T Training
Slide 22
1MRG003731 B

Section 3

IEC 61850 configuration ICD

ICD file

IED Capability Description

Contents

All thats configured in the IED before


the system configuration

No SA Section

N C
No
Communication
i i section
i

IEDName = TEMPLATE

U
Usage

System engineering

Merging to an SCD file

Export/Import of ICD file

At IED level

SA-T Training
Slide 23
1MRG003731 B

Section 3

IEC 61850 configuration CID

CID file

Contents

Extract of the SCD file

SCL information for one specific IED

Export/Import of ICD file

SA-T Training
Slide 24
1MRG003731 B

Configured IED Description

At IED level

Section 3

Report Parameters

Footer information for printouts

Application configuration

Local display, Graphical display editor

Parameter settings

Communication management

SA-T Training
Slide 25
1MRG003731 B

Hardware Configuration

Possible to manually configure HW/slot positions

SA-T Training
Slide 26
1MRG003731 B

This information is already available if you have


created the IED object in online mode

Select correct card type in correct slot position

Section 3

Section 3

Hardware Configuration

Compare configuration

Reads hardware configuration from the


IED and compares with the HW
configuration made in PCM600

Before you do any other configuration


e g with ACT or SMT
e.g.

Make sure that the HW configuration


matches with your physical IED

If not,
you might need to spend time for
reconfigure of your IED.

SA-T Training
Slide 27
1MRG003731 B

Hardware Configuration, parameterization

SA-T Training
Slide 28
1MRG003731 B

Section 3

Parameter Setting

Short-cut to parameters/settings for


th HW when
the
h HW ttooll iis open

Select HW module from hardware


g
list
configuration

Press Parameter Setting button in


toolbar menu and that will issue the
PST

Only change of parameters possible


when opening PST from the HW
tool.

Read/Write with the IED is done from


ordinary PST.
(e.g. open PST from the Plant
Structure).

Time for exercise!


E
Exercise
i 1
1, C
Create
t a project
j t

Section 3

SA-T Training
Slide 29
1MRG003731 B

Section 3

SA-T Training
Slide 30
1MRG003731 B

Вам также может понравиться