Вы находитесь на странице: 1из 9

Operators Manual

XK315A1W Series Wireless Weighing Indicators


Applications: Electronic platform scale, weighing scale, etc.

1. Introduction
Wireless Communication Frequency
Wireless Communication Distance
Wireless Communication Rate
Display

Division
Serial Interface

Connect by RS232
Weight Unit
Decimal System/Hexadecimal System
External AC Adapter
Rechargeable Internal Battery
Operating Temperature
Storage Temperature
Relative Humidity
Dimensions

Weight
Version

430 MHz
30M/1500M (optional)
9600bps
XK315A1W: 6-digit 0.8 inches red LED
XK315A1GB-W: 6-digit 0.8 inches green LED
XK315A1GB-5-W: 6-digit 0.8 inches green LED
1/2/5/10/20/50/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005
RS232 interface with continuous data output
Baud rate 1200, 2400, 4800, 9600
Optional RS485 interface
Display, computer, printer, etc.
kg/lb/UU (user unit should be set in factory)
lb and UU can be in two systems
100-240VAC 50/60Hz
6V/4AH
10 C to +40 C
25 C to +55 C
10% to 85% non-condensing
XK315A1W: 220140130 (mm)
XK315A1GB-W: 260222161 (mm)
XK315A1GB-5-W: 26516258 (mm)
2kg
VER 22.0

2. Wireless Connection
Note: One wireless indicator only can connect with one wireless weighing transmitter, and both
wireless communication frequencies should be same. Wireless communication frequencies are set in
factory and user cannot change. Regular wireless communication frequency is 430MHz
If user wants to use two or more than two set of wireless weighing indicator and wireless weighing
transmitter, wireless communication frequencies must be different. Please let salesman know and
wireless communication frequencies will be set in factory.
1. Connect wireless weighing transmitter with load cell.
2. Switch on wireless weighing transmitter until the wireless function works.
3. Switch on wireless weighing indicator and calibrate.
4. In configuration mode, set Con to Con=78.
5. When indicator wireless lamp flashes, wireless weighing transmitter and wireless weighing indicator
are connecting.
6. Then, to calibrate wireless weighing indicator and configure.
7. RS-232C D-B 9: Pin 3 Output (TXD) and Pin 5 Signal Ground (GND)

8.

RS232 interface is continuous data output

9. Address = 0continuous data output, form is =,X1,X2,X3,X4,X5,X6, while X1,X2,X3,X4,X5,X6 is


data,= is break. E.g.: if weigh is 123.45kg, data will be = 54.321 =54.321
Address = 99continuous data output, form is =,X6,X5,X4,X3,X2,X1, while X6,X5,X4,X3,X2,X1 is

data,= is break. E.g.: if weigh 123.45kg, data will be = 123.45= 123.45

3. Keypad Function and Status Indicators


ON: Switch on XK315A1W
OFF: Switch off XK315A1W
: Manual accumulation mode
*: Select function and configure
: Move flashing digit
: Increase flashing digit and high resolution
0: Zero, tare and decrease flashing digit
AC: Mains power applied

: Battery capacity

AUT: Automatic accumulation mode


T: Tare mode
lb: lb mode
wireless: Wireless connected

: Weight stable
0: Zero mode
UU: User weighing unit mode

4. Configuration
1. Correct connect load cell wireless weighing transmitter wireless weighing indicator
2. Configure as follow step
3. Press * to configure and next step
Step
1

Operation

Displaying

Press 0 000000
On
999999

Descriptions
In switch off states, press 0 key and ON to switch on
indicator. Segment checks, and displays [UE-22.0] to configure and
calibrate

Press *
Press *

CAL SP Indicator in calibration mode


-SEt- Indicator in configuration mode

Press

Select division

Press
Or 0

0.001-0.002-0.005-10-20-50-100-200-500-0.10-0.20-0.50-1-2
-5-0.1-0.2-0.5-0.01-0.02-0.05
Factory default d = 0.01

Press *
Press
Press

6000
000000
001000

015000

Set full scale


Press to move digit
Press to increase digit
Press 0 to decrease digit
Factory default FS = 150.00

Press *
Press
Press
Or 0

FLt 1

Filter range: 0 ~ 2
0-fastest 2-slowest
Digit flashes
Factory default Filter = 2

Press *
Press
Press
Or 0

AUtP00

Ones digit means automatic switch off function:


Ones digit0,2,4 means automatic switch off function enable
Ones digit1,3,5 means automatic switch off function disable
Tens digit means range of zero track (0~9):
0:0.4d 1:0.4d 2:0.8d 3:1.2d 4:1.6d 5:2.0d
6:2.4d 7:2.8d 8:3.2d 9:3.6d
Tens digit also means range of zero:
Tens digit0 means no zero set at start operation
Tens digit1:
2

Ones digit =0 means zero when weight is 2FS,


switch off function disable
Ones digit=1 means zero when weight is 2FS,
switch off function enable
Ones digit=2 means zero when weight is 20FS,
switch off function disable
Ones digit=3 means zero when weight is 20FS,
switch off function enable
Ones digit=4 means zero when weight is 50FS,
switch off function disable
Ones digit=5 means zero when weight is 50FS,
switch off function enable
Tens digit flashes.
Factory default AUtP = 11
7

Press *
Press
Press
Or 0

Adr 00

Select address:
Continuous data output , Adr=00 or Adr=99
Communicate is by modbus between 01-95
Factory default Address = 00

Press *
Press
Or 0

b 2400
b 4800

Select baud rate:


1200240048009600
Factory default baud rate = 2400

Press *

Confirm configuration

and automatic
and automatic
and automatic
and automatic
and automatic
and automatic

5. Wireless Communicate
After above configuration, set the wireless communicate
Step

Operation

Displaying

Descriptions

Press
Press
Press
Press
Press

*
*
*
*
*

CAL SP
-SEt-
-A-d-
FACT
Con

Indicator in calibration mode


Indicator in configuration mode
Enter ADC counts display
Back to factory set
Set wireless communicate address

Press

Con 78

Enter address which is same as wireless weighing transmitter

Press *

Back to weight states

Press *

ConSEA

Search wireless communicate address automatically

Press

Con xx
Con-78

Search wireless weighing transmitter


When indicator searched wireless weighing transmitter, it will display
the address (go to step 6 or step 7)

Press

2300

Follow step 5, save the address and return to weighing mode

Press *

2300

Follow step 5, delete the address and return to weighing mode

2300

6. Calibrate
After above setting, calibrate indicator directly:
Step

Operation

Displaying

Descriptions

Press *
Press

CAL SP
CAL 00

Indicator in calibration mode


Enter to set ZERO

Press *

------
3000

Set ZERO
After several seconds, indicator displays maximum weight

Load max weight


Press *

Display weight

Press
Press
Or 0

000000

Press *

------
2000

3000

002000

If the weight is not the max weight, press and or


0 to input actually weight
e.g.: weight is 2000
Calibrate
After several seconds, indicator displays weight, then finish
calibrate

7. ADC Counts Display


Confirm load cell connect is correct to check ADC counts. After set the short pin, ADC counts should around
100000-200000. After above setting, check ADC counts directly:
Step

Operation

Displaying

Press *

CAL SP

Press *

-SEt-

Indicator in configuration mode

Press *

-A -d-

ADC counts display

Press

43125

Enter to check ADC counts, and display 43125

Press *

Return to weighing mode

Descriptions
Indicator in calibration mode

8. Factory Set
Step

Operation

Displaying

Press *

CAL SP

Press *

-SEt-

Indicator in configuration mode

Press *

-A -d-

Indicator in ADC counts display mode

Press *

FACt

Press

Descriptions
Indicator in calibration mode

Select Back to factory set


Back to factory set and return to weighing mode

Factory default: d=0.01FS=150.00FLt=2AUtP=11Adr=00b=2400

9. Weighing Unit
Step

Operation

Displaying

Press *
On

000000
999999

Press * and ON to switch on indicator


If it displays [UE=21.X], user can set own unit

Press

2.0000

Select unit

Press

000000

Digit flash

Press
0

01.6535

Change digit number


If user unit is Hong Kong kg, enter 1.6535

Press *

HE

Decimal/Hexadecimal(lb And UU)


0---Decimal
1---Hexadecimal
Hexadecimal displays automatically retain two decimal points. 2

Descriptions

After The Decimal Point Every 16 Binary


6

Press

HE

Digit flash

Press
0

HE

Change digit

Press *

d 0. 0.0

Set display form when unit is lb or UU


HE=1, d has two situations: 0. 0.0 and 0. 0

Press
0

d 0. 0

Change situation

10

Press *

Save setting and return to weighing mode

10. Operation
1. ON/OFF Press ON switch on indicator; and press OFF to switch off indicator.
2. ZERO Press 0 for more than two seconds when Weight is 2F.S, weight is ZERO and
0 will be displayed

3.

TARE

a. Weight tare When T turns off and weight is 0 stable, press 0 to display Zero and
T turns on
b. Remove tare When T turns on, press 0 to clear tare and T turn off
c. Number tare Press to set tare. Press to enter tare (unit is kg), and press 0
to save tare and T turns on
d. Accumulation
In manual accumulation mode, weight is 20d stable, press to accumulate
weight and display accumulation times, e.g.: n 12

Note: one weighing result only can accumulate one time, next accumulation weight must after weight
20d.
4. High resolution In weighing mode, press to display the weight in X10 resolution and last
decimal point turns on. Press again to show regular weighing resolution.
Note: In lb and UU mode, indicator has no high resolution function.
5. Display accumulation (in weighing mode)
Step

Operation

Displaying

Descriptions

Press *

12

Display accumulation times

Press

23

Display upper 4 digits of accumulated weight, e.g.: 23

Press

L506.5

Display upper 4 digits of accumulated weight, e.g.: 506.5


So, the accumulated weight is 23506.5

Accumulated is Decimal even weight is Hexadecimal.


6. Select weighing mode (in weighing mode)
Step

Operation

Displaying

Press *

Press *

Aut 0

12

Descriptions
Display accumulation times
Select manual/automatically accumulation
Aut=0: regular weighing mode and manual accumulation
Aut=1: regular weighing modeautomatically accumulation after
stable, and -AUT- turns on
Aut=2: regular weighing modesave weight automatically after
stable, accumulate finial weight which is unload 20d, -AUT-
turns on
Aut=3: animal weighing mode, accumulate automatically finial

weight which is unload 20d, -AUT- turns on


Aut=4: peak hold mode, accumulate automatically finial weight
which is unload 20d, -AUT- turns on
Aut=5: animal weighing mode and manual accumulation
Aut=6: peak hold mode and manual accumulation
Aut=7: counting mode and manual accumulation
Aut=8: double-way weighing mode, weight pressure and pull from
positive and negative way
Aut=9: Minus weighing mode
3

Press
Press
Or 0

Aut 0

Change mode

Press *

Lock time of animal function when Aut=3 or this step display on


Aut=3. Otherwise , return to weighing mode
t=0-9 second, and weighted is average during lock time.

Press
Or 0

Change lock time

Press *

Return to weighing mode

7. Clear accumulation
Press * to display accumulation data and press 0 to clear
accumulation data.
8. Enter number Press to move flashing digit, press to increase flashing digit and press
0 to decrease flashing digit.
9. Rechargeable internal battery Switch on indicator and display Pbt 85 means battery capacity is
85%
10. Remind charge battery

When battery capacity is 30%,

turns on to remind user charge

battery. When battery capacity is 10%, display flashes to remind user charge battery immediately.
11. Over-discharge protection
When battery capacity is 0%, indicator will switch off automatically to
protect battery.
12. Save power mode In switch off automatically mode, display to save power after three
minutes no operation.
13. Switch off automatically In switch off automatically mode, indicator will switch off after 30 minutes
no operation.
14. Full charge battery operation
Indicator can work 30 hours continually.
15. kglbUU
Press * more than 2 second to change weighing unit. The change order is
kglbUUkg.
16. When wireless weighing transmitter battery capacity is 10%, up digit displays b, e.g.: b 3.00

11. Counting Mode (AUT=7)


1. Sample data Put samples on scale when net weight is zero (TARE when net weight is not zero).
Sample amount should between from 1 to 999, and more samples, weight will be more accurate.
Step

Operation

Displaying

Load samples

press

Cnt000

Enter sample amount

press

Cnt030

Enter sample amount 30

27

Descriptions
Display weighing of samples

press
or 0
4

press *

30

Save samples data and display samples amount

press

27

Press to change weighing and amount displaying

2. Operation put the weight on scale, number is weight when indicator displays
54, and number
is amount when indicator displays C 60. Press to change weight and amount displaying. After
the sample weight is stable, press to displays accumulate weight and amount.
3. Display and clear accumulated data
Step

Operation

Displaying

Descriptions

47 Indicator in counting mode


8 Display number of samples

Press *

Press

C 532 Display accumulation number

Press *

47 Return to counting mode

Press

42 Change to display weighing mode

Press *

8 Display number of samples

Press

0 Display upper 4 digits of accumulated weight

Press

L 471 Display lower 4 digits of accumulated weight

Press *

Press *

10

Press 0 C

42 Return to weighing mode


8 Display number of samples
47 Delete accumulation weightand return to counting mode

When indicator displays accumulation times, press 0 to delete accumulation weight.

12. Double-Way Weighing Mode (AUT=8)


1. Indicator can receive positive and negative signal.
2. When the weight signal is positive, indicator displays positive weight number and it can be TARE
When the weight signal is negative, indicator displays negative weight number and it cannot be Tare
3. In double-way weighing mode, indicator hasnt Accumulation and printer function.

13. Minus Weighing Mode (AUT=9)


1. Indictor displays moved weight
2. Operation: put the weighing on scale and press 0 for long time to zero. If move the weigh,
indicator will display moved weigh. (the number is positive)
3. In minus weighing mode, indicator has TARE, Accumulation and printer functions.

14. Printer format


Indicator connect printer by serial interface: Adr=01-95: press to output print signal in accumulation
mode.
Print form:
O: 0002
G: 7.73kg
T: 4.82kg
N: 2.91kg
Counting mode
NO: 0002
G: 7.73kg
T: 4.82kg
N: 2.91kg

C: 54pcs
Accumulation mode
NO: 0002
S: 5.82kg
Accumulation with counting mode:

NO: 0002
C: 108pcs
S: 5.82kg

15. Safety precautions


1. Do not expose indicators to either direct sun light or any heat sources.
2. Do not use indicators in hazardous area or in dusty environments.
3. Weight cannot more than max weighing
4. Do not use strong solvents (such as: benzene, nitric acid oil) to clean the indicators.
5. Never flood the Indicator, immerse it in liquid or pour liquids on it.
6. Do not open the indicator! The warranty is void if this stipulation is ignored. The indicator may only be
opened by authorized persons.
7. Battery is recharged when AC power connects.
8. Use short pin to test indicator: if indicator doesnt displays weight number, please switch off it, take off
load cell connector and take on short pin. Switch on indicator, after displays 0-9 self-test patterns. See
following two situations:
a. Indicator displaying one number means indicator works well.
b. Indicator displaying many mass numbers means indicator needs repair.

16. Services
The Warranty time is in one year after sale date of non-human failure. Indicator is lifelong service.
(NOTE: Battery is not under warranty)

17. LED Error Code


Code

Meaning

OUEr

Weight > FS + 9d

OUEr

Weight -20d or 100%FS (in double-way weighing mode)

Weight number flashing


bxxxxx

30% battery warning to recharge the battery


10% battery warning to recharge the battery
Wireless weighing transmitter 10% battery warning to recharge the battery