PLUMBING REVIEWER
What ancient roman term refers to an individual who worked in
the sanitary field of ancient Rome?
What is the title given to a person who is a skilled worker in the
field of sanitation?
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
PLUMBARIUS
PLUMBER
NATIONAL PLUMBING
CODE OF THE PHILS.
IRA 1378
BIOCHEMICAL OXYGEN
DEMAND
27
28
29
30
31
1/20
28-Jun-55
17th CENTURY
ACT 2152
FALSE
TRUE
LEAD a metal used by
Romans as a plumbing
material
SOIL PIPE
WASTE PIPE
GRAVITATIONAL FLOW
METHOD
DISTRIBUTION BY MEANS
OF PUMP
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
PLUMBING REVIEWER
In dual main systems, ____________ are added on the south and
west sides of streets and piping is generally placed beneath
sidewalks.
____________, sometimes called arterial mains, for in the
skeleton of the distribution system.
____________ is used for city water pipes.
____________ is used for pipelines, truck mains and inverted
siphon where pressures are high and sizes are large.
____________ a stronger and more elastic type of cast iron used in
newer plumbing installation.
A chemical reaction which involves the removal of metallic
electrons from metals and formation of more stable compounds.
Consist of a cylinder in which a piston or a plunger moves
backwards and forwards.
Used to raise water from shallow depths and used most frequently
for individual houses.
____________ is a pump that increases the pressure within the
distribution system or raise water to an elevated water storage tank.
Pump that lifts surface water and move it to a nearby treatment
plant.
Pump that discharge treated water into arterial mains.
Used to supply or remove water from a building.
Centrifugal casting on metal moulds is sometimes called
____________ .
Necessitates a large pipe or conduit so that velocities will be low
but not low enough to allow sedimentation.
Generally, the equalizing volume of a water thank that is about
____________ of the total daily demand.
In residential areas having houses up to 4 storeys high, the
pressure in the pipes should be between _____________.
High service system is high lying areas; while _____________ is to
low lying areas
TRUE OR FALSE : Water distribution is a network of pumps,
pipelines, storage tanks and appurtenances.
It is a special type of underground water that is found on islands
or in the coastal regions near the sea.
This should be supplied with water in sufficient volume or at
adequate pressure to enable them to function properly.
Flush tanks which are directly connected to the potable water
supply system should be equipped with approved ___________.
_____________ is a junction between water supply systems
through which water from doubtful or unsafe sources may enter an
otherwise safe supply.
What are the 3 main sources of water supply?
55
56
58
59
60
61
62
63
PRIMARY FEEDERS
CAST IRON PIPES
STEEL PIPES
DUCTILE IRON
CORROSION
RECIPROCATING PUMP
HAND PUMP
BOOSTER PUMP
LOW LIFT PUMP
HIGH LIFT PUMP
PIPE LINES
DELAVAUD PROCESS
INTAKE CONDUIT
1/6 to 1/3
1.8 x 105 to 2.8 x 105 N/m2
LOW-SERVICE SYSTEM
TRUE
FRESH WATER
PLUMBING FIXTURES
BALL COCKS
CROSS CONNECTION
* RAINWATER
* GROUNDWATER
* SURFACE WATER
54
57
SERVICE HEADERS
WATER METER
VACUUM BREAKER or
BACKFLOW PREVENTER
2/20
BACKFLOW
TURBIDITY
COLOR
ALKALINITY
IRON
OPEN TRENCH WORK
COEFFICIENT OF LINEAR
EXPANSION
64
PLUMBING REVIEWER
________________ is water bearing stratum.
65
66
67
68
69
70
71
72
73
79
80
75
76
77
78
94
95
96
81
82
83
84
85
86
87
88
89
90
91
92
93
97
98
99
SANITARY DRAIN
SOIL PIPE
WASTE PIPE
POTABLE WATER
WATERBOURNE
DISEASES
TURBID
MAXIMUM CONTAMINANT
LEVELS
MCL means
A type of house drain that receives discharges of sanitary as well
as storm water.
This type of drain is now considered obsolete and not advisable.
In large buildings, _____________ are usually suspended from the
basement ceiling.
A cleanout shall be provided on the house drain as near as
possible the ______________ of the building.
A kind of drain that should terminate into a separate drainage
system.
The house drain should be provided with adequate number of
74
AQUIFER
WATER TABLE WELL &
ARTESIAN WELL
2%
3/20
COMBINED DRAIN
COMBINED DRAIN
HOUSE DRAIN
FOUNDATION WALL
INDUSTRIAL DRAIN
CLEANOUTS
PD 856
200m
TRUE
FALSE
FALSE
PRIVY
CATCH BASIN
CESSPOOL or DRYWELL
GOVERNMENT
SEWAGE
INFLOW
ACID VENT
SEPTIC TANK
SEWAGE PUMP
ANAEROBIC BACTERIA
COMBINATION PUBLIC
SEWER
0.90m
HOUSE SEWER
HOUSE DRAIN
2.8 - 3.0 TIMES
PLUMBING REVIEWER
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
120
121
122
123
124
125
50%
TRUE
TRUE
TRUE
FIXTURE DRAIN
WATER
ABSORPTION
INSIDE STORM DRAIN
STORM DRAIN
ROOF LEADER
OUTSIDE STORM DRAIN
OVERHEAD STORM
DRAIN
119
RA 9003
What do you call the drain from the trap of a fixture to the
junction of the drain pipe?
All storm drains should be graded at least
This type of terminal should be used only where the public sewer
discharges its contents into a terminal other than a disposal plant.
The roof leader is extended _________ through the floors of the
building to a point just below the roof & is then extended _________
to reduce the danger of breakage which may result because of
expansion and contraction of the roof.
Conductor is to vertical; __________ is to horizontal
Catch basin is a receptacle in which _________ are retained for a sufficient
period of time to allow settle able material to deposit
TRUE OR FALSE : The discharge capacity of the pipe varies
according to its length and grade per foot.
FIXTURE DRAIN
INCH PER FOOT
COMBINATION HOUSE
SEWER
VERTICALLY,
HORIZONTALLY
GUTTER
LIQUID
TRUE
126
TRUE OR FALSE : One factor which makes the sizing of storm drain
difficult is the matter of grouping rainfall over a given period.
TRUE
127
FALSE
4/20
TRUE
TRUE
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
PLUMBING REVIEWER
TRUE OR FALSE : The base of the roof leader must be provided
with a concrete or stone foundation.
TRUE OR FALSE : If the roof leader is constructed of galvanized
steel, it must be supported at every floor with a pipe rest.
TRUE OR FALSE : Horizontal runs may not be suspended from
band iron hangers or steel ring hangers anchored in the structure
TRUE OR FALSE : The roof leader is extended vertically through
the floors of the building to a point just below the roof and is then
extended horizontally to reduce the danger of breakage which may
result because of expansion and contraction of the roof.
TRUE OR FALSE : A cast-iron strainer basket is attached to the
drain to prevent stones, leaves and other materials from entering the
conductor.
TRUE OR FALSE : Roof drains are provided with a copper flashing,
or in some instances, with a cast-iron clamp so that the joint
between the roof and the conductor will be water-tight.
TRUE OR FALSE : A roof leader may be terminated by placing a
hub of cast-iron soil pipe flush with the roof.
Do appurtenances need direct connection to water supply?
What type of plumbing material is a water heater?
What do you call a faucet opened or closed by the fall or rise of a
ball floating on the surface of water?
What is the most expensive type of all pipes?
What type of pipe is durable and has extreme resistance to
corrosion?
What type of plumbing material is a water closet?
What type of pipe is the most specified material need for drainage
installation in buildings?
What plumbing material receives water-bourn wastes?
What type of plumbing material is a soap dispenser?
151
152
153
154
155
156
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
NO
APPLIANCE
BALL COCK
BRASS PIPE
COPPER PIPE
FIXTURE
CAST IRON PIPES
FIXTURES
APPURTENANCE
CAST IRON SOIL PIPE
INSTITUTE
UNPLASTICIZED
LESS THAN 25-STORIES
ASBESTOS-CEMENT NONPRESSURE SEWER PIPE
TRUE
SILICON
CLAMP GATE CALVE
FLUSHOMETER VALVE
VITRIFIED CLAY PIPE
DRUM TRAP
Cesspool
Drain
157 The lowest portion of the inside of any pipe or condult that is not vertical
Invert
Privy
5/20
Sludge
Vent Pipe
Sewer Pipe
2%
PLUMBING REVIEWER
163 All Changes in direction shall be made by the appropriate use of 45 deg.
164
165
166
167
Bends
Crown weir
Coupling
artesian well
lavatory faucet
168 One of the first steps in the selection of a suitable water supply source is:
water (potability)
2dia
coagulant
schedule
elbow
6/20
Turnbackle
Globe valve
catch basin
dip
drain pipe
effluent
soil stack
standpipe
septic tank
sludge
water hammer
PLUMBING REVIEWER
205 a flange used on a pipe to cover a hole
206 end of a pipe that fits into a bell
207 backflow due to negative pressure
208
What do you call a vertical pipe installed primarily for the purpose of
providing circulation of air to and from any part of the drainage system?
209 gas, fume or vapor used for the destruction or control of insects
210 vertical pipes which receive discharge from water closets
escutcheon
spigot
back siphonage
vent stack
fumigant
soil stack
check valve
cistern
flush valve
7/20
caulking
disinfections
90 cms.
1.50 mts.
70 cms.
1.80 mts.
1.50 cum
508 mm.
1.50 mts.
15.20 mts.
45.70 mts.
30.50 mts.
51 mm.
102 mm.
60 cms.
38 mm.
51 mm
Polyethylene
Corporation Stop
Relief Vent
Escutcheon
Developed Length
Flush Valve
Sewage
Carbon Monoxide
Storm Sewer
1 1/2'
1/8 Bend
1-1/2"
3/8"
Battery of Fixtures
Common Vent
4"
4"
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
PLUMBING REVIEWER
Minimum height of a branch vent above the fixture it is
venting.
It refers to an individual who worked in the sanitary
field of ancient Rome.
In Latin, it means 'lead'.
A specially designed system of waste piping
embodying the horizontal wet venting of one or more
sinks or floor drains by means of a common waste and
vent pipe adequately sized to provide free movement of
air above the flow line of the drain.
Sanitary sewage from buildings shall be discharged
directly to the nearest ___.
Receptacles intended to receive and discharge water,
water-carried waste into a drainage
system with which they are connected.
Standard size of an outlet for a dry standpipe located
at each floor.
A vent pipe connected to a vent stack.
A vent pipe connected to a stack vent.
Instrument used for measuring atmospheric pressure.
Best type of fire detection that can detect fire during
the incipient stage.
A faucet fitted with a nozzle curving downward used
as a draw-off tap.
Reference in measuring the depth of a trap seal of a
trap.
A pipe fitting shaped like 'S'.
Minimum size of trap and waste branch for a shower
stall.
Minimum size of trap and waste branch for a pedestal
urinal.
Minimum head of water, in meters, required for each
section of plumbing for water test.
How many days, at least, shall be given before any
plumbing work inspection is done after written notice for
inspection.
Minimum time, in minutes, required for water to stay in
the system or pipes for a water test without any leaks to satisfy
said testing.
Minimum lead content in percent for pipes and fittings
safe for humans.
Minimum vertical distance from the bottom of water pipes
to the top of sewer or drain pipe if laid in the same trench on
top of the other.
Minimum distance of water pipings from any regulating
equipment, water heater, conditioning tanks, and similar
equipment requiring union fittings.
Maximum spacing of pipe supports at intervals.
Equivalent of 1/6 bend in degrees.
Minimum clearance in front of any cleanout in meters for
pipes 51mm or less in diameter.
Minimum clearance in front of any cleanout in meters for
pipes larger than 51 mm. Dia.
Maximum distance of any underfloor cleanout from any
access door, crawl space, or crawl hole.
Maximum length of a tailpiece.
Minimum length of any branch requiring separate venting.
Minimum extension of a vent stack through roof above the
roof
Minimum extension of a vent stack through roof above
any other vertical surface.
Minimum vertical distance of VSTR from above of any
openable window or opening.
Minimum vertical extension of VSTR from any roofdeck
where it is protruded.
8/20
6"
Plumbarius
Plumbum
Combination Waste and
Vent system
15 minutes
8%
300 mm
300 mm
4 ft.
60
305 mm
450 mm
6.10 mts.
600 mm
4.60 mts.
15 cms.
300 mm
0.90 mtr.
2.10 mts.
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
PLUMBING REVIEWER
Minimum horizontal distance of any VSTR from a
roofdeck used for other purposes aside from protection from
weather.
Minimum number of stories served by a waste stack
requiring a parallel ventstack.
An automatic device used for converting high, fluctuating
inlet water pressure to a lower constant pressure.
The process of removing calcium and magnesium deposits
in water.
Women's urinal fixture.
A type of water closet that is least efficient, subject to
clogging, noisy, and use a simple washout action through a
small irregular passageway.
This type of water closet is similar to that of the siphon-jet
except that it has a smaller trap passageway and smaller water
surface area, moderately noisy.
A type of water closet that is noisy but highly efficient.
Strong jet into up leg forces contents out. Use only with flush
valve, requires higher pressure.
Water closet that is quiet, extremely sanitary, water is
directed through the rim. It scours bowl, folds over into jet;
siphon.
A water closet that is sanitary, efficient, and very quiet.
Water enters through the rim and through the down leg.
A toilet bowl similar to the siphon-jet, but having the
flushing water directed to the rim to create circular motion or
vortex which scours the bowl.
A toilet bowl in which the flushing water enters through
the rim and a siphonic action initiated by a water jet draws the
contents of the bowl through the trapway.
A water closet similar to that of the siphon jet but with a
smaller water surface and trapway.
This type of water closet is prohibited by some health
codes
The concussion and banging noise that results when a
volume of water moving in a pipe suddenly stops or loses
momentum.
A shutoff valve closed by lowering a wedge-shaped gate
across the passage.
A valve closed by a disk seating on an opening in an
internal wall.
Liquid sewage that has been treated in a septic tank or
sewage treatment plant.
The centerline of pipe.
The interior top surface of a pipe.
The interior bottom surface of a pipe.
Color code for pipes containing acid.
One of the earlier plastic to be developed in 1938, a du
pont trade name for the white, soft, waxy, and non-adhesive
polymer of tetrafluoroethylene.
a. Cleanouts may be omitted on a horizontal drain less than 1.5
meters in length unless such line is serving sinks or urinals.
b. no galvanized wrought iron or galvanized steel pipe shall be
used underground and shall be kept at least 15 cms above
ground.
c. 1 3/4" diameter is 'not' a commercial size of G.I. Pipe for
water supply.
a. number of fixture unit is one parameter in sizing a drainage
pipe.
b. brass and cast iron body cleanouts shall not be used as a
reducer or adapter.
c. 60 branches or offsets may be used only when installed in a
true vertical position.
Collection line of a plumbing system is sometimes
referred to as.
9/20
3.00 mts.
10
Pressure Regulating Valve
Softening
Washdown
Washdown
Reverse Trap
Blowout
Siphon Vortex
Siphon Jet
Siphon Vortex
Siphon Jet
Reverse Trap
Washdown
Water Hammer
Gate Valve
Globe Valve
Effluent
Spring Line
Crown
Invert
black
Teflon
all true
all true
House Drain
307
308
309
310
311
312
313
314
PLUMBING REVIEWER
Single lever valves used in kitchen sink and lavatory
faucets or at shower valves works by the principle of a ___.
Treats hard water.
What combination of pipe fittings is installed at the base
of a soil stack?
The first section of water supply piping in a building after the
water meter.
A bathroom containing a water closet, a lavatory, and a bathtub.
A valve in which the flow of water is cut off by means of a
circular disk that fits against the valve seat. The plane of movement
of the disk is parallel to the normal direction of flow of water, which
is turned through a tortuous passage to direct the flow normal to the
face of the disk.
A receptacle attached to a plumbing system other than a trap in
which water or wastes may be collected or obtained for ultimate
into the plumbing system.
Any group of two or more similar adjacent fixtures which
discharge into a common horizontal waste or soil branch.
322
323
Ball Valve
Zeolite
Wye and 1/8 Bend
Water distributing pipe
Full bath
Globe valve
fixture
Battery of fixtures
Drainage, waste and vent
point of disposal.
A valve in which the flow of liquid is controlled by a rotating
324 drilled ball that fits tightly against a resilient (flexible) seat in the
valve body.
A vertical length of soil or waste stack at least 8 feet in height (a
325 storey high), within which the horizontal branches from one storey or
floor of the building or structure are connected to the stack.
A pipe connecting upward from a soil or waste stack below the
floor and below the horizontal connection to an adjacent vent stack
326
at a point above the floor and higher than the highest spill level of
fixtures for preventing pressure changes in the stack.
A kind of return bend of small-sized faucet, one end of which is
Gooseneck
Privy
Riser
Stack
Water main
cesspool
plumbing
Building sewer
Ball valve
Branch interval
Yoke vent
about one foot long and the other end is about three inches. It is
327 commonly used as a faucet for pantry sink and drinking fountain. Also
gooseneck
the lead connection between the service pipe and the water main.
Also a p-trap.
A watertight receptacle which the discharge of sanitary plumbing
system or part thereof, designed and constructed to retain solids,
328 digest organic matter through a period of detention and to allow the
Septic tank
liquids to discharge into the soil outside of the tank through a system
of open jointed subsurface piping or seepage pit.
A common measure of the probable discharge into the drainage
system by various types of plumbing fixtures on the basis of one unit
329
of this being equal to a discarge rate of 7.5 gallons per minute or
one cubic foot of water per minute.
10/20
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
PLUMBING REVIEWER
The installation of parts of the plumbing system which can be
completed prior to installation of fixtures or finishing. This includes
drainage, water supply and vent piping and necessary fixture
supports.
A fitting or device designed and constructed to provide, when
properly vented, a liquid seal which prevents backflow and passage
of foul air and gases without materially affecting the flow of sewage
or wastewater through it.
A suction created by the flow of liquids in pipe, a pressure less
than the atmospheric pressure.
A vertical pipe which conveys only wastewater or liquid waste
free of fecal matter.
A pipe which conveys potable water from the building supply
pipe to the plumbing fixtures and other outlets.
Any pipe which conveys the discharge of water closet, urinal or
fixtures having similar function, with or without the discharges from
other fixtures to the building drain or building sewer
In a building consists of the water service pipe, water supply
line, water distributing pipes and the essential branch pipes, valves
and all other appurtenances for the supply of potable water.
A vent connecting one or more individual vents with a vent stack or stack
vent
A branch vent that serves two or more traps and extends from in front of
the last fixture connection of a horizontal branch to the vent stack
A vent connecting at the junction of two fixture drains and serving as a vent
for both fixtures
A single vent that ventiliates multiple traps, in the case of back to back
fixture
A vertical vent that is the continuation of the drain to which the vents
connect
A vent that does not serve as drain and is located where if is not exposed
to back up of waste from a drainage pipe
See common vent
A branch vents that performs its functions for two or more traps
A pipe installed to vent, a fixture trap and w/c connects with the vent
system above the fixture served or terminates in the open air
A circuit vent which loop backs to connect with a stack vent instead of a
vent stack
Any vent connecting a horizontal branch or fixture drain with the stack
vent of the originating waste or soil stack
Is a pipe on the fixture side of the trap through which vapor or foul air is
removed from a room fixture
The principal artery of the venting system to which vent branches may be
connected
A vent installed so as to permit additional circulation of air between the
drainage and vent systems where the drainage systems might otherwise be
air bound
An arrangement of venting so installed that that one vent pipe will serve
two traps
The extension of a soil or waste stack above the highest horizontal drain
connected to the stack horizontal drain, the uppermost end above the roof
11/20
Roughing-in
Trap
Backpressure
Waste stack
Water distributing pipe
Soil pipe
COMMON VENT
CONTINOUS VENT
DRY VENT
DUAL VENT
GROUP VENT
INDIVIDUAL VENT
LOCAL VENT
MAIN VENT
RELIEF VENT
UNIT VENT
STACK VENT
WET VENT
YOKE VENT
BACKFLOW
BACK SIPHONAGE
BATTERY OF FIXTURE
BLANK FLANGE
BLIND FLANGE
CAULKING
PLUMBING REVIEWER
A short internally threaded section of pipe, used to join two pipes of
361
conduits
362 Used to connect the two ends of two pipes, neither of which can be turned
363
364
365
366
367
368
369
A short length of pipe with threads at each end; used to join couplings or
fittings
Is the extended portion of a pipe that is closed at one end to which no
connections are made on the extended portion
The length along the center of the pipe and fitting
Includes all piping within public or private which conveys sewage, rain
water or often liquid waste to a legal point of disposal but does not include
the main of a public sewer system or private or or public sewerage
treatment
Is a pipe connecting several fixtures
Is a device located at the bottom of the tank for the purpose of flushing
water closets and and similar fixture
A metallic sleeve, join to an opening of pipe, into which a plug is screwed
that can be removed for the purpose of cleaning
370 Is the lowest portion of the inside of any pipe or conduit that is not vertical
Includes water supply and distribution pipe; plumbing fixture and traps, soil
371 waste and vent pipes; house drain and house sewers including their
respective connections
Installation of all parts of the plumbing system which can be completed
372
prior to the installation of fixtures
A wye connections used on fire lines so that two lines of hose maybe
373
connected to the hydrant or to the same nozzle
374
Is any pipe which conveys the discharge of water closets of fixture having
similar function w/ or w/o the discharge of other fixtures to the building drain
Is the maximum vertical depth of liquid that a trap will retain measure
between the crown weir and the top of the dip of the trap
Install to be able to meet the water requirements during peak demands
376
from a low yielding water well
375
377 The device being used to eliminate the noise cause by water hammer
378 The location of water well to nearest septic vault
379 Slope of house sewer connected from the building to the main sewer
A passage under a road, embankment or canal which allow for the flow of
380
water
381 The third kind of water after the storm water and area water
382 The type of bathtub oher than sunken, square, free standing
383 Color coding of high pressure steam
384 Color coding for fuel oil division
The water column that seals the escape of unhealthy gases in the sanitary
385
drainage system
386 Service drop conductor clearance over the roof
A valve which in the water flow is shut off by a flat disk that is screwed
387
down onto its seat
388 An underground tank reservoir to store water
Another classification of storm drain, besides from inside drain and outside
389
drain
Tap used in high pressure water system with an interval valve to control
390
the flow of water
COUPLING
UNION
NIPPLE
DEAD END
DEVELOPED LENGTH
DRAINAGE SYSTEM
FIXTURE BRANCH
FLOOD LEVEL
FERRULE
INVERT
PLUMBING SYSTEM
ROUGH IN
SIAMESE CONNECTIONS
SOIL PIPE
TRAP SEAL
WATER RESERVOIR
SHOCK RELIEF AND
EXPANSION CHAMBER
50 FEET OR MORE
2 PERCENT
CULVERT
BLACK WATER
RECESSED
WHITE
BLACK
TRAP OR WATER SEAL
2.50 M
COMPRESSION VALVE
CISTERN
OVERHEAD STORM DRAIN
PRESSURE COCK
391
A valve which maintains uniform pressure on its outlet side regardless of its
pressure fluctuations on the inlet side above the pressure level
392
A pipe fitting within the interconnection of pipes for the purpose of easy
dismantling of the connection when needed
UNION PATENT
393
FLUSHOMETER
12/20
PRESSURE REDUCING
VALVE
CORPORATION STOP
AIR TRAP
396
397
398
399
400
PLUMBING REVIEWER
A trench containing course aggregate and a distribution tile pipe through
which septic tank effluent may flow covered with earth
The luminous flux density incident on a surface
An underground structure for drainage into which water from the roof or
floor will drain through sewer
A type of fitting for yoke bent
Minimum discharge pipe and fitting for bath tub
401 Minimum size of building sewer; it should not be less than the building drain
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
BATH FOOT
BATH SHOWER STALL
BATH SITZ
BATH TUB
BIDETS
COMBINATION FIXTURE
DRINKING FOUNTAIN
FLOOR DRAIN
FOUNTAIN CUPSIDERS
LAUNDRY TRAYS
SINKS (DISHWASHER)
SINKS (HOTEL OR PUBLIC)
SINKS (KITCHEN OR RESIDENCE)
SINKS (SMALL PANTRY OR BAR)
SLOP SINKS (ORDINARY)
SLOP SINKS (WITH COMBINE TRAP)
URINAL (PEDESTAL)
URINALS (LIP)
URINALS (STALL)
URINALS (THROUGH)
WASH BASIN (LAVATORIES)
WATER CLOSETS
424
Quiet, extermely sanitary. Like the siphon jet but having the flushing water
directed through the rim to create a vortex that scours the bowl
ABSORPTION TRENCH
ILLUMINATION
CATCH BASIN
WYE FITTING
1 1/2"
150mm DIAMETER
1 1/2"
2"
1 1/2"
1 1/2"
1 1/2"
1 1/2"
1 1/4"
2"
1 1/4"
1 1/2"
1 1/2"
2'
1 1/2"
1 1/4"
2"
3"
3"
1 1/2"
2"
2"
1 1/4"
3"
Sanitary, efficient very quiet. A toilet bowl into which the flushing water
425 enters through the rim and siphonic action initiated by a water jet draws the
contents of the bowl through the trapway
Moderately noisy. Similar to siphon jet except that trap passageway and
426
water surface area are smaller
Minimum cost. Least efficient subject to clogging, noisy. Simple washout
427 and emptying through small irregular passageway, prohibited by some
health codes
428 Noisy but highly efficient. Strong jet into leg forces contents out
A basin like fixture design to be struddled for bathing the genitals and
429
posterior parts of the body
430 1/2", 3/4", 1", 1 1/4", 1 1/2", 2, 2 1/2", 3", 4", 6", 8", 10", 12"
431 No building supply pipe shall be less than WHAT size in diameter
432 Minimum height of Fire Service Connection from the grade/floor
433 Maximum height of Fire Service Connection from the grade/floor
434 Minimum height of Dry Standpipe Outlet from the floor line
435 Maximum height of Dry Standpipe Outlet from the floor line
436 Considered extension of bulding drain outside the building wall
437 Fitting for base or soil stack and building drain
438 Wet standpipe for a riser not more than 15m
439 Wet standpipe for riser more than 15m
440 Dry standpipe for a riser below 23m
441 Dry standpipe for a riser more than 23m
Ratio of water closets for female population for elementary and secondary
442
school
Ratio of water closets for male population for elementary and secondary
443
school
444 Ratio of urinals for elementary schools
SIPHON-VORTEX
SIPHON-JET
REVERSE TRAP
WASH DOWN
BLOW OUT
BIDET
GI PIPE SIZES
19.05mm or 3/4"
46 cm.
122cm
61 cm.
122 cm
5 FEET
1/4" BEND ?
51mm or 2"
64mm or 2 1/2"
4"
6"
RATIO OF 1:25
RATIO OF 1:30
RATIO OF 1:75
445 Ratio of water closets for female population for principal worship places
RATIO OF 1:75
RATIO OF 1:5
13/20
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
PLUMBING REVIEWER
Minimum number of water closet required for female office and public
buildings
Minimum head of water required in section of plumbing for water test
It should not be used for steam
High Pressure
Exhaust Fan
Fresh Water, low pressure
Fresh Water, high pressure
Salt water piping
Oil Delivery
Oil Discharge
PNEUMATIC DIVISION
GAS DIVISION
FUEL OIL DIVISION
REFRIGERATING DIVISION
A full open type valve is used in several locations in a water distribution
system, which of the following does NOT require it?
A fireline system without a constant water supply and is equipped with a fire
service inlet and outlet connection installed exclusively for the use of Fire
Service
Term used to main water pipe delivering portable water to a building
464
Which poor design in the plumbing system causes water supply drop when
the fixture is simultaneously opened?
465
466
467
468
469
Not needed in sizing the vent pipe for individual branch and circuit vent
based on the total linear footage of the pipe making up the vent?
A hot and cold water supply pipes, where it is mix manually in desired water
470 temperature temperature and direct the mixed water either at the shower
head or at the fooe spout
Principle where a single lever valve used in kitchen sink and lavatory, they
471
are beautiful and maintenance free
Minimum water delivery in liters per minute for an outlet of a wet standpipe
472
at a residual pressure or 1.8 kilos per sq.mts
A female GI threaded pipe reducer fitting use to connect a reducing branch
473
pipe at an angle
474 General term used to described the fitting in the drawing
475 GI fitting used to accept the P trap assembly of the lavatory (drawing)
Type of vent applied on installations with multi branch interval where the
476 vertical vent pipe takes off in front of the first fixture and connects to a
main vent stack
477
478 Fire detector installed in a fire alarm system, which uses low melting point
479
480
481
482
483
484
485 Which is not a standard size of GI pipe for water supply? 2 1/2", 3",4",5"
14/20
4 CLOSETS
3 HEADS
GALVANIZED PIPING
WHITE
BUFF
BLUE
BLUE
GREEN
BRASS OR BRONZE
YELLOW
GRAY
BLACK
BLACK
BLACK
ON EVERY HOSE BIBB
DRY STANDPIPE
WATER SERVICE PIPE
INSUFFICIENCY IN THE SIZE
OF THE WATER SERVICE
AND DISTRIBUTION PIPE
1 "
1 "
64mm or 2 "
64mm or 2 "
SLOPE OF THE DRAIN PIPE
REVERSE OSMOSIS
FIXED TEMPERATURE
HEAT DETECTOR
COUPLING
PRESSURE REGULATOR
WRONG CHOICE OF VENT
TYPE
SUBMERSIBLE PUMP
jet,jack,reciprocating
5"
PLUMBING REVIEWER
Device in control valve which work by discharging instantaneous volume of
486
water at higher pressure
487
Term used for pipe extension of not more than 2 feet in length install in any
stack or branch of a plumbing rough in for the purpose of future trap
488 A full open valve located in a supply pipe to every water heater
Parking management system for two types of vehicular deterrent either
articulated arm type or straight beam type. It can be activated by means of
489
radio frequency remote control, push push button switch, photocell,
magnetic loop or acces control
490 Exception of fixture to be connected into a single trap
491 The presence of Fire Service Connection
Pipes and fittings which can exclusively be used for cold water lines for
492 potable main distribution water service, sprinkler and irrigation system. It
could be ", ", 1", 1 ", 1 " and 2"
493 Orange or brown in color with sizes of 4" and 3 meter in lengths of pipes
494
495 Least popular and not recommended use as potable water distribution pipe
496
497
498
499
500
501
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
ASBESTOS PIPE
Shower set for bath (drawing)
FIBER CEMENT PIPE
GATE VALVE
64mm or 2 1/2"
61 cms
AIR CHAMBER
VENT SIZE IS AT LEAST 1/2
THE DRAIN IT SERVES BUT
NOT LESS THAN THE
REQUIRED MINIMUM W/C
EVER IS LARGER
15/20
PLUMBING REVIEWER
AT EVERY BRANCH
INTERVAL OFA SOIL STACK
Interconnection of the same fixture in one soil or waste branch with one
branch vent
A single vent that ventiliates multiple traps, in the case of back to back
fixture
A parameter in sizing the drainage pipe
Conveys a discharge of solid and liquid wastes closets with or without the
discharged from other fixture to the house drain
Minimum size of standpipe for a building in which the highest outlet is 23 m
or less from the Fire service Connection
BATTERY OF FIXTURE
COMMON VENT
NUMBER OF FIXTURE
SOIL PIPE
102 mm (4")
In water distributon system which constantly rely its pressure from the main
528 water pipe apply only if the main fixture is supply continously with the flow
rate and minimum required working pressure
UPFEED OR DIRECT
METHOD
System of building which includes the water supply distribution pipes the
529 fixture and fixture traps, the soil waste and the vent pipes, the house drain
and the house sewer, the storm water drainage with their devices
PLUMBING SYSTEM
530 Minimum size of wet standpipe for riser of more than 15 mts from source
64 mm (2 1/2")
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
BALL
NUMBER OF BRANCH VENTS
535 Fitting installed at the base of the soil stack and a building drain
536
537
538
539
6"
SIAMESE CONNECTIONS
CENTRIFUGAL
JACK
555 Minimum distance of a water supply well from a seepage pit or cesspool.
45.70 mts.
30.50 mts.
26
51 mm.
16/20
559
560
561
562
563
564
565
566
567
PLUMBING REVIEWER
Maximum height of a water seal for each fixture trap.
Maximum length of the tailpiece from any fixture.
Minimum extension of the VSTR above the roof.
Minimum extension of the VSTR above an openable window, door opening,
air intake, or vent shaft.
Minimum trap diameter for a bathtub
Minimum trap diameter for a shower stall.
Required number of water closets for females for an auditorium serving 1635.
Required number of water closets for males for an auditorium serving 1635.
Required number of urinals for an auditorium serving 10-50.
568 Required number of water closets for females for a theater serving 51-100.
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
102 mm.
60 cms.
15 cms.
0.90 mtr.
38 mm. (11/2")
51 mm. (2")
3
2
1
4
Rigid and Flexible
Burr
House Drain
Polyethylene
Relief Vent
Escutcheon
Flush Valve
Sewage
Carbon Monoxide
Strom Sewer
1 1/2" (38mm)
1/8 Bend
1 1/2"
3/8"
TRUE
FALSE
Battery of Fixtures
Common Vent
4" (102mm)
4" (102mm)
Ball Valve
Zeolite
6" (150mm)
592 It refers to an individual who worked in the sanitary field of ancient Rome.
Plumbarius
Plumbum
17/20
Combination Waste
and Vent system
Air curtain
Air curtain
Sanitary Sewer Main
Fixture
2 1/2" (64mm)
Circuit Vent
Loop Vent
Barometer
PLUMBING REVIEWER
604 Bets type of fire detection that can detect fire during the incipient stage.
605 Condensing unit is a part of a ___.
Ionization
Refrigeration
606 A faucet fitted with a nozzle curving downward used as a draw-off tap.
607
608
609
610
Bibbcock
614 Ratio of water closets for female population for Principal Worship Places.
(1:75)
615
616
617
618
619
Minimum required number of water closets for female for office and public
buildings serving 55 occupants for employees.
Where there is exposure to skin contamination due to poisonous materials,
what is the ratio of lavatory to number of occupants.
Minimum head of water, in meters, required for each section of plumbing
for water test.
How many days, at least, shall be given before any plumbing work
inspection is done after written notice for inspection.
Minimum time, in minutes, required for water to stay in the system or pipes
for a water test without any leaks to satisfy said testing.
(1:30)
(1:25)
(1:75)
4
(1:5)
3
3
15 minutes
Atmospheric Vacuum
Breaker
8%
622
Minimum vertical distance from the bottom of water pipes to the top of
sewer or drain pipe if laid in the same trench on top of the other.
300 mm
623
300 mm
634 Minimum extension of a vent stack through roof above the roof.
Minimum extension of a vent stack through roof above any other vertical
635
surface.
Minimum vertical distance of VSTR from above of any openable window or
636
opening.
Minimum vertical extension of VSTR from any roofdeck where it is
637
protruded.
Minimum horizontal distance of any VSTR from a roofdeck used for other
638
purposes aside from protection from weather.
Minimum number of stories served by a waste stack requiring a parallel
639
ventstack.
640 The process of removing calcium and magnesium deposits in water.
True or false, number of fixture unit is one parameter in sizing a drainage
641
pipe.
18/20
4'
60
TRUE
TRUE
0.305 mtr. / 305 mm
0.45 mtr. / 450 mm
6.10 mts.
600 mm
4.60 mts.
TRUE
150 mm / 15 cms.
300 mm
0.90 mtr.
2.10 mts.
3.00 mts.
10
Softening
TRUE
PLUMBING REVIEWER
Water distribution system which constantly rely its pressure from the main
642 water pipe applied only if the highest fixture is supplied continuously with
the flow rate and minimum required working pressure.
643 What combination of pipe fittings is installed at the base of a soil stack?
A type of water closet that is least efficient, subject to clogging, noisy, and
use a simple washout action through a small irregular passageway.
This type of water closet is similar to that of the siphon-jet except that it has
648 a smaller trap passageway and smaller water surface area, moderately
noisy.
649
A type of water closet that is noisy but highly efficient. Strong jet into up leg
forces contents out. Use only with flush valve, requires higher pressure.
Water closet that is quiet, extremely sanitary, water is directed through the
rim. It scours bowl, folds over into jet; siphon.
A water closet that is sanitary, efficient, and very quiet. Water enters
651
through the rim and through the down leg.
650
652
A toilet bowl similar to the siphon-jet, but having the flushing water directed
to the rim to create circular motion or vortex which scours the bowl.
A toilet bowl in which the flushing water enters through the rim and a
653 siphonic action initiated by a water jet draws the contents of the bowl
through the trapway.
A water closet similar to that of the siphon jet but with a smaller water
654
surface and trapway.
655 This type of water closet is prohibited by some health codes.
The concussion and banging noise that results when a volume of water
656
moving in a pipe suddenly stops or loses momentum.
The length of a pipeline measured along the centerline of the pipe and pipe
657
fittings.
A shutoff valve closed by lowering a wedge-shaped gate across the
658
passage.
659 A valve closed by a disk seating on an opening in an internal wall.
Liquid sewage that has been treated in a septic tank or sewage treatment
660
plant.
661 The centerline of pipe.
662 The interior top surface of a pipe.
663 The interior bottom surface of a pipe.
664 Color code for pipes containing acid.
This shows the vertical relationships of all panels, feeders, switches,
switchboards, and major components are shown up to, but not including,
665
branch circuiting, it is an electrical version of a vertical section taken
through the building.
666
One of the earlier plastic to be developed in 1938, a du pont trade name for
the white, soft, waxy, and non-adhesive polymer of tetrafluoroethylene.
667
668
669
670
671
672
673
674
675
676
677
678
19/20
Washdown (WD)
Blowout (BO)
Siphon Vortex (SV)
Siphon Jet (SJ)
Siphon Vortex (SV)
Teflon