Вы находитесь на странице: 1из 4

Eccentric reducers and straight runs of pipe at pump suction | H...

Page 1 of 4

COPYING AND DISTRIBUTING ARE PROHIBITED WITHOUT PERMISSION OF THE PUBLISHER

Eccentric reducers and straight runs of pipe at pump suction


09.01.2010 | Bloch, H. P., Hydrocarbon Processing Staff,

Keywords: [pumps] [piping] [maintenance]


Questions relating to proper reducer application in centrifugal pump suction lines date back many decades. Until his death (at
age 84, in 1995), world-renowned pump expert Igor Karassik frequently corresponded with the writer and other pump users
on pump-related subjects. We rarely pass up an opportunity to highlight some of his experience-based comments.
Once, a pump user referred to Fig. 1 and noted that this was quite typical of illustrations found in many textbooks. In essence,
Fig. 1 indicates that, with a suction line entering the pump in the horizontal plane, the eccentric reducer is placed with the flat
at the top. Available texts often give no indication as to whether the pumpage came from above or below the pump.

Fig. 1. Illustration of eccentric reducer


mounting from
Hydraulic Institute Standards.

Igor Karassik agreed that, if the supply source was from above the pump, the eccentric reducer should be installed with the flat
(horizontal) surface at the bottom. Entrained vapor bubbles could then migrate back into the source instead of staying near the
pump suction. If the pump suction piping entered after a long horizontal run or from below the pump, the flat of the eccentric
reducer should be at the top.1
Still, in many older texts it has been assumed that the pumpage source originated at a level below the pump suction nozzle.
Karassik reminded us that older Hydraulic Institute Standards commented on the suction pipe slope:
...Any high point in the suction pipe will become filled with air and thus prevent proper operation of the pump. A straight
taper reducer should not be used in a horizontal suction line as an air pocket is formed in the top of the reducer and the pipe.
An eccentric reducer should be used instead.
This instruction applies regardless of where the pumpage originates. Depending on the particulars of an installation, trapped
vapors can reduce the effective suction line cross-sectional area. Should that be the case, flow velocities would tend to be
higher than anticipated. Higher friction losses would occur and pump performance would be adversely affected.
In the case of a liquid source above the pump suction, and particularly where the suction line consists of an eccentric reducer
followed by an elbow turned vertically upward and a vertical pipe lengthall assembled in that sequence from the pump
suction flange upstreamit will be mandatory for the eccentric reducer flat side to be at the bottom. That said, Fig. 2 should
clarify what reliability-focused users need to implement.

http://www.hydrocarbonprocessing.com/Article/2663961/Eccentri... 2/6/2015

Eccentric reducers and straight runs of pipe at pump suction | H... Page 2 of 4

Fig. 2. Suggested modifications for eccentric


reducer
mountings.

Also, whenever vapors must be vented against the flow direction, the line size upstream of any low point must be governed by
an important criterion. The line must be a diameter that will limit the pumpage velocity to values below those where bubbles
will rise through the liquid.
In general, it can be stated that wherever a low point exists in a suction line, the horizontal piping run at that point should be
kept as short as possible. In a proper installation, the reducer flange will thus be located at the pump suction nozzle and there
is usually no straight piping between reducer outlet and pump nozzle. Straight pipe lengths are, however, connected to the
eccentric reducer inlet flange. On most pumps, one usually gets away with five diameters of straight length next to the reducer.
In the case of certain unspecified velocities and other interacting variables (e.g., viscosity, NPSH margin, pump style, etc.), it
might be wise to install as many as 10 diameters of straight length next to the reducer inlet flange. The two different rules-ofthumb explain seeming inconsistencies in the literature, where both the 5 and 10-D rules can be found. HP
LITERATURE CITED
1

Karassik, Igor J., Centrifugal Pump Clinic, 2nd Ed., Marcel Dekker, Inc., 1989.

The author

Heinz P. Bloch is HPs Equipment/Reliability Editor. The author of 17 textbooks and over 470 papers or articles, he advises
process plants worldwide on reliability improvement and maintenance cost reduction opportunities. His coauthored
Bloch/Budris text, Pump Users Handbook, is comprehensive and very widely used. Find the 2nd edition under ISBN
0-88173-517-5. He can be contacted at HB@HydrocarbonProcessing.com.

Antony
01.28.2015

This article is really nice and it clears some myth.


For more detail about pump piping at
http://piping-info.blogspot.ca/2011/02/pump-piping-layout-design-guidelines.html

ali
06.06.2014

why use eccentric reducer in pump suction line

Manish Joshi
05.19.2014

Some of the EPCs using a standard where they use ecentric reducer at Pump suction with flat side
always at the top. Very valuable reference to ask them to be flexible with their standard if the pumpage
is from above the pump.
Thanks for bringing this clarity !!

susheel
05.12.2014

Eccentric are placed flat side down in line .

Great article ... I have argued this point with engineers who INSIST that a reducer shall be placed flat
side up, regardless of the source of the pumpage.

http://www.hydrocarbonprocessing.com/Article/2663961/Eccentri... 2/6/2015

Eccentric reducers and straight runs of pipe at pump suction | H... Page 3 of 4
pipingdesigners.c
om
Consider this article BOOKMARKED!
03.25.2014
I know I'll be pulling it out for reference.
Abdul
03.14.2014

Can we use eccentric reducer instead of concentric reducer if we do what will be the effect; is there any
disadvantage?... Coz one of the fitter had used eccentric instead of concentric in PSV connection.
Upper side Big Dia Lower side Small Dia
Please suggest
i want to know that the use of concentric and eccentric reducer.

01.08.2014

Pradip Sinha
01.08.2014

we have 8 nos high pressure pump (capacity 156m3/hr,max.pressure 15kg/cm2) with a single suction
header.
So, every month one of them pump shaft is being damaged.
I want solution.

Abid Bhatti
11.06.2013

Thanks for very help full article.

Mohamed
metawa
08.25.2013

thanks a lot .

varun
06.13.2013

As to why the eccentric reducer should be mounted with flat bottom at bottom for pumpage Source
above pump suction is still very unclear to me..Kindly elaborate the same

akshay
01.05.2013

Dear,
what benefits of eccentric reducer with 1",2" pipe at suction of C F pump? also which type of material
service & parameter required in pump (Viscocity,spe.gravity) are more suitable for eccentric reducer?

Mr.Piper007
08.30.2012

is there any possibility that concentric reducers be used on horizontal line piping?

mojtaba javan
06.11.2012

tanks for this paper.


www.mojtabajavan.ir

CHARLES
02.09.2012

Thanx for your info. Now i know.


Regards

Shankar
12.10.2011

Why should provide the eccentric reducer in the pump suction and why not provide concentric
reducer????......if any special purpose of providing the eccentric????...... pls give suggestion.....

02.28.2011

As to why the eccentric reducer should be mounted with flat bottom at bottom for pumpage Source
above pump suction is still very unclear to me..Kindly elaborate the same .
Rgds
Anirban

http://www.hydrocarbonprocessing.com/Article/2663961/Eccentri... 2/6/2015

Eccentric reducers and straight runs of pipe at pump suction | H... Page 4 of 4
Dear Sir,
09.23.2010
Please also include some guide line for
(1) straight length requirement for various types of Pumps i.e. OH2 / BB1 / BB2 / Multistage Pumps
and for type of Suction i.e. single / double suction
(2) If due to Lay out constrain can we go for 3D stratght length for suction
Waitng for your reply
Thanks,
Kiran

09.21.2010

09.20.2010

Thank God you clarified. There are innumerable references & books propagating the incorrect reducer
connection And there must be millions of incorrect installations. I as a project man (non Mech.) and
going by basic principals had argued with Pump specialists over this anomaly when a pump was
misbehaving but was shown the text book.
I had the priviledge to attend a pumping problems class led by Igor Karrasik. I still have the course
notes and have used them for over 30+ years.

Please read our Term and Conditions and Privacy Policy before using the site. All material subject to strictly enforced copyright
laws.
2014 Hydrocarbon Processing. 2014 Gulf Publishing Company.

http://www.hydrocarbonprocessing.com/Article/2663961/Eccentri... 2/6/2015

Вам также может понравиться