SPE 147855

The Best Practices In Moisture Control of Sour Natural Gas as Export


Gas: Case Study on Line Water Content Analyzer Assessment in a Gas
Plant
Gholamreza Bahmannia, SPGC

Copyright 2011, Society of Petroleum Engineers


This paper was prepared for presentation at the SPE Asia Pacific Oil and Gas Conference and Exhibition held in Jakarta, Indonesia, 2022 September 2011.
This paper was selected for presentation by an SPE program committee following review of information contained in an abstract submitted by the author(s). Contents of the paper have not been
reviewed by the Society of Petroleum Engineers and are subject to correction by the author(s). The material does not necessarily reflect any position of the Society of Petroleum Engineers, its
officers, or members. Electronic reproduction, distribution, or storage of any part of this paper without the written consent of the Society of Petroleum Engineers is prohibited. Permission to
reproduce in print is restricted to an abstract of not more than 300 words; illustrations may not be copied. The abstract must contain conspicuous acknowledgment of SPE copyright.

Abstract
The dry sour gas is 4th gas plant's main product for transfer and injection into Aghajari Oil Field as EOR projects.
Moisture control and monitoring in sour gas is a critical parameter because of severe corrosion problems that are associated
with sour gas. For assessment of Michell online process moisture analyzers, in comparison to laboratory Michells ceramic
moisture sensor and portable monitor (ASTM D-5454) and Chilled mirror device as manual dew point tester (ASTM D-1142),
a periodical test has been done. The results showed acceptable accuracy range of online analyzers and the calibration period
confirmed. In this paper all recorded data has analyzed by statistical methods.
1. Introduction
Based on ISO 14532:2005 (Natural gas Vocabulary) defines water dew point as The temperature above which no
detectable condensation of hydrocarbons occurs at a specified pressure. [11] The application of moisture analysers for the
measurement of natural gas is not simple and straightforward. There are many aspects to be considered that are unique to
natural gas and that can greatly affect the reliability of both the instrument in service and of the measurement data that it
provides.
The 4th gas plant (Phases 6-7-8) as member of the South Pars gas treating complex in south of Iran, north of Persian Gulf is
the largest plant in the world which has designed to treating and producing the dry sour natural gas for transfer and injection
into Aghajari Oil Field in EOR projects.(Fig.1)

Figure 1: The 4th gas treating plant facilities overall view

SPE 147855

Three 32 sub-sea pipelines transport well stream fluids produced at each wellhead platform, 105 km to the onshore treating
plant to produce the following products:
Table 1: The 4th Gas Plants main products
Product

Production Rate

Dry Sour Gas

93.5

Stabilized Condensate

159,000 [BBL/D]

LPG

4,452

[TON/D]

Rich Ethane Gas

9.5

[MMSCMD]

[MMSCMD]

Moisture control of export gas is a key and critical quality parameter in 4th gas plant and its efficiency is important in order
to meet pipeline needs and to prevent severe corrosion problems that are associated with sour gas if any droplet exist, to ensure
that the gas is safe to transport and has no risks.[6,2]Acuurately monitoring water dew point in sale gas is therefore vital if the
integrity and quality of the gas are to be maintained, and pipeline design conditions complied with. In 4th gas treating plant,
same other typical processing plants, after extraction from the gas field, natural gas is processed to remove water and heavy
hydrocarbon components, before transmission through the pipeline network. Figure 2 shows process units of this plant for the
removal of both excess moisture and heavy hydrocarbons. Dehydration process performs by molecular sieve beds and
hydrocarbon dew point control process is based on turbo-expander system. The composition of inlet gas shown in Table 2 and
it is clearly indicates presence of significant amount of acid gases, more than 4000 ppm H2S and about 2 mol percent carbon
dioxide content into saturated sour gas of South Pars field.

Figure 2: Process flow diagram of 4th gas treating plant


The dry sour gas pipeline design specifications and permissible moisture content was defined by gas national
transmission management as below that is vital quality control measures:

Water dew point @44barg : 0 degree C


H/C dew point @55barg : 0 degree C

For control and monitoring of water dew point in 4th gas plant, three kind of measurement devices are applicable now;
Ametek online process moisture analyzers, which are mounted in dehydration unit outlet streams, Michells ceramic moisture
sensor and portable monitor (ASTM D-5454) and Chilled mirror device as manual dew point tester (ASTM D-1142) which are
laboratory test. The question of paper is how we can sure that on-line analyzer measuring data is reliable through its
calibration periods?
2. Material and Methods
In order to demonstrate the on-line analyzer efficiency in 4th gas plant dehydration unit, following steps defined and
conducted by competent staff.Full composition test of dehydration feed was analyzed by gas chromatograph NGA-GC Type
C, VARIAN CP-3800. This test was done through weekly through six months and used for obtain natural gas
characteristics.As we know phase envelope with hydrate and water dew point curves is an excellent tool to find out what
form/phase water is in at operating conditions, during start-up, during shut-down and during upsets. The water content of a gas
depends on the system temperature, pressure and composition of the water containing gas. In this research, the curves was
plotted by ASPEN-HYSYS software. The 4th gas treating plant enjoys an on-line moisture analyzer on the outlet stream of
each dehydration unit for indication and control of dew point accurately, as process unit efficiency. In addition in order to

SPE 147855

evaluate this online analyzer, two other quality control devices were chosen as following table characterizations:
Table 3: Dew point measurement equipments
Equipment

Michell online analyzer

Michell
lab test

Chilled mirror

Model

CERMET II I.S

CERMAX
I.S

LT/DP-173000/M

Range
Prob.
Interval
Type
Calibration

To -100 C
Al2O3 Capac.
30 Sec
Electrical
6 months

To -100 C
Al2O3
15 min
Electrical
6 months

To -100 C
Mirror
Daily
Manual
-

The Cermet II hygrometer is a continuous, on-line instrument for the measurement of absolute moisture content in gas. It is
designed to operate under a wide range of conditions and provide for the monitoring and/or control of moisture in gases. The
instrument consists of two component parts: monitor and sensor, each of which is individually calibrated to a single standard
allowing combinations of sensor and monitor units to be totally interchangeable. The standard instrument covers the ranges 100 C to +20 C dew point (-148 F to +68 F dew point), g/m3, 0-9999 ppmv as well as 0-1000 lb/mmscf for natural gas.[7]
The CERMAX is an advanced portable instrument for the measurement of absolute moisture content of air or other gases. It
is designed to fulfill a wide range of applications by direct read out of moisture content displayed on the LCD display. The
instrument offers several customer selectable display options based on a calibrated dew point measurement range of -100 to
+20C.[8] The LT/DP-173000/M is a kind of Chilled mirror devices. The original purpose of the Bureau of Mines chilled
mirror device was to measure the water vapor dew point of the stream, so that its water vapor content could be determined
using a published correlation. The device has since been adapted to hydrocarbon dew point measurement as well, and the
recommendations of supplier apply to both applications. Commonly known as the Bureau of Mines Tester, the chilled mirror
hygrometer is a very simple and basic moisture measurement device that has been used for many years as a primary, absolute
moisture measurement tool.[1] In operation, the sample gas stream flows across a temperature controlled polished surface or
mirror. As the temperature of the mirror is slowly lowered, the water vapor will begin to condense or form dew on the
mirror. The temperature at which the dew first appears is considered the dew point. Once the temperature Dew point is
attained, a simple conversion using Existing charts or tables will provide the actual water Vapor content of the gas.[12]

Figure 4: Chandler dew point Tester,( Chilled mirror)

For logging and analysis of on-line analyzer efficiency, all required data (temperature, pressure, dew point... of gas stream)
was collected by process PIMS and laboratory competent personals through 6 months.

3. Results
3.1 Sour wet gas composition analysis
The average feed stream analysis is tabulated in Table 2 and Methan as majority gas component form the major part of
molecular weight.

SPE 147855

Table 2: Composition of inlet gas to plant

3.2 Phase envelope curves of feed gas


Figure 3 demonstrates the phase envelope curves of South Pars Gas field sour gas mixture which enter to process
units.

Figure 3: Phase envelope curves of South Pars Gas field

As shown in this figure, the presence of acid gases shifts all of the curves to the right. In other words, the presence of
acid gases increases the hydrate formation temperature considerably. It also increases the water dew point temperature. It
should be noted that the water dew point curves have been generated for a fixed amount of water content predicted at specified
separator condition.
3.3 Dew point data logging
In order to compare on line analyzer efficiency, all data was collected through six months, tabulated and plotted as
Fig. 4 during the 6 months calibration periods. Dew point measurement by chilled mirror device in maximum range (-35C)
was a confidence base for operators who would see as primary indication of normal dehydration efficiency.

Figure 4: Trend of three dew point devices

SPE 147855

It is clear that one disadvantage of the Bureau of Mines chilled mirror dew point tester is its subjectivity. Dew point
temperature measurements depend on the operators skill at controlling the refrigerant flow, and on the operators ability to
identify and interpret the condensation seen on the mirror. Improved measurement accuracy can be obtained by checking and
calibrating pressure and temperature instruments used with the dew point tester on a regular basis. However, certain sources of
bias uncertainty cannot be eliminated by calibration, and should be considered when assessing measurement accuracy.Table 4
shows two remain dew point measurement devices gathered comparable data during 180 days. Because of some process
requirement in maintenance jobs, there were some changes in data which are normal from operator point of view.

Table 4: Six months data collection trend(degree C)


On-Line
Analyzer
-100.1

Portable
Michell
-98.9

Chilled
Mirror
-35

-100.1

-100

-35

-0.1

-100.1

-98.7

-35

-1.4

-100.1

-99.2

-35

+1.9

-100.1

-97.7

-35

-2.4

-100

-99.2

-35

-0.8

-97.1

-96.2

-35

-0.9

-96.3

-95

-35

-1.3

-63.2

-61.2

-35

-2.0

-54.7

-55

-35

+0.3

-77.7

-78.1

-35

+0.4

-84.2

-85

-35

+0.8

-89.3

-87

-35

-2.3

-93.1

-90.2

-35

-2.9

-99.7

-99

-35

-0.7

-100.0

-98.9

-35

-1.1

Parameter
St. Deviation
Variance

On line analyzer
14.23141
202.53317

Deviation
-1.1

Portable Analyzer
13.99328
195.81196

Considering the 4th gas plant process condition changes and dewpoint deviations between on line analyzer and portable lab tester, standard
deviation of dew point in on line device and portable one were 14.23 and 13.99. The calculated F-ratio (F=Sonline2/Sportable2) be obtained as
1.034, which is much greater than critical F-ratio. This high difference shown that those itemst variances have statistically highly significant
difference with 99.6% significance level.
The student-t statistics for comparison of two equipment dew point measuremnet is calculated as -98.3. This value is also much greater than
critical student-t value, indicating that the average have highly differences with 99.7% significance level.Hence, the data and also F-ratio and
student-t statistics show that considerable close data has been obtained. In other word, the dew point accuracy for on line analyzer
confirmed as below by pracical measurements through six month monitoring :

2.0 C between 60 C & -100 C


1.0 C between +20 C & -60 C
This results changed as below for dew point measurment through one year re-calibration period:

3.2 C between 60 C & -100 C


2.3 C between +20 C & -60 C
The first results are very close to on line dew point analyzers manufacturer reported performance for one year re-calibration period. The
Chilled mirror device was applied as measurement basis up to -75C in some cases.

SPE 147855

Figure 5: Phase envelope curves of dry sour gas


For adapting of some of analysis based on composition of dry sour gas, the new phase envelope curve was plotted after GC test. Figure 5
shows that expected water dew point will occur after dehydration due to its physical properties.

4. Conclusion
The application of a moisture analyser for sour gas measurement requires a sensing technology that can perform
satisfactorily in practice.[4,13] This paper demonstrates that on line dew point analyzer through six months re-calibration
period will act in the lowest error range in comparison with other calibrated and trusted devices.In other hand Cermet II as on
line hygrometer has acceptable accuracy in practice. Statistical information indicates that the vast majority of failures are
caused either by incorrect sampling methods, sampling positions or inadequate protection against harmful substances. The
frequency of re-calibrations required in order to maintain the performance of the Cermet II hygrometer is primarily dependent
on the composition of the gas to which the sensor is exposed: i.e. content of liquid and particulate contaminants, corrosive
elements, etc. In 4th gas treating plant application, half annual re-calibration ensures that the stated accuracy of the Cermet II
hygrometer is maintained. It seems that the new TDLAS(tuneable diode laser absorption spectroscopy) type hygrometer as a
new dew point measurement device enables natural gas processing and transportation facilities to monitor moisture content in
real time with high precision and reliability It is the first technique to monitor the gas itself, rather than monitoring a reaction
or a change on the surface of a sensor. It combines a high degree of accuracy with an extremely good speed of response.
5.

References

1. Deaton, W.M., Frost E.M., Jr., Bureau of Mines Apparatus for Determining the Dew Point of Gases Under Pressure. Bureau of Mines Report of
Investigation 3399, May 1938.
2.

Bukacek, R.F., Equilibrium Moisture Content of Natural Gases, Research Bulletin 8. Institute of Gas Technology, Chicago, USA, 1955.

3. ASTM designation D 1142-95, Standard Test Method for Water Vapor Content of Gaseous Fuels by Measurement of Dew-Point Temperature.
American Society for Testing and Materials, Philadelphia, USA, 1995.
4.
Oellrich, L.R., Althaus, K., Relationship Between Water Content and Water Dew Point Keeping in Consideration the Gas Composition in the
Field of Natural Gas. GERG Technical Monograph TM 14. Fortschritt-Berichte VDI, Nr 679, 2002.
5. Robinson, J.N., Wiekert E., Moore R.G., Heidemann R.A., Charts help estimate H2O content of sour gases. The Oil and Gas Journal (USA), February 6,
1978, pages 77-78.
6. NACE Standard MR0175-97, Standard Material Requirements: Sulfide Stress Cracking Resistant Metallic Materials for Oilfield Equipment. National
Association for Corrosion Engineers, Houston, USA, 1997.
7. CERMET II Hygrometer Installation, Operation and Maintenance Manual,2009,pages 4-6
8. CERMAX Portable Hygrometer Installation, Operation and Maintenance Manual,2009,pages 4-6
9. , Darin L. George, Reducing Measurement Uncertainty In Process Gas Quality Measurements, San Antonio, Texas, USA, 2006
10. Torbjorn V. Lokken, Water Content of High Pressure Natural Gas; Data, ,Prediction and experience from Field, Statoil Hydro Research Center, 2007,
Page 3-5
11. Andy Benton, Dew Point Measurements in Natural Gas, Natal Brazil, 2010, page 3-4
12. Chandler Process Instruments General Catalogue, 2010, Page 1
13. John J. Carroll, The Water Content of Acid Gas and Sour Gas From 100F to 220F and Pressures to 10000 PSIA,CANADA,2003,page 2

6. Acknowledments
At first I would like to dedicate my special thanks to all my colleagues in 4th gas treating plant in SPGC who support me for data gathering
and analysis, especially Mr. F.Bahmani head of process engineering and Mr. A.Sabet our laboratory and quality control head.I would like to
dedicate my special thanks for SPGC and NIGCs R&D supports and contributions as well.