5.12
THROTTLE CONTROL/GOVERNORS
There are two types of engine governors that are used with throttle controls. The engine
governors are:
The Automotive Limiting Speed Governor (ALSG) for torque control, typical governor for
on-highway applications(refer to section 5.12.1)
The Power Take-off (PTO) for speed control, typical variable speed governor (VSG) for
off-highway applications (refer to section 5.12.2)
5.12.1
In on-highway applications and some nonroad applications, ALSG is the primary throttle source.
The throttle input in a ALSG sets percent load. The amount of fuel input to the engine is
determined by the throttle position. As the load on the engine varies the resulting engine speed
will vary between idle speed and rated speed.
5-73
FEATURES
Figure 5-17
An Idle Validation Switch is required and uses two digital inputs. Refer to section 4.2, "Digital
Inputs," for additional information.
5.12.2
POWER TAKE-OFF
PTO control is available to fuel the engine in order to keep the selected PTO speed regardless of
engine torque without driver interaction. The engine torque cannot exceed a programmed limit.
Upon startup the engine will go to the speed selected by the PTO throttle position.
The PTO throttle control options are:
Cab PTO Cruise Switch PTO
Remote PTO
Analog PTO
5-74
NOTE:
Software version Rel. 12.0 or later, the park brake function could be enabled/disabled
and the logic for the park brake may be inverted.
See Figure 5-18 for a diagram of PTO logic.
Figure 5-18
PTO Logic
5-75
FEATURES
5-76
Figure 5-19
5-77
FEATURES
Type
VCU
Pin
Default
Parameter ID
Cruise Master
Switch
18/6
1 = Enabled
1 13 27
Service Brake
Switch (optional)
21/15
1 = Enabled
1 13 05
1 11 26
Transmission Type
18/2
Set/Coast Switch
18/4
1 = Enabled
1 13 23
Resume/Accel
Switch
18/5
1 = Enabled
1 13 22
21/16
1 = Enabled
1 13 07
Table 5-49
The parameters listed in Table 5-50 can be set with VEPS or the minidiag2.
5-78
Parameters
Description
Default
Range
Parameter
ID
PTO Function
0 = Disabled
1 = Enabled
1 11 01
1200 RPM
1 11 02
500 RPM
1 11 03
PTO Throttle
Override
0 = Disabled
0 = Disabled
1 = Enabled
1 11 04
Max Engine
Speed for
Throttle Override
1400 RPM
0 3000 RPM
1 11 05
PTO Dropout on
Service Brake
Switch
1 = Enabled
(Service Brake
Switch will
disable PTO)
0 = Disabled
1 = Enabled
1 11 06
PTO Dropout on
Clutch Switch
1 = Enabled
(Clutch Switch
will disable PTO)
0 = Disabled
1 = Enabled
1 11 07
Max Vehicle
Speed in PTO
9.6 km/h
0 128 km/h
1 11 08
950 RPM
1 11 09
600 Nm
0-5000 Nm
1 11 11
Cruise Resume
PTO Speed
950 RPM
1 11 12
Resume PTO
Max Engine
Torque
600 Nm
0-5000 Nm
1 11 14
200 RPM/sec
25 2500 RPM/sec
1 11 15
1 = Park Brake
must be applied
for PTO operation
1 11 30
1 = Enabled (park
brake required)
1 11 31
Enable Park
Brake with PTO
Table 5-50
5-79
FEATURES
5-80
Figure 5-20
5-81
FEATURES
Parameters
Description
Default
Range
Parameter
ID
PTO Function
0 = Disabled
1 = Enabled
1 11 01
1200 RPM
1 11 02
500 RPM
1 11 03
PTO Throttle
Override Enable
1 = Enabled
0 = Disabled
1 = Enabled
1 11 04
1400 RPM
0 3000 RPM
1 11 05
1 = Enabled
(Service Brake
Switch will
disable PTO)
0 = Disabled
1 = Enabled
1 11 06
PTO Dropout on
Service Brake
Switch
PTO Dropout on
Clutch Switch
1 = Enabled
(Clutch Switch
will disable PTO)
0 = Disabled
1 = Enabled
1 11 07
9.6 km/h
0 128 km/h
1 11 08
200 RPM/sec
25 2500 RPM/sec
1 11 15
1 to 3
1 11 16
950 RPM
1 11 17
600 Nm
1 11 19
950 RPM
1 11 20
600 Nm
1 11 22
950 RPM
1 11 23
600 Nm
1 11 25
1 = Park
Brake must be
applied for PTO
operation
1 11 30
Enables/Disables the
requirement to use the park
brake status when in PTO mode
1 = Enabled
(park brake
required)
0 = Disabled (park
brake not required)
1 = Enabled (park
brake required)
1 11 31
PTO Speed #3
5-82
Table 5-51
Installation
The Remote PTO Switch is wired to pin 18/10 of the VCU/ADM2FR. See Figure 5-21.
Figure 5-21
Analog PTO
A Remote Accelerator Pedal can be installed to control either an analog Remote PTO (VSG) or
analog Remote Accelerator Pedal (ALSG).
The Remote PTO will start when the Remote PTO switch is switched to battery ground. The
Remote PTO logic will override the Cab PTO. Cab throttle and remote throttle are also overridden
unless PTO Throttle Override is disabled. When ALSG operation is required, the Remote
Accelerator Switch is switched to battery ground.
The Remote Accelerator Switch Select input (VCU, 18/7) determines the active throttle control.
When this pin is grounded, the engine will respond to the remote throttle input. When this input is
not grounded, the engine will respond to the cab throttle pedal.
The PTO Enable input (VCU, 18/10) determines if the engine will be in VSG or ALSG mode.
If remote PTO is active and then disabled due to one or more disabling condition, PTO mode will
automatically reactivate when the disabling condition is removed.
5-83
FEATURES
Installation
See Figure 5-22 for installation of a Remote Accelerator Control for PTO or ALSG.
Figure 5-22
5-84