Vickers®

Piston Pumps

Axial Piston Pumps


Fixed and Variable Displacement
PFB 5, PFB 10, PFB 20
PVB 5/6, PVB 10/15, PVB 20/29, PVB 45 and PVB 90 to SAE
PVB 5/6, PVB 10/15, PVB 20/29 to DIN/ISO 3019, Part 2

GB-2379B
Contents

Basic characteristicts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.3


General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.3
Functional symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.3
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.4
Operating data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.5
Minimum Inlet Pressure Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.5–A.6
Performance data @ 1500 r/min drive speed:
PFB5, PFB10, PFB20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.7
PVB5, PVB6, PVB10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.8
PVB15, PVB20, PVB29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.9
PVB45, PVB90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.10
Performance data @ 1800 r/min drive speed:
PFB5, PFB10, PFB20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.11
PVB5, PVB6, PVB10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.12
PVB15, PVB20, PVB29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.13
PVB45, PVB90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.14
Control data for PVB pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.15
Noise levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.16
Installation data
PFB5 SAE flange mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.17
PFB10 SAE flange mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.18
PFB20 SAE flange mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.19
PVB5/6 SAE flange mounting C & CM pressure compensator controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.20
PVB5/6 side ported thru shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.21
PVB10/15 SAE flange mounting C & CM pressure compensator control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.22
PVB10/15 side ported thru shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.23
PVB5/6 & PVB10/15 M lever control, & H handwheel control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.24
PVB20/29 SAE flange mounting C & CM pressure compensator control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.25
PVB20/29 side ported thru shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.26
PVB45 flanged mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.27
PVB45 foot mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.28
PVB90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.29
PVB5/6, PVB10/15 & PVB20/29 CC & CMC pressure compensator and adjustable maximum displacement stop . . . . . . A.30
PVB5 – 29 CG Remote control compensator, CVP Load sensing & –S30 drain port option . . . . . . . . . . . . . . . . . . . . . . . . . A.31
PVB5/6, PVB10/15, PVB20/29 DIN/ISO models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.32
Installation data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.33

A.2
Basic Characteristics Typical Section
Type . . . . . . . . . . . . . Axial piston pumps Variable displacement model with compensator control “C” or “CM”
Operating pressure . . . . . up to 210 bar
(3000 psi)
Displacement . . . . . 10,5 to 197,5 cm3/r
(0.64 to 12 in3/r)
Drive speed . . . . . . . . . up to 3600 r/min

General Description
Both fixed and variable displacement
models make up this range of axial
piston pumps. Their high performance
ratings and efficiencies are achieved
with a variety of hydraulic fluids. Fixed
displacement models are noted for their
volumetric and mechanical efficiencies.
Variable displacement models can
closely match pressure and/or flow
demand with a control selected from:
 Pressure compensator with or
without a remote control facility.
 Pressure compensator with
adjustable displacement control.
 Load sensing compensator.
 Mechanical (lever) control.
 Handwheel control

Functional Symbols
PFB PVB
Fixed displacement Variable displacement
models models
With handwheel,
or lever.

With pressure With pressure compensator With CVP load sensing


compensator (C or CM) arranged for remote control and pressure limiter
(simplified symbol) C(M)G (detailed symbol)

A.3
Model Codes

P * B ** - (F)- (M) * * (F) (X) (*)-** - ** - (C) - (G) - (L) - ** - ****

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 Basic models 9 Shaft type 13 Pressure compensator variations


F = Fixed displacement type N = Metric, to DIN/ISO 3019, Part 2 PVB5 to 29 models only:
V = Variable displacement type and VDMA 24560, Part 1 G = Remotely adjustable pressure
Y = SAE models P*B5 to 15 only. setting.
2 Displacement Omit for 20 thru 90 models Omit when not required.
PFB and PVB models:
10 Pump design number 14 Control location
5 = 10,55 cm3/r (0.64 in3/r)
10 = 21,10 cm3/r (1.29 in3/r) 10 = PFB20 PVB5 to 15 models with “H”, “M” or “V”
20 = 42,80 cm3/r (2.61 in3/r) 30 = PFB10 controls only:
PVB models only: 31 = PVB10 and PVB15 L = Left hand, when viewed at shaft
6 = 13,81 cm3/r (0.84 in3/r) 20 = all other models end.
15 = 33,00 cm3/r (2.01 in3/r) Omit for right hand, or when a pressure
29 = 61,60 cm3/r (3.76 in3/r) 11 Displacement control options compensator is fitted.
45 = 94,50 cm3/r (5.76 in3/r) PVB models only.
90 = 197,50 cm3/r (12.0 in3/r) C = Pressure compensator. Pressure 15 Control design number
adjustment range: PVB models only.
3 Foot mounting option PVB90: 19 to 210 bar (275 to 10 = “H” and “M”controls;
3000 psi) also “C” control for PVB90
F = Foot mounting option for PVB45 and
All other models: 17 to 210 bar 11 = “C” and “CM” controls.
PVB90 models.
(250 to 3000 psi) 12 = “CVP” control.
Omit for flange mounting.
Also used as prefix for item 12 20 = “CG” control.
Note. For foot mounting brackets. for
other models see bottom of page. Note. For PVB6, 15 and 29 models, the
user must ensure that the max. pressure 16 Special design options
4 Mounting flange setting never exceeds 140 or 100 bar For PFB5 and PVB5 to 29 only:.
M = Metric, to DIN/ISO 3019, Part 2 (2000 or 1500 psi) dependent on the S.30 = Extra drain port to permit
and VDMA 24560, Part 1 type of fluid being used. vertical “shaft-up” installation.
Omit for SAE mounting flange
CM = Pressure compensator. Option
For PVB5 to PVB29 pressure
for all sizes except PVB90.
5 Shaft rotation compensated models only:
Pressure adjustment range:
Viewed at shaft end GE1 = 10% minimum displacement.
PVB45: 10 to 100 bar (150 to
R = Clockwise when pressure compensated.
1500 psi)
L = Anticlockwise (not avalable for All other sizes: (17 to 100 bar
PFB10 and PFB20) For all models:
(250 to 1500 psi)
GEVS= Pressure setting knob with
CVP = Load sensing with pressure
key lock.
6 Displacement zone limiter.
PVB models only. Omit when not required.
S = One side of center (pressure PVB5 to 15 only:
compensated models only) H = Handwheel control
D = Both sides of center (Handwheel M = Lever control
and lever controlled models only) V = No control (As for “M” type but
Omit for PFB models. without lever.)
Omit for PFB models. Foot bracket mounting kits
7 Flanged main ports Order separately if required. Kits include
F = PVB45 and PVB90 models only. 12 Maximum displacement pump fixing bolts.
Omit for P*B5 to 29 inclusive. adjustment
PVB5 to 29 models only: Model Part For pump sizes:
C = “C” or “CM”compensator, and code number
8 Thru shaft option FB-A-10 422582 P*B5/6
PVB5 to 29 only: with 12
Omit when not required. FB-B-10 422583 P*B10/15 and PFB20
X = Thru shaft (with side entry ports) FB-C-10 422584 PVB20/29
Omit for PVB45 and PVB 90, or if not
required.
A.4
Operating Data

Pressure and Speed Limits

Basic model Geometric Maximum shaft Maximum outlet


designation dispalcement, speed (r/min) pressure, bar (psi)
cm3/r (in3/r)
Anti-wear Water-in– Water- Anti–wear Water Water-in–
hydraulic oil glycol hydraulic glycol oil
oil emulsion oil emulsion
(40%/60%) (40%/60%)

PFB5 10,55 (0.64) 3600 210 (3000)


PFB10 21,10 (1.29) 3200 1800 1800 210 (3000) 175 (2500) 175 (2500)
PFB20 42,80 (2.61) 2400 175(2500)

PVB5 10,55 (0.64) 210 (3000) 140 (2000) 140 (2000)


PVB6 13,81 (0.84) 140 (2000) 100 (1500) 100 (1500)
PVB10 21,10 (1.29) 210 (3000) 140 (2000) 140 (2000)
PVB15 33,00 (2.01) 1800 1800 1800 140 (2000) 100 (1500) 100 (1500)
PVB20 42,80 (2.61) 210 (3000) 140 (2000) 140 (2000)
PVB29 61,60 (3.76) 140 (2000) 100 (1500) 100 (1500)
PVB45 94,50 (5.76) 210 (3000) 140 (2000) 140 (2000)

PVB90 197,50 (12.0) 1800 1200 1200 210 (3000) 140 (2000) 140 (2000)

Maximum Inlet Pressure


All pumps except PVB5/6/10/15 with H, M or V controls . . . . . . . . . . . . . 1,0 bar (15 psi)
PVB5/6/10/15 with H, M or V controls . . . . . . . . . . . . . . As “Max. outlet pressure” above
for appropriate size.
Case Drain Pressure
See “Installation data” section, on page A.33.

Minimum Inlet Pressure


See following graphs.
Based on oil viscosity of 21 cSt (102 SUS) and at 50C (120F).

PFB5 and PVB5 PVB6

psi bar bar psi psi bar bar psi


Supercharge pressure

Supercharge pressure

1,8 0,8 1,8 0,8


10 10
Absolute pressure

Absolute pressure

30 1,6 0,6 30 1,6 0,6

1,4 0,4 1,4 0,4


25 5 25 5
1,2 0,2 1,2 0,2
20 20
1,0 0 0 1,0 0 0
15 Vacuum: 15 Vacuum:
0,8 170 m bar 0,8 170 m bar
10 0,6 (5 Hg) 10 0,6 (5 Hg)
0 600 1200 1800 2400 3000 3600 0 600 1200 1800 2400 3000
3200
Drive speed, r/min Drive speed, r/min

A.5
Operating Data Minimum Inlet Pressure (cont’d)

PFB10 and PVB10 PVB15


psi bar bar psi psi bar bar psi

Supercharge pressure
15

Supercharge pressure
1,8 0,8 2,0 1,0
Absolute pressure

Absolute pressure
30 10
1,6 1,8 0,8
0,6 30 10
25 1,6 0,6
1,4 0,4 25
5 1,4 0,4
20 5
1,2 0,2 20
1,2 0,2
15 1,0 0 0 15 1,0 0
Vacuum: 0
Vacuum:
10 0,8 170 m bar 10 0,8 170 m bar
(5 Hg)
0,6 0,6 (5 Hg)
0 2000 2400 2800 3200 1200 1800 2400 3000
Drive speed, r/min Drive speed, r/min

PFB20 PVB20 and PVB29


psi bar bar psi psi bar bar psi
Supercharge pressure

40 25

Supercharge pressure
1,8 0,8 2,6 1,6
25 10 35 2,4 1,4 20
Absolute pressure
Absolute pressure

1,6 0,6 2,2 1,2


30 2,0 1,0 15
20 1,4 0,4
5 1,8 0,8
25 10
0,2 1,6 0,6
1,2
20 1,4 0,4 5
15 1,0 0 0 1,2 0,2
Vacuum: 15 0 0
1,0
0,8 170 m bar Vacuum:
0,8
10 (5 Hg) 10 170 m bar
0,6 0,6 (5 Hg)
0 600 1200 1800 2400 0 1400 1600 1800 2000 2200 2400
Drive speed, r/min Drive speed, r/min

PVB45 PVB90
psi bar bar psi psi bar bar psi
Supercharge pressure
Supercharge pressure

1,8 1,8
0,8 0,8
25 10 25 10
1,6 1,6
Absolute pressure

Absolute pressure

0,6 0,6
1,4 0,4 1,4 0,4 5
20 5 20
1,2 0,2 1,2 0,2

15 1,0 0 0 15 1,0 0 0
Vacuum: Vacuum:
0,8 170 m bar 0,8 170 m bar
10 (5 Hg) 10 (5 Hg)
0,6 0,6
0 1800 1900 2000 2100 2200 0 1200 1400 1600 1800
Drive speed, r/min Drive speed, r/min

A.6
Performance Data at 1500 r/min Drive Speed

With oil at 21cSt (102 SUS) and at 49C (120F): Atmospheric inlet
For data at drive speed of 1800 r/min, see pages A.11 to
A.14

PFB5
US gpm L/min kW hp Nm lbf in
100
400
80 10 40
300
60 5 20 30
10
4 15 200
40 5 20
3
10 5
20 2 100
5 10
1
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure

PFB10
100 US gpm L/min kW hp Nm lbf in

80 800
25
80
60 10 40 15 20 600
60
8 30 15
40 10 400
6 20 40
10
20 4 200
5 20
10 5
2
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure

PFB20
100 US gpm L/min kW hp Nm lbf in
250
2000
80
30 200
20 1500
60
150
20 80 15 20
1000
40 60 100
10
10 40 10
20 50 500
20 5
0 0 0 0 0 0 0
0 50 100 150 175 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 psi
Outlet pressure

A.7
Performance Data at 1500 r/min Drive Speed (cont’d)

With oil at 21cSt (102 SUS) and at 49C (120F): Atmospheric inlet
For data at drive speed of 1800 r/min, see pages A.11 to A.14
PVB5 US gpm L/min kW hp Nm lbf in
100
400
80 10 40
60 20 300
5 10 30
4 15
40 1 5 200
3 20
10 5
2 2 100
20 10
1 5
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)

PVB6
100 US gpm L/min kW hp Nm lbf in
300
80 25 6 8
30
6 250
5
60 20 6 200
4 20
4 15 150
40 3 4
10 3 100
2 2 10
20 2 1 2
5 50
1
0 0 0 0 0 0 0
0 50 100 140 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 psi
Outlet pressure
1 = Delivery with compensator setting of 70 bar (1000 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi)
3 = Delivery with compensator setting of 140 bar (2000 psi)

PVB10
100 US gpm L/min kW hp Nm lbf in
30
80 20 800
25 80
60 10 40 15 20 600
60
8 30 15
40 1 10 400
6 20 40
2 10
20 4 200
5 20
2 10 5
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)
A.8
Performance Data at 1500 r/min Drive Speed (cont’d)

With oil at 21cSt (102 SUS) and at 49C (120F): Atmospheric inlet
For data at drive speed of 1800 r/min, see pages A.11 to A.14
PVB15 US gpm L/min kW hp Nm lbf in
100 800
80 700
80
600
14 60
60 15 60 8 10 500
400
6 8 40
40 10 40 1 300
6
4
20 2 4 20 200
20 5
2 100
2
0 0 0 0 0 0 0
0 50 100 140 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 psi
Outlet pressure
1 = Delivery with compensator setting of 50 bar (750 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi)

PVB20
100 US gpm L/min kW hp Nm lbf in
250
2000
80 30 200
20 1500
60 150
20 80 15 20
1000
40 60 100
1 10
10 40 3 4 10
20 2 50 500
20 5
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 35 bar (500 psi) 3 = Delivery with compensator setting of 175 bar (2500 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi) 4 = Delivery with compensator setting of 200 bar (3000 psi)

PVB29
100 US gpm L/min kW hp Nm lbf in
250
80 2000
30 200
25 100 20 1500
60 150
20 80 15 20
2 3 1000
40 15 60 100
1 10
10 40 4 10
20 50 500
5 20 5
0 0 0 0 0 0 0
0 50 100 140 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 psi
Outlet pressure
1 = Delivery with compensator setting of 35 bar (500 psi) 3 = Delivery with compensator setting of 175 bar (2500 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi) 4 = Delivery with compensator setting of 200 bar (3000 psi)
A.9
Performance Data at 1500 r/min Drive Speed (cont’d)

With oil at 21cSt (102 SUS) and at 49C (120F): Atmospheric inlet
For data at drive speed of 1800 r/min, see pages A.11 to A.14

PVB45
100 US gpm L/min kW hp Nm lbf in

400
80
3000
60 60 80 300

60 2000
40 150 200
40 40
30 100 2 40
20 1 1000
20 20 100
50 20
10
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)

PVB90
100 US gpm L/min kW hp Nm lbf in

175 1000
80 125 8000
150
800
60 100 125 6000
75 100 600
80 300
40 75 4000
60 50 400
200 2
40 1 50
20 200 2000
20 100 25
25
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)

A.10
Performance Data at 1800 r/min Drive Speed

With oil at 21cSt (102 SUS) and at 49C (120F): Atmospheric inlet
For data at drive speed of 1500 r/min, see pages A.7 to A.10

PFB5
US gpm L/min kW hp Nm lbf in
100
400
80 40
15 300
60 25 10
6 30
5 20 10
40 4 20 200
15
3 5
10 5
20 2 10 100
1 5
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure

PFB10
100 US gpm L/min kW hp Nm lbf in

25 35
80 800
30
50 20 80
60 12 25 600
40 15 60
10 20
40 8 30 15 400
10 40
6 20 10
20 4 20 200
10 5 5
2
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure

PFB20
100 US gpm L/min kW hp Nm lbf in
250
2000
80
25 200
30 1500
60 20 150
20 80 15 20 1000
40 100
60 10
20 10 40 10 50 500
20 5
0 0 0 0 0 0 0
0 50 100 150 175 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 psi
Outlet pressure

A.11
Performance Data at 1800 r/min Drive Speed (cont’d)

With oil at 21cSt (102 SUS) and at 49C (120F): Atmospheric inlet
For data at drive speed of 1500 r/min, see pages A.7 to A.10
PVB5 US gpm L/min kW hp Nm lbf in
100
400
80
40
15
25 10 300
60 6
20 30
5 10
40 4 15 1 200
20
3 5
10 2 5
20 2 10 100
1 5
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)

PVB6 US gpm L/min


100 kW hp Nm lbf in

10 300
80 8 30 7 30
250
6 8
60 25
6 5 200
20 6 20
4 150
40 4 15 3 4
3 100
10 1 2 2 10
20 2 2 50
5 1
0 0 0 0 0 0 0
0 50 100 140 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 psi
Outlet pressure
1 = Delivery with compensator setting of 70 bar (1000 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi)
3 = Delivery with compensator setting of 140 bar (2000 psi)

PVB10
100 US gpm L/min kW hp Nm lbf in

25 35
80 800
30
20 80
50 25
60 12 600
40 15 60
10 20
40 8 30 1 15 400
10 40
6 20 2 10
20 4 20 200
5 5
2 10
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)
A.12
Performance Data at 1800 r/min Drive Speed (cont’d)

With oil at 21cSt (102 SUS) and at 49C (120F): Atmospheric inlet
For data at drive speed of 1500 r/min, see pages A.7 to A.10

PVB15 US gpm L/min kW hp Nm lbf in


100 800
80 700
80
600
20 80 10 16 60
60 14 500
15 60 8 10 400
1 40
40 6 8 300
10 40 6
4 200
20 2 4 20
5 20 2 2 100
0 0 0 0 0 0 0
0 50 100 140 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 psi
Outlet pressure
1 = Delivery with compensator setting of 50 bar (750 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi)

PVB20
100 US gpm L/min kW hp Nm lbf in
250
2000
80
200
25
30 1500
60 20 150
20 80 15 20 1000
40 100
60 1
3 4 10
20 10 40 2 10 50 500
20 5
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 35 bar (500 psi) 3 = Delivery with compensator setting of 175 bar (2500 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi) 4 = Delivery with compensator setting of 200 bar (3000 psi)

PVB29 US gpm L/min kW hp Nm lbf in


100
250
80 2000
25 200
30 120 30 1500
60 20 150
25 100
20 80 2 3 15 20 1000
40 100
15 60 1
4 10
20 10 40 10 50 500
5 20 5
0 0 0 0 0 0 0
0 50 100 140 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 psi
Outlet pressure
1 = Delivery with compensator setting of 35 bar (500 psi) 3 = Delivery with compensator setting of 175 bar (2500 psi)
2 = Delivery with compensator setting of 100 bar (1500 psi) 4 = Delivery with compensator setting of 200 bar (3000 psi)
A.13
Performance Data at 1800 r/min Drive Speed (cont’d)

With oil at 21cSt (102 SUS) and at 49C (120F): Atmospheric inlet
For data at drive speed of 1500 r/min, see pages A.7 to
A.10

PVB45
100 US gpm L/min kW hp Nm lbf in

400
80
3000
80
60 100 300
200 60 80 2000
50
40 200
40 150 60
2 40
30 100 1 40 1000
20 20 20 100
10 50 20
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)

PVB90
100 US gpm L/min kW hp Nm lbf in

1000
80 150 200 8000
125 175 800
60 150 6000
100 125 600
100 400
40 80 75 100 4000
300 400
60 2 50 75
200 1
20 40 50 200 2000
20 100 25
25
0 0 0 0 0 0 0
0 50 100 150 210 bar
Efficiency, % Delivery Input power Torque
0 500 1000 1500 2000 2500 3000 psi
Outlet pressure
1 = Delivery with compensator setting of 100 bar (1500 psi)
2 = Delivery with compensator setting of 200 bar (3000 psi)

A.14
Control Data for PVB Pumps

Controls available as indicated in “Model “CG” Pressure Compensator, “M” Lever Control
Code” section. Remotely Controlled Provides mechanical or manual variation
Same as the “C” compensator, but of pump delivery in approximate
“C” and “CM” Pressure arranged for remote pressure proportion to the angular movement from
Compensators adjustment by suitable pilot controls. the center position. This control may be
Automatically adjusts pump delivery at One or more pilot relief valves (e.g. operated on both sides of center
pre-adjusted pressure to match system C-175-*) and/or pilot directional valves, permitting bi-directional flow
demand. Delivery can decrease rapidly in series or in parallel, can provide many characteristics. The pintle-mounted lever
from maximum to zero through a varied remote pilot systems. control must be secured by suitable
pressure gradient typically 4 to 6 bar (60 linkage to maintain desired settings;
to 90 psi) with normal circuit volumes. Your Vickers representative will be both extremes of pintle travel are limited
pleased to advise on optimum by internal stops to approx. 17.5 from
For pressure adjustment ranges see arrangements for individual applications.
“Model Code”. center.
Note: “CV” Load Sensing Comensator, Control torques (approx. at 1500 r/min).
1. When using PVB6, 15 or 29 pumps Remotely Controlled PVB5 . . . . . . . . . . . . . 3,8 Nm @ 210 bar
with “C” type compensators ther user Automatically matches pump delivery to (33 lbf in at 3000 psi)
must ensure that the maximum system demand at a pressure PVB6 . . . . . . . . . . . . . 2,7 Nm @ 138 bar
pressure setting never exceeds 140 approximately 17 bar (250 psi) above (24 lbf in at 2000 psi)
or 100 bar (2000 or 1500 psi) load pressure. This pressure difference PVB10 and PVB15 . . 7,5 Nm @ 70 bar
dependent on the type of fluid being can be created by: (66 lbf in at 1000 psi)
used. – a variable flow restrictor (non-
Caution. It is possible to compensated flow control) or the Note: Torque varies with pressure and
mechanically adjust the spool opening of a directional control speed.
compensator up to 210 bar valve.
(3000 psi). “GE1” Minimum Displacement
Both forms can be used with fixed and Control
2. It is recommended that, as for other
variable speed pump drives. In the latter Option for C(M)(C) and CG(C)
types of positive pump, a relief valve
case a fixed restrictor can provide pre- compensators to limit the minimum
should be fitted externally as
set, near-constant pump flow displacement, in the fully compensated
protection against overloads. Where
independent of drive speed, provided mode, to nominally 10% of full
a relatively large amount of fluid is
that the speed exceeds that which gives displacement.
directly subject to compensator
the required flow at full displacement. An
pressure, it may be possible to omit Hydraulic Fluids
external pressure limiter must be added
the relief valve. Consult your Vickers All pumps can be used with anti-wear
to prevent overloading the pump; see
representative. hydraulic oils, water glycols and
“Functional Symbols” page A.3.
“CC” and “CMC” Pressure water-in-oil (invert) emulsions. It is
The matching of pump pressure and possible to use these pumps with high
Compensators with Adjustable Max.
delivery to system demands provides water base fluids (e.g. 5%/95%
Displacement Stop
power matching and conservation by oil-in-water emulsion) at pressures up to
The pressure compensator section
minimizing system power wastage. 70 bar (1000 psi). However, first consult
performs as described above. The
adjustable stop allows the maximum your Vickers representative.
“H” Handwheel Control
pump delivery to be adjusted between Provides manual variation or selection of The extreme operating viscosity range
25 to 100%. To assist priming, adjust the pump delivery. The control can be is from 220 to 13 cSt (1020 to70 SUS)
stop setting to provide at least 40% of operated on both sides of center for all pumps (except where 5%/95%
the maximum displacement. permitting bi-directional flow emulsions are used). The
characteristics. recommended running range is 54 to
Approximate change of displacement 13 cSt. (245 to 70 SUS)
per one turn of handwheel is:
PVB5 . . . . . . . . . . . . . 2,6 cm3 (0.16 in3) The viscosity of 5%/95% emulsions is
PVB6 . . . . . . . . . . . . . . 3,4 cm3 (0.21 in3) near-constant at about 1 or 2 cSt
PVB10 . . . . . . . . . . . . . 5,2 cm3 (0.32 in3) (<35 SUS).
PVB15 . . . . . . . . . . . . . . 8,2 cm3 (0.5 in3)

A.15
Temperature Limits * To obtain maximum service life from both - Drive Methods
Minimum ambient . . . . . . . –20C (–4F) fluid and hydraulic system, 65C (150F) Direct co-axial drive through a suitable
Maximum ambient. . . +70C (+158F) normally is the maximum temperature except flexible coupling is preferred. If an
for water-containing fluids. Whatever the indirect drive is to be used, first consult
Fluid Temperatures actual temperature range, ensure that your Vickers representative.
Mineral Water- viscosities stay within the limits specified in
oil containing Filtration Requirements
“Hydraulic Fluids” section.
Mininmum –20C +10C 20/18/14 or ISO 18/14..
(–4F) (+50F) Drive Requirements:
- Direction of Rotation
Maximum* +80C +54C
Clockwise or anti-clockwise (viewed at
(+176F) (+129F) shaft end) to order; see also “Model
Code”, and “Installation Dimensions”
sections.
Noise Levels
* Typical values equivalent to NFPA
Noise level – dB(A)*
Speed r/min Pressure bar (psi) Stroke PVB5 PVB6 PVB10 PVB15 PVB20 PVB29
Full flow 51 52 54 58 – –
35 (500)
Cutoff 51 51 44 47 – –
Full flow 54 55 56 60 – –
70 (1000)
Cutoff 52 54 49 54 – –
1000
Full flow 56 57 60 62 – –
140 (2000)
Cutoff 58 56 55 59 – –
Full flow 60 – 61 – – –
210 (3000)
Cutoff 59 – 59 – – –
Full flow 50 51 55 60 – –
35 (500)
Cutoff 52 51 48 51 – –
Full flow 54 55 57 61 74 70
70 (1000)
Cutoff 56 57 51 54 – –
1200
Full flow 59 59 60 63 74 73
140 (2000)
Cutoff 59 60 54 58 69 76
Full flow 60 – 62 – 78 –
210 (3000)
Cutoff 61 – 56 – – –
Full flow 54 54 58 63 – –
35 (500)
Cutoff 52 52 51 52 – –
Full flow 58 58 60 64 – –
70 (1000)
Cutoff 57 57 55 55 – –
1500
Full flow 61 62 62 66 – –
140 (2000)
Cutoff 62 59 62 59 – –
Full flow 64 – 65 –– – –
210 (3000)
Cutoff 62 – 63 –– – –
Full flow 57 58 61 64 – –
35 (500)
Cutoff 55 57 55 56 – –
Full flow 60 61 63 67 76 77
70 (1000)
Cutoff 59 58 59 60 – –
1800
Full flow 63 66 65 69 81 81
140 (2000)
Cutoff 62 63 62 64 75 81
Full flow 64 – 67 – 81 –
210 (3000)
Cutoff 64 – 65 – – –
A.16
PFB5 SAE Flange Mounting 3rd angle
projection

Installation Dimensions in mm (inches)

Optional foot bracket, shown in dashed


outline; kit FB-A-10 comprises foot
bracket and two pump fixing bolts bolts. Case drain port 9/16-18 UNF-2B for
Order separately, if required. SAE O-ring fittings: 2 ports
4 holes 44,5
3/ –16 UNC-2B thread
8
142,2 (5.6)
(1.75)
(foot bracket) 106,4 85,9
(4.19) (3.4)
135 (5.3) 12,7
Ø95,3 (0.5)
(3.75 dia)

34
(1.34)
Ø130
69,8 (5.12 dia)
(2.75)
12,7
(0.5) Alternate
drain port
12,7 12,7
79,2 (0.5)
2 holes (0.5)
(3.125) 32,5
Ø11,1 (0.437 dia)
50,8 (2.0)
(pump flange) 127,0 (1.28)
(5.0) 59,4
152,4 4 holes Ø11,1 (2.34)
(0.437 dia) 93 (3.7)
(6.0)

Key: 4,8 (0.19) Square


98,6 x 25,4 (1.0) long
(3.9)
21,13/21,00
(0.832/0.827)
ROTATION
43,7
OUT IN
(1.72)
103,1 Ø82,55/82,50
A B (3.250/3.248 dia)
(4.06)
43,7 NI
OUT
47,3
(1.72) ROTATION (1.86)
Ø19,05/19,02
(0.750/0.749 dia)

57,2 7,6 6,4


(2.25) (0.3) (0.25)
Inlet/outlet ports:
11/16-12 UNF-2B thread for SAE O-ring fittings.

View on rear end of pump Detail of shaft, key


and locating diameter

A.17
PFB10 SAE Flange Mounting
Installation Dimensions in mm (inches)

Optional foot bracket, shown in dashed


Case drain port 3/4-16 UNF-2B for SAE
outline; kit FB-B-10 comprises foot O-ring fittings: 2 ports
bracket and two pump fixing bolts bolts.
Order separately, if required.
B
87,9
A (3.46)
Ø120,6
(4.75 dia) 12,7
2 holes in pump flange: (0.5)
Ø174,8 Ø14,3 (0.563 dia)
(6.88 dia)

180,8 45,7
(7.12) (1.80)

92,1
(3.63)

12,7
(0.5)
Alternative drain
98,6 12,7 port
D
(3.9) (0.5)
146 4 holes: 50,8
E
(5.75) Ø11,2 (0.44 dia) (2.0)
177,8
(7.0)

Key:
114,3 6,35 (0.25) Square 9,5
(4.5) (0.375)

25,12/24,87
ROTATION (0.989/0.979)
OUT IN 62,7 (2.47)
Ø101,60/101,55
A B (4.000/3.998 dia)
133,3 (5.25)

Ø22,22/22,20
(0.875/0.874 dia)
62,0
(2.44)
C
Inlet/outlet ports:
15/8-12 UNF-2B thread for SAE O-ring fittings.
Detail of shaft, key
and locating diameter
View on rear end of pump

Pump A B C D* E*
type
PFB10-*-30 44,4 213,9 33,3 26,9 59,4
(1.75) (8.42) (1.31) (1.06) (2.34)
PFB10-*Y-30 58,7 228,1 47,6 41,1 73,7
(2.31) (8.98) (1.87) (1.62) (2.9)
*Omit for foot bracket models)

A.18
PFB20 SAE Flange Mounting

Installation Dimensions in mm (inches)


Optional foot bracket, shown in dashed
outline; kit FB-B-10 comprises foot
bracket and two pump fixing bolts bolts. Case drain port 3/4-16 UNF-2B
Order separately, if required. for SAE O-ring fittings: 2 ports

262,9
Ø120,6 (10.32)
58,7 130,0
178,0 (4.75 dia)
(2.31) (5.12)
(7.0) Ø174,8
2 holes
R.H. Shaft Rotation
(6.9 dia) 14,2
Ø14,3 (0.56 dia)
(0.56)

181,0
(7.13)
4 holes
Ø11,1 43,7
(0.437 dia) (1.72)
92,1
(3.63)

41,0 Alternative
(1.61) 12,7 drain port
12,7 98,3
(0.5) (3.87) (0.5)
146,0 73,6 50,8
(5.75) (2.9) (2.0)
92,7
171,4 (3.65)
(6.75)

47,8
(1.88) 9,5
Key: (0.375)
144,3 7,9 (0.31) Square
(5.7)

35,33/35,08
(1.391/1.381)

146,0 Ø101,60/101,55
152,4 (6.0) A B (5.75) (4.000/3.998 dia)
73,2
(2.88)
7,8 Ø31,75/31,70
(0.31) (1.250/1.248 dia)
82,5
(3.25)
Inlet/outlet ports (see table):
15/8-12 UNF-2B thread for SAE O-ring fittings.
View on rear end of pump Detail of shaft, key
and locating diameter
Shaft Inlet Outlet
rotation port port
RH B A
LH A B

A.19
PVB5/6 SAE Flange Mounting:
Pressure Compensator Control - “C” and “CM”

Installation Dimensions in mm (inches)


See also “Control Data” section, page Optional foot bracket, shown in dashed
A.15. outline; kit FB-A-10 comprises foot Case drain port 9/16-18 UNF-2B for
bracket and two pump fixing bolts bolts. SAE O-ring fittings: 2 ports
Order separately, if required. 44,4
177 (6.9)
(1.75)
Compensator position for: 162,8 (6.41)
R.H. rotation models
L.H. rotation models 108,7 (4.23)
106,4 69,8
(4.19) R20,6 (2.75)
135 (5.3) Height (0.8 rad) 12,7
R.H. Shaft
of foot bracket Rotation (0.5)

2 holes
Ø11,1 (0.437 dia)
33,5
(pump flange)
(1.32)
Ø130
69,8 (5.12 dia)
(2.75)
12,7
(0.5)
79,4 12,7
R47,8 (3.125) (0.5)
(1.9 rad) 59,4
50,8 (2.0)
127,0 (2.34)
4 holes (5.0)
3/ –16 UNC-2B thread 4 holes Ø11,1 93 (3.7)
8 152,4
(foot bracket) (6.0) (0.437 dia) 163,5 (6.44)

Caution: While pump is operating do Key: 4,8 (0.19) Square


not back compensator adjustment x 25,4 (1.0) long
screw out beyond dimension shown.

84,8 28,4 21,13/21,00


(3.34) (1.12) (0.832/0.827)

Ø82,55/82,50
79,2 (3.250/3.248 dia)
(3.12)

A B Ø19,05/19,02
38,1 (0.750/0.749 dia)
(1.50) 52,3
(2.06)
6,4
(0.25)
57,2 Alternate drain Detail of shaft, key
(2.25) port and locating diameter
135,9
(5.35)

Inlet/outlet ports (see table): Shaft Inlet Outlet


11/16-12 UNF-2B thread for SAE O-ring fittings. rotation port port
RH A B
View on rear end of pump LH B A

A.20
PVB5/6 Thru-Shaft Models (with Side Ports)

Installation Dimensions in mm (inches)


Maximum output torque is 40 Nm (354 For other dimensions and installation
lbf in), less unput torque at system data see page A.20.
pressure, see performance curves:
At 1500 r/min drive speed, page A.8.
At 1800 r/min drive speed, page A.12.

4,77/4,75 (0.188/0.187) Outlet port for RH rotation models;


square key both ends Inlet port for LH rotation models:
153,2 15/16-12 UN-2B thread for SAE O-ring fittings.
(6.03)
17,91/17,78
(0.705/0.700)

29,5
(1.16) A B

Ø15,82/15,8
(0.623/0.622 dia)
177,0 165,1
(6.97) (6.50)
213,4
(8.40)
Inlet port for RH rotation models;
Outlet port for LH rotation models: 73,15
15/16-12 UN-2B thread for SAE O-ring fittings. (2.88)

51,3
(2.02)

A.21
PVB10/15 SAE Flange Mounting
Pressure Compensator Control - “C” and “CM”

Installation Dimensions in mm (inches) Optional foot bracket, shown in dashed


See also “Control Data” section, page outline; kit FB-B-10 comprises foot
bracket and two pump fixing bolts bolts. Case drain port .750-16 UNF-2B for
A.15. SAE O-ring fittings: 2 ports
Order separately, if required.
58,7 207,8
(2.31) (8.18)
193,8
Compensator position for: (7.63)
R.H. rotation models 123,7
L.H. rotation models (4.87)
74,7
Ø120,6 Ø174,8
(2.94)
(4.75 dia) (6.88 dia) 12,7
(0.5)

174,6
(6.9)
.500-13 UNC
-2B 45,7
thd. 4 holes (1.80)
2 holes
Ø14,3 92,1
(0.563 dia) R.H. Shaft
(3.63)
Rotation
41,1
98,6 (1.62)
(3.9) 146 12,7 12,7 (0.5)
(5.75) (0.5)
73,7 50,8 (2.0)
187 4 holes (2.9)
(7.36) Ø11,2 (0.44 dia)
189,0
Caution: While pump is operating do (7.44)
not back compensator adjustment
screw out beyond dimension shown.
89,3 137,1
(3.5) max (5.4) max
28,4 84,8 Key: 6,4 (0.25) Square
(1.12) (3.34) x 22,3 (0.88) long 9,5
23,9 28,4 (1.12) (0.375)
(0.94)
25,12/24,87
(0.989/0.979)
82,5 (3.25)
52,3 (2.1)
Ø101,60/101,55
A B (4.000/3.998 dia)
65 (2.56)

Ø22,22/22,20
(0.875/0.874 dia)
66,5 Alternative drain port
(2.62)
Inlet/outlet ports (see table): 47,8
1.625-12 UN-2B thread for SAE O-ring fittings. (1.88)

View on rear end of pump Detail of shaft, key


and locating diameter
Shaft Inlet Outlet
rotation port port
RH A B
LH B A

A.22
PVB10/15 Thru-Shaft Models (with Side Ports)

Maximum output torque is 83 Nm (735 lbf For other dimensions and installation
in), less unput torque at system pressure, data see page A.22.
see performance curves:
At 1500 r/min drive speed, pages A.8 &
A.9.
At 1800 r/min drive speed, page A.12 &
A.13.
4,79/4,76 (0.1885/0.1875) Outlet port for RH rotation models;
174,5 square key x 25,4 (1.0) long Inlet port for LH rotation models:
(6.87) 15/8-12 UN-2B thread for SAE O-ring fittings.
21,13/21,00
(0.832/0.827)

31,75 (1.25)
A B

Ø19,05/19,02
308,8 (0.750/0.749 dia)
196,9
(12.16) (7.75)
Inlet port for RH rotation models;
Outlet port for LH rotation models:
15/8-12 UN-2B thread for SAE O-ring fittings. 90,4
(3.56)

65,3
(2.57)

A.23
PVB5/6 and PVB10/15 Manual/Mechanical Controls

Lever Control - “M” and No Control - “V”


Units with this control may be operated on
both sides of center permitting bi-directional
fluid flow characteristics. A
35
B
76,2 (3.0) 6,4
R 9,7 (0.25)
(0.38 rad)
Position 1 Position 2
Ø6,4
(0.25 dia)
127
(5.0)

A B

Lever may be set at 15,7


any position in 360 (0.62)
circle. Ensure clamp
Shaft Lever Outlet bolt is fully tightened. Pump A B
rotation position port type
Ø17,40/17,27
RH 1 A (0.685/0.680 dia) PVB5/6 153 68,9
2 B (6.02) (2.7)
LH 1 B PVB10/15 204 99,9
2 A No Control - “V” (8.04) (3.93)

Handwheel Control - “H”


Units with this control may be operated on
both sides of center permitting bi-directional
fluid flow characteristics.
Max. flow adjustment. A
Adjust and lock B
to limit max. flow. 37,3 (1.47) Ø57,2
15,7 C
(2.25 dia)
(0.62) R24
Ø6,3 (0.95 rad)
Position 1
(2.25 dia)

62 (2.5 )
Caution! max.
Loosen lock
screw before A B
turning handle. 43,7
Re-tighten after (1.72 )
adjusting flow.

65,7 Position 2 35,3 (1.39)


(2.6)

Shaft Pointer Handwheel Outlet Pump A B C


rotation position rotation from zero port type
RH 1 Clockwise A PVB5/6 200 129 70,6
2 Counter-clockwise B (7.87) (5.08) (2.78)
1 Clockwise B PVB10/15 250 140 93,5
LH
2 Counter-clockwise A (9.84) (5.51) (3.68)

A.24
PVB20/29 SAE Flange Mounting
Pressure Compensator Control - “C” and “CM”

Installation Dimensions in mm (inches) Optional foot bracket, shown in dashed


See also “Control Data” section, page outline; kit FB-C-10 comprises foot
bracket and two pump fixing bolts bolts. Case drain port .750-16 UNF-2B
A.15. for SAE O-ring fittings: 2 ports
Order separately, if required.
58,9 295,0
(2.32) (11.62)
221,7
226,0
(8.9) 123,4 (8.73)
(4.86)
181,0 Ø146,0 84,8
2 holes (7.125) (5.75 dia) (3.44)
R.H. Shaft 15,7
Ø17,5 (0.69 dia) Rotation
(0.62)
Ø212,8
(8.38 dia)
215,9
(8.5)
4 holes 53,8
Ø17,5 (2.1)
(0.69 dia)
109,5
(4.31)

39,9
(1.6)
15,7 50,8 50,8 17,3 (0.68)
(0.62) (2.0) (2.0)
234,9 19,0
(9.25) 76,2 (3.0)
(0.75)
265,2 128,5
(10.5) (5.1)

Caution: While pump is operating do


not back compensator adjustment
screw out beyond dimension shown.

28,4
84,8 (3.34)
(1.12) Key: 7,9 (0.31) Square
x 31,7 (1.25) long 9,5
41,1 (1.62)
(0.37)
35,33/35,08
(1.391/1.381)
95,2 (3.75)
66,5 (2.62)
189,0 Ø127,00/126,95
A B (7.44) (5.000/4.998 dia)
59,2 (2.3)

Ø31,75/31,70
(1.250/1.248 dia)
82,5
(3.25) Alternative drain port
Inlet/outlet ports (see table): 47,7
1.625-12 UNF-2B thread for SAE O-ring fittings. (1.88)

View on rear end of pump Detail of shaft, key


and locating diameter
Shaft Inlet Outlet
rotation port port
RH A B
LH B A
A.25
PVB20/29 Thru-Shaft Models (with Side Ports)

Maximum output torque is 159 Nm For other dimensions and installation


(1408 lbf in), less unput torque at data see page A.25.
system pressure, see performance
curves:
At 1500 r/min drive speed, page A.9
At 1800 r/min drive speed, page A.13

365,25
(14.38)
306,1 Key: 6,35 (0.25) square
(12.05) 85,3 x 25,4 (1.0) long
(3.36)
29,96
(1.14)

69,85 93,2
(2.75) (3.67)

Ø25,37/25,35
(0.999/0.998 dia)
Ø38,1 35,7
(1.50 dia) (1.406)
235,7 .500-13 UNC-2B thread 8 places
(9.28) for 11/2 SAE 4-bolt flange
277,1
(10.91)

58,9 (2.32) min.

Port B:
Outlet port for RH rotation models. B
Inlet port for LH rotation models.

111,2 148,8 260,0


(4.38) (5.86) (10.24)

Port A:
Inlet port for RH rotation models.
Outlet port for LH rotation models. A

A.26
PVB45 Flange-Mounted Model

407,0
(16.0)
145,3
(5.72)
81,79 308,0
(3.22) (12.13)
Compensator adjuster: 15,75
38,1 (1.5) A/F hex. (0.62)

Drain connection: 1.0625-12 UNF 2B 35,0 CAUTION:


thread for SAE O-ring fittings (2 ports). (1.38) While pump is
operating do not
Key 38,1 (1.5) back compensator adjuster
11,1 (0.437) square screw out beyond this
dimension.

Ø152,4/152,35
(6,000/5.998 dia) 49,43
(1.945/1.935)
110,3
(4.34)
Ø44,45/44,40
(1.750/1.748 dia)

66,67 (2.625)
187,4 Alternative drain port.
(7.38)

299,0
(11.77)
127,0
.3750-16 UNC 2B thread x 4 slots 19,8 (0.78) wide for (5.0)
12,0 (0.47) deep for lifting mounting bolts. (Use of backing
eye-bolt. washers is recommended)

312 4
(12.3)
290
(11.42) 161,6 IN
77,8 101,6
(6,34) (3.062) (4.0)
square OUT

141,0
(5,55)

To suit SAE 4-bolt port flanges: 2 ports Ø50,8


8 holes .500–13 UNC 2B thread (2.0 dia)
x 27,0 (1.06) deep
200,2 (7,88) 42,9 (1.688)
square Direction of
shaft rotation
View on shaft end of pump View on rear end of pump

A.27
PVB45 Foot-Mounted Model

For other dimensions and installation


data see page A.27 .
69,1
(2.72)
66,67
(2.625)

317,4
(12.5)
165,1
(6,5)
square

146,0
(5.75)

25,4
282,6 (1,0)
(11.125) 104,4 165,1 21,8
333,4 (4.1) (6.5) (0.86)
(13.125)
62 62 60,4 60,4
(2.5) (2.5) (2.38) (2.38)
352,6 206,5
(13.9) (8.13)
4 holes Ø16,7 (0.68 dia)
1 hole Ø8,5 (0.335 dia) for 1 hole Ø8,5 (0.335 dia) for
dowelling; front foot only dowelling; rear foot only

A.28
PVB90

Foot mounting option (designated by


Model Code = “F”) is shown in dotted
outline. An alternative base mounting 68,25 396,7
facility is provided by four tapped holes (2.69) (15.62)
in the bottom face of the pump - see 365
page A.30. (14.4)
351,5
Compensator adjuster: (13.84)
38,1 (1.5) A/F hex. 156,5
(6.16) 35,0
Drain connection: CAUTION:
(1.38)
1.3125-12 UN 2B thread for SAE  While pump is
O-ring fittings (2 ports). 38,1 operating do not
(1.5) back compensator
Key 11,1 (0.437) square 
x 44,5 (1.75) long adjuster screw out beyond
this dimension.

127,0 (5.0)
49,40/49,15
(1.945/1.935)

111,2 (4.38)

Ø152,4/152,35 Ø44,45/44,40
(6,000/5.998 dia) (1.750/1.748 dia)
12,7
(0.5) Drain connection:
1.3125-12 UN 2B thread
 Location of tappings for lifting
eye-bolts,: 2 at shaft end; 1 at rear: 79,2 215,9 4 holes Ø16,7 (0.66 dia)
.3750-16 UNC 2B thread x 12,0 (0.47) (3.12) (8.5)
deep. 130,0
(5.12) 260,3
187,5 (10.25)
329
(12.95) (7.38)
Ø228,6 (9.0 dia) 4 holes Ø20,6 (0.81 dia) at 45 from 139,7
vertical/ horizontal center lines. (5.5)
63,5 center line to 88,9
(2.5) drain port (5.5)
2 ports
Ø60,4 (2.4 dia)

163,8 167,6
(10.24) (10.48)

200 A B
50,8
(7,9)
(2.0)
square
190,5 139,7
(7.5) (5,5)

To suit SAE 4-bolt port flanges:


8 holes .500-13 UNC 2B thread x 27,0 (1.06) deep
393,7 View on rear end of pump
(15.5)
438,1 Shaft Inlet Outlet
(17.25) rotation port port
View on shaft end of pump RH A B
LH B A
A.29
PVB90 cont’d

Detail of tappings in base of pump.

Shaft end 212,7


of pump (8.375)

4 holes tapped .6250-12


130,2 UNC-2B x 28 (1.1) deep
(5.125)

PVB5/6, PVB 10/15 and PVB20/29 with Pressure Compensator


and Adjustable Maximum Displacement Stop:
Control Types “CC” and “CMC”
For general dimensions and
installation data of these pumps,
see pages A.20, A.22 and A.25 Note.
Compensator position for:
Caution: While pump is operating do PVB5/6-*LSY (LH rotation models) and
not back compensator adjustment PVB10/15 -*RSY (RH rotation models)
screw out beyond dimension  shown. PVB20/29 -**SY (RH and LH rotation models)
A Fully extended  28,4  28,4
(1.12) (1.12)
B F E
17,3
(0.68) H

23.9
(0.94
A/F
G
C
D
A B

Adjusting rod
Minimum delivery position (screw flush
with nut); do not adjust below flush. Note.
Compensator position for:
PVB5/6-*RSY (RH rotation models) and
PVB10/15 -*LSY (LH rotation models)
Pump A B C D E F G H
type
PVB5/6 233 195 50 22,9 76,2 94,4 94,4 _
(9.17) (7.68) (1.97) (0.9) (3.0) (3.72) (3.72)
PVB10/15 266 226 52,3 25,1 118 70,8 90,2 23,8
(10.47) (8.9) (2.06) (0.99) (4.65) (2.79) (3.55) (0.94)
PVB20/29 294 254 66,5 41,9 _ 53,3 104,4 41,1
(11.56) (10.0) (2.62) (1.65) (2.1) (4.11) (1.62)

A.30
PVB5 to 29 with “CG” Remote Control of Compensator

Type “GEVS” .4375-20UNF-2B thread for SAE Caution: Effective


“CG” control models, connect to compensator setting will be
compensator control setting
43 74,6 external valve.
plus remote relief valve setting.
(1.7) (2.94) Note. Do not operate pump with
this port plugged. Adjustment procedure
1. Turn remote pressure control
(such as C-175) anti-clockwise to
minimum setting.
2. Turn compensator adjustment plug
Ø35 (1.4 dia) to desired minimum pressure - 17
bar (250 psi) or higher.
3. Full pressure range can now be
obtained with remote pressure
control.
45,0
(1.77)
Location as shown for: Location as shown in dotted outline for:
PVB5/6 LH rotation models, PVB5/6 RH rotation models and
PVB10/15 RH rotation models and PVB10/15 LH rotation models.
PVB20/29 LH and RH rotation models.

“CVP” Load Sensing with Pressure Limiter


Load sensing control port:
55,0 45,5 .4375-20 UNF-2B thread
(2.17) (1.8) for SAE O-ring fittings.
40,69 22,0
(1.6) (0.87)

19,0 (0.75)

Ø28,5
Location as shown for:  to mounting (1.12 dia)  PVB5/6 . . . . . . . . . . . . . . 191 (7.51)
PVB5/6 LH rotation models, face
PVB10/15 RH rotation models and PVB10/15 . . . . . . . . . . . 222 (8.75)
PVB20/29 LH and RH rotation models. PVB20/29 . . . . . . . . . . . 250 (9.84)

Vertical “Shaft-up” Installation - “S30” Drain Port


Option, for PVB5 to 29

Pump Port tapping A


type
PFB5 .562518UNF-2B 28,7 (3.85)
A
PVB5/6 .5625 18UNF-2B 19 (0.75)
PVB10/15 .7500 16UNF-2B 29,3 (1.15)
PVB20/29 .7500 16UNF-2B 38,9 (1.53)
Additional drain port

A.31
PVB5/6; PVB10/15; PVB20/29 – DIN/ISO Models

For dimensions/data not shown refer to corresponding SAE models.

PVB5/6 – Pressure Compensated Control – “C” and “CM”


44,5 (1.75)
Key: 6,0 (0.236) square
x 22,5 (0.89) long 7,24 (0.285)
22,5 (0.886)

Ø80,0
(3.15 dia)

2 holes
Ø11,3 (0.44 dia) Ø20,0
(0.787 dia)
109,0 36,0
(4.29) (1.42)

PVB10/15 – Pressure Compensated Control – “C” and “CM”


52,5 (2.07)
Key: 8,0 (0.315) square 9,24 (0.364)
x 28,0 (1.1) long
28,0 (1.1)

Ø100,0
(3.937 dia)
2 holes
Ø14,25
(0.56 dia) Ø25,0
(0.984 dia)
140 42,0 (1.65)
(5.51)

PVB20/29 – Pressure Compensated Control – “C” and “CM”


68,9 (2.71)
Key: 10,0 (0.39) square
x 35,0 (1.38) long 9,24 (0.364)
35,0 (1.38)

Ø125,0
(4.92 dia)

2 holes
Ø18,25 (0.72 dia) Ø32,0
(1.26 dia)
180,0 58,0
(7.08) (2.28)

A.32
Mass, approx. Installation Data Starting
Flange Mounting Models Horizontal mounting is resommended to Before starting, fill case with system fluid
PFB5 . . . . . . . . . . . . . . . . . . . 5 kg (11 lb) maintain necessary case fluid level. through the uppermost drain port.
PFB10 . . . . . . . . . . . . . . . . . 10 kg (22 lb) Vertical “shaft-up” installation is possible Housing must be kept full at all times to
PFB20 . . . . . . . . . . . . . . . . . 19 kg (42 lb) with pumps ordered to include the extra provide internal lubrication.When first
PVB5/6 . . . . . . . . . . . . . . . . . 8 kg (18 lb) drain port denoted by the “S30” feature; starting it may be necessary to bleed air
PVB10/15 . . . . . . . . . . . . . . 15 kg (33 lb) see “Model Code”. In all cases the drain from pump outlet to permit priming and
PVB20/29 . . . . . . . . . . . . . . 26 kg (57 lb) line must be full size, unrestricted and to reduce noise. Bleed by loosening an
PVB45 . . . . . . . . . . . . . . . 96 kg* (211 lb) connected from the uppermost drain port outlet connection until a clear stream of
PVB90s . . . . . . . . . . . . . . 104 kg (230 lb) directly to the reservoir in such a manner fluid appears. An air bleed valve,
* Also foot mounting models. that the housing remains filled with fluid. ABS-03, is available for this purpose.
 Combined foot/flange mounting
Piping of drain line must prevent
models.
siphoning. Pipe drain line so that it
Ordering Procedure
Foot Bracket Kits
terminates below fluid level. No other Before ordering, check availability with
FB-A-10 . . . . . . . . . . . . . . . . . 1,8 kg (4 lb)
lines are to be connected to this drain your Vickers reprecentative.
FB-B-10 . . . . . . . . . . . . . . . . . 2,3 kg (5 lb)
FB-C-10 . . . . . . . . . . . . . . . . 5,5 kg (12 lb) line.
Caution must be exercised to
never exceed the following unit
case pressures:
0,7 bar (10 psi) for PFB10 only.
0,35 bar (5psi) for all other models.