Вы находитесь на странице: 1из 1003

CRC No: 14733

Date: 01/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KSPHC, Mysore.

Ref No

: --

Project*

: Construction of First Floor Dormitory Recreation hall at


Carp site Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, First Floor Dormitory Block.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

8.170

Failure
Load
(kN)
655

--

8.100

570

25.33

--

8.430

600

26.67

--

8.125

755

33.55

--

8.150

720

32.00

--

8.400

750

33.33

Date of
Casting

02/02/14

Date of
Testing

30/12/14

Weight
(Kg)

Compressive
Strength (MPa)
29.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14735

Date: 01/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 30/12/14.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 2nd floor roof slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/12/14

30/12/14

8.215
8.400
8.455

Failure
Load
(kN)
335
320
280

Compressive
Strength (MPa)
14.89
14.22
12.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14732

Date: 01/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Kadtech Infraprojects Pvt Ltd, Bogadi, Mysore.

Ref No

: Letter dated 30/12/14.

Project*

: Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, F.F. Slab-49.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

718
719
720

23/12/14

30/12/14

8.555
8.600
8.525

Failure
Load
(kN)
295
300
320

Compressive
Strength (MPa)
13.11
13.33
14.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14726

Date: 31/12/14

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Incicon AG, Mandyam Hostel Building, Ramavilas Road,


Mysore.

Ref No

: --

Project*

: Mandyam Hostel Building, Ramavilas Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

28/11/14

Date of
Testing

29/12/14

7.550

Failure
Load
(kN)
320

7.350

200

8.89

7.465

330

14.67

Weight
(Kg)

Compressive
Strength (MPa)
14.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14711

Date: 31/12/14

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Arafath S.M., Bannimantap C Layout, Mysore.

Ref No

: --

Project*

: Residential site No. 22/A, Unnatinagar, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Ground floor Roof.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

15/12/14

Date of
Testing

29/12/14

7.930

Failure
Load
(kN)
390

7.860

350

15.55

8.155

360

16.00

Weight
(Kg)

Compressive
Strength (MPa)
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14712

Date: 30/12/14

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Balaji Builders, Bangalore.

Ref No

: Letter dated 28/12/14.

Project*

: Construction of 3000 MT capacity godown at Gundlupet.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

16/12/14

29/12/14

7.150
7.950
7.940

Failure
Load
(kN)
260
290
295

Compressive
Strength (MPa)
11.55
12.89
13.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14712

Date: 30/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Balaji Builders, Bangalore.

Ref No

: Letter dated 28/12/14.

Project*

: Construction of 3000 MT capacity godown at Gundlupet.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/12/14

Date of
Testing

Weight
(Kg)

29/12/14

8.105
7.960
8.100

Failure
Load
(kN)
190
170
150

Compressive
Strength (MPa)
8.44
7.55
6.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14728

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Pristine Projects Pvt Ltd, Bangalore.

Ref No

: Letter dated 29/12/14.

Project*

: Sudhabdhi Suka, JP Nagar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 25, Slab & beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/11/14

Date of
Testing

Weight
(Kg)

29/12/14

8.500
8.195
8.320

Failure
Load
(kN)
700
610
610

Compressive
Strength (MPa)
31.11
27.11
27.11

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14728

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Pristine Projects Pvt Ltd, Bangalore.

Ref No

: Letter dated 29/12/14.

Project*

: Sudhabdhi Suka, JP Nagar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 25, Slab & beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

28/11/14

29/12/14

8.200
8.220
8.200

Failure
Load
(kN)
525
535
645

Compressive
Strength (MPa)
23.33
23.78
28.67

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14728

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Pristine Projects Pvt Ltd, Bangalore.

Ref No

: Letter dated 29/12/14.

Project*

: Sudhabdhi Suka, JP Nagar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 25, Slab & beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
29/11/14

Date of
Testing

Weight
(Kg)

29/12/14

8.175
8.180
8.080

Failure
Load
(kN)
500
550
550

Compressive
Strength (MPa)
22.22
24.44
24.44

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14713

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Gopalapura to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Top Doom.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

29/11/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.125

800

35.55

8.070

790

35.11

8.080

720

32.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14714

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Danagahalli to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

--

--

--

: 150 mm x 150 mm x 150 mm


Date of
Casting

18/12/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.370

685

30.44

8.160

650

28.89

8.360

500

22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14715

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Danagahalli to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, G.L. Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

--

--

--

: 150 mm x 150 mm x 150 mm


Date of
Casting

19/12/14

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.270

740

32.89

8.700

720

32.00

8.450

770

34.22

29/12/14

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14716

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Danagahalli to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, G.L. Breace.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

20/12/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.145

725

32.22

8.400

500

22.22

8.200

710

31.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14717

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Danagahalli to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, First Lift Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

22/12/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.265

580

25.77

8.375

520

23.11

8.500

560

24.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14718

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of Pump House at Bidaragoodu to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Roof.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

27/11/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.200

780

34.67

8.075

600

26.67

8.055

810

36.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14719

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of Pump House at Bidaragoodu to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 3rd lift column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

23/11/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

7.940

770

34.22

7.815

820

36.44

7.580

790

35.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14720

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of Pump House at Bidaragoodu to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Casbel Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

22/11/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.110

630

28.00

8.090

730

32.44

8.115

690

30.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14721

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Nagarthahalli to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 3rd Lift Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

23/11/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.295

720

32.00

8.200

880

39.11

7.990

730

32.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14722

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Nagarthahalli to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 4th Lift Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

29/11/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.320

780

34.67

8.180

720

32.00

8.175

740

32.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14723

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Nagarthahalli to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, First Lift Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

15/12/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.435

620

27.55

8.760

500

22.00

8.300

570

25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14724

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Nagarthahalli to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 2nd Lift Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

18/12/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.120

780

34.67

8.700

750

33.33

8.315

820

36.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14725

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: --

Project*

: Construction of 50000 Ltr OHT at Nagarthahalli to


Providing water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 3rd Breace Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

26/11/14

Date of
Testing

29/12/14

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.350

820

36.44

8.350

760

33.78

8.370

735

32.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14748

Date: 05/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer (works), South Western Railway,


Mysore.

Ref No

: Letter No. Y/W.148/I/3401 dated 15/12/14.

Project*

: MYS-ASK section : - Elimination of manned level crossing


No. 20 @ Km. 24/200-300 and 70 @ Km. 79/400-500

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, At LC No. 70 km. 79/400-500.


RCC precast box segment.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/12/14

Date of
Testing

Weight
(Kg)

05/01/15

8.040
8.005
8.030

Failure
Load
(kN)
780
910
800

Compressive
Strength (MPa)
34.67
40.44
35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14748

Date: 05/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer (works), South Western Railway,


Mysore.

Ref No

: Letter No. Y/W.148/I/3401 dated 15/12/14.

Project*

: MYS-ASK section : - Elimination of manned level crossing


No. 20 @ Km. 24/200-300 and 70 @ Km. 79/400-500

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, At LC No. 70 km. 79/400-500.


RCC precast box segment.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

04/12/14

03/01/15

8.070

Failure
Load
(kN)
715

Compressive
Strength (MPa)
31.78

2
3

---

8.050
8.050

860
850

38.22
37.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14546

Date: 29/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer (works), South Western Railway,


Mysore.

Ref No

: Letter No. Y/W.148/I/3401 dated 15/12/14.

Project*

: MYS-ASK section : - Elimination of manned level crossing


No. 20 @ Km. 24/200-300 and 70 @ Km. 79/400-500

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, At LC No. 70 km. 79/400-500.


RCC precast box segment.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

29/11/14

27/12/14

7.970
7.910
7.960

Failure
Load
(kN)
880
800
810

Compressive
Strength (MPa)
39.11
35.56
36.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14546

Date: 29/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer (works), South Western Railway,


Mysore.

Ref No

: Letter No. Y/W.148/I/3401 dated 15/12/14.

Project*

: MYS-ASK section : - Elimination of manned level crossing


No. 20 @ Km. 24/200-300 and 70 @ Km. 79/400-500

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, At LC No. 70 km. 79/400-500.


RCC precast box segment.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm.

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/11/14

Date of
Testing

Weight
(Kg)

25/12/14

7.850
7.965
8.100

Failure
Load
(kN)
790
850
900

Compressive
Strength (MPa)
35.11
37.78
40.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14744

Date: 03/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal industrial Area, Mysore.

Ref No

: Letter dated 02/01/15.

Project*

: Damden Solarium, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 5 First Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
26/12/14

Date of
Testing

Weight
(Kg)

02/01/15

8.085
8.190
7.890

Failure
Load
(kN)
510
650
460

Compressive
Strength (MPa)
22.67
28.89
20.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14744

Date: 03/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal industrial Area, Mysore.

Ref No

: Letter dated 02/01/15.

Project*

: Damden Solarium, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Block 5 First Floor column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/12/14

Date of
Testing

Weight
(Kg)

02/01/15

8.000
8.040
8.010

Failure
Load
(kN)
795
450
550

Compressive
Strength (MPa)
35.33
20.00
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14737

Date: 01/01/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Hotel Vyshak, Mysore.

Ref No

: Letter dated 31/12/14.

Project*

: Bannimantapa, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, (RMC Cubes)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
575
566
580

1
-8.045
03/12/14
31/12/14
2
-8.170
3
-8.145
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
25.56
25.15
25.78

Testing officer

CRC No: 14738

Date: 01/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: Letter dated 31/12/14.

Project*

: Hotel Vyshak.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, RMC Concrete (Slab)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
480
517
470

1
-8.015
03/12/14
31/12/14
2
-8.090
3
-8.030
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
21.33
22.98
20.89

Testing officer

CRC No: 14736

Date: 02/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Homes, Banagatta, Pandavapura (T), Mandya (D).

Ref No

: Letter dated 31/12/14.

Project*

: Senior Homes,

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 1:2:3

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/12/14

Date of
Testing

Weight
(Kg)

31/12/14

7.485
---

Failure
Load
(kN)
350
---

Compressive
Strength (MPa)
15.56
---

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14762

Date: 07/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 05/01/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 3rd Floor Column (Site Mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/12/14

Date of
Testing

Weight
(Kg)

05/01/15

8.350
8.440
8.250

Failure
Load
(kN)
520
540
650

Compressive
Strength (MPa)
23.11
24.00
28.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14762

Date: 07/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 05/01/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 3rd Floor Column (Site Mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

27/12/14

05/01/15

8.215
8.460
8.420

Failure
Load
(kN)
365
530
450

Compressive
Strength (MPa)
16.22
23.55
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14763

Date: 07/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 05/01/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 3rd Floor Column (Site Mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

06/12/14

05/01/15

8.210
8.465
8.225

Failure
Load
(kN)
730
790
850

Compressive
Strength (MPa)
32.44
35.11
37.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14760

Date: 07/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 05/01/15.

Project*

: Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, GF Column, Club House.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
240
230
260

Compressive
Strength (MPa)

1
736
8.115
29/12/14
05/01/15
2
737
7.910
3
738
7.980
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

10.67
10.22
11.55

Testing officer

CRC No: 14759

Date: 07/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Gina Engineering Company (P) Ltd, Mysore.

Ref No

: Letter dated 05/01/15.

Project*

: Theorem Production Block-4.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Main stair case and fire stair case head room
roof concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

08/12/14

Date of
Testing

Weight
(Kg)

05/01/15

8.260
8.280
8.290
8.255
8.295
8.205

Failure
Load
(kN)
775
560
710
700
735
620

Compressive
Strength (MPa)
34.44
24.89
31.55
31.11
32.67
27.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14767

Date: 08/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, CARP, Mysore.

Ref No

: Letter dated 06/01/15.

Project*

: Construciton of CARP Office building @ CAR Ground,


Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing concrete @ CARP Site C35, C36, C41 & C42.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

30/12/14

Date of
Testing

06/01/15

7.850

Failure
Load
(kN)
300

8.150

385

17.11

7.960

340

15.11

Weight
(Kg)

Compressive
Strength (MPa)
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14772

Date: 08/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 07/01/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Gallery steps Slab 3rd Span.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1

ID No.
--

Date of
Casting
05/12/14

Date of Testing Weight (Kg)


07/01/15

8.225

Failure Load
(kN)
700

Compressive
Strength (MPa)
31.11

2
3

---

8.205
8.150

850
830

37.78
36.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14772

Date: 08/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 07/01/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Gallery steps Slab 4th Span.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/12/14

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

07/01/15

8.165
8.220
8.235

Failure
Load
(kN)
860
875
775

Compressive
Strength (MPa)
38.22
38.89
34.44

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14799

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: --

Project*

: Construction of Hotel Vyshak, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, (RMC)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
600
560
370

1
-8.030
08/12/14
10/01/15
2
-7.980
3
-8.020
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
26.67
24.89
16.44

Testing officer

CRC No: 14799

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: --

Project*

: Construction of Hotel Vyshak, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, (RMC)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
515
500
480

1
-8.355
02/01/15
10/01/15
2
-8.355
3
-8.250
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.89
22.22
21.33

Testing officer

CRC No: 14787

Date: 10/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Balaji Builders, Bangalore.

Ref No

: Letter dated 08/01/15.

Project*

: Construction of 3000 MT capacity godown at Gundlupet.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

10/12/14

08/01/15

7.830
7.930
8.060

Failure
Load
(kN)
320
300
330

Compressive
Strength (MPa)
14.22
13.33
14.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14794

Date: 10/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Harish, Gaganachumbi Road, Kuvempunagar, Mysore.

Ref No

: Letter dated 09/01/15.

Project*

: Residence @ Kuvempunagar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/12/14

10/01/15

8.445
8.200
8.355

Failure
Load
(kN)
735
610
580

Compressive
Strength (MPa)
32.67
27.11
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14798

Date: 10/01/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Damden Properties, Mysore.

Ref No

: Letter dated 09/01/15.

Project*

: Damden Solarium, Plot No. 36, 37, Ring Road,


Hebbal Industrial Area, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 3 Fifth floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
11/12/14

Date of
Testing

Weight
(Kg)

10/01/15

7.920
8.005
8.030

Failure
Load
(kN)
610
670
750

Compressive
Strength (MPa)
27.11
29.78
33.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14789

Date: 10/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 08/01/15.

Project*

: Brigade Mountain View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
460
370
430

1
37
8.250
30/12/14
08/01/15
2
38
7.985
3
39
7.865
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.44
16.44
19.11

Testing officer

CRC No: 14789

Date: 10/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 08/01/15.

Project*

: Brigade Mountain View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
340
300
350

1
49
7.765
01/01/15
08/01/15
2
50
7.730
3
53
7.665
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
15.11
13.33
15.55

Testing officer

CRC No: 14789

Date: 10/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 08/01/15.

Project*

: Brigade Mountain View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
390
415
380

1
43
7.775
31/12/14
08/01/15
2
44
7.780
3
45
7.720
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
17.33
18.44
16.89

Testing officer

CRC No: 14809

Date: 13/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Incicon AG, Mandyam Hostel Building, Ramavilas Road,


Mysore.

Ref No

: --

Project*

: Mandyam Hostel Building, Ramavilas Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Slab Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

03/01/15

Date of
Testing

12/01/15

8.320

Failure
Load
(kN)
675

8.240

580

25.78

8.315

590

26.22

Weight
(Kg)

Compressive
Strength (MPa)
30.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14808

Date: 13/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Thirumalegowda, Class I Contractor, Bangalore.

Ref No

: Letter dated 12/01/15.

Project*

: Construction of Arakere Police Station.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

15/12/14

Date of
Testing

12/01/15

7.395

Failure
Load
(kN)
90

7.290

80

3.55

7.360

100

4.44

Weight
(Kg)

Compressive
Strength (MPa)
4.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14802

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KSPHCL, Mysore.

Ref No

: Letter dated 10/01/15.

Project*

: Construction of Kitchen and Laundry at Block of PTS DAR


at Jyothinagr, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Kitchen Roof Slab & beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

13/12/14

Date of
Testing

Weight
(Kg)

10/01/15

8.310
7.985
8.430
8.095
8.515
8.365

Failure
Load
(kN)
660
350
650
665
600
675

Compressive
Strength (MPa)
29.33
15.55
28.89
29.55
26.67
30.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14792

Date: 10/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 08/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, GF Slab Club House.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

: 150 mm x 150 mm x 150 mm


Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
350
360
330

1
715
8.165
09/12/14
08/01/15
2
716
8.240
3
717
8.220
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
15.55
16.00
14.67

Testing officer

CRC No: 14792

Date: 10/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 08/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, GF Column Club House.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
ID No.
Date of
No
Casting

: 150 mm x 150 mm x 150 mm


Date of
Weight
Failure
Testing
(Kg)
Load

Compressive
Strength (MPa)

(kN)
1
747
7.640
280
31/12/14
08/01/15
2
748
7.730
315
3
749
7.585
200
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

12.44
14.00
8.879

Testing officer

CRC No: 14775

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, First Breace Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

23/12/14

Date of
Testing

08/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.385

650

28.89

8.290

590

26.22

8.485

630

28.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14776

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 2nd Lift Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

24/12/14

Date of
Testing

08/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.245

705

31.33

8.175

680

30.22

8.485

710

31.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14777

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 2nd Breace Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

25/12/14

08/01/15

8.385

620

27.55

8.320

680

30.22

8.470

620

27.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14778

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 3rd Lift Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

26/12/14

08/01/15

8.460

650

28.89

8.380

580

25.78

8.540

580

25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14779

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Nagarthalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 3rd Lift Side Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

20/12/14

08/01/15

8.100

750

33.33

7.755

600

26.67

8.100

780

34.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14780

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Nagarthalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Top Doom.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

27/12/14

08/01/15

8.120

700

31.11

8.225

670

29.78

8.040

650

28.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14783

Date: 13/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Arafath S.M., Bannimantap C Layout, Mysore.

Ref No

: Letter dated 15/01/15

Project*

: Residential site No. 22/A, Unnatinagar, Mysore-15.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Ground floor concrete slab of 22,500 mm2

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

--

--

--

16/12/14

13/01/15

8.495

530

23.55

8.450

450

20.00

8.180

450

20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14817

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Nagarthalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, First Lift Side Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

15/12/14

13/01/15

8.260

730

32.44

8.370

810

36.00

8.470

800

35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14818

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Nagarthalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Slab Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

--

--

--

09/12/14

13/01/15

8.200

850

37.78

8.215

820

36.44

8.460

790

35.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14819

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Slab Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

--

--

--

05/01/15

13/01/15

8.455

610

27.11

8.500

530

23.55

8.215

500

22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14820

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Dadadahalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

--

--

--

06/01/15

13/01/15

8.155

500

22.22

8.325

510

22.67

8.040

555

24.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14821

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Marballihundi


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

--

--

--

06/01/15

13/01/15

8.270

570

25.33

8.250

620

27.55

8.370

500

22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14824

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 14/01/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 3rd Floor Column (Site Mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

03/01/15

13/01/15

8.425
8.090
8.445

Failure
Load
(kN)
540
440
300

Compressive
Strength (MPa)
24.00
19.55
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14828

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 14/01/15.

Project*

: Shreesha Hill View (B-1), Sarkari Uthanalli Village,


Mysore Dist.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Road Culvert.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

06/01/15

14/01/15

7.855
7.745
7.540

Failure
Load
(kN)
415
330
460

Compressive
Strength (MPa)
18.44
14.67
20.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14828

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 14/01/15.

Project*

: Shreesha Hill View (B-1), Sarkari Uthanalli Village,


Mysore Dist.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Road Culvert.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/01/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

14/01/15

7.770
7.600
7.900

Failure
Load
(kN)
410
450
490

Compressive
Strength (MPa)
18.22
20.00
21.78

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14830

Date: 17/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MN Associates, KHB Colony, Kuvempunagar, Mysore.

Ref No

: Letter dated 16/01/15.

Project*

: JHBCS DHANAGALLI.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, Mix design-2.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/01/15

Date of
Testing

Weight
(Kg)

16/01/15

7.750
8.050
7.955

Failure
Load
(kN)
455
480
400

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.22
21.33
17.78

Testing officer

CRC No: 14830

Date: 17/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MN Associates, KHB Colony, Kuvempunagar, Mysore.

Ref No

: Letter dated 16/01/15.

Project*

: JHBCS DHANAGALLI.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, Mix design-1.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/01/15

16/01/15

7.805
7.850
7.855

Failure
Load
(kN)
310
300
405

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
13.78
13.33
18.00

Testing officer

CRC No: 14836

Date: 19/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MN Associates, KHB Colony, Kuvempunagar, Mysore.

Ref No

: Letter dated 17/01/15.

Project*

: JHBCS DHANAGALLI.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, Mix design-3.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

10/01/15

17/01/15

7.805
7.760
7.820

Failure
Load
(kN)
370
350
370

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.44
15.55
16.44

Testing officer

CRC No: 14833

Date: 19/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: Letter dated 17/11/15.

Project*

: Construction of Hotel Vyshak.

Source of Samples
by the Client.

: Sample Supplied

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
120
165
130

1
-7.430
10/01/15
17/01/15
2
-7.370
3
-7.545
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
5.33
7.33
5.78

3. Any correction invalidates this report.

Testing officer

CRC No: 14834

Date: 19/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal Industrial Area, Mysore.

Ref No

: Letter dated 17/01/15.

Project*

: Damden Solarium, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Block 5 Second floor column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/01/15

17/01/15

7.910
7.975
8.085

Failure
Load
(kN)
420
380
420

Compressive
Strength (MPa)
18.67
16.89
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14834

Date: 19/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal Industrial Area, Mysore.

Ref No

: Letter dated 17/01/15.

Project*

: Damden Solarium, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 4 Fifth Floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

18/12/14

17/01/15

8.155
7.895
7.950

Failure
Load
(kN)
590
700
670

Compressive
Strength (MPa)
26.22
31.11
29.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14837

Date: 19/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Incicon AG, Mandyam Hostel Building, Ramavilas Road,


Mysore.

Ref No

: Letter dated 17/01/15

Project*

: Mandyam Hostel Building, Ramavilas Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Slab Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

03/01/15

Date of
Testing

17/01/15

7.940

Failure
Load
(kN)
540

8.095

470

20.89

7.865

485

21.55

Weight
(Kg)

Compressive
Strength (MPa)
24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14839

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 19/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Column, Villa No. 49.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
570
400
500

1
771
8.000
06/01/15
19/01/15
2
772
7.945
3
773
7.955
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
25.33
17.78
22.22

Testing officer

CRC No: 14839

Date: 22/01/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 19/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, GF Stair, Club House.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
315
310
360

1
777
7.755
09/01/15
19/01/15
2
778
7.785
3
779
7.765
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
14.00
13.78
16.00

Testing officer

CRC No: 14839

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 19/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, GF Slab, Villa No. 50.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
190
195
200

1
783
7.620
11/01/15
19/01/15
2
784
7.705
3
785
7.900
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
8.44
8.67
8.89

Testing officer

CRC No: 14839

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 19/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, GF Column, Club House.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
280
300
300

1
753
7.620
02/01/15
19/01/15
2
754
7.910
3
755
7.845
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
12.44
13.33
13.33

Testing officer

CRC No: 14839

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 19/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Column, Villa No. 49.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
300
365
340

Compressive
Strength (MPa)

1
765
7.820
04/01/15
19/01/15
2
766
7.630
3
767
7.535
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

13.33
16.72
15.11

Testing officer

CRC No: 14871

Date: 22/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
350
315
405

Compressive
Strength (MPa)

1
-8.000
13/12/14
20/12/14
2
-7.990
3
-8.010
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

15.56
14.00
18.00

Testing officer

CRC No: 14871

Date: 31/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Ground Beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
360
360
350

Compressive
Strength (MPa)

1
-8.100
23/12/14
30/12/14
2
-8.120
3
-8.110
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

16.00
16.00
15.56

Testing officer

CRC No: 14871

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Plinth Beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
410
387
370

Compressive
Strength (MPa)

1
-8.050
07/01/15
14/01/15
2
-8.060
3
-8.050
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

18.22
17.20
16.44

Testing officer

CRC No: 14871

Date: 26/12/14
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C Block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


ID No.
Sl
Date of
No
Casting

: 150 mm x 150 mm x 150 mm


Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
374
405
338

Compressive
Strength (MPa)

1
-8.200
19/12/14
24/12/14
2
-8.000
3
-8.100
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

15.73
18.00
15.02

Testing officer

CRC No: 14871

Date: 06/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C Block Ground Beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
ID No.
Date of
No
Casting

: 150 mm x 150 mm x 150 mm


Date of
Weight
Failure
Testing
(Kg)
Load

Compressive
Strength (MPa)

(kN)
1
-8.025
417
29/12/14
05/01/15
2
-8.010
383
3
-8.000
383
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

18.53
17.02
17.02

Testing officer

CRC No: 14871

Date: 13/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. E Block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

05/01/15

12/01/15

8.000

Failure
Load
(kN)
338

Compressive
Strength (MPa)
15.02

2
-8.000
338
3
-7.995
390
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

15.02
17.33

Testing officer

CRC No: 14871

Date: 12/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

13/12/14

10/01/15

8.200
8.165
8.010

Failure
Load
(kN)
590
320
585

Compressive
Strength (MPa)
26.22
23.11
26.00

Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14871

Date: 21/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Ground Beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
585
500
650

1
-8.060
23/12/14
20/01/15
2
-8.085
3
-8.080
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
26.00
22.22
28.89

Testing officer

CRC No: 14871

Date: 16/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, C Block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
450
600
650

1
-8.000
19/12/14
14/01/15
2
-7.990
3
-8.010
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.00
26.67
28.88

Testing officer
CRC No: 14870

Date: 23/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 22/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Slab Villa No. 49.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
450
400
360

1
721
8.455
23/12/14
22/01/15
2
722
8.445
3
723
8.310
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.00
17.78
16.00

Testing officer

CRC No: 14870

Date: 23/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 22/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Slab Club House.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
290
270
305

1
789
8.100
14/01/15
22/01/15
2
790
8.260
3
791
8.190
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
12.89
12.00
13.55

Testing officer

CRC No: 14870

Date: 23/01/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 22/01/15.

Project*

: Construction of Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, PB Villa No. 50.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
250
280
250

1
733
7.680
26/12/14
22/01/15
2
734
7.855
3
735
7.880
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
11.11
12.44
11.11

Testing officer

CRC No: 14846

Date: 22/01/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Dadadahalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, GL Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

08/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

7.985

620

27.55

7.955

500

22.22

7.865

490

21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14847

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 2nd lift side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

09/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

7.910

650

28.89

8.130

580

25.78

8.225

600

26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14849

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, First lift column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

22/12/14

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.535

820

36.44

8.380

750

33.33

8.365

710

31.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14848

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagahalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, First lift side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

07/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.185

600

26.67

8.485

560

24.89

8.165

500

22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14850

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagahalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, GL Breace Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

20/12/14

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.350

805

35.78

8.420

770

34.22

8.300

825

36.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14851

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Danagahalli


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, GL Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

19/12/14

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

7.895

800

35.55

8.020

700

31.11

8.095

805

35.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14852

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Marballihundi


to providing Water supply to 30 enroute villages from Kabini

River as source under deposit Contribution works of RDPR.


Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, GL Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

07/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.200

550

24.44

8.155

555

24.67

8.320

480

21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14853

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Marballihundi


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, GL Breace Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

08/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.205

610

27.11

8.210

680

30.22

8.495

700

31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14854

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Marballihundi


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, First lift column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

09/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.025

610

27.11

8.120

650

28.89

8.280

550

24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14855

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Marballihundi


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, First lift Breace Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

10/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

7.910

535

23.78

7.855

580

25.78

7.685

565

25.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14856

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Marballihundi


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 2nd lift column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

11/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

7.775

500

22.22

7.745

580

25.78

8.060

530

23.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14857

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Marballihundi


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 2nd Breace Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

12/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.000

690

30.67

7.875

640

28.44

7.765

520

23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14858

Date: 22/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&D Board, Division, Mysore.

Ref No

: Letter No. Nil

Project*

: Construction of 50,000 Litres OHT at Marballihundi


to providing Water supply to 30 enroute villages from Kabini
River as source under deposit Contribution works of RDPR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 3rd lift column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

13/01/15

Date of
Testing

20/01/15

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.095

620

27.55

8.070

690

30.67

8.215

650

28.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14877

Date: 27/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal Industrial Area, Mysore.

Ref No

: Letter dated 23/01/15.

Project*

: Damden Solarium, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 5 Second floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/12/14

23/01/15

7.970
7.905
8.015

Failure
Load
(kN)
950
810
580

Compressive
Strength (MPa)
42.22
36.00
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14876

Date: 27/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 23/01/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Second floor slab. (MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

11/01/15

23/01/15

7.900
8.190
8.170

Failure
Load
(kN)
560
680
580

Compressive
Strength (MPa)
24.89
30.22
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14882

Date: 27/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Rakesh A Shah, Nazarbad, Mysore.

Ref No

: Letter dated 24/01/15.

Project*

: Construciton of Residence.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 3rd Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

11/01/15

24/01/15

8.195

Failure
Load
(kN)
450

Compressive
Strength (MPa)
20.00

2
3

---

8.205
8.075

490
450

21.78
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14881

Date: 27/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: Letter dated 24/01/15.

Project*

: Construction of Hotel Vyshak, Mysore.

Source of Samples
by the Client.

: Sample Supplied

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

17/01/15

24/01/15

7.670
7.595
8.370

Failure
Load
(kN)
230
180
755

Compressive
Strength (MPa)
10.22
8.0
33.55

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14888

Date: 29/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: Letter dated 27/01/15.

Project*

: Construction of Hotel Vyshak, Mysore.

Source of Samples
by the Client.

: Sample Supplied

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
400
450
500

1
-7.880
19/01/15
27/01/15
2
-8.010
3
-7.935
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
17.78
20.00
22.22

3. Any correction invalidates this report.

Testing officer

CRC No: 14887

Date: 28/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 27/01/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Third Floor Column (Site mix).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

27/12/14

27/01/15

8.555
8.490
8.595

Failure
Load
(kN)
810
955
770

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
36.00
42.44
34.22

Testing officer

CRC No: 14887

Date: 28/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 27/01/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Fourth Floor Column (Site mix).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

17/01/15

27/01/15

8.640
8.630
8.490

Failure
Load
(kN)
620
755
650

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
27.55
33.55
28.89

Testing officer

CRC No: 148862

Date: 23/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 21/01/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

--

21/01/15

7.690
7.775
7.860

Failure
Load
(kN)
365
360
330

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.22
16.00
14.67

Testing officer

CRC No: 14900

Date: 30/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MN Associates, KHB Colony, Kuvempunagar, Mysore.

Ref No

: Letter dated 29/01/15.

Project*

: JHBCS DHANAGALLI.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, (Mix design-4)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

22/01/15

29/01/15

7.520
7.400
7.565

Failure
Load
(kN)
320
250
300

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
14.22
11.11
13.33

Testing officer

CRC No: 14894

Date: 30/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 28/01/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, First floor corridor slab balance 50%


(+2.00 meter Level).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/12/14

Date of
Testing

Weight
(Kg)

28/01/15

8.040
8.040
8.045

Failure
Load
(kN)
795
740
700

Compressive
Strength (MPa)
35.33
32.89
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14907

Date: 31/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: Letter dated 30/01/15.

Project*

: Construction of Hotel Vyshak, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RMC Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
660
790
200

1
-8.330
02/01/15
30/01/15
2
-8.335
3
-7.600
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
29.33
35.11
8.89

Testing officer

CRC No: 14907

Date: 31/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: Letter dated 30/01/15.

Project*

: Construction of Hotel Vyshak, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column concrete

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
330
310
280

1
-7.600
23/01/15
30/01/15
2
-7.604
3
-7.834
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
14.67
13.78
12.44

Testing officer

CRC No: 14901

Date: 30/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter No. VC/MYS.LAY/INFR/TEST/2010-11

Project*

: Shreesha Hill View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 1:2:4 (Road Drains).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

31/12/14

29/01/15

8.050
7.910
8.1800

Failure
Load
(kN)
680
550
700

Compressive
Strength (MPa)
30.22
24.44
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14901

Date: 30/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter No. VC/MYS.LAY/INFR/TEST/2010-11

Project*

: Shreesha Hill View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 1:2:4 (Road Drains).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/01/15

29/01/15

7.500
7.475
7.480

Failure
Load
(kN)
180
100
100

Compressive
Strength (MPa)
8.0
4.44
4.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14914

Date: 02/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 31/01/15.

Project*

: Foundation Pruthvi at 38/C-2, situated at Industrial Suburb,


2nd Stage, Mysore South, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Third floor column (site mix).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
03/01/15

Date of
Testing

Weight
(Kg)

31/01/15

8.600
8.700
8.255

Failure
Load
(kN)
910
670
765

Compressive
Strength (MPa)
40.44
29.78
34.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14899

Date: 02/02/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 29/01/15.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020. (PG 2020/Pkg No. 33/13-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. 6 SI Block Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
380
400
390

1
-8.020
22/01/15
29/01/15
2
-8.000
3
-8.010
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.89
17.78
17.33

Testing officer

CRC No: 14871

Date: 04/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C Block Ground beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
550
600
500

Compressive
Strength (MPa)

1
-8.450
29/12/14
26/01/15
2
-8.200
3
-8.150
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

24.44
26.67
22.22

Testing officer

CRC No: 14871

Date: 04/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. E Block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
500
650
580

Compressive
Strength (MPa)

1
-8.200
05/01/15
02/02/15
2
-8.190
3
-8.180
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

22.22
28.89
25.78

Testing officer

CRC No: 14871

Date: 04/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/12/14.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Plinth Beam beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
490
530
530

Compressive
Strength (MPa)

1
-8.120
07/01/15
04/02/15
2
-8.155
3
-8.100
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

21.77
23.56
23.56

Testing officer

CRC No: 14913

Date: 02/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 31/01/15.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha

Scheme 2020. (PG-2020/PACKAGE No: 33/2013-14)


Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, C-Block Plinth beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
380
390
400

Compressive
Strength (MPa)

1
-7.985
24/01/15
31/01/15
2
-7.990
3
-8.020
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

16.89
17.33
17.78

Testing officer
CRC No: 14919

Date: 04/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 03/02/15.

Project*

: Shreesha Hill View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 1:2:4.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/01/15

03/02/15

7.655
7.315
7.120

Failure
Load
(kN)
140
120
135

Compressive
Strength (MPa)
6.22
5.33
6.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14917

Date: 04/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, Mysuru Zoo.

Ref No

: Letter No. MZA/1236/2014-15 dated 27/01/15.

Project*

: Construction of Amphitheater inside zoo gardens

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RCC waist slab towards Goral

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
06/01/15

Date of
Testing

Weight
(Kg)

03/02/15

7.570
7.380
7.645

Failure
Load
(kN)
230
440
295

Compressive
Strength (MPa)
10.22
19.55
13.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14923

Date: 06/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: L. Narayan, Site Owner, Visheshwanagar, Mysore.

Ref No

: --

Project*

: Kapali Urban Woods (Apartment), Vishweshwaranagar,


Mysore South.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting

14/01/15

Date of
Testing

Weight
(Kg)

04/02/15

8.160
8.140
8.135
7.520
8.160
8.105

Failure
Load
(kN)
580
600
590
550
565
520

Compressive
Strength (MPa)
26.00
26.67
26.22
24.44
25.11
23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14924

Date: 07/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MN Associates, KHB Colony, Kuvempunagar, Mysore.

Ref No

: Letter dated 05/01/15.

Project*

: JHBCS DHANAGALLI.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, (Mix design-1)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/01/15

05/02/15

7.850
7.920
7.870

Failure
Load
(kN)
470
450
530

Compressive
Strength (MPa)
20.89
20.00
23.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14940

Date: 07/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MN Associates, KHB Colony, Kuvempunagar, Mysore.

Ref No

: Letter dated 05/01/15.

Project*

: JHBCS DHANAGALLI.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, (Mix design-2)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

09/01/15

06/02/15

7.900
8.210
8.000

Failure
Load
(kN)
600
650
815

Compressive
Strength (MPa)
26.67
28.89
36.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14936

Date: 07/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Mukunda Prasad, Vontikoppal, Mysore.

Ref No

: Letter dated 05/02/15.

Project*

: Commercial Complex at Mukunda Prasad Site, Vontikoppal,


Mysore-02.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/01/15

05/02/15

8.020
8.150
--

Failure
Load
(kN)
400
370
--

Compressive
Strength (MPa)
17.78
16.44
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14942

Date: 07/02/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Apex Crusshers, Hirikati Village, Chamaranagar district.

Ref No

: Letter dated 06/02/15.

Project*

: Apex Crusshers.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/01/15

Date of
Testing

Weight
(Kg)

06/02/15

7.700
7.840
7.785

Failure
Load
(kN)
250
240
230

Compressive
Strength (MPa)
11.11
10.67
10.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14925

Date: 07/02/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 05/02/15.

Project*

: CA Layout.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 1:1 :3

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
28/01/15

Date of
Testing

Weight
(Kg)

05/02/15

7.955
7.735
8.100

Failure
Load
(kN)
350
250
390

Compressive
Strength (MPa)
15.55
11.11
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14927

Date: 07/02/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: M/s. Incicon AG, Mandyam Hostel Building, Ramavilas Road,


Mysore.

Ref No

: Letter dated 05/02/15.

Project*

: Mandyam Hostel Building, Ramavilas Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Slab Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

03/01/15

Date of
Testing

05/02/15

8.165

Failure
Load
(kN)
990

8.250

900

40.00

8.250

735

32.67

Weight
(Kg)

Compressive
Strength (MPa)
44.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14944

Date: 07/02/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: M/s. Jampana Constructions Pvt Ltd, Mysore.

Ref No

: Letter dated 01/02/15.

Project*

: Construction of septic tank, soak pit, & drainage slab,


2FO Quarters Package-29, Nanjangud.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, septic tank, soak pit & drainage slab, 2FO.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

25/01/15

Date of
Testing

06/02/15

7.940

Failure
Load
(kN)
395

7.650

420

18.67

7.705

390

17.33

Weight
(Kg)

Compressive
Strength (MPa)
17.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14944

Date: 07/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Jampana Constructions Pvt Ltd, Mysore.

Ref No

: Letter dated 27/01/15.

Project*

: Construction of Pts Gate Beam & Slab Package-03.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Pts Gate Beam & Slab concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

20/01/15

Date of
Testing

06/02/15

7.595

Failure
Load
(kN)
340

7.825

300

13.33

7.775

370

16.44

Weight
(Kg)

Compressive
Strength (MPa)
15.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14950

Date: 09/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Rakesh A Shah, Nazarbad Mohalla, Mysore.

Ref No

: Letter dated 07/02/15.

Project*

: Residence.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Third Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
11/01/15

Date of
Testing

Weight
(Kg)

07/02/15

8.200
8.260
8.060

Failure
Load
(kN)
890
620
770

Compressive
Strength (MPa)
39.55
27.55
34.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14949

Date: 09/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MN Associates, KHB Colony, Kuvempunagar, Mysore.

Ref No

: Letter dated 07/02/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, (Mix design-3)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
10/01/15

Date of
Testing

Weight
(Kg)

07/02/15

7.755
7.740
7.850

Failure
Load
(kN)
470
425
540

Compressive
Strength (MPa)
20.89
18.89
24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14960

Date: 11/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Shivakumar & Ganapathi Complex, Gokulam, Mysore.

Ref No

: Letter dated 09/02/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RCC Slab & Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/02/15

Date of
Testing

Weight
(Kg)

09/02/15

8.120
8.070

Failure
Load
(kN)
310
325

Compressive
Strength (MPa)
13.78
14.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14969

Date: 12/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 11/02/15.

Project*

: Construction of 78 Nos. of (72PC+6SI) Police Quarters,


Kodagu District, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 3382013-14) on Lump sum

Turnkey Basis, Based on Tenderers own Design.


Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. E block Plinth beam Conrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
420
430
400

Compressive
Strength (MPa)

1
-8.200
04/02/15
11/02/15
2
-8.220
3
-8.175
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

18.67
19.11
17.78

Testing officer

CRC No: 14973

Date: 12/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sanria Team 4 Ventures, T.K. Layout, Mysore-09.

Ref No

: Letter No. ST4/2014-15/13 dated 11/02/15.

Project*

:Apartment at Vijayanagar 1st Stage, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/02/15

11/02/15

8.150
8.180
8.170

Failure
Load
(kN)
470
485
400

Compressive
Strength (MPa)
20.89
21.55
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14968

Date: 12/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 11/02/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 3rd floor roof slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/01/15

11/02/15

8.400
8.260
8.350

Failure
Load
(kN)
650
570
560

Compressive
Strength (MPa)
28.89
25.33
24.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14959

Date: 10/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 09/02/15.

Project*

: Sri Sha Hill View Layout, Sarkari Uttanahalli village,


Varnua Hobli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/01/15

09/02/15

7.855
7.480
7.890

Failure
Load
(kN)
635
530
695

Compressive
Strength (MPa)
28.22
23.55
30.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14959

Date: 10/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 09/02/15.

Project*

: : Sri Sha Hill View Layout, Sarkari Uttanahalli village,


Varnua Hobli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3

----

: 150 mm x 150 mm x 150 mm


Date of
Casting
08/01/15

Date of
Testing

Weight
(Kg)

09/02/15

7.345
7.830
7.870

Failure
Load
(kN)
350
240
250

Compressive
Strength (MPa)
15.55
10.67
11.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14966

Date: 11/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 10/02/15.

Project*

: Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. FF Col CH.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
400
460
450

1
-7.870
22/01/15
10/01/15
2
-7.935
3
-7.970
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
17.78
20.44
20.00

Testing officer

CRC No: 14966

Date: 11/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 10/02/15.

Project*

: Brigade Palmgrove.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. FF Col CH.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
-7.900
215
29/01/15
10/01/15
2
-7.590
170
3
-7.710
225
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

9.55
7.55
10.00

Testing officer

CRC No: 14979

Date: 14/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 12/12/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Columns at South side and second floor @ SW Corner.


(MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

06/02/15

13/02/15

7.850

Failure
Load
(kN)
450

Compressive
Strength (MPa)
20.00

2
3

---

8.020
7.950

480
455

21.33
20.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14979

Date: 14/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 12/12/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Second floor slab. (MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/01/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

12/02/15

8.070
8.300
8.160

Failure
Load
(kN)
660
870
750

Compressive
Strength (MPa)
29.33
38.67
33.33

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14981

Date: 14/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: Letter dated 12/02/15

Project*

: Construction of Hotel Vyshak @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

14/01/15

12/02/15

8.020
8.070
7.965

Failure
Load
(kN)
520
510
450

Compressive
Strength (MPa)
23.11
22.67
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14982

Date: 14/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KSPHC, Mysore.

Ref No

: Letter dated 12/02/15

Project*

: CARP.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, CARP Ground F Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

04/02/15

Date of
Testing

Weight
(Kg)

12/02/15

8.305
8.295
7.985
8.010
8.170
8.085

Failure
Load
(kN)
740
670
600
575
500
690

Compressive
Strength (MPa)
32.89
29.78
26.67
25.55
22.22
30.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14982

Date: 14/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KSPHC, Mysore.

Ref No

: Letter dated 12/02/15

Project*

: CARP.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, CARP Ground F Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

04/02/15

Date of
Testing

Weight
(Kg)

12/02/15

8.000
8.060
8.185
8.120
8.140
8.105

Failure
Load
(kN)
600
660
520
650
665
800

Compressive
Strength (MPa)
26.67
29.33
23.11
28.89
29.55
35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14982

Date: 14/02/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Executive Engineer, KSPHC, Mysore.

Ref No

: Letter dated 12/02/15

Project*

: CARP.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, CARP Ground F Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm


Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

8.215

660

29.33

04/02/15
12/02/15
2
-8.335
660
3
-8.375
650
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

29.33
28.89

Sl
No

ID No.

--

Date of
Casting

Date of
Testing

Testing officer

CRC No: 14920

Date: 06/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 04/02/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. E block Ground beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
350
390
360

1
-8.295
28/01/15
04/02/15
2
-8.360
3
-8.300
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
15.56
17.33
16.00

Testing officer

CRC No: 14992

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. RAL Constructions, Mysore.

Ref No

: Letter dated 14/02/15.

Project*

: Thandya Project Site Nanjangud, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
770
845
900
600
850
950

1
-8.120
2
-8.185
3
-8.100
27/12/14
14/02/15
4
-8.110
5
-8.100
6
-8.225
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
34.22
37.55
40.00
26.67
37.78
42.22

Testing officer

CRC No: 14992

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. RAL Constructions, Mysore.

Ref No

: Letter dated 14/02/15.

Project*

: Thandya Project Site Nanjangud, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
940
900
960
750
900
845

1
-8.100
2
-8.320
3
-7.995
24/01/15
14/02/15
4
-8.060
5
-8.100
6
-8.055
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
41.78
40.00
42.67
33.33
40.00
37.56

Testing officer

CRC No: 14992

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. RAL Constructions, Mysore.

Ref No

: Letter dated 14/02/15.

Project*

: Thandya Project Site Nanjangud, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
860
600
780
810
760
650

1
-8.700
2
-8.350
3
-8.060
08/01/15
14/02/15
4
-7.955
5
-8.075
6
-7.970
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
38.22
26.67
34.67
36.00
33.78
28.89

Testing officer

CRC No: 14992

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. RAL Constructions, Mysore.

Ref No

: Letter dated 14/02/15.

Project*

: Thandya Project Site Nanjangud, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
580
670
770

1
-7.900
05/02/15
14/02/15
2
-8.380
3
-8.200
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
25.78
29.78
34.22

Testing officer

CRC No: 14986

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 13/02/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 3rd Floor Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/02/15

12/02/15

8.070
8.135
8.050

Failure
Load
(kN)
445
455
420

Compressive
Strength (MPa)
19.78
20.22
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14994

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 10/02/15.

Project*

: Construction of Brigade Mountain View, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Column concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

100
101
102

Date of
Casting
11/01/15

Date of
Testing

Weight
(Kg)

10/02/15

7.930
8.100
7.940

Failure
Load
(kN)
400
690
780

Compressive
Strength (MPa)
17.78
30.67
34.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14994

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 10/02/15.

Project*

: Construction of Brigade Mountain View, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing concrete D block.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

235
236
237

31/01/15

10/02/15

7.725
7.640
7.800

270
330
420

12.00
14.67
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14994

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 10/02/15.

Project*

: Construction of Brigade Mountain View, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Column Concrete D Block.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

223
224
225

Date of
Casting
30/01/15

Date of
Testing

Weight
(Kg)

10/02/15

7.900
7.690
7.810

Failure
Load
(kN)
390
390
400

Compressive
Strength (MPa)
17.33
17.33
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14994

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 10/02/15.

Project*

: Construction of Brigade Mountain View, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing C & D Block.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

213
214
215

Date of
Casting
25/01/15

Date of
Testing

Weight
(Kg)

10/02/15

7.760
7.850
7.675

Failure
Load
(kN)
370
435
330

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.44
19.33
14.67

Testing officer

CRC No: 14994

Date: 16/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Kadtech Infraprojects Pvt Ltd, Mysore.

Ref No

: Letter dated 10/02/15.

Project*

: Construction of Brigade Mountain View, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing Concrete C Block.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

217
218
219

Date of
Casting
30/01/15

Date of
Testing

Weight
(Kg)

10/02/15

7.800
7.735
7.865

Failure
Load
(kN)
360
420
420

Compressive
Strength (MPa)
16.00
18.67
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14999

Date: 18/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 16/02/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 4th Floor Columns (Site mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/02/15

Date of
Testing

Weight
(Kg)

16/02/15

8.615
8.380
8.230

Failure
Load
(kN)
400
305
250

Compressive
Strength (MPa)
17.78
13.55
11.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14997

Date: 18/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 16/02/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C Block Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
350
375
390

1
-8.005
09/02/15
16/02/15
2
-8.200
3
-8.100
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
15.55
16.67
17.33

Testing officer

CRC No: 14997

Date: 18/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 16/02/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
400
380
370

1
-8.210
09/02/15
16/02/15
2
-8.050
3
-8.120
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
17.78
16.89
16.44

Testing officer

CRC No: 14997

Date: 18/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 16/02/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. 6 SI Block Ground Beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
400
360
380

1
-8.120
09/02/15
16/02/15
2
-8.435
3
-8.100
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
17.78
16.00
16.89

Testing officer

CRC No: 14901

Date: 19/02/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 18/02/15.

Project*

: Shreesha Hill View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/02/15

Date of
Testing

Weight
(Kg)

18/02/15

8.115
8.330
7.760

Failure
Load
(kN)
535
550
450

Compressive
Strength (MPa)
23.78
24.44
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14901

Date: 19/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 18/02/15.

Project*

: Shreesha Hill View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/02/15

18/02/15

7.475
8.465
8.060

Failure
Load
(kN)
340
345
650

Compressive
Strength (MPa)
15.11
15.33
28.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15007

Date: 21/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 19/02/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
10/01/15

Date of
Testing

Weight
(Kg)

20/02/15

7.620
7.910
7.615

Failure
Load
(kN)
270
260
230

Compressive
Strength (MPa)
12.00
11.56
10.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15007

Date: 21/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 19/02/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

14/01/15

20/02/15

7.710
8.130
7.970

Failure
Load
(kN)
815
705
700

Compressive
Strength (MPa)
36.22
31.33
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15009

Date: 20/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 19/02/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 4th Floor Column (Site Mix).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

19/01/15

19/02/15

8.585
8.520
8.340

Failure
Load
(kN)
650
720
600

Compressive
Strength (MPa)
28.89
32.00
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15003

Date: 18/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 01/02/15.

Project*

: Construction of Sub way @ Mysore Railway station, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
12/01/15

Date of
Testing

Weight
(Kg)

02/02/15

8.024
8.100
8.000

Failure
Load
(kN)
1000
1020
1000

Compressive
Strength (MPa)
44.44
45.33
44.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15015

Date: 21/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Jampana Constructions Pvt Ltd, Mysore.

Ref No

: Letter dated 18/02/15.

Project*

: Construction of PTS gate beam & slab under package-03 @


Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, PTS Gate & Slab Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

20/01/15

Date of
Testing

20/02/15

8.010

Failure
Load
(kN)
660

8.260

900

40.33

8.040

730

32.44

Weight
(Kg)

Compressive
Strength (MPa)
29.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15005

Date: 21/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 19/02/15.

Project*

: Shreesha Hill View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 1:2:4, Road drains.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
22/01/15

Date of
Testing

Weight
(Kg)

19/02/15

8.225
8.315
7.985

Failure
Load
(kN)
650
550
570

Compressive
Strength (MPa)
28.89
24.44
25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15005

Date: 21/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 19/02/15.

Project*

: Shreesha Hill View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 1:1 :3, Road culverts.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
12/02/15

Date of
Testing

Weight
(Kg)

19/02/15

7.780
8.350
8.160

Failure
Load
(kN)
330
300
270

Compressive
Strength (MPa)
14.67
13.33
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14899

Date: 23/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 29/01/15.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha

Scheme 2020. (PG 2020/Pkg No. 33/13-14)


Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. 6 SI Block Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
560
600
580

Compressive
Strength (MPa)

1
-8.220
22/01/15
19/02/15
2
-8.375
3
-8.170
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

24.89
26.67
25.78

Testing officer

CRC No: 14913

Date: 23/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPHCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 31/01/15.

Project*

: Construction of 78 No.s of (72PC-6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020. (PG-2020/PACKAGE No: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, C-Block Plinth beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
500
550
550

Compressive
Strength (MPa)

1
-8.510
24/01/15
21/02/15
2
-8.250
3
-8.175
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

22.22
24.44
24.44

Testing officer

CRC No: 14920

Date: 25/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 04/02/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. E block Ground beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
740
670
690

Compressive
Strength (MPa)

1
-8.200
28/01/15
25/02/15
2
-8.140
3
-8.185
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

32.89
29.78
30.67

Testing officer

CRC No: 15024

Date: 25/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Jampana Constructions Pvt Ltd, Mysore.

Ref No

: Letter dated 22/02/15.

Project*

: Construction of soak pit, Septic tank, Drainage plinth beam


& Slab at Nanjangudu, Under Package-29 at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, soak pit, Septic tank, Drainage plinth beam & Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004).

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

25/01/15

Date of
Testing

23/02/15

8.170

Failure
Load
(kN)
1000

8.110

1040

46.22

7.920

820

36.44

Weight
(Kg)

Compressive
Strength (MPa)
44.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15045

Date: 28/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Jayaprakash, Kuvempunagar, Mysore.

Ref No

: Letter dated 26/02/15.

Project*

: Residence.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004).

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

12/02/15

26/02/15

8.135

670

29.78

8.085

710

31.55

8.200

550

24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15056

Date: 28/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Karnataka Ready Mix Concrete, Mysore.

Ref No

: Letter dated 27/02/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004).

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

--

--

--

29/01/15

27/02/15

8.450

880

39.11

8.150

950

42.22

8.380

800

35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15056

Date: 28/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Karnataka Ready Mix Concrete, Mysore.

Ref No

: Letter dated 27/02/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004).

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

29/01/15

27/02/15

8.250

Failure
Load
(kN)
1000

Compressive
Strength (MPa)
44.44

--

8.220

1050

46.67

--

8.260

1020

45.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15053

Date: 28/02/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 26/02/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, first floor corroder slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/02/15

Date of
Testing

Weight
(Kg)

26/02/15

8.010
8.020
8.170

Failure
Load
(kN)
550
470
570

Compressive
Strength (MPa)
24.44
20.89
25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15041

Date: 27/02/1
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/02/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. F Block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
18/02/15

Date of
Testing

Weight
(Kg)

25/02/15

8.215
8.260
8.170

Failure
Load
(kN)
400
420
420

Compressive
Strength (MPa)
17.78
18.67
18.67

Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15061

Date: 02/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Ess & ESS Infrastructure Pvt Ltd.

Ref No

: --

Project*

: J.S.S. Residential Layout, Varuna, T.N. Pura Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. S.T.P. Raft concrte.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
350
380
300
380
330
400

1
-7.900
2
-8.110
3
-8.170
16/01/15
28/02/15
4
-7.970
5
-8.000
6
-8.090
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
15.55
16.89
13.33
16.89
14.67
17.78

Testing officer

CRC No: 15058

Date: 02/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Apex Crusshers, Hirikati Village, Chamaranagar district.

Ref No

: Letter dated 27/02/15.

Project*

: Apex Crusshers.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/01/15

Date of
Testing

Weight
(Kg)

27/02/15

7.835
7.870
8.020

Failure
Load
(kN)
480
400
490

Compressive
Strength (MPa)
21.33
17.78
21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15040


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Assistan Executive Engineer, RD&PR Sub division,


Chamarajanagar.

Ref No

: Letter dated 27/09/14.

Project*

: Improvement of road from Lakkur to Kabbahalli,


Gundlupet Taluk (Job No. KN-08-04).

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6
7
8

---------

Date of
Casting

--

Date of
Testing

Weight
(Kg)

25/02/15

7.690
8.010
8.060
8.260
8.095
8.140
8.090
7.920

Failure
Load
(kN)
940
800
820
980
780
1000
890
950

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
41.78
35.55
36.44
43.55
34.67
44.44
39.55
42.22

Testing officer

CRC No: 14969

Date: 05/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 11/02/15.

Project*

: Construction of 78 Nos. of (72PC+6SI) Police Quarters,


Kodagu District, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 3382013-14) on Lump sum
Turnkey Basis, Based on Tenderers own Design.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. E block Plinth beam Conrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
650
700
675

1
-8.315
04/02/15
04/03/15
2
-8.315
3
-8.210
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
28.89
31.11
30.00

Testing officer

CRC No: 15069

Date: 04/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Lakshmi, # 1100, Devaparthiva Road,


Chamarajapuram, Mysore.

Ref No

: Letter dated 02/03/2015.

Project*

: Residential Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25 (RMC).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

23/02/15

02/03/15

8.135
8.145
--

Failure
Load
(kN)
440
350
--

Compressive
Strength (MPa)
19.55
15.55
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15074

Date: 05/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Prestine Projects (P) Ltd, Bangalore.

Ref No

: Letter dated 03/02/2015.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25 Slab & Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/02/15

Date of
Testing

Weight
(Kg)

03/03/15

8.180
8.115
8.140

Failure
Load
(kN)
320
250
280

Compressive
Strength (MPa)
14.22
11.11
12.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15070

Date: 05/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KSPHC, Mysore.

Ref No

: --

Project*

: CARP

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Column concrete C22, C24, C1-C2, C5.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/02/15

Date of
Testing

Weight
(Kg)

03/03/15

7.735
7.600
7.630

Failure
Load
(kN)
270
250
320

Compressive
Strength (MPa)
12.00
11.11
14.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15070

Date: 05/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KSPHC, Mysore.

Ref No

: --

Project*

: CARP

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, C6, C23, C7,C23, C3, C4.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/02/15

Date of
Testing

Weight
(Kg)

04/03/15

7.730
7.615
7.660

Failure
Load
(kN)
280
230
350

Compressive
Strength (MPa)
12.44
10.22
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15070

Date: 05/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KSPHC, Mysore.

Ref No

: --

Project*

: CARP

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, GF roof concrete CARP Site.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6
7
8
9

----------

Date of
Casting

04/02/15

Date of
Testing

Weight
(Kg)

04/03/15

8.130
8.320
8.000
8.170
8.140
8.225
8.230
8.015
8.040

Failure
Load
(kN)
770
620
555
760
550
825
550
690
730

Compressive
Strength (MPa)
34.22
27.55
24.67
33.78
24.44
36.67
24.44
30.67
32.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15070

Date: 05/03/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Executive Engineer, KSPHC, Mysore.

Ref No

: --

Project*

: CARP

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: GF roof concrete CARP Site.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

04/02/15

Date of
Testing

Weight
(Kg)

04/03/15

8.000
8.180
7.980
8.410
8.335
8.330

Failure
Load
(kN)
730
670
800
810
730
780

Compressive
Strength (MPa)
32.44
29.78
35.55
36.00
32.44
34.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15080

Date: 06/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 04/03/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 4th Floor Roof Slab (RMC)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/02/15

Date of
Testing

Weight
(Kg)

04/03/15

8.000
8.080
8.075

Failure
Load
(kN)
250
290
250

Compressive
Strength (MPa)
11.11
12.89
11.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15078

Date: 06/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Rakesh A Shah, Nazarbad, Mysore.

Ref No

: Letter dated 04/03/15.

Project*

: Residence.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/02/15

04/03/15

7.960
8.140
8.090

Failure
Load
(kN)
480
530
550

Compressive
Strength (MPa)
21.33
23.55
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15081

Date: 06/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sanria Team 4 Ventures, T.K. Layout, Mysore-09.

Ref No

: Letter No. ST4/2014-15/14 dated 04/03/15.

Project*

: Apartment at Vijayanagar 1st Stage, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/02/15

04/03/15

8.240
8.250
8.140

Failure
Load
(kN)
735
690
585

Compressive
Strength (MPa)
32.67
30.67
26.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15079

Date: 06/03/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 04/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Slab Concrete. Ground Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
300
325
270

1
-7.400
25/02/15
04/03/15
2
-7.385
3
-7.290
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
13.33
14.44
12.00

Testing officer

CRC No: 15099

Date: 09/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 07/03/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 3rd Floor Roof Slab (RMC).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/02/15

07/03/15

8.505
8.510
8.525

Failure
Load
(kN)
510
560
490

Compressive
Strength (MPa)
22.67
24.89
21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15089

Date: 09/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: Letter dated 06/03/15.

Project*

: Construction of Hotel Vyshak @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

26/02/15

Date of
Testing

Weight
(Kg)

06/03/15

7.935
7.960
8.000
7.800
7.880
8.015

Failure
Load
(kN)
300
530
350
410
390
460

Compressive
Strength (MPa)
13.33
23.55
15.55
18.22
17.33
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15106

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. S.Subramanyan Construction Co. (P) Ltd.

Ref No

: Letter dated 09/03/15.

Project*

: C/o. M/s. Triveni Engineering & Industries Ltd, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing Raft (RMC).

Technical Reference
1959 (Reaffirmed 2004)

: IS 516

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/03/15

09/03/15

8.035
7.875
8.125

Failure
Load
(kN)
360
450
550

Compressive
Strength (MPa)
16.00
20.00
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15106

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. S.Subramanyan Construction Co. (P) Ltd.

Ref No

: Letter dated 09/03/15.

Project*

: C/o. M/s. Triveni Engineering & Industries Ltd, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RCC Wall Raft (RCC)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)


: 22500 mm2

C/S Area of the specimen


Size of the Specimen
Sl
No

ID No.

4
5
6

----

: 150 mm x 150 mm x 150 mm


Date of
Casting
02/03/15

Date of
Testing

Weight
(Kg)

09/03/15

7.925
7.915
7.990

Failure
Load
(kN)
785
550
580

Compressive
Strength (MPa)
34.89
24.44
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15102

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Mysore.

Ref No

: --

Project*

: Construction of Hotel Vyshak @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab (RMC).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
28/02/15

Date of
Testing

Weight
(Kg)

09/03/15

8.255
8.260
8.220

Failure
Load
(kN)
730
665
640

Compressive
Strength (MPa)
32.44
29.55
28.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14997

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 16/02/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C Block Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
600
630
610

Compressive
Strength (MPa)

1
-8.380
09/02/15
10/03/15
2
-8.170
3
-8.200
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

26.67
28.00
27.11

Testing officer

CRC No: 14997

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 16/02/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
500
510
600

Compressive
Strength (MPa)

1
-8.250
09/02/15
10/03/15
2
-8.385
3
-8.190
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

22.22
22.67
26.67

Testing officer

CRC No: 14997

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 16/02/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. 6 SI Block Ground Beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
605
600
600

1
-8.235
09/02/15
10/03/15
2
-8.190
3
-8.215
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
26.89
26.67
26.67

Testing officer

CRC No: 15110

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 10/03/15.

Project*

: SDM College, JLB Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Pile.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

27/02/15

10/03/15

7.660
7.580
7.625

Failure
Load
(kN)
470
420
375

Compressive
Strength (MPa)
20.89
18.67
16.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15111

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. RAL Constructions, Mysore.

Ref No

: Letter dated 10/03/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
-8.325
480
07/03/15
10/03/15
2
-8.205
470
3
-8.140
595
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

21.33
20.89
26.44

Testing officer

CRC No: 15111

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. RAL Constructions, Mysore.

Ref No

: Letter dated 10/03/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

05/02/15

10/03/15

7.250
7.160

Failure
Load
(kN)
790
590

Compressive
Strength (MPa)
35.11
26.22

3
-7.390
910
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

40.44

Testing officer

CRC No: 15113

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sanria Team 4 Ventures, T.K. Layout, Mysore-09.

Ref No

: Letter No. ST4/2014-15/16 dated 11/03/15.

Project*

: Apartment at Vijayanagar 1st Stage, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/03/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

11/03/15

8.015
8.070
8.175

Failure
Load
(kN)
300
345
380

Compressive
Strength (MPa)
13.33
15.83
16.89

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15114

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 11/03/15.

Project*

: Shreesha Hill View Layout, Sarkari Uthanalli Village,


Varuna, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Road Culvert.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/02/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

11/03/15

7.540
8.115
8.345

Failure
Load
(kN)
320
610
580

Compressive
Strength (MPa)
14.22
27.11
25.78

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15114

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 11/03/15.

Project*

: Shreesha Hill View Layout, Sarkari Uthanalli Village,


Varuna, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Road Culvert.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/02/15

11/03/15

7.960
8.115
7.845

Failure
Load
(kN)
650
380
810

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
28.89
16.89
36.00

3. Any correction invalidates this report.

Testing officer

CRC No: 15122

Date: 13/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: --

Project*

: Subway construction of SWR.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/02/15

12/03/15

8.090
8.140
8.160

Failure
Load
(kN)
1040
1000
880

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
46.22
44.44
39.11

Testing officer

CRC No: 15116

Date: 13/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Rakesh A Shah, Nazarbad, Mysore.

Ref No

: Letter dated 12/03/15.

Project*

: Construction of Residence & Showroom.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
26/02/15

Date of
Testing

Weight
(Kg)

12/03/15

8.115
8.090
8.105

Failure
Load
(kN)
550
570
620

Compressive
Strength (MPa)
24.44
25.33
27.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15117

Date: 13/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 12/03/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, LMB Bottom Column (Site Mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/03/15

Date of
Testing

Weight
(Kg)

12/03/15

8.025
8.330
8.290

Failure
Load
(kN)
240
340
300

Compressive
Strength (MPa)
10.67
15.11
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15124

Date: 13/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 12/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. B block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
360
410
350

1
-7.320
05/03/15
12/03/15
2
-7.395
3
-7.310
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.00
18.22
15.56

Testing officer

CRC No: 15129

Date: 16/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 13/03/15

Project*

: Construction of CARP Site @ CAR Ground, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, First Flour Column Concrete at CARP.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

06/03/15

Date of
Testing

13/03/15

7.890

Failure
Load
(kN)
260

8.050

245

10.89

7.800

250

11.11

Weight
(Kg)

Compressive
Strength (MPa)
11.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15129

Date: 16/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 13/03/15

Project*

: Construction of CARP Site @ CAR Ground, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, First Flour Column Concrete at CARP.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

07/03/15

Date of
Testing

14/03/15

7.250

Failure
Load
(kN)
230

7.350

190

8.44

7.400

200

8.89

Weight
(Kg)

Compressive
Strength (MPa)
10.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15128

Date: 16/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Shaik Mohiuddin Arafath, Bannimantap C Layout, Mysore.

Ref No

: Letter dated 13/03/15.

Project*

: Residential site No. 22/A, Unnatinagar, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, First Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

14/03/15

Date of
Testing

13/03/15

8.070

Failure
Load
(kN)
570

8.355

590

26.22

8.110

645

28.67

Weight
(Kg)

Compressive
Strength (MPa)
25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15136

Date: 17/03/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter dated 13/03/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No: 1 4.0 X 4.15 m I/I.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

06/03/15

Date of
Testing

16/03/15

8.135

Failure
Load
(kN)
740

8.035

695

30.89

8.005

700

31.11

Weight
(Kg)

Compressive
Strength (MPa)
32.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15136

Date: 17/03/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter dated 13/03/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No: 2 4.0 X 4.15 m I/I.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

08/03/15

Date of
Testing

16/03/15

8.090

Failure
Load
(kN)
600

8.030

750

33.33

7.900

600

26.67

Weight
(Kg)

Compressive
Strength (MPa)
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15153

Date: 18/03/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 16/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C block Slab Concrete (G.F)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
500
480
450

1
-7.685
09/03/15
16/03/15
2
-7.870
3
-7.625
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.22
21.33
20.00

Testing officer

CRC No: 15145

Date: 18/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 13/03/15

Project*

: Construction of CAR Building @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Column Concrete at CARP.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

11/03/15

Date of
Testing

17/03/15

7.410

Failure
Load
(kN)
200

7.470

150

6.67

7.735

175

7.78

Weight
(Kg)

Compressive
Strength (MPa)
8.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15145

Date: 18/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 13/03/15

Project*

: Construction of CAR Building @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Column Concrete at CARP.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

12/03/15

Date of
Testing

17/03/15

7.450

Failure
Load
(kN)
330

7.445

300

13.33

7.465

380

16.89

Weight
(Kg)

Compressive
Strength (MPa)
14.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15149

Date: 18/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 17/03/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, First floor corridor slab (Balance 30%)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
18/02/15

Date of
Testing

Weight
(Kg)

18/03/15

7.980
8.150
8.045

Failure
Load
(kN)
780
800
800

Compressive
Strength (MPa)
34.57
35.55
35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15167

Date: 20/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KHB Sub division, Mysuru.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/03/15

Project*

: Construction of RTO Office, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
350
360
360

Compressive
Strength (MPa)

1
-7.760
13/03/15
20/03/15
2
-7.700
3
-7.805
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

15.56
16.00
16.00

Testing officer

CRC No: 15152

Date: 20/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 18/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. F- Block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
760
785
650

Compressive
Strength (MPa)

1
-8.400
18/02/15
17/03/15
2
-8.200
3
-8.100
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

33.78
34.89
28.89

Testing officer

CRC No: 15108

Date: 11/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 18/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D- Block column concrete (First Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
270
240
210

1
-7.235
02/03/15
09/03/15
2
-7.350
3
-7.350
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
12.00
10.67
11.11

Testing officer

CRC No: 15162

Date: 20/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. S.Subramanyan Construction Co. (P) Ltd,


C/o. M/s. Triveni Engineering & Industries Ltd, Mysore.

Ref No

: Letter dated 19/03/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, New Assemby by pedestal with Bolt, E7, E8, E9


& E10.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/03/15

19/03/15

8.230
8.130
8.275

Failure
Load
(kN)
600
560
660

Compressive
Strength (MPa)
26.67
24.89
29.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15172

Date: 25/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: --

Project*

: Subway to Mysore Railway Station.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

23/02/15

23/03/15

8.050

Failure
Load
(kN)
820

Compressive
Strength (MPa)
36.44

2
3

---

8.185
7.995

930
980

41.33
43.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15166

Date: 24/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D-Block Slab Concrete (First Floor).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
-8.330
500
13/03/15
20/03/15
2
-8.105
555
3
-8.295
410
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

22.22
24.67
18.22

Testing officer

CRC No: 15166

Date: 24/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. B-Block Ground beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

14/03/15

21/03/15

8.245
8.220

Failure
Load
(kN)
385
495

Compressive
Strength (MPa)
17.11
22.00

3
-8.400
380
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

16.89

Testing officer
CRC No: 15166

Date: 24/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D-Block column concrete (2nd Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-15/03/15
22/03/15
2
-3
-Note:
1.* Informatin furnished by the client.

Weight
(Kg)
8.425
8.375
8.390

Failure
Load
(kN)
360
300
335

Compressive
Strength (MPa)
16.00
13.33
14.89

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer
CRC No: 15156

Date: 25/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, KSRTC, Puttur Division,


Puttur.

Ref No

: Your letter No. KST/PD/AEE/727/14-15 dated 12/03/15.

Project*

: Improvement work at KSRTC Bus Stand, Dharmastala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

18/02/15

18/03/15

8.002
8.100
7.955

Failure
Load
(kN)
500
520
560

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.22
23.11
24.89

Testing officer

CRC No: 15187

Date: 26/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Mr. Shivakumar & KB Ganapathi, Gokulam, Mysore-23.

Ref No

: Your letter dated 25/03/15.

Project*

: Commercial Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
18/03/15

Date of
Testing

Weight
(Kg)

25/03/15

8.290
8.315
--

Failure
Load
(kN)
360
365
--

Compressive
Strength (MPa)
16.00
16.22
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15173

Date: 25/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 23/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C-Block Slab Concrete (First Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
400
510
500

1
-8.745
16/03/15
23/03/15
2
-8.585
3
-8.260
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
17.78
22.67
22.22

Testing officer

CRC No: 15173

Date: 25/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 23/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. F-Block Plinth Beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
420
400
510

1
-8.335
16/03/15
23/03/15
2
-8.470
3
-8.495
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
18.67
17.78
22.67

Testing officer
CRC No: 15136

Date: 17/03/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter dated 13/03/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No: 2 4.0 X 4.15 m I/I.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

08/03/15

Date of
Testing

16/03/15

8.090

Failure
Load
(kN)
600

8.030

750

33.33

7.900

600

26.67

Weight
(Kg)

Compressive
Strength (MPa)
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15171

Date: 25/03/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. SSE/W/(O)/MYS dated 20/03/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Casted during the concreting (pre cost) the sub-way


segments of size 4.0mX4.0m (I/I) at the Lc: 20 @ km 24/200300 MYS-ASK Section.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
2

LC-20
Seg-4

16/03/15

23/03/15

8.170

Failure
Load
(kN)
800

8.200

875

38.89

8.105

788

35.00

Weight
(Kg)

Compressive
Strength (MPa)
35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15171

Date: 25/03/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. SSE/W/(O)/MYS dated 20/03/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Casted during the concreting (pre cost) the sub-way


segments of size 4.0mX4.0m (I/I) at the Lc: 20 @ km 24/200300 MYS-ASK Section.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
2

LC-20
Seg-3

15/03/15

23/03/15

8.245

Failure
Load
(kN)
820

8.090

833

37.00

8.330

850

37.78

Weight
(Kg)

Compressive
Strength (MPa)
36.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15189

Date: 27/03/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C-Block Column Concrete (2nd Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
350
410
320

1
-7.980
18/03/15
25/03/15
2
-8.135
3
-8.080
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
15.55
18.22
14.22

Testing officer
CRC No: 15200

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 27/03/15.

Project*

: Subway in Mysore Railway Station.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
28/02/15

Date of
Testing

Weight
(Kg)

27/03/15

8.130
8.120
8.085

Failure
Load
(kN)
1000
900
960

Compressive
Strength (MPa)
44.44
40.00
42.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15199

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 27/03/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 4th Floor Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

19/03/15

27/03/15

8.240
8.350
8.250

Failure
Load
(kN)
520
450
400

Compressive
Strength (MPa)
23.11
20.00
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15201

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Mysore.

Ref No

: Letter dated 27/03/15.

Project*

: Damden Solarium, Hebbal Industrial Area, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 5 fourth floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/02/15

Date of
Testing

Weight
(Kg)

27/03/15

7.895
8.045
7.960

Failure
Load
(kN)
440
380
340

Compressive
Strength (MPa)
19.55
16.89
15.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15201

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Mysore.

Ref No

: Letter dated 27/03/15.

Project*

: Damden Solarium, Hebbal Industrial Area, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 4 Sixth floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/02/15

Date of
Testing

Weight
(Kg)

27/03/15

7.900
7.930
8.060

Failure
Load
(kN)
395
480
285

Compressive
Strength (MPa)
17.55
21.33
12.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15192

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. SSE/W/ (O)/MYS dated 22/03/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Casted during the concreting (pre cost) the sub-way


segments of size 4.0mX4.15m (I/I) at the Lc. No 20 @ km
24/200-300 MYS-ASK Section.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.
RUB
Segment
No. 5

Date of
Casting

17/03/15

Date of
Testing

26/03/15

8.275

Failure
Load
(kN)
800

7.995

730

32.44

8.035

780

34.67

Weight
(Kg)

Compressive
Strength (MPa)
35.56

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15192

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. SSE/W/ (O)/MYS dated 22/03/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Casted during the concreting (pre cost) the sub-way

segments of size 4.0mX4.15m (I/I) at the Lc. No 20 @ km


24/200-300 MYS-ASK Section.
Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.
RUB
Segment
No. 6

Date of
Casting

19/03/15

Date of
Testing

26/03/15

7.875

Failure
Load
(kN)
630

7.850

600

26.67

8.090

650

28.89

Weight
(Kg)

Compressive
Strength (MPa)
28.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15192

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. SSE/W/ (O)/MYS dated 22/03/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Casted during the concreting (pre cost) the sub-way


segments of size 4.0mX4.15m (I/I) at the Lc. No 20 @ km

24/200-300 MYS-ASK Section.


Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.
RUB
Segment
No. 7

Date of
Casting

20/03/15

Date of
Testing

26/03/15

7.925

Failure
Load
(kN)
635

7.950

660

29.33

8.015

600

26.67

Weight
(Kg)

Compressive
Strength (MPa)
28.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15192

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. SSE/W/ (O)/MYS dated 22/03/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Casted during the concreting (pre cost) the sub-way


segments of size 4.0mX4.15m (I/I) at the Lc. No 20 @ km
24/200-300 MYS-ASK Section.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.
RUB
Segment
No. 7

Date of
Casting

21/03/15

Date of
Testing

28/03/15

7.900

Failure
Load
(kN)
730

7.830

750

33.33

7.775

780

34.67

Weight
(Kg)

Compressive
Strength (MPa)
32.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15203

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. SSE/W/MYS/ dated 25/03/15.

Project*

: Abutment & Return walls, Mysore-Arsikere Section,


Elimination of Manned level crossing No: 15 @ km
17/800-900 by construction of ROB.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 3rd lift.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

14/03/15

Date of
Testing

28/03/15

7.920

Failure
Load
(kN)
500

7.940

520

23.11

7.940

490

21.78

Weight
(Kg)

Compressive
Strength (MPa)
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15203

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. SSE/W/MYS/ dated 25/03/15.

Project*

: Abutment & Return walls, Mysore-Arsikere Section,


Elimination of Manned level crossing No: 15 @ km
17/800-900 by construction of ROB.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 4th lift.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

: 150 mm x 150 mm x 150 mm


Date of
Casting

16/03/15

Date of
Testing

28/03/15

7.675

Failure
Load
(kN)
510

7.770

490

21.78

7.730

500

22.22

Weight
(Kg)

Compressive
Strength (MPa)
22.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15203

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. SSE/W/MYS/ dated 25/03/15.

Project*

: Abutment & Return walls, Mysore-Arsikere Section,


Elimination of Manned level crossing No: 15 @ km
17/800-900 by construction of ROB.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 5th lift.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

: 150 mm x 150 mm x 150 mm


Date of
Casting

18/03/15

Date of
Testing

28/03/15

7.770

Failure
Load
(kN)
510

7.920

520

23.11

7.865

540

24.00

Weight
(Kg)

Compressive
Strength (MPa)
22.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15202

Date: 31/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 28/03/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 4th Floor Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

25/02/15

28/03/15

8.115
8.075
8.070

Failure
Load
(kN)
580
550
705

Compressive
Strength (MPa)
25.78
24.44
31.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15205

Date: 31/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysore Division, Mysore.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 28/03/15

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
540
230
200

Compressive
Strength (MPa)

1
-7.885
21/03/15
28/03/15
2
-7.945
3
-7.805
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

24.00
10.22
8.89

Testing officer

CRC No: 15198

Date: 31/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D-Block Slab concrete (2nd floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
380
345
200

Compressive
Strength (MPa)

1
-8.480
20/03/15
27/03/15
2
-8.415
3
-8.415
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

16.89
15.33
8.89

Testing officer
CRC No: 15108

Date: 31/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 18/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D- Block column concrete (First Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
-7.580
555
02/03/15
30/03/15
2
-7.560
560
3
-7.485
700
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

24.67
24.89
31.11

Testing officer
CRC No: 15079

Date: 28/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 04/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D Block Slab Concrete. Ground Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/02/15

Date of
Testing

Weight
(Kg)

25/03/15

7.425
7.465
7.405

Failure
Load
(kN)
600
540
660

Compressive
Strength (MPa)
26.67
24.00
29.33

Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15160

Date: 23/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C-block Column concrete (First Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
680
180
200

1
-7.840
12/03/15
19/03/15
2
-7.830
3
-7.800
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
30.22
8.0
8.89

3. Any correction invalidates this report.


Testing officer

CRC No: 15160

Date: 23/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. 6SI-Block column concrete (Ground Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
200
180
190

1
-7.730
12/03/15
19/03/15
2
-7.760
3
-7.810
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
8.89
8.0
8.44

Testing officer

CRC No: 15160

Date: 23/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. F-Block Ground beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
210
180
185

1
-7.835
12/03/15
19/03/15
2
-7.710
3
-7.795
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
9.33
8.0
8.22

Testing officer

CRC No: 15208

Date: 31/03/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 30/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C-Block slab concrete (2nd floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
300
380
300

1
-8.455
23/03/15
30/03/15
2
-8.325
3
-8.100
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
13.33
16.89
13.33

Testing officer

CRC No: 15207/a

Date: 30/03/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Secretary, Mysore Diocesan Educational Society (Regd),


Jayalakshmipuram, Mysore.

Ref No

: Letter No. MDES/245/2014-15 dated 28/03/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
610
640
650

1
-8.050
-28/03/15
2
-8.040
3
-7.920
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
27.11
28.44
28.89

Testing officer

CRC No: 15218

Date: 04/04/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: RMC Ready Mix (India), Mysore.

Ref No

: Letter dated 01/04/15.

Project*

: Vijayanagar, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
740
795
750

Compressive
Strength (MPa)

1
-8.100
04/03/15
01/04/15
2
-8.165
3
-8.065
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

32.89
35.33
33.33

Testing officer

CRC No: 15217

Date: 04/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sanria Team 4 Ventures, T.K. Layout, Mysore-09.

Ref No

: Letter No. ST4/2014-15/17 dated 01/04/15.

Project*

: Apartment at Vijayanagar 1st Stage, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/03/15

Date of
Testing

Weight
(Kg)

01/04/15

8.065
8.120
8.250

Failure
Load
(kN)
630
650
660

Compressive
Strength (MPa)
28.00
28.89
29.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15215

Date: 04/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 01/04/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Second floor slab (Balance 50%)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/03/15

01/04/15

8.035
8.050
8.115

Failure
Load
(kN)
500
575
540

Compressive
Strength (MPa)
22.22
25.55
24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15221

Date: 07/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 06/04/15

Project*

: Construction of Sub way @ Mysore Railway station, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/03/15

Date of
Testing

Weight
(Kg)

06/04/15

8.080
8.165
8.195

Failure
Load
(kN)
880
1000
1020

Compressive
Strength (MPa)
39.11
44.44
45.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15220

Date: 07/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal Indl Area, Mysore.

Ref No

: Letter dated 04/04/15.

Project*

: Damden Solarium, Plot No. 36 & 37, Ring Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 5 Fifth floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

26/03/15

04/04/15

8.095
8.180
8.185

Failure
Load
(kN)
490
500
600

Compressive
Strength (MPa)
21.78
22.22
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15153

Date: 06/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 16/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples
by the Client.

: Sample Supplied

Grade of Concrete*

: M20. C block Slab Concrete (G.F)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
450
540
600

Compressive
Strength (MPa)

1
-7.640
09/03/15
04/04/15
2
-7.405
3
-7.570
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

20.00
24.00
26.67

Testing officer

CRC No: 15124

Date: 06/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 12/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. B block Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
780
750
710

1
-7.625
05/03/15
04/04/15
2
-7.585
3
-7.680
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
34.67
33.33
31.55

Testing officer

CRC No: 15230

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 08/04/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

10/03/15

08/04/15

8.065
8.100
7.765

Failure
Load
(kN)
500
1100
620

Compressive
Strength (MPa)
22.22
48.89
27.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15230

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 08/04/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

28/02/15

08/04/15

7.755

Failure
Load
(kN)
665

Compressive
Strength (MPa)
29.55

2
3

---

7.690
7.680

640
560

28.44
24.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15233

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. RAL Constructions, Thandya Industrial Area, Nanjangud.

Ref No

: Letter dated 08/04/15.

Project*

: Construction of Rishi Project Site, Nanjangud, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-26/03/15
08/04/15
2
-3
-Note:
1.* Informatin furnished by the client.

Weight
(Kg)
7.720
8.015
8.165

Failure
Load
(kN)
450
510
590

Compressive
Strength (MPa)
20.00
22.67
26.22

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15233

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. RAL Constructions, Thandya Industrial Area, Nanjangud.

Ref No

: Letter dated 08/04/15.

Project*

: Construction of Rishi Project Site, Nanjangud, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
650
640
460

1
-8.000
27/03/15
08/04/15
2
-7.895
3
-8.015
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
28.89
28.44
20.44

Testing officer

CRC No: 15237

Date: 10/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 09/04/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
06/03/15

Date of
Testing

Weight
(Kg)

09/04/15

7.940
7.930
7.830

Failure
Load
(kN)
690
620
620

Compressive
Strength (MPa)
30.67
27.55
27.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15237

Date: 10/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 09/04/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/04/15

Date of
Testing

Weight
(Kg)

09/04/15

8.175
8.290
8.070

Failure
Load
(kN)
630
600
450

Compressive
Strength (MPa)
28.00
26.67
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15232

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/23 dated 08/04/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
495
485
480

1
A1
8.365
2
A2
01/04/15
08/04/15
8.365
3
A3
8.445
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.00
21.55
21.33

Testing officer

CRC No: 15232

Date: 09/04/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/23 dated 08/04/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
580
590
550

1
B1
8.095
2
B2
01/04/15
08/04/15
8.240
3
B3
8.605
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
25.78
26.22
24.44

Testing officer

CRC No: 15239

Date: 11/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: --

Project*

: SDM College, JLB Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Pile.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/03/15

09/04/15

7.750
7.925
7.735

Failure
Load
(kN)
630
700
610

Compressive
Strength (MPa)
28.00
31.11
27.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15238

Date: 11/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Dy. CE/CN/HQ/BNC, SWR, Mysore.

Ref No

: Letter No. W.148/RMGM-MYS/DL/73897 dated 09/04/15.

Project*

: Ramanagaram-Mysore doubling project-Proposed


Construciton of Rail level goods Platform, Provision of Colony
Roads, drainage arrangements for Staff quarters at
Chennapattana, Mandya and Pandavapura stations.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/03/15

09/04/15

7.975
8.035
--

Failure
Load
(kN)
1100
1200
--

Compressive
Strength (MPa)
48.89
53.33
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15166

Date: 11/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme

(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum


Turnkey Basis.
Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D-Block Slab Concrete (First Floor).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
710
400
435

Compressive
Strength (MPa)

1
-8.140
13/03/15
10/04/15
2
-7.995
3
-8.340
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

31.55
17.78
19.33

Testing officer
CRC No: 15166

Date: 11/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. B-Block Ground beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
480
680
680

Compressive
Strength (MPa)

1
-8.240
14/03/15
11/04/15
2
-8.425
3
-8.085
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

21.33
30.22
30.22

Testing officer
CRC No: 15166

Date: 11/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D-Block column concrete (2nd Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
510
500
590

Compressive
Strength (MPa)

1
-8.510
15/03/15
11/04/15
2
-8.350
3
-8.415
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

22.67
22.22
26.22

Testing officer
CRC No: 15244

Date: 13/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysore Division, Mysore.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No
10/04/15.

: Letter dated

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


ID No.
Sl
Date of
No
Casting

: 150 mm x 150 mm x 150 mm


Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
600
620
600

1
-7.650
13/03/15
10/04/15
2
-7.840
3
-7.760
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
26.67
27.55
26.67

Testing officer

CRC No: 15264

Date: 17/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Foundations, Saraswathipuram, Mysore.

Ref No

: Letter dated 16/04/15.

Project*

: Foundations Pruthvi.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 4th Floor Roof Slab (Ultratech).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

19/03/15

17/04/15

8.550
8.550
8.400

770
650
695

34.22
28.89
30.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15228

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client
(O), SWR, Mysore.

: SSE/W/

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 9 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

28/03/15

07/04/15

7.710

810

36.00

7.840

760

33.78

8.020

790

35.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15228

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 10 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

31/03/15

07/04/15

7.760

750

33.33

7.915

745

33.11

7.920

760

33.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15228

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 11 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

01/04/15

08/04/15

7.875

800

35.55

7.980

780

34.67

7.985

850

37.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15228

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 1 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

06/03/15

07/04/15

8.040

905

40.22

8.150

920

40.89

7.990

900

40.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15228

Date: 09/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 2 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

08/03/15

07/04/15

8.120

945

42.00

8.130

900

40.00

7.980

920

40.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15245

Date: 13/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 13 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

04/04/15

11/04/15

8.200

780

34.67

8.360

750

33.33

7.990

790

35.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15245

Date: 13/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 12 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1

--

--

--

02/04/15

11/04/15

8.130

750

33.33

8.030

780

34.67

8.100

700

31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15241

Date: 13/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: L. Narayan, Site Owner, Visheshwanagar, Mysore.

Ref No

: --

Project*

: Apartment at Vishweshwaranagar II Stage,


Mysore South.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Roof Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

18/03/15

09/04/15

8.195
8.320
8.530

505
650
600

22.44
28.89
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15250

Date: 15/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 13/04/15.

Project*

: Construction of Sub way @ Mysore Railway station, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

08/03/15

13/04/15

8.035

Failure
Load
(kN)
820

Compressive
Strength (MPa)
36.44

2
3

---

8.990
7.965

900
995

40.00
44.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15259

Date: 17/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 16/04/15.

Project*

: SDM College, JLB Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

08/04/15

16/04/15

8.285

Failure
Load
(kN)
610

Compressive
Strength (MPa)
27.11

2
3

---

8.205
8.305

640
570

28.44
25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15257

Date: 17/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/34 dated 15/04/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
C1
7.870
565
2
C2
08/04/15
15/04/15
7.635
520
3
C3
7.655
585
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

25.11
23.11
26.00

Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 17 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

08/04/15

Date of
Testing

15/04/15

8.150

Failure
Load
(kN)
700

8.135

790

35.11

8.165

750

33.33

Weight
(Kg)

Compressive
Strength (MPa)
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 15 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

06/04/15

1.* Information furnished by the client.

Date of
Testing

15/04/15

7.950

Failure
Load
(kN)
760

8.135

800

35.55

8.220

735

32.67

Weight
(Kg)

Compressive
Strength (MPa)
33.78

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 16 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

07/04/15

Date of
Testing

15/04/15

8.155

Failure
Load
(kN)
790

8.220

740

32.89

8.155

740

32.89

Weight
(Kg)

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
35.11

3. Any correction invalidates this report.


Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 14 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

05/04/15

Date of
Testing

15/04/15

8.240

Failure
Load
(kN)
650

8.220

760

33.78

8.060

800

35.55

Weight
(Kg)

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
28.89

Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 5 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

17/03/15

Date of
Testing

15/04/15

8.200

Failure
Load
(kN)
850

8.095

880

39.11

8.010

900

40.00

Weight
(Kg)

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
37.78

Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 8 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

21/03/15

Date of
Testing

18/04/15

7.945

Failure
Load
(kN)
890

8.100

860

38.22

8.010

840

37.33

Weight
(Kg)

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
39.55

Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 4 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

16/03/15

Date of
Testing

15/04/15

8.120

Failure
Load
(kN)
850

8.145

950

42.22

8.200

850

37.78

Weight
(Kg)

Compressive
Strength (MPa)
37.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 3 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

15/03/15

Date of
Testing

15/04/15

8.235

Failure
Load
(kN)
825

8.245

890

39.55

8.280

900

40.00

Weight
(Kg)

Compressive
Strength (MPa)
36.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 6 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

19/03/15

Date of
Testing

16/04/15

7.990

Failure
Load
(kN)
925

8.010

900

40.00

8.045

960

42.67

Weight
(Kg)

Compressive
Strength (MPa)
41.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15255

Date: 18/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter LOA NO. Y/W.148/I/3401 dated 06/02/14.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-500 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 7 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

20/03/15

Date of
Testing

17/04/15

8.010

Failure
Load
(kN)
960

7.965

900

40.00

8.005

960

42.67

Weight
(Kg)

Compressive
Strength (MPa)
42.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15160

Date: 10/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C-block Column concrete (First Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
420
470
500

1
-8.205
12/03/15
09/04/15
2
-8.200
3
-8.100
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
18.67
20.89
22.22

Testing officer

CRC No: 15160

Date: 10/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. 6SI-Block column concrete (Ground Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
550
650
500

1
-8.215
12/03/15
09/04/15
2
-8.130
3
-8.200
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
24.44
28.89
22.22

Testing officer

CRC No: 15160

Date: 10/04/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 19/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. F-Block Ground beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
570
555
535

1
-8.205
12/03/15
09/04/15
2
-8.150
3
-8.190
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
25.33
24.67
23.78

Testing officer

CRC No: 15173

Date: 15/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 23/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C-Block Slab Concrete (First Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
610
305
450

Compressive
Strength (MPa)

1
-7.980
16/03/15
13/04/15
2
-7.975
3
-7.960
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

27.11
13.55
20.00

Testing officer
CRC No: 15173

Date: 15/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 23/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. F-Block Plinth Beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
250
280
320

Compressive
Strength (MPa)

1
-8.020
16/03/15
13/04/15
2
-7.940
3
-7.990
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

11.11
12.44
14.22

Testing officer

CRC No: 15189

Date: 16/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C-Block Column Concrete (2nd Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
580
380
400

Compressive
Strength (MPa)

1
-8.160
18/03/15
15/04/15
2
-8.325
3
-8.375
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

25.78
16.89
17.78

Testing officer

CRC No: 15181

Date: 15/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 24/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum

Turnkey Basis.
Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. B-Block Pinth beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
250
550
370

1
-8.360
17/03/15
13/04/15
2
-8.110
3
-8.315
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
11.11
24.44
16.44

Testing officer

CRC No: 15265

Date: 20/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 17/04/15.

Project*

: CARP.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Roof Concrete (CARP)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

10/04/15

Date of
Testing

Weight
(Kg)

17/04/15

8.130
8.185
8.281
8.490
8.240
8.440

Failure
Load
(kN)
530
440
400
605
620
680

Compressive
Strength (MPa)
23.55
19.55
17.78
26.89
27.55
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15265

Date: 20/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 17/04/15.

Project*

: CARP.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Roof Concrete (CARP)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

7
8
9
10
11
12
13
14
15

----------

: 150 mm x 150 mm x 150 mm


Date of
Casting

10/04/15

Date of
Testing

Weight
(Kg)

17/04/15

8.280
8.390
8.120
8.320
8.250
8.205
8.200
7.935
8.100

Failure
Load
(kN)
430
620
490
520
590
450
660
480
550

Compressive
Strength (MPa)
19.11
27.55
21.78
23.11
26.22
20.00
29.33
21.33
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15270

Date: 22/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysore Division, Mysore.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 24/03/15

Project*

: Construction of New RTO Office @ Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing Concrete,

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

: 150 mm x 150 mm x 150 mm


Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
665
650
600

1
-7.355
21/03/15
20/04/15
2
-7.570
3
-7.530
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
29.55
28.88
26.67

Testing officer

CRC No: 15274

Date: 23/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal Indl Area, Mysore.

Ref No

: Letter dated 22/04/15.

Project*

: Damden Solarium, Plot No. 36 & 37, Ring Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 5 Fifth floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

26/03/15

22/04/15

8.080
8.045
8.450

650
710
750

28.89
31.55
33.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15274

Date: 23/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal Indl Area, Mysore.

Ref No

: Letter dated 22/04/15.

Project*

: Damden Solarium, Plot No. 36 & 37, Ring Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 5 Fifth floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

14/04/15

22/04/15

7.940
7.900
8.320

435
300
550

19.33
13.33
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15198

Date: 20/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/03/15

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters in


Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGE NO: 33/2013-14) on Lump sum
Turnkey Basis.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. D-Block Slab concrete (2nd floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
-8.430
580
20/03/15
17/04/15
2
-8.240
460
3
-8.500
420
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

25.78
20.44
18.67

Testing officer

CRC No: 15208

Date: 22/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH&IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 30/03/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


In Kodagu district, under Police Gruha 2020 Scheme
(PG-2020/PACKAGENO: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. C-Block slab concrete (2nd floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/03/15

Date of
Testing

Weight
(Kg)

20/04/15

8.665
7.400
8.470

Failure
Load
(kN)
535
485
520

Compressive
Strength (MPa)
23.78
21.55
23.11

Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15285

Date: 28/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Gina Engineering Company (P) Ltd, Mysore.

Ref No

: Letter dated 27/04/15.

Project*

: Theorem Production Block-4.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Canteen front side road.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/04/15

Date of
Testing

Weight
(Kg)

27/04/15

8.240
8.140
8.120

Failure
Load
(kN)
770
700
530

Compressive
Strength (MPa)
34.22
31.11
23.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15284

Date: 29/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 27/04/15.

Project*

: Construction of CARP office complex @ CAR, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd Floor Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

20/04/15

27/04/15

8.180
8.475
8.325

Failure
Load
(kN)
700
600
725

Compressive
Strength (MPa)
31.11
26.67
32.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15284

Date: 29/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 27/04/15.

Project*

: Construction of CARP office complex @ CAR, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd Floor Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/04/15

28/04/15

8.345
8.365
8.230

Failure
Load
(kN)
480
570
770

Compressive
Strength (MPa)
21.33
25.33
34.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15280

Date: 27/04/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: --

Project*

: Construction of Sub way @ Mysore Railway station, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
14/03/15

Date of
Testing

Weight
(Kg)

24/04/15

8.085
8.150
8.100

Failure
Load
(kN)
800
1100
930

Compressive
Strength (MPa)
35.55
48.89
41.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15280

Date: 27/04/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: --

Project*

: Construction of Sub way @ Mysore Railway station, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/03/15

24/04/15

7.995
7.995
7.945

Failure
Load
(kN)
850
890
1000

Compressive
Strength (MPa)
37.78
39.55
44.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15292

Date: 30/04/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 29/04/15.

Project*

: SDM College, JLB Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/04/15

Date of
Testing

Weight
(Kg)

29/04/15

8.450
8.270
8.035

Failure
Load
(kN)
260
430
380

Compressive
Strength (MPa)
11.55
19.11
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15295

Date: 30/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 29/04/15.

Project*

: Construction of CARP office complex @ CAR, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd Floor Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

22/04/15

29/04/15

8.040
7.980
8.170

Failure
Load
(kN)
345
400
390

Compressive
Strength (MPa)
15.33
17.78
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15295

Date: 30/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 29/04/15.

Project*

: Construction of CARP office complex @ CAR, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd Floor Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/04/15

Date of
Testing

Weight
(Kg)

30/04/15

7.830
7.790
7.760

Failure
Load
(kN)
250
230
260

Compressive
Strength (MPa)
11.11
10.22
11.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15288

Date: 30/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter No. SSE/W/(O)/MYS dated 25/04/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 10 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

31/03/15

Date of
Testing

28/04/15

8.070

Failure
Load
(kN)
980

7.970

900

40.00

7.950

1000

44.44

Weight
(Kg)

Compressive
Strength (MPa)
43.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15288

Date: 30/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter No. SSE/W/(O)/MYS dated 25/04/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 11 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

01/04/15

Date of
Testing

28/04/15

7.955

Failure
Load
(kN)
910

8.075

950

42.22

7.995

900

40.00

Weight
(Kg)

Compressive
Strength (MPa)
40.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15288

Date: 30/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter No. SSE/W/(O)/MYS dated 25/04/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 9 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

28/03/15

Date of
Testing

25/04/15

7.890

Failure
Load
(kN)
900

7.995

1000

44.44

8.000

890

39.55

Weight
(Kg)

Compressive
Strength (MPa)
40.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15293

Date: 30/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/74 dated 28/04/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
690
720
750

Compressive
Strength (MPa)

1
A4
8.195
2
A5
01/04/15
29/04/15
8.355
3
A6
8.180
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

30.67
32.00
33.33

Testing officer

CRC No: 15294

Date: 30/04/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/75 dated 28/04/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
800
790
750

1
B4
8.280
2
B5
01/04/15
29/04/15
8.255
3
B6
8.150
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
35.55
35.11
33.33

Testing officer

CRC No: 15290

Date: 02/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Dy. CE/CN/HQ/BNC, SWR, Mysore.

Ref No

: Letter No. W.148/RMGM-MYS/DL/73897 dated 12/04/15.

Project*

: Ramanagaram-Mysore doubling project-Proposed


Construction of Rail level goods Platform, Provision of Colony
Roads, drainage arrangements for Staff quarters at Mandya and
Construction of SSE/P.Way, SSE/Works, ADEN offices at
Chennapattana, Mandya and Pandavapura stations.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

10/03/15

29/04/15

7.740
7.605
7.760

Failure
Load
(kN)
1000
1050
1040

Compressive
Strength (MPa)
44.44
46.67
46.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15290

Date: 02/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Dy. CE/CN/HQ/BNC, SWR, Mysore.

Ref No

: Letter No. W.148/RMGM-MYS/DL/73897 dated 29/04/15.

Project*

: Ramanagaram-Mysore doubling project-Proposed


Construction of Rail level goods Platform, Provision of Colony
Roads, drainage arrangements for Staff quarters at Mandya and
Construction of SSE/P.Way, SSE/Works, ADEN offices at
Chennapattana, Mandya and Pandavapura stations.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

01/04/15

29/04/15

7.675

Failure
Load
(kN)
1100

Compressive
Strength (MPa)
48.89

2
3

---

7.800
7.675

1085
1040

48.22
46.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15290

Date: 02/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Dy. CE/CN/HQ/BNC, SWR, Mysore.

Ref No

: Letter No. W.148/RMGM-MYS/DL/73897 dated 20/04/15.

Project*

: Ramanagaram-Mysore doubling project-Proposed


Construction of Rail level goods Platform, Provision of Colony
Roads, drainage arrangements for Staff quarters at Mandya and
Construction of SSE/P.Way, SSE/Works, ADEN offices at
Chennapattana, Mandya and Pandavapura stations.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/03/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

29/04/15

7.750
7.720
7.805

Failure
Load
(kN)
1075
1110
1010

Compressive
Strength (MPa)
47.78
49.33
44.89

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15290

Date: 02/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Dy. CE/CN/HQ/BNC, SWR, Mysore.

Ref No

: Letter No. W.148/RMGM-MYS/DL/73897 dated 15/04/15.

Project*

: Ramanagaram-Mysore doubling project-Proposed


Construction of Rail level goods Platform, Provision of Colony
Roads, drainage arrangements for Staff quarters at Mandya and
Construction of SSE/P.Way, SSE/Works, ADEN offices at
Chennapattana, Mandya and Pandavapura stations.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/03/15

Date of
Testing

Weight
(Kg)

29/04/15

7.765
7.685
7.950

Failure
Load
(kN)
700
620
580

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
31.11
27.55
25.78

Testing officer

CRC No: 15290

Date: 02/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Dy. CE/CN/HQ/BNC, SWR, Mysore.

Ref No

: Letter No. W.148/RMGM-MYS/DL/73897 dated 18/04/15.

Project*

: Ramanagaram-Mysore doubling project-Proposed


Construction of Rail level goods Platform, Provision of Colony
Roads, drainage arrangements for Staff quarters at Mandya and
Construction of SSE/P.Way, SSE/Works, ADEN offices at
Chennapattana, Mandya and Pandavapura stations.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/03/15

Date of
Testing

Weight
(Kg)

29/04/15

8.850
7.730
7.845

Failure
Load
(kN)
465
620
640

Compressive
Strength (MPa)
21.55
27.55
28.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15298

Date: 02/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE, Works, South Western Railway, Mysore.

Ref No

: Letter dated 30/04/2015.

Project*

: RPF Mobilization Hall (35 beds), Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/04/15

30/04/15

7.385
7.425
7.555

Failure
Load
(kN)
100
100
100

Compressive
Strength (MPa)
4.44
4.44
4.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15308

Date: 07/05/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 05/05/15.

Project*

: Construction of CARP & Dormitory recreation hall at CAR,


Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd Floor Column Concrete CARP Site.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
28/04/15

Date of
Testing

Weight
(Kg)

05/05/15

7.825
7.800
7.960

Failure
Load
(kN)
500
380
400

Compressive
Strength (MPa)
22.22
16.89
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15308

Date: 07/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHC, Mysore.

Ref No

: Letter dated 05/05/15.

Project*

: Construction of CARP & Dormitory recreation hall at CAR,


Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd Floor Column Concrete CARP Site.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

29/04/15

06/05/15

8.550
7.615
7.680

Failure
Load
(kN)
180
210
200

Compressive
Strength (MPa)
8.0
9.33
8.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15305

Date: 06/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: K.A. Gopinath, Railway Contractor, Vijayanagar, Mysore.

Ref No

: Letter dated 04/05/15.

Project*

: RPF Mobilization Hall (35 beds), Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/04/15

Date of
Testing

Weight
(Kg)

04/05/15

7.595
7.795
7.875

Failure
Load
(kN)
200
150
200

Compressive
Strength (MPa)
8.89
6.67
8.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15300

Date: 04/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: K.A. Gopinath, Railway Contractor, Vijayanagar, Mysore.

Ref No

: Letter dated 02/05/15.

Project*

: RPF Mobilization Hall (35 beds), Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/04/15

Date of
Testing

Weight
(Kg)

02/05/15

7.605
7.680
8.335

Failure
Load
(kN)
120
160
100

Compressive
Strength (MPa)
5.33
7.11
4.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15310

Date: 07/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 05/05/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Second floor slab (Balance 50%) (RMC India Concrete).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/03/15

Date of
Testing

Weight
(Kg)

05/05/15

8.230
8.115
8.225

Failure
Load
(kN)
800
765
700

Compressive
Strength (MPa)
35.55
34.00
31.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15310

Date: 07/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 05/05/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, VDF flooring for Basement floor (MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

16/04/15

05/05/15

8.180
8.055
7.970

400
445
395

17.78
19.78
17.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15310

Date: 07/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 05/05/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Exit ramp Raft (Balance 50%) (RMC India Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

28/03/15

05/05/15

8.250
8.315
8.175

Failure
Load
(kN)
880
920
845

Compressive
Strength (MPa)
39.11
40.89
37.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15310

Date: 07/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 05/05/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, VDF flooring for Basement floor (MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/04/15

Date of
Testing

Weight
(Kg)

05/05/15

7.815
7.890
7.775

Failure
Load
(kN)
395
405
400

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
17.55
18.00
17.78

Testing officer

CRC No: 15310

Date: 07/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 05/05/15.

Project*

: Construction of Dr. Babu Jagajeevan Ram Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Part terrace floor & Head room slab (MSR Concrete).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/01/15

Date of
Testing

Weight
(Kg)

05/05/15

7.715
7.865
7.715

Failure
Load
(kN)
680
650
710

Compressive
Strength (MPa)
30.22
28.89
31.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15318

Date: 09/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/93(A) dated 05/05/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
780
800
800

1
C4
7.775
2
C5
08/04/15
07/05/15
7.770
3
C6
7.895
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
34.67
35.55
35.55

Testing officer

CRC No: 15322

Date: 09/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 07/05/15.

Project*

: Construction of Sub way @ Mysore Railway station, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/04/15

08/05/15

8.200
8.105
8.205

Failure
Load
(kN)
620
870
720

Compressive
Strength (MPa)
27.55
38.67
32.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15326

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 08/05/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Roof Concrete, CARP Site.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3
4
5
6

ID No.

Date of
Casting

Date of
Testing

-------

10/04/15

08/05/15

Weight
(Kg)
7.695
7.970
7.820
8.060
8.395
8.120

Failure Load
(kN)
240
200
310
750
790
650

Compressive
Strength (MPa)
10.67
8.89
13.78
33.33
35.11
28.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15326

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 08/05/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Roof Concrete, CARP Site.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
7
8
9
10
11
12

ID No.

Date of
Casting

Date of
Testing

-------

10/04/15

08/05/15

Weight
(Kg)
7.790
7.650
7.855
7.830
8.055
7.815

Failure Load
(kN)
270
330
280
250
285
250

Compressive
Strength (MPa)
12.00
14.67
12.44
11.11
12.67
11.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15326

Date: 11/05/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 08/05/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, FF Roof Concrete, CARP Site.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
13
14
15

ID No.

Date of
Casting

Date of
Testing

----

10/04/15

08/05/15

Weight
(Kg)
8.075
7.990
8.070

Failure Load
(kN)
350
535
500

Compressive
Strength (MPa)
15.55
23.78
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15327

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/93(A) dated 05/05/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Grade Beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
495
490
500

1
GB1
8.420
2
GB2
02/05/15
09/05/15
8.455
3
GB3
8.055
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
22.00
21.78
22.22

3. Any correction invalidates this report.


Testing officer

CRC No: 15296

Date: 08/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter dated 08/05/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 12 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

02/04/15

Date of
Testing

30/04/15

8.345

Failure
Load
(kN)
830

8.205

930

41.33

8.260

900

40.00

Weight
(Kg)

Compressive
Strength (MPa)
36.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15296

Date: 08/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter dated 08/05/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 13 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

04/04/15

Date of
Testing

02/05/15

8.060

Failure
Load
(kN)
830

8.000

950

42.22

8.050

900

40.00

Weight
(Kg)

Compressive
Strength (MPa)
36.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15296

Date: 08/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter dated 08/05/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 15 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

06/04/15

Date of
Testing

04/05/15

8.160

Failure
Load
(kN)
1000

8.250

960

42.66

8.120

900

40.00

Weight
(Kg)

Compressive
Strength (MPa)
44.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15296

Date: 08/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter dated 08/05/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 14 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

05/04/15

Date of
Testing

04/05/15

8.145

Failure
Load
(kN)
930

8.190

900

40.00

8.245

890

39.55

Weight
(Kg)

Compressive
Strength (MPa)
41.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15309

Date: 08/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter dated 08/05/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 17 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

08/04/15

Date of
Testing

06/05/15

8.015

Failure
Load
(kN)
980

8.120

960

42.67

8.165

930

41.33

Weight
(Kg)

Compressive
Strength (MPa)
43.65

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15309

Date: 08/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/W/ (O), SWR, Mysore.

Ref No

: Letter dated 08/05/15.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, RUB Segment No. 16 (4.0mx4.15m) I/I

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

07/04/15

Date of
Testing

05/05/15

8.055

Failure
Load
(kN)
900

8.290

900

40.00

8.200

890

39.55

Weight
(Kg)

Compressive
Strength (MPa)
40.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15329

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Gina Engineering Company (P) Ltd, Mysore.

Ref No

: Letter dated 09/05/15.

Project*

: Theorem Production Block-4.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, near transform.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

29/04/15

09/05/15

8.405
8.310
8.135

Failure
Load
(kN)
690
630
500

Compressive
Strength (MPa)
30.67
28.00
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Intake well side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/04/15

Date of
Testing

Weight
(Kg)

09/05/15

8.035
8.180
7.930

Failure
Load
(kN)
550
630
430

Compressive
Strength (MPa)
24.44
28.00
19.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, CWR Side Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

01/05/15

09/05/15

7.610
7.500
7.510

Failure
Load
(kN)
425
370
395

Compressive
Strength (MPa)
18.89
16.44
17.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, CWR Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/04/15

09/05/15

7.600
7.965
7.700

Failure
Load
(kN)
350
470
350

Compressive
Strength (MPa)
15.55
20.89
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/03/15

Date of
Testing

Weight
(Kg)

09/05/15

8.160
8.320
8.130

Failure
Load
(kN)
330
570
590

Compressive
Strength (MPa)
14.67
25.33
26.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Clarifaculator side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3

----

: 150 mm x 150 mm x 150 mm


Date of
Casting
14/04/15

Date of
Testing

Weight
(Kg)

09/05/15

7.905
8.055
7.890

Failure
Load
(kN)
460
330
520

Compressive
Strength (MPa)
20.44
14.67
23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Clarifaculator Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/04/15

09/05/15

8.380
8.240
8.120

Failure
Load
(kN)
630
650
550

Compressive
Strength (MPa)
28.00
28.89
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column above Bracing beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

27/04/15

09/05/15

8.080

Failure
Load
(kN)
350

Compressive
Strength (MPa)
15.55

2
3

---

8.140
8.170

375
350

16.67
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR I Column below G/L.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
08/04/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

09/05/15

7.955
8.220
8.230

Failure
Load
(kN)
470
690
300

Compressive
Strength (MPa)
20.89
30.67
13.33

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/04/15

Date of
Testing

Weight
(Kg)

09/05/15

8.240
7.940
7.870

Failure
Load
(kN)
575
400
440

Compressive
Strength (MPa)
25.55
17.78
19.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Intake well Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/04/15

Date of
Testing

Weight
(Kg)

09/05/15

8.200
7.995
8.420

Failure
Load
(kN)
570
600
710

Compressive
Strength (MPa)
25.33
26.67
31.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15330

Date: 11/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 09/05/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, OMBR I Bracing beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/04/15

09/05/15

8.210
8.455
8.190

Failure
Load
(kN)
750
700
690

Compressive
Strength (MPa)
33.33
31.11
30.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15340

Date: 13/05/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 12/05/15.

Project*

: SDM College, JLB Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/05/15

Date of
Testing

Weight
(Kg)

12/05/15

8.350
8.190
8.270

Failure
Load
(kN)
360
515
390

Compressive
Strength (MPa)
16.00
22.89
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15340

Date: 13/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 12/05/15.

Project*

: SDM College, JLB Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/05/15

12/05/15

8.040
8.535
8.320

Failure
Load
(kN)
760
500
760

Compressive
Strength (MPa)
33.78
22.22
33.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15339

Date: 13/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, K.R.E.I.S,


Chamarajanagar. Agency: NB Construction Company.

Ref No

: Letter dated 11/05/15

Project*

: Construction of K.R.C.R.S @ Begur.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 20, Green Room Roof & beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

13/04/15

11/05/15

Weight
(Kg)
8.140
8.175
8.130

Failure Load
(kN)
605
600
620

Compressive
Strength (MPa)
26.89
26.67
27.56

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15339

Date: 13/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, K.R.E.I.S,


Chamarajanagar. Agency: NB Construction Company.

Ref No

: Letter dated 11/05/15

Project*

: Construction of K.R.C.R.S @ Begur.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 20, C.C. Drains.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

14/04/15

12/05/15

Weight
(Kg)
8.430
8.360
8.300

Failure Load
(kN)
590
585
600

Compressive
Strength (MPa)
26.22
26.00
26.67

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15339

Date: 13/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, K.R.E.I.S,


Chamarajanagar. Agency: NB Construction Company.

Ref No

: Letter dated 11/05/15

Project*

: Construction of K.R.C.R.S @ Begur.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 20, Deck Slabs.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

15/04/15

13/05/15

Weight
(Kg)
8.005
8.170
8.215

Failure Load
(kN)
308
588
605

Compressive
Strength (MPa)
27.0
26.1
26.89

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15339

Date: 13/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, K.R.E.I.S,


Chamarajanagar. Agency: NB Construction Company.

Ref No

: Letter dated 11/05/15

Project*

: Construction of M.D.R.S Complex @ Hangala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 20, Principal Quarters, Roof & Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

13/04/15

11/05/15

Weight
(Kg)
8.055
8.090
8.065

Failure Load
(kN)
630
630
625

Compressive
Strength (MPa)
28.00
28.00
27.78

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15339

Date: 13/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, K.R.E.I.S,


Chamarajanagar. Agency: NB Construction Company.

Ref No

: Letter dated 11/05/15

Project*

: Construction of M.D.R.S Complex @ Hangala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 20, O.H.T (Boys & Girls Dormitory)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

----

14/04/15

12/05/15

Weight
(Kg)
8.250
8.195
8.020

Failure Load
(kN)
620
600
610

Compressive
Strength (MPa)
27.56
26.67
27.11

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15339

Date: 13/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, K.R.E.I.S,


Chamarajanagar. Agency: NB Construction Company.

Ref No

: Letter dated 11/05/15

Project*

: Construction of M.D.R.S Complex @ Hangala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 20, CC Drains.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

15/04/15

13/05/15

Weight
(Kg)
7.665
7.620
7.810

Failure Load
(kN)
580
600
595

Compressive
Strength (MPa)
25.78
26.67
26.44

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15344


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sri. H.S. Ramesh, Contractor, Mysore.

Ref No

: Letter dated 30/03/2015.

Project*

: Concrete pavement at NaykanaHundi village at H.D. Kote


taluk.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

04/02/15

04/03/15

8.075
8.100
8.000

720
700
720

32.00
31.11
32.00

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15344


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sri. H.S. Ramesh, Contractor, Mysore.

Ref No

: Letter dated 30/03/2015.

Project*

: Concrete drain at Naykanahundi village at H.D. Kote taluk.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2

ID No.
---

Date of
Casting
04/02/15

Date of
Testing
04/03/15

Weight
(Kg)
7.995
7.990

Failure Load
(kN)
610
605

Compressive
Strength (MPa)
27.11
26.89

--

7.990

600

26.67

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15344


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sri. H.S. Ramesh, Contractor, Mysore.

Ref No

: Letter dated 30/03/2015.

Project*

: Hard Path concrete at Sagahalli village at H.D. Kote taluk.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M 20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

05/02/15

05/03/15

Note:
1.* Information furnished by the client.

Weight
(Kg)
8.200
8.105
8.100

Failure Load
(kN)
620
620
600

Compressive
Strength (MPa)
27.56
27.56
26.67

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15347

Date: 16/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Bamboo Bazar, Mysore.

Ref No

: Letter dated 14/05/15.

Project*

: Hotel Vyshak, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/0515

Date of
Testing

Weight
(Kg)

14/05/15

8.280
8.220
8.175

Failure
Load
(kN)
565
540
560

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
25.11
24.00
24.89

Testing officer

CRC No: 15348

Date: 16/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Ess & ESS Infrastructure Pvt Ltd.

Ref No

: Letter dated 14/05/15.

Project*

: J.S.S. Layout, Varuna, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Road Culvert.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/05/15

14/05/15

8.120
8.130
8.070

Failure
Load
(kN)
405
350
395

Compressive
Strength (MPa)
18.00
15.55
17.55

Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15348

Date: 16/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Ess & ESS Infrastructure Pvt Ltd.

Ref No

: Letter dated 14/05/15.

Project*

: CA Layout, Sarakari Uttanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Road Culvert.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/04/15

14/05/15

8.080
8.130
7.590

Failure
Load
(kN)
600
575
500

Compressive
Strength (MPa)
26.67
25.55
22.22

Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15359

Date: 20/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 18/05/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/04/15

Date of
Testing

Weight
(Kg)

18/05/15

7.920
8.365
7.945

Failure
Load
(kN)
610
490
490

Compressive
Strength (MPa)
27.11
21.78
21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15358

Date: 20/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 18/05/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, VDF flooring for Basement floor (MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/04/15

Date of
Testing

Weight
(Kg)

18/05/15

7.795
7.990
8.095

Failure
Load
(kN)
660
560
580

Compressive
Strength (MPa)
29.33
24.89
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15361

Date: 21/05/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 20/05/15

Project*

: Pockets @ SY No. 278

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
13/05/15

Date of
Testing

Weight
(Kg)

20/05/15

8.320
7.885
7.815

Failure
Load
(kN)
385
400
360

Compressive
Strength (MPa)
17.11
17.78
16.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15367

Date: 22/05/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: Nirman Promoters, Mysore.

Ref No

: Letter dated 21/05/15.

Project*

: Kalpavruksha Kshetra Sri. Raghavendra Swamy Mutt,


Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

14/05/15

Date of
Testing

Weight
(Kg)

21/05/15

8.150
8.145
8.195
8.110
8.185
8.160

Failure
Load
(kN)
330
410
350
415
380
465

Compressive
Strength (MPa)
14.67
18.22
15.55
18.44
16.89
20.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15365

Date: 22/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 18/05/15

Project*

: Saptha Layout at Madapura.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

16/04/15

20/05/15

7.720
7.875
7.650

Failure
Load
(kN)
600
500
490

Compressive
Strength (MPa)
26.67
22.22
21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15369

Date: 25/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 22/05/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, VDF flooring for Basement floor (MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/04/15

22/05/15

7.950
8.150
8.130

Failure
Load
(kN)
520
550
580

Compressive
Strength (MPa)
23.11
24.44
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15374

Date: 25/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal Industrial Area, Mysore.

Ref No

: Letter dated 23/05/15.

Project*

: Damden Solarium, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 5Sixth floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/04/15

Date of
Testing

Weight
(Kg)

23/05/15

8.195
8.035
8.115

Failure
Load
(kN)
410
530
470

Compressive
Strength (MPa)
18.22
23.55
20.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15370

Date: 25/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 22/05/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd floor column concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

21/04/15

22/05/15

Weight
(Kg)
7.575
7.510
7.840

Failure Load
(kN)
580
580
600

Compressive
Strength (MPa)
25.78
25.78
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15370

Date: 25/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 22/05/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd floor column concrete at CARP at CAR Mysore.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

----

22/04/15

22/05/15

Weight
(Kg)
7.675
7.840
7.830

Failure Load
(kN)
625
630
600

Compressive
Strength (MPa)
27.78
28.00
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15370

Date: 25/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 22/05/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd floor column concrete at CARP.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

----

20/04/15

21/05/15

Weight
(Kg)
7.640
7.670
7.820

Failure Load
(kN)
665
600
500

Compressive
Strength (MPa)
29.55
26.67
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15375

Date: 26/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/147 dated 25/05/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
460
485
450

Compressive
Strength (MPa)

1
F1
8.095
2
F2
18/05/15
25/05/15
8.225
3
F3
8.440
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

20.44
21.55
20.00

Testing officer

CRC No: 15342

Date: 14/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(1)/MCSD-/II/2015/112 dated 12/05/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Failure
Load
(kN)
450
450
480

Weight
(Kg)

Compressive
Strength (MPa)

1
D1
8.115
2
D2
06/05/15
13/05/15
8.000
3
D3
7.800
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

20.00
20.00
21.33

Testing officer

CRC No: 15377

Date: 26/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysore Division, Mysore.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/05/15.

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Plinth beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3
Note:

ID No.
----

Date of
Casting
18/05/15

Date of
Testing

Weight
(Kg)

25/05/15

7.730
7.670
7.705

Failure
Load
(kN)
220
230
230

Compressive
Strength (MPa)
9.78
10.22
10.22

1.* Informatin furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15378

Date: 26/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH & IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 22/05/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020. (PG-2020/PACKAGE No: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, E Block 2nd floor Columns.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-15/05/15
22/05/15
2
-3
-Note:
1.* Informatin furnished by the client.

Weight
(Kg)
7.775
7.755
7.840

Failure
Load
(kN)
370
540
320

Compressive
Strength (MPa)
16.44
24.00
14.22

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15378

Date: 26/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH & IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/05/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020. (PG-2020/PACKAGE No: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, E Block 2nd floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
465
300
255

1
-7.855
18/05/15
25/05/15
2
-7.875
3
-7.825
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.67
13.33
11.33

Testing officer

CRC No: 15378

Date: 26/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH & IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 23/05/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020. (PG-2020/PACKAGE No: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, F Block 2nd Floor Columns.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
430
550
540

1
-7.600
16/05/15
23/05/15
2
-8.130
3
-8.030
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
19.11
24.44
24.00

Testing officer

CRC No: 15378

Date: 26/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH & IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 24/05/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020. (PG-2020/PACKAGE No: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, F Block Column Concrete (First Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
550
770
450

1
-8.015
21/04/15
25/05/15
2
-8.280
3
-8.170
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
24.44
34.22
20.00

Testing officer

CRC No: 15378

Date: 26/05/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KSPH & IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 22/05/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020. (PG-2020/PACKAGE No: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, F Block Slab Concrete (Ground Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
740
720
800

1
-7.745
19/04/15
25/05/15
2
-8.305
3
-8.335
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
32.89
32.00
35.55

Testing officer

CRC No: 15385

Date: 29/05/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: AEE, KSPH & IDCL Sub division, Kodagu, Madikeri.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/05/15.

Project*

: Construction of 78 No.s of (72PC+6SI) Police Quarters,


Madikeri, Kodagu district, Madikeri under Police Gruha
Scheme 2020. (PG-2020/PACKAGE No: 33/2013-14)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, F Block 2nd floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
530
430
570

1
-7.675
20/05/15
27/05/15
2
-7.695
3
-7.885
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
23.55
19.11
25.33

Testing officer

CRC No: 15399

Date: 03/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: T.N. Manjunath, Auditor, Ashoka Road, Mysore.

Ref No

: Letter dated 02/06/15.

Project*

: Construction of Industrial building @ Hebbal, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
640
830
--

1
-8.020
04/04/15
02/06/15
2
-8.030
3
--Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
28.44
36.89
--

Testing officer

CRC No: 15413

Date: 06/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 04/06/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pile Cap.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/05/15

04/06/15

8.380
8.025
8.575

Failure
Load
(kN)
430
620
470

Compressive
Strength (MPa)
19.11
27.55
20.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15414

Date: 08/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 05/06/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd floor roof concrete cARP Office Complex CAR


Mysore.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
Date of
ID No.
No
Casting
1
-2
-3
-4
-29/05/15
5
-6
-7
-8
--

: 150 mm x 150 mm x 150 mm


Date of
Weight
Failure Load
Testing
(Kg)
(kN)
8.050
380
8.090
390
8.385
480
8.300
550
05/06/15
8.680
380
8.485
540
8.480
390
8.395
440

Compressive
Strength (MPa)
16.89
17.33
21.33
24.44
16.89
24.00
17.33
19.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer
CRC No: 15414

Date: 08/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 05/06/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 2nd floor roof concrete cARP Office Complex CAR


Mysore.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
Date of
ID No.
No
Casting
9
-10
-11
-29/05/15
12
-13
-14
-15
--

: 150 mm x 150 mm x 150 mm


Date of
Weight
Failure Load
Testing
(Kg)
(kN)
8.400
590
8.125
440
8.250
440
05/06/15
8.145
450
8.265
540
8.260
470
8.485
480

Compressive
Strength (MPa)
26.22
19.55
19.55
20.00
24.00
20.89
21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15395

Date: 03/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/169 dated 30/05/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
740
730
720

1
GB4
8.295
2
GB5
02/05/15
01/06/15
8.600
3
GB6
8.175
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
32.89
32.44
32.00

Testing officer

CRC No: 15426

Date: 09/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: DR. Manjunath, Vijayanagar, Mysore.

Ref No

: Letter dated 08/06/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

24/05/15

08/06/15

8.225
8.090
8.095

Failure
Load
(kN)
570
470
565

Compressive
Strength (MPa)
25.33
20.89
25.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15396

Date: 03/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 01/06/15.

Project*

: Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

16/05/15

23/05/15

8.050
8.120
8.080

Failure
Load
(kN)
760
710
850

Compressive
Strength (MPa)
33.78
31.55
37.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15396

Date: 03/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 01/06/15.

Project*

: Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/04/15

Date of
Testing

Weight
(Kg)

01/06/15

8.215
8.270
8.240

Failure
Load
(kN)
1000
860
1060

Compressive
Strength (MPa)
44.44
38.22
47.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15396

Date: 03/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 01/06/15.

Project*

: Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/05/15

01/06/15

8.235
8.360
8.240

Failure
Load
(kN)
750
1030
760

Compressive
Strength (MPa)
33.33
45.78
33.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/06/15

Date of
Testing

Weight
(Kg)

11/06/15

7.875
7.970
8.040

Failure
Load
(kN)
400
540
480

Compressive
Strength (MPa)
17.78
24.00
21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Flaxmines Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

03/06/15

10/06/15

7.915
7.885
8.245

Failure
Load
(kN)
400
525
570

Compressive
Strength (MPa)
17.78
23.33
25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Aerator Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
03/06/15

Date of
Testing

Weight
(Kg)

10/06/15

7.885
7.915
7.875

Failure
Load
(kN)
450
525
400

Compressive
Strength (MPa)
20.00
23.33
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Intake well side.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/05/15

Date of
Testing

Weight
(Kg)

10/06/15

8.090
8.270
8.115

Failure
Load
(kN)
400
410
455

Compressive
Strength (MPa)
17.78
18.22
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: district.Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Jackwell Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

09/05/15

10/06/15

7.490
7.590
7.900

Failure
Load
(kN)
620
740
670

Compressive
Strength (MPa)
27.55
32.89
29.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25. Jack well side wall

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/05/15

10/06/15

7.825
7.540
7.820

Failure
Load
(kN)
430
395
480

Compressive
Strength (MPa)
19.11
17.55
21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25. MBR 2 Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

21/05/15

10/06/15

7.990
8.290
7.760

Failure
Load
(kN)
500
420
520

Compressive
Strength (MPa)
22.22
18.67
23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Jack well side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
14/05/15

Date of
Testing

Weight
(Kg)

10/06/15

8.310
8.084
8.045

Failure
Load
(kN)
420
415
585

Compressive
Strength (MPa)
18.67
18.44
26.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 2 Bracing Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/05/15

10/06/15

7.610
7.595
7.575

Failure
Load
(kN)
350
370
350

Compressive
Strength (MPa)
15.55
16.44
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Intake well Top Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

09/05/15

10/06/15

7.760
7.650
7.710

Failure
Load
(kN)
600
420
550

Compressive
Strength (MPa)
26.67
18.67
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Jackwell side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

25/05/15

10/06/15

7.595
7.535
7.480

200
200
190

8.89
8.89
8.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Flash Mixer Sidewall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

25/05/15

10/06/15

7.525
7.290

Failure
Load
(kN)
185
190

Compressive
Strength (MPa)
8.22
8.44

--

7.795

180

8.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/05/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

10/06/15

8.290
8.060
8.045

Failure
Load
(kN)
500
505
400

Compressive
Strength (MPa)
22.22
22.44
17.78

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Floculator Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/05/15

10/06/15

7.745
8.005
7.675

Failure
Load
(kN)
345
330
350

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
15.33
14.67
15.55

Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Flax mines Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

03/06/15

10/06/15

7.955
8.010
7.910

Failure
Load
(kN)
640
600
625

Compressive
Strength (MPa)
28.44
26.67
27.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 1 Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
12/05/15

Date of
Testing

Weight
(Kg)

10/06/15

7.755
7.940
7.850

Failure
Load
(kN)
310
350
350

Compressive
Strength (MPa)
13.78
15.55
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Intakewell side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
08/05/15

Date of
Testing

Weight
(Kg)

10/06/15

7.760
7.580
7.505

Failure
Load
(kN)
230
260
235

Compressive
Strength (MPa)
10.22
11.55
10.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 1 Bracing Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

01/05/15

10/06/15

8.040
7.985
7.970

Failure
Load
(kN)
490
450
500

Compressive
Strength (MPa)
21.78
20.00
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Jackwell Side Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
21/05/15

Date of
Testing

Weight
(Kg)

10/06/15

8.180
8.490
8.085

Failure
Load
(kN)
520
540
455

Compressive
Strength (MPa)
23.11
24.00
20.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Clarifloculator walkway slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
10/05/15

Date of
Testing

Weight
(Kg)

10/06/15

7.840
7.210
7.875

Failure
Load
(kN)
550
315
450

Compressive
Strength (MPa)
24.44
14.00
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Claurifloculator centre shaft wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/05/15

10/06/15

7.865
8.060
7.870

Failure
Load
(kN)
320
325
310

Compressive
Strength (MPa)
14.22
14.44
13.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, CWS sidewall

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/05/15

Date of
Testing

Weight
(Kg)

10/06/15

7.730
7.725
7.670

Failure
Load
(kN)
700
620
560

Compressive
Strength (MPa)
31.11
27.55
24.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15436

Date: 12/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/06/15.

Project*

: Proposed of Cauvery drinking water facilities to


Mavathur & 31 other villages of KR Nagar, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Filterbed Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

09/05/15

10/06/15

7.680
7.635
7.440

Failure
Load
(kN)
635
610
670

Compressive
Strength (MPa)
28.22
27.11
29.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15440

Date: 11/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/184 dated 03/06/15

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
730
720
730

Compressive
Strength (MPa)

1
D4
7.800
2
D5
06/05/15
10/06/15
8.060
3
D6
7.695
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

32.44
32.00
32.44

Testing officer

CRC No: 15451

Date: 17/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/214 dated 15/06/15

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Scooter Shed Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
630
700
600

Compressive
Strength (MPa)

1
F4
7.950
2
F5
18/05/15
15/06/15
8.310
3
F6
8.150
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

28.00
31.00
26.67

Testing officer

CRC No: 15463

Date: 18/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Mysore Diocesan Educational Society (Regd),


St. Josephs College Campus, Jayalakshmipuram,
Mysore-570012.

Ref No

: Letter dated 17/06/15

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

--

18/06/15

8.155
8.140
8.110

Failure
Load
(kN)
480
600
400

Compressive
Strength (MPa)
21.33
26.67
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15471

Date: 20/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Shivakumar, Gokulam Road, VV Mohalla, Mysore.

Ref No

: Letter dated 19/06/15

Project*

: Construction of Commercial Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

12/06/15

19/06/15

8.105

Failure
Load
(kN)
430

Compressive
Strength (MPa)
19.11

2
3

---

8.115
8.005

470
460

20.89
20.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15467

Date: 20/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 18/06/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Sump Tank 2nd layer wall concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
Date of
ID No.
No
Casting
1
-2
-11/06/15
3
--

: 150 mm x 150 mm x 150 mm


Date of
Weight
Failure Load
Testing
(Kg)
(kN)
8.050
510
18/06/15
8.160
510
8.150
455

Compressive
Strength (MPa)
22.67
22.67
20.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15467

Date: 20/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 18/06/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Sump 1st Layer wall concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
Date of
ID No.
No
Casting
1
-2
-10/06/15
3
--

: 150 mm x 150 mm x 150 mm


Date of
Weight
Failure Load
Testing
(Kg)
(kN)
8.040
405
18/06/15
8.195
510
7.960
520

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
18.00
22.67
23.11

Testing officer

CRC No: 15467

Date: 20/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 18/06/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Septic Tank Bed Concrete

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
Date of
ID No.
No
Casting
1
-2
-10/06/15
3
--

: 150 mm x 150 mm x 150 mm


Date of
Weight
Failure Load
Testing
(Kg)
(kN)
8.110
460
18/06/15
7.885
420
8.235
450

Compressive
Strength (MPa)
20.44
18.67
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15468

Date: 20/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysore division, Mysore.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 18/06/15

Project*

: Construction of New RTO Office, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
665
650
680

1
-7.805
21/05/15
18/06/15
2
-7.835
3
-7.745
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
29.55
28.89
30.22

Testing officer

CRC No: 15468

Date: 20/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysore division, Mysore.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 16/06/15.

Project*

: Construction of New RTO Office, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Plinth Beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
665
690
650

1
-7..765
19/05/15
18/06/15
2
-7.695
3
-7.675
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
30.44
30.67
28.89

Testing officer

CRC No: 15477

Date: 22/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M.S. Constructions, Railway Colony, Mysore.

Ref No

: Letter dated 20/06/15.

Project*

: Construction of Ideal Jawa Rotary School, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
935
920
810

1
-8.260
13/06/15
20/06/15
2
-8.280
3
-8.220
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
41.55
40.89
36.00

Testing officer

CRC No: 15472

Date: 22/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructure Pvt Ltd.

Ref No

: Letter dated 19/06/15.

Project*

: Construction of Varuna Residential Layout.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
360
450
350

1
-7.910
04/06/15
19/06/15
2
-8.085
3
-8.135
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.00
20.00
15.55

Testing officer

CRC No: 15482

Date: 24/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 22/06/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Column concrete Head Room.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
Date of
ID No.
No
Casting
1
-2
-15/06/15
3
--

: 150 mm x 150 mm x 150 mm


Date of
Weight
Failure Load
Testing
(Kg)
(kN)
8.445
150
22/06/15
7.815
270
7.935
150

Compressive
Strength (MPa)
6.66
12.0
6.66

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15482

Date: 24/06/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 22/06/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Sump Tank Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
Date of
ID No.
No
Casting
1
-2
-15/06/15
3
--

: 150 mm x 150 mm x 150 mm


Date of
Weight
Failure Load
Testing
(Kg)
(kN)
7.910
280
22/06/15
7.960
305
7.980
320

Compressive
Strength (MPa)
12.44
13.55
14.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15495

Date: 26/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: --

Project*

: Construction of SDM College, JLB Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/06/15

Date of
Testing

Weight
(Kg)

25/06/15

8.345
8.460
8.240

Failure
Load
(kN)
600
580
580

Compressive
Strength (MPa)
26.67
25.78
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15495

Date: 26/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: --

Project*

: Construction of SDM College, JLB Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

18/06/15

25/06/15

8.110
8230
8.490

Failure
Load
(kN)
450
415
435

Compressive
Strength (MPa)
20.00
18.44
19.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15494

Date: 26/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 25/06/15.

Project*

: Construction of CARP office complex at CAR Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Septic Tank Wall Concrete at Dormitory Block.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

17/06/15

25/06/15

Weight
(Kg)
8.205
8.200
8.355

Failure Load
(kN)
450
500
490

Compressive
Strength (MPa)
20.00
22.22
21.77

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15494

Date: 26/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client
Ref No
Project*
Source of Samples
Grade of Concrete*
Technical Reference
C/S Area of the specimen
Size of the Specimen

: EE, KSPHCL, Mysore.


: Letter dated 25/06/15.
: Construction of CARP office complex at CAR Mysore.
: Sample Supplied by the Client.
: M20, 2nd floor roof concrete at CARP Office Camplex.
: IS 516 1959 (Reaffirmed 2004)
: 22500 mm2
: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

ID No.

Date of
Casting

Date of
Testing

----------------

28/05/15

26/06/15

Weight
(Kg)
8.020
8.110
7.470
8.310
8.300
8.185
8.290
8.580
7.990
8.175
8.335
8.015
8.435
8.370
8.375

Failure Load
(kN)
680
665
780
800
760
680
635
690
660
690
730
720
700
750
615

Compressive
Strength (MPa)
30.22
29.55
34.67
35.55
33.78
30.22
28.22
30.67
29.33
30.66
32.44
32.00
31.11
33.33
27.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15499

Date: 27/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/246 dated 26/06/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, GF Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
550
540
590

Compressive
Strength (MPa)

1
H1
8.395
2
H2
19/06/15
26/06/15
8.325
3
H3
8.175
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

24.44
24.00
26.22

Testing officer

CRC No: 15498

Date: 27/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/247 dated 26/06/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, GF Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
510
585
560

1
G1
8.240
2
G2
19/06/15
26/06/15
8.375
3
G3
8.230
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.67
26.00
24.89

Testing officer

CRC No: 15497

Date: 27/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Rotary School, Mysore.

Ref No

: Letter dated 26/06/15.

Project*

: Construction of Rotary School, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

19/06/15

26/06/15

Weight
(Kg)
8.200
8.330
8.325

Failure Load
(kN)
760
840
800

Compressive
Strength (MPa)
33.78
37.33
35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15496

Date: 27/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: H. Umesh, Dristi Enclave, Vijayanagar IV Stage, Mysore.

Ref No

: Letter dated 26/06/15.

Project*

: Residential Purpose.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1

ID No.
--

Date of
Casting
18/06/15

Date of
Testing
26/06/15

Weight
(Kg)
8.085

Failure Load
(kN)
320

Compressive
Strength (MPa)
14.22

2
3

---

8.130
8.015

310
380

13.77
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15489

Date: 30/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Government Employees House Building Co-operative Society


Ltd., Mysore.

Ref No

: Letter dated 23/06/15.

Project*

: Construction of O.H.T. of Capacity 5 lakh litres at


Vishakanagar Yadahalli Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2

ID No.
---

Date of
Casting
23/06/15

Date of
Testing
30/06/15

Weight
(Kg)
8.180
8.140

Failure Load
(kN)
370
365

Compressive
Strength (MPa)
16.44
16.22

--

8.185

405

18.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15501

Date: 29/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/06/15.

Project*

: Cauvery drinking water facilities to Mavathur


& 31 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Wash water tank columns.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/06/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

27/06/15

7.880
7.925
8.100

Failure
Load
(kN)
220
265
250

Compressive
Strength (MPa)
9.78
11.78
11.11

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15501

Date: 29/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/06/15.

Project*

: Cauvery drinking water facilities to Mavathur


& 31 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR. 01 Columns.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/06/15

Date of
Testing

Weight
(Kg)

27/06/15

7.715
7.790
7.855

Failure
Load
(kN)
250
285
200

Compressive
Strength (MPa)
11.11
12.67
8.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15501

Date: 29/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/06/15.

Project*

: Cauvery drinking water facilities to Malanayakanahalli


& 41 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Clarifloculator Centershaft side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/06/15

27/06/15

7.770
7.890
7.765

Failure
Load
(kN)
250
215
220

Compressive
Strength (MPa)
11.11
9.55
9.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15501

Date: 29/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/06/15.

Project*

: Cauvery drinking water facilities to Malanayakanahalli


& 41 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR I Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/06/15

Date of
Testing

Weight
(Kg)

27/06/15

7.850
7.985
8.040

Failure
Load
(kN)
270
235
310

Compressive
Strength (MPa)
12.00
10.44
13.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15501

Date: 29/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/06/15.

Project*

: Cauvery drinking water facilities to Malanayakanahalli


& 41 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR I Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/06/15

Date of
Testing

Weight
(Kg)

27/06/15

7.750
8.055
8.040

Failure
Load
(kN)
230
240
240

Compressive
Strength (MPa)
10.22
10.67
10.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15501

Date: 29/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/06/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 other


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Rapid sand filter side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/05/15

Date of
Testing

Weight
(Kg)

27/06/15

7.580
7.685
7.725

Failure
Load
(kN)
420
370
305

Compressive
Strength (MPa)
18.67
16.44
13.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15501

Date: 29/06/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/06/15.

Project*

: Cauvery drinking water facilities to Malanayakanahalli and


other 41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Clarifloculator Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

19/06/15

27/06/15

7.980
8.010
8.175

Failure
Load
(kN)
350
300
215

Compressive
Strength (MPa)
15.55
13.33
9.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15501

Date: 29/06/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 27/06/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 other


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR. 01 Bracing beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
21/05/15

Date of
Testing

Weight
(Kg)

27/06/15

7.805
7.870
7.955

Failure
Load
(kN)
400
500
555

Compressive
Strength (MPa)
17.78
22.22
24.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15515

Date: 01/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 30/06/15

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/06/15

27/06/15

8.000
7.970
7.870

Failure
Load
(kN)
270
280
280

Compressive
Strength (MPa)
12.00
12.44
12.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15515

Date: 01/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 30/06/15

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/06/15

Date of
Testing

Weight
(Kg)

27/06/15

8.005
7.770
8.040

Failure
Load
(kN)
400
350
350

Compressive
Strength (MPa)
17.78
15.55
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15508

Date: 02/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Rotary School, Mysore.

Ref No

: Letter dated 30/06/15.

Project*

: Construction of Rotary School, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

22/06/15

30/06/15

Weight
(Kg)
8.265
8.260
8.160

Failure Load
(kN)
900
985
920

Compressive
Strength (MPa)
40.00
43.78
40.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15520

Date: 03/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Royal Concorde International School, Bogadi, Mysore.

Ref No

: Letter dated 02/07/15.

Project*

: Construction of Royale Concorde International School.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, GF Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

02/06/15

02/07/15

Weight
(Kg)
8.240
8.255
8.330

Failure Load
(kN)
820
1170
940

Compressive
Strength (MPa)
36.44
52.00
41.77

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15524

Date: 06/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 04/07/15

Project*

: Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/06/15

04/07/15

8.350
8.325
8.350

Failure
Load
(kN)
820
1000
875

Compressive
Strength (MPa)
36.44
44.44
38.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15525

Date: 06/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 04/07/15

Project*

: Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/06/15

Date of
Testing

Weight
(Kg)

04/07/15

8.260
8.210
8.310

Failure
Load
(kN)
975
810
815

Compressive
Strength (MPa)
43.33
36.00
32.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15523

Date: 06/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/15 dated 02/07/15.

Project*

: Construciton of Mobilization Hall (35 beds) for RPF Staff


at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Plinth Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/06/15

03/07/15

7.845
7.735
7.840

Failure
Load
(kN)
390
385
390

Compressive
Strength (MPa)
17.33
17.11
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15523

Date: 06/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/15 dated 02/07/15.

Project*

: Construciton of Mobilization Hall (35 beds) for RPF Staff


at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Plinth Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/06/15

Date of
Testing

Weight
(Kg)

03/07/15

7.810
7.780
7.750

Failure
Load
(kN)
400
380
390

Compressive
Strength (MPa)
17.78
16.89
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15523

Date: 06/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/15 dated 02/07/15.

Project*

: Construciton of Mobilization Hall (35 beds) for RPF Staff


at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Plinth Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/06/15

03/07/15

7.830
7.410
7.970

Failure
Load
(kN)
400
395
390

Compressive
Strength (MPa)
17.78
17.55
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15523

Date: 06/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/15 dated 02/07/15.

Project*

: Construciton of Mobilization Hall (35 beds) for RPF Staff


at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

04/06/15

03/07/15

7.605
7.600
7.675

600
590
600

26.67
26.22
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15523

Date: 06/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/15 dated 02/07/15.

Project*

: Construciton of Mobilization Hall (35 beds) for RPF Staff


at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

05/06/15

03/07/15

7.840

Failure
Load
(kN)
585

Compressive
Strength (MPa)
26.00

2
3

---

7.015
7.575

590
590

26.22
26.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15523

Date: 06/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/15 dated 02/07/15.

Project*

: Construciton of Mobilization Hall (35 beds) for RPF Staff


at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
06/06/15

Date of
Testing

Weight
(Kg)

03/07/15

7.725
7.925
7.595

Failure
Load
(kN)
600
600
600

Compressive
Strength (MPa)
26.67
26.67
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15534

Date: 08/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Bangalore.

Ref No

: Letter dated 07/07/15.

Project*

: Kuberanand Sagara Layout, Maidanahalli village Road,


Yelwala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Road Culvert.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/06/15

Date of
Testing

Weight
(Kg)

07/07/15

7.990
8.100
7.950

Failure
Load
(kN)
300
340
250

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
13.33
15.11
11.11

Testing officer

CRC No: 15533

Date: 08/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RNR Construciton (P) Limited.

Ref No

: Letter dated 07/07/15.

Project*

: RMSA, Malavalli.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 2nd Floor Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

30/06/15

07/07/15

8.050
8.000
8.050

Failure
Load
(kN)
380
380
410

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.89
16.89
18.22

Testing officer

CRC No: 15538

Date: 08/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RFO, Wild Life Zone, KFD, Veeranahosahalli.

Ref No

: Letter No. RFO/WL/VH/101/2015-16 dated 06/07/15.

Project*

: Construction of Railway Barricade at Veeranahosahalli Wild


Life Zone, Rajiv Gandhi National Park
(Fencing to restrict Wild Elephant).

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/06/15

07/07/15

7.556
7.605
7.545

Failure
Load
(kN)
400
425
360

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
17.78
18.89
16.00

3. Any correction invalidates this report.

Testing officer

CRC No: 15542

Date: 09/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal industrial Area, Mysore.

Ref No

: Letter dated 08/07/15.

Project*

: Damden Solarium, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Block 5 seventh floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

10/06/15

08/07/15

8.085
8.085
7.905

Failure
Load
(kN)
430
520
525

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
19.11
23.11
23.33

Testing officer

CRC No: 15552

Date: 10/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/282 dated 07/07/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Above F2 level second lift column raising concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
550
570
460

1
FC-1
7.720
2
FC-2
02/07/15
09/07/15
7.590
3
FC-3
8.250
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
24.44
25.33
20.44

Testing officer

CRC No: 15556

Date: 11/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Bangalore.

Ref No

: Letter dated 11/7/15.

Project*

: Kuberanand Sagara Layout, Maidanahalli village Road,


Yelwala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Culvert.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

25/06/15

10/07/15

8.235
8.145
8.360

Failure
Load
(kN)
570
610
500

Compressive
Strength (MPa)
25.33
27.11
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15537

Date: 09/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 07/07/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, F flooring in basement floor (south side).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
01/07/15

Date of
Testing

Weight
(Kg)

08/07/15

8.020
8.030
8.095

Failure
Load
(kN)
425
425
390

Compressive
Strength (MPa)
18.89
18.9
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15537

Date: 09/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 07/07/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, F flooring in basement floor (south side).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/06/15

Date of
Testing

Weight
(Kg)

08/07/15

8.145
8.015
7.910

Failure
Load
(kN)
400
385
390

Compressive
Strength (MPa)
17.78
17.11
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15568

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/P. Way/KRNR.

Ref No

: Letter No. SSE/P.Way/KRNR dated 04/07/2015.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
construction of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
820
830
830
910
890
900
850
850
860
900
900
880

1
-8.150
2
-02/06/15
28/06/15
8.200
3
-8.095
1
-8.100
2
-05/06/15
04/07/15
8.120
3
-8.300
1
-8.320
2
-09/06/15
07/07/15
8.280
3
-8.080
1
-8.260
2
-11/06/15
09/07/15
8.210
3
-8.170
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
36.44
36.89
36.89
40.44
39.55
40.00
37.78
37.78
38.22
40.00
40.00
39.11

Testing officer

CRC No: 15564

Date: 13/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 11/07/15.

Project*

: Proposed Layout at Athmanand Sagara.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/07/15

Date of
Testing

Weight
(Kg)

11/07/15

7.740
7.550
7.780

Failure
Load
(kN)
725
700
665

Compressive
Strength (MPa)
32.22
31.11
29.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15569

Date: 14/07/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Rotary School, Mysore.

Ref No

: Letter dated 13/07/15.

Project*

: Process of Ideal Jawa Rotary School, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Plinth casting.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

15/06/15

13/07/15

Weight
(Kg)
8.330
8.180
8.220

Failure Load
(kN)
1050
1020
850

Compressive
Strength (MPa)
46.67
45.33
37.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Pipe gallery side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/07/15

Date of
Testing

Weight
(Kg)

13/07/15

8.045
7.270
7.820

Failure
Load
(kN)
320
290
270

Compressive
Strength (MPa)
14.22
12.89
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Wash water tank bracing beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

13/06/15

13/07/15

8.020
7.945
8.025

Failure
Load
(kN)
475
320
500

Compressive
Strength (MPa)
21.11
14.22
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages

of K.R. Nagar Taluk, Mysore district.


Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Aerator Centre Shaft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/06/15

Date of
Testing

Weight
(Kg)

13/07/15

7.895
8.020
8.350

Failure
Load
(kN)
450
480
500

Compressive
Strength (MPa)
20.00
21.33
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Aerator column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/06/15

Date of
Testing

Weight
(Kg)

13/07/15

7.535
7.855
7.995

Failure
Load
(kN)
570
565
500

Compressive
Strength (MPa)
25.33
25.11
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Jackwell walkway slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

14/06/15

13/07/15

7.540
7.660
7.680

Failure
Load
(kN)
470
455
420

Compressive
Strength (MPa)
20.89
20.22
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Aerator Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3

----

: 150 mm x 150 mm x 150 mm


Date of
Casting
14/06/15

Date of
Testing

Weight
(Kg)

13/07/15

7.650
7.920
7.600

Failure
Load
(kN)
500
420
550

Compressive
Strength (MPa)
22.22
18.67
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 01 bracing beam 4.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/07/15

13/07/15

7.680
7.710
7.880

Failure
Load
(kN)
220
220
230

Compressive
Strength (MPa)
9.78
9.78
10.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Wash water column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

16/06/15

13/07/15

7.750
7.705
7.645

530
450
570

23.55
20.00
25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Jack well side wall above girder.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

17/06/15

13/07/15

7.800
8.040

Failure
Load
(kN)
370
410

Compressive
Strength (MPa)
16.44
18.22

--

7.790

280

12.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15570

Date: 14/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/07/15

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 01, Column above bracing beam 2.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/06/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

13/07/15

7.760
7.685
7.900

Failure
Load
(kN)
450
560
400

Compressive
Strength (MPa)
20.00
24.89
17.78

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15579

Date: 15/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Bangalore.

Ref No

: Letter dated 14/7/15.

Project*

: Shreesha Hill View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

06/07/15

14/07/15

7.310
7.400
7.325

Failure
Load
(kN)
200
230
250

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
8.89
10.22
11.11

Testing officer

CRC No: 15586

Date: 16/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysore Division, Mysuru.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 15/07/15.

Project*

: Construction of New RTO Office, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
450
475
470

1
-8.205
08/07/15
16/07/15
2
-8.310
3
-8.195
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
20.00
21.11
20.89

3. Any correction invalidates this report.

Testing officer

CRC No: 15558


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Assistant Division Engineer, SWR, Mysore.

Ref No

: Letter Y/W 148/1/3405 dated 19/06/15.

Project*

: MYS-ASK section : - Elimination of manned level crossing


No. 15 @ Km. 17/800-900 by construction of road over
bridge.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M45, PSC Girder 2

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/06/15

10/07/15

7.795
8.010
8.030

Failure
Load
(kN)
700
750
750

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
31.11
33.33
33.33

Testing officer

CRC No: 15558


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Assistant Division Engineer, SWR, Mysore.

Ref No

: Letter Y/W 148/1/3405 dated 25/06/15.

Project*

: MYS-ASK section : - Elimination of manned level crossing


No. 15 @ Km. 17/800-900 by construction of road over
bridge.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M45, PSC Girder 3

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

18/06/15

10/07/15

8.080
7.860
8.045

Failure
Load
(kN)
820
695
700

Compressive
Strength (MPa)
36.44
30.89
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15558


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Assistant Division Engineer, SWR, Mysore.

Ref No

: Letter Y/W 148/1/3405 dated 15/06/15.

Project*

: MYS-ASK section : - Elimination of manned level crossing


No. 15 @ Km. 17/800-900 by construction of road over
bridge.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M45, PSC Girder 1

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
08/06/15

Date of
Testing

Weight
(Kg)

10/07/15

8.085
7.805
8.670

Failure
Load
(kN)
800
710
690

Compressive
Strength (MPa)
35.56
31.55
30.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15606

Date: 22/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Royal Concorde International School, Bogadi, Mysore.

Ref No

: Letter dated 21/07/15.

Project*

: Construction of Royale Concorde International School.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, GF Concrete Roof

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

12/07/15

21/07/15

Weight
(Kg)
7.920
7.915
7.975

Failure Load
(kN)
420
385
440

Compressive
Strength (MPa)
18.67
17.11
19.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15630

Date: 28/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal industrial Area, Mysore.

Ref No

: Letter dated 27/07/15.

Project*

: Damden Solarium, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Roof Slab, Block 5.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/07/15

27/07/15

8.030
7.960
8.105

Failure
Load
(kN)
260
250
375

Compressive
Strength (MPa)
11.55
11.11
16.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15635

Date: 29/07/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: Royal Concorde International School, Bogadi, Mysore.

Ref No

: Letter dated 28/07/15.

Project*

: Construction of Royale Concorde International School.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, First Floor Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
Date of
Date of
Weight
Failure Load
ID No.
No
Casting
Testing
(Kg)
(kN)
1
-8.175
450
2
-18/07/15
28/07/15
8.270
515
3
-8.265
480
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.00
22.89
21.33

Testing officer

CRC No: 15634

Date: 29/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/15 dated 23/07/15.

Project*

: Mysuru- Construciton of Mobilization Hall (35 beds) for


RPF Staff

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Plinth Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/06/15

28/07/15

7.705
7.805
7.705

Failure
Load
(kN)
670
700
680

Compressive
Strength (MPa)
29.78
31.11
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15634

Date: 29/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/15 dated 23/07/15.

Project*

: Mysuru- Construciton of Mobilization Hall (35 beds) for


RPF Staff

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Plinth Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/06/15

28/07/15

7.735
7.640
7.960

Failure
Load
(kN)
660
680
680

Compressive
Strength (MPa)
29.33
30.22
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15634

Date: 29/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/15 dated 23/07/15.

Project*

: Mysuru- Construciton of Mobilization Hall (35 beds) for


RPF Staff

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Plinth Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
26/06/15

Date of
Testing

Weight
(Kg)

28/07/15

7.750
7.455
7.665

Failure
Load
(kN)
700
670
670

Compressive
Strength (MPa)
31.11
29.78
29.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15641

Date: 31/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 29/07/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
21/07/15

Date of
Testing

Weight
(Kg)

29/07/15

7.975
7.995
7.700

Failure
Load
(kN)
300
310
200

Compressive
Strength (MPa)
13.33
13.78
8.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15699

Date: 17/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 14/08/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

06/08/15

14/08/15

8.050
7.360
7.750

Failure
Load
(kN)
300
210
260

Compressive
Strength (MPa)
13.33
9.33
11.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15651

Date: 31/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 30/07/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, (MSR Concrete) West side basement floor


VDF concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3
4
5
6

-------

: 150 mm x 150 mm x 150 mm


Date of
Casting

03/07/15

Date of
Testing

Weight
(Kg)

30/07/15

8.105
8.065
8.105
8.065
8.055
8.070

Failure
Load
(kN)
640
620
660
650
620
655

Compressive
Strength (MPa)
28.44
27.55
29.33
28.89
27.55
29.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15639

Date: 31/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysuru Division, Mysuru.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 28/07/15

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column concrete (Ground Floor).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
460
430
450

Compressive
Strength (MPa)

1
-8.240
20/07/15
29/07/15
2
-8.245
3
-8.165
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

20.44
19.11
20.00

Testing officer

CRC No: 15652

Date: 31/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 390/SW/MYS/15 dated 29/05/15.

Project*

: Mysuru-Improvements to Watering arrangements at Station,


(Contruction of Over Head Tank at Mysuru).

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Main Shaft Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

21/05/15

30/07/15

7.715
7.710
--

360
400
--

16.00
17.78
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15652

Date: 31/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 390/SW/MYS/15 dated 29/05/15.

Project*

: Mysuru-Improvements to Watering arrangements at Station,


(Contruction of Over Head Tank at Mysuru).

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Main Shaft Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

18/06/15

30/07/15

7.525
7.685
--

330
390
--

14.67
17.33
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15652

Date: 31/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 390/SW/MYS/15 dated 29/05/15.

Project*

: Mysuru-Improvements to Watering arrangements at Station,


(Contruction of Over Head Tank at Mysuru).

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Main Shaft Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

13/07/15

30/07/15

7.890
7.950

Failure
Load
(kN)
500
450

Compressive
Strength (MPa)
22.22
20.00

--

--

--

--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15647

Date: 30/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/332 dated 30/07/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, FF Column Cincrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

FC4

02/07/15

30/07/15

8.310

Failure
Load
(kN)
780

Compressive
Strength (MPa)
35.67

2
FC5
8.095
760
3
FC6
8.340
760
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

33.78
33.78

Testing officer

CRC No: 15648

Date: 30/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/333 dated 30/07/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F3 Level Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
J1
2
J2
23/07/15
30/07/15
3
J3
1.* Information furnished by the client.

Weight
(Kg)
8.635
8.400
8.550

Failure
Load
(kN)
620
650
650

Compressive
Strength (MPa)
27.56
28.89
28.89

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15649

Date: 30/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/334 dated 30/07/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F3 Level Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
600
620
590

1
K1
8.145
2
K2
23/07/15
30/07/15
8.195
3
K3
7.955
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
26.67
27.56
26.22

Testing officer

CRC No: 15650

Date: 31/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: NCCl, Mysore.

Ref No

: Letter dated 30/07/15.

Project*

: Construction of New Government Buildings-Strengthening of


existing Government Secondary School in Mysore districtCATEGORY B Hirehalli Site (Type -01), HD Kote (TQ),
Mysore (DT)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: First Floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
350
300
280

1
-8.215
2
-21/06/15
30/07/15
7.930
3
-8.180
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
15.55
13.33
12.44

Testing officer

CRC No: 15650

Date: 31/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: NCCl, Mysore.

Ref No

: Letter dated 30/07/15.

Project*

: Construction of New Government Buildings-Strengthening of


existing Government Secondary School in Mysore districtCATEGORY B Thumbasoge Site (Type -53),
HD Kote (TQ), Mysore (DT)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Ground Floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
170
250
150

1
-7.945
2
-02/07/15
30/07/15
8.130
3
-7.450
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
7.55
11.11
6.66

Testing officer

CRC No: 15658

Date: 03/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Mysore Diocesan Educational Society (Regd),


St. Josephs College Campus, Jayalakshmipuram,
Mysore-570012.

Ref No

: Letter dated 31/07/15.

Project*

: MDES. sT. Joseph School, JL Puram, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

--

31/07/15

8.150
8.295
8.275

Failure
Load
(kN)
500
520
545

Compressive
Strength (MPa)
22.22
23.11
24.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15653

Date: 03/08/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 31/07/15

Project*

: SDM College, JLB Road, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/07/15

Date of
Testing

Weight
(Kg)

31/07/15

7.770
7.890
7.950

Failure
Load
(kN)
420
500
450

Compressive
Strength (MPa)
18.67
22.22
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15659

Date: 03/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 01/08/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, (MSR Concrete), Retainning wall Exit.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/07/15

03/08/15

8.080
8.205
8.285

Failure
Load
(kN)
690
700
700

Compressive
Strength (MPa)
30.67
31.11
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15660

Date: 03/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Nirman Promoters, Mysore.

Ref No

: Letter dated 01/08/15.

Project*

: Kalpavruksha Kshetra Sri. Raghavendra Swamy Mutt,


Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/07/15

01/08/15

8.250
8.210
8.205

Failure
Load
(kN)
480
470
450

Compressive
Strength (MPa)
21.33
20.89
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15664

Date: 06/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 05/08/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
28/07/15

Date of
Testing

Weight
(Kg)

05/08/15

8.005
8.200
7.960

Failure
Load
(kN)
350
495
400

Compressive
Strength (MPa)
15.55
22.00
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15665

Date: 06/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/348 dated 05/08/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical

installations, drainage, external water supply lines approach


path way and c/o one scooter shed for 8 nos scooters.
Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column Concrete F4 level. 4.85 cum.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
400
450
470

Compressive
Strength (MPa)

1
L1
7.890
2
L2
29/07/15
05/08/15
7.900
3
L3
8.065
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

17.78
20.00
20.89

Testing officer

CRC No: 15666

Date: 07/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysuru Division, Mysuru.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bengaluru.

Ref No

: Letter dated 05/08/15

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab Concrete (Lower Ground Floor).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
650
710
630

1
-8.245
08/07/15
06/08/15
2
-8.200
3
-8.280
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
28.89
31.55
28.00

Testing officer

CRC No: 15674

Date: 10/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 08/08/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

31/07/15

08/08/15

7.805
7.830
7.860

Failure
Load
(kN)
155
150
270

Compressive
Strength (MPa)
6.89
6.67
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15674

Date: 10/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 08/08/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

11/07/15

08/08/15

7.750
7.820
8.280

520
560
550

23.11
24.89
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15675

Date: 10/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 08/08/15

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Stair Case.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

01/08/15

08/08/15

7.870
7.765
7.660

365
350
615

16.22
15.55
27.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15675

Date: 10/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 08/08/15

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

29/07/15

08/08/15

7.775
7.680

Failure
Load
(kN)
490
350

Compressive
Strength (MPa)
21.78
15.55

--

8.045

380

16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15678

Date: 12/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 10/08/15.

Project*

: Shreesha Hill View.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/07/15

10/08/15

8.030
7.970
7.800

Failure
Load
(kN)
410
415
420

Compressive
Strength (MPa)
18.22
18.44
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15686

Date: 12/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: The Manager (Civil Maintainance), BMEL, Mysore Complex.

Ref No

: Letter dated 11/08/15.

Project*

: Construction of providing foundation work and room for


manifold area in connection with the installation of the 20 KL
liquid Argon vessel of equipement division, BEML, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/07/15

Date of
Testing

Weight
(Kg)

11/08/15

7.929
8.000
8.100

Failure
Load
(kN)
470
475
460

Compressive
Strength (MPa)
20.89
21.11
20.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15677

Date: 11/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/08/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Top Roof Slab (Staff quarters)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/08/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

10/08/15

7.560
7.810
7.860

Failure
Load
(kN)
180
175
170

Compressive
Strength (MPa)
8.0
7.78
7.55

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15677

Date: 11/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/08/15.

Project*

: Cauvery drinking water facilities to Mallanayakanahalli and


39 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF inlet channel slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/07/15

10/08/15

8.140
7.965
7.825

Failure
Load
(kN)
170
185
150

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
7.55
8.22
6.67

Testing officer

CRC No: 15677

Date: 11/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/08/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR-01 columns above brace beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
10/07/15

Date of
Testing

Weight
(Kg)

10/08/15

7.985
7.715
8.065

Failure
Load
(kN)
430
350
405

Compressive
Strength (MPa)
19.11
15.55
18.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15677

Date: 11/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/08/15.

Project*

: Cauvery drinking water facilities to Mallanayakanahalli and


39 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Filter bed channel.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/07/15

Date of
Testing

Weight
(Kg)

10/08/15

8.205
8.045
8.065

Failure
Load
(kN)
250
310
315

Compressive
Strength (MPa)
11.11
13.78
14.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15677

Date: 11/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/08/15.

Project*

: Cauvery drinking water facilities to Mallanayakanahalli and


39 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Aerator side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/07/15

10/08/15

8.160
8.260
8.110

Failure
Load
(kN)
250
255
270

Compressive
Strength (MPa)
11.11
11.33
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15677

Date: 11/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/08/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Wash water tank columns.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
11/07/15

Date of
Testing

Weight
(Kg)

10/08/15

7.870
8.440
7.670

Failure
Load
(kN)
600
690
445

Compressive
Strength (MPa)
26.67
30.67
19.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15677

Date: 11/08/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/08/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pure water channel Top Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

11/07/15

10/08/15

7.930
7.845
7.790

Failure
Load
(kN)
860
790
720

Compressive
Strength (MPa)
38.22
35.11
32.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15677

Date: 11/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/08/15.

Project*

: Cauvery drinking water facilities to Mallanayakanahalli and


39 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/07/15

10/08/15

8.010
8.235
8.050

Failure
Load
(kN)
350
280
290

Compressive
Strength (MPa)
15.55
12.44
12.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15677

Date: 11/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 10/08/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Jack Well side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

10/07/15

10/08/15

7.655
7.850
7.900

Failure
Load
(kN)
460
460
450

Compressive
Strength (MPa)
20.44
20.44
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15685

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, KRIES, Chamarajanagar.

Agency

: N.B. Construction Company.

Ref No

: Letter dated 11/08/15.

Project*

: M.D.R.S at Hangala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, C.C. Road.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

14/07/15

11/08/15

8.120
7.910
8.090

Failure
Load
(kN)
550
550
540

Compressive
Strength (MPa)
24.44
24.44
24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15685

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, KRIES, Chamarajanagar.

Agency

: N.B. Construction Company.

Ref No

: Letter dated 11/08/15.

Project*

: M.D.R.S at Hangala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, C.C. Road.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
14/07/15

Date of
Testing

Weight
(Kg)

11/08/15

8.120
8.215
8.340

Failure
Load
(kN)
560
540
570

Compressive
Strength (MPa)
24.89
24.00
25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15685

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, KRIES, Chamarajanagar.

Agency

: N.B. Construction Company.

Ref No

: Letter dated 11/08/15.

Project*

: M.D.R.S at Hangala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, C.C. Road.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

15/07/15

11/08/15

8.185
8.120
8.300

Failure
Load
(kN)
575
565
580

Compressive
Strength (MPa)
25.56
25.11
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15685

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, KRIES, Chamarajanagar.

Agency

: N.B. Construction Company.

Ref No

: Letter dated 11/08/15.

Project*

: MDRS at Hangala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Basket Ball court.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3

----

: 150 mm x 150 mm x 150 mm


Date of
Casting
14/07/15

Date of
Testing

Weight
(Kg)

11/08/15

8.100
8.105
8.290

Failure
Load
(kN)
490
510
525

Compressive
Strength (MPa)
21.78
22.67
23.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15685

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, KRIES, Chamarajanagar.

Agency

: N.B. Construction Company.

Ref No

: Letter dated 11/08/15.

Project*

: M.D.R.S at Hangala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, C.C. Drain.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

13/07/15

11/08/15

8.375
8.250
8.225

Failure
Load
(kN)
480
490
490

Compressive
Strength (MPa)
21.33
21.78
21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15685

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, KRIES, Chamarajanagar.

Agency

: N.B. Construction Company.

Ref No

: Letter dated 11/08/15.

Project*

: M.D.R.S at Hangala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, C.C. Drain.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

15/07/15

11/08/15

8.060
7.645
7.145

520
515
530

23.11
22.89
23.56

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15685

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, KRIES, Chamarajanagar.

Agency

: N.B. Construction Company.

Ref No

: Letter dated 11/08/15.

Project*

: K.R.C.R.S @ Begur.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Basket ball court.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

14/07/15

11/08/15

7.955
8.015

Failure
Load
(kN)
525
540

Compressive
Strength (MPa)
23.33
24.00

--

7.835

535

23.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15693

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, JNNURM, MCC, Mysore.

Ref No

: Letter No. MCC/JNNURM/AEE-4//2011-12 dated 12/08/15.

Project*

: Multi level parking Raft concrete in Town hall premises.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/08/15

Date of
Testing

Weight
(Kg)

12/08/15

7.745
7.770
7.755

Failure
Load
(kN)
180
175
200

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
8.0
7.78
8.89

Testing officer

CRC No: 15689

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 12/08/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

15/07/15

12/08/15

7.930
8.145
8.115

Failure
Load
(kN)
500
520
450

Compressive
Strength (MPa)
22.22
23.11
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15690

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 12/08/15.

Project*

: Construciton of CARP Office Complex @ CAR, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, CARP Office Complex Head Room Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

8.050

Failure
Load
(kN)
550

--

8.045

420

18.67

--

7.850

520

23.11

--

8.275

590

26.22

--

8.125

400

17.78

--

7.925

430

19.11

Date of
Casting

28/07/15

Date of
Testing

12/08/15

Weight
(Kg)

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
24.44

3. Any correction invalidates this report.


Testing officer

CRC No: 15690

Date: 13/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: EE, KSPHCL, Mysore.

Ref No

: Letter dated 12/08/15.

Project*

: Construciton of CARP Office Complex @ CAR, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Septic Tank Roof Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

7.950

Failure
Load
(kN)
530

--

8.145

600

26.67

--

8.290

615

27.33

--

8.145

680

30.22

--

8.010

520

23.11

--

7.975

635

28.22

Date of
Casting

20/07/15

1.* Information furnished by the client.

Date of
Testing

12/08/15

Weight
(Kg)

Compressive
Strength (MPa)
23.55

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15696

Date: 14/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, JNNURM, MCC, Mysore.

Ref No

: Letter No. MCC/JNNURM/AEE-4//2011-12 dated 13/08/15.

Project*

: Multi level parking at Town hall premises.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing F-5, F-6 & F-9 between Grid No. 17, 18 19.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
06/08/15

Date of
Testing

Weight
(Kg)

13/08/15

7.950
8.055
7.980

Failure
Load
(kN)
225
210
225

Compressive
Strength (MPa)
10.00
9.33
10.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15703

Date: 17/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MS Construction, Mysore.

Ref No

: Letter dated 14/08/15.

Project*

: Ideal Jawa Rotary School.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Roof.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

17/07/15

14/08/15

8.250
8.070
8.240

Failure
Load
(kN)
830
915
820

Compressive
Strength (MPa)
36.89
40.67
36.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15711

Date: 18/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 17/08/15

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

10/08/15

17/08/15

8.030
8.145
7.960

Failure
Load
(kN)
440
460
385

Compressive
Strength (MPa)
19.55
20.44
17.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15715

Date: 18/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Secretary, Mysore Diocesan Educational Society (Regd),


Jayalakshmipuram, Mysore.

Ref No

: Letter dated 17/08/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
550
700
850

1
-8.260
-17/08/15
2
-8.140
3
-8.215
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
24.44
31.11
37.78

Testing officer

CRC No: 15722

Date: 20/08/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 19/08/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

11/08/15

19/08/15

7.850
7.810
8.065

Failure
Load
(kN)
260
370
360

Compressive
Strength (MPa)
11.55
16.44
16.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15722

Date: 20/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 19/08/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
21/08/15

Date of
Testing

Weight
(Kg)

19/08/15

7.980
7.945
8.060

Failure
Load
(kN)
520
575
400

Compressive
Strength (MPa)
23.11
25.55
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15724

Date: 20/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SNR Associates, Mysore.

Ref No

: Letter dated 19/08/15.

Project*

: Construction of Museum at Suttur,

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
11/08/15

Date of
Testing

Weight
(Kg)

19/08/15

8.155
8.130
7.980

Failure
Load
(kN)
310
355
280

Compressive
Strength (MPa)
13.78
15.78
12.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15724

Date: 20/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SNR Associates, Mysore.

Ref No

: Letter dated 19/08/15.

Project*

: Construction of Museum at Suttur,

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/08/15

19/08/15

7.690
7.810
7.800

Failure
Load
(kN)
385
350
335

Compressive
Strength (MPa)
17.11
15.55
14.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15489

Date: 21/07/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Government Employees House Building Co-operative Society


Ltd., Mysore.

Ref No

: Letter dated 23/06/15.

Project*

: Construction of O.H.T. of Capacity 5 lakh litres at


Vishakanagar Yadahalli Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

23/06/15

21/07/15

Weight
(Kg)
8.190
8.200
8.210

Failure Load
(kN)
550
530
550

Compressive
Strength (MPa)
24.44
23.56
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15735

Date: 24/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysuru Division, Mysuru.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 21/08/15.

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, G.F. Slab concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
545
470
450

1
-8.010
14/08/15
21/08/15
2
-8.180
3
-8.210
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
24.22
20.89
20.00

Testing officer

CRC No: 15725

Date: 21/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Range Forest Officer, Veerana Hosahalli.

Ref No

: Letter dated 20/08/15.

Project*

: Construction of Elephant Restriction fence using Rail Railings


in Wild Life Zone, Veeranahosahalli, Rajiv Gandhi National
Park.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

29/07/15

20/08/15

Weight
(Kg)
7.435
7.600
--

Failure Load
(kN)
460
550
--

Compressive
Strength (MPa)
20.44
24.44
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15725

Date: 21/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Range Forest Officer, Veerana Hosahalli.

Ref No

: Letter dated 20/08/15.

Project*

: Construction of Elephant Restriction fence using Rail Railings


in Wild Life Zone, Veeranahosahalli, Rajiv Gandhi National
Park.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

----

29/07/15

20/08/15

Weight
(Kg)
7.325
7.200
--

Failure Load
(kN)
560
460
--

Compressive
Strength (MPa)
24.89
20.44
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15729

Date: 21/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/404 dated 20/08/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F3 level roof slab concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

: 150 mm x 150 mm x 150 mm


Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
740
710
725

Compressive
Strength (MPa)

1
J4
8.325
2
J5
23/07/15
20/08/15
8.445
3
J6
8.165
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

32.89
31.55
32.22

Testing officer

CRC No: 15730

Date: 21/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/405 dated 20/08/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F3 level roof slab concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Failure
Load
(kN)
720
730
700

Weight
(Kg)

Compressive
Strength (MPa)

1
K4
8.285
2
K5
23/07/15
20/08/15
8.190
3
K6
8.430
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

32.00
32.44
31.11

Testing officer

CRC No: 15741

Date: 24/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Karunanidhe Constructions (P) Ltd, Coimbatore.

Ref No

: Letter dated 21/08/15.

Project*

: Astrum Grand View, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

14/08/15

21/08/15

Weight
(Kg)
8.250
8.270
8.160

Failure Load
(kN)
480
465
470

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
21.33
20.67
20.89

Testing officer

CRC No: 15747

Date: 24/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Amarnath, # D.7, Paramahamsa Road, Yadavagiri,


Mysore.

Ref No

: Letter dated 24/08/15.

Project*

: Residence Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

11/08/15

24/08/15

Weight
(Kg)
8.255
8.230
8.285

Failure Load
(kN)
540
580
525

Compressive
Strength (MPa)
24.00
25.78
23.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15657

Date: 03/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, JNNURM, MCC, Mysore.

Ref No

: Letter No. MCC/JNNURM/AEE-4//2011-12 dated 31/07/15.

Project*

: Multi level parking Raft concrete in Town hall premises.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/07/15

31/07/15

8.060
7.880
8.085

Failure
Load
(kN)
255
300
315

Compressive
Strength (MPa)
11.33
13.33
14.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14753

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Vyshak, Bamboo Bazaar, Mysore.

Ref No

: Letter dated 24/08/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
395
200
350

1
-7.940
14/08/15
25/08/15
2
-7.865
3
-7.795
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
17.55
8.89
15.55

Testing officer

CRC No: 15754

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Damden Properties, Hebbal industrial Area, Mysore.

Ref No

: Letter dated 25/08/15.

Project*

: Damden Solarium, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, 7th Floor Roof Block 5.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/07/15

25/08/15

7.985
8.040
7.885

Failure
Load
(kN)
550
545
500

Compressive
Strength (MPa)
24.44
24.22
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15758

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Layout at Saptha 5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/08/15

24/08/15

8.235
7.785
8.060

Failure
Load
(kN)
850
600
350

Compressive
Strength (MPa)
37.78
26.67
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15758

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Layout at Saptha 5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

14/08/15

24/08/15

8.295
8.065
8.125

Failure
Load
(kN)
320
690
330

Compressive
Strength (MPa)
14.22
30.67
14.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15755

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF top slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

09/08/15

25/08/15

7.800
7.895
8.090

Failure
Load
(kN)
380
490
300

Compressive
Strength (MPa)
16.89
31.78
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15755

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Columns.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

29/07/15

25/08/15

7.830
7.780
7.665

Failure
Load
(kN)
400
485
320

Compressive
Strength (MPa)
17.78
21.55
14.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15755

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, CWR top slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/08/15

Date of
Testing

Weight
(Kg)

25/08/15

7.900
7.895
7.950

Failure
Load
(kN)
260
335
380

Compressive
Strength (MPa)
11.55
14.89
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15755

Date: 26/08/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pump house plinth beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

29/07/15

25/08/15

7.790
7.860
7.845

Failure
Load
(kN)
370
435
490

Compressive
Strength (MPa)
16.44
19.33
21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15755

Date: 26/08/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pump House Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
26/07/15

Date of
Testing

Weight
(Kg)

25/08/15

7.855
7.795
8.960

Failure
Load
(kN)
340
370
370

Compressive
Strength (MPa)
15.11
16.44
16.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15755

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Staff Quarters roof slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/08/15

Date of
Testing

Weight
(Kg)

25/08/15

8.035
7.925
8.060

Failure
Load
(kN)
220
240
340

Compressive
Strength (MPa)
9.78
10.67
15.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15755

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR.01 columns above brace beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/08/15

Date of
Testing

Weight
(Kg)

25/08/15

7.935
8.065
8.000

Failure
Load
(kN)
550
400
490

Compressive
Strength (MPa)
24.44
17.78
21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15755

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 25/08/15.

Project*

: Cauvery drinking water facilities toMavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR.01 Brace beam

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/07/15

25/08/15

7.775
7.790
8.020

Failure
Load
(kN)
250
340
330

Compressive
Strength (MPa)
11.11
15.11
14.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15721

Date: 20/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysuru Division, Mysuru.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 18/08/15.

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Ground Floor column concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
660
610
610

1
-8.180
20/07/15
18/08/15
2
-8.120
3
-8.150
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
29.33
27.11
27.11

Testing officer

CRC No: 15759

Date: 26/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, JNNURM, MCC, Mysore.

Ref No

: Letter No. MCC/JNNURM/AEE-4//2011-12 dated 13/08/15.

Project*

: Multi level parking @ Town hall.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing F-5, F-6 & F-9. (Grid No. 17, 18, 19)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
06/08/15

Date of
Testing

Weight
(Kg)

25/08/15

7.700
7.785
7.770

Failure
Load
(kN)
400
340
350

Compressive
Strength (MPa)
17.78
15.11
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15760

Date: 27/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SNR Associates, Mysore.

Ref No

: Letter dated 26/08/15.

Project*

: Construction of Museum at Suttur,

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Column Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

17/08/15

26/08/15

7.900
7.800
7.695

Failure
Load
(kN)
440
470
400

Compressive
Strength (MPa)
19.55
20.89
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15764

Date: 27/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MSR Concrete, Koorgalli Industrial Area, Mysore.

Ref No

: Letter dated 26/08/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
18/08/15

Date of
Testing

Weight
(Kg)

26/08/15

8.150
8.125
8.025

Failure
Load
(kN)
770
550
470

Compressive
Strength (MPa)
34.22
24.44
20.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15763

Date: 27/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Simplex Infrastructure Limited, KRS Road,


Hulikere Village, Srirangapatna Taluk.

Ref No

: Letter dated 26/08/15.

Project*

: Zuari Garden City.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, SIL/ZGC/FB1 Slab/001

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

17/08/15

26/08/15

7.975
8.075
8.265

Failure
Load
(kN)
570
600
575

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
25.33
26.67
25.55

3. Any correction invalidates this report.


Testing officer

CRC No: 15763

Date: 27/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Simplex Infrastructure Limited, KRS Road,


Hulikere Village, Srirangapatna Taluk.

Ref No

: Letter dated 26/08/15.

Project*

: Zuari Garden City.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, SIL/ZGC/FB1 Slab/001

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/08/15

Date of
Testing

Weight
(Kg)

26/08/15

8.335
8.215
8.270

Failure
Load
(kN)
675
710
750

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
30.00
31.55
33.33

Testing officer

CRC No: 15773

Date: 28/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 27/08/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Column

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
29/07/15

Date of
Testing

Weight
(Kg)

27/08/15

7.635
7.830
7.615

Failure
Load
(kN)
600
625
560

Compressive
Strength (MPa)
26.67
27.78
24.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15773

Date: 28/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 27/08/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/07/15

Date of
Testing

Weight
(Kg)

27/08/15

7.850
7.675
7.810

Failure
Load
(kN)
690
600
760

Compressive
Strength (MPa)
30.67
26.67
33.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15775

Date: 29/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: --

Project*

: Construction of building and other related works for


establishment & Mega dairy @ Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
22/08/15

Date of
Testing

Weight
(Kg)

29/08/15

8.290
8.060
8.240

Failure
Load
(kN)
420
415
400

Compressive
Strength (MPa)
18.67
18.44
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15768

Date: 28/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri Bindumadhava Religious Trust, Belaguru, Hosadurga Tq.

Ref No

: Letter dated 27/08/15.

Project*

: Sabha Bhavana, Belaguru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6
7

--------

Date of
Casting

29/07/15

Date of
Testing

Weight
(Kg)

27/08/15

7.925
7.650
7.325
7.705
7.370
7.485
7.645

Failure
Load
(kN)
500
200
300
275
270
205
230

Compressive
Strength (MPa)
22.22
8.89
13.33
12.72
12.00
9.11
10.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15778

Date: 29/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 28/08/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. (RMC)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/08/15

Date of
Testing

Weight
(Kg)

28/08/15

7.980
8.015
8.095

Failure
Load
(kN)
370
300
375

Compressive
Strength (MPa)
16.44
13.33
16.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15779

Date: 29/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 28/08/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/07/15

28/08/15

8.175
8.200
8.100

Failure
Load
(kN)
700
845
700

Compressive
Strength (MPa)
31.11
37.55
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15779

Date: 29/08/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 28/08/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
31/07/15

Date of
Testing

Weight
(Kg)

28/08/15

8.025
8.290
7.850

Failure
Load
(kN)
370
590
300

Compressive
Strength (MPa)
16.44
26.22
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15779

Date: 29/08/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 28/08/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/08/15

Date of
Testing

Weight
(Kg)

28/08/15

7.845
7.775
7.870

Failure
Load
(kN)
390
250
350

Compressive
Strength (MPa)
17.33
11.11
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15786

Date: 01/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: G. Shashidhar, D. Block, JP Nagar, Mysore.

Ref No

: Letter dated 31/08/15

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. Cellar Roof Slab

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/08/15

Date of
Testing

Weight
(Kg)

31/08/15

7.720
7.680
7.670

Failure
Load
(kN)
290
255
290

Compressive
Strength (MPa)
12.89
11.33
12.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15783

Date: 01/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 31/08/15..

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab 2nd Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/08/15

Date of
Testing

Weight
(Kg)

31/08/15

7.995
8.005
8.000

Failure
Load
(kN)
400
400
400

Compressive
Strength (MPa)
17.78
17.78
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15782

Date: 01/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, NH Sub division, Malavalli.

Ref No

: Letter dated 28/06/15.

Project*

: Work of rehabilitation of Shivanasamudra bridge at


Chainage 357.00 km of NH-209. D-Section.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
26/03/15

Date of
Testing

Weight
(Kg)

31/08/15

7.555
7.600
7.585

Failure
Load
(kN)
920
830
830

Compressive
Strength (MPa)
40.89
36.89
36.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15782

Date: 01/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, NH Sub division, Malavalli.

Ref No

: Letter dated 28/06/15.

Project*

: Work of rehabilitation of Shivanasamudra bridge at


Chainage 357.00 km of NH-209. D-Section.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/03/15

31/08/15

7.615
7.475
7.500

Failure
Load
(kN)
930
950
880

Compressive
Strength (MPa)
41.33
42.22
39.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15782

Date: 01/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, NH Sub division, Malavalli.

Ref No

: Letter dated 28/06/15.

Project*

: Work of rehabilitation of Shivanasamudra bridge at


Chainage 357.00 km of NH-209. D-Section.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/04/15

Date of
Testing

Weight
(Kg)

31/08/15

7.640
7.495
7.785

Failure
Load
(kN)
830
850
810

Compressive
Strength (MPa)
36.89
37.78
36.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15782

Date: 01/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, NH Sub division, Malavalli.

Ref No

: Letter dated 28/06/15.

Project*

: Work of rehabilitation of Shivanasamudra bridge at


Chainage 357.00 km of NH-209. D-Section.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
10/04/15

Date of
Testing

Weight
(Kg)

31/08/15

7.710
7.700
7.700

Failure
Load
(kN)
800
835
820

Compressive
Strength (MPa)
35.55
37.11
36.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15782

Date: 01/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, NH Sub division, Malavalli.

Ref No

: Letter dated 28/06/15.

Project*

: Work of rehabilitation of Shivanasamudra bridge at


Chainage 357.00 km of NH-209. D-Section.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/05/15

31/08/15

7.595
7.670
7.600

Failure
Load
(kN)
910
900
890

Compressive
Strength (MPa)
40.44
40.00
39.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15782

Date: 01/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, NH Sub division, Malavalli.

Ref No

: Letter dated 28/06/15.

Project*

: Work of rehabilitation of Shivanasamudra bridge at


Chainage 357.00 km of NH-209. D-Section.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

09/04/15

31/08/15

7.910
7.930
7.980

Failure
Load
(kN)
910
800
810

Compressive
Strength (MPa)
40.44
35.55
36.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15800

Date: 04/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Balaji Constructions, Nazarbad, Mysore.

Ref No

: Letter dated 03/09/15.

Project*

: Sri. Balaji Constructions (Residential Apartment)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/08/15

03/09/15

7.890
7.850
7.895

Failure
Load
(kN)
300
270
300

Compressive
Strength (MPa)
13.33
12.00
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15791

Date: 03/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 01/09/15.

Project*

: Layout at Saptha phase 5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

17/08/15

27/08/15

7.980
7.980
8.085

Failure
Load
(kN)
650
665
710

Compressive
Strength (MPa)
28.89
29.55
31.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15791

Date: 03/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 01/09/15.

Project*

: Layout at Saptha phase 5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/08/15

Date of
Testing

Weight
(Kg)

01/09/15

8.000
7.960
8.070

Failure
Load
(kN)
300
300
270

Compressive
Strength (MPa)
13.33
13.33
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15803

Date: 05/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 04/09/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Column Face one 2nd floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/08/15

04/09/15

7.935
7.835
8.040

Failure
Load
(kN)
400
435
380

Compressive
Strength (MPa)
17.78
19.33
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15803

Date: 05/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 04/09/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Stair case Face two Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/08/15

Date of
Testing

Weight
(Kg)

04/09/15

7.930
7.920
7.880

Failure
Load
(kN)
380
390
390

Compressive
Strength (MPa)
16.89
17.33
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15806

Date: 07/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: N. Ranga Rao & Sons Pvt Ltd, Mysore.

Ref No

: Letter dated 04/08/15.

Project*

: Chamarajanagar Project.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

27/08/15

05/09/15

7.367
7.930
8.125

Failure
Load
(kN)
250
330
325

Compressive
Strength (MPa)
11.11
14.67
14.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15806

Date: 07/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: N. Ranga Rao & Sons Pvt Ltd, Mysore.

Ref No

: Letter dated 05/08/15.

Project*

: Chamarajanagar Project.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/08/15

05/09/15

8.240
8.110
8.070

Failure
Load
(kN)
310
310
290

Compressive
Strength (MPa)
13.78
13.78
12.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15817

Date: 08/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 07/09/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Ground Floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

10/08/15

07/09/15

7.920
8.085
7.960

520
700
740

23.11
31.11
32.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15810

Date: 08/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: G. Shashidhar, D. Block, JP Nagar, Mysore.

Ref No

: Letter dated 07/09/15.

Project*

: Construction of Mini Party Hall @ JPNagar C Block, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. RCC Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

27/08/15

07/09/15

7.810

Failure
Load
(kN)
380

Compressive
Strength (MPa)
16.89

2
3

---

7.580
--

450
--

20.00
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15809

Date: 08/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysuru Division, Mysore.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 07/09/15.

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column concrete (First Floor).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

29/08/15

07/09/15

8.135

Failure
Load
(kN)
430

Compressive
Strength (MPa)
19.11

2
-8.240
410
3
-8.240
430
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

18.22
19.11

Testing officer

CRC No: 15814

Date: 08/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Arihant Infrastructure, 3rd stage, Industrial Suburb,


Rajarajeshwari Temple Road, Vishweshwara Nagar, Mysore.

Ref No

: Letter dated 07/09/15.

Project*

: Construciton of Appartment in Vishweshwar Nagar, Mysore/

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

--

07/09/15

8.050
8.015
8.032

Failure
Load
(kN)
300
300
320

Compressive
Strength (MPa)
13.33
13.33
14.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15821

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 08/09/15.

Project*

: Layout at Saptha 5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
31/08/15

Date of
Testing

Weight
(Kg)

08/09/15

8.120
8.235
8.010

Failure
Load
(kN)
630
585
570

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
28.00
26.00
25.33

Testing officer

CRC No: 15821

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 08/09/15.

Project*

: Layout at Saptha 5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/09/15

Date of
Testing

Weight
(Kg)

08/09/15

8.070
8.245
8.330

Failure
Load
(kN)
530
460
500

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
23.55
20.44
22.22

Testing officer

CRC No: 15828

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, JNNURM, MCC, Mysore.

Ref No

: Letter dated 09/09/15.

Project*

: Mysore Townhall-Parking.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
31/08/15

Date of
Testing

Weight
(Kg)

09/09/15

7.790
7.715
7.795

Failure
Load
(kN)
550
600
750

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
24.44
26.67
33.33

Testing officer

CRC No: 15824

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 09/09/15.

Project*

: Construction of building and other related works for


establishment & Mega dairy @ Alanahalli, Mysore for
Mysore Milk Union.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/09/15

Date of
Testing

Weight
(Kg)

09/09/15

8.010
7.895
7.855

Failure
Load
(kN)
360
330
350

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.00
14.67
15.55

Testing officer

CRC No: 15824

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 09/09/15.

Project*

: Construction of building and other related works for


establishment & Mega dairy @ Alanahalli, Mysore for
Mysore Milk Union.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/09/15

09/09/15

8.075
8.160
8.015

Failure
Load
(kN)
545
560
525

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
24.22
24.89
23.33

Testing officer

CRC No: 15820

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer, Permanent Way, SWR, KR Nagar.

Ref No

: Letter No. SSE/P.Way/KRNR dated 08/08/2015.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

08/08/15

Date of
Testing

08/09/15

7.960

Failure
Load
(kN)
695

8.080

700

31.11

8.250

700

31.11

Weight
(Kg)

Compressive
Strength (MPa)
30.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15820

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer, Permanent Way, SWR, KR Nagar.

Ref No

: Letter No. SSE/P.Way/KRNR dated 08/08/2015.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

06/08/15

Date of
Testing

08/09/15

7.730

Failure
Load
(kN)
710

7.955

750

33.33

7.955

715

31.78

Weight
(Kg)

Compressive
Strength (MPa)
31.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15820

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer, Permanent Way, SWR, KR Nagar.

Ref No

: Letter No. SSE/P.Way/KRNR dated 08/08/2015.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

07/08/15

Date of
Testing

08/09/15

8.035

Failure
Load
(kN)
755

8.025

760

33.78

7.855

760

33.78

Weight
(Kg)

Compressive
Strength (MPa)
33.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15820

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer, Permanent Way, SWR, KR Nagar.

Ref No

: Letter No. SSE/P.Way/KRNR dated 09/08/2015.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

10/08/15

Date of
Testing

08/09/15

8.005

Failure
Load
(kN)
690

7.735

710

31.55

8.020

690

30.67

Weight
(Kg)

Compressive
Strength (MPa)
30.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15820

Date: 10/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer, Permanent Way, SWR, KR Nagar.

Ref No

: Letter No. SSE/P.Way/KRNR dated 09/08/2015.

Project*

: Mysore-Arsikere section-Elimination of manned level crossing


No. 20 at km 24/200-300 and 70 at km 79/400-500 by
constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

--

--

--

Date of
Casting

12/08/15

Date of
Testing

08/09/15

7.870

Failure
Load
(kN)
700

8.025

700

31.11

7.925

720

32.00

Weight
(Kg)

Compressive
Strength (MPa)
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15832

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 10/09/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab F2 1st Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
03/09/15

Date of
Testing

Weight
(Kg)

10/09/15

7.875
7.890
8.020

Failure
Load
(kN)
365
385
440

Compressive
Strength (MPa)
16.22
17.11
19.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15832

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 10/09/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Stair Third Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

31/08/15

10/09/15

7.845
7.880
7.900

Failure
Load
(kN)
400
500
460

Compressive
Strength (MPa)
17.78
22.22
20.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15832

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 10/09/15.

Project*

: Construction of SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Column F2 First floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

13/08/15

10/09/15

8.020
7.885
7.950

Failure
Load
(kN)
665
610
510

Compressive
Strength (MPa)
29.55
27.11
22.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15790

Date: 02/09/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/439 dated 01/09/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F4 level roof slab concrete 31.70 cum.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
500
510
505

1
N1
8.215
2
N2
25/08/15
01/09/15
8.185
3
N3
8.235
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.22
22.67
22.44

Testing officer

CRC No: 15790

Date: 02/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/438 dated 01/09/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F4 level roof slab concrete 31.70 cum.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
495
500
505

1
M1
8.230
2
M2
25/08/15
01/09/15
8.260
3
M3
8.265
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.00
22.22
22.44

Testing officer

CRC No: 15835

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 11/09/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 other


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF First floor top slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/09/15

11/09/15

7.965
7.920
7.805

Failure
Load
(kN)
280
310
280

Compressive
Strength (MPa)
12.44
13.78
12.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15835

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 11/09/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 other

villages of K.R. Nagar Taluk, Mysore district.


Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pump House Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/09/15

Date of
Testing

Weight
(Kg)

11/09/15

8.205
8.180
8.255

Failure
Load
(kN)
285
250
290

Compressive
Strength (MPa)
12.67
11.11
12.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15835

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 11/09/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 other


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Top Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/08/15

Date of
Testing

Weight
(Kg)

11/09/15

7.705
7.915
7.775

Failure
Load
(kN)
680
440
385

Compressive
Strength (MPa)
30.22
19.55
17.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15838

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M.S. Constructions, Mysore.

Ref No

: Letter dated 11/09/15

Project*

: Construction of Ideal Jawa Rotary School, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Roof.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
350
345
350

1
-8.285
04/09/15
11/09/15
2
-8.295
3
-8.280
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
15.55
15.33
15.55

Testing officer

CRC No: 15841

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 11/09/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3

----

: 150 mm x 150 mm x 150 mm


Date of
Casting
31/08/15

Date of
Testing

Weight
(Kg)

11/09/15

8.060
8.210
8.225

Failure
Load
(kN)
450
565
400

Compressive
Strength (MPa)
20.00
25.11
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15841

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 11/09/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/09/15

11/09/15

7.835
8.120
8.005

Failure
Load
(kN)
400
470
420

Compressive
Strength (MPa)
17.78
20.89
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15841

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 11/09/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

11/08/15

11/09/15

7.875
8.015
8.050

450
655
555

20.00
29.11
24.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15841

Date: 12/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 11/09/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

24/08/15

11/09/15

8.295
8.150

Failure
Load
(kN)
420
730

Compressive
Strength (MPa)
18.67
32.44

--

8.365

600

26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15847

Date: 14/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysuru division, Mysuru.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bengaluru.

Ref No

: Letter dated 11/09/15.

Project*

: Construction of New RTO Office, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, G. Floor Slab Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
14/08/15

Date of
Testing

Weight
(Kg)

12/09/15

8.130
8.045
8.065

Failure
Load
(kN)
660
690
660

Compressive
Strength (MPa)
29.33
30.67
29.33

Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15848

Date: 14/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 12/09/15.

Project*

: Construction of building and other related works for


establishment & Mega dairy @ Alanahalli, Mysore for
Mysore Milk Union.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
22/08/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

12/09/15

8.130
8.010
8.135

Failure
Load
(kN)
580
700
590

Compressive
Strength (MPa)
25.78
31.11
26.22

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15845

Date: 14/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Amrithavakhini Designers & Engineers, Kollegala.

Ref No

: Letter dated 12/09/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

14
15
16

Date of
Casting
03/09/15

Date of
Testing

Weight
(Kg)

12/09/15

7.985
7.665
7.860

Failure
Load
(kN)
480
440
400

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
21.33
19.55
17.78

Testing officer

CRC No: 15845

Date: 14/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Amrithavakhini Designers & Engineers, Kollegala.

Ref No

: Letter dated 12/09/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

19
20
21

Date of
Casting
03/09/15

Date of
Testing

Weight
(Kg)

12/09/15

7.450
7.650
7.966

Failure
Load
(kN)
440
490
425

Compressive
Strength (MPa)
19.55
21.78
18.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15845

Date: 14/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Amrithavakhini Designers & Engineers, Kollegala.

Ref No

: Letter dated 12/09/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

31
32
33

Date of
Casting
05/09/15

Date of
Testing

Weight
(Kg)

12/09/15

7.800
7.935
8.168

Failure
Load
(kN)
440
420
660

Compressive
Strength (MPa)
19.55
18.67
29.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15852

Date: 15/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 14/09/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 other


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 01 Bottom Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/09/15

14/09/15

8.060
8.205
8.020

Failure
Load
(kN)
330
380
250

Compressive
Strength (MPa)
14.67
16.89
11.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15857

Date: 18/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: STG Concrete Products, Myore.

Ref No

: --

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/09/15

15/09/15

8.135
8.060
8.135

Failure
Load
(kN)
350
365
350

Compressive
Strength (MPa)
15.55
16.22
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15857

Date: 18/09/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: STG Concrete Products, Myore.

Ref No

: --

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
08/09/15

Date of
Testing

Weight
(Kg)

15/09/15

7.990
8.100
8.090

Failure
Load
(kN)
360
340
360

Compressive
Strength (MPa)
16.00
15.11
16.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15857

Date: 18/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: STG Concrete Products, Myore.

Ref No

: --

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M45.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

19/08/15

15/09/15

8.090
8.295
8.255

Failure
Load
(kN)
1300
1000
1280

Compressive
Strength (MPa)
57.78
44.44
56.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15857

Date: 18/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: STG Concrete Products, Myore.

Ref No

: --

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M45.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/09/15

15/09/15

8.275
8.185
8.420

Failure
Load
(kN)
810
945
900

Compressive
Strength (MPa)
36.00
42.00
40.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15864

Date: 18/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Simplex Infrastructure Limited, KRS Road,


Hulikere Village, Srirangapatna Taluk.

Ref No

: Letter dated 14/09/15.

Project*

: Zuari Garden City.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, SIL/ZGC/FB1 Slab/001

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/08/15

Date of
Testing

Weight
(Kg)

15/09/15

8.070
8.155
8.210

Failure
Load
(kN)
625
650
650

Compressive
Strength (MPa)
27.78
28.89
28.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15864

Date: 18/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Simplex Infrastructure Limited, KRS Road,


Hulikere Village, Srirangapatna Taluk.

Ref No

: Letter dated 14/09/15.

Project*

: Zuari Garden City.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, SIL/ZGC/FB1 Slab/001

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

17/08/15

15/09/15

8.275
8.225
8.215

Failure
Load
(kN)
890
810
880

Compressive
Strength (MPa)
39.55
36.00
39.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15868

Date: 21/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: The Executive Engineer, Mysore Division, KSPHC Ltd,


Mysore.

Contractor Name

: BM Nataraju, Shankarapuram, Bangalore.

Ref No

: Letter dated 14909/15.

Project*

: Construction of Guest House for SI Level Officers @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6
7
8
9

----------

Date of
Casting

12/09/15

Date of
Testing

Weight
(Kg)

19/09/15

8.125
8.225
8.155
8.210
8.130
8.115
8.110
8.170
8.190

Failure
Load
(kN)
380
360
365
400
425
450
415
370
420

Compressive
Strength (MPa)
16.89
16.00
16.22
17.78
18.89
20.00
18.44
16.44
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 14748

Date: 21/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer (works), South Western Railway,


Mysore.

Ref No

: Letter No. 390/SW/MYS/15 dated 07/09/15.

Project*

: Improvements to watering arrangements at Mysore City.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: RCC work for main shaft wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

30/08/15

19/09/15

7.765
7.410
7.595

Failure
Load
(kN)
385
440
430

Compressive
Strength (MPa)
17.11
19.55
19.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14748

Date: 21/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer (works), South Western Railway,


Mysore.

Ref No

: Letter No. 390/SW/MYS/15 dated 10/09/15.

Project*

: Improvements to watering arrangements at Mysore City.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: RCC work for main shaft wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
03/09/15

Date of
Testing

Weight
(Kg)

19/09/15

7.820
7.800
7.790

Failure
Load
(kN)
580
585
565

Compressive
Strength (MPa)
25.78
26.00
25.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 14748

Date: 21/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer (works), South Western Railway,


Mysore.

Ref No

: Letter No. 390/SW/MYS/15 dated 15/09/15.

Project*

: Improvements to watering arrangements at Mysore City.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: RCC work for main shaft wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/09/15

Date of
Testing

Weight
(Kg)

19/09/15

8.075
7.970
7.620

Failure
Load
(kN)
720
750
700

Compressive
Strength (MPa)
32.00
33.33
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15876

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysore Division, Mysore.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 22/09/15.

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, First Floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
475
460
490

1
-8.055
15/09/15
22/09/15
2
-8.060
3
-8.170
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
21.11
20.44
21.78

Testing officer

CRC No: 15872

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 22/09/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 3rd Floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

15/09/15

22/09/15

8.095
8.130
7.925

Failure
Load
(kN)
350
345
300

Compressive
Strength (MPa)
15.55
15.33
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15872

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 22/09/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, 2nd Floor Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/09/15

22/09/15

7.780
7.815
7.755

Failure
Load
(kN)
355
370
380

Compressive
Strength (MPa)
15.78
16.44
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15872

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 22/09/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 2nd Floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

24/08/15

22/09/15

8.060
8.000
8.165

650
665
560

28.89
29.55
24.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15874

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MSR Concrete, Koorgalli Industrial Area, Mysore.

Ref No

: Letter dated 22/09/15

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40 (70/30)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

08/09/15

22/09/15

7.940
8.110

Failure
Load
(kN)
725
520

Compressive
Strength (MPa)
32.22
23.11

--

8.165

715

31.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15874

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MSR Concrete, Koorgalli Industrial Area, Mysore.

Ref No

: Letter dated 22/09/15

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20 (60/40)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
11/09/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

22/09/15

8.215
8.120
8.190

Failure
Load
(kN)
540
630
490

Compressive
Strength (MPa)
24.00
28.00
21.78

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15874

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MSR Concrete, Koorgalli Industrial Area, Mysore.

Ref No

: Letter dated 22/09/15

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35 (60/40)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/09/15

Date of
Testing

Weight
(Kg)

22/09/15

8.120
8.145
8.140

Failure
Load
(kN)
710
715
750

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
31.55
31.78
33.33

Testing officer

CRC No: 15874

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MSR Concrete, Koorgalli Industrial Area, Mysore.

Ref No

: Letter dated 22/09/15

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M40 (70/30)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

18/08/15

22/09/15

8.180
8.100
8.065

Failure
Load
(kN)
750
1195
780

Compressive
Strength (MPa)
33.33
53.11
34.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15874

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MSR Concrete, Koorgalli Industrial Area, Mysore.

Ref No

: Letter dated 22/09/15

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20 (50/50)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

11/09/15

22/09/15

8.110
8.090
8.160

Failure
Load
(kN)
540
450
595

Compressive
Strength (MPa)
24.00
20.00
26.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15881

Date: 26/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SNR Associates, Krishnamurthy Puram, Mysore.

Ref No

: Letter dated 23/09/15.

Project*

: Construction of Museum at Suttur,

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, (Site mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3
Note:

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

25/08/15

23/09/15

8.025
7.980
7.930

Failure
Load
(kN)
550
615
640

Compressive
Strength (MPa)
24.44
27.33
28.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15880

Date: 26/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri Bindumadhava Religious Trust, Belaguru, Hosadurga Tq,


Chitradurga Dist.

Ref No

: Letter dated 23/09/15.

Project*

: Theerti Sabha Bhavana, Belaguru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
375
360
350
285
280
350

1
-7.735
2
-7.985
3
-8.020
14/09/15
23/09/15
4
-7.855
5
-7.840
6
-8.100
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.67
16.00
15.55
12.67
12.44
15.55

Testing officer

CRC No: 15883

Date: 26/09/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 23/09/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/08/15

23/09/15

7.750
7.790
7.785

Failure
Load
(kN)
450
575
530

Compressive
Strength (MPa)
20.00
25.55
23.55

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15883

Date: 26/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 23/09/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

15/09/15

23/09/15

8.080
8.035
8.010

Failure
Load
(kN)
360
320
250

Compressive
Strength (MPa)
16.00
14.22
11.11

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15883

Date: 26/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 23/09/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/09/15

23/09/15

7.925
8.035
8.235

Failure
Load
(kN)
395
200
350

Compressive
Strength (MPa)
17.55
8.89
15.55

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15883

Date: 26/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 23/09/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/08/15

23/09/15

8.275
8.230
8.255

Failure
Load
(kN)
700
610
690

Compressive
Strength (MPa)
31.11
27.11
30.67

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15883

Date: 26/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 23/09/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

11/09/15

23/09/15

8.195
8.000
8.035

Failure
Load
(kN)
510
630
655

Compressive
Strength (MPa)
22.67
28.00
29.11

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15883

Date: 26/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 23/09/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/08/15

23/09/15

8.285
8.430
8.225

Failure
Load
(kN)
550
510
710

Compressive
Strength (MPa)
24.44
22.67
31.55

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15883

Date: 26/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 23/09/15

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

09/09/15

23/09/15

8.210
7.925
7.975

Failure
Load
(kN)
440
250
200

Compressive
Strength (MPa)
19.55
11.11
8.89

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15890

Date: 29/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hi rise Infratech Pvt Ltd, Assam.

Ref No

: Letter dated 28/09/15

Project*

: Construction of Science Museum at Kukkarahalli Lake,


Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/09/15

28/09/15

8.225
8.240
8.095

Failure
Load
(kN)
340
330
320

Compressive
Strength (MPa)
15.11
14.67
14.22

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15889

Date: 29/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 29/09/15.

Project*

: Sub Way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

21/09/15

29/09/15

8.260
8.265
8.260

950
830
980

42.22
36.89
43.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15888

Date: 29/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: A.V. Constructions, Vijayanagar, Mysore.

Ref No

: Letter dated 26/09/15.

Project*

: Construction of Neuro Care Centre at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RMC(Lafarge)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

19/09/15

28/09/15

8.235
8.240
8.275

440
445
450

19.55
19.78
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15886

Date: 28/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB Mysuru Division, Mysuru.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 26/09/15.

Project*

: Construction of New RTO office at Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, First Floor Column Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
620
610
610

Compressive
Strength (MPa)

1
-8.020
29/08/15
26/09/15
2
-8.100
3
-8.435
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

27.55
27.11
27.11

Testing officer

CRC No: 15896

Date: 29/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: G. Shashidhar, D. Block, JP Nagar, Mysore.

Ref No

: Letter dated 28/09/15.

Project*

: Construction of Mini Party Hall @ D Block,


JP Nagar, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. Roof Slab Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

24/08/15

28/09/15

7.715
7.685
7.860

Failure
Load
(kN)
450
475
350

Compressive
Strength (MPa)
20.00
21.11
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15900

Date: 30/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 29/09/15

Project*

: Construction of building and other related works for


establishment & Mega dairy @ Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

01/09/15

29/09/15

8.065
7.945
8.040

Failure
Load
(kN)
510
680
560

Compressive
Strength (MPa)
22.67
30.22
24.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15900

Date: 30/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 29/09/15

Project*

: Construction of building and other related works for


establishment & Mega dairy @ Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

01/09/15

29/09/15

7.980
8.010
8.260

Failure
Load
(kN)
500
515
550

Compressive
Strength (MPa)
22.22
22.89
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15897

Date: 30/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Amrithavakhini Designers & Engineers, Kollegala.

Ref No

: Letter dated 29/09/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, (design mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3
4

SH1
SH2
SH4
SH5

10/09/15

29/09/15

7.660
7.835
7.830
7.590

250
395
310
340

11.11
17.55
13.78
15.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15897

Date: 30/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Amrithavakhini Designers & Engineers, Kollegala.

Ref No

: Letter dated 29/09/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressiv
e Strength
(MPa)

Remarks

10

2
3
4
5
7
8

17
18
22
23
35
36

02/09/15

29/09/15

03/09/15

29/09/15

05/09/15

29/09/15

8.230

630

28.00

8.050
8.000
7.630
7.780
8.170
8.130

640
480
470
600
810
980

28.44
21.33
20.89
26.67
36.00
43.55

M25 Design
mix
M20 Nominal
mix
M25
MS+30% RS

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15935

Date: 06/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SNR Associates, Krishnamurthy Puram, Mysore.

Ref No

: Letter dated 05/10/15.

Project*

: Construction of Museum at Suttur,

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, (Site Mix) Plinth beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

21/09/15

05/10/15

8.090

Failure
Load
(kN)
400

Compressive
Strength (MPa)
17.78

2
3

---

7.905
--

550
--

24.44
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15929

Date: 05/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 03/10/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
14/09/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

03/10/15

8.085
8.425
8.620

Failure
Load
(kN)
550
810
700

Compressive
Strength (MPa)
24.44
36.00
31.11

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15927

Date: 05/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MS Constructions, Mysore.

Ref No

: Letter dated 03/10/15.

Project*

: Ideal Jawa Rotary School.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Roof casting.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/09/15

Date of
Testing

Weight
(Kg)

03/10/15

8.180
8.255
8.200

Failure
Load
(kN)
630
640
680

Compressive
Strength (MPa)
28.00
28.44
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15927

Date: 05/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MS Constructions, Mysore.

Ref No

: Letter dated 03/10/15.

Project*

: Ideal Jawa Rotary School.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
26/09/15

Date of
Testing

Weight
(Kg)

03/10/15

7.850
7.470
7.515

Failure
Load
(kN)
475
480
520

Compressive
Strength (MPa)
21.11
21.33
23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15926

Date: 05/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Royal Concorde International School, Bogadi, Mysore.

Ref No

: Letter dated 03/10/15.

Project*

: Construction of Royale Concorde International School.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, (STG).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

24/09/15

03/10/15

Weight
(Kg)
8.000
8.100
8.230

Failure Load
(kN)
620
675
665

Compressive
Strength (MPa)
27.55
30.00
29.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15924

Date: 03/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 01/10/15.

Project*

: Sub Way of Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
22/09/15

Date of
Testing

Weight
(Kg)

01/10/15

8.035
8.100
8.210

Failure
Load
(kN)
650
690
675

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
28.89
30.67
30.00

Testing officer

CRC No: 15942

Date: 08/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&DB Board Division, Mysuru.

Ref No

: --

Project*

: Construction of Sump, pump house, chain link fencing and


allied works for IBPS-2, Supply and fixing of bulk flow meter
to feeder mains under Augmentation of water supply to
Mysuru city from Kabini River under Jn-NURM.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Sump slab concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

29/09/15

06/10/15

8.370
8.320
8.315

Failure
Load
(kN)
500
525
500

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
22.22
23.33
22.22

3. Any correction invalidates this report.

Testing officer

CRC No: 15941

Date: 08/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hi Rise Infratech Pvt Ltd, Jorhat, Assam.

Ref No

: Letter dated 05/10/15

Project*

: Construction of Science Museum at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/09/15

06/10/15

8.080
8.165
8.090

Failure
Load
(kN)
270
355
350

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
12.00
15.78
15.55

Testing officer

CRC No: 15946

Date: 08/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 07/10/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab P2 First Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
03/09/15

Date of
Testing

Weight
(Kg)

07/10/15

8.140
8.000
7.915

Failure
Load
(kN)
650
600
665

Compressive
Strength (MPa)
28.89
26.67
29.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15946

Date: 08/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 07/10/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, P1 3rd Floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/09/15

Date of
Testing

Weight
(Kg)

07/10/15

8.050
7.965
8.090

Failure
Load
(kN)
450
500
590

Compressive
Strength (MPa)
20.00
22.22
26.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15946

Date: 08/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 07/10/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, P2 2nd Floor Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
29/09/15

Date of
Testing

Weight
(Kg)

07/10/15

8.285
8.175
8.125

Failure
Load
(kN)
440
400
320

Compressive
Strength (MPa)
16.55
17.78
14.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Mavathur and other


31 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR-2 Column below GL.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

12/09/15

05/10/15

7.675
7.780
7.830

Failure
Load
(kN)
315
320
400

Compressive
Strength (MPa)
14.00
14.22
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Malanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Aerator Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
08/09/15

Date of
Testing

Weight
(Kg)

05/10/15

8.280
8.185
8.145

Failure
Load
(kN)
405
350
355

Compressive
Strength (MPa)
18.00
15.55
15.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Malanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RWS Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/09/15

Date of
Testing

Weight
(Kg)

05/10/15

8.085
7.970
8.135

Failure
Load
(kN)
440
200
470

Compressive
Strength (MPa)
19.55
8.89
20.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities toMavathur and other


31 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/09/15

Date of
Testing

Weight
(Kg)

05/10/15

8.075
7.920
7.905

Failure
Load
(kN)
400
515
350

Compressive
Strength (MPa)
17.78
22.89
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Mavathur and other

31 villages of K.R. Nagar Taluk, Mysore district.


Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR-2 Column above GL Brace Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
29/09/15

Date of
Testing

Weight
(Kg)

05/10/15

7.580
7.870
7.750

Failure
Load
(kN)
200
250
255

Compressive
Strength (MPa)
8.89
11.11
11.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Mavathur and other


31 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Ramp House Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/09/15

Date of
Testing

Weight
(Kg)

05/10/15

8.210
8.350
8.015

Failure
Load
(kN)
430
570
340

Compressive
Strength (MPa)
19.11
25.33
15.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Malanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Anal Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
28/09/15

Date of
Testing

Weight
(Kg)

05/10/15

8.015
7.995
8.005

Failure
Load
(kN)
340
350
320

Compressive
Strength (MPa)
15.11
15.55
14.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Mavathur and other


31 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR-2 Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

09/09/15

05/10/15

8.280
8.120
7.985

Failure
Load
(kN)
610
450
435

Compressive
Strength (MPa)
27.11
20.00
19.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Mavathur and other


31 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR-2 GL Brace Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

27/09/15

05/10/15

7.785
7.865
7.840

Failure
Load
(kN)
300
320
270

Compressive
Strength (MPa)
13.33
14.22
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Malanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

13/09/15

05/10/15

8.100
7.955
8.215

300
300
270

13.33
13.33
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15

Project*

: Cauvery drinking water facilities to Malanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Wash water tank Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

15/09/15

05/10/15

8.445

Failure
Load
(kN)
400

Compressive
Strength (MPa)
17.78

2
3

---

8.280
8.025

360
340

16.00
15.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15934

Date: 07/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 03/10/15.

Project*

: Cauvery drinking water facilities to Mavathur and other


31 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR-1 Bprrom Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/09/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

05/10/15

8.125
8.095
7.845

Failure
Load
(kN)
615
550
595

Compressive
Strength (MPa)
27.33
24.44
26.44s

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15875

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/495 dated 22/09/15..

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F4 level roof slab concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

N4
N5
N6

25/08/15

22/09/15

8.225
8.280
8.455

Failure
Load
(kN)
695
680
695

Compressive
Strength (MPa)
30.89
30.22
30.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15875

Date: 24/09/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/494 dated 22/09/15..

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F4 level roof slab concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
700
710
700

1
P4
8.230
2
P5
25/08/15
22/09/15
8.205
3
P6
8.295
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
31.11
31.55
31.11

Testing officer

CRC No: 15949

Date: 10/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/520 dated 07/10/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F5 level roof slab concrete. 31.00 cum.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
650
660
630

1
P1
8.125
2
P2
30/09/15
08/10/15
8.150
3
P3
8.240
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
28.89
29.33
28.00

Testing officer

CRC No: 15950

Date: 10/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/521 dated 07/10/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F5 level roof slab concrete. 31.00 cum.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
530
515
530

1
Q1
8.210
2
Q2
30/09/15
08/10/15
8.230
3
Q3
8.300
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
23.55
22.89
23.55

Testing officer

CRC No: 15955

Date: 13/10/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Damden Solarium, KIADB Industrial Area,


Hebbal, Mysuru.

Ref No

: Letter dated 09/10/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, OHT and LMR.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/09/15

09/10/15

8.105
7.875
8.205

Failure
Load
(kN)
320
455
630

Compressive
Strength (MPa)
14.22
20.22
28.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15849

Date: 14/09/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/467 dated 11/09/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column concrete F5 level.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
520
535
550

Compressive
Strength (MPa)

1
P1
7.930
2
P2
04/09/15
12/09/15
7.965
3
P3
7.890
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

23.11
23.78
24.44

Testing officer

CRC No: 15943

Date: 08/10/15.
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,

Central PWD, Mysore.


Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/507 dated 28/09/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column concrete F5 level.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
550
595
600

Compressive
Strength (MPa)

1
P4
7.925
2
P5
04/09/15
06/10/15
7.985
3
P6
7.990
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

24.44
26.44
26.67

Testing officer

CRC No: 15772

Date: 28/08/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/432 dated 26/08/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column concrete F4 level.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
695
700
680

1
L4
8.145
2
L5
29/07/15
27/08/15
7.955
3
L6
7.985
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.89
31.11
30.72

Testing officer

CRC No: 15957

Date: 12/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: The Executive Engineer, Mysore Division, KPHC Ltd, Mysore

Contractor Name

: Sri. B.M Nataraju, Shankarapuram, Bangalore

Ref No

: Letter dated 09/10/15.

Project*

: Construction of Guest House for SI level Officers, Mysores

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6
7
8

---------

Date of
Casting

Date of
Testing

Weight
(Kg)

12/09/15

09/10/15

8.305
8.270
8.230
8.185
8.210
8.240
8.355
8.290

Failure
Load
(kN)
590
570
690
600
630
610
610
600

Compressive
Strength (MPa)
26.22
25.33
30.67
26.67
28.00
27.11
27.11
26.67

9
-8.165
500
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

22.22

Testing officer

CRC No: 15954

Date: 14/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 09/10/15.

Project*

: Sub Way

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
01/10/15

Date of
Testing

Weight
(Kg)

08/10/15

8.185
8.140
8.090

Failure
Load
(kN)
735
780
750

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
32.67
34.67
33.33

Testing officer

CRC No: 15954

Date: 14/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 09/10/15.

Project*

: Sub Way

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

29/09/15

08/10/15

8.285
8.225
8.260

Failure
Load
(kN)
800
830
850

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
35.55
36.89
37.79

Testing officer

CRC No: 15965

Date: 15/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 13/10/15.

Project*

: Sub Way

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/10/15

13/10/15

8.180
8.170
--

Failure
Load
(kN)
680
590
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
30.22
26.22
--

Testing officer

CRC No: 15966

Date: 15/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: KNK Swamy & Company, Jayanagar 4th Block, Bangalore.

Ref No

: Letter dated 13/10/15.

Project*

: M/s. SPR Distilleries, Pvt Ltd.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25G.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

06/10/15

13/10/15

8.100
8.220
8.250

Failure
Load
(kN)
590
560
610

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
26.22
24.89
27.11

Testing officer

CRC No: 15963

Date: 15/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Emgineer, KHB Mysurudivision, Mysuru.

Agency

: M/s Gadhiraju Constructions Pvt Ltd, Bangalore.

Ref No

: Letter dated 13/10/15.

Project*

: Construction of New RTO Office, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Slab concrete (First Floor)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
640
610
610

1
-8.325
15/09/15
13/10/15
2
-8.245
3
-8.175
Note:
1.* Informatin furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
28.44
27.11
27.11

3. Any correction invalidates this report.

Testing officer

CRC No: 15959

Date: 13/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 09/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

25/09/15

09/10/15

8.210
8.255
8.335

Failure
Load
(kN)
610
890
400

Compressive
Strength (MPa)
27.11
39.55
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15959

Date: 13/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 09/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
09/09/15

Date of
Testing

Weight
(Kg)

09/10/15

7.935
8.000
7.785

Failure
Load
(kN)
420
570
500

Compressive
Strength (MPa)
18.67
25.33
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15959

Date: 13/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 09/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

28/09/15

09/10/15

8.170
8.175
8.130

Failure
Load
(kN)
580
560
350

Compressive
Strength (MPa)
25.78
24.89
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15959

Date: 13/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 09/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/09/15

Date of
Testing

Weight
(Kg)

09/10/15

8.165
8.000
7.830

Failure
Load
(kN)
615
415
300

Compressive
Strength (MPa)
27.33
18.44
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15986

Date: 17/10/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: G. Shashidhar, D. Block, JP Nagar, Mysore.

Ref No

: Letter dated 16/10/15.

Project*

: Construction of mini Party Hall at No. 7, C block, JP nagar,


Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20. GF Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/08/15

31/08/15

7.720
7.680
7.670

Failure
Load
(kN)
290
255
290

Compressive
Strength (MPa)
12.89
11.33
12.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15983

Date: 17/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: B.K. Gangadhar, Contractor, Mysore.

Ref No

: Letter dated 15/10/15.

Project*

: B.K. Gangadhar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/09/15

15/10/15

8.270
8.180
8.180

Failure
Load
(kN)
595
580
620

Compressive
Strength (MPa)
26.44
25.78
27.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15983

Date: 17/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: B.K. Gangadhar, Contractor, Mysore.

Ref No

: Letter dated 15/10/15.

Project*

: B.K. Gangadhar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/09/15

15/10/15

8.270
8.200
8.140

Failure
Load
(kN)
750
780
700

Compressive
Strength (MPa)
33.33
34.67
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15989

Date: 19/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AV Constructions, (AVC/NC).

Ref No

: Letter dated 16/10/15.

Project*

: Construction of Neuro Care Centre @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RMC (Lafarge)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/09/15

Date of
Testing

Weight
(Kg)

17/10/15

8.310
8.235
8.305

Failure
Load
(kN)
670
650
630

Compressive
Strength (MPa)
29.78
28.89
28.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15971

Date: 17/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri Bindumadhava Religious Trust, Belaguru, Hosadurga Tq.

Ref No

: Letter dated 15/10/15.

Project*

: Sabha Bhavana, Belaguru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Ground Floor Roof.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

14/09/15

Date of
Testing

Weight
(Kg)

15/10/15

8.005
7.990
7.960
7.900
8.145
7.795

Failure
Load
(kN)
510
620
500
490
530
550

Compressive
Strength (MPa)
22.67
27.55
22.22
21.78
23.55
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15968

Date: 16/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Bangalore.

Ref No

: Letter dated 14/10/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, (Karnataka Readycon Mix Concrete),


Retaining wall Entry raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/09/15

Date of
Testing

Weight
(Kg)

14/10/15

8.195
8.205
8.335

Failure
Load
(kN)
550
530
510

Compressive
Strength (MPa)
24.44
23.55
22.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15973

Date: 17/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: The Executive Engineer, Mysore Division, KSPHC Ltd,


Mysore.

Ref No

: Letter dated 15/10/15.

Project*

: Construction of Guest House for SI Level Officers @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Plinth beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
08/10/15

Date of
Testing

Weight
(Kg)

15/10/15

7.970
8.135
8.120

Failure
Load
(kN)
670
510
635

Compressive
Strength (MPa)
29.78
22.67
28.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15981

Date: 17/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. KNK Swamy & Company, Jayanagar 4th Block,


Bangalore.

Ref No

: Letter dated 15/10/15.

Project*

: SPR Distilleries Pvt Ltd.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/10/15

15/10/15

8.265
8.215
8.200

Failure
Load
(kN)
605
540
550

Compressive
Strength (MPa)
26.89
24.00
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15969

Date: 16/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. KNK Swamy & Company, Jayanagar 4th Block,


Bangalore.

Ref No

: Letter dated 14/10/15.

Project*

: SPR Distilleries Pvt Ltd.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25F.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

07/10/15

14/10/15

8.165
8.450
8.400

640
630
600

28.44
28.00
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15991

Date: 20/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 17/10/15.

Project*

: Sub Way

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
22/09/15

Date of
Testing

Weight
(Kg)

20/10/15

8.225
8.210
--

Failure
Load
(kN)
1020
1020
--

Compressive
Strength (MPa)
45.33
45.33
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 15991

Date: 20/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 17/10/15.

Project*

: Sub Way

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/09/15

19/10/15

8.120
---

Failure
Load
(kN)
1050
---

Compressive
Strength (MPa)
46.67
---

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16002

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

03/10/15

20/10/15

8.020
8.345
8.160

Failure
Load
(kN)
620
720
460

Compressive
Strength (MPa)
27.55
32.00
20.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16002

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

11/09/15

20/10/15

7.970
8.065
8.070

Failure
Load
(kN)
840
850
800

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
37.33
37.78
35.55

3. Any correction invalidates this report.


Testing officer

CRC No: 16002

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/09/15

Date of
Testing

Weight
(Kg)

20/10/15

7.565
8.000
7.980

Failure
Load
(kN)
500
715
480

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.22
31.78
21.33

Testing officer

CRC No: 16002

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/09/15

20/10/15

8.120
8.090
8.250

Failure
Load
(kN)
350
750
450

Compressive
Strength (MPa)
15.55
33.33
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16002

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/09/15

Date of
Testing

Weight
(Kg)

20/10/15

8.085
8.200
8.280

Failure
Load
(kN)
810
550
700

Compressive
Strength (MPa)
36.00
24.44
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16002

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
22/09/15

Date of
Testing

Weight
(Kg)

20/10/15

8.175
8.180
7.875

Failure
Load
(kN)
600
870
580

Compressive
Strength (MPa)
26.67
38.67
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16002

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/10/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/10/15

20/10/15

7.970
8.040
8.070

Failure
Load
(kN)
450
650
720

Compressive
Strength (MPa)
20.00
28.89
32.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15998

Date: 21/10/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/10/15.

Project*

: Cauvery drinking water facilities to Mavathur and 31 villages


of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Avaler Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/09/15

Date of
Testing

Weight
(Kg)

20/10/15

7.830
7.800
7.735

Failure
Load
(kN)
200
270
245

Compressive
Strength (MPa)
8.89
12.00
10.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15998

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/10/15.

Project*

: Cauvery drinking water facilities to Malanayakanahalli and


other 42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Intake well side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/09/15

Date of
Testing

Weight
(Kg)

20/10/15

8.100
8.370
7.635

Failure
Load
(kN)
380
515
370

Compressive
Strength (MPa)
16.89
22.89
16.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15998

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/10/15.

Project*

: Cauvery drinking water facilities to Malanayakanahalli and


other 42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: RSF F/F Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/09/15

Date of
Testing

Weight
(Kg)

20/10/15

8.030
7.750
7.815

Failure
Load
(kN)
330
380
330

Compressive
Strength (MPa)
14.67
16.89
14.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15998

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/10/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 31


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: MBR-1 Column above bottom slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/09/15

Date of
Testing

Weight
(Kg)

20/10/15

7.695
7.830
7.660

Failure
Load
(kN)
270
320
250

Compressive
Strength (MPa)
12.00
14.22
11.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15998

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/10/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 31


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: MBR-1 Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

02/10/15

20/10/15

7.850
7.920
7.980

Failure
Load
(kN)
150
180
255

Compressive
Strength (MPa)
6.66
8.00
11.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15998

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/10/15.

Project*

: Cauvery drinking water facilities to Malanayakanahalli and 42


other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: RSF G/F Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/09/15

Date of
Testing

Weight
(Kg)

20/10/15

8.120
7.900
7.805

Failure
Load
(kN)
350
310
320

Compressive
Strength (MPa)
15.55
13.78
14.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15998

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/10/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 31


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: MBR-2, Ground level Brace.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/09/15

Date of
Testing

Weight
(Kg)

20/10/15

7.705
8.210
7.815

Failure
Load
(kN)
370
385
425

Compressive
Strength (MPa)
16.44
17.11
18.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15998

Date: 21/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 20/10/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 31


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: MBR2 Column Above 1st Brace.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/10/15

20/10/15

7.935
7.805
7.900

Failure
Load
(kN)
290
275
250

Compressive
Strength (MPa)
12.89
12.22
11.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16014

Date: 30/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&DB Board Division, Mysuru.

Ref No

: --

Project*

: Construction of Sump, pump house, chain link fencing and


allied works for IBPS-2, Supply and fixing of bulk flow meter
to feeder mains under Augmentation of water supply to
Mysuru city from Kabini River under Jn-NURM.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Sump Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

29/09/15

29/10/15

8.255
8.320
8.505

750
790
800

33.33
35.11
35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16022

Date: 31/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 30/10/15.

Project*

: Athmanandasagara Layout.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

20/10/15

30/10/15

8.350
8.200

Failure
Load
(kN)
760
860

Compressive
Strength (MPa)
33.78
38.22

--

8.245

900

40.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16011

Date: 30/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/566 dated 27/10/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F5 level roof slab concrete 31.00 cum.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
700
700
695

Compressive
Strength (MPa)

1
R4
8.340
2
R5
30/09/15
28/10/15
8.255
3
R6
8.350
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

31.11
31.11
30.89

Testing officer

CRC No: 16012

Date: 30/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/567 dated 27/10/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, F5 level roof slab concrete 31.00 cum.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
720
710
740

1
Q4
8.360
2
Q5
30/09/15
28/10/15
8.290
3
Q6
8.245
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
32.00
31.55
32.89

Testing officer

CRC No: 16027

Date: 31/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 30/10/15

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Slab 3rd Floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/10/15

30/10/15

8.125
8.105
8.205

Failure
Load
(kN)
400
400
390

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
17.78
17.78
17.33

3. Any correction invalidates this report.


Testing officer

CRC No: 16013

Date: 30/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 29/10/15

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Retaining wall Entry Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

30/09/15

29/10/15

8.305
8.140
8.280

Failure
Load
(kN)
900
800
940

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
40.00
35.55
41.78

Testing officer

CRC No: 15985

Date:19/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/P.Way/KRNR.

Ref No

: Letter dated 17/10/15.

Project*

: Mysore-Arisikere section : - Elimination of manned level


crossing No. 20 @ Km. 24/200-300 and 70 @ Km.
79/400-500 constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/09/15

Date of
Testing

Weight
(Kg)

16/10/15

7.690
8.010
7.690

Failure
Load
(kN)
830
800
805

Compressive
Strength (MPa)
36.89
35.55
35.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 15985

Date:19/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/P.Way/KRNR.

Ref No

: Letter dated 17/10/15.

Project*

: Mysore-Arisikere section : - Elimination of manned level


crossing No. 20 @ Km. 24/200-300 and 70 @ Km.
79/400-500 constructing of subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/09/15

16/10/15

7.585
7.810
7.895

Failure
Load
(kN)
825
795
800

Compressive
Strength (MPa)
36.67
35.33
35.56

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16010

Date: 30/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: KNK Swamy & Company, Jayanagar 4th Block, Bangalore.

Ref No

: Letter dated 28/10/15.

Project*

: M/s. SPR Distilleries, Pvt Ltd.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/10/15

28/10/15

8.245
8.280
8.250

Failure
Load
(kN)
670
700
680

Compressive
Strength (MPa)
29.78
31.11
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16010

Date: 30/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: KNK Swamy & Company, Jayanagar 4th Block, Bangalore.

Ref No

: Letter dated 28/10/15.

Project*

: M/s. SPR Distilleries, Pvt Ltd.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25F.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/10/15

Date of
Testing

Weight
(Kg)

28/10/15

8.190
8.255
8.240

Failure
Load
(kN)
850
750
730

Compressive
Strength (MPa)
37.78
33.33
32.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16010

Date: 30/10/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: KNK Swamy & Company, Jayanagar 4th Block, Bangalore.

Ref No

: Letter dated 28/10/15.

Project*

: M/s. SPR Distilleries, Pvt Ltd.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25G.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
06/10/15

Date of
Testing

Weight
(Kg)

28/10/15

8.195
8.230
8.240

Failure
Load
(kN)
780
750
850

Compressive
Strength (MPa)
34.67
33.33
37.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16028

Date: 02/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SNR Associates, Mysuru

Ref No

: Letter dated 31/10/15.

Project*

: Construction of Museum at Suttur.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20 (Site mix), plinth beams.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/09/15

31/10/15

8.245
8.210
8.070

Failure
Load
(kN)
450
350
350

Compressive
Strength (MPa)
20.00
15.55
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16041

Date: 04/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. KNK Swamy & Company Pvt Ltd, Jayanagar 4th Block,
Bangalore.

Ref No

: Letter dated 03/11/15.

Project*

: SPR Distilleries.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25G.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

06/10/15

03/11/15

8.215
8.190
8.335

Failure
Load
(kN)
740
840
730

Compressive
Strength (MPa)
32.89
37.33
32.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16037

Date: 04/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 03/11/15

Project*

: Subway

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
08/10/15

Date of
Testing

Weight
(Kg)

03/11/15

8.145
8.130
--

Failure
Load
(kN)
1000
1050
--

Compressive
Strength (MPa)
44.44
46.67
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16038

Date: 04/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 03/11/15

Project*

: Subway

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/10/15

Date of
Testing

Weight
(Kg)

03/11/15

8.170
8.175
--

Failure
Load
(kN)
610
640
--

Compressive
Strength (MPa)
27.11
28.44
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16044

Date: 06/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: KNK Swamy & Company, Jayanagar 4th Block, Bangalore.

Ref No

: Letter dated 04/11/15

Project*

: M/s. SPR Distilleries, Pvt Ltd.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25F.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/10/15

Date of
Testing

Weight
(Kg)

04/11/15

8.245
8.250
8.185

Failure
Load
(kN)
760
965
750

Compressive
Strength (MPa)
33.78
42.89
33.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16043

Date: 06/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 04/11/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Enry Ramp Retaining Wall (MSR Ready Mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/10/15

04/11/15

8.170
8.020
8.055

Failure
Load
(kN)
500
495
510

Compressive
Strength (MPa)
22.22
21.78
22.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16050

Date: 06/11/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: KNK Swamy & Company, Jayanagar 4th Block, Bangalore.

Ref No

: Letter dated 05/11/15

Project*

: M/s. SPR Distilleries, Pvt Ltd.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

08/10/15

05/11/15

8.295
8.320
8.275

Failure
Load
(kN)
840
840
785

Compressive
Strength (MPa)
37.33
37.33
34.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16055

Date: 09/11/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: SNR Associates, Krishnamurthy puram, Mysore.

Ref No

: Letter dated 07/11/15.

Project*

: Construction of Museum at Suttur,

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, (Site mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/10/15

Date of
Testing

Weight
(Kg)

07/11/15

7.980
7.800
7.980

Failure
Load
(kN)
350
420
250

Compressive
Strength (MPa)
15.55
18.67
11.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16055

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SNR Associates, Krishnamurthy puram, Mysore.

Ref No

: Letter dated 07/11/15.

Project*

: Construction of Museum at Suttur,

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, (Site mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/10/15

Date of
Testing

Weight
(Kg)

07/11/15

7.710
8.135
8.115

Failure
Load
(kN)
400
380
395

Compressive
Strength (MPa)
17.78
16.89
17.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16054

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 07/11/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 32


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Alum tank bottom slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/10/15

07/11/15

8.050
8.170
8.040

Failure
Load
(kN)
500
520
430

Compressive
Strength (MPa)
22.22
23.11
19.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16054

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 07/11/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 32

villages of K.R. Nagar Taluk, Mysore district.


Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: WWT Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/10/15

Date of
Testing

Weight
(Kg)

07/11/15

8.070
8.080
8.150

Failure
Load
(kN)
550
680
715

Compressive
Strength (MPa)
24.44
30.22
31.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16054

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 07/11/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 32


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: PWS Dome.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

31/10/15

07/11/15

7.615
7.610
7.585

Failure
Load
(kN)
200
200
190

Compressive
Strength (MPa)
8.89
8.89
8.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16054

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 07/11/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 32


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Brace beam MBR-2.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/10/15

Date of
Testing

Weight
(Kg)

07/11/15

7.710
7.890
7.905

Failure
Load
(kN)
400
380
410

Compressive
Strength (MPa)
17.78
16.89
18.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16054

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 07/11/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 32


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: MBR-1 Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3

----

: 150 mm x 150 mm x 150 mm


Date of
Casting
08/10/15

Date of
Testing

Weight
(Kg)

07/11/15

7.715
7.905
7.840

Failure
Load
(kN)
200
270
200

Compressive
Strength (MPa)
8.89
12.00
8.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16054

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 07/11/15.

Project*

: Cauvery drinking water facilities to Mavathur and other 32


villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: First floor lintel chejja.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

27/10/15

07/11/15

7.735
7.965
7.885

Failure
Load
(kN)
345
290
335

Compressive
Strength (MPa)
15.33
12.89
14.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16057

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 07/11/15

Project*

: Construction of layout Sapthamathruka-5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

10/09/15

07/11/15

7.285
8.295
7.520

500
425
600

22.22
18.89
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16057

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 07/11/15

Project*

: Construction of layout Sapthamathruka-5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

16/10/15

07/11/15

7.905
8.200
8.300

Failure
Load
(kN)
520
670
600

Compressive
Strength (MPa)
23.11
29.78
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16057

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 07/11/15

Project*

: Construction of layout Sapthamathruka-5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

25/10/15

07/11/15

7.680
7.980
7.325

Failure
Load
(kN)
500
700
750

Compressive
Strength (MPa)
22.22
31.11
33.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16057

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 07/11/15

Project*

: Construction of layout Sapthamathruka-5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
14/09/15

Date of
Testing

Weight
(Kg)

07/11/15

7.555
7.200
8.280

Failure
Load
(kN)
450
300
550

Compressive
Strength (MPa)
20.00
13.33
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16057

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 07/11/15

Project*

: Construction of layout Sapthamathruka-5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/10/15

Date of
Testing

Weight
(Kg)

07/11/15

8.120
7.965
8.500

Failure
Load
(kN)
510
540
450

Compressive
Strength (MPa)
22.67
24.00
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16057

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 07/11/15

Project*

: Construction of layout Sapthamathruka-5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/10/15

Date of
Testing

Weight
(Kg)

07/11/15

8.690
8.315
8.380

Failure
Load
(kN)
450
470
400

Compressive
Strength (MPa)
20.00
20.89
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16057

Date: 09/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 07/11/15

Project*

: Construction of layout Sapthamathruka-5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

31/10/15

07/11/15

8.420
8.475
8.385

Failure
Load
(kN)
670
800
700

Compressive
Strength (MPa)
29.78
35.55
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16059

Date: 13/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Vonodh Kumar, KM Doddi, Mandya.

Ref No

: Letter dated 07/11/15

Project*

: Bharathi Educational Trust.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

31/10/15

09/11/15

8.080
8.200
7.970

Failure
Load
(kN)
590
550
560

Compressive
Strength (MPa)
26.22
24.44
24.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16068

Date: 14/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: B.T.C Cold Storage, Thandi Industrial Area, Thandavapura.

Ref No

: Letter dated 13/11/15

Project*

: Construction of Cold Storage.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20 (Site mix)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

25/10/15

13/11/15

7.900
8.105
8.220

Failure
Load
(kN)
405
345
405

Compressive
Strength (MPa)
18.00
15.33
18.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16067

Date: 14/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri Bindumadhava Religious Trust, Belaguru, Hosadurga Tq.

Ref No

: Letter dated 13/11/15.

Project*

: Sabha Bhavana, Belaguru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: First Floor roof.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/11/15

13/11/15

7.655
7.850
7.805

Failure
Load
(kN)
305
415
350

Compressive
Strength (MPa)
13.55
18.44
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16072

Date: 14/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Unique Builders, Hebbal 2nd Stage, Mysore.

Ref No

: Letter dated 13/11/15.

Project*

: Residential Roof casting.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Roof Casting.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
-7.860
400
2
-05/11/15
13/11/15
7.960
430
3
-7.860
410
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

17.78
19.11
18.22

Testing officer

CRC No: 16069

Date: 14/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/614 dated 10/11/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*
concrete and waer tank bottom slab.

: M25, Mumty roof slab


13.50 cum.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


150 mm x 150 mm
Sl
No

ID No.

: 150 mm x

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
495
480
500

1
S1
8.085
2
S2
03/11/15
11/11/15
8.155
3
S3
8.215
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.00
21.33
22.22

Testing officer

CRC No: 16066


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sri. Appadurai. Class 1 A, Contractor, Cauvery Niravari


Nigam.

Ref No

: --

Project*

: Improvement to road from Bagali to Muguru Package No.


KS-08/05. Work Code: W-08-63-13

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15. CC

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
-8.015
490
2
-19/06/15
16/07/15
8.060
495
3
-8.000
470
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

21.78
22.00
20.89

Testing officer

CRC No: 16066


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sri. Appadurai. Class 1 A, Contractor, Cauvery Niravari


Nigam.

Ref No

: --

Project*

: Construction of pipe culvert at Ch. 800 mt.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, CC

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/06/15

Date of
Testing

Weight
(Kg)

16/07/15

8.110
8.100
8.085

Failure
Load
(kN)
480
475
475

Compressive
Strength (MPa)
21.33
21.11
21.11

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16079


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sri. Appadurai. Class 1 Contractor, Kollegala.

Ref No

: Your letter dated 24/05/2015.

Project*

: Aldur main road to BMK Hundi Road in Kollegala Taluk,


Package No. KS-08-05. Work Code LS-08-63-20

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15. CD works, abutment walls.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
480
490
500

1
1
7.980
2
2
22/05/15
19/06/15
7.990
3
3
8.000
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
21.33
21.78
22.22

3. Any correction invalidates this report.


Testing officer

CRC No: 16079


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sri. Appadurai. Class 1 Contractor, Kollegala.

Ref No

: Your letter dated 24/05/2015.

Project*

: Aldur main road to BMK Hundi Road in Kollegala Taluk,


Package No. KS-08-05. Work Code LS-08-63-20

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25. CD works, deck slab and bearing slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
698
700
680

1
1
8.000
2
2
19/06/15
16/07/15
8.150
3
3
8.120
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
31.00
31.11
30.22

Testing officer

CRC No: 16079


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sri. Appadurai. Class 1 Contractor, Kollegala.

Ref No

: Your letter dated 24/05/2015.

Project*

: Aldur main road to BMK Hundi Road in Kollegala Taluk,


Package No. KS-08-05. Work Code LS-08-63-20

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15. CD Works and Parapet walls.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
470
465
470

1
1
8.000
2
2
29/06/15
26/07/15
8.105
3
3
8.110
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.89
20.67
20.89

Testing officer

CRC No: 16088

Date: 18/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: MS Construction, Mysore.

Ref No

: Letter dated 17/11/15.

Project*

: Ideal Jawa Rotary School, Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Roof casting.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

19/10/15

17/11/15

8.450
8.340
8.280

Failure
Load
(kN)
700
630
650

Compressive
Strength (MPa)
31.11
28.00
28.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16080

Date: 17/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Homes & Spaces, Srirampura, Mysore.

Ref No

: Letter dated 16/11/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
06/11/15

Date of
Testing

Weight
(Kg)

16/11/15

7.845
8.050
8.030

Failure
Load
(kN)
400
380
410

Compressive
Strength (MPa)
17.78
16.89
18.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16076

Date: 17/11/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Senior Section Engineer (works), South Western Railway,


Mysore.

Ref No

: Letter No. 390/SW/MYS/15 dated 14/11/2015.

Project*

: RCC work for circular beam, conical slab, bottom dome, top
ring beam and cat walk in connection with construction of over
head tank at Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/11/15

16/11/15

8.135
---

Failure
Load
(kN)
350
---

Compressive
Strength (MPa)
15.55
---

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16085


TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: G. Nagesh, JE, CED-III, CCU, RMNH, Mysore.

Agency

: N. Vinodkumar, Contractor, Bangalore.

Ref No

: Your letter dated 06/11/2015.

Project*

: Recarpetting of Road & construction of Toilet for security


room new entrance gate, compound wall, cattle trap etc in the
open space of RMNH, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

02/11/15

Date of
Testing

Weight
(Kg)

09/11/15

8.100
8.210
8.045
8.090
8.095
8.005

Failure
Load
(kN)
640
640
630
590
600
600

Compressive
Strength (MPa)
28.44
28.44
28.00
26.22
26.67
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16090

Date: 20/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 18/11/15.

Project*

: JSS Layout (Arch work) Varuna Village, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Arch footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/11/15

18/11/15

8.080
7.975
7.625

Failure
Load
(kN)
325
310
300

Compressive
Strength (MPa)
14.44
13.78
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16106

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Venkatesh.A.K..

Ref No

: Letter dated 21/11/15.

Project*

: Ladies Hostel; Vokkaligara Sangha Mandya.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

17/10/15

21/11/15

8.260
8.160
8.335

Failure
Load
(kN)
700
780
770

Compressive
Strength (MPa)
31.11
34.67
34.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16107

Date: 23/11/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: Indian Estate, Mantikaythanahalli, Bogadi, Mysore.

Ref No

: Letter dated 21/11/15.

Project*

: Indian Estate.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/10/15

Date of
Testing

Weight
(Kg)

21/11/15

8.140
8.300
8.295

Failure
Load
(kN)
620
785
650

Compressive
Strength (MPa)
27.55
34.89
28.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16103

Date: 23/11/15
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: Royal Concorde International School, Bogadi, Mysore.

Ref No

: Letter dated 21/11/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, II Floor Slab Beams.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

13/11/15

21/11/15

Weight
(Kg)
8.355
8.170
8.230

Failure Load
(kN)
550
480
500

Compressive
Strength (MPa)
24.44
21.33
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16104

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 21/11/15.

Project*

: Subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/10/15

21/11/15

8.170
8.100
--

Failure
Load
(kN)
1000
1000
--

Compressive
Strength (MPa)
44.44
44.44
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16105

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 21/11/15.

Project*

: Subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/10/15

Date of
Testing

Weight
(Kg)

23/11/15

8.095
8.110
--

Failure
Load
(kN)
800
1000
--

Compressive
Strength (MPa)
35.55
44.44
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16102

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/11/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

03/10/15

20/11/15

8.235
8.415
8.370

Failure
Load
(kN)
650
730
750

Compressive
Strength (MPa)
28.89
32.44
33.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16102

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/11/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/09/15

20/11/15

8.400
8.225
8.345

Failure
Load
(kN)
670
720
730

Compressive
Strength (MPa)
29.78
32.00
32.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16102

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/11/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

09/10/15

20/11/15

7.915
8.120
8.170

Failure
Load
(kN)
575
540
750

Compressive
Strength (MPa)
25.55
24.00
33.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16102

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/11/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
21/10/15

Date of
Testing

Weight
(Kg)

20/11/15

8.265
8.190
8.020

Failure
Load
(kN)
620
545
620

Compressive
Strength (MPa)
27.55
24.22
27.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16102

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/11/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

19/10/15

20/11/15

7.760
7.790
7.945

Failure
Load
(kN)
395
390
445

Compressive
Strength (MPa)
17.55
17.33
19.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16102

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/11/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

03/11/15

20/11/15

8.125
8.020
8.290

Failure
Load
(kN)
550
560
520

Compressive
Strength (MPa)
24.44
24.89
23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16102

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/11/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

23/09/15

20/11/15

8.240
8.245
8.165

660
855
770

29.33
38.00
34.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16102

Date: 23/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 20/11/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

25/09/15

20/11/15

8.490

Failure
Load
(kN)
960

Compressive
Strength (MPa)
42.67

2
3

---

8.440
8.305

1000
900

44.44
40.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16113

Date: 25/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: KNK Swamy & Company, Jayanagar 4th Block, Bangalore.

Ref No

: Letter dated 23/11/15.

Project*

: M/s. SPR Distilleries, Pvt Ltd.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/11/15

Date of
Testing

Weight
(Kg)

23/11/15

8.130
8.090
8.170

Failure
Load
(kN)
530
550
510

Compressive
Strength (MPa)
23.55
24.44
22.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16117

Date: 26/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd Stage, BEML Layout, Mysore.

Ref No

: Letter dated 24/11/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

15/11/15

24/11/15

7.875
7.885

Failure
Load
(kN)
510
490

Compressive
Strength (MPa)
22.67
21.78

--

7.900

510

22.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16121

Date: 26/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 25/11/15.

Project*

: Subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

18/11/15

25/11/15

8.180
8.200
--

Failure
Load
(kN)
580
540
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
25.78
24.00
--

3. Any correction invalidates this report.

Testing officer

CRC No: 16120

Date: 26/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 25/11/15.

Project*

: Subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

30/10/15

25/11/15

8.265
8.265
--

Failure
Load
(kN)
630
630
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
28.00
28.00
--

3. Any correction invalidates this report.

Testing officer

CRC No: 16122

Date: 26/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 25/11/15.

Project*

: JSS Layout Arch, Varuna, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Padastral Couereting.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/11/15

Date of
Testing

Weight
(Kg)

25/11/15

/.180
7.935
8.260

Failure
Load
(kN)
380
400
410

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
16.89
17.78
18.22

Testing officer

CRC No: 16131

Date: 30/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Royal Concorde International School, Bogadi, Mysore.

Ref No

: Letter dated 27/11/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, II Floor Slab & Beams.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

13/11/15

27/11/15

Weight
(Kg)
7.720
7.815
7.830

Failure Load
(kN)
410
475
455

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
18.22
21.11
20.22

3. Any correction invalidates this report.


Testing officer

CRC No: 16136

Date: 30/11/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, JNNURM, MCC, Mysore.

Ref No

: Letter No. MCC/JNNURM/AEE-4//2015-16 dated 27/11/15.

Project*

: Multi level parking @ Townhall, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Slab and Beam Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/11/15

Date of
Testing

Weight
(Kg)

27/11/15

8.160
8.410
8.205

Failure
Load
(kN)
400
725
700

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
17.78
32.22
31.11

Testing officer

CRC No: 16145

Date: 03/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd Stage, BEML Layout, Mysore.

Ref No

: Letter dated 01/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/11/15

01/12/15

7.995
8.190
7.910

Failure
Load
(kN)
800
610
430

Compressive
Strength (MPa)
35.55
27.11
19.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16146

Date: 03/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 01/12/15.

Project*

: Work of drinking water at Mavathur & 32 other villages


of KR Nagar Taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Alum Tank Bottom Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/10/15

Date of
Testing

Weight
(Kg)

01/12/15

8.210
8.005
8.265

Failure
Load
(kN)
570
500
480

Compressive
Strength (MPa)
25.33
22.22
21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16146

Date: 03/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 01/12/15.

Project*

: Work of drinking water at Mavathur & 32 other villages


of KR Nagar Taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, PWS Dome.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
31/10/15

Date of
Testing

Weight
(Kg)

01/12/15

7.510
7.500
7.550

Failure
Load
(kN)
300
230
230

Compressive
Strength (MPa)
13.33
10.22
10.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16146

Date: 03/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 01/12/15.

Project*

: Work of drinking water at Malanayakanahalli & 42 villages


of KR Nagar taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Wash Water Tank Dome

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/11/15

Date of
Testing

Weight
(Kg)

01/12/15

7.870
7.805
7.890

Failure
Load
(kN)
310
270
285

Compressive
Strength (MPa)
13.78
12.00
12.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16146

Date: 03/12/15
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 01/12/15.

Project*

: Work of drinking water at Mavathur & 32 other villages


of KR Nagar Taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, First Floor lintel Chejja.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

27/10/15

01/12/15

7.805
7.875
7.850

Failure
Load
(kN)
170
380
185

Compressive
Strength (MPa)
7.55
16.89
8.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16146

Date: 03/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 01/12/15.

Project*

: Work of drinking water at Mavathur & 32 other villages


of KR Nagar Taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Brace beam 2.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/11/15

Date of
Testing

Weight
(Kg)

01/12/15

8.030
7.935
7.960

Failure
Load
(kN)
250
230
230

Compressive
Strength (MPa)
11.11
10.22
10.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16146

Date: 03/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 01/12/15.

Project*

: Work of drinking water at Mavathur & 32 other villages


of KR Nagar Taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column above brace beam 1.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/11/15

01/12/15

7.965
7.790
7.830

Failure
Load
(kN)
300
310
325

Compressive
Strength (MPa)
13.33
13.78
14.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16161

Date: 04/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE/Works, South Western Railway, Mysore.

Ref No

: Letter No. 390/SW/MYS/15 dated 14/11/15

Project*

: Mysuru-Improvements to Watering arrangements at Station,


RCC work for circkular beam, conical beam, concial slab,

bottom dome, top ring and cat wal in connection with


construction of over head tank at Mysore.
Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/11/15

03/12/15

7.990
7.850
--

Failure
Load
(kN)
830
770
--

Compressive
Strength (MPa)
36.89
34.22
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16156

Date: 04/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. BTC Cold Storage, Tandavapura village, Nanjangud.

Ref No

: Letter dated 03/12/15.

Project*

: Cold Storage.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

25/10/15

03/12/15

8.095
8.025
7.905

Failure
Load
(kN)
350
505
350

Compressive
Strength (MPa)
15.55
22.44
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16158

Date: 04/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Unique Builders, Myosre-17.

Ref No

: Letter dated 03/12/15.

Project*

: Residential Roof casting.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Roof.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

: 150 mm x 150 mm x 150 mm


Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
720
650
600

Compressive
Strength (MPa)

1
-8.230
2
-05/11/15
03/12/15
8.090
3
-7.725
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

32.00
28.89
26.67

Testing officer

CRC No: 16160

Date: 04/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AV Constructions, (AVC/NC).

Ref No

: Letter dated 03/12/15.

Project*

: Construction of Neuro Care Centre @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RMC (Lafarge)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/11/15

03/12/15

8.215
8.075
8.000

Failure
Load
(kN)
430
385
300

Compressive
Strength (MPa)
19.11
17.11
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16179

Date: 09/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 07/12/15.

Project*

: Proposed Saptha-5 Layout.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

01/12/15

07/12/15

8.180
8.590
7.860

Failure
Load
(kN)
300
310
315

Compressive
Strength (MPa)
13.33
13.78
14.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16179

Date: 09/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 07/12/15.

Project*

: Proposed Saptha-5 Layout.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

30/11/15

07/12/15

8.370
8.250
8.020

Failure
Load
(kN)
350
390
380

Compressive
Strength (MPa)
15.56
17.33
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16171

Date: 07/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 04/12/15.

Project*

: Subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/11/15

04/12/15

8.405
8.280
--

Failure
Load
(kN)
690
675
--

Compressive
Strength (MPa)
30.67
30.00
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16149

Date: 04/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Engineer, Mysore Central Sub division-II,


Central PWD, Mysore.

Ref No

: Letter No. 25(7)(2)/MCSD-/II/2015/671 dated 02/12/15.

Project*

: Construction of EMQ (Essential Maintanence Quarters for


CPWD staff at GPRA Campus in Mysore. SH: C/o 8 Nos
Type-III Qtrs in one block of ground plus three upper floors i/c
internal water supply, sanitary sanitation internal electrical
installations, drainage, external water supply lines approach
path way and c/o one scooter shed for 8 nos scooters.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Mumty roof slab & water tank concrete. 13.50 cum.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
650
650
660

Compressive
Strength (MPa)

1
S4
8.340
2
S5
04/11/15
02/12/15
8.130
3
S6
8.210
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

28.89
28.89
29.33

Testing officer

CRC No: 16177

Date: 09/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Homes & Spaces, Srirampura 2nd Stage,


BEML Layout, Mysore.

Ref No

: Letter dated 07/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

09/11/15

07/12/15

7.965
8.020
7.945

480
480
550

21.33
21.33
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16176

Date: 09/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri Bindumadhava Religious Trust, Belaguru, Hosadurga Tq.

Ref No

: Letter dated 07/12/15.

Project*

: Sabha Bhavana, Belaguru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

04/11/15

07/12/15

7.800

Failure
Load
(kN)
460

Compressive
Strength (MPa)
20.44

2
3

---

8.045
7.875

560
580

24.89
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16188

Date: 10/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 09/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
03/11/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

09/12/15

8.075
8.200
8.285

Failure
Load
(kN)
600
530
720

Compressive
Strength (MPa)
26.67
23.55
32.00

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16188

Date: 10/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 09/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/11/15

09/12/15

8.445
8.300
8.320

Failure
Load
(kN)
500
380
300

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
22.22
16.89
13.33

Testing officer

CRC No: 16188

Date: 10/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 09/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
28/11/15

Date of
Testing

Weight
(Kg)

09/12/15

8.335
8.425
8.440

Failure
Load
(kN)
400
420
360

Compressive
Strength (MPa)
17.78
18.67
16.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16184

Date: 12/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 08/12/15.

Project*

: Work of drinking water at Malanayakanahalli & 42 other


villages of KR Nagar taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pure water sump Dome.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

06/11/15

08/12/15

8.125
8.170
8.205

Failure
Load
(kN)
360
380
490

Compressive
Strength (MPa)
16.00
16.89
21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16184

Date: 12/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 08/12/15.

Project*

: Work of drinking water at Malanayakanahalli & 42 other


villages of KR Nagar taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Wash water tank bottom slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
08/11/15

Date of
Testing

Weight
(Kg)

08/12/15

7.870
7.865
7.825

Failure
Load
(kN)
345
320
335

Compressive
Strength (MPa)
15.33
14.22
14.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16184

Date: 12/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 08/12/15.

Project*

: Work of drinking water at Malanayakanahalli & 42 other


villages of KR Nagar taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RSF First floor lintle.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

09/11/15

08/12/15

7.825
7.890
7.760

Failure
Load
(kN)
370
380
330

Compressive
Strength (MPa)
16.44
16.89
14.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16184

Date: 12/12/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 08/12/15.

Project*

: Work of drinking water at Malanayakanahalli & 42 other


villages of KR Nagar taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Alum Tank bottom slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
10/11/15

Date of
Testing

Weight
(Kg)

08/12/15

8.110
8.020
7.980

Failure
Load
(kN)
355
300
290

Compressive
Strength (MPa)
15.78
13.33
12.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16184

Date: 12/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 08/12/15.

Project*

: Work of drinking water at Mavathur & other 32 villages


of KR Nagar taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 2 Columns above brace beam 2.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/12/15

Date of
Testing

Weight
(Kg)

09/12/15

8.035
8.055
8.180

Failure
Load
(kN)
320
255
270

Compressive
Strength (MPa)
14.22
11.33
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16184

Date: 12/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 08/12/15.

Project*

: Work of drinking water at Mavathur & other 32 villages


of KR Nagar taluk, Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 2 brace beam 3

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/12/15

12/12/15

8.175
8.095
8.060

Failure
Load
(kN)
160
150
150

Compressive
Strength (MPa)
7.11
6.67
6.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16184

Date: 12/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: Letter dated 08/12/15.

Project*

: Work of drinking water at Mavathur & other 32 villages

of KR Nagar taluk, Mysore District.


Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 2 Brace beam 2.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/11/15

Date of
Testing

Weight
(Kg)

08/12/15

8.295
8.125
8.415

Failure
Load
(kN)
650
420
400

Compressive
Strength (MPa)
28.89
18.67
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16181

Date: 10/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Royal Concorde International School, Bogadi, Mysore.

Ref No

: Letter dated 08/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, Swimming Pool Bottom Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

29/11/15

08/12/15

Weight
(Kg)
8.330
8.350
--

Failure Load
(kN)
480
500
--

Compressive
Strength (MPa)
21.33
22.22
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16182

Date: 10/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Mata Amrithanandamayi Math, Bogadi, Mysore.

Ref No

: Letter dated 08/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Column Footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

02/12/15

08/12/15

Weight
(Kg)
8.025
7.870
8.010

Failure Load
(kN)
310
320
300

Compressive
Strength (MPa)
13.78
14.22
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16207

Date: 15/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd Stage,


BEML Layout, Mysore.

Ref No

: Letter dated 14/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

13/11/15

15/12/15

8.060
7.960
8.025

Failure
Load
(kN)
600
600
510

Compressive
Strength (MPa)
26.67
26.67
22.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16205

Date: 14/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 12/12/15

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Retaining Wall Entry Raft west side second lift


(MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/12/15

12/12/15

8.060
8.070
8.055

Failure
Load
(kN)
500
470
485

Compressive
Strength (MPa)
22.22
20.89
21.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16203

Date: 14/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 12/12/15.

Project*

: Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

05/12/15

12/12/15

8.220
8.110
--

420
420
--

18.67
18.67
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16211

Date: 18/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Royal Concorde International School, Bogadi, Mysore.

Ref No

: Letter dated 14/12/15.

Project*

: Royal Concorde International School, Bogadi 2nd Stage,


Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35, (Second Floor Slab).

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

13/11/15

15/12/15

8.335
8.265
8.170

820
800
730

36.44
35.56
32.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16225

Date: 19/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri Bindumadhava Religious Trust, Belaguru, Hosadurga Tq.

Ref No

: --

Project*

: Sabha Bhavana, Belaguru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Column 2nd floor.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

18/11/15

17/12/15

8.165
8.260

Failure
Load
(kN)
1000
850

Compressive
Strength (MPa)
44.44
37.78

--

8.100

500

22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16222

Date: 18/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 16/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/11/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

16/12/15

8.280
8.325
8.160

Failure
Load
(kN)
470
650
590

Compressive
Strength (MPa)
20.89
28.89
26.22

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16222

Date: 18/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 16/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
14/11/15

Date of
Testing

Weight
(Kg)

16/12/15

8.265
8.200
8.245

Failure
Load
(kN)
460
470
340

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.44
20.89
15.11

Testing officer

CRC No: 16222

Date: 18/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 16/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/12/15

12/12/15

8.185
8.185
8.220

Failure
Load
(kN)
240
230
270

Compressive
Strength (MPa)
10.66
10.22
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16229


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 06/10/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, For P2, 2nd Floor for column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
08/09/15

Date of
Testing

Weight
(Kg)

17/12/15

7.670
7.625
7.725

Failure
Load
(kN)
410
530
430

Compressive
Strength (MPa)
18.22
23.56
19.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16229


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 27/10/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, for P2 2nd floor slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

29/09/15

17/12/15

7.820
7.770
7.850

Failure
Load
(kN)
570
520
540

Compressive
Strength (MPa)
25.33
23.11
24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16229


TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 04/11/15.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, for P2, 3rd floor column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/10/15

Date of
Testing

Weight
(Kg)

17/12/15

8.065
8.080
7.945

Failure
Load
(kN)
630
670
540

Compressive
Strength (MPa)
28.00
29.97
24.0

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16220

Date: 18/12/15

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 14/12/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, West side Enry Ramp first lift Retaining Wall


(MSR READYCON Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/11/15

Date of
Testing

Weight
(Kg)

16/12/15

7.990
8.025
7.855

Failure
Load
(kN)
500
560
420

Compressive
Strength (MPa)
22.22
24.89
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16243

Date: 21/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Homes & Spaces, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 22/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
12/12/15

Date of
Testing

Weight
(Kg)

19/12/15

7.785
7.665
7.820

Failure
Load
(kN)
400
480
600

Compressive
Strength (MPa)
17.78
21.33
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16250

Date: 23/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Homes & Spaces, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 22/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

24/11/15

22/12/15

8.130
8.100
8.245

Failure
Load
(kN)
700
785
650

Compressive
Strength (MPa)
31.11
34.89
28.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16262

Date: 28/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AV Constructions, (AVC/NC).

Ref No

: Letter dated 24/12/15.

Project*

: Construction of Neuro Care Centre @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RMC (Lafarge)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
26/11/15

Date of
Testing

Weight
(Kg)

26/12/15

8.230
8.060
8.200

Failure
Load
(kN)
510
550
610

Compressive
Strength (MPa)
22.67
24.44
27.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16264

Date: 28/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 26/12/15.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, grid no. 11,Oti 2,H south,east side second floor roof

slab concrete. (MSR READYCON MIX Concrete)


Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

19/12/15

26/12/15

8.220
8.340
8.245

Failure
Load
(kN)
390
385
385

Compressive
Strength (MPa)
17.33
17.11
17.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16268

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 22/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/12/15

Date of
Testing

Weight
(Kg)

28/12/15

8.145
8.000
8.015

Failure
Load
(kN)
680
765
720

Compressive
Strength (MPa)
30.22
34.00
32.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16273

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: R. Ajith, Chamundipuram, Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: Commercial Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
26/11/15

Date of
Testing

Weight
(Kg)

28/12/15

8.275
8.105
8.135

Failure
Load
(kN)
530
615
515

Compressive
Strength (MPa)
23.55
27.33
22.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16274

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

21/11/15

28/12/15

8.290
8.180
8.395

750
410
730

33.33
18.22
32.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16274

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

28/11/15

28/12/15

8.500
8.435
8.580

510
400
550

22.67
17.78
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16274

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

11/12/15

28/12/15

8.100
8.205

Failure
Load
(kN)
450
520

Compressive
Strength (MPa)
20.00
23.11

--

8.545

540

24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16274

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
26/11/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

28/12/15

8.600
8.240
8.300

Failure
Load
(kN)
600
475
480

Compressive
Strength (MPa)
26.67
21.11
21.33

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16269

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: Construction of Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/12/15

28/12/15

8.500
8.410
8.425

Failure
Load
(kN)
1000
1000
1020

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
44.44
44.44
45.33

Testing officer

CRC No: 16269

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: Construction of Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/12/15

Date of
Testing

Weight
(Kg)

28/12/15

8.500
8.410
8.425

Failure
Load
(kN)
1050
1050
1020

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
46.67
46.67
45.33

Testing officer

CRC No: 16269

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: Construction of Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/12/15

Date of
Testing

Weight
(Kg)

28/12/15

8.500
8.410
8.425

Failure
Load
(kN)
1100
1080
1080

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
48.89
48.00
48.00

Testing officer

CRC No: 16270

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: Construction of Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/12/15

Date of
Testing

Weight
(Kg)

28/12/15

8.040
8.105
8.195

Failure
Load
(kN)
810
650
855

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
36.00
28.89
38.00

Testing officer

CRC No: 16263

Date: 28/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M.L. Sudha, CFTRI Layout, Mysore.

Ref No

: Letter dated 26/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20 Ready Mix Concrete, Column Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 10000 mm2

Size of the Specimen

: 100 mm x 100 mm x 100 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/12/15

Date of
Testing

Weight
(Kg)

26/12/15

2.220
2.230
--

Failure
Load
(kN)
250
270
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
2.5
2.7
--

Testing officer

CRC No: 16290

Date: 01/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Mata Amrithanandamayi Math, Bogadi, Mysore.

Ref No

: Letter dated 31/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

01/12/15

31/12/15

Weight
(Kg)
7.890
8.010
7.650

Failure Load
(kN)
450
500
475

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.00
22.22
21.11

Testing officer

CRC No: 16283

Date: 01/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, Zone-2, MUDA, Mysore.

Ref No

: Letter No. MUDA/AEE/Zone-2/2015-16 dated 27/11/15.

Project*

: Construction of gas furnace crematorium and development of


existing grave yard in JCST K block (near Cauvery School),
Kuvempunagr, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

22/12/15

30/12/15

Weight
(Kg)
7.835
7.885
7.875

Failure Load
(kN)
382
400
400

Compressive
Strength (MPa)
16.97
17.78
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16292

Date: 04/01/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 02/01/16.

Project*

: Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/12/15

Date of
Testing

Weight
(Kg)

02/01/16

8.170
8.220
--

Failure
Load
(kN)
1020
1000
--

Compressive
Strength (MPa)
45.33
44.44
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16313

Date: 29/12/15
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 05/01/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

25/12/15

05/01/16

8.055
8.015
8.095

Failure
Load
(kN)
785
640
750

Compressive
Strength (MPa)
34.89
28.44
33.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16310

Date: 06/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 05/01/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, second floor north east roof slab concrete.


(Gird 2H to 11A) MSR Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

30/12/15

05/01/16

8.320
8.095
8.140

Failure
Load
(kN)
270
350
460

Compressive
Strength (MPa)
12.00
15.55
20.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16309

Date: 06/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Simplex Infrastructure Limited, KRS Road,


Hulikere Village, Srirangapatna Taluk.

Ref No

: Letter No. Simplex/NIE/C2957/PM/163 dated 05/01/16.

Project*

: Zuari Garden City.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30,

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
28/12/15

Date of
Testing

Weight
(Kg)

05/01/16

8.045
8.090
8.010

Failure
Load
(kN)
600
580
580

Compressive
Strength (MPa)
26.67
25.78
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16298/A

Date: 06/01/16

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Sri Ranga Fashion, Chamundipuram, Mysore.

Ref No

: Letter dated 04/01/16.

Project*

: Commercial Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/12/15

Date of
Testing

Weight
(Kg)

04/01/16

8.120
8.140
8.065

Failure
Load
(kN)
420
400
380

Compressive
Strength (MPa)
18.67
17.78
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16296

Date: 06/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 02/01/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, West side Entry Ramp Retaining Wall concrete,


MSR READYCON MIX Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/12/15

Date of
Testing

Weight
(Kg)

04/01/16

7.990
8.125
7.755

Failure
Load
(kN)
650
700
620

Compressive
Strength (MPa)
28.89
31.11
27.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16315

Date: 06/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 05/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/12/15

05/01/16

8.025
8.010
7.955

Failure
Load
(kN)
500
620
540

Compressive
Strength (MPa)
22.22
27.55
24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16271

Date: 05/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Government Employees House Building Co-operative Society


Ltd., Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

28/12/15

04/01/16

Weight
(Kg)
8.160
8.210
8.330

Failure Load
(kN)
600
600
590

Compressive
Strength (MPa)
26.67
26.67
26.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16298

Date: 06/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: L. Ravichandran, Constractor, Shivanasamudra.


(KPCL)

Ref No

: Letter dated 23/12/15.

Project*

: Construction of Bituminour road, pathway, drains and culverts


for 10MW Solar power plant of KPCL at Belakavadi, Mandya
district, Karnataka.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

--

04/01/16

Weight
(Kg)
7.400
8.100
7.890

Failure Load
(kN)
375
675
900

Compressive
Strength (MPa)
16.67
30.00
40.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16307

Date: 06/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 04/01/16.

Project*

: Proposed layout at Saptha 5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/11/15

Date of
Testing

Weight
(Kg)

02/01/16

8.035
8.150
8.150

Failure
Load
(kN)
840
970
600

Compressive
Strength (MPa)
37.33
43.11
26.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16307

Date: 06/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 04/01/16.

Project*

: Proposed layout at Saptha 5.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
01/12/15

Date of
Testing

Weight
(Kg)

04/01/16

7.920
8.110
8.275

Failure
Load
(kN)
500
640
570

Compressive
Strength (MPa)
22.22
28.44
25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16307

Date: 06/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: VLR Infracon, Bangalore.

Ref No

: Letter dated 04/01/16.

Project*

: Proposed layout at Athmanandasagara.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/12/15

Date of
Testing

Weight
(Kg)

04/01/16

8.225
8.165
8.480

Failure
Load
(kN)
720
660
660

Compressive
Strength (MPa)
32.00
29.33
29.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16322

Date: 07/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 06/01/16.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/12/15

06/01/16

8.040
8.340
8.470

Failure
Load
(kN)
580
520
545

Compressive
Strength (MPa)
25.78
23.11
24.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16293

Date: 07/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 06/01/16.

Project*

: Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/12/15

Date of
Testing

Weight
(Kg)

06/01/16

8.475
8.415
--

Failure
Load
(kN)
1100
1140
--

Compressive
Strength (MPa)
48.89
50.67
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16321

Date: 07/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 06/01/16.

Project*

: Sub way.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3

----

: 150 mm x 150 mm x 150 mm


Date of
Casting
31/12/15

Date of
Testing

Weight
(Kg)

06/01/16

8.210
8.230
--

Failure
Load
(kN)
590
625
--

Compressive
Strength (MPa)
26.22
27.78
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16327

Date: 08/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client
: Assistant Executive Engineer, KUWSA&DB,
Sub division, Mysore.
Ref No

: Letter dated 07/01/16.

Project*

: Construction of Head Works, Providing MS transmission main


and alied works under providing Water Supply scheme to
BARC near Ilwala with Cauvery as source under DC Work.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Jack well Raft Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
31/12/15

Date of
Testing

Weight
(Kg)

07/01/16

8.440
8.250
8.210

Failure
Load
(kN)
320
410
380

Compressive
Strength (MPa)
14.22
18.22
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16325

Date: 08/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 07/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
31/12/15

Date of
Testing

Weight
(Kg)

07/01/16

8.060
7.960
8.070

Failure
Load
(kN)
400
625
500

Compressive
Strength (MPa)
17.78
27.78
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16325

Date: 08/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 07/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

30/12/15

07/01/16

8.055
7.825
7.815

Failure
Load
(kN)
500
450
450

Compressive
Strength (MPa)
22.22
20.00
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16332

Date: 09/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 08/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

01/01/16

08/01/16

8.045
8.130
8.250

Failure
Load
(kN)
400
450
480

Compressive
Strength (MPa)
17.78
20.00
21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16329

Date: 09/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 08/01/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

30/12/15

08/01/16

8.010
8.085
8.335

885
860
680

39.33
38.22
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16335

Date: 11/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 09/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

02/01/16

09/01/16

7.745

Failure
Load
(kN)
400

Compressive
Strength (MPa)
17.78

2
3

---

7.915
7.865

510
350

22.67
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16336

Date: 11/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 09/01/16.

Project*

: JSS Layout arch work Varuna Village, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, For arch footing concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/11/15

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

09/01/16

7.770
7.900
7.615

Failure
Load
(kN)
550
455
550

Compressive
Strength (MPa)
24.44
20.22
24.44

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16336

Date: 11/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 09/01/16.

Project*

: JSS Layout arch work Varuna Village, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, For arch column concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
17/11/15

Date of
Testing

Weight
(Kg)

09/01/16

8.145
7.835
8.010

Failure
Load
(kN)
500
780
580

Compressive
Strength (MPa)
22.22
34.67
25.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16339

Date: 12/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 11/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5

------

Date of
Casting

Date of
Testing

Weight
(Kg)

04/11/15

11/01/16

7.640
7.870
7.855
7.735
8.000

Failure
Load
(kN)
550
655
410
500
550

Compressive
Strength (MPa)
24.44
29.11
18.22
22.22
24.44

--

7.615

450

20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16343

Date: 12/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Shri Vishnu Constructions, Mysore.

Ref No

: Letter dated 11/01/16.

Project*

: Farm House Jodupala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
31/12/15

Date of
Testing

Weight
(Kg)

11/01/16

7.930
8.065
7.900

Failure
Load
(kN)
250
270
270

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
11.11
12.00
12.00

Testing officer

CRC No: 16348

Date: 13/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 12/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/01/16

Date of
Testing

Weight
(Kg)

12/01/16

8.260
8.130
8.260

Failure
Load
(kN)
650
410
590

Compressive
Strength (MPa)
28.89
18.22
26.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16353

Date: 14/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 13/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footings.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
01/01/16

Date of
Testing

Weight
(Kg)

13/01/16

8.065
8.305
7.920

Failure
Load
(kN)
550
500
480

Compressive
Strength (MPa)
24.44
22.22
21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16362

Date: 14/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 14/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footings.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

07/01/16

Date of
Testing

Weight
(Kg)

14/01/16

8.820
8.440
8.200
8.230
8.380
8.155

Failure
Load
(kN)
500
535
500
660
600
510

Compressive
Strength (MPa)
22.22
23.78
22.22
29.33
26.67
22.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16358

Date: 14/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Mysore.

Ref No

: Letter dated 13/01/16.

Project*

: JSS Layout Culvert work, Varuna Village, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, For culvert concrete work.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
01/01/16

Date of
Testing

Weight
(Kg)

13/01/16

7.610
7.480
7.220

Failure
Load
(kN)
200
250
240

Compressive
Strength (MPa)
8.89
11.11
10.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing officer

CRC No: 16361

Date: 14/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 14/01/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
06/01/16

Date of
Testing

Weight
(Kg)

14/01/16

8.140
8.085
8.095

Failure
Load
(kN)
620
920
710

Compressive
Strength (MPa)
27.55
40.89
31.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing officer

CRC No: 16386

Date: 20/01/16

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 19/01/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/12/15

Date of
Testing

Weight
(Kg)

19/01/16

7.995
8.040
7.950

Failure
Load
(kN)
920
980
940

Compressive
Strength (MPa)
40.89
43.55
41.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16394

Date: 20/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AV Constructions, (AVC/NC).

Ref No

: Letter dated 20/01/16.

Project*

: Construction of Neuro Care Centre @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RMC (Lafarge)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

13/01/16

19/01/16

8.260
8.295
8.230

Failure
Load
(kN)
515
450
480

Compressive
Strength (MPa)
22.89
20.00
21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16408

Date: 22/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sagar Construction Pvt Ltd, Mysuru.

Ref No

: --

Project*

: Construction of Commercial building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Roof slab & Beam concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

14/01/16

22/01/16

8.220
8.250
8.285

Failure
Load
(kN)
370
370
400

Compressive
Strength (MPa)
16.44
16.44
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16405

Date: 22/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 21/01/16.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

11/12/15

21/01/16

8.360
8.385
8.390

Failure
Load
(kN)
650
780
490

Compressive
Strength (MPa)
28.89
34.67
21.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16380

Date: 20/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 19/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footings.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
12/01/16

Date of
Testing

Weight
(Kg)

19/01/16

8.820
8.440
8.200

Failure
Load
(kN)
500
535
500

Compressive
Strength (MPa)
22.22
23.78
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16380

Date: 20/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: RR Thulasi Builders (I) Pvt Ltd, Mysore.

Ref No

: Letter dated 19/01/16.

Project*

: KMF Mega Dairy, Alanahalli, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pedestal.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
12/01/16

Date of
Testing

Weight
(Kg)

19/01/16

8.315
8.175
8.100

Failure
Load
(kN)
540
570
530

Compressive
Strength (MPa)
24.00
25.33
23.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16411

Date: 25/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, Zone-2, MUDA, Mysore.

Ref No

: Letter No. MUDA/AEE/Zone-2/2015-16 dated 21/01/16.

Project*

: Construction of gas furnace crematorium and development of


existing grave yard in JCST K block (near Cauvery School),
Kuvempunagr, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm.

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

22/12/15

23/01/16

Weight
(Kg)
7.905
8.110
8.145

Failure Load
(kN)
455
410
500

Compressive
Strength (MPa)
20.22
18.22
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16409

Date: 25/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hi rise Infratech Pvt Ltd, Assam.

Ref No

: --

Project*

: Regional Science Centre, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

15/01/16

23/01/16

7.900
7.845
8.005

500
515
400

22.22
22.89
17.78

Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16415

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 25/01/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

17/01/16

25/01/16

7.950
7.980
8.060

400
625
610

17.78
27.78
27.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16414

Date: 28/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer/Works, SWR, Mysore.

Ref No

: Letter No. 390/SW/MYS/16 dated 20/01/16.

Project*

: Improvements to watering arrangements @ station.


Construction of OHT tank @ Mysor.e

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: RCC Vertical wall of Main tank , top dome and beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

18/01/16

25/01/16

8.010
7.615

Failure
Load
(kN)
580
560

Compressive
Strength (MPa)
25.75
24.89

--

--

--

--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16418

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Uttaradi Mutt , Mysore Branch, Kandayanagar,


Srirampura 2nd Stage, Mysuru.

Ref No

: Letter No 001/2015-16 dated 20/01/2016.

Project*

: Construction of religious complex in RCA Site No. 2A


@ Kandayanagar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
18/01/16

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

25/01/16

8.450
8.325
8.400

Failure
Load
(kN)
700
600
960

Compressive
Strength (MPa)
31.11
26.67
42.67

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16425

Date: 28/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Uttaradi Mutt , Mysore Branch, Kandayanagar,


Srirampura 2nd Stage, Mysuru.

Ref No

: Letter dated 27/01/2016.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/01/16

Date of
Testing

Weight
(Kg)

27/01/16

8.230
8.135
8.170

Failure
Load
(kN)
630
885
680

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
28.00
39.33
30.22

Testing Officer

Head of the Dept

CRC No: 16424

Date: 29/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 27/01/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Second floor North East Roof Slab (Gird 2H to11A)


MSR Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6
7
8
9

----------

Date of
Casting

30/12/15

Date of
Testing

Weight
(Kg)

27/01/16

8.180
8.000
8.210
7.915
8.010
7.900
8.220
8.000
8.075

Failure
Load
(kN)
400
300
600
675
730
720
450
450
620

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
17.78
13.33
26.67
30.00
32.44
32.00
20.00
20.00
27.55

3. Any correction invalidates this report.

1Testing Officer

Head of the Dept

CRC No: 16426

Date: 28/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 27/01/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
18/01/16

Date of
Testing

Weight
(Kg)

27/01/16

8.280
8.245
8.205

Failure
Load
(kN)
500
610
550

Compressive
Strength (MPa)
22.22
27.11
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16426

Date: 28/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 27/01/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
18/01/16

Date of
Testing

Weight
(Kg)

27/01/16

8.200
8.260
8.320

Failure
Load
(kN)
650
430
480

Compressive
Strength (MPa)
28.89
19.11
21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16440

Date: 30/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client
: Assistant Executive Engineer, KUWSA&DB,
Sub division, Mysore.
Ref No

: Letter dated 29/01/16.

Project*

: Construction of Head Works, Providing MS transmission main


and alied works under providing Water Supply scheme to
BARC near Ilwala with Cauvery as source under DC Work.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30, Jack well Raft Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
31/12/15

Date of
Testing

Weight
(Kg)

29/01/16

8.775
8.530
--

Failure
Load
(kN)
805
400
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
35.78
17.78
--

Testing Officer

Head of the Dept

CRC No: 16438

Date: 30/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 29/01/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Entrance Ramp Raft Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

22/01/16

29/01/16

7.855
7.820
8.065

Failure
Load
(kN)
450
470
450

Compressive
Strength (MPa)
20.00
20.89
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16271

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Government Employees House Building Co-operative Society


Ltd., Mysore.

Ref No

: Letter dated 28/12/15.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

----

28/12/15

25/01/16

Weight
(Kg)
8.330
8.325
8.145

Failure Load
(kN)
800
875
800

Compressive
Strength (MPa)
35.55
38.89
35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16417

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: --

Project*

: Cauvery drinking water to Malanayakanahalli and


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Jackwell Ramp.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/12/15

Date of
Testing

Weight
(Kg)

25/01/16

7.815
7.885
7.885

Failure
Load
(kN)
265
280
270

Compressive
Strength (MPa)
11.78
12.44
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16417

Date: 27/01/16
TEST REPORT
ON

Compressive Strength of Concrete Cubes


Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: --

Project*

: Cauvery drinking water to Malanayakanahalli and


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Jackwell 3rd lift.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/12/15

Date of
Testing

Weight
(Kg)

25/01/16

7.840
8.300
7.760

Failure
Load
(kN)
370
400
310

Compressive
Strength (MPa)
16.44
17.78
13.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16417

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: --

Project*

: Cauvery drinking water facilities to Mavathur and


31 other villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: MBR 2

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

4th Brace beam.

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/12/15

25/01/16

7.720
7.515
7.740

Failure
Load
(kN)
310
325
300

Compressive
Strength (MPa)
13.78
14.44
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16417

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: --

Project*

: Cauvery drinking water facilities toMalanayakanahalli and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/12/15

Date of
Testing

Weight
(Kg)

25/01/16

7.920
7.750
7.650

Failure
Load
(kN)
240
490
270

Compressive
Strength (MPa)
10.67
21.78
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16417

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: --

Project*

: Cauvery drinking water facilities to Mavathur and


41 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: MBR 2

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/12/15

5 Brace beam.

Date of
Testing

Weight
(Kg)

25/01/16

7.620
7.970
7.810

Failure
Load
(kN)
335
365
300

Compressive
Strength (MPa)
14.89
16.22
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16417

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: --

Project*

: Cauvery drinking water facilities to Mavathur and


other 32 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: MBR 2

6 Brace beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

14/01/16

25/01/16

8.115
7.735
7.980

Failure
Load
(kN)
250
275
270

Compressive
Strength (MPa)
11.11
12.22
12.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16417

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: --

Project*

: Cauvery drinking water to Malanayakanahalli and


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Jackwell 4th lift.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

26/12/15

25/01/16

8.025
7.995
7.875

Failure
Load
(kN)
470
420
415

Compressive
Strength (MPa)
20.89
18.67
18.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16417

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: --

Project*

: Cauvery drinking water for Malanayakanahalli and


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Jackwell 2nd lift.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/12/15

25/01/16

7.750
8.240
7.960

Failure
Load
(kN)
230
200
230

Compressive
Strength (MPa)
10.22
8.89
10.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16417

Date: 27/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: --

Project*

: Cauvery drinking water for Malanayakanahalli and


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: Jackwell first lift.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

19/12/15

25/01/16

8.130
8.260
8.060

715
530
450

31.78
23.55
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16436

Date: 29/01/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Simplex Infrastructures Limited, Hulikeraa, Mandya.

Ref No

: Letter No. Simplex/NIE/C2957/PM/168 dated 28/01/2016.

Project*

: Zuari Garden City Project.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of
Casting

Date of
Testing

Weight
(Kg)

28/12/15

28/01/16

7.810
8.115

Failure
Load
(kN)
900
855

Compressive
Strength (MPa)
40.00
38.00

--

8.190

870

38.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16449

Date: 02/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 01/02/16.

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/01/16

1.* Information furnished by the client.

Date of
Testing

Weight
(Kg)

01/02/16

8.060
8.330
8.200

Failure
Load
(kN)
250
320
250

Compressive
Strength (MPa)
11.11
14.22
11.11

2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16392

Date: 01/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Uttaradi Mutt , Mysore Branch, Kandayanagar,


Srirampura 2nd Stage, Mysuru.

Ref No

: Letter No. 001/2015-16dated 20/01/2016.

Project*

: Construction of religious complex in R C.A. Site NO. 2A


at Kandaya Nagar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

13/01/16

20/01/16

8.450
8.250
8.270

Failure
Load
(kN)
620
785
600

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
27.55
34.89
26.67

Testing Officer

Head of the Dept

CRC No: 16455

Date: 03/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KHB, Kenchalagudu, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 02/02/16.

Project*

: Construction of at Kenchalagudu, Mysore under the


KHB Department.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Box drain raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/01/16

Date of
Testing

Weight
(Kg)

02/02/16

7.860
7.650
7.465

Failure
Load
(kN)
130
120
120

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
5.78
5.33
5.33

Testing Officer

Head of the Dept

CRC No: 16455

Date: 03/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KHB, Kenchalagudu, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 02/02/16.

Project*

: Construction of at Kenchalagudu, Mysore under the


KHB Department.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, trapizodal raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/01/16

Date of
Testing

Weight
(Kg)

02/02/16

7.7895
7.870
8.000

Failure
Load
(kN)
515
350
470

Compressive
Strength (MPa)
22.89
15.55
20.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16471

Date: 05/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Uttaradi Mutt , Mysore Branch, Kandayanagar,


Srirampura 2nd Stage, Mysuru.

Ref No

: Letter dated 27/01/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
28/01/16

Date of
Testing

Weight
(Kg)

04/02/16

8.250
8.180
8.260

Failure
Load
(kN)
750
750
750

Compressive
Strength (MPa)
33.33
33.33
33.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16469

Date: 05/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SNR Associates, Mysore.

Ref No

: Letter dated 04/02/16

Project*

: Construction of Museum at Suttur.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, GF Roof slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/01/16

04/02/16

7.940
7.900
7.890

Failure
Load
(kN)
290
430
460

Compressive
Strength (MPa)
12.89
19.11
20.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16474

Date: 05/02/16
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: KNK Nexgen Construction (P) Ltd, KSPHC, Mysuru.

Ref No

: Letter dated 04/02/16.

Project*

: Construction of indoor stadium at U.A.C. @ KPC.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

04/01/16

Date of
Testing

Weight
(Kg)

04/02/16

8.090
8.340
8.015
8.270
7.905
7.900

Failure
Load
(kN)
590
970
700
770
745
700

Compressive
Strength (MPa)
26.22
43.11
31.11
34.22
33.11
31.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16474

Date: 05/02/16

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: KNK Nexgen Construction (P) Ltd, KSPHC, Mysuru.

Ref No

: Letter dated 04/02/16.

Project*

: Construction of indoor stadium at U.A.C. @ KPC.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

-------

Date of
Casting

07/01/16

Date of
Testing

Weight
(Kg)

04/02/16

8.300
8.235
8.195
8.220
8.250
8.210

Failure
Load
(kN)
800
790
800
600
750
800

Compressive
Strength (MPa)
35.55
35.11
35.55
26.67
33.33
35.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16485

Date: 08/02/16
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: Shri Vishnu Constructions, Mysore.

Ref No

: Letter dated 06/02/16.

Project*

: Farm House Jodupala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25..

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/01/16

Date of
Testing

Weight
(Kg)

06/02/16

7.860
8.000
7.935

Failure
Load
(kN)
515
525
530

Compressive
Strength (MPa)
22.89
23.33
23.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16482

Date: 08/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri Bindumadhava Religious Trust, Belaguru, Hosadurga Tq.

Ref No

: Letter dated 06/02/16.

Project*

: Sabha Bhavana.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 2nd floor roof slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/01/16

06/02/16

7.645
8.090
7.900

Failure
Load
(kN)
420
300
350

Compressive
Strength (MPa)
18.67
13.33
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16461

Date: 04/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Director, KMF, Bangalore.

Ref No

: Your letter dated 03/02/16.

Project*

: Construction of Building & other related works for


establishment of New Dairy at Kuderu village,
Santhemarahalli Hobli, Chamarajanagar District for
Mysore Milk Union.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pedestal.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/12/15

03/02/16

7.755
7.800
7.905

Failure
Load
(kN)
680
680
670

Compressive
Strength (MPa)
30.22
30.22
29.77

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16461

Date: 04/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Director, KMF, Bangalore.

Ref No

: Your letter dated 03/02/16.

Project*

: Construction of Building & other related works for


establishment of New Dairy at Kuderu village,

Santhemarahalli Hobli, Chamarajanagar District for


Mysore Milk Union.
Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

17/12/15

03/02/16

7.903
8.000
7.965

Failure
Load
(kN)
700
690
680

Compressive
Strength (MPa)
31.11
30.67
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16461

Date: 04/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Director, KMF, Bangalore.

Ref No

: Your letter dated 03/02/16.

Project*

: Construction of Building & other related works for


establishment of New Dairy at Kuderu village,
Santhemarahalli Hobli, Chamarajanagar District for
Mysore Milk Union.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
24/11/15

Date of
Testing

Weight
(Kg)

03/02/16

7.855
7.900
7.985

Failure
Load
(kN)
560
550
550

Compressive
Strength (MPa)
24.89
24.44
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16489

Date: 09/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 08/02/16.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, UG Sump slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
10/01/16

Date of
Testing

Weight
(Kg)

08/02/16

7.910
7.810
7.670

Failure
Load
(kN)
430
610
400

Compressive
Strength (MPa)
19.11
27.11
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16489

Date: 09/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Tapovan Engineering, Mysore.

Ref No

: Letter dated 08/02/16.

Project*

: SDM College, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, UG Sump wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/01/16

08/02/16

8.450
7.565
7.430

Failure
Load
(kN)
880
425
400

Compressive
Strength (MPa)
39.11
18.89
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16487

Date: 09/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Annapoorna Constructions, Bangalore (NIE IT).

Ref No

: Letter dated 08/02/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Tie beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

30/01/16

08/02/16

7.780
7.910
7.715

Failure
Load
(kN)
290
300
300

Compressive
Strength (MPa)
12.89
13.33
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16504

Date: 11/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Nanjundaswamy, Contractor, Chamarajanagar.

Ref No

: Letter dated 10/02/16.

Project*

: Construction of Godown and dormitory building


@ JSS, Suttur.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Tie beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

30/01/16

08/02/16

7.780
7.910
7.715

290
300
300

12.89
13.33
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16505

Date: 12/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AV Constructions, (AVC/NC).

Ref No

: Letter dated 11/02/16.

Project*

: Construction of Neuro Care Centre @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RMC (Lafarge)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

--

13/01/16

11/02/16

8.225

Failure
Load
(kN)
560

Compressive
Strength (MPa)
24.89

2
3

---

8.200
8.205

500
530

22.22
23.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 15725

Date: 17/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 15/02/16.

Project*

: Subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/02/16

15/02/16

8.185
8.190
--

Failure
Load
(kN)
850
935
--

Compressive
Strength (MPa)
37.78
41.55
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 15726

Date: 17/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 15/02/16.

Project*

: Subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/02/16

Date of
Testing

Weight
(Kg)

15/02/16

8.215
8.200
--

Failure
Load
(kN)
800
750
--

Compressive
Strength (MPa)
35.55
33.33
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16535

Date: 17/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 16/02/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of *
Casting
17/01/16

Date of
Testing

Weight
(Kg)

16/02/16

8.105
8.130
8.050

Failure
Load
(kN)
610
1050
860

Compressive
Strength (MPa)
27.11
46.67
38.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16539

Date: 18/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 17/02/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

18/01/16

17/02/16

8.235
8.080
8.185

Failure
Load
(kN)
550
970
740

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
24.44
43.11
32.89

3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16539

Date: 18/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 17/02/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M30.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
18/01/16

Date of
Testing

Weight
(Kg)

17/02/16

8.185
8.320
7.965

Failure
Load
(kN)
1000
700
660

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
44.44
31.11
29.33

Testing Officer

Head of the Dept

CRC No: 16548

Date: 22/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Nagaraju, Vijayanagar 1st Stage, Mysore.

Ref No

: Letter dated 20/02/16.

Project*

: Construction of residential house.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

23/01/16

20/02/16

8.360
8.310
8.600

Failure
Load
(kN)
1100
1050
980

Compressive
Strength (MPa)
48.89
46.67
43.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16553

Date: 22/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, JNNURM, MCC, Mysore.

Ref No

: Letter No. MCC/JNNURM/AEE-4//2015-16 dated 18/02/16.

Project*

: Construction of multi level parking @ Town hall, Mysuru

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Lower Basement Pedastal Raft. Grid No. 19A and 20A.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
12/02/16

Date of
Testing

Weight
(Kg)

20/02/16

7.970
7.905
8.045

Failure
Load
(kN)
350
320
380

Compressive
Strength (MPa)
15.55
14.22
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16568

Date: 26/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SNR Associates, Mysore.

Ref No

: Letter dated 25/02/16

Project*

: Construction of Museum building at Suttur. (JSS MVP).

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, GF Roof slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

28/01/16

25/02/16

7.950
8.145
7.820

Failure
Load
(kN)
505
500
710

Compressive
Strength (MPa)
22.44
22.22
31.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

CRC No: 16567

Head of the Dept

Date: 26/02/16

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 25/02/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Retaining wall Concrete (entry side) East side 2nd lift.
(MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

15/02/16

25/02/16

7.955
8.220
7.960

Failure
Load
(kN)
320
315
430

Compressive
Strength (MPa)
14.22
14.00
19.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16571

Date: 26/02/16
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: Tapovan Projects, Mysore.

Ref No

: Letter dated 25/02/16

Project*

: Tapovan County.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

Date of
Testing

1
-2
-17/02/16
25/02/16
3
-.* Information furnished by the client.

Weight
(Kg)
8.195
8.305
8.355

Failure
Load
(kN)
500
500
500

Compressive
Strength (MPa)
22.22
22.22
22.22

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16582

Date: 29/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Annapoorna Constructions, Bangalore (NIE IT).

Ref No

: Letter dated 27/02/16.

Project*

: NIE IT.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Tie beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

--

27/02/16

7.575
7.730
7.900

Failure
Load
(kN)
390
385
350

Compressive
Strength (MPa)
17.33
17.11
15.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16579

Date: 29/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 27/02/16.

Project*

: Subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/02/16

27/02/16

8.275
8.380
--

Failure
Load
(kN)
660
950
--

Compressive
Strength (MPa)
29.33
42.22
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16580

Date: 29/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sr. K.V. Chinnaiah, Class I Contractor, SWR, Mysore.

Ref No

: Letter dated 27/02/16.

Project*

: Subway.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M35.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/02/16

Date of
Testing

Weight
(Kg)

27/02/16

8.400
8.370
--

Failure
Load
(kN)
640
750
--

Compressive
Strength (MPa)
28.44
33.33
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16565

Date: 27/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Ankanatheshwara Enterprises, Mysore.

Ref No

: Letter dated 24/02/16.

Project*

: JCK Industrial Layout, Metagalli Industrial Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Culvert Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
30/10/15

Date of
Testing

Weight
(Kg)

24/02/16

7.530
7.730
7.520

Failure
Load
(kN)
580
575
560

Compressive
Strength (MPa)
25.78
25.56
24.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16565

Date: 27/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Ankanatheshwara Enterprises, Mysore.

Ref No

: Letter dated 24/02/16.

Project*

: JCK Industrial Layout, Metagalli Industrial Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, Entry Ramp.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

20/11/15

24/02/16

7.375
7.285
7.415

Failure
Load
(kN)
420
450
460

Compressive
Strength (MPa)
18.67
20.00
20.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16565

Date: 27/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Ankanatheshwara Enterprises, Mysore.

Ref No

: Letter dated 24/02/16.

Project*

: JCK Industrial Layout, Metagalli Industrial Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Culvert Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/10/15

Date of
Testing

Weight
(Kg)

24/02/16

7.660
7.595
7.555

Failure
Load
(kN)
650
650
680

Compressive
Strength (MPa)
28.89
28.89
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16565

Date: 27/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Ankanatheshwara Enterprises, Mysore.

Ref No

: Letter dated 24/02/16.

Project*

: JCK Industrial Layout, Metagalli Industrial Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Culvert Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

07/10/15

24/02/16

7.560
7.370
7.605

Failure
Load
(kN)
680
680
680

Compressive
Strength (MPa)
30.22
30.22
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16565

Date: 27/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Ankanatheshwara Enterprises, Mysore.

Ref No

: Letter dated 24/02/16.

Project*

: JCK Industrial Layout, Metagalli Industrial Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Culvert Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/09/15

Date of
Testing

Weight
(Kg)

24/02/16

7.505
7.700
7.750

Failure
Load
(kN)
700
680
435

Compressive
Strength (MPa)
31.11
30.22
30.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16565

Date: 27/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Ankanatheshwara Enterprises, Mysore.

Ref No

: Letter dated 24/02/16.

Project*

: JCK Industrial Layout, Metagalli Industrial Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, Wall Around Tree.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

09/12/15

24/02/16

7.490
7.905
7.425

Failure
Load
(kN)
435
410
450

Compressive
Strength (MPa)
19.33
18.22
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16565

Date: 27/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Ankanatheshwara Enterprises, Mysore.

Ref No

: Letter dated 24/02/16.

Project*

: JCK Industrial Layout, Metagalli Industrial Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Culvert Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
07/10/15

Date of
Testing

Weight
(Kg)

24/02/16

7.780
7.650
7.515

Failure
Load
(kN)
550
560
550

Compressive
Strength (MPa)
24.44
24.89
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16565

Date: 27/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Ankanatheshwara Enterprises, Mysore.

Ref No

: Letter dated 24/02/16.

Project*

: JCK Industrial Layout, Metagalli Industrial Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Culvert Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
04/10/15

Date of
Testing

Weight
(Kg)

24/02/16

7.560
7.685
7.490

Failure
Load
(kN)
600
580
585

Compressive
Strength (MPa)
26.67
25.78
26.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16565

Date: 27/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Ankanatheshwara Enterprises, Mysore.

Ref No

: Letter dated 24/02/16.

Project*

: JCK Industrial Layout, Metagalli Industrial Layout, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M15, Entry Ramp.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
16/11/15

Date of
Testing

Weight
(Kg)

24/02/16

7.810
7.860
7.665

Failure
Load
(kN)
480
450
480

Compressive
Strength (MPa)
21.33
20.00
21.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16594

Date: 03/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: SSE, Works, South Western Railway, Mysore.

Ref No

: Letter No. 391/SW/MYS/16 dated 02/03/16.

Project*

: Construction of mobilization hall (35 beds) for RPF Staff.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4
5
6

----

Date of
Casting

25/02/16

Date of
Testing

Weight
(Kg)

03/03/16

8.080
8.185
8.185
8.220
8.285
8.300

Failure
Load
(kN)
360
420
350
345
385
360

Compressive
Strength (MPa)
16.00
18.67
15.56
15.33
17.11
16.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16588

Date: 03/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Giddegowda, Contractor, Bengaluru.

Ref No

: Letter dated 01/03/16.

Project*

: PTU & UGD, Nanjangud.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

:1:2:4

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/02/16

Date of
Testing

Weight
(Kg)

01/03/16

8.130
8.155
8.120

Failure
Load
(kN)
300
310
300

Compressive
Strength (MPa)
13.33
13.78
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16590

Date: 03/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Bengaluru.

Ref No

: Letter dated 02/03/16.

Project*

: JSS Layout Varuna Arch Beam concrete.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 1:1 : 3

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
19/02/16

Date of
Testing

Weight
(Kg)

02/03/16

8.250
8.430
8.305

Failure
Load
(kN)
600
790
630

Compressive
Strength (MPa)
26.67
35.11
28.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16590

Date: 03/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Bengaluru.

Ref No

: Letter dated 02/03/16.

Project*

: JSS Layout Varuna Culvert Concrete.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 1:1 : 3

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
23/01/16

Date of
Testing

Weight
(Kg)

02/03/16

7.690
7.795
7.975

Failure
Load
(kN)
600
450
400

Compressive
Strength (MPa)
26.67
20.00
17.75

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16585

Date: 03/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 01/03/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Compound Wall Putting. (MSR Concrete)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

21/02/16

01/03/16

7.530
8.155
7.800

Failure
Load
(kN)
490
500
505

Compressive
Strength (MPa)
21.78
22.22
22.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16602

Date: 08/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 04/03/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Second Floor South West Roof Slab (13 0 to 25 H)


MSR Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
27/02/16

Date of
Testing

Weight
(Kg)

04/03/16

7.990
8.025
8.020

Failure
Load
(kN)
300
315
300

Compressive
Strength (MPa)
13.33
14.00
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16595

Date: 04/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: ESS & ESS Infrastructures Pvt Limited, Bengaluru.

Ref No

: Letter dated 02/03/16.

Project*

: JSS Layout Arch Bhim Concrete, Varuna.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3

----

: 150 mm x 150 mm x 150 mm


Date of
Casting
23/01/16

Date of
Testing

Weight
(Kg)

02/03/16

8.535
8.335
8.270

Failure
Load
(kN)
595
750
500

Compressive
Strength (MPa)
26.44
33.33
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16597

Date: 05/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Uttaradi Mutt , Mysore Branch, Kandayanagar,


Srirampura 2nd Stage, Mysuru.

Ref No

: Letter dated 03/03/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

25/02/16

03/03/16

8.150
8.190
8.180

Failure
Load
(kN)
450
550
450

Compressive
Strength (MPa)
20.00
24.44
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16603

Date: 08/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Preethi International Pvt Ltd, Mysuru.

Ref No

: Letter dated 04/03/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

27/02/16

04/03/16

8.465
8.250
8.290

Failure
Load
(kN)
510
400
420

Compressive
Strength (MPa)
22.67
17.78
18.67

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16621

Date: 10/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 09/03/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

28/02/16

09/03/16

8.120
8.150
8.225

550
645
540

24.44
28.67
24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16609

Date: 10/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. ATC Telecom Tower Corporation Pvt Ltd, Gargaon.

Ref No

: Letter dated 08/03/16.

Project*

: Construction of telecom tower at New Tilak Nagar,


Mysore-KA/MY/A1/12118

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Beams.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

01/03/16

08/03/16

7.845
8.205
7.685

550
605
400

24.44
26.89
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16614

Date: 10/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: R. Ajith, Chamundipuram, Mysore.

Ref No

: Letter dated 08/03/16.

Project*

: Commercial Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

1
2
3

----

07/02/16

08/03/16

8.030
7.950
8.010

Failure
Load
(kN)
410
390
400

Compressive
Strength (MPa)
18.22
17.33
17.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16612

Date: 10/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri Bindumadhava Religious Trust, Belaguru, Hosadurga Tq.

Ref No

: Letter dated 08/03/16.

Project*

: Sabha Bhavana.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: 3rd Floor roof (Dome Slab)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

21/02/16

08/03/16

7.750
7.860
7.640

Failure
Load
(kN)
350
400
300

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
15.55
17.78
13.33

3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16610

Date: 10/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, Sri Chamarajendra Zoological


Garden, Mysuru.

Ref No

: Letter No. MZA/AEE/1266/2015-16 dated 05/03/16.

Project*

: Construction of Amphitheater inside zoo gardens

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Entry Slab No. 1.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

01/03/16

08/03/16

8.300
8.345
--

Failure
Load
(kN)
470
600
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.89
26.67
--

Testing Officer

Head of the Dept

CRC No: 16610

Date: 10/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, Sri Chamarajendra Zoological


Garden, Mysuru.

Ref No

: Letter No. MZA/AEE/1266/2015-16 dated 05/03/16.

Project*

: Construction of Amphitheater inside zoo gardens

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Entry Slab No. 2.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

02/03/16

09/03/16

8.350
8.335
--

Failure
Load
(kN)
470
470
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.89
20.89
--

Testing Officer

Head of the Dept

CRC No: 16624

Date: 11/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Uttaradi Mutt , Mysore Branch, Kandayanagar,


Srirampura 2nd Stage, Mysuru.

Ref No

: Letter dated 10/03/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
25/02/16

Date of
Testing

Weight
(Kg)

10/03/16

8.060
8.050
8.190

Failure
Load
(kN)
600
800
520

Compressive
Strength (MPa)
26.67
35.55
23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16627

Date: 11/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Hotel Preethi International Pvt Ltd, Mysuru.

Ref No

: --

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
03/03/16

Date of
Testing

Weight
(Kg)

10/03/16

8.075
7.945
8.100

Failure
Load
(kN)
510
570
450

Compressive
Strength (MPa)
22.67
25.33
20.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16628

Date: 12/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Principal Government College, Mandya.

Ref No

: Your letter dated 05/03/16

Project*

: Indoor Stadium Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/11/15

Date of
Testing

Weight
(Kg)

10/03/16

8.100
7.990
8.000

Failure
Load
(kN)
540
580
540

Compressive
Strength (MPa)
24.00
25.78
24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16628

Date: 12/03/16
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: Principal Government College, Mandya.

Ref No

: Your letter dated 05/03/16

Project*

: Indoor Stadium Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Roof.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/11/15

Date of
Testing

Weight
(Kg)

10/03/16

8.050
8.050
8.070

Failure
Load
(kN)
520
560
550

Compressive
Strength (MPa)
23.11
24.89
24.44

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16628

Date: 12/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Principal Government College, Mandya.

Ref No

: Your letter dated 05/03/16

Project*

: Indoor Stadium Building.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Gutter Beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
20/02/16

Date of
Testing

Weight
(Kg)

10/03/16

8.120
8.110
8.000

Failure
Load
(kN)
650
660
670

Compressive
Strength (MPa)
28.89
29.33
29.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16623

Date: 15/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KRIDL, Chamarajanagara.

Ref No

: Your letter No. AEE/KRIDL/Ch.Nagar/CCubes/2015-16/


735 dated 09/03/16.

Project*

: ZP Resource Centre Building (DPRC), Chamarajanagar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, 2nd floor roof concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
600
680
600

1
3
7.625
2
3
16/12/15
09/03/16
7.960
3
3
7.900
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
26.67
30.22
26.67

Testing Officer

Head of the Dept

CRC No: 16623

Date: 15/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KRIDL, Chamarajanagara.

Ref No

: Your letter No. AEE/KRIDL/Ch.Nagar/CCubes/2015-16/


735 dated 09/03/16.

Project*

: Construction of 2 No.s class room & Toilet Building of Govt


Pre University College, Santhe Maralli Grama,

Chamarajanagar Taluk.
Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Footing Concrete..

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
460
480
460

1
1
8.230
2
1
10/02/16
09/03/16
8.140
3
1
8.100
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
20.44
21.33
20.44

Testing Officer

Head of the Dept

CRC No: 16623

Date: 15/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KRIDL, Chamarajanagara.

Ref No

: Your letter No. AEE/KRIDL/Ch.Nagar/CCubes/2015-16/


735 dated 09/03/16.

Project*

: Construction of Dining Hall & office Complex to New Saba


Bhavana GF @ ZP, Chamarajanagar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Footing Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)
610
620
610

1
2
7.945
2
2
09/02/16
09/03/16
8.400
3
2
8.080
Note:
1.* Information furnished by the client.
2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
27.11
27.56
27.11

Testing Officer

Head of the Dept

CRC No: 16455

Date: 03/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, Karnataka Housing Board, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 15/03/16.

Project*

: Construction work at Kenchalagudu, Mysore under the


KHB Department.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Trapizoidal wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

----

08/03/16

15/03/16

7.635
7.815
--

Failure
Load
(kN)
415
560
--

Compressive
Strength (MPa)
18.44
24.89
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16455

Date: 03/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, Karnataka Housing Board, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 15/03/16.

Project*

: Construction work at Kenchalagudu, Mysore under the


KHB Department.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Trapizoidal Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

1
2
3

----

: 150 mm x 150 mm x 150 mm


Date of*
Casting
09/03/16

Date of
Testing

Weight
(Kg)

15/03/16

7.875
7.985
--

Failure
Load
(kN)
430
470
--

Compressive
Strength (MPa)
19.11
20.89
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16455

Date: 03/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, Karnataka Housing Board, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 15/03/16.

Project*

: Construction work at Kenchalagudu, Mysore under the


KHB Department.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Dox drain Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

----

17/02/16

15/03/16

7.775
7.845
--

Failure
Load
(kN)
200
380
--

Compressive
Strength (MPa)
8.89
16.89
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16455

Date: 03/02/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, Karnataka Housing Board, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 15/03/16.

Project*

: Construction work at Kenchalagudu, Mysore under the


KHB Department.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Box drain Raft.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
2
3

----

17/02/16

7.880
7.865
--

15/03/16

600
700
--

26.67
31.11
--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16654

Date: 18/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, Karnataka Housing Board, Mysuru.


Deviprasad Constructions Pvt Ltd, Kaup, Udupi.

Ref No

: Letter dated 17/03/16.

Project*

: Construction work at Kenchalagudu, Mysore under the


KHB Department.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Culvert Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
2
3

----

09/03/16

17/03/16

7.860
8.105
7.960

400
510
380

17.78
22.67
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16654

Date: 18/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, Karnataka Housing Board, Mysuru.


Deviprasad Constructions Pvt Ltd, Kaup, Udupi.

Ref No

: Letter dated 17/03/16.

Project*

: Construction work at Kenchalagudu, Mysore under the


KHB Department.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Trapezoidal Drain.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of*
Casting

Date of
Testing

Weight
(Kg)

20/02/16

17/03/16

7.935
7.840

Failure
Load
(kN)
500
660

Compressive
Strength (MPa)
22.22
29.33

--

--

--

--

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16653

Date: 18/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. ATC Telecom Tower Corporation Pvt Ltd, Gargaon.

Ref No

: Letter dated 08/03/16.

Project*

: Construction of telecom tower at Lakshmikanth Nagar,


Hebbal, Mysore-KA/MA/A1/12119.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20 Beams.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of*
Casting
18/02/16

Date of
Testing

Weight
(Kg)

17/03/16

8.150
8.070
8.110

Failure
Load
(kN)
950
750
680

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
42.22
33.33
30.22

Testing Officer

Head of the Dept

CRC No: 16648

Date: 18/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 16/03/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Entry Ramp Back Side Second Lift (East Side)


MSR Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
18/02/16

Date of
Testing

Weight
(Kg)

16/03/16

7.910
7.830
8.110

Failure
Load
(kN)
700
770
750

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Compressive
Strength (MPa)
31.11
34.22
33.33

Testing Officer

Head of the Dept

CRC No: 16659

Date: 21/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Shri Vishnu Constructions, Mysore.

Ref No

: Letter dated 18/03/16.

Project*

: Farm House Jodupala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/03/16

18/03/16

8.000
8.500
8.295

Failure
Load
(kN)
990
750
980

Compressive
Strength (MPa)
44.00
33.33
43.55

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16660

Date: 21/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Amarnath, No. D7, Paramahamsa Road, Mysore.

Ref No

: Letter dated 18/03/16.

Project*

: Residence.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
05/03/16

Date of
Testing

Weight
(Kg)

18/03/16

8.135
8.185
8.245

Failure
Load
(kN)
460
545
410

Compressive
Strength (MPa)
20.44
24.22
18.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16662

Date: 22/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AV Constructions, (AVC/NC).

Ref No

: Letter dated 21/03/16.

Project*

: Construction of Neuro Care Centre @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, RMC (Lafarge)

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
06/03/16

Date of
Testing

Weight
(Kg)

21/03/16

8.375
8.245
8.250

Failure
Load
(kN)
590
450
610

Compressive
Strength (MPa)
26.22
20.00
27.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16663

Date: 22/03/16

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: AEE, NH Sub Division, Mysore-05.

Ref No

: Letter No. AEE/NHSD/QC Test/Way Side Amenities/


15-16/915 dated 16/03/2015.

Project*

: Third party quality control test for the work of providing


protection and way side amenities to Kabini Bridge Near
T.Narasipura @ Ch 240 -450 on NH 212 KK Section.
(Job No. NH-212-KNT-2015-16-757)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

05/02/16

21/03/16

7.645
7.755
7.435

Failure
Load
(kN)
580
570
570

Compressive
Strength (MPa)
25.78
25.33
25.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16663

Date: 22/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, NH Sub Division, Mysore-05.

Ref No

: Letter No. AEE/NHSD/QC Test/Way Side Amenities/


15-16/915 dated 16/03/2015.

Project*

: Third party quality control test for the work of providing


protection and way side amenities to Kabini Bridge Near
T.Narasipura @ Ch 240 -450 on NH 212 KK Section.
(Job No. NH-212-KNT-2015-16-757)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
12/02/16

Date of
Testing

Weight
(Kg)

21/03/16

8.195
8.380
8.385

Failure
Load
(kN)
530
530
520

Compressive
Strength (MPa)
23.55
23.55
23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16663

Date: 22/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, NH Sub Division, Mysore-05.

Ref No

: Letter No. AEE/NHSD/QC Test/Way Side Amenities/


15-16/915 dated 16/03/2015.

Project*

: Third party quality control test for the work of providing


protection and way side amenities to Kabini Bridge Near
T.Narasipura @ Ch 240 -450 on NH 212 KK Section.
(Job No. NH-212-KNT-2015-16-757)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
02/02/16

Date of
Testing

Weight
(Kg)

21/03/16

8.200
8.095
8.275

Failure
Load
(kN)
565
580
540

Compressive
Strength (MPa)
25.11
25.78
24.00

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16663

Date: 22/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, NH Sub Division, Mysore-05.

Ref No

: Letter No. AEE/NHSD/QC Test/Way Side Amenities/


15-16/915 dated 16/03/2015.

Project*

: Third party quality control test for the work of providing


protection and way side amenities to Kabini Bridge Near
T.Narasipura @ Ch 240 -450 on NH 212 KK Section.
(Job No. NH-212-KNT-2015-16-757)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

03/02/16

21/03/16

7.465
7.570
7.720

Failure
Load
(kN)
520
530
520

Compressive
Strength (MPa)
23.11
23.55
23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16672

Date: 24/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KHB&Sub division, Mysore.

Ref No

: Letter dated 22/03/2016

Project*

: Proposed Regional Transport Office in Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Dome concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Agency

: M/s Gadhiraju Constructions pvt ltd, Bangalore.

Sl
No

ID No.

1
2
3

----

Date of
Casting
15/03/16

Date of
Testing

Weight
(Kg)

22/03/16

7.780
7.435
7.625

Failure
Load
(kN)
385
390
390

Compressive
Strength (MPa)
17.11
17.33
17.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16689

Date: 28/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 26/03/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Second floor roof slab (South West) 13 0 to 24H


MSR Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

27/02/16

26/03/16

8.160
8.120
8.030

Failure
Load
(kN)
800
795
740

Compressive
Strength (MPa)
35.55
35.33
32.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16689

Date: 28/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Ramalingam Construction Company Pvt Ltd, Mysore.

Ref No

: Letter dated 26/03/16.

Project*

: Construction of Dr. B.R. Ambedkar Bhavan @ Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Second floor roof slab (South West) 13 0 to 24H


MSR Concrete.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No
1
2
3

: 150 mm x 150 mm x 150 mm

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

27/02/16

26/03/16

7.920
8.215
8.050

Failure
Load
(kN)
600
615
610

Compressive
Strength (MPa)
26.67
27.33
27.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16693

Date: 29/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, JNNURM, MCC, Mysore.

Ref No

: Letter No. MCC/JNNURM/AEE-4//2015-16 dated 28/03/16.

Project*

: Construction of multi level parking @ Town hall, Mysuru

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Grid No. 18&19 Upper basemen Roof slab and beam.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

22/03/16

28/03/16

8.060
7.830
7.945

Failure
Load
(kN)
350
290
300

Compressive
Strength (MPa)
15.55
12.89
13.33

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16695

Date: 29/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. ATC Telecom Tower Corporation Pvt Ltd, Gurgaon.

Ref No

: Letter dated 29/03/16.

Project*

: Construction of telecom tower at New Tilak Nagar,


Mysore-KA/MA/A1/12118.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20 Beams.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

----

01/03/16

29/03/16

7.810
8.140
8.050

Failure
Load
(kN)
680
710
760

Compressive
Strength (MPa)
30.22
31.55
33.78

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16690

Date: 28/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, Sri Chamarajendra Zoological


Garden, Mysuru.

Ref No

: Letter No. MZA/AEE/1355/2015-16 dated 24/03/16.

Project*

: Construction of Amphitheater inside zoo gardens

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Entry Slab No. 2.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
-2
-02/03/16
3
-4
-* Information furnished by the client.

28/03/16

8.325
8.360
8.175
8.375

630
815
750
700

28.00
36.22
33.33
31.11

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16690

Date: 28/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Assistant Executive Engineer, Sri Chamarajendra Zoological


Garden, Mysuru.

Ref No

: Letter No. MZA/AEE/1355/2015-16 dated 24/03/16.

Project*

: Construction of Amphitheater inside zoo gardens

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Entry Slab No. 1.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3
4

-----

Date of*
Casting
01/03/16

Date of
Testing

Weight
(Kg)

28/03/16

8.170
8.340
8.440
8.210

Failure
Load
(kN)
650
900
800
900

Compressive
Strength (MPa)
28.89
40.00
35.55
40.00

* Information furnished by the client.


Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16691

Date: 28/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 26/03/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-28/02/16
26/03/16
3
-* Information furnished by the client.

Weight
(Kg)
8.245
8.145
8.175

Failure
Load
(kN)
675
690
750

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Compressive
Strength (MPa)
30.00
30.67
33.33

Testing Officer

Head of the Dept

CRC No: 16691

Date: 28/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 26/03/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-18/03/16
26/03/16
3
-* Information furnished by the client.

Weight
(Kg)
8.050
8.000
8.040

Failure
Load
(kN)
320
525
500

Compressive
Strength (MPa)
14.22
23.33
22.22

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16706

Date: 30/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Nagaraju, Vijayanagar, Mysore.

Ref No

: Letter dated 29/03/16.

Project*

: Construction of Residential House, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-22/03/16
29/03/16
3
-* Information furnished by the client.

Weight
(Kg)
8.455
8.230
8.195

Failure
Load
(kN)
550
940
860

Compressive
Strength (MPa)
24.44
41.78
38.22

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16635

Date: 28/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Senior Section Engineer/Works, sWR, Mysuru.

Ref No

: Letter No. 6/SW/16 dated 05/03/2016.

Project*

: Construction of 7.5 lakhs liters capacity GLR. RCC work for


raft for construction of GLR 7.5 lakhs liters capacity at
Mysuru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-27/02/16
26/03/16
3
-* Information furnished by the client.

Weight
(Kg)
8.250
8.200
8.225

Failure
Load
(kN)
680
680
670

Compressive
Strength (MPa)
30.22
30.22
29.78

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16710

Date: 31/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri Bindumadhava Religious Trust, Belaguru, Hosadurga Tq.

Ref No

: Letter dated 30/03/16.

Project*

: Sabha Bhavana, Belaguru.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: --

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-23/02/16
30/03/16
3
-* Information furnished by the client.

Weight
(Kg)
7.890
7.615
8.825

Failure
Load
(kN)
490
580
430

Compressive
Strength (MPa)
21.78
25.78
19.11

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16709

Date: 31/03/16

TEST REPORT
ON
Compressive Strength of Concrete Cubes
Client

: AEE, KHB, Kenchalagudu, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 29/03/16.

Project*

: Project work at Kenchalagudu, Jayapura Hobli,


Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Trapizoidal drain wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
01/03/16

Date of
Testing

Weight
(Kg)

29/03/16

8.040
7.785
8.200

Failure
Load
(kN)
450
520
500

Compressive
Strength (MPa)
20.00
23.11
22.22

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16709

Date: 31/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KHB, Kenchalagudu, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 29/03/16.

Project*

: Project work at Kenchalagudu, Jayapura Hobli,


Mysore District.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Box drain wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
22/03/16

Date of
Testing

Weight
(Kg)

29/03/16

7.630
7.795
7.775

Failure
Load
(kN)
300
420
380

Compressive
Strength (MPa)
13.33
18.67
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16712

Date: 30/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: District Supply and Marketing Co-operative Society Ltd,


Bangalore Urban.

Ref No

: Letter No. D.S.M.S.B (U)/dated 28/03/16.

Project*

: Construction of Toilet Block in Crescent Barrac premises


5th Batalion KPA Mysore under DC Work Scheme (Call-2)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-3
-21/03/16
28/03/16
4
-5
-6
-* Information furnished by the client.

Weight
(Kg)
8.215
8.230
8.170
8.210
8.125
8.275

Failure
Load
(kN)
390
410
425
415
420
390

Compressive
Strength (MPa)
17.33
18.22
18.89
18.44
18.67
17.33

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16712

Date: 30/03/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: District Supply and Marketing Co-operative Society Ltd,


Bangalore Urban.

Ref No

: Letter No. D.S.M.S.B (U)/dated 28/03/16.

Project*

: Construction of Toilet Block in Crescent Barrac premises


5th Batalion KPA Mysore under DC Work Scheme (Call-2)

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-3
-21/03/16
28/03/16
4
-5
-6
-* Information furnished by the client.

Weight
(Kg)
8.190
8.200
8.170
8.130
8.045
8.075

Failure
Load
(kN)
415
410
400
395
420
400

Compressive
Strength (MPa)
18.44
18.22
17.78
17.55
18.67
17.78

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16718

Date: 01/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Vastava Constructions, Chamundipuram, Mysuru.

Ref No

: Letter dated 31/03/16.

Project*

: Site No. 1117, F-25, 1117/1, F 25/1, JLB road, Fort Mohalla,
Chamundipuram, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Pillar Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-24/03/16
31/03/16
3
-* Information furnished by the client.

Weight
(Kg)
7.750
7.820
7.690

Failure
Load
(kN)
350
335
320

Compressive
Strength (MPa)
15.55
14.89
14.22

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16719

Date: 01/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: -Nil-

Project*

: Water supply system to Mallanayakanahalli and other


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pump House 2 Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

1
-2
-12/03/16
3
-* Information furnished by the client.

Date of
Testing

Weight
(Kg)

31/03/16

8.100
8.065
8.160

Failure
Load
(kN)
210
190
180

Compressive
Strength (MPa)
9.33
8.44
8.00

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16719

Date: 01/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: -Nil-

Project*

: Water supply system to Mallanayakanahalli and other


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Jackwell Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

1
-2
-24/02/16
3
-* Information furnished by the client.

Date of
Testing

Weight
(Kg)

31/03/16

7.815
7.500
7.610

Failure
Load
(kN)
300
285
220

Compressive
Strength (MPa)
13.33
12.67
9.78

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16719

Date: 01/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: -Nil-

Project*

: Water supply system to Mallanayakanahalli and other


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pump House 1 Roof Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

: 150 mm x 150 mm x 150 mm


Date of*
Casting

1
-2
-29/02/16
3
-* Information furnished by the client.

Date of
Testing

Weight
(Kg)

31/03/16

7.675
7.640
7.700

Failure
Load
(kN)
410
425
330

Compressive
Strength (MPa)
18.22
18.89
14.67

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16719

Date: 01/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: -Nil-

Project*

: Water supply system to Mavathur and other 31 villages


In K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 2 Side wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

1
-2
-24/02/16
3
-* Information furnished by the client.

Date of
Testing

Weight
(Kg)

31/03/16

7.790
7.860
8.190

Failure
Load
(kN)
295
230
315

Compressive
Strength (MPa)
13.11
10.22
14.00

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16719

Date: 01/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: -Nil-

Project*

: Water supply system to Mallanayakanahalli and other


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Quarters Roof slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

Failure
Load

Compressive
Strength (MPa)

(kN)
1
-2
-05/03/16
3
-* Information furnished by the client.

31/03/16

7.635
7.960
8.120

250
325
320

11.11
14.44
14.22

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16719

Date: 01/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: -Nil-

Project*

: Water supply system to Mallanayakanahalli and other


42 villages of K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pump House 1 Lintel Chejja.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

Failure
Load
(kN)

Compressive
Strength (MPa)

1
-2
-05/03/16
3
-* Information furnished by the client.

31/03/16

7.135
8.135
8.215

390
250
400

17.33
11.11
17.78

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16719

Date: 01/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: M/s. Maloo Constructions (India) Pvt Ltd, Bangalore.

Ref No

: -Nil-

Project*

: Water supply system to Mavathur and other 31 villages


In K.R. Nagar Taluk, Mysore district.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, MBR 2 Columns.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2

---

Date of*
Casting

Date of
Testing

Weight
(Kg)

29/02/16

31/03/16

7.625
7.875

Failure
Load
(kN)
440
510

Compressive
Strength (MPa)
19.55
22.67

3
-* Information furnished by the client.

7.615

350

15.55

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16736

Date: 06/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Shri Vishnu Constructions, Mysore.

Ref No

: Letter dated 04/04/16.

Project*

: Farm House Jodupala.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

04/03/16

04/04/16

8.410
8.090
8.245

Failure
Load
(kN)
900
1000
1000

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.

Compressive
Strength (MPa)
40.00
44.44
44.44

3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16748

Date: 09/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Vastava Constructions, Chamundipuram, Mysuru.

Ref No

: Letter dated 07/04/16

Project*

: Site No. 1117, F-25, 1117/1, F 25/1, JLB road, Fort Mohalla,
Chamundipuram, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Pillar Footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-31/03/16
07/04/16
3
-* Information furnished by the client.

Weight
(Kg)
8.005
8.080
8.005

Failure
Load
(kN)
420
370
420

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Compressive
Strength (MPa)
18.67
16.44
18.67

Testing Officer

Head of the Dept

CRC No: 16743

Date: 07/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 06/04/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-06/03/16
06/04/16
3
-* Information furnished by the client.

Weight
(Kg)
7.990
8.105
7.815

Failure
Load
(kN)
680
940
645

Compressive
Strength (MPa)
30.22
41.78
28.67

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16753

Date: 11/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Vastava Constructions, Chamundipuram, Mysuru.

Ref No

: Letter dated 09/04/16

Project*

: Site No. 1117, F-25, 1117/1, F 25/1, JLB road, Fort Mohalla,
Chamundipuram, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Column.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-02/04/16
09/04/16
3
-* Information furnished by the client.

Weight
(Kg)
7.650
7.980
8.125

Failure
Load
(kN)
300
455
350

Compressive
Strength (MPa)
13.33
20.22
15.55

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16754

Date: 11/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Vastava Constructions, Chamundipuram, Mysuru.

Ref No

: Letter dated 09/04/16

Project*

: Site No. 1117, F-25, 1117/1, F 25/1, JLB road, Fort Mohalla,
Chamundipuram, Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Pillar footing.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-02/04/16
09/04/16
3
-* Information furnished by the client.

Weight
(Kg)
8.100
8.130
7.950

Failure
Load
(kN)
230
295
245

Compressive
Strength (MPa)
10.22
13.11
10.89

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16752

Date: 11/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Sri. Uttaradi Mutt , Mysore Branch, Kandayanagar,


Srirampura 2nd Stage, Mysuru.

Ref No

: Letter dated 11/03/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Retaining wall 3rd lift.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of
Casting
12/02/16

Date of
Testing

Weight
(Kg)

09/04/16

7.965
8.010
7.970

Failure
Load
(kN)
370
425
380

Compressive
Strength (MPa)
16.44
18.89
16.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16757

Date: 11/04/16
TEST REPORT

ON
Compressive Strength of Concrete Cubes
Client

: AEE, KHB, Kenchalagudu, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 08/04/16.

Project*

: Construction of C.H.S. at Kenchalagudu, Mysore under


KHB Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Trapizoidal Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of*
Casting
05/03/16

Date of
Testing

Weight
(Kg)

08/04/16

7.750
7.830
7.915

Failure
Load
(kN)
630
470
520

Compressive
Strength (MPa)
28.00
20.89
23.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16757

Date: 11/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KHB, Kenchalagudu, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 08/04/16.

Project*

: Construction of C.H.S. at Kenchalagudu, Mysore under


KHB Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Rect. Drain Wall.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

1
2
3

----

Date of *
Casting
04/03/16

Date of
Testing

Weight
(Kg)

08/04/16

7.805
7.655
7.825

Failure
Load
(kN)
250
505
250

Compressive
Strength (MPa)
11.11
22.44
11.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16757

Date: 11/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: AEE, KHB, Kenchalagudu, Mysuru.


Deviprasad Constructions Pvt Ltd.

Ref No

: Letter dated 08/04/16.

Project*

: Construction of C.H.S. at Kenchalagudu, Mysore under


KHB Mysore.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, Culvert Slab.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of*
Casting

Date of
Testing

Weight
(Kg)

----

01/04/16

08/04/16

7.970
7.965
8.065

Failure
Load
(kN)
370
380
380

Compressive
Strength (MPa)
16.44
18.89
18.89

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16764

Date: 13/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Executive Engineer, KUWS&DB City Division, JNNURM,


Mysuru.

Ref No

: Letter dated 12/04/16

Project*

: Construction of 10 LL capacity 12 mtr. Staging OHT at

Jayanagar Service Station premises inMysuru city under SCP


Grants for the year 2015-16.
Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20, PCC.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No
1
2
3

ID No.

Date of
Casting

Date of
Testing

Weight
(Kg)

----

15/03/16

12/04/16

8.040
8.100
8.285

Failure
Load
(kN)
670
600
565

Compressive
Strength (MPa)
29.78
26.67
25.11

1.* Information furnished by the client.


2. Report shall not be reproduced, without the written approval of the lab.
3. Any correction invalidates this report.
Testing Officer

Head of the Dept

CRC No: 16760

Date: 12/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Eminence Park, Srirampura 2nd stage,


BEML Layout, Mysore.

Ref No

: Letter dated 11/04/16.

Project*

: --

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-04/04/16
11/04/16
3
-* Information furnished by the client.

Weight
(Kg)
8.110
8.185
8.170

Failure
Load
(kN)
300
300
360

Compressive
Strength (MPa)
13.33
13.33
16.00

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16762

Date: 13/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: Great Sports Infra Pvt Ltd, Chamarajanagar.

Ref No

: --

Project*

: Construction of 400 Mtr. Synthetic Athletic Track with Sub


base and other allied works at Chamarajanagar.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M20.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen

: 150 mm x 150 mm x 150 mm

Sl
No

ID No.

Date of
Casting

Date of
Testing

1
-2
-05/04/16
12/04/16
3
-* Information furnished by the client.

Weight
(Kg)
8.065
8.160
7.915

Failure
Load
(kN)
200
195
200

Compressive
Strength (MPa)
8.89
8.67
8.89

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

CRC No: 16774

Date: 15/04/16
TEST REPORT
ON
Compressive Strength of Concrete Cubes

Client

: KPV Construction (K VENU), Mahajana College,


KRS Main Road, Mysore.

Ref No

: Letter dated 13/04/2016.

Project*

: Basket Ball Court of Mahajana Post Graduation College.

Source of Samples

: Sample Supplied by the Client.

Grade of Concrete*

: M25, Flooring.

Technical Reference

: IS 516 1959 (Reaffirmed 2004)

C/S Area of the specimen

: 22500 mm2

Size of the Specimen


Sl
No

ID No.

: 150 mm x 150 mm x 150 mm


Date of
Casting

Date of
Testing

1
-2
-06/04/16
13/04/16
3
-* Information furnished by the client.

Weight
(Kg)
8.380
8.195
8.200

Failure
Load
(kN)
560
580
500

Compressive
Strength (MPa)
24.89
25.78
25.33

Note: 1. Report shall not be reproduced, without the written approval of the lab.
2. Any correction invalidates this report.

Testing Officer

Head of the Dept

Вам также может понравиться