Вы находитесь на странице: 1из 9

PPS31 Wellhead Pressure Logger

User Manual (Rev. 01)

Pioneer Petrotech Services Inc.


Unit Q, 1235 - 40th Ave. NE
Calgary, AB T2E 6M9, Canada
Phone: 1-888-PP-GAUGE (774-2843)
E-mail: infopps@pioneerps.com
Web: http://www.pioneerps.com

INTRODUCTION.1
Your PPS31 Surface Pressure Logger Features..2
Overview of the PPS31 Logger...3
Using PPS31 Logger...3
Operating Modes....4
Power consumption of the PPS31 Surface Pressure Logger .5

Connecting to the Computer.......6


Connecting to The Computer.6

SOFTWARE and MAINTENANCE..7


Installing the PPS31 Software...7
Maintenance....7

INTRODUCTION
This manual is a step-by-step approach to the use, operation, maintenance, and
troubleshooting of PPS31surface pressure logger.
Pioneer Petrotech Services Inc. offers a wide range of oilfield related instruments.
These include memory and surface readout electronic pressure recorders, surface
pressure loggers, permanent installation systems, and DPT (downhole pressure
tools), all of which have been developed and manufactured to obtain the highest
accuracy and resolution in the industry.
Pioneer Petrotech Services Inc. offers products that are durable and reliable with
simple operational procedures. The lightweight design makes transportation to and
from test sites effortless. PPS has taken the data quality obtained from quartz and
sapphire transducers to new frontiers. In addition to the transducers, the state of the
art electronics and surface mount technology have enabled PPS to provide our
customers with top of the line quality pressure gauges.

Your PPS31 Surface Pressure Logger features


The PPS31 surface pressure logger is manufactured by using Silicon-Sapphire
transducers. New generation technology enables PPS to manufacture the worlds
most rugged pressure loggers to make field operations easier and more accurate.
Specification
Standard Pressure Ranges:
Pressure Accuracy:
Pressure Resolution:
Response Time:
Temperature Rating:
Temperature Accuracy:
Temperature Resolution:
Display:
Memory Capacity:
Data Sets Contents:
Memory Type:
Power Source:
Sampling Rate:
Transducer Type:
Work Mode:
Connection:

Up to 15,000 psi
0.03% Full Scale
0.0003%
Instantaneous
-40C(-40F) to 80C( 176F)
0.5C
0.01C
20 characters LCD
500,000 data sets (1,000,000 optional)
Time / Pressure / Temperature
non-volatile flash memory
Single D lithium pack (TL2300, two cells,
replaceable), up to one-year usage.
1 second to 18 hours per sample
Silicon-Sapphire
MRO/SRO
1/2 NPT

Label
Manufacturer
Pioneer Petrotech Services Inc.
Unit Q, 1235-40th Ave. NE
Calgary, AB Canada T2E 6M9
Type Designation
PPS31 Wellhead Pressure Logger
Marking
II 1 G Ex ia IIC T4

KEMA 08 ATEX 0141(X)

EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007


AMBIENT TEMPERATURE 40C to +55C
DUAL TADIRAN LITHIUM BATTERY (TL2300), D SIZE, 3.6 V, PARALLEL

Overview of the PPS31 System


The PPS31 system consists of the surface pressure logger, the interface box, and the
serial cable. PPS31 software can be run on any Pentium 100 MHZ computer or
higher with Windows 95/98/Me/2000/XP operating systems.
The surface pressure logger which is powered by an internal battery is connected to
one end of the interface box. The other end of the interface box is connected via an
RS232 cable to the Serial Port of the computer in order to set up the communication
between the surface pressure logger and the PPS31 software.

Using PPS31 Logger


Warning: An aluminum enclosure is used. In a hazardous area, any impact and/or
friction shall be avoided.

Warning: In a hazardous area, the non-metallic parts represent an electrostatic


hazard and are NOT be cleaned with a dry cloth.

The PPS31 logger has several switches controlling different functions. The switch
button on the right side of the logger turns on/off the LCD where you read the
current pressure and temperature from. (See the picture below)
Micro switches
Display On button

Radio antenna
(Optional)

The switches under the cover lens are used to turn the logger on/off and to convert
the pressure and temperature units correspondingly. (See the picture below)
On turn the logger on
Off turn the logger off
On display pressure in
metric units (kPa, C)
Off display pressure in
imperial units (psi, F)

Operating Modes
The surface pressure logger can operate in three different modes: Sampling Mode,
Stand-by Mode, and Communication Mode.
Sampling Mode: The tool is in Sampling Mode when a battery is
connected to the surface pressure logger without the interface box and cable
attached to it. Under normal operating conditions the logger is programmed
and then transported to the surface.
The logger carries out the program in accordance with the instructions prestored in the memory.
Stand-by Mode: The logger is in Stand-by Mode when it is not sampling
(i.e. in between the samples). PPS loggers are designed to switch to Stand-by
Mode automatically between samples.
Communication Mode: The surface logger is in Communication Mode
when the interface box and cable are connected to both the logger and the
computer. This Mode is used to program the logger, download data from the
logger, and perform other related operations through the software.

Power Consumption Of The PPS31 pressure logger


The PPS31 loggers are designed to consume the lowest power; therefore, the battery
life can be extended to save operational expenses for our customers.
Power consumption at different modes is as follows:
Stand-by Mode: 0.8 mA.
Sampling Mode: 3 mA.
Communication Mode: 10 mA.

Warning: TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE,


BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO
BE NON-HAZARDOUS.
MAINTENANCE IS ONLY TO BE DONE WITH THE POWER
DISCONNECTED SUBSTITUTION OF COMPONENTS MAY IMPAIR
INTRINSIC SAFETY.

Connecting To the Computer


1.
2.
3.
4.
5.

Connect the logger to the computer using the interface box through the USB port.
Program the logger using the SmartView software.
Disconnect the interface box after programming
Install logger on to the wellhead and let it start working.
Logger is uninstalled from wellhead and moved to a safe place.
6. Connect the logger to the computer again to download and process the data
recorded.

Warning: Do not use the Interface Box with your computer at places where
explosive or flammable gases are present, due to a safety concern
(spark). Please program the gauge at a safe location before installing it
on-site or putting it into well.

Installing The PPS31 Software


All the files needed to install your PPS31 software are supplied on two diskettes.
These disks are numbered because they are used in a specific order by the
installation routine. To install the PPS31 software, Please see Software Manual.

Maintenance
Display check:
Turn on the power to check the display. If the display works regularly, it will
sleep when the black button is pushed.
Push again the black button to restart the display.
The Crossover and the gauge housing should be tied up.

O-ring For Logger Crossover


116

Be sure that the screw is


unscrewed every time before
taking off the cover.

O-ring 242
Important For Waterproof &Sealing