Check whether the alarm is cleared.

Y => The alarm is cleared. No further action is required.


N => The alarm is not cleared. Go to step 5.
3. Check the site and related engineering connections.
a. Check whether the site is newly deployed without commercial operation.
Y => The site is newly deployed without commercial operation. In this case, the
alarm handling is not
necessary.
N => The site is not a new site. Go to step 4.
4. Check for related alarms and check the modules and cables.
a. Check for the correlated alarms of the site on the M2000:
26529 RF Unit VSWR Threshold Crossed
28011 RF Unit RX Channel Fault
Y => The correlated alarm exists. Go to sub-step b.
N => The correlated alarm does not exist. Go to step 5.
b. Clear the correlated alarm according to the relevant handling