Академический Документы
Профессиональный Документы
Культура Документы
Long.
Parameter ID
1
2
3
4
5
6
7
8
9
10
11
Lat.
Parameter Name
Longitude
Latitude
Cell Name
Cell ID
MCC
MNC
LAC
NCC
BCC
BcchAfrcn
Cell Type
Cell Name
GSM Cell ID
MCC
Cell_1
12321
404
Default value
Description
LAC
NCC
BCC
BcchAfrcn
Cell Type
GSM
for example
Below is the key 2G to 3G reselectiong patametres which need BSNL to do the configeration.
Parameter ID
Parameter Name
Qsearch I
FDD Q Offset
FDD Qmin
Default value
-10dB
0dB
This parameter indicates the threshold of level for cell reselection in idle
mode.
In idle mode, if the signal level in the service cell is below (0-7) or above (815), the MS starts to search for 3G cells.
Only when the average receive level of a 3G cells is FDD Q Offset greater
than that of the current service cell, the 3G cell can become a candidate cell
This parameter indicates one of the threshold of level for the reselection of
3G cells. Only when the receive level of a 3G cell is greater than FDD Qmin,
the 3G cell can be one of the candidate cells for reselection.
3G Information - Huawei should provide the updated 3G information database to other vendor.
Long.
Parameter ID
1
2
3
4
5
6
7
8
9
Lat.
Parameter Name
Longitude
Latitude
Cell Name
Cell ID
MCC
MNC
LAC
PSC
AFRCN
Cell Name
Default value
3G Cell ID
MCC
Description
3G Cell name
3G Cell ID
Mobile Country Code
3G Mobile Network Code
3G Location Area Code
Primary Scrambling Code
3G absolute frequency channel NO.
3G LAC
PSC
AFRCN
Parameter ID
Parameter Name
Default value
Qoffset1sn
Qrxlevmin
Min RX level[dBm]
QualMeas
Cell Sel-reselection
quality measure
IdleQhyst1s
ConnQhyst1s
IdleQhyst2s
ConnQhyst2s
Treselections
-50
CPICH Ec/N0
Qqualmin
-18
Qrxlevmin
Min Rx level
-58
SsearchRat
Description
Parameter ID
Parameter Name
INTER_RAT_CS_OUT_SWITCH
INTER_RAT_PS_OUT_SWITCH
Default value
Description
323627584.xls
Parameter ID
Parameter Name
InterRATReportMode
Security Level:
Default value
PERIODICAL_REPORTING
MeasQuantityOf2D2F
BOTH
FilterCoefOf2D2F
D3
InterRATFilterCoef
D3
WeightForUsedFreq
InterRATPeriodReportInterval
D1000
07/12/2016
Page13of22
323627584.xls
Hystfor2D
Security Level:
2D hysteresis[0.5dB]
Hystfor2F
2F hysteresis[0.5dB]
HystforInterRAT
Inter-RAT hysteresis[0.5dB]
TrigTime2D
D320
TrigTime2F
D1280
TimeToTrigForVerify
07/12/2016
Page14of22
323627584.xls
BSICVerify
Security Level:
REQUIRE
InterRATCSThd2DEcN0
-14
InterRATCSThd2FEcN0
-12
InterRATR99PsThd2DEcN0
-15
InterRATR99PsThd2FEcN0
-13
InterRATCSThd2DRSCP
-100
07/12/2016
Page15of22
323627584.xls
InterRATCSThd2FRSCP
Security Level:
-97
InterRATR99PsThd2DRSCP
-110
InterRATR99PsThd2FRSCP
-107
InterRATCovHOCSThd
16
07/12/2016
Page16of22
323627584.xls
TargetRatR99PsThd
Security Level:
16
PenaltyTimeforInterRATHO
InterRATMeasTime
Inter-RAT measure timer
length[s]
60
InterRATPingPongTimer
InterRATPingPongHyst
07/12/2016
Page17of22
323627584.xls
Security Level:
Description
Inter-RAT measurement report mode
Value range:
- PERIODICAL_REPORTING: periodical inter-RAT measurement report
- EVENT_TRIGGER: event-triggered inter-RAT measurement report
07/12/2016
Page18of22
323627584.xls
Security Level:
Time delay for triggering handovers to GSM cells with non-verified BSIC
Value range: 0~64000, 65535
Physical unit: ms
Content: During the period of time specified by this parameter, if the signal quality in a
neighboring GSM cell satisfies inter-RAT handover conditions and the neighboring GSM
cell is not verified, an inter-RAT handover is triggered. When the value of this parameter is
65535, the RNC does not perform inter-RAT handovers to non-verified GSM cells.
07/12/2016
Page19of22
323627584.xls
Security Level:
07/12/2016
Page20of22
323627584.xls
Security Level:
Quality requirement for the inter-RAT cell during an inter-RAT handover with CS domain
services
Value range: 0~63
Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to
-109, ..., 63 to -48.)
Physical unit: dBm
Content: For CS domain services,
- If the value of [Inter-RAT report mode] is EVENT_TRIGGER, this parameter is used to set
the measurement control on the event 3A. The event 3A is triggered, when the quality of
the cell with the target frequency is higher than this threshold and the threshold of the used
frequency quality of the corresponding measurement quantity is reached.
- If the value of [Inter-RAT report mode] is PERIODICAL_REPORTING, this parameter is
used to evaluate coverage-based inter-RAT handovers at the RNC.
Note that the value 0 means the physical value is smaller than -110 dBm.
07/12/2016
Page21of22
323627584.xls
Security Level:
Quality requirement for the inter-RAT cell during an inter-RAT handover with PS domain
R99 services
Value range: 0~63
Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to
-109, ..., 63 to -48.)
Physical unit: dBm
Content: For PS domain R99 services,
- If the value of [Inter-RAT report mode] is EVENT_TRIGGER, this parameter is used to set
the measurement control on the event 3A. The event 3A is triggered, when the quality of
the cell with the target frequency is higher than this threshold and the threshold of the used
frequency quality of the corresponding measurement quantity is reached.
- If the value of [Inter-RAT report mode] is PERIODICAL_REPORTING, this parameter is
used to evaluate coverage-based inter-RAT handovers at the RNC.
Note that the value 0 means the physical value is smaller than -110 dBm.
Penalty timer length after an inter-RAT handover failure
Value range: 0~65535
Physical unit: s
Content: An inter-RAT handover to a GSM cell may fail due to the heavy load of the GSM
cell. Therefore, in the period of time specified by this parameter, inter-RAT handover
requests cannot be sent to the GSM cell.
07/12/2016
Page22of22