Вы находитесь на странице: 1из 22

2G Information - BSNL should provide the updated 2G informaiton database in the trial area to

Long.

Parameter ID

1
2
3
4
5
6
7
8
9
10
11

Lat.

Parameter Name

Longitude
Latitude
Cell Name
Cell ID
MCC
MNC
LAC
NCC
BCC
BcchAfrcn
Cell Type

Cell Name

GSM Cell ID

MCC

Cell_1

12321

404

Default value

Description

The unique Cell name in the network.


The unique ID to indicate Cell.
Mobile Country Code
Mobile Network Code
Location Area Code
Network Color Code.The unique indicate for differ
BTS Color Code.The unique indicate for different n
GSM cell frequency NO.
GSM\GPRS\EDGE

database in the trial area to Huawei.


MNC

LAC

NCC

BCC

BcchAfrcn

Cell Type

GSM

name in the network.


indicate Cell.

ode.The unique indicate for different nearby network.


The unique indicate for different nearby BTS which use the same frequency.

for example

Below is the key 2G to 3G reselectiong patametres which need BSNL to do the configeration.
Parameter ID

Parameter Name

Qsearch I

FDD Q Offset

FDD Qmin

Default value

-10dB

0dB

etres which need BSNL to do the configeration.


Description

This parameter indicates the threshold of level for cell reselection in idle
mode.
In idle mode, if the signal level in the service cell is below (0-7) or above (815), the MS starts to search for 3G cells.
Only when the average receive level of a 3G cells is FDD Q Offset greater
than that of the current service cell, the 3G cell can become a candidate cell
This parameter indicates one of the threshold of level for the reselection of
3G cells. Only when the receive level of a 3G cell is greater than FDD Qmin,
the 3G cell can be one of the candidate cells for reselection.

3G Information - Huawei should provide the updated 3G information database to other vendor.
Long.

Parameter ID

1
2
3
4
5
6
7
8
9

Lat.

Parameter Name

Longitude
Latitude
Cell Name
Cell ID
MCC
MNC
LAC
PSC
AFRCN

Cell Name

Default value

3G Cell ID

MCC

Description

3G Cell name
3G Cell ID
Mobile Country Code
3G Mobile Network Code
3G Location Area Code
Primary Scrambling Code
3G absolute frequency channel NO.

database to other vendor. And operator should add 2G to 3G related parameters.


MNC

ncy channel NO.

3G LAC

PSC

AFRCN

Parameter ID

Parameter Name

Default value

Qoffset1sn

Offset between inter-RAT


neighboring cell and
WCDMA cell

Qrxlevmin

Min RX level[dBm]

QualMeas

Cell Sel-reselection
quality measure

IdleQhyst1s

Hysteresis 1 for idle


mode

ConnQhyst1s

Hysteresis 1 for connect


mode

IdleQhyst2s

Hysteresis 2 for idle


mode

ConnQhyst2s

Hysteresis 2 for connect


mode

Treselections

Reselection delay time

-50

CPICH Ec/N0

Qqualmin

Min quality level

-18

Qrxlevmin

Min Rx level

-58

SsearchRat

Inter-RAT cell reselection


threshold

Description

Offset between inter-RAT neighboring cell and WCDMA cell


Value range: -50~50 Physical unit: dB Content: This parameter is used in inter-RAT
handover decision. The larger the parameter, the higher the handover priority of
the GSM cell. The smaller the parameter, the lower the handover priority of the
GSM cell.
Minimum RX level of the GSM cell.
Value range: -58 to -13; step: 1 Physical value range: -115 to -25; step: 2 Physical
unit: dBm Content: Before the UE reselect this cell, measure the signal quality first.
If the signal quality is better than this parameter value, the UE can acquire high
QoS in this cell and be admitted to reselect this cell. If the signal quality is worse
than this parameter value, the UE cannot acquire high QoS in this cell or be
admitted to reselect this cell.
Cell Sel-reselection quality measure
Value range: CPICH_ECNO(CPICH Ec/N0),CPICH_RSCP(CPICH RSCP) Physical unit:
None. Content: Cell selection and reselection quality measure,may be set to CPICH
Ec/N0 or CPICH RSCP.
Hysteresis 1 for idle mode
Value range: 0~20. Physical value range: 0~40; step: 2. Physical unit: dB. Content:
The hysteresis value in idle mode for serving FDD cells in case the quality
measurement for cell selection and reselection is set to CPICH RSCP. It is related to
the slow fading feature of the area where the cell is located. The greater the slow
fading variance is, the greater this parameter.
Hysteresis 1 for connect mode
Value range: 0~20. Physical value range: 0~40; step: 2. Physical unit: dB. Content:
The hysteresis value in connect mode for serving FDD cells in case the quality
measurement for cell selection and reselection is set to CPICH RSCP. It is related to
the slow fading feature of the area where the cell is located. The greater the slow
fading variance is, the greater this parameter.
Hysteresis 2 for idle mode
Value range: {{0~20},{255}}. Physical value range: 0~40; step: 2. Physical unit:
dB. Content: The hysteresis value in idle mode for serving FDD cells in case the
quality measurement for cell selection and reselection is set to CPICH Ec/No. It is
related to the slow fading feature of the area where the cell is located. The greater
the slow fading variance is, the greater this parameter. It is optional. If it is not
configured, [Hysteresis 1] will be adopted as the value. This parameter is not
configured when its value is 255.
Hysteresis 2 for connect mode
Value range: {{0~20},{255}}. Physical value range: 0~40; step: 2. Physical unit:
dB. Content: The hysteresis value in connect mode for serving FDD cells in case the
quality measurement for cell selection and reselection is set to CPICH RSCP. It is
related to the slow fading feature of the area where the cell is located. The greater
the slow fading variance is, the greater this parameter. This parameter is not
configured when its value is 255.Recommended value: CPICH_ECNO.
Reselection delay time
Value range: 0~31. Physical unit: s. Content: If the signal quality of a neighboring
cell is better than the serving cell during the specified time of this parameter, the
UE will reselect the neighboring cell. It is used to avoid ping-pong reselection
between different cells. Note: The value 0 corresponds to the default value defined
in the protocol.

Min quality level[dB]


Value range: -24~0. Physical unit: dB. Content: The minimum required quality level
corresponding to CPICH Ec/No. The UE can camp on the cell only when the
measured CPICH Ec/No is greater than the value of this parameter.
Min Rx level
Value range: -58~-13. Physical value range: -115~-25; step: 2 (-58:-115; -57:113; ..., - 13:25 ). Physical unit: dBm. Content: The minimum required RX level
corresponding to CPICH RSCP. The UE can camp on the cell only when the measured
CPICH RSCP is greater than the value of this parameter.
Inter-RAT cell reselection threshold
Value range: {{-16~10},{127}}. Physical value range: -32~20; step: 2. Physical
unit: dB. Content: A threshold for inter-RAT cell reselection. When the quality (CPICH
Ec/No measured by UE) of the serving cell is lower than this threshold plus the
[Qqualmin] of the cell, the inter-RAT cell reselection procedure will be started. This
parameter is not configured when its value is 127.

Parameter ID

Parameter Name

INTER_RAT_CS_OUT_SWITCH

INTER RAT CS SWITCH

INTER_RAT_PS_OUT_SWITCH

INTER RAT PS SWITCH

Default value

Description

When it is checked, the inter-frequency measurement is


allowed or the inter-frequency hard handover based on cell
1 load is allowed.
When it is checked and the license is enabled, RNC initiates
inter-RAT measurement to trigger inter-RAT handover of the PS
1 domain from UTRAN.

323627584.xls

Parameter ID

Parameter Name

InterRATReportMode

Inter-RAT report mode

Security Level:

Default value

PERIODICAL_REPORTING

MeasQuantityOf2D2F

2D2F Measure Quantity

BOTH

FilterCoefOf2D2F

2D2F filter coeff

D3

InterRATFilterCoef

Inter-RAT filter coeff

D3

WeightForUsedFreq

Weight for Used frequency

InterRATPeriodReportInterval

Inter-RAT period report


interval[ms]

D1000

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page13of22

323627584.xls

Hystfor2D

Security Level:

2D hysteresis[0.5dB]

Hystfor2F

2F hysteresis[0.5dB]

HystforInterRAT

Inter-RAT hysteresis[0.5dB]

TrigTime2D

2D event trigger delay time[ms]

D320

TrigTime2F

2F event trigger delay time[ms]

D1280

TimeToTrigForVerify

Time to trigger for verified GSM


cell[ms]

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page14of22

323627584.xls

BSICVerify

Security Level:

BSIC verify switch

REQUIRE

InterRATCSThd2DEcN0

Inter-RAT CS measure start


Ec/No THD[dB]

-14

InterRATCSThd2FEcN0

Inter-RAT CS measure stop


Ec/No THD[dB]

-12

InterRATR99PsThd2DEcN0

Inter-RAT R99 PS measure start


Ec/No THD[dB]

-15

InterRATR99PsThd2FEcN0

Inter-RAT R99 PS measure stop


Ec/No THD[dB]

-13

InterRATCSThd2DRSCP

Inter-RAT CS measure start


RSCP THD[dBm]

-100

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page15of22

323627584.xls

InterRATCSThd2FRSCP

Security Level:

Inter-RAT CS measure stop


RSCP THD[dBm]

-97

InterRATR99PsThd2DRSCP

Inter-RAT R99 PS measure start


RSCP THD[dBm]

-110

InterRATR99PsThd2FRSCP

Inter-RAT R99 PS measure stop


RSCP THD[dBm]

-107

InterRATCovHOCSThd

Inter-RAT CS handover decision


THD[dBm]

16

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page16of22

323627584.xls

TargetRatR99PsThd

Security Level:

Inter-RAT R99 PS handover


decision THD[dBm]

16

PenaltyTimeforInterRATHO

Inter-RAT handover failure


penalty timer length[s]
30

InterRATMeasTime
Inter-RAT measure timer
length[s]

60

Inter-RAT PingPong timer[s]

InterRATPingPongTimer

InterRATPingPongHyst

Inter-RAT PingPong Hyst[0.5dB] 0

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page17of22

323627584.xls

Security Level:

Description
Inter-RAT measurement report mode
Value range:
- PERIODICAL_REPORTING: periodical inter-RAT measurement report
- EVENT_TRIGGER: event-triggered inter-RAT measurement report

Measurement quantity used in coverage-based inter-RAT measurement in event-2D- or


event-2F-triggered reporting mode.
Value range: CPICH_Ec/No,CPICH_RSCP,BOTH
Content:
- CPICH: Common Pilot Channel
- Ec/No: Signal-to-Noise Ratio
- RSCP: Received Signal Code Power
- CPICH_Ec/No: to use the Ec/No measurement quantity for event 2D or event 2F
measurement. The physical unit is dB.
- CPICH_RSCP: to use the RSCP measurement quantity for event 2D or event 2F
measurement. The physical unit is dBm.
- BOTH: the RNC sends two Active Set Quality Measurement with different measurement
quantity. Valid when Inter-System measurement chooses PERIODICAL_REPORTING
mode.

L3 filtering coefficient for event 2D or event 2F measurement


Value range: D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D11, D13, D15, D17, D19
Physical value range: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19
Content: The larger the value of this parameter, the stronger the smoothing effect and the
higher the anti-fast-fading capability, but the lower the signal change tracing capability.

L3 filtering coefficient for inter-RAT measurement


Value range: D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D11, D13, D15, D17, D19
Physical value range: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19
Content: The larger the value of this parameter, the stronger the smoothing effect and the
higher the anti-fast-fading capability, but the lower the signal change tracing capability.

Weight used for computing frequency general quality


Value range: 0~20
Physical value range: 0~2; step: 0.1
Content: The larger the value of this parameter, the higher the the calculated general
quality of an active set. When the value is set to 0, the general quality of an active set is the
quality of the best cell in the set. This parameter is used for event 3A evaluation.

Interval that the UE reports inter-RAT measurement results to the RNC


Value range: NON_PERIODIC_REPORT, D250, D500, D1000, D2000, D3000, D4000,
D6000, D8000, D12000, D16000, D20000, D24000, D28000, D32000, D64000
Physical value range: NON_PERIODIC_REPORT, 250, 500, 1000, 2000, 3000, 4000,
6000, 8000, 12000, 16000, 20000, 24000, 28000, 32000, 64000
Physical unit: ms
Content: In periodical reporting mode, the interval between two reports is the configured
value. That is, the UE submits reports at intervals of the configured time.It is not suggested
to use value 'NON_PERIODIC_REPORT', otherwise the UE behaviour is not defined.

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page18of22

323627584.xls

Security Level:

Hysteresis value for the event 2D


Value range: 0~29
Physical value range: 0~14.5, step: 0.5
Physical unit: dB
Content: The value of this parameter is relevant to the slow fading characteristic. The larger
the value of this parameter, the less the ping-pong effect and the fewer the decision
mistakes. In this case, however, the event 2D might not be triggered in time.

Hysteresis value for the event 2F


Value range: 0~29
Physical value range: 0~14.5, step: 0.5
Physical unit: dB
Content: The value of this parameter is relevant to the slow fading characteristic. The larger
the value of this parameter, the less the ping-pong effect and the fewer the decision
mistakes. In this case, however, the event 2F might not be triggered in time.
Hysteresis value for inter-RAT measurement periodical reports
Value range: 0~15
Physical value range: 0~7.5, step: 0.5
Physical unit: dB
Content: This parameter, together with the quality threshold, decides whether to trigger
inter-RAT handovers. The smaller the shadow fading is, the smaller the parameter value
should be.

Time delay to trigger the event 2D


Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640,
D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,
5000
Physical unit: ms
Content: The value of this parameter is relevant to the slow fading characteristic. The larger
the value of this parameter, the lower the incorrect decision probability, but the slower the
response of the event 2D to measurement signal change.

Time delay to trigger the event 2F


Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640,
D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,
5000
Physical unit: ms
Content: The value of this parameter is relevant to the slow fading characteristic. The larger
the value of this parameter, the lower the incorrect decision probability, but the slower the
response of the event 2F to measurement signal change.

Time delay for triggering handovers to GSM cells with non-verified BSIC
Value range: 0~64000, 65535
Physical unit: ms
Content: During the period of time specified by this parameter, if the signal quality in a
neighboring GSM cell satisfies inter-RAT handover conditions and the neighboring GSM
cell is not verified, an inter-RAT handover is triggered. When the value of this parameter is
65535, the RNC does not perform inter-RAT handovers to non-verified GSM cells.

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page19of22

323627584.xls

Security Level:

Base transceiver Station Identity Code (BSIC) verification switch


Value range: REQUIRED, NOT_REQUIRE
Content: This parameter is used to control cells where inter-RAT measurement reports are
triggered.
- When the value is REQUIRED, the measurement report is triggered after the BSIC of the
measured cell is deciphered correctly.
- When the value is NOT_REQUIRE, measurement resporting is triggered no matter the
BSIC is deciphered or not, if the measured cell satisfies the reporting conditions.

Threshold to trigger inter-RAT measurement with measurement quantity of Ec/No for CS


domain services
Value range: -24~0
Physical unit: dB
Content: For CS domain services, when Ec/No is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to activate compressed mode and
start inter-RAT measurement, if the UE reports the event 2D when the measured value is
smaller than the value of this parameter.

Threshold to trigger inter-RAT measurement with measurement quantity of Ec/No for CS


domain services
Value range: -24~0
Physical unit: dB
Content: For CS domain services, when Ec/No is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to activate compressed mode and
start inter-RAT measurement, if the UE reports the event 2D when the measured value is
smaller than the value of this parameter.

Threshold to trigger inter-RAT measurement with measurement quantity of Ec/No for PS


domain R99 services
Value range: -24~0
Physical unit: dB
Content: For PS domain R99 services, when Ec/No is used as the measurement quantity
for inter-RAT measurement, the RNC sends the signaling to activate compressed mode
and start inter-RAT measurement, if the UE reports the event 2D when the measured value
is smaller than the value of this parameter.

Threshold to stop inter-RAT measurement with measurement quantity of Ec/No for PS


domain R99 services
Value range: -24~0
Physical unit: dB
Content: For PS domain R99 services, when Ec/No is used as the measurement quantity
for inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode
and stop inter-RAT measurement, if the UE reports the event 2F when the measured value
is larger than the value of this parameter.

Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for CS


domain services
Value range: -115~-25
Physical unit: dBm
Content: For CS domain services, when RSCP is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to activate compressed mode and
start inter-RAT measurement, if the UE reports the event 2D when the measured value is
smaller than the value of this parameter.

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page20of22

323627584.xls

Security Level:

Threshold to stop inter-RAT measurement with measurement quantity of RSCP for CS


domain services
Value range: -115~-25
Physical unit: dBm
Content: For CS domain services, when RSCP is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode and
stop inter-RAT measurement, if the UE reports the event 2F when the measured value is
larger than the value of this parameter.

Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for PS


domain R99 services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain R99 services, when RSCP is used as the measurement quantity
for inter-RAT measurement, the RNC sends the signaling to activate compressed mode
and start inter-RAT measurement, if the UE reports the event 2D when the measured value
is smaller than the value of this parameter.

Threshold to stop inter-RAT measurement with measurement quantity of RSCP for PS


domain R99 services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain R99 services, when RSCP is used as the measurement quantity
for inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode
and stop inter-RAT measurement, if the UE reports the event 2F when the measured value
is larger than the value of this parameter.
Recommended value (default value): -107

Quality requirement for the inter-RAT cell during an inter-RAT handover with CS domain
services
Value range: 0~63
Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to
-109, ..., 63 to -48.)
Physical unit: dBm
Content: For CS domain services,
- If the value of [Inter-RAT report mode] is EVENT_TRIGGER, this parameter is used to set
the measurement control on the event 3A. The event 3A is triggered, when the quality of
the cell with the target frequency is higher than this threshold and the threshold of the used
frequency quality of the corresponding measurement quantity is reached.
- If the value of [Inter-RAT report mode] is PERIODICAL_REPORTING, this parameter is
used to evaluate coverage-based inter-RAT handovers at the RNC.
Note that the value 0 means the physical value is smaller than -110 dBm.

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page21of22

323627584.xls

Security Level:

Quality requirement for the inter-RAT cell during an inter-RAT handover with PS domain
R99 services
Value range: 0~63
Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to
-109, ..., 63 to -48.)
Physical unit: dBm
Content: For PS domain R99 services,
- If the value of [Inter-RAT report mode] is EVENT_TRIGGER, this parameter is used to set
the measurement control on the event 3A. The event 3A is triggered, when the quality of
the cell with the target frequency is higher than this threshold and the threshold of the used
frequency quality of the corresponding measurement quantity is reached.
- If the value of [Inter-RAT report mode] is PERIODICAL_REPORTING, this parameter is
used to evaluate coverage-based inter-RAT handovers at the RNC.
Note that the value 0 means the physical value is smaller than -110 dBm.
Penalty timer length after an inter-RAT handover failure
Value range: 0~65535
Physical unit: s
Content: An inter-RAT handover to a GSM cell may fail due to the heavy load of the GSM
cell. Therefore, in the period of time specified by this parameter, inter-RAT handover
requests cannot be sent to the GSM cell.

Timer length for inter-RAT measurement


Value range: 0~512
Physical unit: s
Content: After inter-RAT measurement starts, if no inter-RAT handover is performed when
this timer times out, the inter-RAT measurement is stopped. In addition, the compressed
mode is deactivated, if any. The value 0 indicates the timer is not to be enabled.

Inter-RAT PingPong timer


Value range:0~65535.
Physical unit:s.
Content: When UE handover form 2G network to 3G network, if any CS domain service
exists, the system increase 3A Hysteresis to prevent UE ping-pong handover between 2G
network and 3G network in the period specified by this parameter.If this parameter is 0,the
system will not start the ping-pong handover punish timer.

Inter-RAT PingPong Hyst


Value range: 0~15
Physical value range: 0~7.5, step: 0.5
Physical unit: dB
Content: When UE handover form 2G network to 3G network, if any CS domain service
exists, the system increase 3A Hysteresis specified by this parameter to prevent UE pingpong handover between 2G network and 3G network.If this parameter is 0,the system will
not start the ping-pong handover punish timer.

07/12/2016

Confidential Information of Huawei.


No Spreading without Permission

Page22of22

Вам также может понравиться