CEILING MOUNT TYPE

KCE Series

CEILING MOUNT TYPE KCE

SERIES

Features
A. Round spigot opening for easy
connection to flexible hose.
B. Non return flap to prevent back-flow.
C. Body made of high impact ABS plastic.
D. Balanced turbine with new wide angle,
curved blade for quiet operation and
high air volume.
E. High static pressure design for ducted air
handling.
F. Capacitor operated motor with thermal
switch.
G. Spring Clip on front cover easily
removable for cleaning.
H. Modern discreet designed cover in white.

KCE 100X/120X/160X/250X

KCE 300M/400M/600M

Technical Data
Model
KCE 100X
KCE 120X
KCE 160X
KCE 250X
KCE 300M
KCE 400M
KCE 600M

Max. Flow
m3/h

Max. Press.
Pa

N
Poles

Power
W

Hz

Max
Amp

Class
Insulation

dB (A)
at 3m

RPM

Weight
kg

90/104
110/120
150/137
250/230
349/335
450/367
432/356
634/533
590/490

48/70
54/78
108/122
152/186
125/131
190/165
218/177
246/218
266/213

4
4
4
4
4
4
4
4
4

30/30
30/30
35/35
60/60
32/32
45/45
45/45
85/85
85/85

50/60
50/60
50/60
50/60
50/60
50
60
50
60

0.10/0.10
0.09/0.09
0.09/0.09
0.16/0.18
0.13/0.16
0.21/0.17
0.24/0.17
0.28/0.43
0.52/0.43

E
E
E
E
A
A
A
A
A

38/38
40/40
40/40
44/45
32/32
42/40
42/40
46/44
46/44

1105/1283
1289/1245
1250/1500
1250/1500
1115/1135
1221/1133
1304/1162
1219/1155
1260/1137

1.1
1.5
1.5
2.6
5
6.5
6.5
9
9

Performance

KCE 100X

0
8

70

56.5

50 Hz

Static Pressure (Pa)

200
3.5

97

11

180

179

60

60 Hz

50
40
30
20
10

17

0
0

200

KCE 120X

00
1

20

40

60

80

100

80
50 Hz

92
4.5

60

40

20

160

35

225
251

60 Hz

Static Pressure (Pa)

280

120

Air Flow (m3/h)

18

0
0

20

40

KCE 160X

60

80

100

120

280

Air Flow (m /h)

00
1

140

99

50 Hz

Static Pressure (Pa)

310
5

37

175

266

288

120

60 Hz

100
80
60
40
20

18

0
0

25

50

310

KCE 250X

48
1

75
100
Air Flow (m3/h)

125

200
50 Hz
60 Hz

Static Pressure (Pa)

115
366
5

100

50

37

180

150

24

330

308

150

366

50

100

150

Air Flow (m3/h)

200

250

Performance

KCE 300M
200
50Hz

Static Pressure (Pa)

60Hz

150

100

50

0
0

KCE 400M

100

200
300
Air Flow (m3/h)

400

500

Static Pressure (Pa)

50Hz
200
High

150

Low

100
50
0
0

100

200

300

400

500

Air Flow (m3/h)

Static Pressure (Pa)

60Hz
200
High

150

Low

100
50
0
0

100

200

300

400

500

Air Flow (m /h)

KCE 600M
Static Pressure (Pa)

50Hz
250
High

200

Low

150
100
50
0
0

100

200

300

400

500

600

700

Air Flow (m3/h)

Static Pressure (Pa)

60Hz
250
High

200

Low

150
100
50
0
0

100

200

300

400

Air Flow (m3/h)

500

600

700

Installation Guide

Option 1

False Ceiling

Option 2

False Ceiling