Вы находитесь на странице: 1из 8

Multidrive modules main features

Benefits

Features

Note

Integration and compact


size

Small size
Options inside the drive

The inverter modules are dramatically smaller. The


average length of the multidrive line-up has now been cut
to half the previous size.

Construction simpler

Modular and redundant


Fewer spare parts
Innovative design

Power modules are available in 7 different sizes (R2i-R5i,


R6i, R7i, R8i) starting from 3 kVA for motor inverters and
70 kVA for line supply.
All the powers from about 1702430 kVA are different
configurations of R8i units, single or in parallel. Only four
types of diode rectifier units cover the power range of
2004540 kVA.
The modules have a plug-in connector, meaning very
easy assembling. The modules are also equipped with
wheels, which enables fast maintenance. The modules
can be freely connected in parallel for higher output
current. This means a limited number of different module
sizes andfewer spare parts.

Global product

Global feasibility
Standards, product approvals

Worldwide service

Common ABB drive


technology

Industrial drive platform

Common control platform


Software
Same spare parts
Less training

Premium Technology

DTC -Direct Torque Control

The heart of the multidrive is DTC - Direct Torque Control,


its first class motor control system. The consistently
excellent performance of the multidrive guarantees that
the drive is not the limiting factor in your process.
DTC technology is well proven in various applications and
demanding environments guaranteeing the high reliability
of the drive.

IndustrialIT for drives

As a key element of its business


strategy, ABB has committed to a broad
program of product development and
positioning under the IndustrialIT umbrella.
This initiative is geared towards increasing
standardization of ABB products as the
"building blocks" of larger solutions,
while building in functionality that will
allow multiple products to interact
seamlessly as components of real-time
automation and information systems.

3AFE 68248531 REV A EN 31.3.2004

17

Multidrive modules ratings, types and voltages


Drive module, UN= 400 V
ACS800

X04

No-overload
Nominal
use
ratings
Pcont. max
Icont. max
Imax

0003

Light-overload
use
PN
IN

kW
A
A
kW
UN = 400 V (Range 380 - 415 V)
1.5
5.1
7
1.5
2.2
6.5
8
2.2
3
8.5
11
3.0
4
11
14
4.0
5.5
14
18
5.5
7.5
19
24
7.5
11
25
32
11
15
34
46
15
22
44
62
18.5
30
55
72
22
37
72
86
30
45
86
112
37
55
103
138
45
75
147
224
75
90
178
294
90
132
250
342
110
160
292
400
132
200
370
506
200
250
469
642
250
315
565
773
300
400
741
1014
400
630
1111
1521
560
900
1452
1988
710
1250
2156
2951
1120
1600
2845
3894
1600

Heavy-duty
use
Phd
Ihd

kW

Heat
dissipation
kW

4.7
5.9
7.7
10.2
12.7
18
24
31
41
50
69
80
94
141
171
240
280
355
450
542
711
1067
1394
2070
2731

1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5
22
30
37
55
75
90
110
132
200
220
315
450
560
900
1120

3.4
4.3
5.7
7.5
9.3
14
19
23
32
37
49
60
69
112
147
187
218
277
351
423
554
831
1086
1613
2128

0.1
0.1
0.1
0.1
0.2
0.3
0.3
0.4
0.5
0.6
0.8
1.0
1.2
1.5
1.8
2.2
2.7
3.7
4.5
5.8
7.9
11.4
15.3
22.5
29.5

XXXX

Module type

Frame
size

ACS800-104-0003-3
ACS800-104-0004-3
ACS800-104-0005-3
ACS800-104-0006-3
ACS800-104-0009-3
ACS800-104-0011-3
ACS800-104-0016-3
ACS800-104-0020-3
ACS800-104-0025-3
ACS800-104-0030-3
ACS800-104-0040-3
ACS800-104-0050-3
ACS800-104-0060-3
ACS800-104-0100-3
ACS800-104-0120-3
ACS800-104-0170-3
ACS800-104-0210-3
ACS800-104-0260-3
ACS800-104-0320-3
ACS800-104-0390-3
ACS800-104-0510-3
ACS800-104-0770-3
ACS800-104-1030-3
ACS800-104-1540-3
ACS800-104-2050-3

R2i
R2i
R2i
R2i
R2i
R3i
R3i
R3i
R4i
R4i
R5i
R5i
R5i
R7i
R7i
R8i
R8i
R8i
R8i
R8i
R8i
2xR8i
2xR8i
3xR8i
4xR8i

Dimensions:
Frame
size
R2i
R3i
R4i
R5i
R7i1)
R8i
2xR8i
3xR8i
4xR8i

Height

Width

Depth

Weight

mm
401
466
525
673
744
1397
1397
1397
1397

mm
165
173
240
265
228
235
2452)
2452)
2452)

mm
1933)
2323)
2523)
2763)
367
596
596
596
596

kg
9
12
15
23
37
150
300
450
600

Noise
level
dB(A)
62
62
62
65
64
72
74
76
76

Air
flow
m3/h
35
69
103
168
480
1280
2560
3840
5120

Type
RDCU control unit *)

Height
mm
282

Width
mm
126

Depth
mm
41

*) Delivered with every unit.

Nominal Ratings:
Icont.max: rated current available continuously without overloadability at 40C.
Imax: maximum output current. Available for 10 s at start, otherwise as long as
allowed by drive temperature.

) Dimensions do not include cooling fan.


) Single module only.
3
) The depth is without without control panels and options.
2

Typical Ratings:
No-overload use
Pcont.max: typical motor power in no-overload use.
Light-overload use
IN: continuous current allowing 110% IN for 1min/ 5 min at 40C.
PN: typical motor power in light-overload use.
Heavy-duty use
Ihd: continuous current allowing 150% I hd for 1min/ 5 min at 40C.
Phd: typical motor power in heavy-duty use.
The current ratings are the same regardless of the supply voltage within one
voltage range.
The ratings apply in 40C ambient temperature.
In lower temperatures the ratings are higher (except Imax).
The rated current of the ACS800 must be higher than or equal to the rated motor
current to achieve the rated motor power given in the table.

18

3AFE 68248531 REV A EN 31.3.2004

Multidrive modules ratings, types and voltages


Supply module, UN= 400 V
ACS800

X04

No-overload
Nominal ratings
use
Pcont. max
Icont. max Icont. max
Imax
kW (DC)
A (AC) A (DC) A (DC)
UN = 400 V (Range 380 - 415 V)
IGBT supply module (ISU)
80
112
136
186
105
147
178
244
127
178
216
295
202
284
344
471
269
378
458
627
336
473
573
784
448
630
764
1046
672
945
1146
1568
879
1235
1497
2049
1304
1833
2223
3042
1722
2419
2933
4015
6-pulse diode (DSU)
183
286
350
462
262
408
500
700
367
571
700
924
524
816
1000
1400
733
1143
1400
1848
974
1518
1860
2604
1461
2278
2790
3906
1949
3037
3720
5208
2436
3796
4650
6510
6-pulse regenerative (TSU)
639
981
1202
1947
1053
1617
1980
3208
1595
2449
3000
4860
1861
2858
3500
5670
12-pulse diode (DSU)
367
571
700
924
524
816
1000
1400
733
1143
1400
1848
974
1518
1860
2604
1461
2278
2790
3906
1949
3037
3720
5208
2436
3796
4650
6510

0003

XXXX

SN

Light-overload
use
PN
IN

Heavy-duty
use
Phd
Ihd

81
106
128
204
272
340
453
679
888
1318
1739

77
100
122
194
258
323
430
646
844
1252
1653

130
171
207
331
440
550
733
1100
1437
2134
2816

60
78
95
151
201
252
335
503
657
976
1288

102
133
161
258
343
429
571
857
1120
1662
2194

2.1
3
3.6
5.9
8
10.3
14.6
20.5
28.3
41.7
54.8

ACS800-104-0070-3 R6i + ISU_LCL_5R7


ACS800-104-0100-3 R7i + ISU_LCL_5R7
ACS800-104-0120-3 R7i + ISU_LCL_5R7
ACS800-104-0260-3
R8i + ALCL-12-5
ACS800-104-0320-3
R8i + ALCL-13-5
ACS800-104-0390-3
R8i + ALCL-14-5
ACS800-104-0510-3
R8i + ALCL-15-5
ACS800-104-0770-3 2xR8i + ALCL-24-5
ACS800-104-1030-3 2xR8i + ALCL-25-5
ACS800-104-1540-3 3xR8i + 2xALCL-24-5
ACS800-104-2050-3 4xR8i + 2xALCL-25-5

198
283
396
566
792
1052
1578
2104
2630

175
251
351
503
702
938
1406
1875
2344

335
480
670
960
1340
1790
2685
3580
4475

147
210
293
419
587
780
1168
1561
1949

280
400
560
800
1120
1490
2230
2980
3720

1.5
2.4
3.8
5
7.6
10
15
20
25

ACS800-304-0320-7
ACS800-304-0450-7
ACS800-704-0640-7
ACS800-704-0910-7
ACS800-704-1370-7
ACS800-704-1810-7
ACS800-704-2720-7
ACS800-704-3630-7
ACS800-704-4540-7

D3
D3
D4
D4
2xD4
2xD4
3xD4
4xD4
5xD4

680
1120
1697
1980

604
996
1509
1760

1154
1901
2880
3360

378
622
943
1100

721
1188
1800
2100

6.3
10.2
16.5
20.8

ACS800-404-0680-3
ACS800-404-1120-3
ACS800-404-1700-3
ACS800-404-2100-3

2xB4 + choke
2xB4 + choke
2xB5 + choke
2xB5 + choke

396
566
792
1052
1578
2104
2630

351
503
702
938
1406
1875
2344

670
960
1340
1790
2685
3580
4475

293
419
587
780
1168
1561
1949

560
800
1120
1490
2230
2980
3720

3.8
5
7.6
10
15
20
25

ACS800-704-0640-7
ACS800-704-0910-7
ACS800-704-1370-7
ACS800-704-1810-7
ACS800-704-2720-7
ACS800-704-3630-7
ACS800-704-4540-7

D4
D4
2xD4
2xD4
3xD4
4xD4
5xD4

Heat
dissipation
kVA kW (DC) A (DC) kW (DC) A (DC)
kW

Module type

Nominal Ratings:
Icont.max: rated current
available continuously
without overloadability at
40C.

Frame
size

Imax: maximum output


current.
Typical Ratings:
No-overload use
Pcont.max: power in nooverload use.
Light-overload use
IN: continuous current
allowing 110% IN for 1min/
5 min at 40C.
PN: power in lightoverload use.
Heavy-duty use
Ihd: continuous current
allowing 150% Ihd for 1min/
5 min at 40C.
Phd: power in heavy-duty
use.
The current ratings are the
same regardless of the
supply voltage within one
voltage range.
The ratings apply in 40C
ambient temperature. In
lower temperatures the
ratings are higher (except
Imax).

Dimensions:
Frame
size

Height

Width

Depth

mm
mm
mm
IGBT supply unit (ISU)
1)
R6i
744
228
367
744
228
367
R7i1)
R8i
1397
245
596
2xR8i
1397
2452)
596
3xR8i
1397
2452)
596
4xR8i
1397
2452)
596
LCL-filter for IGBT supply unit (ISU)
ISU_LCL_XR7
810
304
292
ALCL-1X-X
1397
240
499
ALCL-2X-X
1397
240
573
6-pulse diode (DSU)
D3
1480
234
4003)
D4
1480
234
4003)
2XD4
1480
2342)
4003)
3XD4
1480
2342)
4003)
4XD4
1480
2342)
4003)
5XD4
1480
2342)
4003)

Weight
kg

Noise
level
dB(A)
4)

Air
flow
m3/h

37
37
150
300
450
600

65
654)
724)
744)
764)
764)

480
480
1280
2560
7680
5120

72
180
305

480
400
1280

130
180
360
540
720
900

65
65
67
68
69
70

720
720
1440
2160
2880
3600

Frame
size

Height

Width

Depth

Weight

mm
mm
mm
kg
6-pulse regenerative (TSU)
2)
2XB4
1808
340
430
1102)
2XB5
1808
4202)
430
1502)
DC chokes for 6-pulse regenerative (TSU)
choke B4
771
348
449
110
choke B5
991
348
449
150
12-pulse diode (DSU)
D4
1480
234
4003)
180
2XD4
1480
2342)
4003)
360
3XD4
1480
2342)
4003)
540
4XD4
1480
2342)
4003)
720
5XD4
1480
2342)
4003)
900

Noise
level
dB(A)

Air
flow
m3/h

725)
755)

2000
3400

600
700

65
67
68
69
70

720
1440
2160
2880
3600

) R6i and R7i dimensions do not include cooling fan.


) Single module only.
3
) Cable connections need additional space (about 200 mm)
behind the module.
4
) Supply modules + filters.
5
) Supply modules + choke.
2

3AFE 68248531 REV A EN 31.3.2004

19

Multidrive modules ratings, types and voltages


Drive module, UN= 500 V
ACS800

X04

No-overload
Nominal
use
ratings
Pcont. max
Icont. max
Imax

0003

Light-overload
use
PN
IN

kW
A
A
kW
UN = 500 V (Range 380 - 500 V)
2.2
4.9
7
2.2
3
6.2
8
3.0
4
8.1
11
4.0
5.5
11
14
5.5
7.5
13
18
7.5
11
19
24
11
15
25
32
15
19
34
46
18.5
22
42
62
22
30
48
72
30
37
65
86
37
45
79
112
45
55
96
138
55
75
112
168
75
90
135
224
90
110
164
270
110
160
250
363
160
200
315
457
200
250
365
530
250
315
455
660
315
355
525
762
355
500
700
1016
450
710
1050
1524
710
900
1372
1991
900
1400
2037
2956
1400
2000
2688
3901
1800

Heavy-duty
use
Phd
Ihd

kW

Heat
dissipation
kW

4.5
5.6
7.7
10
12
18
23
31
39
44
61
75
88
108
130
157
240
302
350
437
504
672
1008
1317
1956
2580

1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
355
500
710
1120
1400

3.4
4.2
5.6
7.5
9.2
13
18
23
32
36
50
60
69
84
112
135
187
236
273
340
393
524
785
1026
1524
2011

0.1
0.1
0.2
0.2
0.3
0.3
0.4
0.5
0.6
0.8
1.0
1.2
1.4
1.5
1.8
2.1
2.5
3.3
3.9
4.7
5.7
7.7
11.3
14.9
22.0
28.9

XXXX

Module type

Frame
size

ACS800-104-0004-5
ACS800-104-0005-5
ACS800-104-0006-5
ACS800-104-0009-5
ACS800-104-0011-5
ACS800-104-0016-5
ACS800-104-0020-5
ACS800-104-0025-5
ACS800-104-0030-5
ACS800-104-0040-5
ACS800-104-0050-5
ACS800-104-0060-5
ACS800-104-0070-5
ACS800-104-0100-5
ACS800-104-0120-5
ACS800-104-0140-5
ACS800-104-0210-5
ACS800-104-0260-5
ACS800-104-0320-5
ACS800-104-0400-5
ACS800-104-0460-5
ACS800-104-0610-5
ACS800-104-0910-5
ACS800-104-1210-5
ACS800-104-1820-5
ACS800-104-2430-5

R2i
R2i
R2i
R2i
R2i
R3i
R3i
R3i
R4i
R4i
R5i
R5i
R5i
R6i
R7i
R7i
R8i
R8i
R8i
R8i
R8i
R8i
2xR8i
2xR8i
3xR8i
4xR8i

Dimensions:
Frame Height
size
mm
R2i
401
R3i
466
R4i
525
R5i
673
744
R6i1)
744
R7i1)
R8i
1397
2xR8i
1397
3xR8i
1397
4xR8i
1397

Width

Depth

Weight

mm
165
173
240
265
228
228
235
2452)
2452)
2452)

mm
1933)
2323)
2523)
2763)
367
367
596
596
596
596

kg
9
12
15
23
37
37
150
300
450
600

Noise
level
dB(A)
62
62
62
65
64
64
72
74
76
76

Air
flow
m3/h
35
69
103
168
480
480
1280
2560
3840
5120

) Dimensions do not include cooling fan.


2
) Single module only.
3
) The depth is without without control panels and options.

Type
RDCU control unit *)

Height
mm
282

Width
mm
126

Depth
mm
41

*) Delivered with every unit.


Nominal Ratings:
I cont.max: rated current available continuously without overloadability at 40C.
I max: maximum output current. Available for 10 s at start, otherwise as long as
allowed by drive temperature.
Typical Ratings:
No-overload use
Pcont.max: typical motor power in no-overload use.
Light-overload use
I N: continuous current allowing 110% IN for 1min/ 5 min at 40C.
PN: typical motor power in light-overload use.
Heavy-duty use
I hd: continuous current allowing 150% Ihd for 1min/ 5 min at 40C.
Phd: typical motor power in heavy-duty use.
The current ratings are the same regardless of the supply voltage within one
voltage range.
The ratings apply in 40C ambient temperature.
In lower temperatures the ratings are higher (except I max).
The rated current of the ACS800 must be higher than or equal to the rated motor
current to achieve the rated motor power given in the table.

20

3AFE 68248531 REV A EN 31.3.2004

Multidrive modules ratings, types and voltages


Supply module, UN= 500 V
ACS800

X04

No-overload
Nominal ratings
use
Icont. max Icont. max
Imax
Pcont. max
kW (DC)
A (AC) A (DC) A (DC)
UN = 500 V (Range 380 - 500 V)
IGBT supply module (ISU)
96
112
136
197
116
135
164
238
141
164
199
289
231
270
327
475
309
360
436
633
386
450
546
792
514
600
727
1056
772
900
1091
1584
1008
1176
1426
2069
1497
1746
2117
3072
1975
2304
2794
4054
6-pulse diode (DSU)
229
286
350
462
327
408
500
700
458
571
700
924
655
816
1000
1400
917
1143
1400
1848
1218
1518
1860
2604
1827
2278
2790
3906
2436
3037
3720
5208
3045
3796
4650
6510
6-pulse regenerative (TSU)
792
981
1202
1947
1304
1617
1980
3208
1976
2449
3000
4860
2305
2858
3500
5670
12-pulse diode (DSU)
458
571
700
924
655
816
1000
1400
917
1143
1400
1848
1218
1518
1860
2604
1827
2278
2790
3906
2436
3037
3720
5208
3045
3796
4650
6510

0003

SN

Light-overload
use
PN
IN

kVA

XXXX

Heavy-duty
use
Phd
Ihd

Heat
dissipation
kW (DC) A (DC) kW (DC) A (DC)
kW

Module type

Nominal Ratings:
Icont.max: rated current
available continuously
without overloadability at
40C.

Frame
size

97
117
142
234
312
390
520
779
1018
1512
1995

92
111
135
222
296
370
494
741
968
1437
1896

130
157
191
314
419
524
698
1048
1369
2032
2682

72
87
105
173
231
289
385
577
754
1120
1478

102
122
149
245
327
408
544
816
1067
1584
2090

3
3.6
4.2
6.2
8.4
10.6
14.9
21.2
28.9
42.7
56.1

ACS800-104-0100-5 R6i + ISU_LCL_5R7


ACS800-104-0120-5 R7i + ISU_LCL_5R7
ACS800-104-0140-5 R7i + ISU_LCL_5R7
ACS800-104-0320-5
R8i + ALCL-12-5
ACS800-104-0400-5
R8i + ALCL-13-5
ACS800-104-0460-5
R8i + ALCL-14-5
ACS800-104-0610-5
R8i + ALCL-15-5
ACS800-104-0910-5 2xR8i + ALCL-24-5
ACS800-104-1210-5 2xR8i + ALCL-25-5
ACS800-104-1820-5 3xR8i + 2xALCL-24-5
ACS800-104-2430-5 4xR8i + 2xALCL-25-5

247
353
495
707
990
1315
1972
2630
3287

219
314
439
629
877
1172
1758
2344
2930

335
480
670
960
1340
1790
2685
3580
4475

183
262
367
524
733
976
1460
1951
2436

280
400
560
800
1120
1490
2230
2980
3720

1.5
2.4
3.8
5
7.6
10
15
20
25

ACS800-304-0320-7
ACS800-304-0450-7
ACS800-704-0640-7
ACS800-704-0910-7
ACS800-704-1370-7
ACS800-704-1810-7
ACS800-704-2720-7
ACS800-704-3630-7
ACS800-704-4540-7

D3
D3
D4
D4
2xD4
2xD4
3xD4
4xD4
5xD4

850
1400
2120
2475

604
996
1509
1760

1154
1901
2880
3360

472
778
1179
1375

721
1188
1800
2100

6.3
10.2
16.5
20.8

ACS800-404-0850-5
ACS800-404-1400-5
ACS800-404-2120-5
ACS800-404-2600-5

2xB4 + choke
2xB4 + choke
2xB5 + choke
2xB5 + choke

495
707
990
1315
1972
2630
3287

439
629
877
1172
1758
2344
2930

670
960
1340
1790
2685
3580
4475

367
524
733
976
1460
1951
2436

560
800
1120
1490
2230
2980
3720

3.8
5
7.6
10
15
20
25

ACS800-704-0640-7
ACS800-704-0910-7
ACS800-704-1370-7
ACS800-704-1810-7
ACS800-704-2720-7
ACS800-704-3630-7
ACS800-704-4540-7

D4
D4
2xD4
2xD4
3xD4
4xD4
5xD4

Imax: maximum output


current.
Typical Ratings:
No-overload use
Pcont.max: power in nooverload use.
Light-overload use
IN: continuous current
allowing 110% IN for 1min/
5 min at 40C.
PN: power in lightoverload use.
Heavy-duty use
Ihd : continuous current
allowing 150% Ihd for 1min/
5 min at 40C.
Phd: power in heavy-duty
use.
The current ratings are the
same regardless of the
supply voltage within one
voltage range.
The ratings apply in 40C
ambient temperature. In
lower temperatures the
ratings are higher (except
Imax).

Dimensions:
Frame
size

Height

Width

Depth

mm
mm
mm
IGBT supply unit (ISU)
R6i1)
744
228
367
R7i1)
744
228
367
R8i
1397
245
596
2xR8i
1397
2452)
596
3xR8i
1397
2452)
596
596
4xR8i
1397
2452)
LCL-filter for IGBT supply unit (ISU)
ISU_LCL_XR7
810
304
292
ALCL-1X-X
1397
240
499
ALCL-2X-X
1397
240
573
6-pulse diode (DSU)
D3
1480
234
4003)
D4
1480
234
4003)
2XD4
1480
2342)
4003)
3XD4
1480
2342)
4003)
4XD4
1480
2342)
4003)
5XD4
1480
2342)
4003)

Weight
kg

Noise
level
dB(A)
4)

Air
flow
m3/h

37
37
150
300
450
600

65
654)
724)
744)
764)
764)

480
480
1280
2560
7680
5120

72
180
305

480
400
1280

130
180
360
540
720
900

65
65
67
68
69
70

720
720
1440
2160
2880
3600

Frame
size

Height

Width

Depth

Weight

mm
mm
mm
kg
6-pulse regenerative (TSU)
2)
2XB4
1808
340
430
1102)
2XB5
1808
4202)
430
1502)
DC chokes for 6-pulse regenerative (TSU)
choke B4
771
348
449
110
choke B5
991
348
449
150
12-pulse diode (DSU)
180
D4
1480
234
4003)
2XD4
1480
2342)
4003)
360
3XD4
1480
2342)
4003)
540
4XD4
1480
2342)
4003)
720
4003)
900
5XD4
1480
2342)

Noise
level
dB(A)

Air
flow
m3/h

725)
755)

2000
3400

600
700

65
67
68
69
70

720
1440
2160
2880
3600

) R6i, R7i dimensions do not include cooling fan.


) Single module only.
) Cable connections need additional space (about 200 mm)
behind the module.
4
) Supply modules + filters.
5
) Supply modules + choke.
2
3

3AFE 68248531 REV A EN 31.3.2004

21

Multidrive modules ratings, types and voltages


Drive module, UN= 690 V
ACS800

X04

No-overload
Nominal
use
ratings
Pcont. max
Icont. max
Imax

0003

Light-overload
use
PN
IN

kW
A
A
kW
UN = 690 V (Range 525 - 690 V)
11
13
14
7.5
15
17
19
11
18.5
22
28
15
22
25
38
18.5
30
33
44
22
30
36
54
30
45
51
68
37
55
57
84
45
55
65
104
55
75
88
130
75
90
105
176
90
160
170
254
160
200
215
322
200
250
289
432
250
315
336
503
315
355
382
571
355
450
486
727
450
710
729
1091
710
900
953
1425
900
1400
1414
2116
1400
1800
1866
2792
1800

Heavy-duty
use
Phd
Ihd

kW

Heat
dissipation
kW

12
16
21
24
32
35
49
55
62
84
101
163
206
277
323
367
467
700
914
1358
1792

5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
132
160
200
250
315
500
630
900
1400

8.5
11
15
19
22
27
34
42
52
65
88
127
161
216
251
286
364
545
713
1058
1396

0.3
0.3
0.4
0.5
0.6
0.7
0.8
1.0
1.1
1.5
1.8
3.3
4.0
4.6
5.2
6.8
7.4
12.9
14.4
21.3
28.1

XXXX

Module type

Frame
size

ACS800-104-0011-7
ACS800-104-0016-7
ACS800-104-0020-7
ACS800-104-0025-7
ACS800-104-0030-7
ACS800-104-0040-7
ACS800-104-0050-7
ACS800-104-0060-7
ACS800-104-0070-7
ACS800-104-0100-7
ACS800-104-0120-7
ACS800-104-0210-7
ACS800-104-0260-7
ACS800-104-0320-7
ACS800-104-0400-7
ACS800-104-0440-7
ACS800-104-0580-7
ACS800-104-0870-7
ACS800-104-1160-7
ACS800-104-1740-7
ACS800-104-2320-7

R4i
R4i
R4i
R4i
R4i
R4i
R5i
R5i
R6i
R7i
R7i
R8i
R8i
R8i
R8i
R8i
R8i
2xR8i
2xR8i
3xR8i
4xR8i

Dimensions:
Frame Height
size
mm
R2i
401
R3i
466
R4i
525
R5i
673
R6i1)
744
744
R7i1)
R8i
1397
2xR8i
1397
3xR8i
1397
4xR8i
1397

Width

Depth

Weight

mm
165
173
240
265
228
228
235
2452)
2452)
2452)

mm
1933)
2323)
2523)
2763)
367
367
596
596
596
596

kg
9
12
15
23
37
37
150
300
450
600

Noise
level
dB(A)
62
62
62
65
64
64
72
74
76
76

Air
flow
m3/h
35
69
103
168
480
480
1280
2560
3840
5120

) Dimensions do not include cooling fan.


2
) Single module only.
3
) The depth is without without control panels and options.

Type
RDCU control unit *)

Height
mm
282

Width
mm
126

Depth
mm
41

*) Delivered with every unit.


Nominal Ratings:
I cont.max: rated current available continuously without overloadability at 40C.
I max: maximum output current. Available for 10 s at start, otherwise as long as
allowed by drive temperature.
Typical Ratings:
No-overload use
Pcont.max: typical motor power in no-overload use.
Light-overload use
I N: continuous current allowing 110% IN for 1min/ 5 min at 40C.
PN: typical motor power in light-overload use.
Heavy-duty use
I hd: continuous current allowing 150% Ihd for 1min/ 5 min at 40C.
Phd: typical motor power in heavy-duty use.
The current ratings are the same regardless of the supply voltage within one
voltage range.
The ratings apply in 40C ambient temperature.
In lower temperatures the ratings are higher (except I max).
The rated current of the ACS800 must be higher than or equal to the rated motor
current to achieve the rated motor power given in the table.

22

3AFE 68248531 REV A EN 31.3.2004

Multidrive modules ratings, types and voltages


Supply module, UN= 690 V
ACS800

X04

No-overload
Nominal ratings
use
Icont. max Icont. max
Imax
Pcont. max
kW (DC)
A (AC) A (DC) A (DC)
UN = 690 V (Range 525 - 690 V)
IGBT supply module (ISU)
77
65
79
118
104
88
107
160
124
105
127
190
213
180
218
327
296
250
303
453
355
300
364
544
473
400
485
726
710
600
727
1088
928
784
951
1422
1377
1164
1411
2111
1817
1536
1862
2786
6-pulse diode (DSU)
316
286
350
462
452
408
500
700
632
571
700
924
904
816
1000
1400
1265
1143
1400
1848
1681
1518
1860
2604
2521
2278
2790
3906
3361
3037
3720
5208
4202
3796
4650
6510
6-pulse regenerative (TSU)
784
711
871
1411
1292
1171
1435
2325
2399
2176
2664
4316
3152
2858
3500
5670
12-pulse diode (DSU)
632
571
700
924
904
816
1000
1400
1265
1143
1400
1848
1681
1518
1860
2604
2521
2278
2790
3906
3361
3037
3720
5208
4202
3796
4650
6510

0003

SN

Light-overload
use
PN
IN

XXXX

Heavy-duty
use
Phd
Ihd

Heat
dissipation
kVA kW (DC) A (DC) kW (DC) A (DC)
kW

Module type

Nominal Ratings:
Icont.max: rated current
available continuously
without overloadability at
40C.

Frame
size

78
105
125
215
299
359
478
717
937
1391
1836

74
100
119
204
284
341
454
682
890
1322
1745

76
102
122
210
291
349
466
698
913
1355
1788

58
78
93
159
221
266
354
531
694
1030
1359

59
80
95
163
227
272
363
544
711
1056
1393

2.1
3
3.6
8.3
9.4
13.3
14.6
26.6
28.5
42.3
55.7

ACS800-104-0070-7 R6i + ISU_LCL_6R7


ACS800-104-0100-7 R7i + ISU_LCL_6R7
ACS800-104-0120-7 R7i + ISU_LCL_6R7
ACS800-104-0260-7
R8i + ALCL-12-7
ACS800-104-0400-7
R8i + ALCL-13-7
ACS800-104-0440-7
R8i + ALCL-14-7
ACS800-104-0560-7
R8i + ALCL-15-7
ACS800-104-0870-7 2xR8i + ALCL-24-7
ACS800-104-1160-7 2xR8i + ALCL-25-7
ACS800-104-1740-7 3xR8i + 2xALCL-24-5
ACS800-104-2320-7 4xR8i + 2xALCL-25-7

341
488
683
976
1366
1815
2722
3629
4537

303
434
605
867
1211
1617
2426
3235
4043

335
480
670
960
1340
1790
2685
3580
4475

253
361
506
723
1012
1346
2015
2693
3361

280
400
560
800
1120
1490
2230
2980
3720

1.5
2.4
3.8
5
7.6
10
15
20
25

ACS800-304-0320-7
ACS800-304-0450-7
ACS800-704-0640-7
ACS800-704-0910-7
ACS800-704-1370-7
ACS800-704-1810-7
ACS800-704-2720-7
ACS800-704-3630-7
ACS800-704-4540-7

D3
D3
D4
D4
2xD4
2xD4
3xD4
4xD4
5xD4

850
1400
2600
3415

438
722
1340
1760

836
1378
2557
3360

472
778
1444
1897

523
861
1598
2100

6.3
10.2
16.5
20.8

ACS800-404-0850-7
ACS800-404-1400-7
ACS800-404-2600-7
ACS800-404-3600-7

2xB4 + choke
2xB4 + choke
2xB5 + choke
2xB5 + choke

683
976
1366
1815
2722
3629
4537

605
867
1211
1617
2426
3235
4043

670
960
1340
1790
2685
3580
4475

506
723
1012
1346
2015
2693
3361

560
800
1120
1490
2230
2980
3720

3.8
5
7.6
10
15
20
25

ACS800-704-0640-7
ACS800-704-0910-7
ACS800-704-1370-7
ACS800-704-1810-7
ACS800-704-2720-7
ACS800-704-3630-7
ACS800-704-4540-7

D4
D4
2xD4
2xD4
3xD4
4xD4
5xD4

Imax: maximum output


current.
Typical Ratings:
No-overload use
Pcont.max: power in nooverload use.
Light-overload use
IN: continuous current
allowing 110% IN for 1min/
5 min at 40C.
PN: power in lightoverload use.
Heavy-duty use
Ihd : continuous current
allowing 150% Ihd for 1min/
5 min at 40C.
Phd: power in heavy-duty
use.
The current ratings are the
same regardless of the
supply voltage within one
voltage range.
The ratings apply in 40C
ambient temperature. In
lower temperatures the
ratings are higher (except
Imax).

Dimensions:
Frame
size

Height

Width

Depth

mm
mm
mm
IGBT supply unit (ISU)
R6i1)
744
228
367
R7i1)
744
228
367
R8i
1397
245
596
2xR8i
1397
2452)
596
3xR8i
1397
2452)
596
596
4xR8i
1397
2452)
LCL-filter for IGBT supply unit (ISU)
ISU_LCL_XR7
810
304
292
ALCL-1X-X
1397
240
499
ALCL-2X-X
1397
240
573
6-pulse diode (DSU)
D3
1480
234
4003)
D4
1480
234
4003)
2XD4
1480
2342)
4003)
3XD4
1480
2342)
4003)
4XD4
1480
2342)
4003)
5XD4
1480
2342)
4003)

Weight
kg

Noise
level
dB(A)
4)

Air
flow
m3/h

37
37
150
300
450
600

65
654)
724)
744)
764)
764)

480
480
1280
2560
7680
5120

72
180
305

480
400
1280

130
180
360
540
720
900

65
65
67
68
69
70

720
720
1440
2160
2880
3600

Frame
size

Height

Width

Depth

Weight

mm
mm
mm
kg
6-pulse regenerative (TSU)
2)
2XB4
1808
340
430
1102)
2XB5
1808
4202)
430
1502)
DC chokes for 6-pulse regenerative (TSU)
choke B4
771
348
449
110
choke B5
991
348
449
150
12-pulse diode (DSU)
180
D4
1480
234
4003)
2XD4
1480
2342)
4003)
360
3XD4
1480
2342)
4003)
540
4XD4
1480
2342)
4003)
720
4003)
900
5XD4
1480
2342)

Noise
level
dB(A)

Air
flow
m3/h

725)
755)

2000
3400

600
700

65
67
68
69
70

720
1440
2160
2880
3600

) R6i, R7i dimensions do not include cooling fan.


) Single module only.
) Cable connections need additional space (about 200 mm)
behind the module.
4
) Supply modules + filters.
5
) Supply modules + choke.
2
3

3AFE 68248531 REV A EN 31.3.2004

23

Multidrive modules ratings, types and voltages


Braking unit

Nominal ratings
Module type

Resistor type

UN = 400 V (Range 380 - 500 V)


NBRA658
NBRA659
2 x NBRA659
3 x NBRA659
4 x NBRA659
5 x NBRA659
6 x NBRA659
NBRA658
2 x SAFUR210F575
NBRA659
2 x SAFUR180F460
2 x NBRA6591 2 x (2 x SAFUR180F460)
3 x NBRA659 3 x (2 x SAFUR180F460)
4 x NBRA659 4 x (2 x SAFUR180F460)
5 x NBRA659 5 x (2 x SAFUR180F460)
6 x NBRA659 6 x (2 x SAFUR180F460)
UN = 500 V (Range 380 - 415 V)
NBRA658
NBRA659
2 x NBRA659
3 x NBRA659
4 x NBRA659
5 x NBRA659
6 x NBRA659
NBRA658
2 x SAFUR125F500
NBRA659
2 x SAFUR200F500
2 x NBRA659 2 x (2 x SAFUR200F500)
3 x NBRA659 3 x (2 x SAFUR200F500)
4 x NBRA659 4 x (2 x SAFUR200F500)
5 x NBRA659 5 x (2 x SAFUR200F500)
6 x NBRA659 6 x (2 x SAFUR200F500)
UN = 690 V (Range 525 - 690 V)
NBRA669
2 x NBRA669
3 x NBRA669
4 x NBRA669
5 x NBRA669
6 x NBRA669
NBRA669
2 x SAFUR200F500
2 x NBRA669 2 x (2 x SAFUR200F500)
3 x NBRA669 3 x (2 x SAFUR200F500)
4 x NBRA669 4 x (2 x SAFUR200F500)
5 x NBRA6691 5 x (2 x SAFUR200F500)
6 x NBRA669 6 x (2 x SAFUR200F500)

Pbr.max

Imax

Irms.

Pcont.

Duty cycle
(1min/5min)
Pbr.
Irms

kW

ohm

kW

kW

kW

dB(A)

m3/h

230
353
706
1058
1411
1764
2117
230
353
706
1058
1411
1764
2117

1.7
1.2
0.6
0.4
0.3
0.24
0.2
1.7
1.2
0.6
0.4
0.3
0.24
0.2

384
545
1090
1635
2180
2725
3270
384
545
1090
1635
2180
2725
3270

109
149
298
447
596
745
894
65
84
168
252
336
420
504

70
96
192
288
384
480
576
42
54
108
162
216
270
324

230
303
606
909
1212
1515
1818
130
167
333
500
667
833
1000

355
468
936
1404
1872
2340
2808
200
257
514
771
1028
1285
1542

230
353
706
1059
1412
1765
2118
224
287
575
862
1150
1437
1724

355
545
1090
1635
2180
2725
3270
346
444
888
1332
1776
2220
2664

64
64
67
68
69
70
71
66
66
69
70
71
72
73

660
660
1320
1980
2640
3300
3960
2500
2500
5000
7500
10000
12500
15000

268
403
806
1208
1611
2014
2417
268
403
806
1208
1611
2014
2417

2.15
1.43
0.72
0.48
0.36
0.29
0.24
2.00
1.35
0.68
0.45
0.34
0.27
0.23

380
571
1142
1713
2284
2855
3426
408
605
1210
1815
2420
3025
3630

101
136
272
408
544
680
816
45
67
134
201
268
335
402

81
109
218
327
436
545
654
36
54
108
162
216
270
324

268
317
634
951
1268
1585
1902
111
167
333
500
667
833
1000

331
391
782
1173
1564
1955
2346
137
206
412
618
824
1030
1236

268
403
806
1209
1612
2015
2418
192
287
575
862
1150
1437
1724

331
498
996
1494
1992
2490
2988
237
355
710
1065
1420
1775
2130

64
64
67
68
69
70
71
66
66
69
70
71
72
73

660
660
1320
1980
2640
3300
3960
2500
2500
5000
7500
10000
12500
15000

404
807
1211
1615
2019
2422
404
807
1211
1615
2019
2422

2.72
1.36
0.91
0.68
0.54
0.45
1.35
0.68
0.45
0.34
0.27
0.23

414
828
1242
1656
2070
2484
835
1670
2505
3340
4175
5010

107
214
321
428
535
642
97
194
291
388
485
582

119
238
357
476
595
714
54
108
162
216
270
324

298
596
894
1192
1490
1788
167
333
500
667
833
2000

267
534
801
1068
1335
1602
149
298
447
596
745
894

404
808
1212
1616
2020
2424
287
575
862
1150
1437
1724

361
722
1083
1444
1805
2166
257
514
771
1028
1285
1542

64
67
68
69
70
71
66
69
70
71
72
73

660
660
1320
1980
2640
3300
2500
5000
7500
10000
12500
15000

Pbr,max = Maximum braking power of the NBRA-6xx chopper and SAFUR resistor
combination.
The chopper will withstand this braking power for one minute every
ten minutes.

Frame size

Duty cycle
(10s/60s)
Pbr.
Irms

Noise

Air flow

Height

Brake Chopper Modules


NBRA658
584
NBRA659
584
SAFUR180F460
1320
SAFUR125F500
1320
SAFUR200F500
1320
SAFUR210F575
1320

Note: The braking energy transmitted to the resistor during any period shorter
than 400 seconds may not exceed Er.
The standard resistor therefore withstands continuous braking of Pbr,max typically
20 to 40 seconds (t = Er / Pbr,max).
1

) Single module only.

= Recommended brake resistor resistance. Also nominal resistance of


corresponding SAFUR resistor.

Imax

= Maximum peak current per chopper during braking. Current is


achieved with minimum resistor resistance.

Irms

= Corresponding rms current per chopper during load cycle.

Heat loss of brake chopper is 1 % of braking power.


Heat loss of section with brake resistors is the same as braking power.

24

3AFE 68248531 REV A EN 31.3.2004

Width

Depth

Weight

334
3341)
3001)
3001)
3001)
3001)

240
240
345
345
345
345

26
261)
321)
251)
301)
271)

Вам также может понравиться