DEVELOP LC METHOD
Calculation of key
PK parameters:
C 0 = Concentration at T 0
D = Dose
V = Volume of distribution
T 1/2 = Half life
Cmax
C0
PK profile.
and development.
also be needed.
more >>
4
UPLC/MS/MS
& -elution SPE
(pg/mL, 1 min)
ITY
UPLC/MS/MS
(25 pg/mL, 1 min)
IV
SIT
SE
High Sensitivity
MS/MS
(pg/mL, 5 min)
SPEED
GC/MS
(ng/mL, 30 min)
1970
HPLC
WISP (500 ng/mL,
HPLC-UV
25 min)
(10s g/mL, 40 min)
1980
HPLC-UV
HPLC-Fluorescence
& SPE
& SPE
(10 ng/mL,
(ng/mL, 25 min)
25 min)
1990
LC/MS/MS
& On-line SPE
(100 pg/mL, 10 min)
LC/MS/MS
(ng/mL, 5 min)
2000
(SPE) techniques.
PK and
bioanalysis
in drug
discovery
Full PK characterization in
the drug discovery phase
is not required; however,
in conjunction with in vitro
techniques, the ability
to quickly assess the
bioavailability of a compound
through bioanalysis gives
a good indication of
suitability for advancement
to development.
Phase IIb
Dose ranging studies are carried
out on patients to establish
effective doses for Phase II trials.
Analytical priorities include:
n High-sensitivity assays
n High-specificity assays
for drug compound and
metabolites
n Fast turnaround of samples
elimination half-life.
OVERVIE W
tool of choice for both selective and sensitive detection of compounds of interest in difficult matrices.
protection.
conforms to all the requirements laid out for a regulated environment has its own layers of challenges in addition to ensuring that
and effectively.
INTRODUC TION
Can sample be
separated
by chromatography?
Sample preparation
Chromatography
Can sample be
analyzed
by mass spectrometry?
No
CONSULT
EX PERT
Yes
DEV ELOP
MS/MS METHOD
CONSULT
EX PERT
Yes
No
No
DEV ELOP
LC METHOD
Can sufficient
sensitivity
be obtained?
No
Will sample
concentration
meet need?
DEV ELOP
SAMPLE PREPARATION
METHOD
Yes
Optimize methodology
for specificity,
sensitivity, and speed
Validate
the method
10
all the key factors involved with bioanalytical studies. For example:
more a series of iterative and interlinked steps that may often need
Since the method will ultimately be carried out using a real sample,
used to treat patients who are diabetic, obtaining plasma from these
ment of the LC, MS, or sample preparation step due to issues detected in
We will now provide an outline and rationale for each step discussed
so far that will also shed light on the iterative processes and how they
can be managed.
11
DISCUSSION
set of conditions.
necessary to determine:
n
sensitive MRM path for detection and quantitation. Using the infor-
Matrix effects
Liquid chromatography
can be determined.
Sample preparation
of the LC methodology.
Good practice here is to refer to knowledge gained from previous experiences, such as animal studies or in vitro experiments. If samples from
these studies are available, they should be injected onto the chromatog-
Incurred sample
reanalysis
13
The two most common biological samples that require analysis are:
Detection and
characterization
of metabolites
liquid extraction.
Protein precipitation only addresses the removal of proteins.
Phospholipids and other contaminants that remain in the matrix
may cause ion suppression or enhancement, which will lead to
14
15% variation
Matrix effects
By using either high or low pH with the Oasis sorbent, selectivity for
of analytes.
best sorbent has been selected the methodology can be optimized for
monitoring, will help monitor the status of the assay, allowing the
wash composition.
Method validation
All changes to the assay are filed and stored as part of the method
in order to remain compliant.
CONC LUSION
20% expected
15
16
R O B U S T M R M M S / M S M E T H O D D E V E L O P M E N T fo r B ioanalytical A ssays
INTRODUC TION
ionization, both positive and negative. This often means that the
m/z value (parent or daughter ion) that will offer the best
Ionization mode
Capillary voltage
Cone voltage
Source temperature
Collision energy
17
for ibuprofen.
and IntelliStart.
n
ing the source. Not only can the user readily establish the best
ESCi also clarifies the best m/z ion to monitor in the assay.
n
MODE OF IONIZATION
Positive or negative, APCI or ESI
DETERMINE MS ION
Parent ion or adduct
DISCUSSION
Development of an MRM method for ibuprofen
(UPLC) Technology.
18
Ex p erimental
Using IntelliStart and ESCi, the MRM method development process
was greatly simplified. The steps taken to develop the method and
complete the workflow in Figure 1 are detailed in Figure 2.
To begin the process, neat sample was introduced into the mass spectrometer by direct infusion. (Other common methods of introduction
are via a fast gradient elution off a column or a direct loop injection.)
Using ESCi for steps 1 and 2 of the optimization process allowed us
to determine which was the best ionization source for analysis of the
compound in less than one minute and three keystrokes.
The results from ESCi clearly illustrate that ibuprofen ionized in
both APCI and ESI negative modes; ESI negative yielded the best
sensitivity and was therefore chosen. This step in the optimization
process also told us that the molecular ion observed with the best
sensitivity was m/z 205, as shown in Figure 3.
STEP 1
Select ESCi to show ESI and APCI ionizations
and observed m/z
Figure 3. ESCi of ibuprofen.
STEP 2
Select most effective ionization mode
STEP 3
Input m/z value into IntelliStart
19
settings for the MRM method. The report also detailed the daughter
ion spectra along with cone voltage and collision energy values
(Figure 4).
LC conditions
LC system:
Column:
Column temp.:
40 C
Flow rate:
50 L/min
20
MS conditions
CONC LUSION
MS system:
mass spectrometer
Ionization mode:
ESI negative
for assays.
Capillary voltage:
3.8 KV
Cone volyage:
15 V
Desolvation temp.:
450 C
Desolvation gas:
900 L/Hr
Source temp.:
150 C
Acquisition mode:
Collision energy:
10 eV
Developing the MRM method for ibuprofen actually took an inexperienced user about 4 minutes. In this time, the best ion for monitoring
was observed and MS parameters were set up and entered in the
method for ibuprofen appropriate to a regulated environment.
References
Yu K, Di L, Kerns E, Li S, Alden P, and Plumb R. Rapid Communications in Mass
Spectrometry. 2007; 21 (6) 893-902.
Rainville P, Mather J, and Plumb R. Waters Application Note. 2008; 720002569en.
Morphet J and Hancock P. Waters Application Note. 2007; 720002329en.
21
22
OVERVIE W
Column choice
Accuracy
Precision
Specificity
Detection limit
Quantitation limit
Linearity
Range
Robustness
pH
Often the analyte of interest will be polar. Other compounds of
Organic modifier
Before going down the path towards developing a method, you need
development of a separation.
23
When all these aspects have been considered and optimized for
the analytes of interest, the assay can be checked to determine the
SELECT pH
Waters has outlined a simple yet effective and comprehensive strategy for optimizing a method for analysis of analytes in a complex
matrix such as blood, plasma, urine, or tissue.
Use of the ACQUITY UPLC System allows this process to take place
quickly and effectively. Screening runs can take place in as little
as two minutes. Automation for screening additional parameters
ASSESS INTERFERENCES
TEST IN MATRIX
CHECK SENSITIVITY
24
APPLICATION E X AMPLE
method development.
the primary circulating species. Since the 9-OH metabolite has the
Both the parent and the metabolite in this case have a pKa above 7.
analyte signal.
deliver the mobile phase to the column and the mass detector to
cannot be realized.
pH considerations
Column choice
We selected the ACQUITY UPLC BEH Column for this analysis. Its
high and low pHs, making it suitable for a wide range of analyses.
25
E X PERIMENTAL
LC system:
Column:
MeOH
ACN
the method.
Flow rate:
0.6 mL/min
Gradient:
Time (min)
%A
%B
0.0
98
2.0
98
that gives us the best starting point for peak shape, retention,
2.5
98
and selectivity.
2.6
98
3.0
98
low ph
high ph
1.42
2.86e6
2.86e6
1.35
1.06
meoh
1.11
1.54
1.25
0
0
0.50
1.00
1.50
2.00
2.50
0.50
2.00
2.50
2.86e6
0.98
0.88
1.50
1.04
2.86e6
aCn
1.00
0.84
1.26
0.95
0.50
1.00
1.50
2.00
2.50
0.50
1.00
time
Figure 2. Evaluating peak shape, resolution, and sensitivity in the pH screening results.
26
1.50
time
2.00
2.50
peak order:
1. 9-oh risperidone metabolite
2. risperidone
3. Clozapine (internal standard)
Injection volume:
5.0 L
Column temp.:
50 C
Sample temp.:
15 C
50:50 H2O/MeOH
95:5 H2O/MeOH
Injection mode:
Partial loop
Optimize gradient
MS system:
Ionization mode:
ESI positive
that the analytes do not elute until after the first minute of the
Capillary:
3.0 kV
Source temp.:
120 C
Desolvation temp.:
350 C
50 L/Hr
flow rate, column length, gradient slope, and profile. In this example,
30 msec
Screening results
the analytes eluted at 70% organic and elute our compounds earlier
while maintaining sensitivity and freedom from interferences.
Figure 2 shows results of the initial screening run. The peaks are
9-hydroxyrisperidone metabolite, risperidone, and the internal stan-
dard, clozapine. All the results are plotted on the same intensity scale.
50% organic. This shortened the gradient time (Figure 3) for a 50%
reduction in cycle time.
Select pH
From Figure 2, we could see enhanced sensitivity at high pH as well
as improved resolution of the metabolite (peak 1) from risperidone.
Consequently, we selected high pH. The next task was to select the
organic solvent. Note that each screen took only 3 minutes.
27
1.42
0.82
TIC
2.86e6
TIC
3.83e6
1.35
0.76
1.54
0.92
0.50
1.00
1.50
2.00
2.50
Time
Time
0.50
1.00
1.50
2.00
2.50
Figure 3. Starting at a higher organic percentage and shortening the gradient cut the cycle time in half.
Assess interferences
Having developed a method that is optimal for speed, sensitivity,
using the transition m/z 184 to 184. This confirms the presence
was optimized for the three analytes of interest (Figure 4). The
MRM transitions for the analytes confirmed their identity. The final
quantitation and confirm that they meet requirements for the assay.
shows that there was significant separation of the analytes from the
easily achieved.
28
CONC LUSION
Matrix effects < 5%
1.00e7
Risperidone
Clozapine
0.82
9-OH Risperidone
metabolite
0.76
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
1.30
1.40
Time
1.50
References
0.75
0.1 ng/mL
9-Hydroxy Risperidone
0.84
0.29
-4
96
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
1.08
0.90
1.00
1.10
1.20
1.30
0.81
96
1.40
1.50
Risperidone
0.04
-4
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
1.30
0.91
98
1.40
1.50
Clozapine
0.11
-2
0.10
0.85
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0.94
0.99
1.07
1.00
1.10
1.23
1.20
1.35
1.30
1.40
Time
1.50
29
30
INTRODUC TION
Matrix effects
elute late from a reversed-phase column and have the potential for
Poor sensitivity
Interfering peaks/cleanliness
Sample throughput
and sample variability and ensure compliance with the FDA guidance
spiked in to a blank matrix sample that has been carried thought the
31
Standard solution
(analyte(s))
100
4.64e4
0.20
0.40
0.60
1.08
0.80
%
0
1.00
%
0
Post-extracted
spiked sample
% Matrix effects = (
1.40
1.60
1.80
2.00
4.64e4
0.20
0.40
0.60
0.80
1.00
100
Spike standards
into extracted matrix
1.20
1.08
100
1.20
1.40
1.60
1.80
1.10
2.00
4.64e4
C. Standard in solution
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
Time
2.00
of concept for the Waters Oasis SPE 2x4 method to assess matrix
effects after cleanup of a complex sample.
Matrix effects can be measured and factored into results, but the
effects completely.
by SPE has meant a long and laborious process fraught with many
choices and development steps: the effort expended has not always
C. Standard in solution
in each sample.
automated scale.
32
APPLICATION E X AMPLE I
FOR BASES
pKa 2 to 10
use Oasis MCX
FOR ACIDS
pKa 2 to 8
Use Oasis MAX
Protocol 1
Prepare Sample
Prepare Sample
Condition/Equilibrate
Load Sample
Condition/Equilibrate
Load Sample
Wash:
2% Formic acid
Wash:
5% NH 4OH
first attempt.
Elute 1:
100% MeOH
Elute 2:
5% NH 4OH in 60:40 ACN/MeOH
BASES
Elute 1:
100% MeOH
Neutrals
STRONG
ACIDS
Elute 2:
5% HCOOH in 60:40 ACN/MeOH
STRONG
BASES
ACIDS
Figure 3. Oasis 2x4 method for sorbent and protocol selection. The Elute 1 step recovers
neutral analytes.
Proof of concept
Application of protocol 1 or 2
Prednisone: neutral
33
E X PERIMENTAL
Spike standards
into blank matrix
Each of the above compounds was spiked into rat plasma. The
concentrations and structures are shown in Figure 4.
CH3
CH3
CH3
CH3
OH
OH
CH3
H 3C
CH3
Valethamate (QA)
pKa > 12
2 ng/mL
CH3
Imipramine (B)
pKa = 9.4
2 ng/mL
Prednisone (N)
10 g/mL
CH3
Spike standards
into extracted matrix
CH3
F
O
CH3
Sample
matrix
(with analyte(s))
Post-extracted
spiked sample
OH
H 3C
OH
Ibuprofen (A)
pKa = 5.2
200 ng/mL
Extracted sample
(with analyte(s))
% RE = 100 x
RESPONSE
Extracted sample
(with anatlyte(s))
RESPONSE
Post-extracted
spiked sample
Each plasma sample was diluted (1:1 v/v) and acidified with
MD tip: collect and save all load and wash steps (to be
and calculated.
34
Protocol
Protocol 11
Oasis MCX
CONC LUSION
Protocol
Protocol 22
Oasis WAX
Oasis WCX
Oasis MAX
% SPE Recovery
E lu te 1 :
M eO H
80
60
E lu te 2 :
6 0 :4 0
A C N /M e O H
+ m o d ifie r
40
20
APPLICATION E X AMPLE II
ate
tham
Vale ( sb)
ne
niso
Pred (n)
n
rofe
Ibup a)
(
ne
niso
Pred (n)
id
ic Ac
tano
en
orop
aflu
Non ( sa )
ne
niso
Pred n)
(
ine
ram
Imip(b)
ne
niso
Pred (n)
The matrix effect was also calculated for each analyte, Figure 7.
Enhancement
Oasis MCX
Oasis WAX
Oasis MAX
Oasis WCX
40
30
20
10
th
Vale
ama
te
-40
rofe
-30
Ibup
-20
n
enta
orop
aflu Acid
Non
-10
ine
ram
Imip
Suppression
oic
Figure 7 shows that the matrix effects were very low when the
35
E X PERIMENTAL
The samples prepared using PPT yielded a high recovery for all the
drug compounds.
Condition/equilibrate cartridge
in
e
ni
ra
m
in
Im
e
ip
r
Am am
itr ine
ip
ty
lin
e
ap
Cl
Ch
lo
rp
he
id
er
sp
Ri
oz
on
on
id
er
sp
Ri
in
e
lo
l
dr
he
ep
20
9-
40
At
en
o
accepted standard)
ACN PPT
Basified LLE
Oasis MCX
MeOH
60
do
80
eu
PPT
100
Ps
50:50 MeOH/H2O
LLE
10
0
--1 0
--2 0
--3 0
--4 0
--5 0
--6 0
--7 0
--8 0
--9 0
Ps
eu
matrix effects were calculated using the post extraction spike method.
20
A
do ten
ep o l
O
he ol
H
d
Ri
sp rin
er e
Ri ido
sp
n
er e
id
on
Ch
Cl
e
lo
rp oza
he
pi
n
ni
ra e
Im mi
ne
ip
r
Am am
itr ine
ip
ty
lin
e
9-
Enhancement
Suppression
36
ACN PPT
Basified LLE
Oasis MCX
MeOH
CONC LUSION
Both liquid/liquid extraction and protein precipitation offer some
form of cleanup, but with each the analyst must make compromises
in recovery or cleanliness.
The samples prepared using Oasis MCX for solid-phase extraction
yielded excellent recovery and cleanliness with no compromises.
Thus matrix effects can be eliminated using Oasis MCX for a robust
reliable method that is inherently consistent. n
References
Chambers E, Wagrowski-Diehl D, Lu Z, Mazzeo, J. J. Chromatogr. B. 2007;
852 (1-2), 22-34.
37
38
INTRODUC TION
regulated laboratories.
becomes quantitative.
researched
mine accumulated data for the right information in the right format.
MassLynx Software
development
out these functions and the ways in which they interface to yield
an efficient, enhanced laboratory and business environment.
out-of-range data
characterization processes
spectrometrists.
39
NuGenesis SDMS
The volumes of data produced by one laboratory or a number of
laboratories can range from raw data to printed reports and all
stages in between. Accessing and mining this data can be an
Within any laboratory there are many tools and techniques in use,
bioanalytical laboratory.
rests on the outcome of the collated information, then tools that can
manage the data and information will provide valuable time savings.
of all scientific information and data has the potential for coordinating
Management of workflow
and manages all scientific information. Data from files and printed
are performed, and the related raw data are created. The raw data
are reusable through unique built-in tools that allow the user to
specific software used to generate the information. Data and information are then assimilated into a report for review and sign-off.
Each technique will produce a set of data that now must be archived
All the data and information can now be reused for evaluation and
creating reports that are best suited for final purpose. Compatibility
or client summaries
n
40
REPORT
SAMPLING
EVALUATION
ANALYTICAL DATA
GENERATION
REPORT
CREATION
FILE CAPTURE
REVIEW &
SIGN-OFF
PRINT CAPTURE
Analytical
Data
Integration
NuGenesis
SDMS
Result
Integration
COMMUNICATION
DOCUMENTATION
REVIEW &
SIGN-OFF
Decision
Figure 1. For a typical laboratory workflow, Waters informatics products such as NuGenesis SMDS creates a process-driven business logic that addresses the entire lifecycle of scientific
results, from data transfer between instrumentation software to creating and storing final reports.
APPLICATION E X AMPLE
Challenge
Impact
Solution
compliant environment.
41
Conc lusion
Improving the flow of data and information through a laboratory can
positively impact a company by enabling faster realization of the
knowledge and understanding required to make informed decisions,
and to communicate with interested and vested parties for better
business practices.
Waters informatics solutions for the laboratory provide a total
solution for information flow in the bioanalytical laboratory.
Developed by scientists, for scientists, Waters understands the
information management needs and business demands placed
on a bioanalytical laboratory as well as the specific needs of the
analytical scientist. n
42
T H E WAT E R S A C Q U I T Y U P L C S YS T E M
Increasing productivity and profitability in quantitative bioanalyses
Client: A Contract Research Organization
BAC KGROUND
As part of the drug development process, the safety and efficacy of drugs and their metabolites
must be tested and demonstrated. The primary role of a contract research organization (CRO) is to
quantify drug and metabolite concentrations in biological samples received from preclinical and
clinical studies.
There are four main areas within which CROs receive samples:
1. Preclinical: Multiple animal species studies (i.e. primate, dog, rodent, etc.), with a large number
of studies, but small sample numbers; moderate throughput analysis required
2. Clinical Phase I: First in-human study, with volumes of approximately 1,000 samples;
high throughput analysis required
3. Clinical Phase II: Dose range and efficacy study, with thousands of samples; moderate
throughput analysis required
4. Clinical Phase III: Wider patient studies, with tens of thousands of samples, but over an extended
period of time; moderate throughput analysis required
CROs typically use HPLC/MS/MS quantitative analysis for these samples due to its
sensitivity and selectivity.
C hall enge
Contract research laboratory revenues depend upon the number of samples that they can run. They
have streamlined workflows in place to run samples in a highly efficient process, similar to a production line. The main issue CROs face is obtaining the maximum throughput and quality possible
using their LC/MS/MS resources.
Pharmaceutical companies often require CROs to develop and validate their analytical methodol-
ogy prior to sample analysis. Method development can be a time-consuming process, as several
experiments have to be carried out prior to starting method validation. Such experiments include:
sensitivity and linearity tests over different ranges, sample preparation experiments, qualitative
matrix effects, etc. All of these experiments require instrument time that does not generate
revenue and can take weeks to complete if the assay is problematic.
Preclinical sample analysis can also be challenging and normally involves a large number of
studies spread out over an extended period of time, but with limited sample numbers. Results
from these studies are required quickly.
43
productivity.
[BUSINESS SOLUTION]
Due to lengthy HPLC run times, the CRO often has to analyze small
amounts of profit for the CRO, but there are several bottlenecks
results processing.
good starting point for the SPE method. The development plate
requires the analysis of 96 extracts. With UPLC, the method de-
T he Solut ion
suitable.
UPLC. The HPLC methods run time is 5.5 minutes, while the UPLC
run time is 1.5 minutes, a three-fold increase in throughput.
44
Business Benefit
Taking these steps into account, a method that takes one week
to develop by HPLC/MS/MS can be ready within two days using
working day and the LC/MS/MS performed during the night. When
generating samples.
of samples are analyzed per day. With UPLC this increases to six
Revenue Generated
to be analyzed.
HPLC
UPLC
Per Day
$12,000
$36,000
Per Week
$60,000
$180,000
Per Year
$3,120,000
$9,360,000
with UPLC.
45
Waters Corporation
34 Maple Street
Milford, MA 01757 U.S.A.
T: 1 508 478 2000
F: 1 508 872 1990
www.waters.com
46
T H E WAT E R S A C Q U I T Y U P L C / M S / M S S YS T E M
Increasing efficiency, productivity, and profitability for bioequivalence laboratories
Client: A Contract Research Organization in Latin America
Background
Bioequivalence testing involves confirmation of the profiles of active pharmaceutical ingredient
concentrations in human blood that has been sampled at various times following the administration of a referenced drug product and the generic test product.
The bioequivalence test, subject to U.S. FDA clinical and statistical standard procedures,
provides the basis for expecting that the drug products are, while not identically formulated or
manufactured, clinically comparable in safety and effectiveness in comparison to the referenced
drug. Because typical bioequivalence trials employ numerous subjects, each studied on multiple
occasions over a period of weeks per drug formulation, the costs are substantial to those
companies charged with adequately demonstrating safety and effectiveness.
C hall enges
To meet FDA requirements and specifications, manufacturers and contract research organizations
(CROs) must undertake rigorous, time-consuming, and extensive chemical analyses of the active
and inactive ingredients in the drug product using analytical methods such as chromatography and
mass spectrometry. Methods need to be acceptable in terms of linearity, sensitivity, selectivity,
accuracy and precision, stability, and carryover.
Maintaining profitability depends largely on the number of studies an organization can complete
while meeting FDA criteria. And because each study can involve thousands of samples across a
wide range of complex molecules, achieving maximum laboratory operational efficiency is critical
to remaining competitive.
One Latin American CRO laboratory was routinely employing HPLC with UV detection and
electrochemical detection. The lab often had issues with sensitivity, which meant that defining
pharmacokinetic profiles accurately could prove difficult especially at low dosages. Subsequent
sample concentration and matrix issues led to frequent sample re-analysis and a general lack of
reproducibility. Thus, the time of analysis per sample was too long in many cases, affecting the
completion of the study, as well as bottom-line costs and profitability.
T he Solut ion
Implementing the Waters ACQUITY UltraPerformance LC (UPLC) System with a Waters tandem quadrupole mass spectrometer made a
substantial and immediate difference in the efficiency of this CRO laboratory. The ACQUITY UPLC System reduced the time of analysis 50 to
70% depending on the product, with improved resolution and reproducibility. With this powerful UPLC/MS/MS system, the laboratorys problem
of lack of sensitivity was overcome with a selective and repeatable assay.
47
Business Benefit
the analysis of two molecules in the same run. The method was
linear, reproducible, specific and fast, taking only about four
Due to the fact that they could then have a quantifiable differentiation
48
Waters Corporation
34 Maple Street
Milford, MA 01757 U.S.A.
T: 1 508 478 2000
F: 1 508 872 1990
www.waters.com
ACQUITY UltraPerformance
technologically-advanced LC columns
LC (UPLC ) separation
higher chromatographic
technology.
UPLC/MS/MS performance.
49
www.waters.com/bioanalysis
Waters Corporation
34 Maple Street
Milford, MA 01757 U.S.A.
T: 1 508 478 2000
F: 1 508 872 1990
www.waters.com