ReleaseNotes

(9324-RL0x)RSLogix500supportstheAllen-BradleySLC500andMicroLogixfamiliesofprocessors.
Version10.00.00
CatalogNumberRSLogix500

Thesereleasenotesdescribeversioninformationfor(9324-RL0x)RSLogix500supportstheAllen-BradleySLC500andMicroLogixfamiliesof
processors.,RSLogix500,,version10.00.00.

SystemRequirements
Thisreleasehasthefollowingsystemrequirements.

SystemrequirementsforRSLogix500v.10.00
SupportedOperatingSystems:
Windows8.1(32-bitor64-bit)
WindowsServer2008and2012
Windows7(32-bitor64-bit)
WindowsVistawithServicePack,orlater
RSLogix500v.8.10andlaterrequireavalidserialnumberforinstallation.Thisensurestheserialnumberinformationisreadilyavailablefortechnical
supportandallowsthecorrecteditionofRSLogixtobeactivatedwhenusingFactoryTalkconcurrentactivations.
RSLogix500v.10.00supportsFactoryTalkActivation.ForinformationaboutFactoryTalkActivationrefertoActivateYourRockwellSoftwareProducts,which
camewithyoursoftware(andisalsoavailableduringinstallation).

Important:Forthelatestinformationregardingsoftwareplatform
support,referto
http://www.rockwellautomation.com/compatibility/#/scenarios
WindowsVistaUsers:RSLogix500requiresthatyouuseRSLinxClassicv.2.53orlaterwhenrunningunderWindowsVista.TorunRSEmulate500
underWindowsVista,RSLinxClassicv.2.55orlaterisrequired.
Windows7Users:RSLogix500requiresthatyouuseRSLinxClassicv.3.71.00orlaterwhenrunningunderMicrosoftWindows7.
FactoryTalkServicesPlatform:
FactoryTalkServicesPlatformhasbeenupdatedtoversion2.74.00,CPR9SR7.4.PleaserefertotheReleaseNotesforFactoryTalkServicesPlatformfor
moreinformation.WeadvisethatyouusetheNotifyMebyEmailoptiontokeepuptodateonchangesinFactoryTalkServicesPlatform.
UpdatingRSLogix500:
InstallinganolderversionofRSLogixoveranewerversion:InordertoinstallanolderversionofRSLogix500overanewerversion,youmustfirst
uninstallthenewerversionbyusingtheWindow'sControlPanel'sAdd/RemovePrograms.Youcaninstallanewerversion(v.6.3xorlater)without
uninstallingtheoldversionfirst.
RSLogix500andRSLogixMicrocannotbeinstalledonthesamecomputer.

SystemFeatures
Thisreleaseincludesthefollowingsystemfeatures.
CurrentenhancementsinRSLogix500v.10.00
ThefollowingenhancementsinthisreleaseofRSLogix500are:
SupportforSLCcontrollers:
1747-L531F
1747-L532F
1747-L533F
1747-L541D
1747-L543D
7147-L551D
1747-L552D
1747-L553D
Web-basedonlinehelpsupportsmulti-platformbrowsers,robustsearches,individualuserpreferences,andbookmarks.
SupportforWindows2012OS
UpdatethecurrentversionofFactoryTalkActivationv.3.62.11,CPR9SR6.1.
UpdatethecurrentversionofRSLinxClassicv.3.74.00,CPR9SR7.4.

UpdatethecurrentversionofFactoryTalkServicesPlatformv.2.74.00,CPR9SR7.4.
RSLogixProjectMigratorisincludedwiththisreleaseofRSLogix500.WithIntegratedArchitectureBuilder,RSLogixProjectMigratorhelpsmigrate
fromSLC500orMicroLogixcontrollerstoLogixcontrollers.

CorrectedAnomalies
Thisreleasecorrectsthefollowinganomalies.
FixedanomaliesinRSLogix500v.10.00
ThefollowingisalistofanomaliesfixedinthisversionofRSLogix500.
FactoryTalkSecurityfailedtoinstallwhenupgradingtoFTView8.0CPR9SR7withRSLogix500.
RSLogix5000supportstwo-byteattributesbutRSLogix500onlysupportedaone-byteattributewhenconfiguredinaMicroLogix1100/1400CIP
GenericMSGinstruction.TheMicroLogix1100/1400firmwareandRSLogix500softwarenowsupporttwo-byteattributesbymovingthevaluesintothe
RIXfilevialadderlogic.(Customerticket4002001080.)
WithMicroLogix1400SeriesBFRN12,theS:1/5ForcesEnabledbitcanbeclearedintheofflinefiletodisableforces.Whenforcesaredisabled
(S:1/5=0),theEnableAllForcesoptionwasavailableinthedropdownbox.However,selectingthisoptiondidnotenableforces.Theresolutionswith
ML1100B/ML1400B,forthisreleaseare:
TheEnableAllForcesoptionisactiveregardlessofwhetherforcesareinstalled.Inpreviousreleases,ifforceswerenotinstalled,theForces
Disabledoptionwasinactive,andtheForcesEnabledoptionwasalwaysactive.
Whenonlineandforcesareinstalled,theForceEnable/Disabledown-arrowisinactive.
Ifafilewasopenandthenetworkconnectionislostandthenrestored,RSLogix500wasnotbeabletosavethefile.Resolvedinthisrelease.
ResolvedtheMicroLogixprojectbuilderrorfor1746-NO8Vmodule.
Correctedthe1746NR8ModuleExcitationcurrentselection.Changed0.5mAmpto0.25mAmp.
MicroLogix1400SeriesBFRN12cancleartheForcesEnabledbit,S:1/5,intheofflinefile.Oncethefileisisdownloadedtothecontroller,forcesare
disabled.However,RSLogix500v9.0andearlier,automaticallysetthisbitintheofflinefile,thusre-enablingforceswithoutanyuserintervention.This
occurredwhen:
-1.
1.
1. OncetheS:1/5bitiscleared(ForcesDisabled),saveandclosethefile.Whenthefileisreopened,S:1/5willbesetagain(Forces
Enabled).
OncetheS:1/5bitiscleared(ForcesDisabled),downloadthefileandgoonline-forcesaredisabled.GoofflineandS:1/5willbeset
again(ForcesEnabled)intheofflinefile.
2. Thisissueisresolvedinthisrelease.RSLogix500doesnotsetthisbitwithoutuserinterventioninanyMicroLogixcontroller.
Resolvedtheissuewhereauser-definedfooterbitmapdoesnotshowupintheprintpreview.
ThisreleaseofRSLogix500allowsfordefaultdomainnamesoftwocharacters.
IntheDNP3DataSetDescriptorwindowwhenyouopenedthe5thelementPTYPpage,multipleElement5PrototypeConfigurationtabs
appearedonthewindow.Resolvedinthisrelease.
IntheDNP3DataSetDescriptorwindow,whenthedescriptorhadthemaximumof10dataelementsandthetenthelementwasaprototype,when
youopenedthetenthelement'sPTYPpagefordescriptor,andclickedOK,thesystemcrashed.Resolvedinthisrelease.

KnownAnomalies
Thisreleasehasthefollowingknownanomalies.
KnownanomaliesinRSLogix500v.10.00
ThefollowingisalistofknownanomaliesatthetimethisversionofRSLogix500wasreleased.
SelectingCrossReferenceforanaddressintheladdereditorisslowwhenonlinewithaSLC5/05processorwithaprojectcontainingmanycomplex
instructionssuchasEEM,DEM,CEM,andMSG.
UnderWindowsVistaorlateroperatingsystems,orasanadminonavirtualmachine,ifUserAccountControl(UAC)isenabled,youmaybe
promptedtoconfirmyourAdministratorprivilegeswhenexecutingcertaintasks(likeimport/export).IfyoudonothaveAdministrativeprivileges,
contactyourSystemAdministrator.
OnlineeditingofarungwithanLBLinstructionfailsonanSLC500processorinremoterunmodeifthematchingJMPinstructionexistsintheproject
andUNTESTisselected.OneworkaroundistoputtheLBLinstructiononitsownrung.
InaMicroLogix1200orMicroLogix1500project,ifaCLRinstructionwithanHSC:0.ACCorHSC:1.ACCoperandexistsintherungwithanested
branch(forexample:BSTXICB3:0/0CLRHSC:1.ACCNXBADD0N12:1N7:0BND),theprojectverificationwillfailandacompilererrorwillbe
displayed.
RSLogix500willnotallowtheuseofaFloatingPointconstantinanSCPinstruction.
WithaMicroLogix1500LRPSeriesCChannel1Radiomodem,thebroadcastmessagedestinationnode1isnotacceptedwhenverifyingtheproject.
TheerrormessageinvalidlocalDH-485StationNumber(0-254)displayseventhough1isavalidlocalDH-485stationnumberwhenChannel1isset
forDF1Radiomodemandabroadcastmessageisrequested.
InordertosupporttheMicroLogix1100SeriesBcontroller,RSLogix500handlesPTOandPWMfrequencies(PTO.OF,PTO.OFS,PTO.JF,PWM.OF,
andPWM.OFS)asunsigned16-bitintegers(0-65535)forMicroLogix1100SeriesB.IfyouareusinganolderversionofRSLogix500(version7.0
andversion7.10)withtheMicroLogix1100SeriesBcontroller,therewillbecompatibilityissues.Theseinclude:
RSLogix500displayissues:BecauseanolderversionofRSLogix500treatsPTO/PWMfrequenciesassignedintegers,ifyouuploada
programfromaMicroLogix1100SeriesBcontrollerintothesoftware,anegativefrequencyvaluemaybedisplayed.Forexample,40kHzis
0x9C40inhexadecimal.Thehexadecimalvalue0x9C40is40000inunsignedinteger,but-25536insignedinteger.
Instructionissues:AllinstructionsinMicroLogixcontrollerstreatintegersassignedintegers.Therefore,unsignedintegersinPTO/PWMfunction
fileelementsneedtobetreatedcarefullywhentheyareusedinthevariablesforinstructions.Anundesiredresultmaybereturnedormath
overflowmaybedetectedduringinstructionexecutions.AworkaroundshouldbeusedsuchascopyingPTO/PWMfrequenciestolonginteger

beforemanipulation.ForgreaterdetailrefertoAppendixF:Howtouse40kHzPTO/PWMofMicroLogix1100SeriesBController,publication
1763-RM001.
Iftheaddressdescriptioninadatafileischanged,thedescriptionintheTrendappletcannotbeupdated.
WhenchangingDNP3DataSetconfigurationfromDataElement(DAEL)toPrototype(PTYP)severaltimes,RSLogix500maystopresponding.Inthis
event,restartRSLogix500.

FunctionalChanges
Thisreleasehasthefollowingfunctionalchangesfromthepreviousrelease.
Nonoteswerefound.

ApplicationNotes
Thisreleasehasthefollowingapplicationnotes.
ApplicationnotesforRSLogix500v.10.00
ThissectiondescribesthebehavioroftheRSLogix500softwareinparticularapplicationsorundercertaincircumstances.
YoucanonlyinstalloneversionoreditionofRSLogix500orRSLogixMicrowithinaWindowsoperatingsystem.
Whenopeningan.ACHfilewithDatabaseornativeImportA.I.Databasefilefunctions,youmustopenthefileasanAdministrator.Otherwise,the
databaseinthe.ACHfilecannotbeimportedorthenativeImportA.I.Databasefileprocesswillfail.
DonotperformonlinesaveswiththeExceldatabaseeditor(Proonly)openasitcauseserrorsinthe.RSSfile
IfyouareusingRSLinxtoperformDDEcommunicationswithaprocessorandyoudownloadaprojecttothesameprocessor,thedownloadmayfail.
Ifthisoccurs,theprocessorloadsitsdefaultprogram.ToavoidthissituationceaseDDEcommunicationstoyourtargetprocessorwhenyou
plantodownloadaprojecttothesameprocessor.
Theprojectfile(projectname.RSS)containsbothanonlineandofflineimageofyourproject.Thisspeedstheprocessofconnectingtoaprocessor.
Theseimagescanbecomeunsynchronizedthisoccursifyoudonotsaveyourchangeswhengoingfromonlinetooffline.Tosynchronizetheimages,
youmustdownload,upload,orsavetheprojectwhileonline.
Theprojectfile(projectname.RSS)containsalldatabase-andproject-relatedfiles.Ifyouneedtoshareaprojectwithsomeone,providethemwith
theprojectname.RSSfileandtheywillreceiveallproject-relatedinformation.WhensharingRSLogixdatabaseinformationwithotherRockwell
AutomationSoftwareprograms,likeRSView32,youmustusetheSavedatabaseasexternalfilecheckboxontheFile>SaveAsdialogboxto
makethedatabasefileavailabletothatprogram.
RSLogix500printsladderlogicreportsasgraphicfiles.Theladderreportcannotbeprintedasatextfile.OtherRSLogix500reportscanbeprinted
asatextfileusingtheWindowstext-onlyprinterdriver.
ThefollowingcharacterscannotbeusedinRSLogix500symbols,`~!@#$%^&*()-+={}[]|\\:""'<>?,./.Ifyouhaveusedthesecharactersinaprevious
releaseofRSLogix500,thesymbolswillappearinyourladderviewsandreportshowever,youcannotmodifythesymbol.
-1.
1. WerecommendthatyouexportthedatabasetotheASCIICSVformattohelplocateillegalsymbolcharacters.

LegalNoticesinRSLogix500v.10.00
Copyrightnotice
2015RockwellAutomation,Inc.Allrightsreserved.PrintedinUSA.
ThisdocumentandanyaccompanyingRockwellSoftwareproductsarecopyrightedbyRockwellAutomation,Inc.Anyreproductionand/ordistributionwithout
priorwrittenconsentfromRockwellAutomation,Inc.isstrictlyprohibited.Pleaserefertothelicenseagreementfordetails.
EndUserLicenseAgreement(EULA)
YoucanviewtheRockwellAutomationEnd-UserLicenseAgreement("EULA")byopeningtheLicense.rtffilelocatedinyourproduct'sinstallfolderonyour
harddrive.
TrademarkNotices
RockwellSoftware,AdvancedInterfaceSeries,RSLogix,RSLogixMicro,MicroLogix,ControlLogix,SLC,RockwellAutomation,RSAssetSecurity,RSLinx,
SCANport,RSEmulate,FactoryTalkServicesPlatform,FactoryTalkDiagnostics,PowerFlex,RSTrendandFactoryTalkSecurityaretrademarksofRockwell
Automation,Inc.
AnyRockwellAutomationsoftwareorhardwarenotmentionedhereisalsoatrademark,registeredorotherwise,ofRockwellAutomation,Inc.
OtherTrademarks
Microsoft,Excel,VisualBasic,WindowsandActiveXareeitherregisteredtrademarksortrademarksofMicrosoftCorporationintheUnitedStatesand/or
othercountries.
Adobe,Reader,andAcrobatareeitherregisteredtrademarksortrademarksofAdobeSystemsIncorporatedintheUnitedStatesand/orothercountries.
InteliseitheraregisteredtrademarkortrademarkofIntelCorporationintheUnitedStatesand/orothercountries.
Allothertrademarksarethepropertyoftheirrespectiveholdersandareherebyacknowledged.
Warranty
Thisproductiswarrantedinaccordancewiththeproductlicense.Theproductsperformancemaybeaffectedbysystemconfiguration,theapplicationbeing
performed,operatorcontrol,maintenance,andotherrelatedfactors.RockwellAutomationisnotresponsiblefortheseinterveningfactors.Theinstructions
inthisdocumentdonotcoverallthedetailsorvariationsintheequipment,procedure,orprocessdescribed,nordotheyprovidedirectionsformeeting
everypossiblecontingencyduringinstallation,operation,ormaintenance.Thisproductsimplementationmayvaryamongusers.

Thisdocumentiscurrentasofthetimeofreleaseoftheproducthowever,theaccompanyingsoftwaremayhavechangedsincetherelease.Rockwell
Automation,Inc.reservestherighttochangeanyinformationcontainedinthisdocumentorthesoftwareatanytimewithoutpriornotice.Itisyour
responsibilitytoobtainthemostcurrentinformationavailablefromRockwellwheninstallingorusingthisproduct.
Environmentalcompliance
RockwellAutomationmaintainscurrentproductenvironmentalinformationonitswebsiteathttp://www.rockwellautomation.com/rockwellautomation/aboutus/sustainability-ethics/product-environmental-compliance.page
ContactRockwell
CustomerSupportTelephone1.440.646.3434
OnlineSupporthttp://www.rockwellautomation.com/support/

Copyright2015RockwellAutomation,Inc.Allrightsreserved.
RockwellAutomation,Allen-Bradley,andRockwellSoftwarearetrademarksofRockwellAutomation,Inc.
ToviewacompletelistofRockwellAutomationtrademarkspleaseclickhere.
TrademarksnotbelongingtoRockwellAutomationarepropertyoftheirrespectivecompanies.