Академический Документы
Профессиональный Документы
Культура Документы
com
e-mail http://www.lgeservice.com/techsup.html
LG
LG
Synchro
Air Conditioner
SERVICE MANUAL
CAUTION
BEFORE SERVICING THE UNIT, READ THE SAFETY
PRECAUTIONS IN THIS MANUAL.
ONLY FOR AUTHORIZED SERVICE PERSONNEL.
TABLE OF CONTENTS
Model Number Nomenclature ......................................................................3
Safety Precautions .......................................................................................4
Model Names...............................................................................................11
External Appearance ..................................................................................12
Dimensions .................................................................................................13
Product Specifications ...............................................................................21
Combination table ......................................................................................25
Installation...................................................................................................26
Operation ....................................................................................................61
Control Devices and Function ...................................................................76
Schematic Diagram ....................................................................................89
Piping Diagrams .......................................................................................100
Troubleshooting Guide.............................................................................105
(3-way) Valve ............................................................................................126
Function ....................................................................................................130
Exploded View & Replacement Parts List..............................................147
18
Serial Number
Function
A : Basic
E : E/Grille
F : Plasma + Elevation grille
Panel type
Cassette L : Basic panel, W : Wooden panel
Duct : L
Chassis type
Cassette : E/F/D, Convertible : E/B, Duct : H/G/R
Electrical Rating
6 : 1 220-240V ,50Hz
Nominal Cooling Capacity in Btu/h
Ex)18,000Btu/h '18', 24,000Btu/h '24'
Model Type
H : Heat Pump
Unit Type
N : Indoor Unit
U : Outdoor Unit
Outdoor Unit
A
100
U : Outdoor Unit
U : Universal,
B : Duct, T : Cassette
Refrigerent Type
A : R410A, L : R22
Service Manual 3
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must
be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
WARNING
CAUTION
WARNING
Installation
Have all electric work done by a licensed
electrician according to "Electric Facility
Engineering Standard" and "Interior Wire
Regulations" and the instructions given in
this manual and always use a special circuit.
If the power source capacity is inadequate or
electric work is performed improperly, electric
shock or fire may result.
Safety Precautions
For re-installation of the installed product,
always contact a dealer or an Authorized
Service Center.
Gasolin
When installing and moving the air conditioner to another site, do not charge it with a
different refrigerant from the refrigerant
specified on the unit.
If a different refrigerant or air is mixed with the
original refrigerant, the refrigerant cycle may
malfunction and the unit may be damaged.
Service Manual 5
Safety Precautions
Ventilate before operating air conditioner
when gas leaked out.
It may cause explosion, fire, and burn.
If the air conditioner is installed in a small room, measures must be taken to prevent the
refrigerant concentration from exceeding the safety limit when the refrigerant leaks.
Consult the dealer regarding the appropriate measures to prevent the safety limit from being exceeded. Should the refrigerant leak and cause the safety limit to be exceeded, harzards due to lack of oxygen in the room could result.
Operation
Do not damage or use an unspecified power
cord.
There is risk of fire, electric shock, explosion, or
injury.
Safety Precautions
When the product is soaked (flooded or
submerged), contact an Authorized Service
Center.
There is risk of fire or electric shock.
Do not open the inlet grill of the product during operation. (Do not touch the electrostatic
filter, if the unit is so equipped.)
CAUTION
Installation
Always check for gas (refrigerant) leakage
after installation or repair of product.
Low refrigerant levels may cause failure of
product.
90
Gasolin
Service Manual 7
Safety Precautions
Use power cables of sufficient current
carrying capacity and rating.
When installting the unit in a hospital, communication station, or similar place, provide
sufficient protection against noise.
The inverter equipment, private power generator,
high-frequency medical equipment, or radio communication equipment may cause the air conditioner to operate erroneously, or fail to operate. On the
other hand, the air conditioner may affect such
equipment by creating noise that disturbs medical
treatment or image broadcasting.
Do not install the product where it is exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins,
could cause product malfunction or inefficient operation.
Safety Precautions
Operation
Do not use the air conditioner in special
environments.
Oil, steam, sulfuric smoke, etc. can significantly
reduce the performance of the air conditioner or
damage its parts.
Install and insulate the drain hose to ensure that water is drained away properly based on the
installation manual.
A bad connection may cause water leakage.
Service Manual 9
Safety Precautions
Safely dispose of the packing materials.
Model Names
Model Names
Indoor Unit
Model Name
Indoor Unit
Nominal Capacity[Btu/h(Kw)]
Chassis
Name
Type
TE
Ceiling Cassette 4-Way
18,000
(5.3)
ATNH126ELFC ATNH186ELFC
24,000
(7.0)
30,000
(8.8)
36,000
(10.6)
48,000
(14.1)
60,000
(17.6)
TF
ATNH246FLFC
ATNH306FLFC
TD
VE
AVNH126ELAC
VB
AVNH186BLAC AVNH246BLAC
AVNH306BLAC
BH
ABNH186HLAC ABNH246HLAC
BG
ABNH306GLAC
ABNH366GLAC
BR
ABNH486RLAC
12,000
(3.5)
ATNH366DLFC ATNH486DLFC
ATNH606DLFC
ABNH606RLAC
Outdoor Unit
Model Name
Outdoor Unit
Type
MPS Variable
Nominal Capacity[Btu/h(Kw)]
Chassis
Name
48,000
(14.0)
60,000
(17.6)
72,000
(21.1)
100,000
(29.0)
UH
AUUH488C
UY
AUUH 728C
UW
AUUH1008C
Branch Kit
Name of accessory
Branch Kit
Model No.
PMUB11A
PMUB23A
PMUB111A
PMUB112A
PMUB122A
PMUB1111A
Indoor classification
"Synchro" Duo
"Synchro" Trio
"Synchro" Quartet
Capacity Ratio(%)
50:50(1:1)
40:60(2:3)
33:33:33(1:1:1)
25:25:50(1:1:2)
20:40:40(1:2:2)
25:25:25:25(1:1:1:1)
Remark
Unbalance type
Unbalance type
Unbalance type
Service Manual 11
External Appearance
External Appearance
Indoor Unit
Ceiling Cassette-4Way
ATNH126ELFC / ATNH186ELFC
ATNH246FLFC / ATNH306FLFC
ATNH366DLFC / ATNH486DLFC
ATNH606DLFC
AVNH126ELAC / AVNH186BLAC
AVNH246BLAC / AVNH306BLAC
Outdoor Unit
AUUH488C
AUUH728C
AUUH1008C
Dimensions
Dimensions
Indoor Unit
1. Cassette Type - TE(12K/18K)
39.5
269
570 Unit size
670
75
670
39.5
Unit:mm
570
670
450
521
670
570
CLOSE
OPEN
OPEN
CLOSE
40
4
30
160
52
190.5
110
90
90
120.4
30
269
110
(unit : mm)
Number
1
2
3
4
5
6
Name
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Power supply connection
Air discharge grill
Air suction grill
Descripition
6.35 flare
12k: 9.52, 18k: 12.7 flare
Service Manual 13
Dimensions
109
292
850
66
850
66
109
Unit:mm
658
744
850
850
572
744
6
70
4
(unit : mm)
Name
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Power supply connection
Air discharge grill
Air suction grill
Descripition
6.35 flare
24K: 12.7, 30K: 15.88 flare
212
150
90
Number
1
2
3
4
5
6
110
54
192
30
110
90
292
117
Dimensions
288
950
950
45
45
950
Unit:mm
840
840
785
950
678
55
40
210.5
52 180
110
90
110
90
140
290
30
(unit : mm)
Number
1
2
3
4
5
6
Name
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Power supply connection
Air discharge grill
Air suction grill
Descripition
36K: 6.35, 48K/60K: 9.52 flare
36K: 15.88, 48K/60K: 19.05 flare
Service Manual 15
Dimensions
61
205
63
38
10 Stud Bolt hole
26
39
250
2
128
36
46
8
175
76
10
(Rear Side)
(Installation Plate)
(Unit: mm)
36
More than
20cm
Note:
1. Pipe Specification(mm)
More than
20cm
Model
Liquid
Gas
18k, 24k
6.35
12.7
30k
6.35
15.88
More than
20cm
More than
20cm
1076
265
1076
mor
e th
260 an
Suspension bolt
(W3/8 or M10)
1236
265
Center-line for the
piping hole
265
123
Dimensions
A
B
i l
f
e
C
E
D
F
(G)
H
Note:
1. Pipe Specification(mm)
Model
Liquid
18, 24k
6.35
Gas
12.7
15.88
30, 36 k
9.52
48, 60k
19.05
(Unit: mm)
Capacity
C
D
E
ABNH186HLAC
ABNH246HLAC 932 882 355 45.5 450
ABNH306GLAC
1232 1182 355 45.5 450
ABNH366GLAC
ABNH486RLAC
1282 1230 477 56 590
ABNH606RLAC
Top view
(unit: mm)
(G)
30
87
750
30
87
830
30
110
130
52
66
81
30 158.5
116
160
53
59
81
19 158.5
120 1006 294 380 215 279 241 279 185 168
51
98
83
17
232 243
172
Front view
Inspection hole
(600X600)
Control box
600
1000
Front
600
Suitable dimension "H" is necessary
to get a slope to drain as figure.
Service Manual 17
Dimensions
4-hole for anchor bolts
AUUH488C
L1
L2
L3
L4
Control cover
L5
L10 L11
Liquid side
3-way valve
L7
L6
L8
L9
Model
Dimensions
W
mm
H
mm
D
mm
L1
mm
L2
mm
L3
mm
L4
mm
L5
mm
L6
mm
L7
mm
L8
mm
L9
mm
L10
mm
L11
mm
mm
1
mm
2
AUUH488C
900
1,165
370
460
45
410
1,135
30
550
175
175
112
120
83
9.52
19.05
Gas side
3-way valve
Dimensions
AUUH728C
806
500(bolt hole)
153
730
700(bolt hole)
690
15
153
40
Air outlet
Air
inlet
1512
1444
Air
inlet
100
28
670
Service Panel
Knockout hole
(For the control wiring,
the power supply,
refrigerant connecting
pipe)
220
Knockout hole
(For the control wiring, the power supply,
refrigerant connecting pipe)
(Unit : mm)
Service Manual 19
Dimensions
AUUH1008C
900(bolt hole)
190
690
Air outlet
48
730
700(bolt hole)
15
1280
190
Air
inlet
1444
1555
Air
inlet
670
Service Panel
Knockout hole
(For the control wiring, the power supply,
refrigerant connecting pipe)
33
63
100
160
Knockout hole
(For the control wiring,
the power supply,
refrigerant connecting
pipe)
45
60
Product Specifications
Product Specifications
Indoor Unit
Ceiling Cassette - 4way
Indoor unit
Decoration panel
kcal/hr(W)
Btu/hr
kcal/hr(W)
Btu/hr
CMM(CFM)
C
W
W
A
F/Vac
EA/inch(mm)
rpm
rpm
dBA
inch(mm)
l/h
inch(mm)
inch(mm)
kg(lbs)
inch(mm)
inch(mm)
mm
inch(mm)
20/40ft
ATNH126ELFC
PT-HEC1
ATNH186ELFC
PT-HEC1
3024(3517)
12000
3478(4044)
13800
9.5/8/7(336/283/247)
18~30/16~30
18.3
IC-9630LGAE
6
75
0.35
2.5/440
Turbo Fan
1/13.0(330)
670/620/550
670/620/550
38 / 35 / 32
Thermistor
0.275(7.0)
19
2R11C
1.2
22.4*10.5*22.4 (570*269*570)
26.4*1.2*26.4 (670*30*670)
19(41.9)
1/4(6.35)
3/8(9.52)
1.26(32)
25.2*13.0*25.2 (640*330*640)
189/378
4536(5275)
18000
5116(5949)
20300
13/12/11(459/424/388)
18~30/16~30
22.4
IC-9630LGAC
6
90
0.75
2.5/440
Turbo Fan
1/13.0(330)
720/670/620
720/670/620
41 / 39 / 37
Thermistor
0.275(7.0)
19
2R11C
2.4
22.4*10.5*22.4 (570*269*570)
26.4*1.2*26.4 (670*30*670)
19(41.9)
1/4(6.35)
1/2(12.7)
1.26(32)
25.2*13.0*25.2 (640*330*640)
189/378
ATNH366DLFC
PT-HDC1
Indoor unit
Decoration panel
ATNH306FLFC
PT-HFC(F)
6048(7033)
7056(8205)
24000
28000
6955(8089)
8114(9437)
27600
32200
15/14/13(523/494/459)
19/17/15(671/600/550)
18~30/16~30
18~30/16~30
40.3
48.6
OBM-3502P2
OBM-4105P2
6
6
121
146
0.53
0.67
4/440
4/440
Turbo Fan
Turbo Fan
1/15.0(382)
1/15.0(382)
600/540/480
650/600/550
600/540/480
650/600/550
43 / 41 / 39
45 / 42 / 39
Thermistor
Thermistor
0.275(7.0)
0.275(7.0)
21
21
2R12C
2R12C
3
3.3
29.3*11.5*29.3 (744*292*744) 29.3*11.5*29. (744*292*744)
33.5*1.2*33.5 (850*30*850)
33.5*1.2*33.5 (850*30*850)
24(52.9)
24(52.9)
1/4(6.35)
1/4(6.35)
1/2(12.7)
5/8(15.88)
1.26(32)
1.26(32)
32.6*14.4*32.6 (828*365*828) 32.6*14.4*32.6 (828*365*828)
84/168
84/168
ATNH246FLFC
PT-HFC(F)
kcal/hr(W)
Btu/hr
kcal/hr(W)
Btu/hr
CMM(CFM)
C
W
W
A
F/Vac
EA/inch(mm)
rpm
rpm
dBA
inch(mm)
l/h
inch(mm)
inch(mm)
kg(lbs)
inch(mm)
inch(mm)
mm
inch(mm)
20/40ft
Notes:
1. Capacities are based on the following conditions:
Cooling : - Indoor Temperature 27C(80.6F) DB / 19C(66.2F) WB
- Outdoor Temperature 35C(95F) DB / 24C(75.2F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Heating : - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
9072(10549)
36000
10433(12130)
41400
25/23/21(883/812/742)
18~30/16~30
52.5
IC-1630LGPJ
6
175
0.76
4/440
Turbo Fan
1/18.1(460)
550/510/470
550/510/470
40 / 38 / 36
Thermistor
0.275(7.0)
21
2R 12C
4
33.1*11.3*33.1 (840*288*840)
37.4*1.2*37.4 (950*30*950)
32(70.4)
1/4(6.35)
5/8(15.88)
1.26(32)
36.4*13.8*36.4 (925*350*925)
72/144
ATNH486DLFC
PT-HC1
ATNH606DLFC
PT-HDC1
12095(14067)
48000
13305(15474)
52800
30/28/26(1059/988/918)
18~30/16~30
58.5
IC-1640LGPH
6
195
1.5
6/400
Turbo Fan
1/18.1(460)
600/555/520
600/555/520
43 / 41 / 39
Thermistor
0.275(7.0)
21
2R 12C
5.5
33.1*11.3*33.1 (840*288*840)
37.4*1.2*37.4 (950*30*950)
32(70.4)
3/8(9.52)
3/4(19.05)
1.26(32)
36.4*13.8*36.4 (925*350*925)
72/144
14112(16412)
56000
15523(18053)
61600
34/32/30(1200/1130/1059)
18~30/16~30
107
IC-14640LGPM
6
237
1.8
6/400
Turbo Fan
1/18.1(460)
700/650/600
700/650/600
50 / 47 / 43
Thermistor
0.275(7.0)
21
2R 12C
6.5
33.1*11.3*33.1 (840*288*840)
37.4*1.2*37.4 (950*30*950)
32(70.4)
3/8(9.52)
3/4(19.05)
1.26(32)
36.4*13.8*36.4 (925*350*925)
72/144
Service Manual 21
Product Specifications
Ceiling Concealed Duct - High Static
Model
Rated Cooling Capacity
Ratedl Heating Capacity
Air Circulation
Indoor(H/M/L)
Setting temperature range
Fan motor
Output
Model
No. of Poles
Input
Running Current
Capacitor
Fan
Type
No. Used / Diameter
Fan RPM
Cooling(H/M/L)
Heating(H/M/L)
Noise Level(Sound Press,1m) H/M/L
Temperature controller
Coil
Tube Size (OD)
Fins per inch
No. of Rows & Column
Dehumidification Rate
Dimensions (W*H*D)
Indoor
Panel
Net Weight
Piping
Liquid
Connection
Gas
Drain hose (ID )
Packing Dimension (W*H*D)
Stuffing Quantity
Without(Without) S/Parts
kcal/hr(W)
Btu/hr
kcal/hr(W)
Btu/hr
CMM(CFM)
C
W
W
A
F/Vac
EA/inch(mm)
rpm
rpm
dBA
inch(mm)
l/h
inch(mm)
inch(mm)
kg(lbs)
inch(mm)
inch(mm)
mm
inch(mm)
20/40ft
ABNH366GLAC
Model
kcal/hr(W)
Btu/hr
kcal/hr(W)
Btu/hr
CMM(CFM)
C
W
W
A
F/Vac
EA/inch(mm)
rpm
rpm
dBA
inch(mm)
l/h
inch(mm)
inch(mm)
kg(lbs)
inch(mm)
inch(mm)
mm
inch(mm)
20/40ft
9072(10549)
36000
10433(12130)
41400
32/29/26(1130/1024/918)
10
18~30/16~30
272
IC-13470LG13A
4
323
1.42
6/370
Sirocco Fan
2/6.97(177)
1415/1360/1290
1415/1360/1290
42 / 39 /36
Thermistor
0.275(7.0)
21
3R 12C
4
46.5*11.7*17.7 (1180*298*450)
38(84)
1/4(6.35)
5/8(15.88)
25.4
56.5*14.8*22.9 (1435*375*582)
95/191
Notes:
1. Capacities are based on the following conditions:
Cooling : - Indoor Temperature 27C(80.6F) DB / 19C(66.2F) WB
- Outdoor Temperature 35C(95F) DB / 24C(75.2F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Heating : - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. Capacities are Net Capacities.
3. Due to our policy of innovation some specifications may be changed without notification.
6048(7034)
24000
6955(8089)
27600
18/16.5/14(636/583/494)
8
18~30/16~30
118
IC-13450LG13C
4
180
0.92
6/370
Sirocco Fan
2/6.97(177)
1410/1350/1250
1410/1350/1250
38 / 36 /34
Thermistor
0.275(7.0)
21
3R 10C
2.5
34.6*10.2*17.7 (880*260*450)
35(77.2)
1/4(6.35)
1/2(12.7)
25.4
44.7*13.4*22.0 (1135*340*565)
120/252
ABNH306GLAC
7560(8791)
30000
8694(10110)
34500
26.5/23/20(936/812/706)
10
18~30/16~30
211
IC-13450LG13J
4
300
1.34
6/370
Sirocco Fan
2/6.97(177)
1415/1360/1290
1415/1360/1290
40 / 38 /35
Thermistor
0.275(7.0)
21
3R 12C
3.3
46.5*11.7*17.7 (1180*298*450)
38(84)
1/4(6.35)
5/8(15.88)
25.4
56.5*14.8*22.9 (1435*375*582)
95/191
ABNH246HLAC
4536(5275)
18000
5116(5949)
20300
16.5/14.5/13(583/512/459)
8
18~30/16~30
118
IC-13450LG13C
4
180
0.92
6/370
Sirocco Fan
2/6.97(177)
1350/1310/1270
1350/1310/1270
36 / 34 /32
Thermistor
0.275(7.0)
21
2R 10C
2
34.6*10.2*17.7 (880*260*450)
35(77.2)
1/4(6.35)
1/2(12.7)
25.4
44.7*13.4*22.0 (1135*340*565)
120/252
ABNH486RLAC
12095(14067)
48000
13305(15474)
52800
40/35/30(1413/1236/1059)
15
18~30/16~30
431
Y002276-1
4
818
3.65
15/450
Sirocco Fan
2/9.1(230)
1063/1035/983
1063/1035/983
44/42/40
Thermistor
0.375(9.52)
19
3R13C
6
48.4*15.0*23.2 (1230*380*590)
60(132)
3/8(9.52)
3/4(19.05)
25.4
56.9*17.9*27.6 (1445*455*700)
57/120
ABNH606RLAC
14112(16412)
56000
15523(18053)
61600
50/45/40(1766/1413/1236)
15
18~30/16~30
431
Y002276-1
4
818
3.65
15/450
Sirocco Fan
2/9.1(230)
1113/1063/1035
1113/1063/1035
46/44/42
Thermistor
0.375(9.52)
19
4R13C
6.5
48.4*15.0*23.2 (1230*380*590)
60(132)
3/8(9.52)
3/4(19.05)
25.4
56.9*17.9*27.6 (1445*455*700)
57/120
Product Specifications
Ceiling & Floor (Convertible)
kcal/hr(W)
Btu/hr
kcal/hr(W)
Btu/hr
CMM(CFM)
C
W
W
A
F/Vac
EA/inch(mm)
rpm
rpm
dBA
inch(mm)
l/h
inch(mm)
kg(lbs)
inch(mm)
inch(mm)
mm
inch(mm)
20/40ft
AVNH126ELAC
AVNH186BLAC
AVNH246BLAC
AVNH306BLAC
3024(3517)
12000
3478(4044)
13800
10.0/8.3/6.5(353/293/230)
18~30/16~30
17.5
IC-18422LG31A
4
43
0.23
1.5/370
Cross Flow Fan
1/3.7(95)
1240/1120/900
1240/1120/900
40 / 36 / 31
Thermistor
0.197(5.0)
20
2R 12C
1.2
35.4*7.9*19.3 (900*200*490)
12(26.5)
1/4(6.35)
3/8(9.52)
20
38.2*11.2*22.2 (970*285*565)
189/383
4536(5274)
18000
5116(5949)
20300
13.5/12/11(477/424/388)
18~30/16~30
30
IC-9430LGCG
4
53
0.23
1.5/370
Cross Flow Fan
1/3.1(80)
1090/990/890
1090/990/890
43 / 40 / 37
Thermistor
0.275(7.0)
18
2R 12C
2.3
47.2*8.1*24.2 (1200*205*615)
30(66.1)
1/4(6.35)
1/2(12.7)
20
50.8*11.4*27.4 (1272*290*696)
102/219
6048(7032)
24000
6955(8089)
27600
15/13.5/12(530/477/424)
18~30/16~30
35
IC-9430LGCE
4
63
0.27
1.5/370
Cross Flow Fan
1/3.1(80)
1160/1060/960
1160/1060/960
45 / 42 / 39
Thermistor
0.275(7.0)
20
2R 14C
3.2
47.2*8.1*24.2 (1200*205*615)
30(66.1)
1/4(6.35)
1/2(12.7)
20
50.8*11.4*27.4 (1272*290*696)
102/219
6653(7377)
26400
7635(8880)
30300
18/16/14(636/564/494)
18~30/16~30
42.5
OBM-3019P2
4
81
0.38
1.5/370
Cross Flow Fan
1/3.1(80)
1220/1110/1010
1220/1110/1010
45 / 42 / 39
Thermistor
0.275(7.0)
20
2R 14C
3.5
47.2*8.1*24.2 (1200*205*615)
30(66.1)
1/4(6.35)
5/8(15.88)
20
50.8*11.4*27.4 (1272*290*696)
102/219
Notes:
1. Capacities are based on the following conditions:
Cooling : - Indoor Temperature 27C(80.6F) DB / 19C(66.2F) WB
- Outdoor Temperature 35C(95F) DB / 24C(75.2F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Heating : - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. Capacities are Net Capacities.
3. Due to our policy of innovation some specifications may be changed without notification.
Service Manual 23
Product Specifications
AUUH488C
AUUH728C
AUUH1008C
12096(14607)
48000
13305(15474)
52800
5300 / 5050
10.0 / 9.5
3,380~415,50
82
Single / Duo / Trio / Quartet
42 at 420V
Rotary
2
GPT330YAA
LG
6854(27200) at 50Hz & 380V
Three Phase Induction Motor
2550
FVC68D(PVE)
1200
Internal Type(UBUKATA)
4200(148.1)
R-410A
L.E.V
0.276(7.0)
17
2R 52C
70
AMR071B9
2/6
168
6/370
Propeller
2/18.1(460)
Side Discharge
900
53(1872*2)
56
3/8 (9.52)
3/4 (19.05)
35.4*45.8*14.5(900*1165*370)
105(231)
5*5.5 (Includes earth)
4*0.75 (Includes earth)
110
50
60
15
30
1
41.7*48.0*18.3(1060*1220*465)
27 / 55
18144(21101)
72000
19958(23211)
79200
8000 / 7700
14.7 / 14.4
3,380~415,50
80
Duo / Trio / Quartet
24 / 27
Rotary
3
5JS290PBA21
Matsushita Electric
6376(25301) at 50Hz & 380V
Three Phase Induction Motor
2680
FV50S(PVE)
1130
IT(Internal Thermostat)
7100(250.4)
R-410A
L.E.V
0.276(7.0)
17
2R 17C + 3R 36C + 2R 17C + 2R 36C
271
ARE676E01
1/6
429
1.87
10/370
Propeller
1/20.7(526)
Top Discharge
850
90(3179)
58
3/8 (9.52)
1 (25.4)
31.5*56.7*27.1(800*1440*690)
150(331)
5*5.5 (Includes earth)
4*0.75 (Includes earth)
110
50
60
15
30
1
34.4*61.0*29.7(875*1550*755)
18 / 39
24192(28135)
96000
27820(32355)
110400
11100 / 11000
20 / 19.7
3,380~415,50
83
Duo / Trio / Quartet
63 at 420V
Scroll
2
AR061YAA
LG
12625(50100) at 50Hz & 380V
Three Phase Induction Motor
5330
FVC68D(PVE)
1800
Internal Type(UP18TA057)
7800(275.1)
R-410A
L.E.V
0.276(7.0)
18
2R 17C + 1R 36C + 2R 17C + 2R 36C
271
ARE676E01
2/6
429
1.87
10/370
Propeller
2/20.7(526)
Top Discharge
850
185(6533)
60
1/2 (12.7)
1 (25.4)
50.4*56.7*27.1(1280*1440*690)
299(659)
5*5.5 (Includes earth)
4*0.75 (Includes earth)
110
50
60
15
30
1
53.1*62.6*29.9(1350*1590*760)
12 / 25
Model
Cooling Capacity
Heating Capacity
Input
Cooling/Heating
Running Current
Cooling/Heating
Starting Current
Cooling/Heating
Power Supply
Power Factor
Number of Connectable Indoor Units
Compressor
Locked Rotor Amp.
Type
Quantity
Model
Maker
Capacity
Motor Type
Motor Input
Oil Type
Oil Charge
O.L.P Type(model name)
Refrigerant
Charge *
Type
Control
Outdoor Coil
Tube Size (OD)
Fins per inch
No. of Rows & Column/No.
Outdoor fan motor
Output
Model
No. Used / No. of Poles
Input
Running Current
Capacitor
Outdoor Fan
Type
No. Used / Diameter
Discharge
Speed
Air Circulation
Outdoor
Noise Level(Sound Press,1m) Outdoor
SVC Valve
Liquid
Gas
Dimensions
W*H*D
Net Weight
Outdoor
Power Supply Cable
Connecting Cable
Max Interunit
Total Piping
Piping Length
Total Main Piping
Total Branch Piping
For One Room
Max. Installation
Indoor Unit - Outdoor Unit
Height Difference
Indoor Unit - Indoor Unit
Packing Dimension
(W*H*D)
Stuffing Quantity
With(Without) S/Parts
kcal/hr(W)
Btu/hr
kcal/hr(W)
Btu/hr
W
A
A
,V,Hz
%
A
No
kcal/hr(Btu/hr)
W
cc
g(oz)
inch(mm)
W
A
F/Vac
EA/inch(mm)
Side / Top
rpm
CMM(CFM)
dB(A)1
inch(mm)
inch(mm)
inch(mm)
kg(lbs)
No.* mm2
No.* mm2
m
m
m
m
m
m
inch(mm)
20/40ft
Combination table
Combination table
MPS Variable
AUUH488C
Synchro
Single
(1 Unit)
Duo
(2 Unit)
Trio
(3 Unit)
Quartet
(4 Unit)
AUUH728C
48
18 + 24 (2:3)
24 + 24 (1:1)
24 + 30 (2:3)
42
48
54
PMUB23A
PMUB11A
PMUB23A
18 + 18 + 18 (1:1:1)
54
PMUB111A
12 + 12 + 12 + 12 (1:1:1:1)
48
PMUB1111A
Synchro
Duo(2 Unit)
18 + 24 + 24(1:2:2)
Trio(3 Unit) 18 + 18 + 36(1:1:2)
24 + 24 + 24(1:1:1)
24 + 24 + 30(1:1:2)
Quartet
18 + 18 + 18 + 18
(4 Unit)
(1:1:1:1)
68
72
PMUB23A
PMUB11A
66
72
72
78
PMUB122A
PMUB112A
PMUB111A
PMUB112A
72
PMUB1111A
AUUH1008C
Synchro
36 + 48 (2:3)
36 + 60 (2:3)
Duo(2 Unit)
48 + 48 (1:1)
24 + 24 + 36(1:1:2)
Trio(3 Unit) 24 + 24 + 30(1:1:2)
30 + 30 + 30(1:1:1)
30 + 30 + 36(1:1:2)
30 + 36 + 36(1:2:2)
Quartet
(4 Unit)
24 + 24 +24 + 24
(1:1:1:1)
84
96
96
PMUB23A
PMUB23A
PMUB11A
84
84
90
96
102
PMUB112A
PMUB112A
PMUB111A
PMUB112A
PMUB122A
96
PMUB1111A
Service Manual 25
Installation
Installation
Read completely, than follow step by step.
Anti-bacteria filter
Air
Intake
Air Outlet
Required Parts
Required Tools
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Level
Screw driver
Electric drill
Hole core drill (70mm)
Flaring Tools set
Torque Wrenches
Hexagonal Wrench (4mm, 5mm)
Gas-leak detector
Owners Manual
Thermometer
50 or
more
Unit:cm
Floor
Ceiling Board
30 or less
50 or
more
Above 250
400 or less
Ceiling
Ceiling Board
100
or more
30 or more
Installation
Ceiling
Ceiling board
Level gauge
TF Model
39.5
109
572(Hanging bolt)
109
45
785(Hanging bolt)
66
75
45
521(Hanging bolt)
66
39.5
TD Model
TE Model
600 (Ceiling opening)
Unit:mm
Unit:mm
Unit:mm
CAUTION
This air-conditioner uses a drain pump.
Install the unit horizontally using a level gauge.
During the installation, care should be taken not to
damage electric wires.
NOTE:
Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
Make sure that ventilation fan is enough to cover all noxious gases from this place.
Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam.
Air conditioner
Take enough
distance
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table
2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.
Service Manual 27
Installation
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Spring washer
(M10)
Ceiling board
Paper pattern
for installation
150mm
Ceiling
Set screw of
paper pattern (4 pieces)
Open the ceiling board
along the outer edge of the
paper pattern.
CAUTION
Tighten the nut and bolt to prevent unit from
falling off.
3. Wiring Connection
Open the control box cover and connect the remote control cord and Indoor power wires.
Indoor
power cord
Remote
controller
cord
2(N)
WARNING
Make sure that the screws of the terminal are free from looseness.
Installation
1. Temporarily fix two decoration panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by
amount 10mm in length.)
The fixing screws (hexagon M5 screw) are included the indoor unit box.
2. Remove the air inlet grille from the decoration panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decoration panel key hole (
) on the screws fixed in step above, and slide the panel so
that the screws reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector and display connector.
6. After tightening these screws, install the air inlet grille (including the air filter).
Piping side
Louver
motor
Inlet Grille
Decoration panel
Display
Key holes
Lead wire for
louver motor and
display
Inlet Grille
CAUTION
Install certainly the decoration
Good example
panel.
Cool air leakage causes sweating.
Water drops fall.
Bad example
Air conditioner
unit
Ceiling
board
Decoration panel
Fit the insulator (this part) and
be careful for cool air leakage
Service Manual 29
Installation
Upward
routing
not allowed
Pipe clamp
Indoor unit
Maintenance
drain port
1/50~1/100
MAX 700mm
Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Flexible drain hose
(accessory)
Feed water
Main
drain pipe
Drain Pump
Drain
port
Drain pan
CAUTION
1/50~1/100
CAUTION
MAX 700mm
Installation
6. Accessories
Standard Accessories
Name
Drain hose
Clamp metal
Quantity
1 EA
1 EA
Washer for
hanging backet
8 EA
Clamp
Insulation for
fitting
8 EA
1 SET
Shape
(Other)
Item
Wireless remote
control
Central control
Type
AHWRHD
Simple
PQCSA101S0
Deluxe
PC Based
Model No.
PQCSW501A0
PQCSW502A0
PQCSS501A0
PQCSS502A0
PI485
PHNFP14A0
CNU
PQNFG00A0
Gateway
Elevation Grille
Kit
Decoration
panel
Component Parts
Wireless remote control : 1EA
Holder : 1EA
Battery : 2EA
Screw : 2EA
Simple central controller
Manual
Deluxe central controller
Manual
Program CD
Hard lock key, Manual
PCB & Wire assembly
Installation manual
(For all central control)
PCB & Wire assembly
(For Deluxe, PC Based central
control)
PT-HEF
PT-HFF
Remote controller
PT-HDF
Manual
Service Manual 31
Installation
1 -1
(Ceiling/Wall Mounting)
Suspension Bolt
Bolts for Mount Bracket
Connecting Tube(mm)
Gas side : 12.7, 15.88
Liquid side : 6.35
Connecting Cable
7
(Floor Mounting)
4
Required Parts
Required Tools
Installation Plate
Four Type A screws
Connecting cable
Level
Screw driver
Electric drill
Hole core drill (70mm)
Owners Manual
Thermometer
Installation
More than
20cm
More than
20cm
(Ceiling installation)
More than
20cm
More than
20cm
(Floor/Wall installation)
2. Wiring connection
AIR GUIDE-L
INDOOR UNIT
2(N)
4
Clamp
1
2
Control
Panel
2) Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly.
For the heat pump model, put the 0.75mm2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the
other boss of the control panel.
4) In Australia, the length of power supply cord measured from the entry of the power supply cord to the middle of live pin
on the power plug should be over 1.8m.
Service Manual 33
Installation
CAUTION
1. Install declination of the indoor unit is very important for the drain of the convertible type air
conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 7mm.
3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be declined
to the bottomside.
Front of view
The unit must be horizontal or declined to the drain hose connected when finished installation.
Ceiling
Drain hose
Ceiling
Side of view
The unit must be declined to the bottomside of the unit when finished installation.
Ceiling
Installation
CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power specially for the air conditioner. As for the method of
wiring, be guided by the circuit diagram pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to loose due to
vibrations to which the unit is subjected during the course of transportation. Check them and
make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the
wires.)
4) Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to
the normal function of a overload protection device.
Proper starting power is not given to the compressor.
10) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductors.
Service Manual 35
Installation
3. Accessories
Standard Accessories
Name
Drain hose
Clamp metal
Washer for
hanging backet
Clamp
Insulation for
fitting
Quantity
1 EA
1 EA
8 EA
6 EA
1 set
(Other)
Owner's manual
Installation manual
Shape
Item
Type
Simple
Central control
Deluxe
PC Based
Model No.
PQCSA101S0
PQCSW501A0
PQCSW502A0
PQCSS501A0
PQCSS502A0
PI485
PHNFP14A0
CNU
PQNFG00A0
Gateway
Component Parts
Simple central controller
Manual
Deluxe central controller
Manual
Program CD
Hard lock key, Manual
PCB & Wire assembly
Installation manual
(For all central control)
PCB & Wire assembly
(For Deluxe, PC Based central
control)
Installation
Air filters
Required Parts
Required Tools
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Level
Screw driver
Electric drill
Hole core drill (70mm)
Flaring Tools set
Torque Wrenches
Hexagonal Wrench (4mm, 5mm)
Gas-leak detector
Owners Manual
Thermometer
Inspection hole
(600X600)
Control box
600
1000
Install the air conditioner in the location that satisfies the following conditions.
The place shall easily bear a load exceeding four times the
indoor units weight.
The place should have enough area for inspection as shown
in figure.
The place where the unit shall be leveled.
The place shall allow easy water drainage.(Suitable dimension H is necessary to get a slope to drain as figure.)
The place shall easily connect with the outdoor unit.
The place where the unit is not affected by an electrical
noise.
The place where air circulation in the room will be good .
There should not be any heat source or steam near the unit.
600
Front
Front view
Service Manual 37
Installation
Installation of Unit
Install the unit above the ceiling correctly.
C
E
CASE 1
D
1-3 mm
(G)
H
Drainage hole
M10 Nut
X4
(Local
M10 SP. washer X 4 supply)
M10 washer
X4
M10 washer
CASE 2
X4
(Local
M10 SP. washer X 4 supply)
M10 Nut
X4
NOTE:
Throughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat
exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc.
In these cases, take the following actions:
Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily
steam which should not flow into the suction of the air conditioner.
Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam.
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.
Installation
Select and mark the position for fixing bolts.
Drill the hole for set anchor on the face of ceiling.
Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the
ceiling.
Mount the suspension bolts to the set anchor firmly.
Secure the installation plates onto the suspension
bolts (adjust level roughly) using nuts, washers and
spring washers.
Old building
New building
1 Set anchor
2 Plate washer
3 Spring washer
4 Nut
CAUTION
Tighten the nut and bolt to prevent unit falling.
5 Suspension
bolts
3. Connecting Cables
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively
Terminal Block in Indoor
1(L)
2(N)
WARNING
Make sure that the screws of the terminal are free from looseness.
Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the
0.75mm2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control
panel.
4) In Australia, the length of power supply cord measured from the entry of the power supply cord to the middle of
live pin on the power plug should be over 1.8m.
Service Manual 39
Installation
4. Insulation
THERMAL INSULATION
INDOOR UNIT
Installation
CAUTION
1. Decline Installation of indoor unit is very important for the drain of the duct type air conditioner.
2. Minimum thickness of the insulation for the connecting pipe should be 5mm.
Front of view
The unit must be or declined to wards drain hose while installation.
1~3mm
Ceiling
Drainage hole
CORRECT
Drainage hole
INCORRECT
Unit
CORRECT
Drainage hole
INCORRECT
1/50~1/100
Drain Pipe
MAX 700mm
B
C
U-Trap
A
Drain Pump
Service Manual 41
Installation
6. Accessories
Standard Accessories
Name
Clamp metal
Drain hose
Insulation for
fitting
Clamp
Screws for
duct flanges
Quantity
1 EA
1 EA
1 set
6 EA
1 set
(Other)
Owner's manual
Installation manual
Washers(8 pcs.)
Shape
Item
Wireless remote
control
Type
Model No.
AHWRHS
AHWRHD(LCD)
ABPAHH
-
ABPAGH
Component Parts
Wireless remote control : 1EA
Holder : 1EA
Battery : 2EA
Screw : 2EA
Plasm air purifier kit: 1EA
Wired remote control: 1EA
ABPARH
Zone Control
ABZCA
Drain Pump
ABDPG
Simple
PQCSA101S0
Deluxe
PQCSW501A0
PQCSW502A0
PC Based
PQCSS501A0
PQCSS502A0
Program CD
Hard lock key, Manual
PI485
PSNFP14A0
CNU
PQNFG00A0
Central Control
Gateway
Installation
Copper
tube
90
Pipe
Reamer
Point down
2. Burrs removal
Completely remove all burrs from the cut cross
section of pipe/tube.
Put the end of the copper tube/pipe to downward
direction as you remove burrs in order to avoid to let
burrs drop in the tubing.
Flare nut
3. Putting nut on
Copper tube
4. Flaring work
Carry out flaring work using dedicated flaring tool
for R-410A as shown below.
Outside diameter
mm
inch
6.35
1/4
9.52
3/8
12.7
1/2
15.88
5/8
19.05
3/4
A
mm
0~0.5
0~0.5
0~0.5
0~1.0
0~1.0
Handle
Bar
Bar
"A"
Yoke
Cone
Copper pipe
Clamp handle
5. Check
Compare the flared work with figure below.
If flare is noted to be defective, cut off the flared
section and do flaring work again.
= Improper flaring =
Even length
all round
Service Manual 43
Installation
Remote Controller
DISASSEMBLING
Separate the under plate from Remote control box.
Front case
Th
el
ow
er
Lever carefully
the box open
using a screw
driver, etc.
pa
rt
Remote control
box body
Cord clamp
(accessory)
Under plate
Screw (accessory)
ELECTRICAL WIRING
(Main board)
CN REMO
Installation
Outdoor Unit_AUUH728C
1. Selection of the best location
If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.
Do not place animals and plants in the path of the warm air.
Take the air conditioner weight into account and select a place where noise and vibration are minimum.
Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
Rooftop Installations : If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure
the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting.
2. Individual installation
Basic Space required
A space of at least 250 mm is nessary at the back for inlet air. Tacking servicing, a space of about 750 mm
should be provided at the front.
Rear
C
B
A
B
C
D
E
: 750 mm or more
: 250 mm or more
: Top discharge(open in principle)
: Front inlet(open in principle)
: Rear inlet(open in principle)
Front
service space
<Top View>
<Side View>
Service Manual 45
Installation
When inlet air enters from right and left sides of unit
A : 750 mm or more
B : 250 mm or more
C : 150 mm or more
Rear
Front
<Top View>
<Side View>
B
A : 750 mm or more
B : 250 mm or more
A : 45 or more
B : 200 mm or more
C : 250 mm or more
Installation
Rear
Front
Rear
Front
Service Manual 47
Installation
Outdoor Unit_AUUH1008C
1. Individual installation
Basic Space required
A space of at least 250 mm is nessary at the back for inlet air. Tacking servicing, a space of about 750 mm
should be provided at the front.
C
Rear
A
B
C
D
E
: 750 mm or more
: 250 mm or more
: Top discharge(open in principle)
: Front inlet(open in principle)
: Rear inlet(open in principle)
Front
A
service space
<Side View>
<Top View>
When inlet air enters from right and left sides of unit
A : 750 mm or more
B : 250 mm or more
C : 150 mm or more
Rear
Front
<Top View>
<Side View>
B
A : 750 mm or more
B : 250 mm or more
Installation
When there is an obstructure above the unit
D : 1000 mm or more
E : Air outlet guide (procured at the site)
F : 250 mm or more
A : 45 or more
B : 200 mm or more
C : 250 mm or more
A
D
: Open state
: 750 mm or more
: 250 mm or more
: 250 mm or more
Rear
A
B
C
D
Front
Space required for collective installation and continuous installation : When installing several
units, leave the space between each block as show below considering passage for air and people.
Rear
Front
Service Manual 49
Installation
AUUH728C
Installation foot
Individual installation
7002
50
5002
250
556
5002
5002
250
556
5002
AUUH1008C
Installation foot
Individual installation
7002
90
9002
9002
250
556
9002
250
556
9002
Installation
Lifting Method
When carrying the unit suspended, pass the ropes under the unit and use the two suspension points each at
the front and rear.
Always lift the unit with ropes attached at four points so that impact is not applied to the unit.
Attach the ropes to the unit at an angle of 40 or less.
Use two ropes at least 7 m long.
A 40 or less
A 40 or less
Caution:
Be very careful to carry product.
Do not have only one person carry product if it is more than 20 kg.
PP bands are used to pack some products. Do not use them as a mean for transportation because they are
dangerous.
Do not touch heat exchanger fins with your bare hands. Otherwise you may get a cut in your hands.
Tear plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic packaging
bag may suffocate children to death.
When carrying in outdoor unit, be sure to support it at four points. Carrying in and lifting with 3-point support
may make outdoor unit unstable, resulting in a fall of it.
Service Manual 51
Installation
L2
L2
L3
L3
L4
Outdoor
Unit
L4
L5
h1
h2
L5
b
Indoor Unit
L1
Main (L1)
AUUH488C
AUUH728C
Branch
L2
L3
L4
h1
h2
L5
b
Main (L1)
AUUH1008C
Pipe Length(m)
Total(Main+Branch)
Main Pipe(L1)
Branch Pipe----Total
Each
In out (h1)
In-In (h2)
L1+L2/L3/L4/L5
Indoor-Indoor_(b)
Spec.
110
50
60
15
30
1
65
10
When installing the branch pipe, direction and angle of installation is not limited.
Take care so that burrs and foreign material may not enter into the cutting surface when connecting.
Dont use the liquid pipe by too bending or twisting.
Installation
Piping Connection
1. Form the piping according to its routing. Avoid bending and bending back the same piping point more than
three times. (This will result in hardening the pipe.)
2. After deforming the piping, align centers of the union fitting of the indoor unit and the piping, and tighten them
firmly with wrenches.
3. Connect pipe to the service valve or ball valve which is located below the outdoor unit.
4. After completing the piping connection, be sure to check if there is gas leakage in indoor and outdoor connection.
Welding
Elbow
Welding
Elbow
AUUH7280
Welding
Elbow
AUUH10080
Elbow
AUUW4860AUUW6060
Service Manual 53
Installation
Trio
Quartet
Model
AUUH488C
0.07
Note: If total additional charge value after calculation comes out to be negative, then do not consider additional
charge.
CAUTION:
Rated performance for refrigerant line length of:7.5m
Capacity is based on standard length and maximum allowance length is on the basis of
reliability.
Improper refrigerant charge may result in abnormal cycle.
Oil trap should be installed every 10 meters.
2. AUUH728C/AUUH1008C
For additional charging method, see below table.
Synchro
Duo
Trio
Quartet
Refrigerant Branch
Pipe (mm)
6.35
0.03 kg/m
9.52
0.05 kg/m
Note: If total additional charge value after calculation comes out to be negative, then do not consider additional
charge.
CAUTION:
Rated performance for refrigerant line length of:7.5m
Capacity is based on standard length and maximum allowance length is on the basis of
reliability.
Improper refrigerant charge may result in abnormal cycle.
Oil trap should be installed every 10 meters.
Installation
Branch Kit
1. Type of branch pipe
Separately use a branch pipe depending on indoor capacity for installation.
Unbalance type of branch pipe must be connected depending on large capacity or small capacity.
Indoor Classification
2 UNIT
3 UNIT
4 UNIT
Remark
Capacity Ratio(%)
50:50 (1:1)
40:60 (2:3)
20:40:40 (1:2:2)
25:25:50 (1:1:2)
33:33:33 (1:1:1)
25:25:25:25(1:1:1:1)
Model Name
PMUB11A
PMUB23A
PMUB122A
PMUB112A
PMUB111A
PMUB1111A
Unbalance type
Unbalance type
Unbalance type
Insulation
Gas pipe
Liquid pipe
Band
Socket
Insulation(Gas pipe)
Insulation(Liquid pipe)
(15.8819.05)
Procure other parts than those specified in this manual in the scene
No. parts are used for connection of 48/60k indoor unit.
(I.D)
19.05(3/4)
9.52(3/8)
12.7(1/2)
6.35(1/4)
9.52(3/8)
(): inch
(Liquid pipe)
25.4(1)
12.7(1/2)
15.88(5/8)
9.52(3/8)
12.7(1/2)
Service Manual 55
Installation
Band 7
Insulation 6
Insulation 4
Vinyl Tape
Insulation 6
Vinyl Tape
Band 7
Band 7
Insulation 5
Vinyl Tape
Installation
Wiring Connection
1. All wiring must comply with LOCAL REGULATIONS.
2. Select a power source that is capable of supplying the current as required by the air conditioner.
3. Feed the power source to the unit via a distribution switch board designed for this purpose.
4. The terminal screws inside the control box may be loose due to vibration during transport.
Check the screws for loose connection.
(Running the air conditioner with loose connection can overload and damage electrical components.)
5. Always ground the air conditioner with a grounding wire and connector to meet the LOCAL REGULATION.
Terminal Block
(Outdoor Unit)
Power
Input
Terminal Block
(Indoor Unit)
AUUH488C/AUUH728C/AUUH1008C
CAUTION
The power cord connected to the outdoor unit should be
complied with the following specifications (Rubber
insulation, type H05RN-F approved by HAR or SAA).
NORMAL
CROSS-SECTIONAL
AREA 5.5mm2
GN
/YL
20
mm
GN
/YL
20
mm
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer of its service agent.
WARNING:
Make sure that the screws of the terminal are free from looseness.
Service Manual 57
Installation
Auto addressing
Auto addressing work should be done for simultaneous operation.
Addressing work assigns address to each Indoor Unit.
When firstly installing product or replacing the Indoor Unit PCB.
AUUH488C/AUUH728C/AUUH1008C
Table.a ZONE SW1 Setting
ZONE SW1
Main PCB
LED01T
TEST_SW1
1
x
2
0
3
0
4
0
1
x
2
1
3
0
4
0
1
x
2
1
3
1
4
0
1
x
2
1
3
1
4
1
JIG_SW
ZONE SW1
2(Duo)
3(Trio)
1. JIG_SW Setting
Check the JIG_SW to the right, or not set the JIG_SW to
the right.( A )
2. ZONE SW1 Setting
Set the ZONE SW1 as below Table.a ( B )
S/W1 is not used.
1 means S/W up.
0 means S/W down.
4(Quartet)
Installation
1. Turn on the power of the unit by the installed remote controller, a wire or a
wireless remote controller. When an installation professional installs it,
only one wire remote controller is installed except the location with only the
Convertible combination installed (using the wireless remote controller)
when completing the indoor unit setting (Cassette ceiling top/bottom, Duct
E.S.P. value).
2. After setting the desired operation mode and temperature and then starting
the unit to operate, wait for 2 or 3 seconds.
3. The remaining unites simultaneously starts with the same setting mode to
operate.
4. If you want to stop operating, the remaining units are operated to stop in 2
or 3 seconds by the installed remote controller. (However, the location with
only the Convertible combination is operated by the wireless remote controller.)
5. For more information about how to operate the remote controller, refer to
the previous pages.
Service Manual 59
Installation
Test running
1. PRECAUTIONS IN TEST RUNNING
The initial power supply must provide at least 90% of the rated voltage.
Otherwise, the air conditioner should not be operated.
CAUTION
For test run, carry out the cooling operation firstly even during heating season. If
heating operation is carried out firstly, it leads to the trouble of compressor. Then
attention must be paid.
Carry out the test run more than 5 minutes without fail.
(Test run will be cancelled 18 minutes later automatically)
The test run is started by pressing the room temperature checking button and down timer button for 3 seconds at the same time.
To cancel the test run, press any button.
M5......196N.cm{20kgf.cm}
M8......588N.cm{60kgf.cm}
Thermometer
Operation
Operation
Function of control
1. MAIN UNIT FUNCTION
DISPLAY
Operation Indicator
On while in appliance operation, off while in appliance pause
Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on)
Sleep Timer Indicator
On while in sleep timer mode, off when sleep timer cancel or appliance operation pause
Timer Indicator
On while in timer mode (on/off), off when timer mode is completed or canceled
Defrost Indicator
Off except when hot start during heating mode operation or while in defrost control
Service Manual 61
Operation
While compressor on, the indoor fan is off when the indoor pipe temp. is below 20C, when above 27C , it
operates with the low or setting speed. When the indoor pipe temp is between 20C and 27C, it operates
with Super-Low(while in sleep mode, with the medium airflow speed).
While compressor off, the indoor fan is off when the indoor pipe temp is below 33C, when above 35C , it
operates with the low airflow speed.
While in defrost control, the indoor is outdoor fans are turned off.
Defrost Control(Heating)
Defrost operation is controlled by timer and sensing temperature of outdoor pipe.
The first defrost starts only when the outdoor pipe temperature falls below -6C after 35 minutes passed
from starting of heating operation and more than 4 minutes operation of compressor.
Defrost ends after 12 minutes passed from starting of defrost operation when the outdoor pipe temperature
rises over 15C even before 12 minutes.
The second defrost starts only when the outdoor pipe temperature falls below -6C after 35 minutes passed
from ending of the first defrost and more than 4 minutes operation of compressor.
Fuzzy Operation
When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed
since the operation off, the operation mode is selected.
When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and
only the indoor fan is operated for 15 seconds. Then an operation mode is selected according to the intake
air temp at that moment as follows.
24C Inatake Air Temp
Fuzzy Operation for Cooling
21C Inatake Air Temp<24C
Fuzzy Operation for Dehumidification
Inatake Air Temp<21C
Fuzzy Operation for Heating
If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for
10 sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated.
1) Fuzzy Operation for Cooling
According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5C or more
below the setting temp, the compressor is turned off. When 0.5C or more above the setting temp, the compressor is turned on.
Compressor ON Temp
Setting Temp +0.5C
Compressor OFF Temp
Setting Temp + 0.5C
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26C Intake Air Temp
25C
24C Intake Air Temp<26C
Intake Air Temp + 1C
22C Intake Air Temp<24C
Intake Air Temp + 0.5C
18C Intake Air Temp<22C
Intake Air Temp
Intake Air Temp<18C
18C
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature.
Operation
2) Fuzzy Operation for Dehumidification
According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5C or more
below the setting temp, the compressor is turned off. When 0.5C or more above the setting temp, the compressor is turned on.
Compressor ON Temp
Setting Temp + 0.5C
Compressor OFF Temp
Setting Temp+0.5C
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26C Intake Air Temp
25C
24C Intake Air Temp<26C
Intake Air Temp+1C
22C Intake Air Temp<24C
Intake Air Temp+0.5C
18C Intake Air Temp<22C
Intake Air Temp
Intake Air Temp<18C
18C
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy operation, the airflow speed of the indoor fan repeats the low airflow speed or pause as in
dehumidification operation.
3) Fuzzy Operation for Heating
According to the setting temperature selected by Fuzzy rule, when the intake air temp is 3C or more above
the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned on.
Compressor ON Temp
Setting Temp
Compressor OFF Temp
Setting Temp + 3C
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
20CIntake Air Temp
Intake Air Temp + 0.5C
Intake Air Temp<20C
20C
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to
the intake air temperature and the setting temperature.
On-Timer Operation
When the set time is reached after the time is input by the remote control, the appliance starts to operate.
The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached.
If the appliance is operating at the time set by the timer, the operation continues.
While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature.
Off-Timer Operation
When the set time is reached after the time is input by the remote control, the appliance stops operating.
The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached.
If the appliance is on pause at the time set by the timer, the pause continues.
Service Manual 63
Operation
Off-Timer <=> On-Timer Operation
When the set time is reached after the on/off time is input by the remote control, the on/off-timer operation is
carried out according to the set time.
Operation
Forced Operation
To operate the appliance by force in case that the remote control is lost, the forced operation selection
switch is on the main unit of the appliance to operate the appliance in the standard conditions.
When the power is supplied while the slide switch is on the forced operation position, or when the slide
switch position is switched to the Auto Restarting (or test operation) position or switched from the remote
control position to the forced operation position while the power is on, the forced operation is carried out.
When the slide switch position is switched from the forced operation position to the Auto Restarting position
or the remote control position, the forced operation is canceled and the appliance stops operating.
In the forced operation mode, the indoor fan is operated at low speed for around 15 sec and then the operation condition is set according to the intake air temperature as follows.
24CIntake Air Temp
Cooling Mode Operation, 22C, High Speed
21CIntake Air Temp<24C
Dehumidification Operation, 23C, High Speed
Intake Air Temp<21C
Heating Mode Operation, 24C, High Speed
Service Manual 65
Operation
CST Type
Operation ON/OFF
(Cooling
(Heating
model only) model only)
)
)
LO (Low)
MED (Med)
HI (High)
JET
Down to 18C
Up to 30C
Heating
Cancel
Weekly Program
Program
Week
Holiday
Min
Down to 16C
Up to 30C
AUTO
Operation
Duct Type
Operation ON/OFF
(Cooling
(Heating
model only) model only)
)
)
LO (Low)
MED (Med)
HI (High)
Down to 18C
Up to 30C
Heating
Down to 16C
Up to 30C
Cancel
Weekly Program
Program
Week
Holiday
SET/CLR
Hour
Min
Service Manual 67
Operation
Convertible
Operation ON/OFF
)
)
(Med)
(High)
(CHAOS)
Heating
Down to 16C
Up to 30C
: (High:39C
Low:11C)
Temperature Setting
TEMPERATURE
LOW
HIGH
Cooling
Down to 18C
Up to 30C
JET COOL
PLASMA(Optional)
Timer Selection
ON
OFF
ON
Timer Setting
SET
Timer Cancel
CANCEL
Sleep Operation
: 1, 2, 3, 4, 5, 6, 7, Off Timer
Airflow Direction Control
Air Circulation
2nd F
Reset
Operation
Signal transmitter
1. START/STOP BUTTON
Operation starts when this button is pressed
and stops when the button is pressed again.
2. OPERATION MODE SELECTION
BUTTON
Used to select the operation mode.
(Heat Pump)
(Cooling Only)
5
6
5. JET COOL
Used to start or stop the speed cooling/heating.
(Speed cooling/heating operates super high fan
speed.)
3
4
2
7
11
8
13
10
CANCEL
ON
OFF
SET
AUTO CLEAN
12
15
14
Flip-up door
(opened)
Operation Mode
Cooling Operation
Auto Operation
Cooling Model(
For the convertible type of air conditional, jet cool mode does not operate.
Service Manual 69
Operation
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
SUB FUNCTION
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
3
17
10
11
12
13
14
15
2
Timer
Cancel
Program
Week
5
Holiday
Plasma
Set/Clr
Hour
Min
RESET
16
18
Cooling Model
4
7
8
9
1. Operation display
Displays the operation conditions.
2. On/Off Button
Operation starts when this button is pressed, and
stops when the button is pressed again.
Display temperature can be different from actual room temperature if the remote controller is installed at
the place where sun-rays are falling directly or the place nearby heat source.
Operation
AUTO SWING
OPERATION
SET TEMP
Room Temp
Timer
Operation unit
3
Signal Receiver
5
8
9
10
11
12
13
03
SUB FUNCTION
HI
MED
LO
Time
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
2
Timer
Cancel
Program
Week
6
7
4
Holiday
Plasma
SET/CLR
Hour
Min
RESET
14
1. Operation display
Displays the operation conditions.
2. On/Off Button
Operation starts when this button is pressed, and stops
when the button is pressed again.
3. Set Temperature Button
Used to set the temperature when the desired temperature is obtained.
4. FAN Operation Button
Used to circulate room air without cooling or heating.
5. Electric Heater Button(optional)
Used to set the Electric Heater.
6. Fan Speed Button
Used to set desired fan speed.
7. Operation Mode Selection Button
Used to select the operation mode.
Auto Operation Mode.
Cooling Operation Mode.
Soft Dry Operation Mode.
Heating Operation Mode.(except cooling model)
8. Timer Cancel Button
Used to cancel the timer.
15
16
17
Display temperature can be different from actual room temperature if the remote controller is installed at
the place where sun-rays are falling directly or the place nearby heat source.
Service Manual 71
Operation
1. Two Thermistor System
(1) Open the rear cover of the wired remote-controller to set the mode.
(2) Select one of three selectable modes as follows.
Position 1: The room temperature is controlled by the thermistor of the main body.
Position 2: The room themperature is controlled by the thermistor of the wired remote-controller, control
the temperature according to the position of wired remote-controller.
Position 3: The room temperature is controlled by lower temperature between the temperature of main
body and of remote-controller sensor.
(3) Move the slide switch to set position.
Room Temp. sensor
Slide switch for 2 Thermistor
R13H
TH
OP2
R14H OP3
SW TH
REMO
MAIN
2TH
OP5R16H
CO1H
REMO
MAIN
2TH
OP4
R15H
OP7
R18H
R17H
OP6
LO
C070
Position 2
Position 1
Position 3
R12H
OP1
R19H
R11H
STAND
R03S
HI
R04S
R01S
R02S
SW
HIGH
Procedure
1. Choose the selectable position in the table after measuring the height of ceiling.
Ceiling height
more than 3.3m
2.7~3.3m
less than 2.7m
Remark
Manufactured in
standard mode
2. In the case of changing the height as "high" or "low", open the rear cover of the wired remotecontroller.
3. Move the slide switch to the set position.
Slide switch for 2 Thermistor
TH
Low ceiling
Standard
(Default)
High Ceiling
Lo
R13H
OP2
R14H OP3
SW TH
STAND
REMO
MAIN
2TH
Hi
R12H
CO1H
OP1
R19H
R11H
OP7
R18H
R17H
OP6
C070
LO
STAND
R03S
HI
R04S
SW
HIGH
R02S
R01S
OP5R16H
OP4
R15H
Operation
3. E.S.P.(External Static Pressure) Setting (Duct type)
(1) Open the rear cover of the wired remote-controller to set the mode.
(2) Select one of three selectable modes as follows.
TH
R14H OP3
SW TH
V-L
R13H
OP2
REMO
MAIN
2TH
CO1H
OP1
R19H
R11H
OP5R16H
OP4
R15H
OP7
R18H
R17H
F-H
OP6
LO
C070
V-H
R12H
STAND
R03S
HI
R04S
HIGH
R01S
R02S
SW
CAUTION:
Select the position after checking duct work and E.S.P of the unit.
Maunfactured in the position F-H.
Service Manual 73
Operation
4. How to Set E.S.P?
Procedure of RPM change:
Ex) External Static pressure is 6mmAq for 36k.
To protect the unit, compressor is designed to be off during E.S.P. setting.
OPERATION
SET TEMP
FAN SPEED
Room Temp
Time
Timer
Operation unit
On Off
Set no. Time 01
03
Program set
05
07
09
11
13
15
17
19
21
23
Push the "Timer" and "Wind" button simultaneously for more then 3 seconds.
Timer
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
Operation unit
03
SUB FUNCTION
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
SUB FUNCTION
HI
MED
LO
Program set
05
07
09
11
13
15
17
19
21
23
OPERATION
SET TEMP
FAN SPEED
Room Temp
Time
Timer
Operation unit
On Off
Set no. Time 01
03
SUB FUNCTION
HI
MED
LO
Program set
05
07
09
11
13
15
17
19
21
23
Note: The range of selection is from 1~254. Since, the display is two Digit only.
If the range selection is above 100 then the third digit will appear in the screen as shown.
Shift the fan speed mode by pressing the fan speed button.
And then, Adjust numbers of next steps by repeating the stage 3.
(In this example, the numbers are "235" and "243" respectly)
the "Timer" and "Wind" button simultaneously for more than 3 seconds.
5 Push
Then, Wind Data is memorized by the EEPROM of the main PCB.
AUTO SWING
OPERATION
SET TEMP
Room Temp
Time
Timer
Operation unit
03
SUB FUNCTION
HI
MED
LO
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Operation
[Table. 1]
Static Pressure(mmAq)
Model Name
18K
24K
30K
36K
48K
60K
Step
CMM(CFM)
High
16.5(583)
235
230
225
215
180
Med
14.5(512)
245
238
235
230
215
Low
13(459)
254
252
248
245
240
High
18(636)
220
205
190
50
Med
16.5(583)
235
230
220
200
100
10
12
14
15
190
180
160
Setting Value
Low
14(494)
250
240
235
230
210
High
26.5(936)
153
150
150
148
130
Med
23(812)
173
173
175
175
170
155
Low
20(706)
190
190
190
190
190
190
High
32(1130)
230
230
225
220
150
Med
29(1024)
240
238
237
235
230
220
Low
26.5(936)
245
245
243
243
240
240
High
40(1412)
230
225
220
215
205
200
Med
35(1235)
250
245
240
235
230
220
215
210
200
Low
30(1059)
255
255
255
250
245
240
235
230
225
High
50(1766)
185
180
174
162
154
140
90
Med
45(1589)
210
205
199
191
189
180
155
138
110
Low
40(1423)
230
225
219
215
210
205
193
180
171
Note: 1. Be sure to set the value refering table 1. Unexpected set value will cause mal-
function.
2. Table 1 is based at 230V. According to the fluctuation of voltage, air flow rate
varies.
Service Manual 75
TOTAL On button
Operate all linked units sequentially.
Electrical wiring
PICTORIAL VIEW OF THE CONNECTION
Outdoor
Outdoor unit
unit
PI485
: PNF-P14A0M
MAIN PCB
L
PI485
MAIN PCB
Control Box
CN_CENTRAL
MAIN PCB
N
CN_CENTRAL
10
G
A
B
PI485
CENTRAL
CONTROL
UNIT
VCC
GND
C
D
CN OUT
INDOOR UNIT
INDOOR UNIT 2
INDOOR UNIT 3
OUTDOOR
MAIN PCB
INDOOR UNIT 4
INDOOR UNIT 5
GND
Vcc
INDOOR UNIT 6
CN-POWER
GND
BUS
B
BUS
A
CN-COM B
CN-POWER
CN-COM A
S2
S1
GND
S4
LED2
LED4
LED3
+10V
IC1P
S5
S6
LED7
LED8
S3
LED5
C GND VCC
Outdoor
Outdoor unit
unit
S9
LED9
LED10
LED13
Group Number 0
Master Mode
LED14
S10
LED12
LED11
S14
TX1
S12
S11
S15
LED15
S16
LED16
PWB:6870A10001A
ASM:6711A20005E
S15
+
LED17
S18
ON KSDO4H
L1 2 3 4
S19
VCC
CENTRAL
GND
CONTROL
C
UNIT
D
Service Manual 77
OUTDOOR
MAIN PCB
INDOOR UNIT 4
GND
Vcc
BUS
B
BUS
A
Master
CN-POWER
GND
CN-COM B
CN-POWER
CN-COM A
S2
S1
DIP SWITCH
S4
LED2
LED4
LED3
GND
IC1P
S5
S6
LED5
+
+10V
S9
LED9
+
LED8
S10
S14
TX1
1. Adhere the PI485 Module(For connecting central control) to the Control Box.
2. Connect the PI485 Module to central control.
3. In the case of connecting two more than central control, set the Master/Slave mode
and then connect each communication lines(C,D) <Refer to above fig>.
*Special purcharse: Central control(P/No.:4995A20105F),
PI485 Module(PNF-P14A0M)
* It can be added to 15 Central controls for the slave control.
LED12
S15
S16
LED16
LED15
LED14
S3
S12
S11
+
LED11
LED10
+
LED13
+
LED7
PWB:6870A10001A
ASM:6711A20005E
C GND VCC
LED17
ON KSDO4H
L1 2 3
Outdoor unit 1
S18
S15
S19
Master Mode
Group Number 0
INDOOR UNIT 1
INDOOR UNIT 2
INDOOR UNIT 3
OUTDOOR
MAIN PCB
Note
INDOOR UNIT 4
INDOOR UNIT 5
INDOOR UNIT 6
GND
Vcc
BUS
B
BUS
A
001
C
CN-POWER
GND
CN-COM B
CN-POWER
CN-COM A
S2
S1
S4
LED2
IC1P
S5
S6
S9
LED9
C GND VCC
LED13
LED14
S15
TX1
Indoor No.
S12
LED12
LED11
S14
Group No.
S3
LED8
S11
S16
LED16
LED15
PWB:6870A10001A
ASM:6711A20005E
S15
+
LED17
Outdoor unit 2
S10
LED10
+
LED7
LED5
Slave
LED4
LED3
GND
+10V
DIP SWITCH
S18
ON KSDO4H
L1 2 3
S19
Master Mode
Group Number 0
Selection of product
unit type
ON KS DO 4H
L1 2 3
ON KS DO 4H
Function of LG Network
- It is possible to connect the network of LG air conditioners and to connect various contents of the network
system, which is simple, deluxe and PC central control.
- Please refer to "LG Control System Manual" about the detail functions and the products possible to network.
- As the Interface for networking, PNF-P14A0M/R/C is applied.
AUTO SWING
OPERATION
SET TEMP
Room Temp
Timer
Operation unit
03
SUB FUNCTION
HI
MED
LO
Time
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
3
17
10
11
12
13
14
15
Timer
Program
6
4
Holiday
Plasma
7
8
9
Set/Clr
Hour
Cancel
Week
Ex)
Min
RESET
16
18
1) Press 5(Jet Cool) & 13(Reset) key at the same time more
than 3 seconds then
"Address Setting Mode" starts.
2) Set the address of indoor unit by using
"Temperature setting" key.
Range of address : 00 ~ FF
6
3
Ex)
4
2
7
11
8
13
14
10
CANCEL
ON
OFF
SET
AUTO CLEAN
9
16
12
15
Flip-up door
(opened)
2.
2. Address Monitoring
1) Press 6(Chaos Swing) & 13(Reset) key at the same time then "Address Monitoring Mode"
starts.
2) At the address monitoring mode, pressing 1(On/Off) key, The address that is set is displayed
on a display window of indoor unit.
* notice : The mothod of display and time is different according to indoor unit type.
3) If the remote control is reset, normal mode starts.
* Notice : Confirm that wired and wireless remote control are able to select the address or not.
Service Manual 79
Installation
CAUTIONS
Keep in mind
Dont operate with wet hands.
case bottom.
Installation Procedure
Vcc
C
GND
Wire Color
BLUE
Red
Brown
Yellow
2. After attaching the supplied wire to terminal, link the connecting wire.
If necessary, Cut the indicated part of front case to draw the lead wire.
Service Manual 81
It is possible to set 0~15 Group(Total 16 Groups). All the numbers on the rotary switch represent the different
Group Numbers. By changing the knob we can set rotary switch to the group number we want to control. The
above fig. Shows the control of group number 0. Similarly we can control all the 16 Groups.
Master Mode
Rotary Switch
Dip Switch
ON
Slave Mode
OFF
. ACCEASSORY PARTS
Central control and sub
Central Control(1EA)
PI485(PQNFP14A0M)
Wire Assembly 1
Screw(4EA)
Wire Assembly 2
Deluxe
Central control
CNU
PI485
PI485
Service Manual 83
Major Characteristics
1. Individual/Integrated Operation/Monitoring
You can identify operation status of the air conditioner, operation mode, wind quantity, wind direction, locking, temperature setting and error, etc by selecting the installed air conditioner through individual selection,
group selection or all selection. Individual setup and operation of the detailed functions are available.
Therefore, managing with Deluxe Central control installed at the control room at a building where a number
of air conditioners are installed, is a convenient way.
2. Group Management
Group management for the installed air conditioners is available. Group can be seperated by their nature,
location and size of each air conditioner which enables convenient use. In addition, allotment of respective
name to the setup group allows further intuitive management.
3. Self-diagnosis Function
The air conditioner installed can self-diagnosed its error status and then transmits the result to the central
control. Therefore, a rapid countermeasure against failure of the air conditioner allows easy management
and increases the usage life of air conditioner.
9. Mobility
A wireless radio system may be installed at the Deluxe Central control, it will control the Airconditioners
directly while going around the building with the wireless radio system and its self-battery function (100 m
where there is no obstacle).
12. Scalability
Scalability of the system is easy in case of additionally purchasing equipment since scalable slot such as
USB, Serial (RS-232c), PCMCIA, CF Type is prepared. This system is designed considering sufficient scalability in provision for special request by the customer.
13. Upgrade
Additional installation of a new program is available via the CF memory card and the existing program can be
upgraded to a new program. Using such upgrade function always enables to construct a modern type of
Central Control System.
Service Manual 85
PC Central control
Dedicate PC
Non-required
Required
Configuration
User S/W
Position of program
Download to i-GW
Installation
Built-in
256 sets1)
256 sets
Remote control
Available
Available
Available
Available
Schedule management
Available
Available
Available
Available
Available
Available
Users lock
Available
Available
Available
Upgrade
Available
Available
Available
Touch screen
Built-in
Built-in
Available (option)
Non-interruption device
System setup
Available(Configure file
modification)
System monitoring(overview)
Non-required
Main Body of Web Pad
Deluxe Central control
Separately add
Built-in
-
Requirements
2)
JVM (provided by MS)
Life
Semi-permanent
Semi-permanent
1) For the PC central control, installation set numbers may respond up to 1024 sets upon users request.
2) JVM (Java Virtual Machine) is basically installed at the Windows but some versions of Window XP may be
manually installed.
PQCSW501A0, PQCSW502A0
[ System Monitor ]
To check the ctual time status of all air conditioners.
PQCSW501A0, PQCSW502A0
[ System Set-up ]
To manage the air conditioner through grouping and record setup
of group and installation position, etc.
PQCSW501A0, PQCSW502A0
[ Time Schedule ]
Setup of a weekly schedule for all, group and individual air
conditioner enabled operation of the system. Processing through
enlist of extra schedule for a year is available.
PQCSW502A0
Service Manual 87
System Configuration
Scenario 1 : In case of not using Internet access function
B part
A part
Product
Control System
Interface
Delux Central
Control
CNU
PI485
PI485
Cross UTP Cable
(Cross LAN Cable)
RS-485 Cable
PI485
PI485
Main Specifications
1. Control System
- Centralized control of maximum 256 indoor units
- Simple Touch PAD method
- GUI setting considering convenience of use
- Power failure compensation with independent Battery Built-in (Max. 2 hours)
2. CNU
- Combination of maximum 8 outdoor units
- 485 to Ethernet Converter Built-in
3. PI485
- 1 pcs per outdoor units
Note: - GUI(Graphic User Interface) may be changed without any notice, for improvement or options.
1 1
2 2
2
3
2
3
2
3
2
3
1
2
CN-TH4
CN-TH3
CN-TH2
CN-TH1
WCN-W
YL
W
V
U
NORMAL
LONG
12.1K,1%
2012
R15H
18K,1%
2012
R14H
18K,1%
2012
R13H
R10H
1.5K,1%
2012
R09H
+5V
12.1K,1%
2012
R11H
50V
10uF
C01H
6.2K,1%
2012
50V
10uF
C02H
R12H
50V
10uF
C03H
6.2K,1%
2012
50V
C04H
10uF
20K
2012
R07P
R06P
R08H
R07H
R05H
R06H
R04H
R02H
R03H
R01H
+15V
R01H~R08H
1K 2012
+5V
C07H
R18P
C08H
C09H
C10H
C11H
+5V
C12H
G
A2
C01L
103
2012
+5V
2012
R01L
4.7K
2012
R02L
4.7K
FAN FG
C.T
+5V
L03D
12uH
C02N
102K
2012
P103/HEAT_SINK
93
P104/OUT_AIR
92
P106/SUCTION
90
P107/DISCHARGE1
89
P00/DISCHARGE2
88
P01/AN01
87
P02/AN02
86
+5V
JIG POINT
83
R14T
1K
2012
R04T
4.7K
82
81
P07/AN07
P04/AN04
P06/AN06
P14
P05/AN05
P91
INT5
INT4
INT3
AVcc
P10/AN0
Vref
7
8
P101/AN1
AVss
CLK1/P65
RST1/P64
P102/AN2
P105/PIPE
P03/AN03
CE/P50
P47 47
P21/AN21
P20/AN20
P22/AN22
P23/AN23
P24/AN24
P25/AN25
P26/AN26
P27/A7
Vss
Vcc2
P30/A8
P60
EPM/P24
P46 48
P32/A10
P31/A9
P33/A11
P82/INT0
P34/A12
P36/A14
P35/A13
P75/W
P40/A16
P37/A15
35
TXD0/P63
TXD-5
36
RXD0/P62
RXD1/P66
TXD1/P67
32
34
33
31
TXD-4
38
RXD-3
P26 39
RXD-4
P61 37
TXD-3
P25 40
RXD-2
P23 42
TXD-2
RXD-1
P21 44
TXD-1
P51 45
41
P44
4.7K
VDC
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
RX_Flash
R17T
4.7K
R16T
R15T
50
4.7K
TX_Flash
RXD-5
C02T
102K
2012
LED0
RX_JIG_S
TX_JIG_S
LED1
INT_HP
PSC F/Signal
Phase Control
DC Fan On/off
RY-PWR
RY-OIL/S
RY-C/COMP
RY-HOT GAS
RY-HEATER
RY-P/ICE
RY-4WAY
PTC
40 OHM
RY-PWR
G4A-1A-PE
G4A-1A-E
ZD03K
68V
R12K
1.5K
1/4W
1%
R13K
1.5K
1/4W
1%
ZD04K
68V
ZD05K
68V
R26K
1.5K
1/4W
1%
R27K
1.5K
1/4W
1%
ZD06K
68V
ZD07K
68V
R28K
1.5K
1/4W
1%
ZD08K
68V
R29K
1.5K
1/4W
1%
COMP
(single)
COMP_AC_IM
RY-C/COMP
AC (L1)
IC12K
TLP421(Dip)
IC11K
TLP421(Dip)
IC10K
TLP421(Dip)
IC09K
TLP421(Dip)
IC08K
TLP421(Dip)
IC07K
TLP421(Dip)
IC06K
TLP421(Dip)
IC05K
TLP421(Dip)
IC04K
TLP421(Dip)
IC03K
TLP421(Dip)
IC02K
TLP421(Dip)
IC01K
TLP421(Dip)
ENABLE3
ENABLE2
ENABLE1
RY-FAN(A)_L
RY-FAN(A)_H
PSC(On/off)
RY-FAN(B)_L
RY-FAN(B)_H
2012
680
R41K
2012
R40K
680
2012
680
R39K
2012
680
R38K
2012
680
R07K
2012
680
R06K
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
R25K
10K
RY-HOT GAS
G5NB-1A
AC (L)
R21K
1K 2012
+5V
+5V
R24K
10K
R20K
1K 2012
+5V
+5V
R23K
10K
R19K
1K 2012
+5V
+5V
R22K
10K
R18K
1K 2012
+5V
+5V
R11K
10K
R09K
1K 2012
+5V
+5V
R10K
10K
R08K
1K 2012
+5V
+5V
P43/A19
P42/A18
P45 49
2012
C06K
102K
C07K
102K
2012
C08K
102K
2012
2012
C09K
102K
C10K
102K
2012
C11K
102K
2012
C12K
102K
2012
C13K
102K
C14K
102K
2012
2012
C15K
102K
2012
C16K
102K
2012
C17K
102K
RY-OIL/S
G5NB-1A
+5V
46
RY-HEATER
G5NB-1A
RXD-6
TXD-6
P22 43
RY-4WAY
G5NB-1A
P41/A17
P74/W
P72/V
RY-P/ICE
G5NB-1A
CN-HOT GAS
CN-OIL/S
CN-HEATER
CN-4WAY
CN-P/ICE
2012
P73/V
P80/U
P81/U
P83/INT1
P84/INT2
P85/NMI
Vcc1
Xin
Vss
Xout
RESET
P86
CNVss
MITSUBISHI
M16C/62P Group
IC02A
P87
BYTE
P90
P92
P93
P94
P95
P96
R03N
20K
2012
INPUT VOLT
LOW-V
C09D
104
RESET
TXD-6
RXD-6
C03F
102
TX_JIG_PC
RX_JIG_PC
R07F
1K
R01B
0
4.7K
R01T
+5V
PWM
R02T
4.7K
Phase Freq
Q01C
KTC3198Y
(DIP)
INPUT VOLT
84
SCL
WP
Vcc
R18T
4.7K
C01C
103K
50V
C.T
R01C
12K,1%
+5V
+5V
OSC01B
4MHz
1
2
+5V
SDA
+5V
C02A
102
2012
R03A
1K
2012
CN-WRITER
TX-CC
RX-CC
R02C
47K,1/4
1%
C02C
102
R07C
1K,1/4
5%
R06C
2.7K,1%
+5V
10V(RN)
220uF
C01N
D02N
1N4148
91
C07H~C12H
C102*7
3
5
EEPROM
M24C08
R02N
1.65K 1%
1/6W
D01N
1N4148
R02V~R05V
47K,1/4W,5%
85
A1
A0
2012
R01A
4.7K
R02A
IC01A
100
2012
KIA7036P
3
C01A
3.3UF,50V
2
R01Z
R02Z
R03Z
R04Z
R05Z
R01Z~R06Z
100
2012
R06Z
D01V
1N4007
R05C
12K,1%
D02C
1N4148
+5V
R03C
10K,1%
R04C
4.7K,1/4
1%
C03C
25V,47uF
D01C
1N4007
C03A
104
BD01N
DF08M
R01V
47K,1W,5%
94
R19P
R12Z
4.7K
C06P~C08P
102M
R11Z
2K
+5V
4.7K
1/4W(or 2012)
R15P~R17P
R20P
R18P~R20P
1K 2012
R10Z
4.7K
C05Z C06Z
122
471
R01N
1K 1%
1/6W
IC01V
TLP421_BL
R06V
1K,1/4
5%
96
12
14
C05P
102
2012
IC01P
KIA339A
R09Z
2K
C04Z
122
BD01C
DF08M
+5V
R07V
10K
2012
CN-FAN(B)
95
R08P
R05P
R09P
C04P
104
2012
R10P
R14P
7.5K
1/4W 1%
R07Z R08Z
4.7K
2K
C03Z
471
R08V
1K
+5V
2012
R05P~R10P
50V
C05H
R01P~R04P
470K
1/2W 1%
R21P
7.5K
1/2W 1%
R11P~R13P
15K
1/4W 1%
C01P~C03P
331
10uF
R15Z
R14Z
R13Z
50V
+15V
10uF
C06H
4.7K
2012
OR1
R16H
1
2
3
SW1
PIPE LENGTH
5V : NORMAL
GND : LONG
C10Z
D03Z
D02Z
C08Z
D01Z
C07Z
C09Z
20
21
22
D01Z~D03Z : 1N4937
VB(W)
IN(WH)
VCC(WH)
23
18
17
16
15
19
13
C02Z
122
TRANS1
50Hz,DC12V
2012
C01V
102K
R06F
4.7K
1/4W
FAN FG
IN
VS(W)
VB(V)
VCC(VH)
VB(U)
VS(V)
IN(VH)
COM(H)
VCC(UH)
C12Z
C01Z
471
CT01N
Current Trans
INT_HP
2012
R05F
10K
CN-FAN(A)
VB
VCC
COM
VB
VCC
VB
IN
COM
AC(L)
AC(N)
AC (L1)
AC (L)
+15V
2012
R03F
4.7K
6.8V
ZD01F
CN-PRESS
VS
OUT
SPM2
FairChild
FSAM30SM60A
FSAM20SM60A
OUT
VS
C11Z
R16Z
20A :47,1/4W,1%
30A :56,1/4W,1%
R17Z
3.9K,1/4W,1%
C13Z 102K,2012
C14Z 104,2012
2012
C18Z
102
PSC F/Signal
Q03F
Q04F
C02F
10UF
/10V
C01F
103k
630V
P97
12
11
R20Z
390, 2012
2012
102
C08S
Q01F
FAN ON/OFF
2012
Q02F
R04F
5.1K
1/4W
GND
98
31
32
30
IN(UH)
VS(U)
14
10
+5V
2012
R19Z
20K
PSC On/Off
2012
R07S
20K
+15V
C05D
220uF
35V
1K
R01F
R02F
2012
Vcc
97
WCN-V
BL
WCN-U
RD
IN
COM
VCC
VFO
R18Z
2012
C17Z
102
4.7k
2012
C04S
680UF
400WV
+5V
R03S
1.2K
1/4W
2012
102K
C07S
50V
C08D
103
+5V
PWM
1K
FG
99
VS
OUT
CSC
RSC
CFOD
C03S
680UF
400WV
+15V
1
2
3
4
2012
LOW-V
R06S
4.7K
TLP421
IC02S
IC04D
C03D
220uF
10V
Vs
FAN
MOTOR(R)
100
VFO
C(FOD)
C(SC)
OUT(WL)
OUT(VL)
6
5
4
3
C16Z
47uF
50V
D01Y
1N4148
IC01S
TLP251
C02S
680UF
400WV
8
7
D01S
1N4007
+5V
R03Y
L02D
12uH
4.7K,1%
2K
1/2W
R02D
+15V
7805
50V
C07D
103
Q03F,04F
KRA106S(Chip)
DISCHARGE2
DISCHARGE1
PIPE
SUCTION
OUT AIR
HEAT SINK
YL
BL
RD
29
Nw
Nv
COM(L)
IN(UL)
IN(VL)
IN(WL)
COM(L) 2
1
C15Z
104Z
25V
2012
R02S
220
1/4W
2012
C05S
104
+15V
C01S
680UF
400WV
R01S
10k
1/4W
C06S
152J
C01Y
103K
50V,2012
C04D
470UF
35V
L01D
12uH
50V
C06D
103
Q01F,02F
KRC104S(Chip)
RY-FAN(B)-L
JQ1A-12V
C19Z
28
COM(L)
IN(UL)
IN(VL)
IN(WL)
OUT(UL)
VCC(L)
D1
D3
IGBT
GT50J102
C09S
152J
R04S
0.05 R05S
71.5k
1%
D01D
1N4937
400VAC
1.5uF
27
Nu
C09S
0.1uF
+120
R02Y
270K
1/2W
13
12
9
26
VCC
D2
D4
D1
1%
GND
OUT
R202
OUT
25 NC
24 NC
VDC
BD01S
RBV2506
RBV1506
D2
~ D3
R01Y
270K
1/2W
C101
R201
D201
+
C02D
470uF
25V
FAN
MOTOR(L)
RY-FAN(B)-H
JQ1A-12V
CN-COIL2
AC (N)
AC (L1)
BD02S
RBV1506
R102
D4
D101
R101
TNY
268
PC201
C01D
1000UF
35V
RY-FAN(A)-L
JQ1A-12V
CN-COIL1
IN
FB
L/P
Inv._COMP_BLDC
REACTOR
26.8mH/ 9A
11mH/ 14A
3
5
BP
C102
GND
RD
NC
NC
PC201
D202
102M
C10D
5
MOTOR
RY-FAN(A)-H
JQ1A-12V
H/P
GND
uRM1515-2B
5
YL
u-POWER MODULE
6
BL
CN-MOTOR1
BK
DC FAN
WH
+5V
CS-1
CS-2
CS-3
AC_COM
R15K
30K
1W
R14K
30K
1W
R16K
30K
1W
AC_COM
R17K
30K
1W
R30K
30K
1W
AC_COM
R31K
30K
1W
R32K
30K
1W
AC_COM
R33K
30K
1W
AC_COM
R34K
30K
1W
R35K
30K
1W
AC_COM
R36K
30K
1W
R37K
30K
1W
D03K
LED1
LED0
D03K~D08K
1N4007
D04K
D05K
D06K
D07K
D08K
C09J
1uF/ 275VAC
AC (N)
ER_CODE, INDICATOR
LED01G : RED_10
11
12
13
14
15
16
11
12
13
14
15
R01G
1.5K
+15V
LED02G
LED01G
R02J
20
1/4W,5%
J21~J26
C02M 104
2012
J27~J32
NF02J
RY-FAN(A)_L
RY-FAN(A)_H
PSC (On/off)
RY-FAN(B)_L
RY-FAN(B)_H
RY-4WAY
RY-HOT GAS
2012
C01M 104
RY-HEATER
RY-P/ICE
RY-OIL/S
RY-C/COMP
RY-PWR
R02G
17 1.5K
18
LED02G : GREEN_1
IC01M
KID65004AP
16
10
IC02M
KID65004AP
10
C07J
472M
C08J
472M
WCN_GND2
R03J
20
1/4W,5%
BK
R01K~R04K
11K/3W*4
R01M~R08M
68K
332M
C05J
C06J
332M
C04J
1UF
275VAC
D01K
1N4007
D02K
1N4007
QE
A0
A1
A2
A4
A3
A5
A6
A7
GND
QE
A0
A1
A2
A3
A4
A5
A6
A7
GND
QE
A0
A2
A1
A3
A4
A5
A6
A7
GND
ZNR01J,02J
SVC561
R04J
1M
1/2W
SURGE
DA-38-302MT-A21
R09M
10K
IC04M
74HC245AF
19
20
17
18
16
15
13
12
14
11
VCC
CS
CS-1
C03M
104
+5V
IC07M
KIA65084
18
13
14
17
12
B0
11
B1
10
16
15
B4
B3
B5
16
17
15
IC08M
KIA65084
C04M
104
+5V
18
B6
B2
CS-2
B7
VCC
CS
B0
B1
B2
14
17
18
19
20
R10M
10K
IC05M
74HC245AF
10
B3
13
16
12
15
11
10
B4
14
13
14
15
16
CS
B0
C05M
104
IC09M
KIA65084
B3
B2
11
12
13
14
15
16
17
B4
B5
275VAC
C01J
1uF/
Q01T
KRA105
C03T
102K
2012
2012
R07T
1K
10
B6
B1
+5V
12
RX_JIG_S
222M
C03J
222M
C02J
C02K
150uF/100V
+5V
R11T
1K
2012
20
R01J
WCN_GND1
1/4W,5%
AC_COM
B7
R12T
4.7K
18
CS-3
B7
12
VCC
B5
13
+5V
B6
11
17
18
19
20
R11M
10K
IC06M
74HC245AF
10
J51~J56
NF01J
R05K
50.5K/1W
36V,1W
ZD01K,02K
C01T
102K
2012
11
RX-CC
10
C01K
102/100V
J57~J62
BK
Schematic Diagram
Schematic Diagram
Electronic Control Device
1. Indoor Unit
(1) CassetteType
+15V
+15V
+5V
R06T
1K
+15V
+5V
R10T
1K
TX_JIG_S
TX_JIG_PC
RX_JIG_PC
R08T
10K
+5V
+5V
TX-CC
+5V
TX
RX
RX
TX
TX
RX
TX
RX
R09T
4.7K
R05T
4.7K
C06M~C11M
104
TX_FLASH
RX_FLASH
2012
FUSE
20A/250V
CN_LEV1
CN_LEV2
CN_LEV3
CN_LEV4
CN_LEV5
CN_CENTRAL
CN_FLASH
CN_JIG_S
CN_JIG_PC
CN_LEV6
2 2
3 3
2 2
3 3
2 2
3 3
CN-COM
4
5
2 2
3 3
WCN_P(L)
BR
CN-CP(N)
CN-CP(L)
4
5
WCN_P(N)
BL
LEV1
LEV2
LEV3
LEV4
LEV5
LEV6
C4
TB2
C4
C3
C3
C2
C1
C2
C1
GND GND
BK
WH
GR/YL
AC-POWER
AC220~240V/50,60Hz
TB1
Service Manual 89
CN-OUT
250V/
T3.15A,3A
ZNR01J
INR14D561K
M_RTX
C03J
10nF
275V
AC_L
RY-LOUV
RY-D/PUMP
RY-HEATER
RY-4WAY
RY-OUTFAN
RY-COMP
SIGNAL
NEUTRAL
LIVE
CN-POWER
RY-4WAY
RY-OUTFAN
RY-HEATER
CN-D/PUMP
Drain
Motor
CN-LOUVER
1
3
RY-L
RY-M
5V
AC_N
NTC01D
10D-9
C01D
10uF/
400V
IC02M
KID65004AF
DC310V
ZD01D
P6KE200A
D02D
UF4005
BP
EN
S/Trans
6,7
C05D
681
C06D
470uF/35V
D03D
UF5402
4,5
IC02D(TLP521)
12V
L01D
3.3uH
R04D
39
C07D
330uF/35V
R03D
150
P75
64
C03D
103
P74
5
4
TNY
255P
2 1
P76
ZD02D
11V
P77
C04D
103/250VA
1
63
P73
62
59
60
61
P70
P71
P72
2
P01
P00
4
P02
3
5
P03
57
6
(AIN7)/P67
58
P04
VDD
P05
55
54
(AIN5)/P65
56
(AIN4)/P64
(AIN6)/P66
P07
P06
P10(INT0)
(AIN3)/P63
9
11
10
P11(INT1)
51
52
53
12
P12(INT2/TC1)
(AIN2)/P62
13
(AIN1)/P61
C09D
220uF/50V
C11D
223/1KV
C12D
103/1KV
C10D
103
DC 12V
STEP M
5V
IC02M
KID65004AF
IC03D
KID78L05BP
I
O
7805
C08D
104
HEATER
4WAY
OUTFAN
COMP
A/C
STEP M4
5V
OPTION6
OPTION5
OPTION3
OPTION4
OPTION2
PIPE TH
ROOM TH
49
P13(DVO)
VARF
14
P14(PPG)
GND
OPTION 1
P15(TC2)
48
50
15
VASS
(AIN0)/P60
16
P16
SB3
17
S_B3
47
SB2
SB1
SB0
CC RX
S_B1
S_B0
_RX
R05H
12.1K
1%
R06H
12.1K
1%
R03H
12.1K
1%
R04H
12.1K
1%
5V
R02H
6.2K R01H
1% 12.1K
1%
M_RTX
M_RTX
CN-PIPE
D12K
1SR139-400
C01U
103
12V
SI1
SO1
IC11K(TLP621)
R14K
1K
5V
R01C
200K/2W
R02C
1K
R11K
10K
C11K
102
Q11K
KRC104M
RX
Multi_RX
DC 5V
D02K
2
1
50/60Hz
DC12V
3
Signal
2
GND
1
CN-REMO
L02K
L03K
TX Multi_TX
R16K
10K
C03K
102
5V
DAN212K
5V
Q01C
R06C
10K
R04C
4.7K
R05C
1K
C01C
103
R03C
10K
KRA104M
Q04K
C05K
C04K C06K
104 103
4.7K
R02K
L01K
D01K
DAN212K 100nH
12V
IC01C
C02K
102
Q03K
KRC104M
R12K,1K
DC 5V
DC 5V
12V
Q02K
KRC104M
KRA104M
Q01K
AC_N
AC_L
C01K
102
1K
R01K
5V
IC12K(TLP627)
_RX
_TX
R13K
1.5K
PLC_SEL
Multi_TX
GND
GND
Multi_RX
5V
SCK1
12V
CS0
5V
CS1
R15K
82K/3W
D11K
1SR139-400
CN-ROOM
5V
CN_ZONE
CN_M C
2
3
_RX
12V
5V
R07H
12.1K
1%
R08H
12.1K
1%
12V
5V
GND
_TX
C02U
103
40
R01U
10K
5V
Multi_TX
39
(SCK2)/P45
38
GND
(SO1)/P44
37
Multi_RX
XOUT
(SI1)/P43
36
_TX
25
VSS
(SCK)/P42
35
CC TX
S_B2
P54
45
P17
(PWM/PDO)/P52
18
(INT4/TC4)/P51
P53
TEST
44
P20(INT5/STOP)
P21(XTIN)
3,7,8
IC01D
TNY255P
DC 12V
STEP M5
MED
D/PUMP
Q 4
20
P22(XTOUT)
42
46
21
41
19
GND
22
(SI2)/P46
(SO2)/P47
26
P30
NC
43
NC
XIN
RESET
27
P31
NC
(INT3/TC3)/P50
NC
23
XOUT
XIN
RESET
24
PHASE
C02L
681
REMO
FREQ
IC01M
KID65004AF
LOW
HIGH
LOUVER
STEP M2
R02E
20
EERROM
VCC
DU
ORG
5 VSS
STEP M3
5V
STEP M
DC 12V
50/60Hz
REMO
BZ01E
R01E
1K
R01L
10K
R02L 1K
REMO
STEP M
STEP M
DC 12V
R01J
D01D
1M,1/2W 1N4007
C02J
100nF
275V
NF
NF01J
22mH/3A
C01J
100nF
275V
R01B
1.0M
28
P33
P32
34
29
NC
33
SO1/PLC
30
P34
NC
SI1/MULTI TX
31
P35
SCK1/MULTI RX
NF01M
R01A 1K
OSC01B
8.00MHZ
LED1
LED2
32
CSO
Louver
Motor
4
SSR
RY-H
C02A
102
4
5
5V
CN-DISP
LED4
LED3
LOUVER
FLOAT
CSI
NF01M
ZNR01M
R02A 10K
C01A
KIA7036P
2
3.3uF
/50V
R03L 1K
R04L 1K
5
6
7
6
7
1K
R01F
5V
1K
C01F
103
R02F
C02F
103
2
3
IC01A
3.6V
DISPLAY
LED1
LED2
R05L 1K
LED3
R06L 1K
LED4
CN-MOTOR1
FAN
MOTOR
CN-MOTOR2
FAN
MOTOR
5V
GND
Vcc
Vout
PRE AMP
TFMS-2380B
Force
SW
CN-LOUVER
CN-FLOAT
Schematic Diagram
Telecontrol
HVB
CN-12V
CN-CONT
CN-HVB
12V
12V
12V
DC12V
DC 5V
DC 5V
R06T,10K
5V
+ C09D
220
10V SD
C08D
103
50V
O
7805
IC04D
S78DL05L 1W
I
R05T,10K
C07D
104
50V
12V
HVB OUT
DC 5V
C02L
4.7
50V
R01G,330,1/4W
R02G,330,1/4W
R03G,330,1/4W
R04G,330,1/4W
DC 12V
FORCE
RECEIVER
Option
CN-CC
CN-U/D1
CN-U/D2
CN-LEV
LED1
LED2
LED3
WH YL OR BL BR RD
PRE AMP
ASSY
TFMS2380B
Vcc
Vout
GND
RD
OR
YL
PK
BL
RD
OR
YL
PK
BL
LED4
(UP/DOWN)
STEPPING MOTOR
DISPLAY
(UP/DOWN)
STEPPING MOTOR
R02T,10K
L1
ZBF503D
R03T,10K
R04T,10K
DC LOW
VOLTAGE GND
ZD02D
BZX55C11
R02D
20K
C06D
330
25V SD
4WAY
FAN
COMP
D/PUMP
1
2
IC02M
12V
SEL
5V
D07D
UG2D
C04D
470/35V/SD
COMP
C03D
681
JP2
JP1
CN-ACDC
12V
SEL
C02D
104
SMPS
6
7
Vref+
Vdd
MMOD
DC HIGH
VOLTAGE GND
C01D
15uF
450V/SG
13
XI 11
Vss 10
OSC1
FAN
4WAY
INDOOR FAN
INT
D/PUMP
10
10
D/PUMP
Rx
Tx
FAN
4WAY
12,26,31,45,46
54~56
SD01D
STO2D-200
JP6
JP5
JP4
JP3
NU
23 P11/TM1IO
21
53
27
OSC2
NRST/P27
D7/P87
IRQ0/P20
22 P10/TMOIO
35 P53/A16
IC01D
TNY266P
S 2,3,7,8
BP 1
33 P51/NRE
34 P52/NCS
D 5
EN 4
14 P00/SBO0
IRQ2/P22
28
29
IRQ3/P23
IRQ1/P21
24
25
30
TM3IO/P13
P54 36
17
18
19
3
4
TM2IO/P12
32 P50/NWE
15 P01/SBI0
Rx
Tx
16 P02/SBT0
60 P80/D0
59 P81/D1
2
1
58 P82/D2
57 P83/D3
52 P77/A15
PA7/AN7
PA5/AN5
PA6/AN6
SBT1/P05
SBI1/P04
20 BUZZER/P06
SBO1/P03
R01E
1K
49 P74/A12
48 P73/A11
47 P72/A10
44 P67/A7
43 P66/A6
50 P75/A13
51 P76/A14
DC HIGH
VOLTAGE GND
C05D
472M
R02E,20
41 P64/A4
42 P65/A5
12V
5V
COMP
IC02D
TLP181(V4 BL)
9
IC03M
7
6
61 Vref-
40 P63/A3
1
64
PA2/AN2
39 P62/A2
PA3/AN3
PA4/AN4
63
PA1/AN1
38 P61/A1
62
PA0/AN0
MICOM
MN101C30A QFP64
37 P60/AO
3
4
CN-ACDC
R03D
39
1/8W 2012
IC01M
BZ01E
PKM13EPY-4002
12V
12V
INDOOR FAN
INT
HVB OUT
INDOOR FAN
R01T,10K
1M
R01B
R03A
100
DC LOW
VOLTAGE GND
IC03D
TLP181(V4 BL)
SCL
5V
1
2
5V
RY-D/PUMP
RY-COMP
RY-4WAY
RY-FAN
D08D
LL4148
R05D
300K
1/4W
3216
DC HIGH
VOLTAGE GND
D05D
1N4007
OSC01B
3.6V
EEPROM
IC 1
R05G
1K
R06D
300K
1/4W 3216
BD01D
DF08M
C01G
103
5V
R11G
1K
5V
IC01A
SDA
Force
R04D
27k
1/8W 2012
NTC SCK-102
1K/1W
D/PUMP
5V
C02G
103
MODE/WC
R01P
10K
OR4H
OR3H
F3
R02F
10K
R02A,4.7K
FAN
4WAY
COMP
12V
5V
INT
C01Z
103
50V
C01A
10/
R01A
1K
C01F
103
OR2H
F2
R01F,1K
OR1H
F1
12.1K, 1%
R23H
12.1K, 1%
R22H
12.1K, 1%
R21H
6
5
C03J
100nF
275V/436D
R01J
120, 1/2W
C12K
103
NF01J
15mH/1A
IC01J
TLP762JF
C01L
680pF/50V
R07D
12K
NF02J
R02J
100,1/2W
TR01J
SM1L43
ZNR01J
TVR10561
FUSE
250V/T2A
RY-4WAY
G5N-1A(G5NB-1A)
RY-FAN
G5N-1A(G5NB-1A)
OR6H
CN-TAB1
2
1
T-BLOCK
1
2
3
1
2
CN-MOTOR
CN-FLOAT
RY-COMP
G4A-1A-E-LG
4
CN-DOOR
CN_INSTALL
receiver
5V
R01L
5.1K
INT
L02K
L03K
DC PART
R08D
56K
103
C01H
CN-TH1
CN-TH2
CN-REMO
5V
R01H
R02H
6.2K
12.1K
1%
1%
RY-D/PUMP
G5N-1A(G5NB-1A)
C01J
METAL FILM
100nM/275V/436D
NF02J
ZNR02J
TVR10561
R03J
680
1/2W
R02L,1K
Q01C
KTC3198-Y
2SC5343
5V
R06F,1K
R08F,1K
C04F
103
103
5V
C02H
C03H
R07F R05F
1K
1K
1K R06H
1K R05H
R03H
6.2K
1%
5V
1K R04H
12V
DAN212K
D03K
C03F
D02K
DAN212K
C10K
102
R04J
560
1/4W 3216
10K
R10G
12.1K
R06G
L01K
5V
10K
R16G
12.1K
R12G
100nH
R03F,10K
C02J
METAL FILM
47nM/275V/435D
INDOOR FAN
12V
R04F,1K
12V
C11K
104
40K
R09G
40K
R15G
Q04K
KRA104M
C09K
102
Q02K
KRC104M
4.2K
R09K
4 5
2
3
F 0 1
B
C
E
9 8 7
SW-LOW
5V
4
4 5
F 0 1
3
E
9 8 7
SW-HIGH
B
C
Q03K
KRC104M
20K
R08G
20K
R14G
5V
C02F,103
C08K
102
R08K
1K
KRA104M
Q01K
OR5H
80K
R07G
80K
R13G
T2
T1
LEV
1(L)
2(N)
AC220~240V
50/60Hz
CN-POWER
FAN MOTOR
OUTDOOR
CN-D/PUMP
SH-CAPACITOR
COMPRESSOR
4-WAY
Drain
Motor
INDOOR
FAN
MOTOR
PIPE-TH
ROOM-TH
PIPE-OUT_TH
Schematic Diagram
Service Manual 91
Schematic Diagram
2. Outdoor Unit
(1) AUUH488C/AUUH728C/AUUH1008C
IC01A
VCC
20
14
15
16
17
18
1
245
19
13
12
11
17
18
20
VCC
245
10
BUS_ADDR
CS_LEV12
A0
A3
A2
A1
A5
IC02A
B2
B1
B0
QE
B4
B3
B5
B6
B7
103
C05A
103
C06A
12V
ULN2803
IC03A
C01A 103
17
C02A
330uF/25V
16
10
18
9
1
14
15
11
12
13
5
6
12V
17
ULN2803
IC04A
C04A
330uF/25V
16
10
18
11
12
13
14
15
9
1
C03A 103
B3
B2
B1
B0
QE
B4
3
4
5
6
1
2
3
4
5
6
LEV1
CN_LEV1
CN_LEV2
LEV2
CN_LEV3
LEV3
CN_LEV4
LEV4
R01D
47K,1W,5%
1K * 3
R01J~R03J
A7
A5
A6
A3
A4
D01D
1N4007
BUS_ADDR
CS_LEV34
A0
A1
A2
CS_LEV12
R02D~R05D
47K,1/4W,5%
R06D
1K,1/4
5%
Q01A
KRA107M
IC01D
TLP421_BL
2012
R07D
10K
5V
R08D
1K
P61
P62
P63
P64
P65
60
P72
P73
P70
P71
P66
P67
VDD
61
62
59
R01A~R10A
68K
CN_CENTRAL
AR01A
4.7K,5%
2012
C01D
102K
51
52
53
54
55
56
57
58
63
64
1
P00
P01
P02
P74
P75
P76
P77
2
3
4
5
4
3
5V GND
C01R
0.01
TX
RX
R01R,R02R
10K
5%
C02R
0.001
R03R
1K
TMP87CM41F
(TOSHIBA)
35
A4
19
2
3
4
15
16
B6
B5
B7
10K * 3
(1/10W)
2012
R02U
4.7K
37
A6
A7
GND
A3
A2
A1
A0
CS_LEV34
5
14
6
13
1
2
ZONE SW1
ON
CN_PRESS
R01U
4.7K
2012
36
P37
P30
P35
P34
P33
P32
P31
P30
VSS
X
OUT
X
IN
16
34
33
32
31
30
29
28
27
26
24
25
23
22
21
20
19
IC01K
(KID65004AP)
RESET
P22
P21
TEST
P20
104 C01K
13
12
11
15
14
16
10
104 C02K
11
12
13
15
14
DC 12V
RY-FAN2H
RY-FAN2L
RY-FAN1L
RY-SV2
RY-FAN1H
RY-SV1
RY-4WAY2
RY-4WAY1
RY-COMP1
RY-COMP2
RY-COMP3
RY-COMP4
C01S
0.001
25V
C02S
0.001
25V
C03S
0.001
25V
C04S
0.001
25V
C05S
0.001
25V
C06S
0.001
25V
C08S
0.001
25V
C07S
0.001
25V
R01L
1K 2012
C01L
103
R05S
10K
R06S
10K
R07S
10K
R08S
10K
4
IC01S(TLP421)
IC02S(TLP421)
2
R09S
1K
1
IC03S(TLP421)
IC04S(TLP421)
2
R10S
1K
1
IC05S(TLP421)
2
R11S
1K
1
IC06S(TLP421)
3
4
IC07S(TLP421)
2
R12S
1K
1
1
2
3
M/S SW2
IC08S(TLP421)
M
S
1
2
3.6V
R13S
1.5K
ZD01S
68V
R14S
1.5K
ZD02S
68V
R15S
1.5K
ZD03S
68V
ZD04S
68V
R16S
1.5K
IC01Q
KIA7036P
10K
R04P
5V
1K
85uH
NF01M
12V
R03P
LED01T
C04M
460uF/35V
CST-8.00MTW
OSC01B
R02Q,4.7K
R03Q
100
5V
56K
R02P
1K
R01P
TEST S/W1
4.7K
2012
R02L
1
2
3
PIPE SW
G
C03M
104
IC01M
KIA78L05BP
O
I
7805
C02M
103
C02P
103
C01P
103
50V
C02Q
10
R01Q
1K
R01B
1M
DC 5V
R01S,1K
R02S,1K
R03S,1K
R04S,1K
C01Q
102
LONG
SHORT
5V
PIPE LENGTH
C01M
220uF/50V
(YELLOW)
C03Q
104
C01N
150uF/
100V
R01N
50.5K/1W
5V
D04S
1N4007
D02S
1N4007
D01S
1N4007
1
2
3
D03S
1N4007
M/S SW1
R17S
R18S
S
3,7,8
D05S
1N4007
R26S
30K, 1W
R19S
R20S
M
S
ST02D-170
(UF4005)
DC310V
C02N
102,100V
R25S
R21S
R22S
M S
M/S SW3
ZD01N
36V,1W
ZD02N
36V,1W
C08M
104
D
D02M
5
EN
4
TNY
IC03M
BP 266P TNY266P
1 2
S/Trans
R23S
R24S
6,7
4,5
C07M
0.01UF/400V
IC02M(TLP521)
470uF/35V
D01M
SB360
C05M (UF5402)
C06M
681
GND IN OUT 5V
CN_TEST
5V
R01M
39
R02M
150
ZD01M
11V
1
2
3
A4
12
11
5V
WP
Vcc
5
4
3
38
1
CN-COM
1
2
3
4
1N4007
D02N
1N4007
NTC01M
300D-9
C09M
33uF/
450V
A ROOM
B ROOM
C ROOM
()
R05N
11K/3W
R03N
11K/3W
Single ROOM
R02N
11K/3W
D01N
R04N
11K/3W
D03M
1N4007
R06N
1M,1/2W
AC_N
C03N
100nF
275V
AC_L
CN_NETWORK
NF
RY_FAN1L
RY_FAN2H
RY_4WAY1
RY_COMP1
RY_SV1
RY_COMP2
C04N
100nF
275V
RY_COMP3
RY_SV2
RY_4WAY2
RY_FAN2L
RY_FAN1H
FUSE
250V/T3.15A
ZNR01N
INR14D561K
INR14D471K
RY_COMP4
NF01N
22mH/3A
C01E
102
R01F
1K
C02F
102
SCL
SDA
39
IC02K
R04E
1K
R07E
10K
R05E
1K
C02E
102
C03E
102
R02F
10K
C01U
103
2012
2
3
EEPROM
M24C01-BN6
5V
10
4
3
4
3
R08E
10K
R06E
1K
R09E
10K
C01F
1UF
A2
A0
A1
5V
A5
IC01E
TLP421
1
2
4
3
C02L
103
R03L
2012 1K
12V
PRESS
HIGH
R02H,1K
R04J
A7
DC 5V
D01E
1N4148
D02E
1N4148
IC02E
TLP421
1
2
IC03E
TLP421
R01H
12.1K
1%
B
R05J
A6
GND
R01E
100K/3W
R02E
100K/3W
R03E
100K/3W
D03E
1N4148
R04L
4.7K
2012
1
2
3
M/S SW4
OR1H
XXX
5V
P17
5V
R06G
18K
1%
DC 5V
R05G
18K
1%
18
35204-0394
MOLEX
R04G
18K
1%
P15
P16
CN_3PHASE
R03G
6.2K
1%
5V
1K
40
P13
P14
16
17
5V
C01C
103
44
P11
P12
14
15
R02G
6.2K
1%
R01C
4.7K
2012
2012
R02C
45
P51
P50
P47
P46
12
13
DC 5V
R01G
12.1K
1%
R09G,1K
R10G,1K
R11G,1K
R13G,1K
R12G,1K
1
2
3
41
46
P52
P10
PRESS
LOW
R14G,1K
JIG SW
43
P53
11
CN_HON
CN_TH1
CN_TH2
CN_TH3
C09G~C14G
104
25V
42
47
P05
P06
P07
P43
P42
P41
P40
5V
PIPE1
OUTAIR
PIPE2
DISC1
DISC2
DISC3
C01G~C06G
1UF
50V
CN-POWER
CN_FAN1
FAN1
CN_FAN2
FAN2
CN_4,S
4WAY1
SV1
4WAY2
SV2
COMP1
CN_COMP
COMP3
COMP2
COMP4
LIVE
NEUTRAL
48
P54
P04
7
P45
P44
5V
49
50
P03
P60
VAREF
VASS
8
9
10
A
R06J
5V
5V
Schematic Diagram
Wiring Diagram
1. Cassette Type Indoor Unit
AC PCB ASSY
GN/YL
FUSE
CN-TH1
CN-TH2
CN-FLOAT
IN-PIPE.
THERMISTOR
ROOM
OUT-PIPE.
THERMISTOR THERMISTOR FLOAT S/W
CN-DISP
DISPLAY
PCB ASSY
CNMOTOR
RD
GN/YL
1(L) 2(N)
CN-HVB
HVB
CN-ACDC
CN-ACDC
A/CL UNIT
BL
BR
TO OUTDOOR UNIT
CN-UD1
DC PCB ASSY
S/W1
CENTRAL CONTROL
S/W2
STEP
MOTOR
CN-CC
CN-DOOR
WIRING DIAGRAM
CNDPUMP
OPTION
3854A20419D
Service Manual 93
Schematic Diagram
Outdoor Unit
1. AUUH488C
3. AUUH1008C
2. AUUH728C
Schematic Diagram
Components Locations
(1) Cassette Type -TE/TF/TD Chassis
58
58
Service Manual 95
Schematic Diagram
58
B
Schematic Diagram
(5) Convertible Type-VE Chassis
AC part
TOP VIEW
BOTTOM VIEW
TOP VIEW
BOTTOM VIEW
DC part
Service Manual 97
Schematic Diagram
2. Outdoor Unit
(1) AUUH488C/AUUH728C/AUUH1008C
1) Component side
R02N
C01N
R05D
R02D
CN_COMP
CN_4,S
CN_FAN1
RY_FAN1L
CN_FAN2
RY_FAN2H
J13
R03D
IC01E
R04D
IC01D
J18
RY_4WAY2
RY_SV2
RY_COMP40(1)
RY_COMP2(40)
RY_FAN1H
RY_SV1
RY_COMP60(1)
RY_4WAY1
RY_COMP2(60)
RY_FAN2L
CN_TEST
J12
TEST_SW1
CNLEV4
CNLEV3
J14
LED01T
R03S
R06N
R02Q
R01P
J20
J15
R08A
R09A
R10A
C04A
R02S
J07
OSC01B
J21
J16
R03A
R01D
NF01M
C04M
IC01Q
RX
NF01N
NTC01M
C01M
J05
R01L
PWB : 6870A90246A
5V
CN-CENTRAL
R07A
2004.05.11
R04S
J06
ASM : 6871A20583
ZONE SW1
J17
CNLEV2
R05A
R01S
R04A
J11
R06A
C03N
D03M
C07M
J02
R02H
J01
OR2H
C02A
R01A
EEPROM
R08D
C01F
C01G
R05E
CN_HON
C01Q
Q01A
0V
TX
TEST_SW2
J22
C02G
R10G
J08
C04G
R01F
CN_TH1
CNLEV1
R02A
J19
JIG_SW
C06G
C03G
R11G
C05M
J04
J03
R13G
C05G
R09G
IC02M
R01M
S/TRANS
ZNR01N
IC03M
ZD01N
CN_COM
ZD01S
D02E R02E
J09
R14G
D01M
ZD01M
IC02E
C04N
R04N
IC07S
D01D
R17S
AC_N
R24S
IC01M
J10
R12G
CN_TH2
R04E
D02N
ZD02S
R01E
R01N
ZD03S
CN_TH3
R06E
D02S
R20S
D01S
D01E
D02M
IC02S
R03E
D03E
IC03E
CN_PRESS
R18S
R06D
IC01S
ZD02N
R19S
IC03S
D03S
R22S
IC04S
R25S
C02N
ZD04S
R21S
IC05S
D04S
R23S
IC06S
R05N
D05S
R26S
IC08S
AC_L
D01N
R03N
C09M
Schematic Diagram
2) Solder side
2WS-S/M
3W/S SM
S21R
S61R
S50D
N20C
S70CI
N50R
M/S-SW1
N10FN
S50CI
S12R
N10RNZ
N20D
M90C
M10CTN
N10DZ
S20DZ
S40CI
S30D
S22R
S41R
S30CI
S91R
S20D
S02R
N20DZ
M80C
MOC_NC
S10DZ
S31R
S10CI
ESUF
M30CI
S20CI
S90R
N60R
N10R
M30D
N_CA
S40D
N30C
N10C
S32R
S51R
S01R
N40R
N40C
S30DZ
S60CI
S11R
N30R
N10D
S52R
S42R
N20R
L_CA
S40DZ
S80CI
S62R
SSERP_NC
M20D
S81R
D60R
E10R
M10D
M10DZ
M20R
M60C
M10R
E30D
M10FN
E30CI
M50C
E20R
D10CI
ESAHP3_NC
E20CI
E20D
REWOP_NC
D40R
D50R
E10CI
D20R
D10D
E10D
D30R
M70C
M20CI
S10D
SNART/S
S71R
D10R
E30R
40J
30J
G41R
G50C
G60R
G31C
G50R
G21C
L30R
G31R
G40C
G11C
G11R
C01C
M10CI
C10R
01J
90J
)1(04PMOC_YR
M20C
K20C
)06(2PMOC_YR
M10C
K20CI
G10C
F20C
F20R
46
2YAW4_YR
Q10CI
54
Q30R
B10R
A20C
R20R
2VS_YR
70J
P10C
12J
61J
A10CI
A10R
H1NAF_YR
A20R
02J
51J
S10R
A40R
A50R
A60C
A60R
A50C
S10C
11J
S30C
1NAF_NC
S50R
T10DEL
A30R
A40C
Q10C
P10R
A30CI
2VELNC
A10Q
Q20C
81J
RX
91J
1VS_YR
Q10R
R30R
P20C
R10R
B10CSO
R20C
0V
TX
03
5V
53
LARTNEC-NC
71J
A10C
S,4_NC
52
04
1VELNC
E10C
1YAW4_YR
L10C
C30Q
05
1WS ENOZ
E70R
K10CI
R10C
E20C
E40R
)04(2PMOC_YR
Q20R
J40R J30R
J50R J20R
J60R J10R
D10C
50J
E30C
E50R
E80R
55
20J
H20R
10J
H2RO
NOH_NC
E90R
K10C
L10R
06
H30R
T
M 51
IM P
C
8
O
P701
M
4M
F1
F10C
1HT_NC
F10R
E60R
PMOC_NC
U10C
U10R
G90R
T10C
80J
U20R
T10FN
MORPEE
G20C
G01R
C20R
22J
G01C
G90C
G20R
G10R
L20R
L40R
D80R
G30C
2HT_NC
G30R
)1(06PMOC_YR
M30C
L20C
G21R
G40R
2WS_TSET
M/S SW4
WS_GIJ
G60C
3HT_NC
M40C
D70R
G41C
L1NAF_YR
S20C
P30R
S20R
S60R
A70R
P40R
A30C
A80R
A90R
A01R
S40C
S50C
S30R
1WS_TSET
H2NAF_YR
S70R
A20CI
A40CI
A10RA
P20R
31J
S80R
S60C
2NAF_NC
3VELNC
4VELNC
41J
S40R
S70C
60J
TSET_NC
21J
L2NAF_YR
S80C
Service Manual 99
Piping Diagrams
Piping Diagrams
1. AUUH488C
"Synchro" Duo - AUUH488C
INDOOR UNIT
OUTDOOR UNIT
Reversing
Valve
Heat
Exchanger
Heat
Exchanger
Thermistor
Low
pressure
s/w
option
Fan
Check
Valve
Gas Piping
B
Thermistor
High
pressure
s/w
Check
Valve
Thermistor
Accumulator
Liquid Piping
A
Fan
Branch kit
(Accessory)
Thermistor
INDOOR UNIT
Constant
Compressor 1
Heat
Exchanger
Constant
Compressor 2
L.E.V.
Service Valve
Gas( 19.05mm)
Service Valve
Liquid( 9.52mm)
Fan
Gas Piping
B
Branch kit
(Accessory)
Thermistor
Liquid Piping
A
Indoor Unit
(Btu/h)
A
(mm)
B
(mm)
Refrigerant Flow
18k, 24k
6.35
12.7
Cooling
Heating
30k
6.35
15.88
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Heat
Exchanger
Heat
Exchanger
Thermistor
Fan
Thermistor
Liquid Piping
A
Check
Valve
Check
Valve
Thermistor
Branch kit
(Accessory)
INDOOR UNIT
High
pressure
s/w
Low
pressure
s/w
option
Gas Piping
B
Accumulator
Fan
Heat
Exchanger
Thermistor
Constant
Compressor 1
Fan
Gas
Piping
B
Thermistor
Liquid Piping
A
INDOOR UNIT
Heat
Exchanger
Constant
Compressor 2
L.E.V.
Service Valve
Gas( 19.05mm)
Service Valve
Liquid( 9.52mm)
Branch kit
(Accessory)
Fan
Gas Piping
B
Thermistor
Liquid Piping
A
Indoor Unit
(Btu/h)
A
(mm)
B
(mm)
Refrigerant Flow
18k
6.35
12.7
Cooling
Heating
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Piping Diagrams
Heat
Exchanger
Reversing
Valve
Fan
Thermist
or
Heat
Exchanger
Gas
Piping
B
Thermistor
Liquid
Piping
A
INDOOR UNIT
High
pressure
s/w
Low
pressure
s/w
option
Heat
Exchanger
Check
Valve
Check
Valve
Thermistor
Fan
Thermist
or
Gas
Piping
B
Branch kit
(Accessory)
Accumulator
Fan
Thermistor
Liquid
Piping
A
INDOOR UNIT
Heat
Exchanger
Constant
Compressor 1
Constant
Compressor 2
L.E.V.
Service Valve
Gas( 19.05mm)
Fan
Thermist
or
Gas
Piping
B
Liquid
Piping
A
INDOOR UNIT
Heat
Exchanger
Fan
Thermist
or
Gas Piping
B
Service Valve
Liquid( 9.52mm)
Branch kit
(Accessory)
Indoor Unit
(Btu/h)
A
(mm)
B
(mm)
12k
6.35
9.52
Refrigerant Flow
Cooling
Heating
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Liquid Piping
A
Piping Diagrams
2. AUUH728C
"Synchro" Duo - AUUH728C
INDOOR UNIT
OUTDOOR UNIT
Reversing
Valve
Heat
Exchanger
Heat
Exchanger
Thermistor
Low
Pressure
S/W
Fan
Check
Valve
Gas Piping
B
Thermistor
High
Pressure
S/W
Check
Valve
Check
Valve
Thermistor
Accumulator
Liquid Piping
A
Fan
Branch kit
(Accessory)
Thermistor
INDOOR UNIT
Constant
Constant
Compressor 1 Compressor 2
Heat
Exchanger
Constant
Compressor 3
L.E.V.
Service Valve
Gas( 25.4mm)
Service Valve
Liquid( 9.52mm)
Fan
Gas Piping
B
Branch kit
(Accessory)
Thermistor
Liquid Piping
A
Indoor Unit
(Btu/h)
A
(mm)
B
(mm)
30k, 36k
6.35
15.88
Refrigerant Flow
Cooling
Heating
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Heat
Exchanger
Heat
Exchanger
Thermistor
Fan
Gas Piping
B
Low
Pressure
S/W
Liquid Piping
A
Thermistor
Thermistor
Check
Valve
Branch kit
(Accessory)
INDOOR UNIT
High
Pressure
S/W
Check
Valve
Check
Valve
Accumulator
Fan
Heat
Exchanger
Thermistor
Constant
Constant
Compressor 1 Compressor 2
Fan
Gas
Piping
B
Thermistor
Liquid Piping
A
INDOOR UNIT
Heat
Exchanger
Constant
Compressor 3
L.E.V.
Service Valve
Gas( 25.4mm)
Service Valve
Liquid( 9.52mm)
Branch kit
(Accessory)
Fan
Gas Piping
B
Thermistor
Liquid Piping
A
Indoor Unit
(Btu/h)
A
(mm)
B
(mm)
18k
6.35
12.7
24 k, 30k, 36k
6.35
15.88
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Refrigerant Flow
Cooling
Heating
Piping Diagrams
Heat
Exchanger
Reversing
Valve
Fan
Thermist
or
Heat
Exchanger
Gas
Piping
B
Thermistor
Liquid
Piping
A
INDOOR UNIT
High
Pressure
S/W
Low
Pressure
S/W
Heat
Exchanger
Check
Valve
Check
Valve
Check
Valve
Thermistor
Fan
Thermist
or
Gas
Piping
B
Branch kit
(Accessory)
Accumulator
Fan
Thermistor
Liquid
Piping
A
INDOOR UNIT
Heat
Exchanger
Constant
Constant
Compressor 1 Compressor 2
Constant
Compressor 3
L.E.V.
Service Valve
Gas( 25.4mm)
Fan
Thermist
or
Gas
Piping
B
Liquid
Piping
A
INDOOR UNIT
Service Valve
Liquid( 9.52mm)
Branch kit
(Accessory)
Heat
Exchanger
Fan
Thermist
or
Indoor Unit
(Btu/h)
A
(mm)
B
(mm)
18k
6.35
12.7
Refrigerant Flow
Cooling
Heating
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Gas Piping
B
Liquid Piping
A
3. AUUH1008C
"Synchro" Duo - AUUH1008C
INDOOR UNIT
OUTDOOR UNIT
Reversing
Valve
Heat
Exchanger
Heat
Exchanger
Thermistor
Fan
Check
Valve
Gas Piping
B
Thermistor
High
Pressure
S/W
Low
Pressure
S/W
Check
Valve
Thermistor
Accumulator
Liquid Piping
A
Fan
Branch kit
(Accessory)
Thermistor
INDOOR UNIT
Constant
Compressor 1
Heat
Exchanger
Constant
Compressor 2
L.E.V.
Service Valve
Gas( 25.4mm)
Service Valve
Liquid( 12.7mm)
Fan
Gas Piping
B
Thermistor
Liquid Piping
A
Branch kit
(Accessory)
Indoor Unit
(Btu/h)
A
(mm)
B
(mm)
Refrigerant Flow
36k
6.35
15.88
Cooling
Heating
48 k, 60k
9.52
19.05
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Piping Diagrams
OUTDOOR UNIT
INDOOR UNIT
Reversing
Valve
Heat
Exchanger
Heat
Exchanger
Thermistor
Fan
High
Pressure
S/W
Low
Pressure
S/W
Gas Piping
B
Thermistor
Check
Valve
Liquid Piping
A
Branch kit
(Accessory)
INDOOR UNIT
Check
Valve
Thermistor
Accumulator
Fan
Heat
Exchanger
Thermistor
Constant
Compressor 1
Fan
Gas
Piping
B
Thermistor
Liquid Piping
A
INDOOR UNIT
Heat
Exchanger
Constant
Compressor 2
L.E.V.
Service Valve
Gas( 25.4mm)
Service Valve
Liquid( 12.7mm)
Branch kit
(Accessory)
Fan
Indoor Unit
(Btu/h)
A
(mm)
B
(mm)
Refrigerant Flow
24 k, 30k, 36k
6.35
15.88
Cooling
Heating
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Gas Piping
B
Thermistor
Liquid Piping
A
Heat
Exchanger
Reversing
Valve
Fan
Thermist
or
Heat
Exchanger
Gas
Piping
B
Thermistor
Liquid
Piping
A
INDOOR UNIT
High
Pressure
S/W
Low
Pressure
S/W
Heat
Exchanger
Check
Valve
Check
Valve
Thermistor
Fan
Thermist
or
Gas
Piping
B
Branch kit
(Accessory)
Accumulator
Fan
Thermistor
Liquid
Piping
A
INDOOR UNIT
Heat
Exchanger
Constant
Compressor 1
Constant
Compressor 2
L.E.V.
Service Valve
Gas( 25.4mm)
Fan
Thermist
or
Gas
Piping
B
Liquid
Piping
A
INDOOR UNIT
Heat
Exchanger
Service Valve
Liquid( 12.7mm)
Branch kit
(Accessory)
Indoor Unit
(Btu/h)
24 k
Fan
Thermist
or
Gas Piping
B
Liquid Piping
A
A
(mm)
B
(mm)
6.35
15.88
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Refrigerant Flow
Cooling
Heating
Troubleshooting Guide
Troubleshooting Guide
Cycle Troubleshooting Guide
Trouble analysis
1. Check temperature difference between intake and discharge air, and operating current.
Temp. difference
Current
: approx. 0C
: less than 80% of
rated current
Temp. difference
Current
: approx. 8C
: less than 80% of
rated current
Refrigerant leakage
Clog of refrigeration cycle
Defective compressor
Temp. difference
Current
: less than 8C
: near the rated
current
Temp. difference
: over 8C
Temp. Difference
Operating Current
Excessive amount of refrigerant
Normal
Notice:
Temperature difference between intake and discharge air depends on room air humidity. When the room air
humidity is relatively higher, temperature difference is smaller. When the room air humidity is relatively lower
temperature difference is larger.
2. Check temperature and pressure of refrigeration cycle.
Suction pressure
(Compared with
the normal value)
Temperature
(Compared with
the normal value)
Cause of Trouble
Description
High
Defective compressor
Current is low.
Normal
Excessive amount of
refrigerant
Insufficient amount of
refrigerant(Leakage)
Clogging
Current is low.
Higher
Lower
Higher
Notice:
1. The suction pressure is usually 4.5~6.0 kg/cm G at normal condition.
2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with
putty.
2
Troubleshooting Guide
Turn off the main power and wait until LED on outdoor PCB is off
* The product's operation starts at three minutes after main power turning on
Troubleshooting Guide
Trouble 2
While the compressor has been stopped, the compressor does not operate
owing to the delaying function for 3 minutes after stopped.
Troubleshooting Guide
Trouble 3
When the sensor circuit for indoor temperature and connector are in bad
connection or are not engaged, Compressor/Outdoor Fan is stopped.
Check the indoor temperature sensor is disconnected or not(About 10k / at 25C).
COMP ON
COMP OFF
Below DC 1V
(app)
About DC12V
Troubleshooting Guide
Trouble 4
In heating Mode, the indoor fan operates in case the pipe temperature
is higher than 28C.
4-Way Relay
Comp ON
Comp OFF
About DC
12V
Check point
4-Way ON
4-Way OFF
Troubleshooting Guide
Trouble 5
SSR Check
Troubleshooting Guide
Trouble 6
Troubleshooting Guide
Self-diagnosis Function
Error Indicator
The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble.
Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.
If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed.
After error occurrence, if error is released, error LED is also released simultaneously.
To operate again on the occurrence of error code, be sure to turn off the power and then turn on.
Having or not of error code is different from Model.
Indoor Error
Error code
Description
MPS
Variable
MPS
Inverter
LED 1
(Red)
LED 2
(Green)
Indoor
Status
00
No Error
ON
01
1 time
OFF
02
2 times
OFF
03
3 times
OFF
04
4 times
OFF
05
5 times
OFF
06
6 times
OFF
Outdoor Error
Error Code
Description
21
22
23
24
25
26
27
28
32
33
40
41
44
45
46
47
51
53
54
60
61
62
63
65
DC Peak(IPM Fault)
CT2(Max CT)
DC Link Low Volt
High/Low Pressure/Heatsink Switch
Low Voltage / Over Voltage
DC COMP Position Error
PSC Fault Error
DC Link High Volt
D-Pipe High(INV)
D-Pipe High(Normal)
CT Sensor(open/short)
INV. D-Pipe Thermistor Error(Open/Short)
Outdoor Air Thermistor Error(Open/Short)
Cond Pipe Thermistor Error(Open/Short)
Suction Pipe Thermistor Error(Open/Short)
Const. D-Pipe Thermistor Error(Open/Short)
Capcity Error(High/Low)
Signal Error(Indoor_Outdoor)
Phase Error
EEPROM Check Sum Error
Cond Pipe High
Heatsink High
Cond Pipe Low
Heatsink Thermistor Error(Open/Short)
MPS
Variable
MPS
Inverter
LED 1
(Red)
2 times
2 times
2 times
2 times
2 times
2 times
2 times
2 times
3 times
3 times
4 times
4 times
4 times
4 times
4 times
4 times
5 times
5 times
5 times
6 times
6 times
6 times
6 times
6 times
LED 2
(Green)
1 time
2 times
3 times
4 times
5 times
6 times
7 times
8 times
2 times
3 times
1 times
4 times
5 times
6 times
7 times
1 times
3 times
4 times
1 times
2 times
3 times
5 times
Indoor
Status
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Troubleshooting Guide
Title
01
Open / Short
Soldered poorly
Internal circuit error
02
Open / Short
Soldered poorly
Internal circuit error
Open / Short
Soldered poorly
Internal circuit error
06
Cause of error
10k
2.5Vdc
Check Point
1. Unplug the sensor on Indoor unit PCB.
2. Estimate the resistance of each sensor.
3. If the resistance of the sensor is 10K/ 5K at 25C, then sensor is normal.
4. If the resistance of the sensor is 0 K or , then sensor is abnormal. Change the sensor.
5. Plug the sensor on Indoor unit PCB and Power ON.
6. Estimate the voltage of each sensor.
7. If the voltage of the sensor is 2.5Vdc at 25C, then sensor is normal.
8. If the resistance of the sensor is 0 or 5Vdc, then sensor is abnormal. Repair or Change the PCB.
Troubleshooting Guide
Troubleshooting CH03
Display
code
Title
03
Communication
Wired R/C
Cause of error
Open / Short
Wrong connection
Wired R/C
12V
Indoor Unit
GND
12V
GND
12Vdc
12Vdc
Check Point
1. Check the wire connection. (Open / Short) Repair the connection
2. Check the soldering state of connector. (Soldered poorly) Repair or Change the PCB.
3. Check the volt. Of main PCB power source. (DC 12V, DC 5V) Repair or Change the main PCB.
4. Check the installation of wired remote controller. (Noise interference) Adjust the state of installation
Troubleshooting Guide
Troubleshooting CH04
Display
code
Title
04
Drain pump
/ Float switch
Cause of error
CN Float
Check Point
1. Check the wire connection. (Open, Soldered poorly) Repair the connection or change the PCB.
2. Check the resistance of float switch (Abnormal : Open, Normal : short) Check the float switch.
3. Check the level of water
4. Check the volt. Of Drain pump power supply. (AC 230V) Repair or Change the main PCB.
Troubleshooting Guide
05
/
53
Title
Communication
(Indoor Outdoor)
Cause of error
Communication poorly
Check Point
1. Check the input power AC230V. (Outdoor, Indoor unit)
2. Check the communication wires are correctly connected.
Adjust the connection of wire
Confirm the wire of Live, Neutral
3. Check the resistance between communication line and GND. (Normal : Over 2M)
4. Check the connector for communication is correctly
connected.
5. Check the connection of GND1, GND2, and main GND.
6. If one indoor unit is operated normally, outdoor PCB is no problem.
Check the another indoor unit.
* CH05 is displayed at indoor unit, CH53 is displayed at outdoor unit.
Troubleshooting Guide
Troubleshooting CH21
Display
code
Title
21
Cause of error
DC Peak
Comp
U
Terminal
U-V
V-W
W-U
Comp
Resistance() at 20C
Copper
pipe
Inverter Constant
comp.
comp.
0.64
0.64
0.64
0.8
0.8
0.8
Resistance() at 20C
Terminal
U-GND
V-GND
W-GND
Inverter Constant
comp.
comp.
2M
2M
2M
2M
2M
2M
Check Point
1. Check the wire connection. (U,V,W)
2. Check the load condition. (Refrigerant, Pipe length, ) Adjust the load condition
3. Check the electricity leakage of the compressor. Normal : Over 2M.
4. Check the resistance of compressor. Normal : 0.65(INV), 0.8(Cons.) No difference at each terminal.
5. Check the insulation from water at IPM part. Check the trace of water.
6. Check the IPM circuit.
Troubleshooting Guide
Troubleshooting CH22
Display
code
Title
Cause of error
21
Max. C/T
22
C/T
Internal circuit
Malfunction of compressor
Blocking of pipe
Low voltage input
Refrigerant, pipe length, blocked,
Check Point
1. Check the power source.
2. Check the fan operation is right.
3. Check the current.
4. Check the install condition.
5. Check the internal circuit. (C/T, Diode, Resistor)
Troubleshooting Guide
Title
24
25
Input voltage
Cause of error
Check Point
CH 24
CH 25
Troubleshooting Guide
Title
26
DC Compressor
Position
27
PSC Fault
Cause of error
Compressor
position detect error
E
C
B
B
E
Check Point
CH 26
CH 27
Troubleshooting Guide
Title
32
D-pipe (Inverter)
temp. high
(105C )
33
D-pipe (Constant)
temp. high
(105C )
P OFF
Cause of error
Discharge sensor
(Inverter) temp. high
Discharge sensor
(Cons.) temp. high
115C
N/Hz down
100C
N/Hz down
95C
COMP OFF
LEV OPEN
LEV OPEN
NORMAL
RMAL
AUUW6060
AUUH488C/AUUH728C/AUUH1008C
Check Point
CH 32
CH 33
Troubleshooting Guide
Title
41
Open / Short
Soldered poorly
Internal circuit error
44
Air sensor
Open / Short
Soldered poorly
Internal circuit error
45
Open / Short
Soldered poorly
Internal circuit error
46
Open / Short
Soldered poorly
Internal circuit error
47
Open / Short
Soldered poorly
Internal circuit error
65
Open / Short
Soldered poorly
Internal circuit error
Cause of error
Check Point
1. Estimate the resistance of each sensor.(Unplugged)
2. Estimate the voltage of each sensor.(Plugged)
3. If the resistance of the sensor is 0 k or , then sensor is abnormal.
Troubleshooting Guide
Title
51
Capacity Error
EEPROM
Check sum
60
Cause of error
Over Capacity
Combination
Undder Capacity
Combination
Model
Min. Capacity
Gross Capacity
Max.Capacity
AUUH488C
25k
48k
58k
AUUH728C
37k
72k
85k
AUUH1008C
50k
100k
120k
Check Point
CH 51
CH 60
Troubleshooting Guide
Troubleshooting CH54
Display
code
Title
54
Phase error
Cause of error
Phase change
Phase_A
5.3 msec
Phase_B
Phase_C
1
0
1
1
0
0
1
1
0
0
1
0
0
1
1
0
0
1
Check Point
1. Check the Main power.
2. Check the connecting state of connector CN_3PHASE on the outdoor pcb ass'y.
Troubleshooting Guide
Title
Cause of error
61
Condenser
pipe sensor
temp. high
62
COMP Frequency
Normal
(Hz)
Normal
OFF
Normal
Check Point
CH 61
CH 62
(3-way) Valve
(3-way) Valve
3-way Valve (Liguid Side)
Valve cap
Valve cap
Open position
Closed position
Open position
Closed position
Pin
Pin
To piping
connection
Service Service
port cap port
To outdoor unit
1.
To piping
connection
Service Service
port cap port
To outdoor unit
Works
Shaft position
Service port
Shaft position
Service port
Shipping
Closed
(with valve cap)
Closed
(with cap)
Closed
(with valve cap)
Closed
(with cap)
Closed
(clockwise)
Open
(push-pin or with
vacuum pump)
Closed
(with cap)
Air purging
(Installation)
Open
Open
(counter-clockwise) (push-pin or with
vacuum pump)
Operation
Open
(with valve cap)
Closed
(with cap)
Open
(with valve cap)
Pumping down
(Transfering)
Closed
(clockwise)
Closed
(with cap)
Open
(counter-clockwise)
Open
(connected
manifold gauge)
Evacuation
(Servicing)
Open
Open
(connected
manifold gauge)
Open
3.
Open
(connected
manifold gauge)
Gas charging
(Servicing)
Open
Closed
(with cap)
Open
4.
Pressure check
(Servicing)
Open
Open
(connected
manifold gauge)
Open
5.
Open
(connected
manifold gauge)
Gas releasing
(Servicing)
Open
Open
(connected
manifold gauge)
Open
6.
Open
(connected
manifold gauge)
2.
Open
(with charging
cylinder)
(3-way) Valve
Liquid side
Indoor unit
3-Way
valve
Open
Outdoor unit
Gas side
Closed
3-Way
valve
Lo
CLOSE
CLOSE
Procedure
For pumping down,firstly short the Low Pressure
s/w at the outside and then operate below procedure.(except AUUH488B)
1. Confirm that both the gas side and liquid side
valves are set to the open position.
- Remove the valve stem caps and confirm that
the valve stems are in the raised position.
- Be sure to use a hexagonal wrench to operate
the valve stems.
2. Operate the unit for 10 to 15 minutes.
3. Stop operation and wait for 3 minutes, then connect the manifold gauge to the service port of
the gas side valve.
- Connect the hose of the gauge with the push
pin to the service port.
(3-way) Valve
(2) Evacuation
(All amount of refrigerant leaked)
Liquid side
Indoor unit
Outdoor unit
2-Way
valve
Open
Gas side
3-Way
valve
Open
Vacuum pump
Lo
OPEN
CLOSE
Procedure
1. Confirm that both the liguid side valve and gas
side valve are set to the opened position.
2. Connect the vaccum pump to the center hose of
the manifold gauge.
3. Connect the service port of the gas side valve to
the low side of the gauge.
4. Evacuation for approximately one hour.
- Confirm that the gauge needle has moved
toward-76 cmHg (vacuum of 4 mmHg or less).
5. Close the Low handle of the gauge turn off the
vacuum pump, and confirm that the gauge needle does not move(approximately 5 minutes
after turning off the vacuum pump).
(3-way) Valve
Liquid side
Indoor unit
2-Way
valve
Open
Outdoor unit
Gas side
Open
3-Way
valve
Check valve
Charging
cylinder
Lo
(1)
OPEN
CLOSE
Procedure
1. Connect the gauge to the charging cylinder.
- Connect the charge hose which you disconnected from the vacuum pump to the valve at the
bottom of the cylinder.
- If you are using a gas cylinder, also use a scale
and reverse the cylinder so that the system can
be charged with liquid.
2. Purge the air from the charge hose.
- Open the valve at the bottom of the cylinder and
press the check valve on the charge set to purge
the air. (Be careful of the liquid refrigerant). The
procedure is the same if using a gas cylinder.
3. Open the low handle on the gauge and charge
the system with liquid refrigerant.
- If the system can not be charged with the specified amount of refrigerant, it can be charged
with a little at a time (approximately 150g each
time) while operating the air conditioner in the
cooling cycle; however, one time is not sufficient, wait approximately 1 minute and then
repeat the procedure(pumping down-pin).
Function
Soft-Dry Operation
The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is impossible because of
already being set to the best speed for Dry Operation by microcontroller control.
INDOOR FAN
Selected
Speed
More than
More than
3 minutes
3 minutes
Low
Selected
Speed
Low
Selected
Speed
Vane 2
Vane 3
Vane 4
Function
32C
A
29C
21C
17C
Setting Temperature
(Thermo ON)
Minimum
3min
1min
COMP
OFF
OFF
ON
ON
Outdoor fan
Setting
Lo
fan
Off Low Low
spped
Indoor fan
4way valve
1min
Setting
fan
spped
Low
Low
Off
ON
ON
Off
Low
Setting
fan
spped
ON
Hot-start Control
The indoor fan does no rotate until the evaporator piping temperature will be reached to 21C.
The operation diagram is as following.
Pipe
temperature
32 C
29 C
23 C
21 C
17 C
Indoor fan
speed
COMP
LO
LOW
OFF
LOW
SELECTED
FAN
LOW
LOLOW
ON
Function
INDOOR FAN
COMPRESSOR
More than
More than
3 minutes
3 minutes
Selecting
fan speed
Low
Selecting
fan speed
Low
Selecting
fan speed
ON
OFF
ON
OFF
ON
Function
Indoor unit
40C
Heat-Exchanger
temperature
33C
A
30C
27C
20C
Setting Temperature
(Thermo ON)
Minimum
3min
1min
COMP
Outdoor fan
Indoor fan
4way valve
OFF
OFF
ON
ON
Setting
Lo
fan
Off Low Low
spped
1min
Low
Setting
fan
spped
Low
Off
ON
ON
Off
Low
Setting
fan
spped
ON
Compressor-off interval : - A While the indoor Heat-Exchanger temperature is higher than 40C, fan operates
at low speed, when it becomes lower than 40C fan stops.
- B For eluminating latent heat-loss, fan operates at low speed for 10 seconds periodically.
Function
Hot-Start Control
The indoor fan does not rotate until the indoor unit Hex-Exchanger temperature reaches 27C.
The operation diagram is as following.
Indoor unit
Heat-Exchanger
temperature
33C
27C
20C
1min
Compressor
Outdoor fan
Indoor fan
1min
ON
ON
Off
4way Valve
Low
Setting fan
spped
ON
Off
Low
Setting fan
spped
Function
INDOOR FAN
COMPRESSOR
More than
More than
3 minutes
3 minutes
Selecting
fan speed
Low
Selecting
fan speed
Low
Selecting
fan speed
ON
OFF
ON
OFF
ON
Function
32C
A
29C
21C
17C
Setting Temperature
(Thermo ON)
Minimum
3min
1min
COMP
Indoor fan
OFF
OFF
ON
ON
Outdoor fan
Setting
Lo
fan
Off Low Low
spped
4way valve
1min
Low
Setting
fan
spped
Low
Off
ON
ON
Off
Low
Setting
fan
spped
ON
Compressor-off interval : - A While the indoor Heat-Exchanger temperature is higher than 35C, fan operates
at low speed, when it becomes lower than 35C fan stops.
- B For eluminating latent heat-loss, fan operates at low speed for 10 seconds
periodically.
Function
Hot-Start Control
The indoor fan does not rotate until the indoor unit Hex-Exchanger temperature reaches 21C.
The operation diagram is as following.
Indoor unit
Heat-Exchanger
temperature
32C
21C
17C
1min
Compressor
Outdoor fan
Indoor fan
4way Valve
ON
ON
Off
Low
Setting fan
spped
Low
Setting fan
spped
ON
Outdoor Units
Heating mode
Stop state
Compressor
Step Control
Step Control
Stop
Fan
Phase control
Phase control
EEV
Target Suction super heat and Target Suction super heat and
Discharge Temp. Control
Discharge Temp. Control
4 way valve
Off
On
48k
72k
100k
COMP
B COMP
A COMP
a
b+b
MODE
STEP1
B COMP
STEP2
A COMP
STEP3
B+A COMP
Cooling
Heating
Cooling
Heating
Cooling
Heating
Outdoor Units
(2) Operation field for Temp.
Cooling
Outdoor Temp.
28C
27C
Standard
Step
25C
24C
Hysterisis
1 Step Down
21C 22C 23C 24C Indoor Temp.
Heating
Outdoor Temp.
27C
26C
1 Step Down
22C
21C
Hysterisis
15C
Standard
Step
15C
27C
30C
Indoor Temp.
Outdoor Units
2) Starting Control (LEV target open_degree arrival process after starting Comp)
(1) LEV is arrived the previous decided open_degree within 30 seconds after starting COMP.
(2) The open-degree is increased to target_degree in proportion to Comp operation time.
The starting controls time is within 120 seconds after COMP operation
3) Normal Control
: The condensor's degree of superheat control + Compressor Discharge-Temp. Control
(1) Cooling mode
In cooling mode, normal control regulates EEV pulse that continues to fixed value for Superheat Temp. of
the operating indoor unit.
Control subject : The pipe Temp. of outdoor_unit
T_Target
Outdoor Units
(4) Compressor Discharge-Temp. Control
After 1 min. of normal control, if it is satisfied with fomula below, it starts to control of Comp. Discharge
Temp.
Cooling mode : The present degree of superheat 3 (Option)
Heating mode : The target degree of superheat < 0 , The present degree of superheat 0 (Option)
The present degree of superheat 0, The present degree of superheat 5 (Option)
The target degree of superheat is decided for indoor_unit and operation mode.
The target Temp. of discharge pipe is decided for indoor_unit, outdoor_unit and Comp operation Step, the
difference indoor and outdoor.
FULL SPEED
OFF
Phase control
FULL SPEED
SPEED SLOPE
(OPTION)
40
%
OFF
SET POINT
: Outdoor Temp.
or Outdoor pipe Temp.
(OPTION)
(2) HEATING
Air
circulation
OFF
FULL SPEED
FULL SPEED
OFF
Outdoor Fan
OFF Temp.
or Outdoor pipe
Temp. (OPTION)
Outdoor Fan
OFF Temp.
or Outdoor pipe
Temp. (OPTION)
Outdoor Units
Outdoor Units
2. Special control
2.1 Defrost control
: In case the temperature of the outdoor unit heat exchanger falls continuously this function will prevent
heat exchanger from freezing.
Outdoor Units
60min
30sec
Outdoor Units
3. Protection control
3.1 Discharge Temperature control
Discharge pipe Temperature
COMP OFF
115C
LEV OPEN (50PULSE/MIN )
100C
LEV OPEN (30PULSE/MIN )
95C
COMP ON
Outdoor Units
Open Data
Short Data
Error Mode
Outdoor Temp.
-48C
93C
44
-48C
93C
45
-48C
93C
48
-13C
150C
47
266090
249951
263230-3
263230-2
263230-1
268714
159830
354211
352118
35211A
158591
266012
330870
130411
W0CZZ
346810
359012
130911-1
267110-2
130911-2
267110-1
PART No.
ATNH126ELFC
ATNH186ELFC
SVC
CODE
3041A10013A
3041A10013A
3091A10023C
3091A10023C
3091A10023D
3091A10023D
5859A20001R
5859A20001R
5983A10002A
5983A10002A
4994A10014A
4994A10014A
4995A14001P
4995A14001Z
6323AQ3226F
6323AQ3226F
6323AQ3226T
6323AQ3226T
6323A10002A
6323A10002A
6601A20001M
6601A20001M
6609A20005C
6609A20005C
6711A20096H
6711A20096H
6711A20076J
6711A20076J
6871A10370C
6871A10370D
3087A10002A
3087A10002A
4681AC2026E
4681AC2026C
5211A20243M
5211A20243N
5211A20241S
5211A20241R
5421A10006A
5421A10006A
359012 FAN,TURBO
5900A10004A
5900A10004A
3H00660N
3H00660N
DESCRIPTION
W0CZZ CAPACITOR,DRAWING
TF chassis
349490
266090
263230-3
263230-2
263230-1
249951
268714
354211-2
354211-1
159830
352118-2
552111
352118-1
158591
330870
266012
130411
W0CZZ
346810
359012
130911-2
130911-1
267110-2
267110-1
PART No.
ATNH246FLFC
ATNH306FLFC
SVC
CODE
3041A10030B
3041A10030B
3091A10051C
3091A10051C
3091A10051D
3091A10051D
5859A20001S
5859A20001S
5983A10002A
5983A10002A
4995A10131K
4995A10131J
6323AQ3226Y
6323AQ3226Y
6323AQ3226E
6323AQ3226E
6323A10002A
6323A10002A
6601A20001N
6601A20001N
6609A20005E
6609A20005E
6711A20096H
6711A20096H
6711A20076J
6711A20076J
6871A10370E
6871A10370F
3087A10010B
3087A10010B
4681A20051Z
4681A20051W
5211A20251Q
5211A20251K
5211A20251K
5211A20251U
5421A10016G
5421A10016G
5421A10016H
5421A10016H
5901A10036A
5901A10036A
5211A21137C
5211A21137C
3H00660M
3H00660M
DESCRIPTION
W0CZZ CAPACITOR,DRAWING
TD chassis
263230-3
263230-2
263230-1
349490
249951
266090
268714
159830
354211-2
130411
354211-1
55211-2
552111
352118-1
330870
158591
266012
130411
W0CZZ
346810
359012
130911-2
130911-3
267110-2
130911-4
130911-1
267110-1
352150-2
DESCRIPTION
PART No.
ATNH366DLFC
ATNH486DLFC
ATNH606DLFC
SVC
CODE
130411
130911-1
130911-2
130911-3
130911-4
158591
159830
249951
263230-1
263230-2
BASE ASSEMBLY,WELD(INDOOR)
CABINET ASSEMBLY,INDOOR
CABINET ASSEMBLY,INDOOR
CABINET ASSEMBLY,INDOOR
CABINET ASSEMBLY,INDOOR
PUMP ASSEMBLY,WATER
AIR CLEANER ASSEMBLY
CONTROL BOX ASSEMBLY,INDOOR
THERMISTOR ASSEMBLY
THERMISTOR ASSEMBLY
3041A10016A
3091A20034A
3091A20034B
3091A20035A
3091A20035B
5859A20001T
5983A10003D
4995A22010L
6323A30002A
6323AQ3226T
3041A10016A
3091A20034A
3091A20034B
3091A20035A
3091A20035B
5859A20001T
5983A10003D
4995A22010M
6323A30002A
6323AQ3226T
3041A10016A
3091A20034A
3091A20034B
3091A20035A
3091A20035B
5859A20001T
5983A10003D
4995A22010P
6323A30002A
6323AQ3226T
R
R
R
R
R
R
R
R
R
R
263230-3
266012
266090
267110-1
267110-2
268714
330870
346810
349490
352118-1
352118-2
352150
354211-1
354211-2
359012
552111
W0CZZ
THERMISTOR ASSEMBLY
SWITCH ASSY,FLOAT
H.V ASSY
REMOTE CONTROLLER ASSEMBLY
REMOTE CONTROLLER ASSEMBLY
PWB(PCB)ASSEMBLY MAIN
DRAIN PAN ASSEMBLY
MOTOR ASSEMBLY,INDOOR
CONTROL BOX ASSY,INDOOR
TUBE ASSEMBLY,MENIFOLD
TUBE ASSEMBLY,MENIFOLD
DRAIN ASSY,TUBE
EVAPORATOR ASSEMBLY,BENDING
EVAPORATOR ASSEMBLY,BENDING
FAN ASSEMBLY,TURBO
TUBE ASSEMBLY,CAPILLARY
CAPACITOR,DRAWING
6323A10002B
6601A20001P
6609A20005H
6711A20096H
6711A20076J
6871A10370G
3087A10006A
4681A20006Z
4995A20168A
5211A20251R
5211A20251B
5251A20002B
5421A10016A
5421A10016B
5900A10003B
5211A20316S
3H00660N
6323A10002B
6601A20001P
6609A20005H
6711A20096H
6711A20076J
6871A10370H
3087A10006A
EAU31304701
4995A20168A
5211A20251W
5211A20251B
5251A20002B
5421A10016A
5421A10016B
5900A10003B
5211A20316R
3H00660M
6323A10002B
6601A20001P
6609A20005H
6711A20096H
6711A20076J
6871A10370J
3087A10006A
EAU31304702
4995A20168A
5211A20251W
5211A20251B
5251A20002B
5421A10016A
5421A10016B
5900A10003B
5211A20316R
3H00660M
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
BH/BG Chassis
359012
346810
359012-1
336610-1
336610-2
W0CZZ
249951
354210
152302
268714
263230-1
263230-2
552111
352118
330860
263230-3
267110
DESCRIPTION
PART No.
ABNH186HLAC ABNH246HLAC ABNH306GLAC ABNH366GLAC
SVC
CODE
152302
FILTER(MECH),A/C
5230A30001M
5230A30001M
5230A30001L
5230A30001L
249951
4995A14002S
4995A14002V
4995A14002T
4995A14002U
6323AQ3226G
6323AQ3226G
6323AQ3226G
6323AQ3226G
6323AQ3214E
6323AQ3214E
6323AQ3214E
6323AQ3214E
6323AQ3226V
6323AQ3226V
6323AQ3226V
6323AQ3226V
267110
6711A10008D
6711A10008D
6711A10008D
6711A10008D
268714
PWB(PCB) ASSEMBLY,MAIN
6871A00089C
6871A00089D
6871A00090B
6871A00090C
330860
3087A10008B
3087A10008B
3087A10008A
3087A10008A
336610-1 HOUSING(MECH),WRAPPER
3660A20017A
3660A20017A
3660A20019A
3660A20019A
336610-2 HOUSING(MECH),WRAPPER
3660A20018A
3660A20018A
3660A20020A
3660A20020A
346810
MOTOR ASSEMBLY,INDOOR
4681A10013C
4681A10013C
4681A10013J
4681A10013J
352118
TUBE ASSEMBLY,MENIFOLD
5211A20465G
5211A20465G
5211A20416J
5211A20416J
354210
EVAPORATOR ASSEMBLY,FIRST
5421A20100A
5421A20100A
5421A10027A
5421A10027A
5901A10026A
5901A10026A
5901A10026A
5901A10026A
FAN ASSEMBLY,BLOWER
5901A10028B
5901A10028B
5901A10028J
5901A10028A
552111
TUBE ASSEMBLY,CAPILLARY
5211A20466M
5211A20466N
5211A20693E
5211A20693E
W0CZZ
CAPACITOR,DRAWING
2A00986D
2A00986D
2A00986D
2A00986D
346810
359012-1
336610-1
336610-2
W0CZZ
249951
268714
354210
152302
352111
263230-1
263230-2
552111
352118
330860
263230-3
267110
DESCRIPTION
PART No.
ABNH486RLAC
ABNH606RLAC
SVC
CODE
152302
FILTER(MECH),A/C
5230A30017A
5230A30017A
249951
4995A14002W
4995A14002X
6323AQ3226G
6323AQ3226G
6323AQ3214E
6323AQ3214E
6323AQ3226V
6323AQ3226V
267110
6711A10008D
6711A10008D
268714
PWB(PCB) ASSEMBLY,MAIN
6871A00090D
6871A00090E
330870
3087A20025A
3087A20025A
336610-1 HOUSING(MECH),WRAPPER
3660A20044A
3660A20044A
336610-2 HOUSING(MECH),WRAPPER
3660A20045A
3660A20045A
346810
MOTOR ASSEMBLY,INDOOR
4681A10032A
4681A10032A
352118
TUBE ASSEMBLY,MENIFOLD
5211A21333A
5211A21334A
354210
EVAPORATOR ASSEMBLY,FIRST
5421A20212B
5421A20210B
5901A10051A
5901A10051A
FAN ASSEMBLY,BLOWER
5901A10053A
5901A10053A
352114
TUBE ASSEMBLY,DISTRIBUTOR
5211A21416A
5211A21417A
W0CZZ
CAPACITOR,DRAWING
0CZZA20001B
0CZZA20001B
137211
135310
268712
147581
152302
135313
146811
733010
131410
267110
W0CZZ
330870
266000
135500
346810
263230-1
131410
354212
35211B
268715
352150
268716
263230-2
W4810
359011
266000
249951
342800
330780
159830
266090
DESCRIPTION
PART No.
AVNH126ELAC
REMARKS
137211
PANEL ASSEMBLY,FRONT
3721A10092A
146811
MOTOR ASSEMBLY,STEP
4681A20055A
147581
LOUVER,HORIZONTAL
4758A10006A
152302
FILTER(MECH),A/C
5230A10009A
249951
4995A20356H
263230-1
THERMISITOR ASSEMBLY
6323A20004T
263230-2
THERMISITOR ASSEMBLY
6323AQ3226V
266000
SWITCH,PUSH
6600AP2059B
267110
6711A20096K
268712
PWB(PCB) ASSEMBLY,DISPLAY
6871A20390D
268715
PWB(PCB) ASSEMBLY,MAIN(AC)
6871A20359B
268716
PWB(PCB) ASSEMBLY,MAIN(DC)
6871A20358H
330780
CUT OFF
3078A20001A
330870
3087A10018A
342800
BEARING
4280A20004A
346810
MOTOR ASSEMBLY,INDOOR
4681A20131A
35211B
TUBE ASSEMBLY,TUBING
5211A21217B
352115
TUBE ASSEMBLY,EVAPORATOR IN
5211A25012B
352116
5211A22007B
352150
HOSE ASSEMBLY,DRIAN
5251AR2575Q
354212
EVAPORATOR ASSEMBLY,FINAL
5421A10044B
359011
5901A20008E
733010
PLATE ASSEMBLY,INSTALL
3301A10002A
W0CZZ
CAPACITOR,DRAWING
3H00671A
W4810
BRACKET
4810A21019A
131410
CHASSIS ASSEMBLY
3141A10009A
135500
COVER
3550A30201A
135310
GRILLE ASSEMBLY,DIFFUSER
3531A10248A
135313
GRILLE ASSEMBLY,INLET
3531A10247A
267110
159911
159912
135303
135314
137211
352150
146811
235450
237900
268712
135310
152302
330870
354210
346810
359010
268711
W0CZZ
166000
249951
352115
342800
35211A
263230-3
263230-2
263230-1
130911
DESCRIPTION
130911
135303
135310
135314
137211
146811
152302
159911
159912
266000
235450
237900
249951
263230-1
263230-2
263230-3
267110
268711
268712
330870
342800
346810
35211A
352115
352150
354210
359010
W0CZZ
PART No.
REMARKS
AVNH186BLAC
AVNH246BLAC
AVNH306BLAC
CABINET ASSEMBLY
GRILLE,INLET
GRILLE ASSEMBLY,DIFFUSER
GRILLE ASSEMBLY,INLET SUB
PANEL ASSEMBLY,FRONT
MOTOR ASSEMBLY,STEP
FILTER(MECH),A/C
VANE ASSEMBLY,HORIZONTAL(UPPER)
VANE ASSEMBLY,HORIZONTAL(LOWER)
3091AP2533A
5236AP1236A
3531A10272D
5237AP2817B
3720AP2767P
4681A20055A
5230AP7093A
5991AP2867B
5991AP7334C
3091AP2533A
5236AP1236A
3531A10272D
5237AP2817B
3720AP2767B
4681A20055A
5230AP7093A
5991AP2867B
5991AP7334C
3091AP2533A
5236AP1236A
3531A10272D
5237AP2817B
3720AP2767B
4681A20055A
5230AP7093A
5991AP2867B
5991AP7334C
R
R
R
R
R
R
R
R
R
SWITCH,PUSH
DISPLAY ASSEMBLY
WINDOW,DISPLAY
CONTROL BOX ASSEMBLY,INDOOR
THERMISTOR ASSEMBLY
THERMISTOR ASSEMBLY
THERMISTOR ASSEMBLY
REMOTE CONTROLLER ASSEMBLY
PWB(PCB) ASSEMBLY,MAIN
PWB(PCB) ASSEMBLY,DISPLAY
DRAIN PAN ASSEMBLY
BEARING
MOTOR ASSEMBLY,INDOOR
TUBE ASSEMBLY,SUCTION INDOOR
TUBE ASSEMBLY,EVAPORATOR IN
HOSE ASSEMBLY,DRAIN
EVAPORATOR ASSEMBLY,FIRST
FAN ASSEMBLY,CROSS FLOW
CAPACITOR DRAWING
6600AP2059A
3545AP7224E
3790AP7080A
4995A10172D
6323A30002C
6323AQ3226Y
6323A30004D
6711A20096K
6871A10186B
6871AQ3263B
3087AP7233A
3H02821B
4681AP2306M
5211AP2813G
5211AP2810Q
5251AP2460B
5421AP2812B
5901AR2351E
3H00671A
6600AP2059A
3545AP7224E
3790AP7080A
4995A10172E
6323A30002C
6323AQ3226Y
6323A30004D
6711A20096K
6871A10186C
6871AQ3263B
3087AP7233A
3H02821B
4681AP2306N
5211AP2813H
5211AP2810R
5251AP2460B
5421AP2812A
5901AR2351E
3H00671A
6600AP2059A
3545AP7224E
3790AP7080A
4995A10172F
6323A30002C
6323AQ3226Y
6323A30004D
6711A20096K
6871A10186D
6871AQ3263B
3087AP7233A
3H02821B
4681AP2306P
5211AP2813J
5211AP2810R
5251AP2460B
5421AP2812A
5901AR2351E
3H00671A
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
263230-2
263230-1
437210
435301
435512
559010
435511
137212
546810
430411
554031
554031
554160
668711
649950
552203-1
437212
561411
561410
552203-2
2. Outdoor Unit
AUUH488C
DESCRIPTION
PART No.
REMARKS
AUUH488C
135301
GRILLE,DISCHARGE
3530AP1225D
137213
PANEL ASSEMBLY,SIDE
3721A20229A
430411
BASE ASSEMBLY,WELD
3041A20047F
435511
COVER ASSY,CONTROL
3A01293X
435512
COVER ASSEMBLY,TOP
3550AP1213B
437210
PANEL ASSEMBLY,FRONT
3720AP1212B
437212
PANEL ASSEMBLY,REAR
3720AP1202C
546810
MOTOR ASSEMBLY,OUTDOOR
4681A20028J
552203-1
VALVE,SERVICE
5220A20001E
552203-2
VALVE,SERVICE
2A00499L
554031
CONDENSER ASSEMBLY,BENT
5403A20215A
554160
COMPRESSOR SET
2520UXGY2BA
559010
FAN ASSEMBLY,PROPELLER
5901A10032A
561410
COIL ASSEMBLY,REVERSING
6141AR3733R
561411
COIL ASSEMBLY,EXPANSION
6141A20011W
649950
4995A10228A
663230-1
THERMISTOR ASSEMBLY
6323A20020X
663230-2
THERMISTOR ASSEMBLY
6323A20020Z
PCB(PWB) ASSEMBLY,MAIN
6871A21317E
668711
435313
559010
552113-2
549610
552113-1
546810
554030-2
552115
554030-1
435310
554030-4
552112
554030-3
W52104
437412
447910-1
447910-2
552114
137213-2
552117-1
552117-2
552117-3
437211
668711
552114-1
55211G
552114-2
561410
552116
649950
561411
668713
330870
W6631
567480-6
552203-1
552203-2
567480-4
430410
554160
Sub PCB
567480-5
D-tube
Air
DESCRIPTION
Panel Assembly,Side
Panel Assembly,Side
Thermistor,NTC (Condenser, Air)
Thermistor,NTC (Discharge, Suction)
Thermistor,NTC (PCB Assembly Sub)
Pan Assembly,Drain
Orifice Assembly
Base Assembly,Outdoor
Grille Assembly,Front(Outdoor)
Grille Assembly,Discharge(Outdoor)
Grille Assembly,Rear(Outdoor)
Panel Assembly,Front(Outdoor)
Panel Assembly,Rear(Outdoor)
Barrier Assembly,Outdoor
Barrier Assembly,Outdoor
Motor Assembly,AC,Outdoor
Accumulator Assembly
Bracket Assembly,Motor(Outdoor)
Valve,Service
Valve,Service
Condenser Assembly,First
Condenser Assembly,First
Condenser Assembly,First
Condenser Assembly,First
Tube Assembly,Discharge(Outdoor)
Tube Assembly,Discharge(Outdoor)
Tube Assembly,Discharge(Outdoor)
Tube Assembly,Expansion
Tube Assembly,Reverse
Tube Assembly,Suction ( A )
Tube Assembly,Suction ( B )
Tube Assembly,Suction ( C )
Tube Assembly,Condenser(Out)
Tube Assembly,Condenser(Out)
Tube Assembly,Menifold
Tube Assembly,Condenser(In)
Tube Assembly,Coupling
Compressor
Fan Assembly,Propeller
Coil Assembly, Reversing valve
Coil Assembly, Expansion valve
Case Assembly,Control(Outdoor)
PCB Assembly,Main
PCB Assembly,Sub
Connector, Assembly
PART No.
REMARKS
AUUH728C
3721A10120B
3721A10120D
6323A20020Y
6323A20020Z
3Q35015S
3087A10023C
4949A10010A
3041A10058G
3531A10266D
3531A20211B
3531A11004D
3721A11009B
3721A10108C
4791A10022A
4791A20035A
4681A10014H
4849A13001B
4961A20028A
2A00469K
5220A20034B
5403A21003E
5403A21003F
5403A21003G
5403A21003X
AJR33492501
AJR33524701
5210A23344A
AJR33496501
5211A03018A
AJR33504701
AJR33504601
AJR33504501
5211A03014C
5211A03015A
5211A03019A
5211A10480D
5211A21205A
5416A90042A
5901A10029A
6141A20010N
6141A20011W
4995A10170E
6871A21317C
6871A20130V
6631A20207G
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
435313
559010
546810
549610
554030-1
554030-2
554030-3
435310
447910-1
447910-2
437412
55211G
55211G
554030-4
330870
552203-1
552203-2
658740
263230-2
554160
668711
263230-1
561411
437211
430410
561410
137213-2
DESCRIPTION
PART No.
REMARKS
AUUH1008C
137213-1
PANEL ASSEMBLY,SIDE
3721A10120B
137213-2
PANEL ASSEMBLY,SIDE
3721A10120A
263230-1
THERMISTOR ASSEMBLY
6323A20020Y
263230-2
THERMISTOR ASSEMBLY
6323A20020Z
330870
3087A10017C
349940
ORIFICE ASSEMBLY
4949A10008A
430410
BASE ASSEMBLY,OUTDOOR
3041A10049E
435310
GRILLE ASSEMBLY,FRONT
3531A10266B
435311
GRILLE ASSEMBLY,DISCHARGE
3531A20211B
435313
GRILLE ASSEMBLY,REAR
3531A11004B
437211
PANEL ASSEMBLY,FRONT
3721A10107E
437212
PANEL ASSEMBLY,REAR
3721A10108A
447910-1
BARRIER ASSEMBLY,OUTDOOR
4791A10022A
447910-2
BARRIER ASSEMBLY,OUTDOOR
4791A10023A
546810
MOTOR ASSEMBLY,OUTDOOR
4681A10014H
549610
MOUNT ASSEMBLY,MOTOR
4961A20028A
552203-1
VALVE,SERVICE
2A00469K
552203-2
VALVE,SERVICE
5220A20034B
554030-1
CONDENSER ASSEMBLY,FIRST
5403A21003C
554030-2
CONDENSER ASSEMBLY,FIRST
5403A21003D
554030-3
CONDENSER ASSEMBLY,FIRST
5403A21003W
554030-4
CONDENSER ASSEMBLY,FIRST
5403A21003B
554160
COMPRESSOR
2520UBAY2AA
559010
FAN ASSEMBLY,PROPELLER
5901A10029A
561410
6141A20010N
561411
COIL ASSEMBLY,EXPANSION
6141A20011W
649950
4995A10170D
668711
PWB(PCB)ASSEMBLY,MAIN
6871A21317D
55211G
TUBE ASSEMBLY,EXPANSION
5211A03004A
552200
VALVE,EXPANSION BODY
5220A90013A
268712
146811
152312
135314
135802
137211
268712
146811
152312
135314
137211
146811
268712
152312
135314
135802
137211
Parts List
Part No.
LOCATION
No.
REMARKS
DESCRIPTION
PT-HEC1
137211
PANEL ASSEMBLY,FRONT(INDOOR)
3721A10105N
135314
GRILLE ASSEMBLY,FRONT(INDOOR)
3531A10059A
135312
5231A10005A
146811
MOTOR ASSEMBLY,STEP
4681A20055A
268712
PWB(PCB) ASSEMBLY,DISPLAY
6871A20096J
135802
DOOR
3580A20005A
Part No.
LOCATION
No.
REMARKS
DESCRIPTION
PT-HFC
137211
PANEL ASSEMBLY,FRONT(INDOOR)
3721A10072E
135314
GRILLE ASSEMBLY,FRONT(INDOOR)
3531A10211C
135312
5231A10012A
146811
MOTOR ASSEMBLY,STEP
4681A20055A
268712
PWB(PCB) ASSEMBLY,DISPLAY
6871A20096J
Part No.
LOCATION
No.
REMARKS
DESCRIPTION
PT-HDC1
137211
PANEL ASSEMBLY,FRONT(INDOOR)
3721A10106Z
135314
GRILLE ASSEMBLY,FRONT(INDOOR)
3531A10066A
135312
5231A10004A
146811
MOTOR ASSEMBLY,STEP
4681A20055A
268712
PWB(PCB) ASSEMBLY,DISPLAY
6871A20096J
135802
DOOR
3580A20005A
P/No.: 3828A22009R
Printed in Korea