Item
Minimum requirements
IBM PC compatible computer with Intel Pentium
or above
Operating system Microsoft Windows 98/NT/XP/Vista/7
Memory
256MB or more
Hard disk
More than 1GB of free hard disk space
VGA
1024768 or higher resolution display
Others
RS-232 serial port(9-pin), USB port
System
Ordering information
CT
2P
T
A shaded (
Communication No mark
None
T
RS 485
Power supply
Output
Size
Digit
Item
J-8
4
2
100-240VAC 50/60
24VAC 50/60 / 24-48VDC
2P
1P
I
Dual preset
Single preset
Indicator
DIN W48H48mm
Y
M
DIN W72H36mm
DIN W72H72mm
4
6
9999(4digit)
999999(6digit)
CT
Counter/Timer
Programmable Counter/Timer
Specifications
CTS
CTY
4
6
6
CT6S-2P
CT6Y-2P
Dual Preset
CT4S-2P
CT6S-1P
CT6Y-1P
Single Preset
CT4S-1P
Model
Single Preset
CT6S-1
CT6Y-1
Single Preset
11mm
10mm
10mm
Digit
Size
Single Preset
8mm
7mm
7mm
Single Preset
100-240VAC 50/60Hz
Power
Supply
Single Preset
24VAC 50/60Hz / 24-48VDC
Allowable voltage range
90 to 110% of rated voltage(AC Power type)
Single Preset
Max. 12VA
Power
consumption Single Preset
AC: Max. 10VA / DC: Max. 8W
INA/INB Max. counting speed Selectable 1cps / 30cps / 1kcps / 5kcps / 10kcps
Counter
Reset signal : Selectable 1ms, 20ms
Min. input
signal width Timer
INA, INB RESET : Selectable 1ms, 20ms
Series
Digit
(A)
Photo
electric
sensor
CTM
6
CT6M-2P
CT6M-1P
CT6M-1
13mm
9mm
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
Communication specification
Protocol
Connection method
Application standard
Number of connections
Communication method
Synchronous method
Communication distance
Communication speed
Response waiting time
Start bit
Data bit
Parity bit
Stop bit
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
J-9
CT Series
Connections
CT S-2P
CT S-2P T
12VDC 100mA
INB / INH
INA
12VDC 100mA
INB / INH
INA
RESET
0VDC
OUT2
30VDC
100mA
OUT2
250VAC 5A
RESISTIVE
OUT1
250VAC 5A
RESISTIVE
A(+)
RESET
0VDC
RS485
B(-)
OUT2
OUT1
250VAC 5A 250VAC 5A
RESISTIVE RESISTIVE
+
1
CT S-1P
+
1
CT S-1P T
12VDC 100mA
INB / INH
INA
12VDC 100mA
INB / INH
INA
RESET
0VDC
OUT
30VDC
100mA
OUT
NO COM
NC
250VAC 5A
RESISTIVE LOAD
RESET
0VDC
A(+)
OUT
RS485
NO COM
NC
B(-)
250VAC 5A
RESISTIVE LOAD
CT6S-I
+
1
CT6S-I T
12VDC 100mA
INB / INH
INA
12VDC 100mA
INB / INH
INA
RESET
0VDC
RS485
A(+)
RESET
0VDC
B(-)
CT6Y-2P
SOLID
250VAC 3A
250VAC 3A
STATE OUT
RESISTIVE LOAD RESISTIVE LOAD 30VDC
100mA
NC COM
OUT
NO
OUT1
OUT2
0VDC RESET
INA
INB / INH
12VDC 100mA
OUT2
CT6Y-1P
250VAC 3A
RESISTIVE LOAD
NC COM
NO
SOLID
STATE OUT
30VDC
100mA
J-10
250VAC 3A
RESISTIVE
250VAC 3A
RESISTIVE
OUT2
OUT1
0VDC RESET
B(-)
RS485
+
1
CT6Y-1P T
SOLID
250VAC 3A STATE OUT
RESISTIVE LOAD 30VDC
NC COM
NO 100mA A(+)
OUT
A(+)
0VDC RESET
INA
INB / INH
12VDC 100mA
OUT
OUT
INA
INB / INH
12VDC 100mA
CT6Y-2P T
INA
INB / INH
12VDC 100mA
OUT
0VDC RESET
B(-)
RS485
+
1
Programmable Counter/Timer
CT6Y-I
CT6Y-I T
(A)
Photo
electric
sensor
B(-)
A(+)
RS485
0VDC RESET
INA
INB / INH
12VDC 100mA
+
1
CT6M-2P
BATCH RESET
30VDC
100mA
CT6M-1P
2
INHIBIT
RESET
0VDC
12VDC 100mA
INB
INA
B(-)
OUT
COM NC
NO
250VAC 5A
RESISTIVE
LOAD
12VDC 100mA
INB
INA
(I)
SSR/
Power
controller
(J)
Counter
BATCH RESET
(K)
Timer
2
INHIBIT
RESET
0VDC
BATCH RESET
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
RS485
BATCH
B(-)
OUT
BATCH
(N)
Display
unit
OUT
CT6M-I
(H)
Temp.
controller
CT6M-1P T
12VDC 100mA
INB
INA
A(+)
NO COM NO
250VAC 5A
RESISTIVE
LOAD
OUT2 BATCH
NO COM
250VAC 5A
RESISTIVE
LOAD
OUTPUT
COMMON
(F)
Rotary
encoder
(G)
Connector/
Socket
OUT1
BATCH RESET
RS485
OUT2
COM NC
NO
250VAC 5A
RESISTIVE
LOAD
(D)
Proximity
sensor
(E)
Pressure
sensor
2
INHIBIT
RESET
0VDC
12VDC 100mA
INB
INA
A(+)
NO COM
250VAC 5A
RESISTIVE
LOAD
+
1
OUTPUT
COMMON OUT1 OUT2 BATCH
OUT1
(C)
Door/Area
sensor
CT6M-2P T
2
INHIBIT
RESET
0VDC
12VDC 100mA
INB
INA
0VDC RESET
INA
INB / INH
12VDC 100mA
(B)
Fiber
optic
sensor
NO COM NO
250VAC 5A
RESISTIVE
LOAD
+
1
CT6M-I T
2
INHIBIT
RESET
0VDC
(O)
Sensor
controller
(P)
Switching
mode power
supply
+
1
(Q)
Stepper
motor&
Driver&Controller
2
INHIBIT
RESET
0VDC
12VDC 100mA
INB
INA
(R)
Graphic/
Logic
panel
(S)
Field
network
device
RS485
A(+)
(T)
Software
B(-)
(U)
Other
+
1
1: Source
- AC Power: 100-240VAC 50/60Hz
- AC/DC Power: 24-48VDC, 24VAC 50/60Hz
+
1
2: INHIBIT Signal
- Counter operation: If INHIBIT signal is applied,
count input will be prohibited.
- Timer operation: If INHIBIT signal is applied, time
progressing will stop.(HOLD)
J-11
CT Series
Dimensions
(unit:mm)
CTS Series
Bracket
10
48
Panel cut-out
90
2
5
4
7
4
5
10
9
6
10
J-12
31.5 +0.6
0
68 +0.7
0
CTM Series
1
6
13
3
7
8
2
5
4
12
11 9
10
9. Mode key
- By pressing MD key for 3sec (parameter setting)/ 5sec (communication)
in RUN mode, it moves to function setting mode.
- By pressing MD key in function setting mode, select function setting
mode. By pressing MD key over 3 sec., it moves to Run mode.
- By pressing MD key over 1 sec. in function setting checking mode, it
moves to Run mode.
10. Set key
: To enter into setting value(PS1, PS2) change status and shift digit
of setting value(PS1, PS2).
: To decrease setting value in setting value change mode, change
setting value in function setting mode, move down checked
value in function setting check mode.
: To increase setting value in setting value change mode, change
setting value in function setting mode, move up checked value in
function setting check mode. By pressing MD key over 1 sec.
in Run mode, enters into function setting check mode.
11. BATCH key
By pressing BA key in run mode to enter into BATCH counter
indication mode.
12. BATCH output indicator(red LED)
13. BATCH setting value checking and changing indicator
(yellow-green LED)
Lights when checking and changing BATCH setting value.
Model
Changed Notice
1. Count indicator(Red LED)
CT6Y-1P
- Run mode
CT6S-1P PS2PS There are no
PS1, OUT1
: Count mode-Indicates count value.
CT4S-1P OUT2OUT LEDs.
Timer mode-Indicates time progressing. CT6M-1P
CT6Y-I
- Function setting mode
There are no
CT6S-I
PS2PS PS1, OUT1
: Indicates function setting mode.
OUT2 LEDs.
CT6M-I
2. Preset value indicator (Yellow-Green LED)
The indicator type does not exist
- Run mode: Indicates preset value.
in CT4S model.
- Function setting mode: Indicates setting value1.
3. Key Lock : Lights when setting key lock.
4. The operation of counter indicator
5. The operation of timer indicator
TMR LED flashes when the timer is operating.
TMR LED lights when the operating time stops.
6. Check preset value and display change of it
PS1 LED lights when checking or changing the setting value1.
PS2 LED lights when checking or changing the setting value2.
7. Output(OUT1, OUT2) indicator
OUT1 lights when output1 is on.
OUT2 lights when output2 is on.
8. Reset key
By pressing RST key in Run mode, the count value is initialized and
output is returned.
By pressing RST key in BATCH counter mode,BATCH count value
resets.
6
3
7
8
9
68 +0.7
0
Min. 91
67
1
CTY Series
68 +0.7
0
Panel cut-out
85
10
72
Min. 40
30
36
86
Parts description
45.5 +0.5
0
Min. 91
77
72
CTS Series
45.5 +0.5
0
Panel cut-out
85
CTM Series
Min. 62
Min. 91
CTY Series
45
60
Min. 55
Programmable Counter/Timer
Input connections
(A)
Photo
electric
sensor
No-voltage input(NPN)
Solid-state input(Standard sensor : NPN output type sensor)
Sensor
Brown
Black 1
Counter/Timer
CT Series
Sensor
+12V
5.4
+12V
(NPN output)
(C)
Door/Area
sensor
+12V
Inner circuit
of input part
Blue
0V
Counter/Timer
CT Series
5.4
Black 1
Inner circuit
of input part
Blue
Counter/Timer
CT Series
Brown
(B)
Fiber
optic
sensor
Contact input
5.4
(D)
Proximity
sensor
Inner circuit
of input part
0V
(E)
Pressure
sensor
0V
(F)
Rotary
encoder
(G)
Connector/
Socket
Voltage input(PNP)
Solid-state input(Standard sensor : PNP output type sensor)
Sensor
Brown
Counter/Timer
CT Series
+12V
Black 1
Blue
Sensor
Counter/Timer
CT Series
Brown
5.4
(PNP output)
Counter/Timer
CT Series
(I)
SSR/
Power
controller
+12V
Inner circuit
of input part
(J)
Counter
Inner circuit
of input part
5.4
Blue
0V
+12V
Black1
Inner circuit
of input part
(H)
Temp.
controller
Contact input
5.4
0V
(K)
Timer
0V
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
Select No-voltage
input(NPN)
(P)
Switching
mode power
supply
NPN PNP
(Factory default)
Select voltage
input(PNP)
NPN
(Q)
Stepper
motor&
Driver&Controller
PNP
(R)
Graphic/
Logic
panel
(S)
Field
network
device
* Case detachment
Squeeze toward and pull toward as shown
in picture.
Please check if the power is cut off.
(T)
Software
<CTS Series>
<CTY Series>
<CTM Series>
(U)
Other
J-13
CT Series
Output connections
Contact output
Solid-state output
Counter/Timer
CT Series
Counter/Timer
CT Series
1
Load
(Power of load)
(-)
Load
Communication
Timer
Counter
Factory default
Factory default
UP/Down-C (UD-C)
F (F)
30cps (30)
TOTAL (TOTAL)
Hold (HOLD)
100ms (0)10)
------
20ms (20)
NPN (NPN)
6digit type : -.-----, 4digit type : -.---
6digit type : 1.000004digit type : 1.000
000000
Clear (SLR)
Lock off (lOFF)
1000 (1000)
5000 (5000)
6Digit type: 0.001s-999.999s, 4Digit type: 0.001s-9.999s
UP (UP)
TOTAL (TOTAL)
CLEAR (SLR)
OND (OND)
Hold (HOLD)
100ms (0)10)
NPN (NPN)
20ms (20)
Lock off (lOFF)
1000 (1000)
5000 (5000)
01 (001)
9600bps (96)
NONE (NONE)
2 (2)
20ms (20)
Enable (ENA)
Error display
Error display
EEP
PS1
PS2
J-14
FAIL
Power
for load
(DC)
Use proper load and power for load not to excess ON/OFF
capacity(30VDC Max. 100mA max.) of solid state output.
Be sure not to apply reverse polarity of power.
1: When use inductive load(Relay etc), surge absorber
(Diode, varistor etc) must be connected between both
sides of the load.
Parameter
Input mode (IN)
Output mode (OUtM)
CPS (CPS)
Indication mode (indicator type)(DSpM)
OUT2 output time (OUt2)
OUT1 output time (OUt1)
Decimal point (DP)
Min. reset time (RST)
Input logic (SIG)
Prescale decimal point (ScDP)
Prescale value (SCL)
Start Point setting (STRT)
Counting memory (DATA)
Lock key (LOCK)
Preset value 1 (PS1)
Preset value 2 (PS2)
Time range (HOUR/MIN/SEC)
Up/Down mode (U-D)
Indication mode(Indicator type)(DSpM)
Memory protection(Indicator type) (DATA)
Output mode (OUtM)
OUT2 output time (OUT2)
OUT1 output time (OUT1)
Input logic (SIG)
Input signal time (ImT)
Lock key (LOCK)
Preset value 1 (PS1)
Preset value 2 (PS2)
Communication address (ADDR)
Communication speed (BPS)
Communication parity (PRTY)
Communication stop bit (STP)
Response waiting time (RSWT)
Communication writing (COmY)
(+)
Errors
Output status
How to return
OFF
Power on again
Programmable Counter/Timer
Operations and functions
RESET
BATCH RESET
1
Change of BATCH
setting value.
(A)
Photo
electric
sensor
1
Change of
preset
RUN
mode
BATCH counter
indication mode
BATCH counter is
available for
CT6M-1P/2P only.
3sec. 5sec.
1sec.
1sec.
(B)
Fiber
optic
sensor
Function setting
check mode
(C)
Door/Area
sensor
(D)
Proximity
sensor
3sec.
Function
setting mode
(F)
Rotary
encoder
Change of preset(Counter/Timer)
Even if changing the preset value, input operation and output control will continue. In addition, the preset value could
be set to 0 and 0 preset value turns ON. According to output mode, preset value could not be set to 0. (When setting to 0,
preset value "0" will flash 3 times.)
1.
2.
(E)
Pressure
sensor
(G)
Connector/
Socket
3.
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
Press key to save set value after changing the setting value. Then, it moves to next parameter or returns
to RUN mode. However, if no key is touched for 60 sec., it will return to RUN mode without being saved.
and
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
keys.
Setting value 1(PS1) and setting value 2(PS2) are displayed each time pressing
(In timer, it is available for
output mode.)
(O)
Sensor
controller
(P)
Switching
mode power
supply
Reset
/CT6M-2P
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
model only)
In BATCH counter indication mode, 'BATCH counter value' is displayed in count indicator and 'BATCH counter
setting value' is displayed in preset indicator.
(S)
Field
network
device
If pressing
key in Run mode, it will enter into BATCH counter indication mode.
1.
(T)
Software
2.
It enters into
settingvalue change
mode using key.
(BA.S lights, first digit
of setting value flashes.)
(U)
Other
CT Series
BATCH counter operation
Power
ON
OFF
Preset output
Batch Reset
999999
Batch setting value
0
BA.O LED
ON
OFF
Batch ON
output OFF
BATCH output
If input signal is applied while changing BATCH setting value, counting operation and output control will be performed.
If BATCH count value equals to BATCH setting value, BATCH output will be ON and maintain ON status until BATCH reset
signal is applied.
When the power is cut off then resupplied in status of BATCH output is ON, BATCH output maintains ON status until
BATCH reset signal is applied.
If pressing reset button or applying the signal to BATCH reset terminal on the back side panel, BATCH counting value will
be reset. When selecting voltage input(PNP), short no. 10 and no. 14 terminals, or when selecting no-voltage input(NPN),
short no. 11 and no. 14 terminals to reset.
When BATCH reset is applied, BATCH counting value maintains at 0 and BATCH output maintains in the OFF status.
BATCH output
Control
output
(OUT)
CT6M-1P4
Control box
Preset value = 5
BATCH output
lamp
Control signal
for packing
Control signal
for conveyor
Third
Second
First
box
box
box
Current BATCH count value = 3
J-16
Timer
Fills milk into the bottle for 3sec.(setting time) When 500
bottles are filled, BATCH counting finish lamp is turned on.
(Setting time : 3sec., BATCH setting value : 500)
Operation valve
(Open valve
for 3sec.)
BATCH output
Control
output
CT6M1P4
Control the
operation valve
Bottle sensing
sensor
Productivity :
500bottels
Lamp on when
it is completed.
BATCH counting
finish lamp
Control
box
Programmable Counter/Timer
Flow chart for function setting mode
(A)
Photo
electric
sensor
Run mode
3sec.
3sec.
5sec.
Parameter group1
Counter/Timer
(COUN)
(GRp2)
(C-T)
Input mode
Time range
(IN)
Output mode
(OUtM)
Indication mode
1
(DSpM)
(CPS)
2 3
Decimal point
(DP)
(HOUR/MIN/SEC)
2
(RST)
Up/Down mode
(U-D)
1
Indication mode
(DSpM)
Memorize
counting value
(DATA)
Output mode
(OUtM)
(OUT1)
Input logic
(SIG)
(SIG)
Prescale decimal
point
(ScDP)
Prescale value
(RST)
(LOCK)
Communication
(E)
Pressure
sensor
Com. address
(ADDR)
Input logic
Lock key
(D)
Proximity
sensor
(F)
Rotary
encoder
Com. speed
(BPS)
(G)
Connector/
Socket
Com. parity
(PRTY)
(H)
Temp.
controller
(I)
SSR/
Power
controller
(STP)
Response
waiting time
(J)
Counter
(RSwT)
(K)
Timer
Com. writing
(COmW)
(L)
Panel
meter
(DATA)
(C)
Door/Area
sensor
Timer
(T1ME)
3sec.
Parameter group2
(GRp1)
Counter
(B)
Fiber
optic
sensor
1: Indicator
2: Output type
3: If changing the setting
value of function, OUT1,
OUT2 will turn OFF and
return to Run mode, then
present value resets.
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
Lock key
(LOCK)
(P)
Switching
mode power
supply
Counter
- Single preset model has no "OUT1 output setting time" setting function
mode and OUtT is displayed in "OUT2 output time" setting function mode.
- In case of DN, DN-1, DN-2 input mode, there is no "Start Point value" setting
function mode.
- In case of F or N output mode, there is no "OUT2 output time" setting function
mode.(Fixed to HOLD)
- In case of S, T or D output mode, there is no "OUT2 output time" setting
function mode.
Timer
- In case of FLk1, FLk2 or INtG output mode and OND, OND1, OND2 output
mode of single preset model, OUtT is displayed in "OUT2 output time" function
setting mode and there is no "OUT1 output time" function setting mode.
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
- The output modes except for OND, ONd1, ONd2 and INt2 output mode there is no
"OUT1 output time" function setting mode.
If changing setting value of parameter group1, display value and output will be initialize.
Press key over 3sec./5sec. in RUN mode to enter into parameter 1 group/ parameter 2 group.
Press key over 3 sec. in function setting mode to return RUN mode.
Input operation and output control can be set in function setting mode.
If changing set value of 3 marked parameters in function setting mode, OUT1 and OUT2 output will be turned OFF and
then the current value is reset.
Parameter 2 group is not available to non-communication models.
J-17
(U)
Other
CT Series
Parameter setting(Counter)
(
Setting mode
How to set
Counter/Timer
C-T
COUN
Input mode
IN
UD-C
CONE: COUNTER
TIME: TIMER
TIME
UP
or
UP-1
UP-2
DN
DN-1
DN-2
UD-A
UD-B
In case that output mode is F, N there is no "OUT2 output time" setting mode. (Fixed to HOLD)
If output mode is set to D when max. counting
UD-A, UD-B, UD-C input mode
N
F
C
R
K
P
Q
A
S
T
D speed is set to 5Kcps, 10Kcps, max. counting
speed is automatically set to 30cps. (Factory
default setting)
In case of the indicator
In case of the indicator, indicate mode selection (DSpM)is displayed.
HOLD
TOTAL
It is added that the function which can set the preset value when selecting
HOLD.(Refer to J-22 page 'Counter operation of the indicator'.)
30
1K
SY
10K
Counting speed is that of one by one(1:1) duty ratio of INA or INB input signal,
and it is applied in INA and INB at thesame time.
In case of setting D in output mode, you can choose 1cps, 30cps, 1Kcps.
1
Decimal point
DP
6digit type
------
-----.-
4digit type
------.-
--.--
Input logic
SIG
1
Prescale
decimal point
ScDP
20
----.--.---
---.---
--.----
-.-----
unit: ms
6digit type
Prescale decimal point position is not set below the decimal
point setting digits (DP).
4digit type
Prescale value
SCL
Setting range of Start Point value (Connected with decimal point setting)
6digit type: 0.00000 to 999999
4digit type: 0.000 to 9999
Refer to the J-20 page ' Start Point function'.
Memory protection
DATA
Lock key
LOCK
CLR
REC
LOFF
LOc1
LOc3
LOc2
Programmable Counter/Timer
Input operation mode(Counter)
Input mode
Count chart
Operation
INA H
H
INB
L
No
counting
(UP)
Count
0
value 0
H
INA
L
UP-1
INB H
L
Count
value 0
n-1
n-2
INA H
L
DN-1
(Down-1)
Count
value
INA
DN-2
n-1
(Up/Down-A)
Count
value
n-5
n-6
(H)
Temp.
controller
(I)
SSR/
Power
controller
n-4
n-4
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
n-5
(O)
Sensor
controller
n-3
(N)
Display
unit
(P)
Switching
mode power
supply
n-2
H
L
(M)
Tacho/
Speed/ Pulse
meter
n-5
No counting
n-1
(L)
Panel
meter
n-3
(K)
Timer
n-7
(G)
Connector/
Socket
No counting
n-2
H
INA L
INB
n-4
H
L
INB H
L
Count
value
n-3
(Down-2)
UD-A
INB H
L
(F)
Rotary
encoder
No counting
n
Count
value
(D)
Proximity
sensor
(J)
Counter
INB H
L
(Down)
(C)
Door/Area
sensor
INA H
L
DN
No counting
(Up-2)
INA H
L
UP-2
0 0
(E)
Pressure
sensor
No counting
(Up-1)
H
INB L
Count
value
(B)
Fiber
optic
sensor
No counting
UP
(A)
Photo
electric
sensor
(S)
Field
network
device
(T)
Software
(U)
Other
J-19
CT Series
Input operation mode(Counter)
Input mode
Count chart
Operation
INA H
L
INB H
L
UD-B
(Up/Down-B)
Count
value
INA H
L
INB H
L
UD-C
BBBB
(Up/Down-C)
Count
value
signal width should be over min. signal width and signal width should be over a half min. signal width.
If not, 1 will occur.
Min. signal width by counting speed
The meaning of "H" and "L"
Voltage input (NPN) No-Voltage input (PNP)
H
5-30VDC
Short circuit
0-2VDC
Open
Counting
speed
1cps
30cps
1kcps
5kcps
10kcps
Min. signal
width
500
16.7
0.5
0.1
0.05
INA High
(INB) Low
ON
OFF
Ton
Toff
ON
OFF
Prescale function(Counter)
This function is to set and indicate calculated unit for actual length, liquid measure, position etc. It is called "Prescale value"
for measured length, measured liquid, measured position, etc per 1 pulse.
For example, P is the number of pulses per 1 revolution of a rotary encoder and L is the desired length to be measured.
Prescale value is [the desired length (L)]/[the number of pulses (P) per 1 revolution of the rotary encoder.].
It is the length per 1 pulse of a rotary encoder.
Ex) Control length by the counter and the rotary encoder
Roller
Cutter
Rotary encoder
Prescale value =
Motor
Motor controlling
system
=
Counter
= 0.069mm/pulse
To control conveyor position in 0.1mm, set the decimal point to tenth place(-----.-) in decimal point setting mode(DP) and
set the prescale decimal point to thousandth place(---.---) in prescale decimal point setting mode(ScDP)Then set prescale
value "0.069" in prescale setting mode (SCL).
Programmable Counter/Timer
Output operation mode(Counter)
Output
mode
F
(F)
Input mode
Up, Up-1, 2
Down, Down-1, 2
Up/Down A, B, C
RESET
999999
PRESET2
PRESET1
0
OUT1
OUT2
(OUT)
N
(N)
C
(C)
RESET
999999
PRESET2
PRESET 1
0
OUT1
OUT2
(OUT)
RESET
999999
PRESET2
PRESET 1
0
OUT1
OUT2
(OUT)
R
(R)
K
(K)
P
(P)
RESET
999999
PRESET2
PRESET1
0
OUT1
OUT2
(OUT)
RESET
999999
PRESET2
PRESET1
0
OUT1
OUT2
(OUT)
RESET
999999
PRESET2
PRESET1
0
OUT1
OUT2
(OUT)
Q
(Q)
RESET
999999
PRESET2
PRESET1
0
OUT1
OUT2
(OUT)
A
(A)
RESET
999999
PRESET2
PRESET 1
0
OUT1
OUT2
(OUT)
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
Operation
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(R)
Graphic/
Logic
panel
The single preset type output(OUT) is operated as OUT2 of dual preset type.
OUT1 output could be set to 0 in all modes and 0 value output turns ON.
OUT2 output could not set to 0 in C(C). R(R), P(P) or Q(Q) output mode.
J-21
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(S)
Field
network
device
(T)
Software
(U)
Other
CT Series
Output operation mode(Counter)
Output mode Up/Down - A, B, C
Operation
RESET
999999
PRESET2
PRESET1
0
-99999
OUT1
OUT2
(OUT)
S
(S)
RESET
999999
PRESET2
PRESET1
0
-99999
OUT1
T
(T)
OUT2
(OUT)
RESET
999999
PRESET2
PRESET1
0
D
(D)
-99999
OUT1
OUT2
(OUT)
The single preset type output(OUT) is operated as OUT2 of dual preset type.
The dual preset model OUT1 output is operated as one-shot or retained output.(except S, T, D mode)
OUT1 output could be set to 0 in all modes and 0 value output turns ON.
OUT2 output could not set to 0 in C(C), R(R), P(P) or Q(Q) output mode.
TOTAL
(TOTAL)
HOLD
Count chart
In case of input mode is Up
(Up, Up-1, Up-2)
RESET
RESET
999999
999999
-99999
RESET
999999
PRESET
999999
PRESET
(HOLD)
0
Operation
Count value increases or decreases
until RESET input is applied.
When reaching max. count value or
min. count value, it will be reset and
count simultaneously.
In case of the input mode is Command input (UD-A), Individual input(UD-B), Phase difference input(UD-C).
RESET
999999
0
-99999
J-22
In case of UP/DOWN (UD-A, UD-B, UD-C) input mode, indication mode (DSpM) of the configuration is not displayed.
Programmable Counter/Timer
Parameter setting(Timer)
Setting mode
How to set
Counter/Timer
C-T
COUN
or
(B)
Fiber
optic
sensor
COUN: COUNTER
TIME: TIMER
TIME
(C)
Door/Area
sensor
6digit type
SEC
99(999
SEC
999(99
0.001s to
999.999s
0.01s to
9999.99s
HOUR
9999(9
0.1h to
99999.9h
Timer range
HOUR/MIN/SEC
UP/DOWN mode
U-D
Indication mode
DSpM
Memory protection
DATA
Output mode
OUtM
SEC
9999(9
SEC
999999
M S
995(99
M S
9995(9
0.1s to
99999.9s
1s to
999999s
0.01s to
99m59.99s
0.1s to
999m59.9s
H M
999959
H M 5
995959
MIN
999999
MIN
9999(9
M 5
999959
1m to
9999h59m
1s to
99h59m59s
1m to
999999m
0.1m to
99999.9m
1s to
9999m59s
SEC
9(99
SEC
99(9
0.001s to
9.999s
0.01s to
99.99s
0.1s to
999.9s
UP
OND
SEC
9959
1s to
9999s
1s to
99m59s
HOUR
9999
H M
9959
MIN
9999
MIN
99(9
1h to
9999h
1m to
99h59m
1m to
9999s
0.1m to
999.9m
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
HOLD
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
ONtD
ONd2
FLK
FLk1
INTG
NFd1
NFD
OFD
FLk2
INt2
Input logic
S1G
LOc3
LOc2
(O)
Sensor
controller
INt1
[unit: ms]
(N)
Display
unit
INT
LOc1
(M)
Tacho/
Speed/ Pulse
meter
ONd1
LOFF
(L)
Panel
meter
REC
20
(H)
Temp.
controller
DN
TOTAL
CLR
SEC
9999
Lock key
LOCK
(D)
Proximity
sensor
4digit type
SEC
(999
(A)
Photo
electric
sensor
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
J-23
CT Series
One-shot output
Retained output
Operation
POWER
INA(START)
INH(INHIBIT)
OND
(OND)
RESET
Setting time2
UP
Setting time1
Display
Down
INA
Setting time2
T1
Setting time1
0
OUT1
T2
OUT2
(OUT)
OUT1
OUT2
ONd1
(OND.1)
Setting time2
UP
Display
Down
Setting time1
0
Setting time2
INA
T1
Setting time1
OUT1
T2
OUT2
(OUT)
OUT1
OUT2
ONd2
UP
(OND.2)
Display
Down
HOLD
0
Setting time2
POWER
Setting time1
0
T1
OUT1
T2
OUT2
(OUT)
OUT1
OUT2
Flicker(Power Reset)
POWER
INA(START)
INH(INHIBIT)
RESET
T.off
setting time
T.on
setting time
FLK
(FLK)
UP
Display
Down
0
T.off
setting time
POWER
T.on
setting time
0
INA
T.off
OUT2(OUT)
a t-a
T.on Ta
Tb T.on
T.off T.on
T.off T.on
T.off
T.off
T.on
T.off
OUT2
(OUT)
Power Reset: There is no memory protection.(Initializes the display value when power is off)
Power Hold: There is memory protection.(Memorizes the display value at the moment of power off, indicates the memorized
display value when power is resupplied.)
J-24
Programmable Counter/Timer
Output operation mode(Timer)
Operation
Hold output
POWER
INA(START)
INH(INHIBIT)
RESET
Setting time
Up
Display
Down
FLk1
(FLK.1)
INA
OUT2
(OUT)
POWER
INA(START)
INH(INHIBIT)
RESET
Setting time
Up
Display
Setting time
INA
OUT2
(OUT)
Down
POWER
INA(START)
INH(INHIBIT)
RESET
Setting time
Up
Display
Down
FLk2
(FLK.2)
INA
OUT2
(OUT)
POWER
INA(START)
INH(INHIBIT)
RESET
Display
Down
Setting time
0
T-c
Hold
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(Q)
Stepper
motor&
Driver&Controller
T:Setting time
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
POWER
Setting time
0
t
OUT2(OUT)
(I)
SSR/
Power
controller
(P)
Switching
mode power
supply
One-Shot output
(H)
Temp.
controller
(K)
Timer
POWER
Setting time
OUT2(OUT)
Up
Hold output
(G)
Connector/
Socket
T:Setting time
OUT2(OUT)
(D)
Proximity
sensor
(J)
Counter
POWER
(C)
Door/Area
sensor
(F)
Rotary
encoder
T
T:Setting time
OUT2(OUT)
One-Shot output
(B)
Fiber
optic
sensor
(E)
Pressure
sensor
POWER
0
Setting time
(A)
Photo
electric
sensor
t-a
INA
OUT2
(OUT)
T-c
Hold
(U)
Other
T:Setting time
Power Reset: There is no memory protection.(Initializes the display value when power is off)
Power Hold: There is memory protection.(Memorizes the display value at the moment of power off, indicates the memorized
display value when power is resupplied.)
J-25
CT Series
Output operation mode(Timer)
Output mode Input mode
Interval (Power Reset)
POWER
INA(START)
INH(INHIBIT)
RESET
INT
(INT)
Setting time
Up
0
Display
Setting time
Down
0
OUT2(OUT)
INt1
(INT.1)
RESET
Setting time
Up
0
Display
Setting time
Down
0
Operation
1) Control output turns ON and time starts
when INA signal turns ON.
2) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
3) When it reaches setting time, indication
value and control output are reset
automatically.
4) Control output is ON when time is
progressing.
POWER
INA
POWER
INA(START)
INH(INHIBIT)
RESET
INt2
(INT.2)
Setting time1
Up
T
T:Setting time
OUT2(OUT)
OUT2
(OUT)
T
T:Setting time
Setting time2
0
Display
Setting time2
Down
Setting time1
0
OUT1
OUT2
INA
T1
OUT1
OUT2
T2
t1
t2
Power Reset: There is no memory protection.(Initializes the display value when power is off)
Power Hold: There is memory protection.(Memorizes the display value at the moment of power off, indicates the memorized
display value when power is resupplied.)
J-26
Programmable Counter/Timer
Output operation mode(Timer)
Output mode Input mode
Signal Off Delay1(Power Reset)
POWER
INA(START)
INH(INHIBIT)
RESET
OFD
(OFD)
Setting time
Up
Display
Down
0
Setting time
0
OUT2(OUT)
NFD
(NFD)
On_Delay
Off_Delay
Up
Display
Down
0
On_Delay
Off_Delay
0
Operation
1) If INA is ON, control output remains
ON. (except when power is off and
reset is on)
2) When INA signal is OFF, time processes.
3) When it reaches setting time, indication value and control output are
reset automatically.
POWER
INA
OUT2
(OUT)
T: Setting time
T1
OUT2
(OUT)
POWER
INA(START)
INH(INHIBIT)
RESET
NFd1
Up
(NFD.1)
Display
Up
Down
Display
Down
On_Delay
Off_Delay
0
On_Delay
Off_Delay
0
OUT2(OUT)
OUT2
(OUT)
T1
T2
POWER
INTG
(INTG)
Up
Display
Down
0
Setting time
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(R)
Graphic/
Logic
panel
INA(START)
RESET
Setting time
(E)
Pressure
sensor
(Q)
Stepper
motor&
Driver&Controller
T1: On_Delay
T2: Off_Delay
INH(INHIBIT)
(D)
Proximity
sensor
(K)
Timer
T1: On_Delay
T2: Off_Delay
(C)
Door/Area
sensor
(J)
Counter
T2
OUT2(OUT)
(B)
Fiber
optic
sensor
(F)
Rotary
encoder
(A)
Photo
electric
sensor
0
OUT2(OUT)
Power Reset: There is no memory protection.(Initializes the display value and the output status when re-supplying the power.)
Power Hold: There is memory protection.(It memorizes the status of power off. When re-supplying the power, it returns
the memorized display value and the output status.)
J-27
(S)
Field
network
device
(T)
Software
(U)
Other
CT Series
Timer operation of the indicator(CT6S-I, CT6Y-I, CT6M-I)
When memory protection setting is OFF
POWER
INA(START)
INH(INHIBIT)
Up
Display
TOTAL
(TOTAL)
Down
RESET
Max.
time range
0
Max.
time range
0
When memory protection setting is ON
POWER
INA(START)
INH(INHIBIT)
Up
Display
Down
RESET
Max.
time range
0
Max.
time range
0
When memory protection setting is OFF
POWER
INA(START)
INH(INHIBIT)
RESET
Up
Display
HOLD
(HOLD)
Down
Setting time
0
Setting time
0
Setting time
0
Setting time
Down
0
When memory protection setting is OFF
POWER
INA(START)
INH(INHIBIT)
RESET
Up
Display
ONtD
(On Time
Display)
Setting time
0
Setting time
Down
0
When memory protection setting is ON
POWER
INA(START)
INH(INHIBIT)
RESET
Setting time
Up
Display
0
Setting time
Down
0
J-28
Programmable Counter/Timer
Timer '0' time setting
(A)
Photo
electric
sensor
DOWN mode
INA(START)
(B)
Fiber
optic
sensor
(E)
Pressure
sensor
OUT1
OUT1
OUT2
OUT2
DOWN mode
INA(START)
(F)
Rotary
encoder
(G)
Connector/
Socket
INA(START)
RESET
Setting time1
RESET
Setting time2
(H)
Temp.
controller
OUT1
OUT1
(I)
SSR/
Power
controller
OUT2
OUT2
RESET
Setting time 1
RESET
Setting time1
OUT1
OUT1
OUT2
OUT2
Up
OUT2
(OUT)
(O)
Sensor
controller
Off_Delay
0
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
OUT2
(OUT)
(R)
Graphic/
Logic
panel
INA(START)
RESET
RESET
Display On_Delay
0
Down
(N)
Display
unit
Display Off_Delay
0
Down
INA(START)
On_Delay
0
(M)
Tacho/
Speed/ Pulse
meter
RESET
OUT2
(OUT)
(L)
Panel
meter
INA(START)
RESET
Display On_Delay
0
Down
(K)
Timer
INA(START)
On_Delay
0
(J)
Counter
UP mode
DOWN mode
POWER
Up
(D)
Proximity
sensor
Setting time 2
Setting time2
Up
(C)
Door/Area
sensor
Up
(S)
Field
network
device
Off_Delay
0
Display Off_Delay
0
Down
(T)
Software
OUT2
(OUT)
(U)
Other
UP mode: When the timer setting value1 is greater than the setting value 2, OUT1 output does not turn ON.
DOWN mode: When the timer setting value1 is greater than the setting value 2, OUT1 output does not turn ON.
If the setting value 1 is same as the setting value2 and START signal is applied, OUT1 output turns ON
immediately.
J-29
CT Series
Communication mode
Parameter setting
Setting mode
or
How to set
Setting range of com. address: 1 to 127
: To shift flashing digits of Com. address.
If the same address is applied during multicom.,
: To change the flashing digits.
it will not work correctly.
Com. address
(ADDR)
Com. speed
(BPS)
24
Com. parity
(PRTY)
NONE
48
96
192
EVEN
384
2400/4800/9600/19200/38400bps
NONE: None EVEN : Even number ODD: Odd number
ODD
2
Setting range according to com. speed.
: To shift flashing digits position of com.
response waiting time.
: To change the flashing digits position
value.
esponse
waiting time
(RSwT)
Com. write
(COmW)
ENA
2400bps
4800bps
9600bps
19200bps
38400bps
16ms to 99ms
8ms to 99ms
5ms to 99ms
5ms to 99ms
5ms to 99ms
DISA
RS232C
RxD - RxD
TxD - TxD
GND - GND
GND
V(12-24VDC)
Terminating
resistance
B(-)
B(1)
A(+)
RS232C Cable
Computer
A(+) B(-)
B(-)
ON
A(+)
OFF
A(+) B(-)
CT Series
#31
A(+) B(-)
CT Series CT Series
#01
#02
CT Series
#30
A(+)
It is recommended to use communication converter, RS485 to Serial converter(SCM-38I, sold separately), USB to
RS485 converter(SCM-US48I, sold separately). Please use a proper twist pair for RS485 communication.
Data
Data
CRC16
Command
Address code
B
CRC16
CT Series
Command
Data
CRC16
Command
Address code
Upper system
Address code
Programmable Counter/Timer
Communication command and block
(A)
Photo
electric
sensor
Query(Master)
Starting
Slave
Address
Address Function
High
Low
1Byte 1Byte 1Byte 1Byte
No. of Points
High
1Byte
Low
1Byte
Error Check
(CRC 16)
Low
High
1Byte 1Byte
CRC 16
Data
Data
Data
1Byte
1Byte
1Byte
1Byte
Error Check
(CRC 16)
Low
High
1Byte 1Byte
CRC 16
No. of Points
High
1Byte
Low
1Byte
Error Check
(CRC 16)
Low
High
1Byte 1Byte
CRC 16
Response(Slave)
Error Check
Data
Data
Slave Function Byte Data
(CRC 16)
Address
Count
High Low High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
CRC 16
Force Data
High
1Byte
Low
1Byte
Error Check
(CRC 16)
Low
High
1Byte 1Byte
CRC 16
Response(Slave)
Coil Address
Slave
Function
Address
High
Low
Force Data
High
Low
Error Check
(CRC 16)
Low
High
1Byte
1Byte
1Byte
1Byte
1Byte
1Byte
1Byte
1Byte
CRC 16
Register
Slave
Address
Address Function
High
Low
Preset Data
High
Low
Error Check
(CRC 16)
Low
High
1Byte
1Byte
1Byte
1Byte
1Byte
1Byte
Byte
Count
Data
Error
Check
(CRC 16)
Data
Response(Slave)
Slave
Function
Address
Starting Address
No. of Register
Error Check
(CRC 16)
High
Low
High
Low
Low
High
1Byte
1Byte
1Byte
1Byte
1Byte
1Byte
1Byte
1Byte
(G)
Connector/
Socket
CRC 16
(H)
Temp.
controller
Query(Master)
(I)
SSR/
Power
controller
Starting Address
Slave
Function
Address
High
Low
No. of Points
Error Check
(CRC 16)
High
Low
Low
High
01 H
00 H
02 H
EC H
0B H
00 H
01 H
(J)
Counter
(K)
Timer
Response(Slave)
Slave
Address
Function
01 H
01 H
(L)
Panel
meter
Error Check
(CRC 16)
Low
High
D0 H
49 H
Data
Byte Count (00003 to
00001)
01 H
02 H
(M)
Tacho/
Speed/ Pulse
meter
Query(Master)
Starting Address
Slave
Function
Address
High
Low
No. of Points
High
Low
Error Check
(CRC 16)
Low
High
0F H
00 H
02 H
00 H
04 H
03 H
EB H
95 H
Error Check
(CRC 16)
Data
Data
High
Low
High
Low
Low
High
0F H
E2 H
40 H
00 H
01 H
E2 H
28 H
(T)
Software
1Byte
(U)
Other
Register
Slave
Address
Address Function
High
Low
Preset Data
High
Low
Error Check
(CRC 16)
Low
High
1Byte
1Byte
1Byte
1Byte
1Byte
1Byte
(Q)
Stepper
motor&
Driver&Controller
(S)
Field
network
device
CRC 16
Response(Slave)
1Byte
(O)
Sensor
controller
(R)
Graphic/
Logic
panel
Slave
Byte
Function
Count
Address
04 H
(N)
Display
unit
(P)
Switching
mode power
supply
04 H
(D)
Proximity
sensor
(F)
Rotary
encoder
6) Application
01 H
(C)
Door/Area
sensor
(E)
Pressure
sensor
Response(Slave)
1Byte
No. of
Register
CRC 16
Byte
Slave
Address Function Count
1Byte
Starting
Slave
Address
Function
Address
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Response(Slave)
1Byte
(B)
Fiber
optic
sensor
1Byte
CRC 16
J-31
CT Series
Modbus Mapping Table
1) Reset/Output
No(Address)
00001(0000)
00002(0001)
00003(0002)
Func
01/05
01
01
00004(0003) 01
4) Monitoring data
Explanation
Reset
OUT2 output
OUT1 output
For BATCH
00005(0004) 01/05 BATCH resets 0:OFF 1:ON
output model
3) Product Information
No(Address)
30001~30100
30101(0064)
30102(0065)
30103(0066)
30104(0067)
30105(0068)
30106(0069)
30107(006A)
30108(006B)
30109(006C)
30110(006D)
30111(006E)
30112(006F)
30113(0070)
30114(0071)
30115(0072)
30116(0073)
30117(0074)
Func
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
30120(0077) 04
Explanation
Reserved
Product number H
Product number L
Hardware version
Software version
Model no. 1
Model no. 2
Model no. 3
Model no. 4
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Coil Status
Start Address
Coil Status
Quantity
Input Status
Start Address
30121(0078) 04
30122(0079) 04
30118(0075) 04
Notice
Model ID
"CT"
"6M"
"-2"
"PT"
0000
04
31006(03ED) 04
31007(03EE)
31008(03EF)
04
31009(03F0)
31010(03F1)
31011(03F2)
31012(03F3)
04
04
31013(03F4) 04
Setting range
Notice
0:OFF 1:ON
Bit 5
0:OFF 1:ON
Bit 6
0:OFF 1:ON
Bit 7
0:OFF 1:ON
Bit 10
0:OFF 1:ON
Bit 11
0:OFF 1:ON
Bit 12
0:OFF 1:ON
Bit 13
0:OFF 1:ON
Bit 14
0:OFF 1:ON
Bit 15
0 to 999999
For BATCH
output
model
Counter
-99999 to
Present value 6digit type: 999999
Use counter
of
and timer
4digit
type:
-999
to
9999
counter/timer Timer: Within time setting in common
range
Counter:
Counter: decimal point 40058 Data
of display value Timer:
Timer: Time range
40102 Data
Counter
6digit type: -99999 to
Use counter
PS(2)
999999
timer
setting value 4digit type: -999 to 9999 and
Timer: Within time setting in common
range
Counter
6digit type: -99999 to
Use counter
PS1
999999
timer
setting value 4digit type: -999 to 9999 and
Timer: Within time setting in common
range
Setting value
Use counter
of BATCH
0 to 999999
and timer
counter
in common
Checking the 0: NPN, 1 : PNP
input logic
Display unit
0000
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit4 Bit 3 Bit 2 Bit 1 Bit 0
0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0
0 or 1 0 or 1 0 or 1 0
0000
-
30124(007B) 04
Holding Register
Start Address
Holding Register
Quantity
Input Register
Start Address
30125(007C) 04
30119(0076) 04
30123(007A) 04
J-32
0064
Explanation
Setting range
Counter
PS2 setting value
PS setting value 6digit type: 0 to
999999
4digit type: 0 to 9999
PS1 setting
Timer: Within time
value
setting range
BATCH counter
0 to 999999
setting value
Notice
Use counter
and timer
in common
Use counter
and timer
in common
Use counter
and timer
in common
Programmable Counter/Timer
6) Function setting mode (Counter group)
No(Address)
40051(0032)
40052(0033)
Func
03/06/16
03/06/16
40053(0034)
03/06/16
40054(0035)
03/06/16
40055(0036)
03/06/16
40056(0037)
40057(0038)
03/06/16
03/06/16
40058(0039)
03/06/16
40059(003A)
03/06/16
40060(003B)
03/06/16
40061(003C)
40062(003D)
40063(003E)
40064(003F)
40065(0040)
40066(0041)
03/06/16
03/06/16
03/06/16
03/06/16
Explanation
Counter/Timer(C-T)
Setting range
1: COUN 1: TIME
Input mode(IN)
0: UP
1: UP-1
2: UP-2
3: DN
4: DN-1
(A)
Photo
electric
sensor
Notice
Use counter and timer in common
5: DN-2
6: UD-A
7: UD-B
8: UD-C
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
unit: 10
unit: 10
4digit type 0: ---1: ---.- 2: --.-- 3: -.--unit: ms
4digit type
1: ---.- 2: --.-- 3: -.--Connected with prescale
decimal point position
Connected with decimal
point position of display value
Use counter and timer
in common
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
Func
Explanation
Setting range
Notice
0: COUN 1: TIME
(K)
Timer
4digit type
40102(0065)
03/06/16
Time range
(HOUR/MIN/SEC)
0: 0.001s to 9.999s
1: 0.01s to 99.99s
2: 0.1s to 999.9s
3: 1s to 9999s
4: 1s to 99m59s
0: 0.001s to 999.999s
1: 0.01s to 9999.99s
2: 0.1s to 99999.9s
3: 1s to 999999s
4: 0.01s to 99m59.99s
5: 0.1s to 999m59.9s
03/06/16
UP/Down mode
(U-D)
0: UP
40104(0067)
03/06/16
Output mode
(OUTM)
0: OND
1: ONd1
2: ONd2
40105(0068)
03/06/16
40106(0069)
03/06/16
40107(006A)
40108(006B)
40109(006C)
40110(006D)
03/06/16
03/06/16
03/06/16
03/06/16
(M)
Tacho/
Speed/ Pulse
meter
6digit type
40103(0066)
(L)
Panel
meter
5: 0.1m to 999.9m
6: 1m to 9999m
7: 1m to 99h59m
8: 1h to 9999h
(O)
Sensor
controller
7: INt1
8: INt2
9: OFD
10: NFD
11: NFd1
12: INtG
unit: 10ms
unit: 10,ms
0:
0:
0:
0:
unit: ms
Use counter and timer in common
Use counter and timer in common
For the indicator
1: 20
1: REC
1: LOc1
1: HOLD
2: LOc2
2: ONtD
3: LOc3
(Q)
Stepper
motor&
Driver&Controller
1
CLR
lOFF
TOTAL
(P)
Switching
mode power
supply
1: DN
3: FLK
4: FLk1
5: FLk2
(N)
Display
unit
6: 1s to 9999m59s
7: 1m to 99999.9m
8: 1m to 999999m
9: 1s to 99h59m59s
10: 1m to 9999h59m
11: 0.1h to 99999.9h
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
J-33
CT Series
8) Function setting mode (Communication group)
No(Address)
Func
Explanation
Setting range
Notice
40151(0096)
40152(0097)
40153(0098)
40154(0099)
40155(009A)
40156(009B)
03/06/16
03/06/16
03/06/16
03/06/16
03/06/16
03/06/16
1 to 127
0: 24 1: 48 2: 96 3: 192 4: 384
0: NONE 1: EVEN 2: ODD
0: 1 1: 2
05 to 99
0: ENA 1: DISA
unit: 100bps
unit: ms
-
Exception processing
When communication error occurs, the highest bit of received function is set
to 1, then sends response command and transmits exception code.
Slave Address
Function+80H
Exception Code
1Byte
1Byte
1Byte
Error Check(CRC16)
Low
1Byte
High
1Byte
Query(Master)
Slave Address
Function
11H
01H
Starting Address
High
03H
No. of Points
Low
E8H
Error Check(CRC16)
High
00H
Low
01H
Low
##H
High
##H
Response(Slave)
Slave Address
Function + 80H
Exception Code
11H
81H
02H
Error Check(CRC16)
Low
High
##H
##H
00002(OUT2), 00003(OUT1), 00004(BA, 0), 10001 to 10005(Terminal input), 30101 to 30125(Product information),
31001 to 31013(Monitoring data)
00001(Reset starts), 00005(BATCH Reset starts), 40001 to 40006(Setting value saving group),
40051 to 40066(Counter setting group), 40101 to 40110(Timer setting group),
40151 to 40156(Communication setting group)
Read of communication
Communication write
J-34
Programmable Counter/Timer
Proper usage
(A)
Photo
electric
sensor
ON
OFF
100
(B)
Fiber
optic
sensor
500
(C)
Door/Area
sensor
Power voltage rises for 100ms after power on and falls for
500ms after power off. Therefore be sure to apply input
signal after 100ms and power turns on again after 500ms
when power turns off.
Be sure to use insulated and resistive voltage /current or
Class2 supply power device to input 24VAC/24-48VDC
power supply model.
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
When test dielectric voltage and insulation resistance of the control panel with this
unit installed.
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
Installation environment
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
J-35