Вы находитесь на странице: 1из 2

Phocus.

hr

zone A

Remote leak detection via AMR radio system

16dB

zone A

0dB

18dB

18 dB

15dB
20dB
B

Phocus.hr is a variant of the


Primayer Phocus range of noise
logger. It transmits data via
the AMR radio network of
HOMERIDER SYSTEMS. It is
designed to detect and localise
leaks in water distribution
networks under pressure.
Phocus.hr is permanently
installed on the network and
automatically determines the
presence of leaks.

14dB

zone D

3
9 dB
39dB

1
12dB
23dB
23
dB
B
18dB

12dB

21dB
B

8dB

zone D

19dB

22 dB
B

20dB
33dB
3 dB
B
18dB
1
8 dB 3
22dB
19dB
1
9 dB
18dB
1
8 dB
B

20dB
2
20d
0d
dB
B
21
2
1 dB
B
33 dB
33dB
B

23dB

20 dB
20dB
d

20 dB
11dB
11

22dB

17
1
7d
dB

16 dB
20 dB

47dB
B

21dB

Repeaters

19dB
B

15
5 dB
dB

23
dB
23dB

22dB

20dB
Loggers

16
1
6d
18 dB

30 dB
B
23dB
23
3 dB
B

23dB

12
2d
dB

29dB
B

19dB
1
9 dB
dB

26
26

20 dB

23
3dB
23
dB
17dB
1

19dB
1
19
9

11dB

21dB
19 dB
B

13dB
dB
B
18dB

12dB

15dB
16dB
1

18dB
B

3d
3dB
23dB

15dB

17dB

9dB
9d
dB
d
B
12 dB

Features

Operation

Transmission of daily information


Three different sample periods overnight

Phocus.hr is an intelligent noise logger which detects


the noise generated by a water leak. The logger
samples the pipeline noise at one second intervals
during each of three periods during the night.
(Night-time is when the background acoustic noise
is lowest).

separate genuine water use from leakage to


reduce false alarms

Uses Phocus noise algorithm for better


detection of leaks

Significantly reduced operating costs as no


drive-by required

Integrates with the AMR radio network

HOMERIDER SYSTEMS to reduce system


costs

Interfaced with the Veolia software LERNE


for optimum use of data

Phocus.hr makes a statistical analysis during each


of the three periods to determine the Leakage
Confidence Factor (LCF) or leak alarm status.
The logger transmits a daily radio message.
The message includes the LCF and the level of the
lowest measured noise (called the Critical Noise
Value). This value is important because it determines
the proximity of the leak from the Phocus.hr logger.

technology for network management and leakage control

Primayer

Concentrater

Logger set-up is via the OHR tool

Logger characteristics

Logger setup and data handling

Determines the presence and intensity of leak noise


Integral accelerometer with high sensitivity
Operation underground in most locations
Powered up to 5 years under typical operating

The Phocus.hr is configured through the OHR


software tool plus use of a stroboscopic touch. The
operator can define the minimum threshold level of
leak noise over which an alarm condition will occur.

conditions

Submersible to IP68

Tabular results display

The leakage status data is stored in LERNE

The daily transmitted data is integrated directly under


the host software platform LERNE. The user can
access all information including signature of leak noise,
Critical Noise Value and Leakage Confidence Factor.
Part Number
Phocus.hr noise logger
(including antenna)

AXG 972

Noise histogram

Primayer Limited
Primayer House, Parklands Business Park
Denmead, Hampshire PO7 6XP, United Kingdom
T +44 (0)2392 252228 F +44 (0)2392 252235
E sales@primayer.com
www.primayer.com

technology for network management and leakage control

Information in this document is subject to change without notice.