Вы находитесь на странице: 1из 6

Project Name

Area /Building
Doc. No.
Rev. No.

Date
Prep. By:
Check by:

Signature

CIB
PST

Calc. Report
Name: FOUL DRAINAGE STACK PIPE SIZING
References:
SI Nr.
1
2
3
4
6
7
8
General Data

Title/Description
BS 5255 Specification for thermoplastics waste pipe and fittings
BS 4660 Thermoplastics ancillary fittings of nominal sizes 110 and 160 for below ground gravity drainage and sewerage
BS 4514 Unplasticized PVC soil and ventilating pipes of 82.4 mm minimum mean outside diameter, and fittings and
accessories of 82.4 mm and of other sizes. Specification
BS 12056-2 :2000 Gravity drainage systems inside buildings. Sanitary pipework, layout and calculation
BS 8000-13:1989 Workmanship on building sites. Code of practice for above ground drainage and sanitary appliances
Uniform Plumbing Code 2009
Bangladesh National Building Code 2006 Part 8
Discharge System Type
Frequency Factor 'K'
Recommended degree of filling
Design Velocity
Slope
Coefficienet of roughness (Manning's Equation)
Material type

II
0.7
0.7

Ref. BSEN 12056-2:2000 Table 2


Ref. BSEN 12056-2:2000 Table 3
Ref. BSEN 12056-2:2000 Table 2
1.5 m/s
1%

0.013
UPVC /GRP

Grey Waste Water calc.


DU [l/s]

Qty /Unit of applicances per Area


Toilet 1
Pantry
Toilet 3
Toilet 4

APPLIANCE

Wash basin
Bidet
Shower without plug
Shower with plug
Bath
Kitchen sink
Dishwasher (household)
Washing machine (< 6 kg)
Washing machine (< 12 kg)
Floor gulley DN 50
Floor gulley DN 70
Floor gulley DN 100

0.30
0.30
0.40
0.50
0.60
1.20
0.90
0.90
1.20
0.90
0.90
1.20

1.00
3.00
1.00
1.00

5.00
1.00

1.00

Total DU [l/s] =
Flow rate 'Q

Black Water calc.


DU [l/s]

Qty /Unit of applicances per Area


Toilet 1
Pantry
Toilet 3
Toilet 4

APPLIANCE

Single urinal with cistern


Urinal with flushing valve
Slab urinal (per person)
WC with 4.0 l cistern
WC with 6.0 l cistern
WC with 7.5 l cistern
WC with 9.0 l cistern

0.50
0.30
0.20
1.80
1.80
1.80
2.00

3.00

3.00
Total DU [l/s] =
Flow rate 'Q

Toilet 5

Total
Qty
1.00
3.00
1.00
1.00
6.00
1.00
9.20
2.12

otal DU [l/s] =
ate 'Qww' [l/s] =

Toilet 5

otal DU [l/s] =
ate 'Qww' [l/s] =

Total
Qty
3.00
3.00
7.50
1.92

Table 2
I
DU [l/s]
APPLIANCE
Wash basin
Bidet
Shower without plug
Shower with plug
Single urinal with cistern
Urinal with flushing valve
Slab urinal (per person)
Bath
Kitchen sink
Dishwasher (household)
Washing machine (< 6 kg)
Washing machine (< 12 kg)
WC with 4.0 l cistern
WC with 6.0 l cistern
WC with 7.5 l cistern
WC with 9.0 l cistern
Floor gulley DN 50
Floor gulley DN 70
Floor gulley DN 100
Total DU [l/s] =
Flow rate per laundry 'Qww' [l/s] =

II
0.50
0.50
0.50
0.60
0.80
0.80
0.50
0.20
0.80
0.80
0.80
0.80
1.50
2.00
2.00
2.50
0.80
1.50
2.00

III
0.70
0.30
0.30
0.40
0.50
0.50
0.30 0.20
0.60
0.60
0.60
0.60
1.20
1.80
1.80
1.80
2.00
0.90
0.90
1.20

Usage of appliances
Intermitlent use, e.g. dwelling, guesthouse, office
Frequent use, eg. Hospital , school , restaurant, hotel
Congested use, eg. In toilets /showers open to public
Special use, e.g. laboratory

1.00
0.30
0.30
0.40
1.30
0.40
0.20
1.30
1.30
0.20
0.60
1.20
1.70
1.80
2.00
-

IV
1.00
0.30
0.30
0.40
0.50
0.50
0.30
0.20
0.50
0.50
0.50
0.50
1.00
2.00
2.00
2.50
0.60
1.00
1.30

K
0.5
0.7
1
1.2

Вам также может понравиться