Duct Air Quality Sensor
Description
Features
The duct air quality sensor is designed to measure the total air
quality. The semiconductor based element can detect a wide
range of gases and low concentrations of impurities and is ideal
for the control of ventilation rates in respect of occupancy and
contamination levels. The sensor, when used in the control of
ventilation rates, offers energy savings without compromising
the air quality.
Physical
90 mm (1.77)
45 mm
(1.77)
12 mm (0.47)
190 mm (7.48)
57 mm (2.74)
AQ/D
Trend Control Systems
Horsham, UK
105 mm (4.16)
97 mm (3.82)
85 mm (3.35) centres
AQ/D
Data Sheet
FUNCTIONALITY
The sensor is highly sensitive to gases given off from Volatile Organic Compounds (VOCs) as well as high levels of CO, CO2, and
high humidity. The sensor output is 0 to 10 Vdc and increases with the degree of contamination.
The air quality sensor is factory calibrated to provide 1 V output in clean uncontaminated conditions.
status LED
24V 0V OP
Delay Potentiometer
LD1 VR1
VR2
ADJUST DELAY
-
Status LED
Re-Calibration
1.
2.
3.
4.
5.
6.
Data Sheet
AQ/D
INSTALLATION
Due to the sensors sensitivity to numerous gases, the sensor cannot be rated in ppm across its output range so it is important at
the commissioning stage that the setting up is carried out in clean uncontaminated air.
The installation involves:
choose an accessible location for the sensor where there is good air movement but is not subject to high air velocity
drill 2 pilot holes at 85 mm centres in duct side to take No.6 20 mm self tapping screws (see template)
15 mm
2 pilot holes
42.5 mm
42.5 mm
CONNECTIONS
Run Cal
24V 0V OP
LD1 VR1
VR2
ADJUST DELAY
-
24V 0V OP
IQ1 or IQ2
IQ analogue input channel linked
for voltage (V)
24V (AUX)
C (0V)
IN
24V 0V OP
IQ3
0 (0V)
N (in)
24V
AQ/D
Data Sheet
PRODUCT CODE
AQ/D
DISPOSAL
WEEE Directive :
At the end of their useful life the packaging and
product should be disposed of using a suitable
recycling centre.
Do not dispose of with normal household waste.
Do not burn.
SPECIFICATION
Electrical
Output
Consumption
Power Supply
Sensing Element
Accuracy
Hysteresis
Sensitivity
Environmental
Operating limits
:0 to 10 Vdc
(0 V = good quality, 10 V = bad quality)
:96 mA maximum
:15 to 32 V (ac/dc)
:Tin dioxide semiconductor element
enclosed in flame proof stainless steel
housing.
:International standards to be agreed.
:Negligible
:Dependent on gas mix
:Designed for controlled environments
(e.g. return air) 18 to 24 C (64 to 75 F),
65 %RH 5%.
Mechanical
Input type
0 (volts)
Exponent
Dimensions
Duct tube
:190 mm long x 12 mm diameter
Fixing centres :85 mm
Head
:57 mm deep x 105 mm diameter (max.)
Cable entry :M20
Enclosure material
:Flame retardant (V0) ABS.
Connectors
:Single part for 1.0 mm (18 to 20 AWG)
Weight
:170 gm (6 ozs)
Protection
:IP67
Upper
100
0
Lower
Points
Ix
Ox
10
100
Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Srl, Ecublens, Route
du Bois 37,Switzerland by its Authorized Representative, Trend Control Systems Limited.
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content
hereof without obligation to notify any person of such revisions or changes.