PROJECT
Date
General Note: There are instances where the design class choices indicated below would require that an
exception be taken to certain requirements of DEP 31.21.70.31-Gen. Such exceptions may be included in
a project specific DEP or otherwise documented during project execution. The user should refer to the DEP
31.21.70.31 Informative for additional information a guidance on design class choices. In no cases should
design class choices supersede or otherwise modify SHALL [PS] process safety requirements as indicated
in DEP 31.21.70.31-Gen.
Capacity
Design
Item
Design Class
Class 2
Class 3
Exchanger SizingFouling
Consideration should be
given to using lower
tubeside fouling
resistances or design
margins than prescribed
by DEP 20.21.00.31. for
most services.
Tubeside fouling
resistances or design
margins should be applied
in accordance with DEP
20.21.00.31.
Consideration may be
given to using lower
resistances/margins for
select non-critical services.
Tubeside fouling
resistances or design
margins should be applied
in accordance with DEP
20.21.00.31.
Class 1
Note: Affect of fouling resistance and/or margin is related to impact on potential unit run
length and/or capacity utilization; not rate of fouling.
Electric Motor
Sizing
Page 1 of 7
ECCN EAR99
Design Class Detail
Heat Exchangers / Air Coolers
PROJECT
Date
Capacity Utilization
Design
Item
Design Class
Class 1
Class 2
Class 3
Services where fouling or
corrosion may be an issue
shall have a minimum of
two bundles. Isolation
valves shall also be
provided for each bundle
when fouling is expected
to occur.
Number of
Bundles
Number of Fans
One fan/bay is
acceptable. Note:
minimum fan coverage
and minimum plenum
depth requirements shall
still apply.
Fin Density
Number of
Adjustable
Frequency Drive
Controllers
When adjustable
frequency drive
controllers are provided
for process control, one
controller per service is
acceptable.
Fans, actuators, motors,
and belt/gear drive
transmission systems
may be considered for
design for less than four
(4) years of continuous
operation.
Fan, Actuator,
Belt/Gear, and
Motor Reliability
Page 2 of 7
ECCN EAR99
Design Class Detail
Heat Exchangers / Air Coolers
PROJECT
Date
Consideration may be
given to the use of Vbelts when allowed by
and compliant with ISO
13706.
Structural Design
Basis for Vibration
Minimization
Structure may be
Structure shall be designed in accordance with DEP
designed per base ISO
31.21.70.31 regardless of provisions for vibration
13706 loads with
detection.
provision of vibration
detection and monitoring
equipment.
Shop Run-In
Testing
Consideration may be
given to reducing the
number of bays to be
shop run-in tested to
of that required by DEP
31.21.70.31 This may
be further modified with
consideration of service
criticality.
Page 3 of 7
ECCN EAR99
Design Class Detail
Heat Exchangers / Air Coolers
PROJECT
Date
Clear Platform
Widths
Design Class
Class 1
Class 2
Class 3
Louvers shall be used if Adjustable frequency drives shall be used if air flow
air flow control is
control is required.
required.
Note: This selection is not applicable to exchangers for which process control is
provided either by on/off motor control and/or the use of two-speed motors.
The need for machinery Machinery and header
Machinery and header
or header platforms or
platforms and walkways
platforms and walkways
walkways shall be
shall be provided for all
shall be provided for all
considered on a project- coolers.
coolers.
by-project basis.
Full access maintenance
Full access maintenance
Full access maintenance platforms should be
platforms should be
platforms should not be
considered.
provided.
provided.
Platforms shall be
Platforms and walkways shall be provided with a clear
provided with a clear
width of 915 mm (3 ft) in accordance with DEP
width of 0.75 m (30
31.21.70.31.
inch) per ISO 13706.
Walkway and
Platform Access
for Elevated Units
Walkway and
Platform Access
for Grade Mounted
Units
Consideration may be
given to providing
rolling ladder access to
maintenance and header
platforms and walkways,
with the agreement of
the project HSE
specialist.
Ladder access to
maintenance and header
platforms and walkways
shall be in accordance with
DEP 31.21.70.31.
Tubes
Page 4 of 7
ECCN EAR99
Design Class Detail
Heat Exchangers / Air Coolers
PROJECT
Date
Minimum Bolt
Diameter for
Through Bolted
Construction
Minimum nominal
diameter shall be 16 mm
(5/8 in).
Use of Threaded
Connections
Threaded connections
may be considered for
connections less than
DN 40 (NPS 1 ) size.
Use of Slip-On
Nozzle Flange
Connections
Multi-Purpose
Header Box
Connections
Multi-purpose header
box connections should
not be provided. Note:
High and low points
must still be provided
with vent and drain
connections when not
otherwise vented or
drained though nozzles.
Oil-mist lubrication or
automatic greasing
systems should not be
applied.
Page 5 of 7
ECCN EAR99
Design Class Detail
Heat Exchangers / Air Coolers
PROJECT
Date
Motor Design
Compatibility for
Variable Speed
(Frequency)
Operation
Air Plenum
Thickness
Consideration may be
given to allow the use of
steel sheet materials in
thicknesses compliant
with ISO 13706.
Fan Deck
Thickness
Consideration may be
given to allow the use of
fan deck materials in
thicknesses compliant
with ISO 13706.
Page 6 of 7
ECCN EAR99
Design Class Detail
Heat Exchangers / Air Coolers
PROJECT
Date
Energy Efficiency
Design
Item
Air Cooled
Exchanger
Design
Optimization
Design Class
Class 1
Air cooled exchangers
should be designed and
selected basis lowest
initial capital cost
considerations only.
Class 2
Air cooled exchangers
should be designed and
selected with
consideration of both
initial capital cost and
energy efficiency,
considering a 3 year
simple payout on energy
usage.
Note: Specific services may be
exempted from this consideration if
there are over-riding project design
considerations, e.g. minimum plot
space.
Variable Speed
(Frequency)
Operation for
Energy
Conservation
Class 3
Air cooled exchangers
should be designed and
selected with
consideration of both
initial capital cost and
energy efficiency,
considering an NPV > 0
on energy usage.
Note: Specific services may be
exempted from this consideration if
there are over-riding project design
considerations, e.g. minimum plot
space.
services).