Вы находитесь на странице: 1из 4

Por JORGE LUIS FARHA fecha 12:08 , 04/11/2015

Nr.: 199303/2014

Curves

Date: 04-NOV-2014

PERFORMANCE CURVES RELATED TO SPEED

9.0

2.00

8.0
A

1.75

7.0

1.50
A - Torque related to full load torque

C - Torque related to full load torque at 0.80 Vn

2.25

6.0

1.25

5.0
D
C

1.00

4.0

0.75

3.0

0.50

2.0

0.25
0.00

1.0

E
0

10

20

30
40
50
60
70
Percent of synchronous speed

Customer
Product code
Product line

:
:
: Special Motor

Output
Frame
Rated speed
Frequency
Rated voltage
Insulation class
Rated current
Il/In

:
:
:
:
:
:
:
:

132 kW
355M/L
2982 rpm
50 Hz
2300 V
F
39.6 A
6.0

D- Current related to full load current at 0.80 Vn

10.0

B - Current related to full load current

E - Load torque related to full load torque

Three-phase Induction Motor - Squirrel Cage


2.50

80

Duty cycle
Service factor
Design
Enclosure
Locked rotor torque
Pull up torque
Breakdown torque

90

100

:
:
:
:
:
:
:

0.0

S1
1.00
N
IP55 (TEFC)
110 %
95 %
230 %

Notes:
TAG. NO: A113 JA
Load data:
Power: 109kW
Inertia (Pump + Coupling): 0.547kgm2
Starting time (Un / 80%Un): 5 / 14 s
This is an updated revision. The previous one must be disregarded.The figures given herewith are regarded as estimated values
based on calculation and applied to sinusoidal power supplied motors, within permissible tolerances under IEC 60034-1.

Performed by
aalves

Checked
premelgado

Revision
Nr.: 3
Date: 27-OCT-2015

Approved
Por JORGE LUIS FARHA fecha 12:08 , 04/11/2015

Nr.: 199303/2014

Curves

Date: 04-NOV-2014

PERFORMANCE UNDER LOAD


Three-phase Induction Motor - Squirrel Cage
C

1.0

0.0

A
1.0

90

0.9

80

0.8

70

0.7

3.0

60

0.6

4.0

50

0.5

5.0

40

0.4

2.0

B - Power factor

A - Efficiency (%)

60
40
D

10

20

30

40

20

50

60

70

80

90

D - Current at 2300V (A)

80

C - Slip (%)

100

0
100 110 120 130

Percent of rated output


Customer
Product code
Product line

:
:
: Special Motor

Output
Frame
Rated speed
Frequency
Rated voltage
Insulation class
Rated current
Il/In

:
:
:
:
:
:
:
:

132 kW
355M/L
2982 rpm
50 Hz
2300 V
F
39.6 A
6.0

Duty cycle
Service factor
Design
Enclosure
Locked rotor torque
Pull up torque
Breakdown torque

:
:
:
:
:
:
:

S1
1.00
N
IP55 (TEFC)
110 %
95 %
230 %

Notes:
TAG. NO: A113 JA
Load data:
Power: 109kW
Inertia (Pump + Coupling): 0.547kgm2
Starting time (Un / 80%Un): 5 / 14 s
This is an updated revision. The previous one must be disregarded.The figures given herewith are regarded as estimated values
based on calculation and applied to sinusoidal power supplied motors, within permissible tolerances under IEC 60034-1.

Performed by
aalves

Checked
premelgado

Revision
Nr.: 3
Date: 27-OCT-2015

Approved
Por JORGE LUIS FARHA fecha 12:08 , 04/11/2015

Nr.: 199303/2014

Curves

Date: 04-NOV-2014

THERMAL CAPACITY IN OVERLOAD


Three-phase Induction Motor - Squirrel Cage
10000

Time (s)

1000

100

10
A - Overload

B - Locked rotor (hot)

C - Locked rotor (cold)

1
1.0

1.5

2.0

2.5

Customer
Product code
Product line

:
:
: Special Motor

Output
Frame
Rated speed
Frequency
Rated voltage
Insulation class
Rated current
Il/In

:
:
:
:
:
:
:
:

132 kW
355M/L
2982 rpm
50 Hz
2300 V
F
39.6 A
6.0

3.0

3.5
I/In

4.0

4.5

Duty cycle
Service factor
Design
Enclosure
Locked rotor torque
Pull up torque
Breakdown torque

5.0

5.5

:
:
:
:
:
:
:

6.0

S1
1.00
N
IP55 (TEFC)
110 %
95 %
230 %

Notes:
TAG. NO: A113 JA
Load data:
Power: 109kW
Inertia (Pump + Coupling): 0.547kgm2
Starting time (Un / 80%Un): 5 / 14 s
This is an updated revision. The previous one must be disregarded.The figures given herewith are regarded as estimated values
based on calculation and applied to sinusoidal power supplied motors, within permissible tolerances under IEC 60034-1.

Performed by
aalves

Checked
premelgado

Revision
Nr.: 3
Date: 27-OCT-2015

Approved
Por JORGE LUIS FARHA fecha 12:08 , 04/11/2015