Академический Документы
Профессиональный Документы
Культура Документы
Page 1/10
Version number 18
Revision: 01.03.2016
Article number:
700 Pine, 702 Larch, 703 Mahogany, 706 Oak, 707 Walnut, 708 Teak, 710 Stone Pine,
712 Ebony, 727 Rosewood, 728 Red Cedar, 729 Fir Green, 731 Oregon Pine, 732
Light Oak, 900 White, 903 Basalt Grey, 905 Patina, 906 Pearl Grey, 907 Quartz Grey
42.0.3
Page 2/10
Version number 18
Revision: 01.03.2016
Additional information:
Dangerous components:
CAS: 64742-48-9
aliphatic hydrocarbons, C10-C13
EC number: 918-481-9
Asp. Tox. 1, H304
~
d
Index number: 649-327-00-6
Reg.nr.: 01-2119457273-39
25-50%
CAS: 34590-94-8
(2-methoxymethylethoxy)propanol
EINECS: 252-104-2
substance with a Community workplace exposure limit
Reg.nr.: 01-2119450011-60
3-<10%
CAS: 60207-90-1
propiconazole
<1%
EINECS: 262-104-4
Aquatic Acute 1, H400; Aquatic Chronic 1, H410; d
~
d
Acute Tox. 4, H302; Skin
~
Index number: 613-205-00-0 Sens. 1, H317
Additional information:
For the wording of the listed hazard phrases refer to section 16.
42.0.3
Page 3/10
Version number 18
Revision: 01.03.2016
Disziness
4.3 Indication of any immediate
medical attention and special
treatment needed
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant
foam.
Water with full jet
Formation of toxic gases is possible during heating or in case of fire.
Mouth respiratory protective device.
Cool endangered receptacles with water spray.
Dispose of fire debris and contaminated fire fighting water in accordance with official
regulations.
42.0.3
Page 4/10
Version number 18
Revision: 01.03.2016
Additional information:
8.2 Exposure controls
Personal protective equipment:
General protective and hygienic
measures:
Respiratory protection:
42.0.3
Page 5/10
Version number 18
Revision: 01.03.2016
The glove material has to be impermeable and resistant to the product/ the substance/
Protection of hands:
the preparation.
Selection of the glove material on consideration of the penetration times, rates of
diffusion and the degradation
Nitrile rubber, NBR
Material of gloves
Penetration time of glove material The exact break trough time has to be found out by the manufacturer of the protective
gloves and has to be observed.
For the permanent contact gloves
made of the following materials
Nitrile rubber, NBR
are suitable:
Recommended thickness of the material: 0.4 mm
For the mixture of chemicals mentioned below the penetration time has to be at least
480 minutes (Permeation according to EN 374 Part 3: Level 6).
As protection from splashes
gloves made of the following
Nitrile rubber, NBR
materials are suitable:
Goggles recommended during refilling
Eye protection:
Protective work clothing
Body protection:
*
Undetermined.
> 180 C
Flash point:
Ignition temperature:
240 C
Self-igniting:
Danger of explosion:
Explosion limits:
Lower:
Upper:
0.6 Vol %
7.0 Vol %
Density at 20 C:
42.0.3
Page 6/10
Version number 18
Revision: 01.03.2016
Solvent content:
VOC (EC)
9.2 Other information
LD50
Dermal
LD50
Inhalative LC50 / 4h
42.0.3
Page 7/10
Version number 18
Revision: 01.03.2016
34590-94-8 (2-methoxymethylethoxy)propanol
Oral
LD50
Dermal
LD50
Inhalative LC50 / 4h
LD50
Dermal
LD50
Inhalative LC50 / 4h
At long or repeated contact with skin it may cause dermatitis due to the degreasing
effect of the solvent.
not tested
Serious eye damage/irritation
Respiratory or skin sensitisation Based on available data, the classification criteria are not met.
Contains propiconazole. May produce an allergic reaction.
Sensitisation
CMR effects (carcinogenity, mutagenicity and toxicity for reproduction)
Based on available data, the classification criteria are not met.
Germ cell mutagenicity
Based on available data, the classification criteria are not met.
Carcinogenicity
Based on available data, the classification criteria are not met.
Reproductive toxicity
Based on available data, the classification criteria are not met.
STOT-single exposure
Based on available data, the classification criteria are not met.
STOT-repeated exposure
Based on available data, the classification criteria are not met.
Aspiration hazard
EC50/ 72h
LC50 / 96h
LC50 / 96h
LC50 / 48h
42.0.3
Page 8/10
Version number 18
Revision: 01.03.2016
60207-90-1 propiconazole
EC50 / 48h
EC50/ 72h
LC50 / 96h
LC50 / 48h
Must not be disposed together with household garbage. Do not allow product to reach
sewage system.
Void
Void
(Contd. on page 9)
GB
42.0.3
Page 9/10
Version number 18
Revision: 01.03.2016
Void
Void
No
Not applicable.
UN "Model Regulation":
42.0.3
Page 10/10
Version number 18
Revision: 01.03.2016