Академический Документы
Профессиональный Документы
Культура Документы
ABSTRACT
Power failure is a common problem. It is hampering
the production of industries, patient care services of
hospitals, regular functioning of schools, colleges and
offices. It can be overcome by using a backup power
supply such as a generator. But it is not cost effective
and also time consuming as certain time is required to
switch on the generator manually. It is often noticed
that power interruption in distribution system is about
70% for single phase faults while other two phases
are in normal condition. Thus, in any commercial or
domestic power supply system where 3 phases is
available, an automatic phase selector system is
required for uninterrupted power to critical loads in
the event of power failure in any phase. There is no
requirement of backup power supply in that case.
1. INTRODUCTION
Most companies, industrial, commercial and even
domestic are dependent on public power supply
which has erratic supply such as phase failure, phase
imbalances or total power failure due to one or more
technical problem in power generation, transmission
or distribution. If all the three phases are available,
there is need for automation of phase change during
Gear Motor
Battery
Op Amp
12 V
12 V
IC 741
4.
CIRCUIT DIAGRAM:
SELECTOR
CIRCUIT
3. LIST OF EQUIPMENTS
3.1 Electrical & Electronics Equipments:
Equipments
Rating
Transformer
Capacitor
Resister
Electromagnetic Relay
5. OPERATION:
Automatic phase selector is applicable for a single
6.
R
RESULT:
Y
OpAmp
Selected
Phase
Phase
Phase
Output
Active
Active
Active
Active
Active
Absent
Absent
Absent
Active
Active
Absent
Active
Absent
Active
Absent
1
1
1
1
Phase
Any of
three
( say Y)
B
R
Y
None
7. CONCLUSIONS:
According to the result it is seen that we get the
desired output from the auto phase selector.
Automatically it is selecting the active phase when
the connected phase is absent. The only problem is
when all the three phases are not active, the motor
continues to rotate and will not stop until we switch
off the 12V supply of the motor manually. This
problem can be overcome by implementing a timer
circuit which will automatically switch off the
power supply of the motor after a certain time. But
our main objective is to select an active phase
automatically to save the time and without
hampering the work. This objective is satisfied
successfully here.
8. REFERENCES:
[1] Ashish Kumar Gupta, Chandan Singh,
Gurpreet Singh, Arun Kumar, Automatic Cost
Effective Phase Selector International Journal of
Advanced Research in Electrical, Electronics and
Instrumentation Engineering, Vol. 4, Issue 5, May
2015
[2] Oduobuk, E. J., Ettah, E. B., Ekpenyong, E. E.,
Design and Implementation of Automatic Three
Phase Changer Using LM324 Quad Integrated