I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\_CS.

DWG 10-13-14 10:53 AM PRINTED BY: JOESLAGLE

ABV
AC
ACT
ADJ
AFF
ALT
ALUM
ARA
BD
BLDG
BLK
BOT
B.O.
BS
C/C
CAB
CJ
CL
CLG
CLR
CMU
CONC
COL
CONT
CPT
CT
CTR
DET
DIM
DN
DR
DWG(S)
EA
EF
EJ
ELEC
ELEV
EQ
EQUIP
EWC
EXP
EXST
EXT
FD
FE
FEC
FF
FIN
FLR
FT
GA
GL
GWB
GYP
HT or HGT
HCWD
HDWE
HM
HMBL

ABOVE
ACOUSTIC
ACOUSTICAL TILE CEILING
ADJUSTABLE
ABOVE FINISH FLOOR
ALTERNATE
ALUMINUM
AREA OF RESCUE ASSISTANCE
BOARD
BUILDING
BLOCK
BOTTOM
BOTTOM OF
BOTH SIDES
CENTER TO CENTER
CABINET
CONTROL JOINT
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
CONCRETE
COLUMN
CONTINUOUS
CARPET
CERAMIC TILE
COUNTER
DETAIL
DIMENSION
DOWN
DOOR
DRAWING(S)
EACH
EXHAUST FAN
EXPANSION JOINT
ELECTRICAL
ELEVATION
EQUAL
EQUIPMENT
ELECTRIC WATER COOLER
EXPANSION
EXISTING
EXTERIOR
FLOOR DRAIN
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISHED FLOOR
FINISH
FLOOR
FOOT or FEET
GAUGE
GLASS
GYPSUM WALL BOARD
GYPSUM
HEIGHT
HOLLOW CORE WOOD DOOR
HARDWARE
HOLLOW METAL
HOLLOW METAL BORROWED LITE

HORIZ
ID
INSUL
LAM
MATL
MAX
MECH
MFR
MIN
MO
MT
MTL
NIC
NO
NOM
NTS
OC
OD
OPP
PMF
PLAM
PRT
PT
PTD
RB
REINF
REQ'D
RM
RO
RV
SCH
SCWD
SECT
SF
SIM
SPEC
SS
STD
STND
STL
STOR
STRUCT
T&G
TEMP
THK
TOM
TOS
TYP
UNO
VAR
VB
VCT
VCWD
VERT
VIF
VPAB
w/
WD
WWF

HORIZONTAL
INSIDE DIAMETER
INSULATION
LAMINATED
MATERIAL
MAXIMUM
MECHANICAL
MANUFACTURER
MINIMUM
MASONRY OPENING
METAL THRESHOLD
METAL
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OPPOSITE
PRE MOLDED FILLER
PLASTIC LAMINATE
PRESSURE TREATED
PORCELAIN TILE
PAINTED
RUBBER BASE
REINFORCING
REQUIRED
ROOM
ROUGH OPENING
ROOF VENT
SCHEDULE
SOLID CORE WOOD DOOR
SECTION
SQUARE FOOT
SIMILAR
SPECIFICATION
STAINLESS STEEL
STANDARD
STAINED
STEEL
STORAGE
STRUCTURAL
TONGUE & GROOVE
TEMPERED or TEMPORARY
THICK(NESS)
TOP OF MASONRY
TOP OF STEEL
TYPICAL
UNLESS NOTED OTHERWISE
VARIES
VAPOR BARRIER or VINYL BASE
VINYL COMPOSITION TILE
VINYL CLAD WOOD
VERTICAL
VERIFY IN FIELD
VAPOR PERMEABLE AIR BARRIER
WITH
WOOD
WELDED WIRE FABRIC

STRUCTURAL

SYMBOLS
A
A301

CIVIL / LAND DEVELOPMENT

DRAWING INDEX
A
A301

2
A303

BUILDING SECTION

COVER SHEET

MECHANICAL / ELECTRICAL

DRAWING NOTES
ELECTRICAL
NOTE: SEE NARRATIVE IN OUTLINE SPECIFICATION

REFERENCE DWG. NO.

CIVIL / SITE

WALL SECTION

1 OF 1
1 OF 1

EXISTING CONDITIONS / CONCEPT OPTION A1


EXISTING CONDITIONS / CONCEPT OPTION A2

REFERENCE DWG. NO.


DETAIL OR ENLARGEMENT

C
A501

REFERENCE DWG. NO.


ELEVATION OR SECTION

F
A201

REFERENCE DWG. NO.


FIN. FLR.
+1429'-0"

ELEVATION INDICATOR
ROOM NAME
ROOM NO.

ARCHITECTURAL
CS
A100
A101
A102
A103
A104
A201
A202
A203
A301
A302
A601

COVER SHEET
EGRESS FLOOR PLAN / CODE COMPLIANCE
COMPOSITE FLOOR PLAN & MEZZANINE PLAN
ROOF PLAN
OFFICE PLAN ENLARGEMENT
WAREHOUSE PLAN ENLARGEMENTS
EXTERIOR ELEVATIONS - SIDING AND MASONRY
EXTERIOR ELEVATIONS - ALL MASONRY
EXTERIOR ELEVATIONS - PRECAST
BUILDING SECTION
EXTERIOR WALL SECTION & DETAILS
SCHEDULES, NOTES

UL HOURLY RATING

STRUCTURAL

U905-1

UL RATING DESIGNATION

MATERIALS
WOOD BLOCKING
FINISHED LUMBER
CMU
BRICK VENEER
STEEL

S001
S002
S101
S102
S103
S201
S202
S203
S204
S301
S302
S303
S304
S401
S401

GENERAL NOTES
TYPICAL SCHEDULES
FOUNDATION PLAN
MEZZANINE FRAMING
ROOF FRAMING PLAN
FOUNDATION DETAILS
FOUNDATION DETAILS
WALL FOOTING SECTIONS
FOUNDATION SECTIONS
FRAMING DETAILS
FRAMING DETAILS
FRAMING SECTIONS
WALL DETAILS
LATERAL BRACING ELEVATIONS
LATERAL BRACING DETAILS

EARTH
CONCRETE

MECHANICAL / PLUMBING
NOTE: SEE NARRATIVE IN OUTLINE SPECIFICATION

FIRE PROTECTION
NOTE: SEE NARRATIVE IN OUTLINE SPECIFICATION

LOCATION PLAN
NO SCALE

14-665 | 17 OCTOBER 2014

ARCHITECTURAL ABBREVIATIONS

ARCHITECT

TONO ARCHITECTS, LLC

DESIGN / BUILD CONTRACTOR

2 PERSONS ACTUAL

33" CLR = 110 PERSONS

2 PERSONS ACTUAL

33" CLR = 110 PERSONS

2 PERSONS ACTUAL

33" CLR = 110 PERSONS

2 PERSONS ACTUAL

33" CLR = 110 PERSONS

33" CLR = 110 PERSONS


2 PERSONS ACTUAL

162'

52'

77'

171'

170'

86'

100'

77'

110'

100'

100'

2 PERSONS ACTUAL

33" CLR = 110 PERSONS

2 PERSONS ACTUAL

33" CLR = 110 PERSONS

2 PERSONS ACTUAL

100 SF / PERSON
10 OCCUPANTS

33" CLR = 110 PERSONS

7 PERSONS ACTUAL

33" CLR = 110 PERSONS

33" CLR = 110 PERSONS

5 PERSONS ACTUAL

CODE COMPLIANCE INFORMATION


PROPOSED WAREHOUSE

EGRESS PLAN
SCALE: 1/16"=1'-0"

APPLICABLE CODES:
IBC 2009

5 PERSONS ACTUAL

33" CLR = 110 PERSONS

UNIFORM CONSTRUCTION CODE, 2009 INTERNATIONAL BUILDING CODE, 2009 INTERNATIONAL MECHANICAL CODE, 2009 INTERNATIONAL PLUMBING CODE, 2009 ICC ELECTRICAL CODE,
2009 INTERNATIONAL ENERGY CONSERVATION CODE AND ICC/ANSI A117.1-2014.

CHAPTER 3

USE AND OCCUPANCY CLASSIFICATION:


OCCUPANCY OF STRUCTURE:

CHAPTER 6

S-1 (WAREHOUSE)

TYPES OF CONSTRUCTION:
CONSTRUCTION CLASSIFICATION:
TABLE 503

TABLE 1004.1.1

TYPE - IIB

HEIGHT:

ALLOWED: 3 STORIES / 75'-0"

AREA:

S-1 (WAREHOUSE) - ALLOWED: 83,125

PROVIDED: 1 STORY / 38'-0"

OCCUPANCY LOAD:

100 PERSONS (CALCULATED) / 28 PERSONS (ACTUAL)

PROVIDED: 51,937

CHHAPTER 7

250'

TRAVEL DISTANCE (FT.)

TACTILE EXIT SIGN

ILLUMINATED EXIT SIGN (SEE ELECTRICAL


DRAWINGS FOR EXACT QUANTITY & LOCATION)
33" CLR = 110 PERSONS
61 PERSONS ACTUAL

Aa = {17,500 + [17,500 x .75] + [17,500 x 3] } = 81,125 S.F.

CHAPTER 9

FIRE RESISTANCE RATING REQUIREMENTS FOR:

TYPE IIB

STRUCTURAL FRAME:

0-HOUR

BEARING WALLS EXTERIOR:

0-HOUR

BEARING WALLS INTERIOR:

0-HOUR

NON-BEARING WALLS EXTERIOR:

0-HOUR

NON-BEARING WALLS INTERIOR:

0-HOUR

FLOOR CONSTRUCTION:

0-HOUR

ROOF CONSTRUCTION:

0-HOUR

FIRE BARRIERS:
FIRE WALLS (706.1):

(TABLE 706.4)

NOT APPLICABLE

SHAFT ENCLOSURES (707.3.1):

(SECTION 708.4)

NOT APPLICABLE

EXIT ENCLOSURES (707.3.2):

(SECTION 1022.1)

NOT APPLICABLE

EXIT PASSAGEWAYS (707.3.3):

(SECTION 1023.3)

NOT APPLICABLE

HORIZONTAL EXITS (707.3.4):

(SECTION 1025.1)

NOT APPLICABLE

FIRE AREAS: (707.3.9)

(TABLE 707.3.9)

NOT APPLICABLE

CORRIDORS: (1018)

(TABLE 1018.1)

0-HOUR w/ SPRINKLERS

(SECTION 903)

REQUIRED (SECTION 903.2.9) (ESFR PROVIDED)

FIRE ALARM & DETECTION SYSTEMS:

(SECTION 907)

NOT REQUIRED

PORTABLE FIRE EXTINGUISHERS (SECTION 906):

TYPE 2A EXTINGUISHER FOR EVERY 6,000 SF (S-1 OCCUPANCY & DURING


CONSTRUCTION FOR BOTH S-1 AND B OCCUPANCIES).

FIRE PROTECTION:
AUTOMATIC SPRINKLER SYSTEMS:

IECC 2009
CHAPTER 5

COMMERCIAL ENERGY EFFICIENCY:


TABLE 502.2(1)

BUILDING ENVELOPE REQUIREMENTS:


ROOF:

EGRESS COMPONENT CAPACITY


OCCUPANTS TO EXIT

1 - HOUR FIRE BARRIER

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A100.DWG 10-13-14 10:56 AM PRINTED BY: JOESLAGLE

SECTION 506.1 GENERAL.


THE AREAS LIMITED BY TABLE 503 SHALL BE PERMITTED TO BE INCREASED DUE TO FRONTAGE (IF) AND AUTOMATIC SPRINKLER SYSTEM PROTECTION (IS) IN ACCORDANCE WITH THE FOLLOWING:
Aa = {At + [At x If] + [At x Is] } (EQUATION 5-1)
WHERE:
Aa
=
ALLOWABLE AREA PER STORY (SQUARE FEET).
At
=
TABULAR AREA PER STORY IN ACCORDANCE WITH TABLE 503 (SQUARE FEET).
f
=
AREA INCREASE FACTOR DUE TO FRONTAGE AS CALCULATED IN ACCORDANCE WITH SECTION 506.2.
s
=
AREA INCREASE FACTOR DUE TO SPRINKLER PROTECTION AS CALCULATED IN ACCORDANCE WITH SECTION 506.3.

IIB

NOTE:
1. SEE ELECTRICAL DRAWINGS FOR LOCATION OF
EMERGENCY LIGHTING & PULL STATIONS
2. EXTERIOR DOORS NOT PART OF THE EGRESS PATH
WILL RECEIVE SIGNAGE LABELED "NOT AN EXIT" AS
INDICATED ON DRAING A401.

SECTION 506.2 FRONTAGE INCREASE.


EVERY BUILDING SHALL ADJOIN OR HAVE ACCESS TO A PUBLIC WAY TO RECEIVE AN AREA INCREASE FOR FRONTAGE. WHERE A BUILDING HAS MORE THAN 25 PERCENT OF ITS PERIMETER ON A
PUBLIC WAY OR OPEN SPACE HAVING A MINIMUM WIDTH OF 20 FEET (6096 MM), THE FRONTAGE INCREASE SHALL BE DETERMINED IN ACCORDANCE WITH THE FOLLOWING:
f = [F / P 0.25] W / 30
(EQUATION 5-2)
WHERE:
f
=
AREA INCREASE DUE TO FRONTAGE.
F
=
BUILDING PERIMETER THAT FRONTS ON A PUBLIC WAY OR OPEN SPACE HAVING 20 FEET (6096 MM) OPEN MINIMUM WIDTH (FEET).
P
=
PERIMETER OF ENTIRE BUILDING (FEET).
W
=
WIDTH OF PUBLIC WAY OR OPEN SPACE (FEET) IN ACCORDANCE WITH SECTION 506.2.1.

f = [1050 / 1050 0.25] 30/30 = 75.00%


(75.00%)(17,500 S.F.) = 13,125 S.F.

WALLS, ABOVE GRADE:

CLIMATE ZONE 5
INSULATION ENTIRELY ABOVE DECK

R-20 (CONTINUOUS)

METAL BUILDINGS w/ THERMAL BLOCKS

R-13 + R-13

ATTIC AND OTHER

R-38

MASS

R-11.4 (CONTINUOUS)

METAL BUILDINGS

R-13 + R-5.6 (CONTINUOUS)

METAL FRAMED

R-13 + R-7.5 (CONTINUOUS)

WALLS, BELOW GRADE:

BELOW GRADE WALL

R-7.5 (CONTINUOUS)

FLOORS:

MASS

R-10 (CONTINUOUS)

SLAB-ON GRADE FLOORS:

UNHEATED SLAB

NO REQUIREMENT

HEATED SLAB

R-15 FOR 24 in. BELOW

30% PROGRESS DRAWING

NEW WAREHOUSE FOR:

LIFE SAFETY LEGEND

</= 10'-0" x < 30'-0"

TYPES OF CONSTRUCTION:

EGRESS PLAN / CODE COMPLIANCE

TABLE 601

FIRE SEPARATION DISTANCE:

257 SOUTH 9TH STREET COLUMBIA PA 17512

TABLE 602

KLEEN- RITE CORPORATION

FIRE RESISTANCE RATED CONSTRUCTION:

ACCESS GATES

ELEV EQUIP
202

STAIR
1

42" H. STEEL PIPE


RAILING TYP.

ELEV

ROOF HATCH
& LADDER

STAIR
2
MEZZANINE
201
42" H. STEEL PIPE
RAILING TYP.

SKYLIGHT (TYP)
FIN. FLR
350'-0"

FIN. FLR
352'-0"

42" H. STEEL PIPE


RAILING TYP.

STANDING SEAM METAL


DOCK CANOPY
301
A

MEZZANINE STOPS SHORT


OF EXTERIOR WALL TO
ALLOW VERTICAL LIFT
SECTIONAL DOOR
CLEARANCE.
SEE SECTION 1 & 2 ON
DRAWING A301

MEZZANINE LEVEL
SCALE: 1/16"=1'-0"

6,880 NET S.F.

A
301

GRADE
336.0'

GRADE
333'.0'

GRADE
329.0'

BRIDGE (TYP.)

GRADE
324.0'

FIN. FLR
333-0"

GRADE
336.0'

GRADE
323.0'

HIGH DENSITY RACK AREA

FLOOR
STORAGE
AREA

4'-0"

1'-0"
4'-0"

16'-6"

4'-0" 4'-0"

16'-6"

4'-6" 4'-0" 4'-0" 4'-6"

TYPICAL AISLE
TYPICAL RACK
NOTES:
FIRE PUMP ROOM TO HAVE
1 HR RATED CMU WALLS,
STEEL JOIST, METAL DECK
AND 4" CONCRETE CAP.
PROVIDE 125 LB LIVE LOAD ON
STORAGE CAP.

FIRE
PUMP RM
116
SKYLIGHTS (TYP)

SKYLIGHTS (TYP)

GRADE
322.0'

SWEEP
& DUMP
115
FIN. FLR
333-0"

DATA
CLOSET
113

DRIVER
REST RM
102

WOMEN
108

DRIVER
CHECK-IN
101

CLERKS'
AREA
112

GRADE
329.0'

GEN.

PIPE BOLLARDS
W/ RAIL

GRADE
323.0'

FIRST FLOOR PLAN


SCALE: 1/16"=1'-0"

50,643 NET S.F.

FIN. FLR
333-0"
PIPE BOLLARDS
(TYPICAL WHERE
SHOWN)

ELECTRICAL
110

OFFICE
111

GRADE
327.0'

GRADE
328.0'

PIPE BOLLARDS

MEN
109

OFFICE CORRIDOR
114

SHWR RM
118

WAREHOUSE
117

DOCK LEVELERS (TYP)

GRADE
329.08'

TRAN.

301
A

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A101.DWG 10-13-14 10:57 AM PRINTED BY: JOESLAGLE

BORDER OF CONCRETE APRON


(SEE CIVIL DRAWINGS)

30% PROGRESS DRAWING

COMPOSITE FIRST FLOOR & MEZZANINE PLAN

STAIR
2

ELEV
1

CONF RM
104
MECH / ELEC
103

BRIDGE (TYP.)

JAN
106

257 SOUTH 9TH STREET COLUMBIA PA 17512

KITCHENETTE STORAGE
STAIR
107
105
1

KLEEN- RITE CORPORATION

PIPE BOLLARDS
(TYPICAL WHERE
SHOWN)

NEW WAREHOUSE FOR:

GRADE
333.0'

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A102.DWG 10-13-14 10:58 AM PRINTED BY: JOESLAGLE

1
R O O F PLAN
SCALE: 1/16"=1'-0"

30% PROGRESS DRAWING

ROOF PLAN

257 SOUTH 9TH STREET COLUMBIA PA 17512

KLEEN- RITE CORPORATION

NEW WAREHOUSE FOR:

SLOPE 1/4" PER FOOT (TYPICAL)

SLOPE 1/4" PER FOOT (TYPICAL)

SLOPE 1/4" PER FOOT (TYPICAL)

SLOPE 1/4" PER FOOT (TYPICAL)

SLOPE 1/4" PER FOOT (TYPICAL)

SKYLIGHTS (TYP)
SKYLIGHTS (TYP)

ROOF HATCH

NOTE:
1. ALL DOWNSPOUTS TO CONNECT
TO UNDERGROUND STORM
WATER PIPING

STAIR
1

DW

JAN
106
6'-6" X 10'-0"

KITCHENETTE
107
8'-0" X 11'-6"

CONFERENCE ROOM
104

U.C. REF

11'-6" X 15'-4"

STORAGE
105

DATA CLOSET
113

6'-6" X 10'-0"

4'-0" X 7'-3"

ELEVATOR
1

WAREHOUSE
117

COAT ROD & SHELF

MECH. / ELEC.
103

OFFICE CORRIDOR
114

5'-6" X 8'-0"

5'-6" X 33'-0"

DRIVER
RESTROOM
102
6'-0" X 7'-3"

6'-0" X 10'-4"

6'-0" X 7'-3"

CLERKS' AREA
112

OFFICE
111

ELECTRICAL
110

11'-0" X 21'-0"

10'-6" X 12'-0"

6'-0" X 13'-6"

DRIVER
CHECK-IN
101

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A103.DWG 10-13-14 11:01 AM PRINTED BY: JOESLAGLE

GENERATOR

TRANSFORMER

PARTIAL ENLARGED OFFICE PLAN


SCALE: 1/4"=1'-0"

30% PROGRESS DRAWING

NEW WAREHOUSE FOR:

9'-0" X 13'-0"

ENLARGED OFFICE PLAN

COUNTER &
PASS-THRU

257 SOUTH 9TH STREET COLUMBIA PA 17512

6'-0" X 7'-3"

WOMEN
108

KLEEN- RITE CORPORATION

SHOWER RM
118

MEN
109

TOP OF PARAPET

FABRAL 24 GA.
CONCEALED
FASTENER "SELECT
SERIES" R-RO W/
INSULATED LINER
PANEL LP-14 OR
APPROVED EQUAL
SYSTEM.
8" CHAMFERED
GROUND FACE BAND
8" CHAMFERED
GROUND FACE BAND

FIN. FLR
333'-0"

WEST ELEVATION ALTERNATE MASONRY & VERTICAL METAL SIDING


SCALE: 1/16"=1'-0"

RWC CONDUCTOR W/
DOWNSPOUT (TYP)

ROOF LINE BEYOND

FABRAL 24 GA.
CONCEALED
FASTENER "SELECT
SERIES" R-RO W/
INSULATED LINER
PANEL LP-14 OR
APPROVED EQUAL
SYSTEM.
8" CHAMFERED
GROUND FACE BAND
8" CHAMFERED
GROUND FACE BAND

SPLIT FACE CMU


SPLIT FACE CMU

METAL STAIRS (TYP)

SOUTH ELEVATION ALTERNATE / MASONRY & VERTICAL METAL SIDING

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A201.DWG 10-13-14 11:04 AM PRINTED BY: JOESLAGLE

NEW WAREHOUSE FOR:

SCALE: 1/16"=1'-0"

30% PROGRESS DRAWING

KLEEN- RITE CORPORATION

POURED CONCRETE
FOUNDATION

257 SOUTH 9TH STREET COLUMBIA PA 17512

FIN. FLR
333'-0"

SOUTH & WEST EXTERIOR ELEVATIONS / MASONRY & METAL

HORIZONTAL BAND

PARAPET
BRICK CORBEL (TYP)

COMMERCIAL BRICK
4 X 12
8" CHAMFERED
GROUND FACE BAND

8" CHAMFERED
GROUND FACE BAND

FIN. FLR
333'-0"

SPLIT FACE BAND

WEST ELEVATION / ALL MASONRY

ROOF LINE BEYOND

COMMERCIAL BRICK
4 X 12

RWC CONDUCTOR W/
DOWNSPOUT (TYP)

BRICK CORBEL (TYP)

COMMERCIAL BRICK
4 X 12

FIN. FLR
333'-0"

POURED CONCRETE
FOUNDATION

SPLIT FACE CMU


SPLIT FACE CMU

METAL STAIRS (TYP)

SOUTH ELEVATION / ALL MASONRY

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A202.DWG 10-13-14 11:06 AM PRINTED BY: JOESLAGLE

NEW WAREHOUSE FOR:

SCALE: 1/16"=1'-0"

30% PROGRESS DRAWING

KLEEN- RITE CORPORATION

FIN. FLR
333'-0"

257 SOUTH 9TH STREET COLUMBIA PA 17512

8" CHAMFERED
GROUND FACE BAND

SOUTH & WEST EXT. ELEVATIONS / ALTERNATE ALL MASONRY

SCALE: 1/16"=1'-0"

LIGHT SANDBLASTED
PRECAST PANEL

PRECAST PANEL

MEDIUM
SANDBLASTED
PRECAST PANEL

LIGHT SANDBLASTED
PRECAST PANEL
FIN. FLR
333'-0"

POURED CONCRETE
FOUNDATION

WEST ELEVATION ALTERNATE OPTION # 2


SCALE: 1/16"=1'-0"

RWC CONDUCTOR W/
DOWNSPOUT (TYP)

PRECAST PANEL

MEDIUM
SANDBLASTED
PRECAST PANEL

LIGHT SANDBLASTED
PRECAST PANEL
FIN. FLR
333'-0"

METAL STAIRS (TYP)

SOUTH ELEVATION / PRECAST PANEL

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A203.DWG 10-13-14 11:07 AM PRINTED BY: JOESLAGLE

NEW WAREHOUSE FOR:

SCALE: 1/16"=1'-0"

30% PROGRESS DRAWING

257 SOUTH 9TH STREET COLUMBIA PA 17512

POURED CONCRETE
FOUNDATION

KLEEN- RITE CORPORATION

POURED CONCRETE
FOUNDATION

SOUTH & WEST EXT. ELEVATIONS / ALTERNATE PRECAST PANEL

LIGHT SANDBLASTED
PRECAST PANEL

1
A302
SIM

METAL COPING

7"

SKYLIGHT: PROVIDE SECURITY BAR


GRID, #4 BARS AT 6" O.C. WELDED
TO STRUCTURE SUPPORT FRAME

2'-5"

TYPICAL ROOF CONSTRUCTION :


60 MIL SINGLE PLY FULLY ADHERED EPDM
ROOF MEMBRANE ON 5" +/- OF RIGID INSULATION
R20 MIN. ON 1.5" METAL DECK & STEEL JOISTS.

SCUPPER (TYP.)
25'-0" O.C.
T.O.P.
364.25
T.O.S.
362.20'

4"
2'-8"

5'-0"

37'-4"

3'-0"

33'-4"

MEZZANINE LEVEL
350.00'

28'-0" MINIMUM CEILING CLEAR HEIGHT

31'-2 1/2"

11'-9"

HEAD BOX AND


DOWNSPOUT
25'-0" O.C. CONNECT
TO UNDER GROUND
STORM WATER
PIPING

12'-0"

14'-0"

17'-0"

B.O. CANOPY
345-00'

TYPICAL CONCRETE FLOOR SLAB CONSTRUCTION :


7" THICK CONC. SLAB, REINFORCED W /
FIBER MESH ON 4" COMPACTED STONE BASE AND FILL.
PROVIDE 4" THICK SLAB AT OFFICE AREA

FIN. FLOOR
333-00'
4'-0"

GRADE VARIES
SEE CIVIL DRAWINGS

GRADE
329-00'

PROPOSED BUILDING SECTION ALL MASONRY EXTERIOR


SCALE: 3/16"=1'-0"

1
302
SKYLIGHT: PROVIDE SECURITY BAR
GRID, #4 BARS AT 6" O.C. WELDED
TO STRUCTURE SUPPORT FRAME

METAL COPING
7"

2'-5"

TYPICAL ROOF CONSTRUCTION :


60 MIL SINGLE PLY FULLY ADHERED EPDM
ROOF MEMBRANE ON 5" +/- OF RIGID INSULATION
R20 MIN. ON 1.5" METAL DECK & STEEL JOISTS.

SCUPPER (TYP.)
25'-0" O.C.

T.O.P.
364.25
B.O.D.
362.20'

FIN. FLOOR
333-00'
4'-0"

GRADE VARIES
SEE CIVIL DRAWINGS

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A301.DWG 10-13-14 11:08 AM PRINTED BY: JOESLAGLE

GRADE
329-00'

PROPOSED BUILDING SECTION PARTIAL MASONRY & METAL SIDING


SCALE: 3/16"=1'-0"

30% PROGRESS DRAWING

PROPOSED BUILDING SECTION

TYPICAL CONCRETE FLOOR SLAB CONSTRUCTION :


7" THICK CONC. SLAB, REINFORCED W /
FIBER MESH ON 4" COMPACTED STONE BASE AND FILL.
PROVIDE 4" THICK SLAB AT OFFICE AREA

KLEEN- RITE CORPORATION

14'-0"

12'-0"

17'-0"

B.O. CANOPY
345-00'

NEW WAREHOUSE FOR:

28'-0" MINIMUM CEILING CLEAR HEIGHT

4"
2'-8"

5'-0"

37'-9"

3'-0"

MEZZANINE LEVEL
350.00'

257 SOUTH 9TH STREET COLUMBIA PA 17512

11'-9"

31'-2 1/2"

14'-2 1/2"

HEAD BOX AND


DOWNSPOUT
25'-0" O.C. CONNECT
TO UNDER GROUND
STORM WATER
PIPING

"CARLISLE" SINGLE-PLY EPDM ON


7" RIGID INSULATION & 1 1/2" METAL DECK

FABRAL 24 GA. CONCEALED


FASTENER "SELECT SERIES"
R-RO W/ RIGID INSULATION W/
INSULATED LINER PANEL
LP-14 OR EQUAL.

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A302.DWG 10-13-14 11:09 AM PRINTED BY: JOESLAGLE

PROPOSED ALTERNATE WALL SECTION ( SINGLE WYTHE MASONRY )


SCALE: 3/16"=1'-0"

30% PROGRESS DRAWING

PROPOSED BUILDING WALL SECTION

257 SOUTH 9TH STREET COLUMBIA PA 17512

KLEEN- RITE CORPORATION

NEW WAREHOUSE FOR:

8" SPLIT FACE CMU SINGLE


WYTHE REINFORCED
MASONRY WALL.

ROOM FINISH SCHEDULE


CEILINGS

MISCELLANEOUS

REMARKS

CASEWORK

PAINTED DOORS

PAINTED HOLLOW METAL FRAMES

STAINED WOOD TRIM/CASING

MATERIAL

STAINED DOORS

NOTE: SEE REMARKS COLUMN

NO FINISH / EXISTING TO REMAIN

HGT. AFF
EXPOSED DECK & STRUCTURE

( 2 X 4 ) ACT WITH CENTER SCORE

RECLAIMED BARN BOARDS

PAINTED DRYWALL

ACOUSTICAL CEILING TILE ( 2 X 4 )

NOTE: SEE REMARKS COLUMN

NO FINISH / EXISTING TO REMAIN

MATERIAL

VINYL WALLCOVERING

FIBER CEMENT BOARD & BATTEN

EPOXY PAINTED CMU

FIBERGLASS PANEL (FRP)

PORCELAIN WALL TILE

PAINTED DRYWALL

NOTE: SEE REMARKS COLUMN

NO FINISH / EXISTING TO REMAIN

EPOXY COVE BASE

VINYL BASE

WOOD BASE

CARPET TILE

NOTE: SEE REMARKS COLUMN

MATERIAL

NO FINISH / EXISTING TO REMAIN

MATERIAL

SEALED CONCRETE
(APPLIED URETHANE SEALER)

MATERIAL

EPOXY

ROOM NAME

VINYL TILE

WALLS

SHEET GOOD / PLANK

BASE

PORCELAIN TILE

FLOOR

ROOM NUMBER

ROOM

101

DRIVER CHECK-IN

9'-0"

102

DRIVER RESTROOM

8'-0"

103

MECH / ELEC

9'-0"

104

CONFERENCE ROOM

9'-0"

105

STORAGE ROOM

9'-0"

106

JANITOR

9'-0"

107

KITCHENETTE

9'-0"

108

WOMEN

8'-0"

109

MEN

8'-0"

110

ELECTRICAL

9'-0"

111

OFFICE

9'-0"

112

CLERK'S AREA

9'-0"

113

DATA CLOSET

9'-0"

114

OFFICE CORRIDOR

9'-0"

115

SWEEP & DUMP

N/A

--

116

FIRE PUMP ROOM

N/A

--

117

WAREHOUSE

N/A

--

118

SHOWER ROOM

201

MEZZANINE

--

UNDERSIDE OF MEZZANINE TO BE PAINTED WHITE

202

ELEVATOR EQUIPMENT

--

WALLS AND CEILINGS TO BE PAINTED WHITE

8'-0"

FINISH NOTE(S):
VERIFY ALL FINISHES w/ OWNER AND ARCHITECT.
PROVIDE A SMOOTH, HARD, NONABSORBENT SURFACE ON WALLS WITHIN 2'-0" OF URINAL(S) AND WATER CLOSET(S) TO A HEIGHT OF 4'-0" A.F.F. (IBC 2009 SECTION 1210)
PROVIDE (1) COAT OF PRIMER AND (1) FINISH COAT MINIMUM FOR ALL GYP. BD. SURFACES. CERTAIN COLORS MAY REQUIRE TINTED PRIMER AND ADDITIONAL COATS TO ENSURE PROPER COVERAGE.
PROVIDE FINISHES THAT ARE CLASS 'C' OR BETTER.

FR. DEPTH

HARDWARE
GROUP

SIGNAGE

3'-0" x 7'-2"

ALUM

HM

5 3/4"

DRIVER CHECK-IN

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

NOTE: DOORS TO REMAIN UNLOCKED DURING


NORMAL BUSINESS HOURS

102-1

DRIVER RESTROOM

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

103-1

MECH / ELEC

3'-0" x 6'-8"

HM

HM

5 3/4"

1 1/2 PR. HINGES


1 EA. PANIC EXIT DEVICE
1 EA. DOOR CLOSER
1 EA. WALL STOP
3 SILENCERS

104-1

CONFERENCE ROOM

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

105-1

STORAGE ROOM

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

106-1

JANITOR

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

108-1

WOMEN

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

109-1

MEN

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

110-1

ELECTRICAL

3'-0" x 7'-0"

HM

HM

5 3/4"

111-1

OFFICE

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

113-1

DATA CLOSET

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

114-1

OFFICE CORRIDOR

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

116-1

FIRE PUMP ROOM

3'-0" x 7'-0"

HM

HM

5 3/4"

117-1

WAREHOUSE

12'-0" x 14'-0"

INSUL STL

HM

5 3/4"

117-2

WAREHOUSE

10'-0" x 10'-0"

INSUL STL

HM

5 3/4"

117-3

WAREHOUSE

10'-0" x 10'-0"

INSUL STL

HM

5 3/4"

117-4

WAREHOUSE

10'-0" x 10'-0"

INSUL STL

HM

5 3/4"

117-5

WAREHOUSE

10'-0" x 10'-0"

INSUL STL

HM

5 3/4"

117-6

WAREHOUSE

10'-0" x 10'-0"

INSUL STL

HM

5 3/4"

117-7

WAREHOUSE

10'-0" x 10'-0"

INSUL STL

HM

5 3/4"

117-8

WAREHOUSE

10'-0" x 10'-0"

INSUL STL

HM

5 3/4"

117-9

WAREHOUSE

10'-0" x 10'-0"

INSUL STL

HM

5 3/4"

117-10

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

117-11

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

117-12

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

117-13

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

117-14

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

117-15

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

117-16

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

117-17

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

117-18

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

117-19

WAREHOUSE

3'-0" x 7'-0"

HM

HM

5 3/4"

118-1

SHOWER RM.

3'-0" x 6'-8"

SC WOOD

HM

5 3/4"

201-1

MEZZANINE

(2) 3'-0" x 3'-4"

HM

HM

N/A

202-1

ELEVATOR MACHINE ROOM

3'-0" x 7'-0"

HM

HM

5 3/4"

4 1/2"x4 1/2"

1 1/2 PR. HINGES


1 EA. PRIVACY LOCK SET
1 EA. DOOR CLOSER
1 EA. WALL STOP
3 SILENCERS
1 1/2 PR. HINGES
1 EA. OFFICE LOCKSET
1 EA. DOOR CLOSER
1 EA. WALL STOP
3 EA. SILENCERS

4 1/2"x4 1/2"

4 1/2"x4 1/2"

ALL HARDWARE BY DOOR MANUFACTURER


ALL DOORS TO BE MANUALLY OPERATED

1 1/2 PR. HINGES W/ NON- REMOVABLE PINS @ EACH DOOR


1 EA. PANIC EXIT DEVICE
1 EA. DOOR CLOSER
1 EA. WALL STOP
1 ALUMINUM THRESHOLD
1 WEATHER STRIPPING

4 1/2"x4 1/2"

ALL GATE HARDWARE BY DOOR MANUFACTURER

SEE SCHED.

SEE SCHED.

6" X 30" VIEW PANEL


6" X 30" VIEW PANEL

SWINGING GATES
-

1.

A.
B.

ALL HARDWARE TO BE HEAVY DUTY

E.

PROVIDE H/C SIGNAGE AS REQUIRED.


PROVIDE TACTILE EXIT SIGNS AS NOTED ON SCHEDULE, AT
ALL EXIT ACCESS AND EXIT DOORS.
KEY OPERATED BOLT MUST USE A LOCK WHICH IS READILY
DISTINGUISHABLE AS LOCKED.
FINAL LOCKSET ASSIGNMENTS SHALL BE APPROVED BY
OWNER.
ALL SWINGING & SLIDING DOORS ARE 1 3/4" THICK UNLESS
NOTED OTHERWISE.

SEE SCHED.

SEE SCHED.

SEE SCHED.

SEE SCHED.
10"

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A601.DWG 10-13-14 11:12 AM PRINTED BY: JOESLAGLE

VT

6" X 30" VIEW PANEL

GENERAL NOTES:

D.
SEE SCHED.

EXTERIOR ALUMINUM W/ GLASS

DOOR SCHEDULE NOTES:

C.

REMARKS

DRIVER CHECK-IN

SEE SCHED.

SEE SCHED.

DR. MAT'L DR. TYPE FR. MAT'L

101-1

HARDWARE FINISH TO BE SELECTED BY OWNER

SEE SCHED.

SIZE

101-2

NOTE: ALL DOORS TO BE "B"


LABEL RATED FIRE DOORS

ROOM NAME

30% PROGRESS DRAWING

DOOR / FINISH SCHEDULES

MARK

ALL HARDWARE BY ALUMINUM DOOR MANUFACTURER


1 EA ADAMS RITE DEAD LOCK
1 EA LCN CONCEALED OVERHEAD CLOSER
1 EA. PUSH / PULL

257 SOUTH 9TH STREET COLUMBIA PA 17512

DOOR SCHEDULE

STANDARD HARDWARE SCHEDULE

KLEEN- RITE CORPORATION

GROUP #

NEW WAREHOUSE FOR:

1.
2.
3.
4.

TOP OF PARAPET

FABRAL 24 GA.
CONCEALED
FASTENER "SELECT
SERIES" R-RO W/
INSULATED LINER
PANEL LP-14 OR
APPROVED EQUAL
SYSTEM.
8" CHAMFERED
GROUND FACE BAND
8" CHAMFERED
GROUND FACE BAND

FIN. FLR
333'-0"

WEST ELEVATION ALTERNATE MASONRY & VERTICAL METAL SIDING


SCALE: 1/16"=1'-0"

RWC CONDUCTOR W/
DOWNSPOUT (TYP)

ROOF LINE BEYOND

FABRAL 24 GA.
CONCEALED
FASTENER "SELECT
SERIES" R-RO W/
INSULATED LINER
PANEL LP-14 OR
APPROVED EQUAL
SYSTEM.
8" CHAMFERED
GROUND FACE BAND
8" CHAMFERED
GROUND FACE BAND

FIN. FLR
333'-0"

SPLIT FACE CMU

METAL STAIRS (TYP)

SOUTH ELEVATION ALTERNATE / MASONRY & VERTICAL METAL SIDING

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A201.DWG 10-23-14 2:57 PM PRINTED BY: JOESLAGLE

NEW WAREHOUSE FOR:

SCALE: 1/16"=1'-0"

30% PROGRESS DRAWING

257 SOUTH 9TH STREET COLUMBIA PA 17512

SPLIT FACE CMU

KLEEN- RITE CORPORATION

POURED CONCRETE
FOUNDATION

SOUTH & WEST EXTERIOR ELEVATIONS / MASONRY & METAL

HORIZONTAL BAND

PARAPET
BRICK CORBEL (TYP)

COMMERCIAL BRICK
4 X 12
8" CHAMFERED
GROUND FACE BAND

8" CHAMFERED
GROUND FACE BAND

FIN. FLR
333'-0"

SPLIT FACE BAND

WEST ELEVATION / ALL MASONRY

ROOF LINE BEYOND

COMMERCIAL BRICK
4 X 12

RWC CONDUCTOR W/
DOWNSPOUT (TYP)

BRICK CORBEL (TYP)

COMMERCIAL BRICK
4 X 12

FIN. FLR
333'-0"

8" CHAMFERED
GROUND FACE BAND

SPLIT FACE CMU


SPLIT FACE CMU

METAL STAIRS (TYP)

SOUTH ELEVATION / ALL MASONRY

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A202.DWG 10-23-14 2:55 PM PRINTED BY: JOESLAGLE

NEW WAREHOUSE FOR:

SCALE: 1/16"=1'-0"

30% PROGRESS DRAWING

257 SOUTH 9TH STREET COLUMBIA PA 17512

POURED CONCRETE
FOUNDATION

KLEEN- RITE CORPORATION

FIN. FLR
333'-0"

SOUTH & WEST EXT. ELEVATIONS / ALTERNATE ALL MASONRY

SCALE: 1/16"=1'-0"

LIGHT SANDBLASTED
PRECAST PANEL

PRECAST PANEL

MEDIUM
SANDBLASTED
PRECAST PANEL

LIGHT SANDBLASTED
PRECAST PANEL
FIN. FLR
333'-0"

POURED CONCRETE
FOUNDATION

WEST ELEVATION ALTERNATE OPTION # 2


SCALE: 1/16"=1'-0"

RWC CONDUCTOR W/
DOWNSPOUT (TYP)

PRECAST PANEL

MEDIUM
SANDBLASTED
PRECAST PANEL

LIGHT SANDBLASTED
PRECAST PANEL
FIN. FLR
333'-0"

METAL STAIRS (TYP)

SOUTH ELEVATION / PRECAST PANEL

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\A203.DWG 10-23-14 2:58 PM PRINTED BY: JOESLAGLE

NEW WAREHOUSE FOR:

SCALE: 1/16"=1'-0"

30% PROGRESS DRAWING

257 SOUTH 9TH STREET COLUMBIA PA 17512

POURED CONCRETE
FOUNDATION

KLEEN- RITE CORPORATION

POURED CONCRETE
FOUNDATION

SOUTH & WEST EXT. ELEVATIONS / ALTERNATE PRECAST PANEL

LIGHT SANDBLASTED
PRECAST PANEL

Wind Load:
Basic Wind Speed (3-second gust) = 90 MPH
Wind Importance Factor, Iw = 1.0
Building Category = II
Exposure Category = B
Internal Pressure Coefficient, GCpi = 0.18
Wind Design Pressure (MWFRS) = 13 PSF
Net Uplift Load Varies: Min. Net Uplift load = 10 PSF
Earthquake Design Data:
Building Category = II
Seismic Importance Factor, Ie = I.0
Mapped Spectral Response Accelerations:
Ss = 0.226
S1 = 0.056
Site Class = D
Spectral Response Coefficients:
Sds = 0.241
Sd1 = 0.090
Seismic Design Category = B
Basic Seismic Force-Resisting System = Steel System Not Specifically Designed for
Seismic
Design Base Shear = 72 kips (0.7E For ASD Load Combinations)
Seismic Response Coefficient, Cs = 0.084
Response Modification Factor, R = 3
Analysis Procedure = Equivalent Lateral Force Procedure
Concrete Masonry Design Method:
Design per ASD
Loads indicated are ASD loads
Concrete Design Method:
Design per LRFD
Loads indicated are ASD loads
Structural Steel Design Method:
Design per ASD
Loads indicated are ASD loads
Steel Joists Design Method:
Design per ASD
Loads indicated are ASD loads
STRUCTURAL SPECIFICATIONS AND GENERAL CONDITIONS (04-12)
GENERAL
1.
Where these specifications conflict with other project specifications, these
specifications shall govern.
2.
C.S. Davidson, Inc. will assume no responsibility and/or liability for problems
which arise from failure to follow these plans, specifications, and the design
intent they convey or for problems which arise from others' failure to obtain
and/or follow the Engineer's guidance.
3.
All work shall be performed in accordance with local applicable codes and
regulations. Appropriate safety measures satisfying local and OSHA
requirements shall be provided.
4.
Proper temporary bracing of all construction work in progress is the
Contractor's responsibility.
5.
If during demolition existing conditions do not agree with information shown on
the design drawings, the Contractor shall notify the Engineer immediately.
6.
The Contractor shall be responsible for the location and protection of all
existing utilities during construction and the repair of any damaged facilities.
7.
Sections and details shown, while drawn for specific locations, are intended to
establish the general types of details to be used throughout.
8.
Drawings should not be scaled. Contact the Engineer for clarification of any
dimension in question.
9.
Anchor bolt layout shall be performed under the direction of a professional
land surveyor.
10.
All dimensions shall be verified by the Contractor. Layout shall be checked
and coordinated between all construction documents and specifications prior
to the start of work.
11.
Shop drawings prepared by the subcontractors, suppliers, etc. shall be
reviewed by the Engineer for conformance with design concept only. Each
shop drawing submitted shall be stamped, initialed and dated as being
reviewed by
the construction manager/general contractor. Work shall not
begin without the review by the Engineer.
12.
Any engineering design provided by others and submitted for review or record
shall bear the stamp and signature of a professional structural engineer
registered in the state in which the project is located.
CONSTRUCTION PROCEDURES AND SAFETY REQUIREMENTS
1.
The contract structural drawings and specifications represent the finished
structure. Unless otherwise indicated, they do not indicate the means or
methods of construction.
2.
Provide all measures necessary to protect the workmen and other persons during
construction. Provide all necessary measures to avoid excessive stresses and to
hold the structural elements in place during construction. Such measures shall
include, but not be limited to, bracing, shoring for construction equipment,
shoring for earth banks, forms, scaffolding, planking, safety nets, support and
bracing for cranes and hoists, guying, etc.
3.
Engage properly qualified persons to determine where and how temporary
precautionary measures shall be used. Observation visits to the site by structural
engineer's field representative shall not include the items noted above.
4.
Supervise and direct the work so as to maintain sole responsibility for all
construction means, methods, techniques, sequences, and procedures. Retain
the services of a professional structural engineer licensed in the state in which
the project is located to design and supervise any scaffolding for workmen, and
all shoring of forms and elements of the construction.
DRAWING LIST
SHEET
NUMBER
S001
S002
S101
S102
S103
S201
S202
S203
S204
S301
S302
S303
S304
S401
S402

SHEET NAME
GENERAL NOTES
TYPICAL SCHEDULES
FOUNDATION PLAN
MEZZANINE FRAMING PLAN
ROOF FRAMING PLAN
FOUNDATION DETAILS
FOUNDATION DETAILS
WALL FOOTING SECTIONS
FOUNDATION SECTIONS
FRAMING DETAILS
FRAMING DETAILS
FRAMING SECTIONS
WALL DETAILS
LATERAL BRACING ELEVATIONS
LATERAL BRACING DETAILS

SHEET ISSUE
DATE
09/23/14
09/23/14
09/23/14
09/23/14
09/23/14
09/23/14
09/23/14
09/23/14
10/01/14
09/23/14
09/23/14
09/23/14
10/01/14
10/01/14
09/29/14

STEEL STAIR DESIGN


1.
The stair supplier shall be responsible for the design of all stairs, landings, and
connections, unless noted otherwise. Drawings and calculations sealed by a
structural engineer licensed in the state in which the project is located shall be
submitted to the engineer for approval.
2.
Stairs & landings shall be designed for a minimum live load of 100 PSF in
addition to any applicable dead loads; including their self-weight.
3.
Contractor shall coordinate the steel stair design with masonry wall construction
to ensure proper bearing conditions & attachments are provided.
STEEL JOISTS
1.
Steel joists shall be manufactured in accordance with the specifications of the
Steel Joist Institute (SJI), latest edition. The manufacturer shall verify all design
applications of steel joists shown on the drawings. Steel joists shall be
manufactured by a member of the Steel Joist Institute.
2.
End bearings and bridging details shall be as stipulated in the SJI Specifications
and as shown on the drawings.
3.
Provide the appropriate size of bridging and number of bridging rows as required
by the SJI specifications. Exact bridging sizes and locations shall be determined
by the joist manufacturer. Contractor to coordinate joist bridging locations with
MEP drawings.
4.
Submit shop drawings to the Engineer for approval prior to fabrication.
5.
Provide one shop coat of primer paint.
6.
Welding across steel joist chords will not be permitted; all welding shall run
parallel to joist chords.
METAL DECKING
1.
Installation of all decking shall be in strict accordance with the Steel Deck
Institute (SDI) specifications and with manufacturer's recommendations. Steel
deck shall be manufactured by a member of the Steel Deck Institute.
2.
All floor deck shall be galvanized and all roof deck shall be painted, U.N.O.
Composite metal deck for floor slabs shall have a min. yield strength = 40 KSI.
Deck shall be a minimum 3-span continuous where possible.
3.
Deck shall be attached to the steel structure using 5/8" diameter puddle welds
at 12" o.c. with sidelaps fastened with #10 TEK screws at 12" O.C., U.N.O.
Alternate fasteners must be approved by the Engineer.
4.
Store and handle decking so as to prevent damage.
5.
Submit shop drawings to the Engineer for approval prior to installation.
6.
Provide a 1/4" thick bent plate or angle at all floor/roof edges U.N.O.
7.
Provide accessories as needed to provide a complete system. Contractor shall
refer to Manufacturer's specifications for accessories for specialty deck types
(e.g. Epicore, Arch Deck, etc.).
8.
All floor or roof deck penetrations > 6" (square or dia.) shall be properly
reinforced with angle frames or slab reinforcing as specified by the Engineer.
9.
All welding shall be performed in accordance with the requirements of the AWS
Code, D1.3, Structural Welding Code - Sheet Steel, latest edition, and shall be
performed only by qualified welders.
PRECAST CONCRETE FLOOR AND WALL PANELS
1.
Planks shall be pretensioned, solid or hollow core, flat slabs machine cast by a
member of the Precast Concrete Institute and designed for the loads listed on
the drawings and in accordance with Precast Concrete Institute standards.
2.
Shop drawings & sealed calculations prepared by a structural engineer licensed
in the state in which the project is located shall be submitted to the Engineer for
approval prior to fabrication and shall include all material strengths and
specifications.
3.
See drawings for thickness and spanning directions.
4.
All grout keys shall be properly filled for full length and properly tied into
bearing points as detailed on the drawings.
5.
Fabricate plank to a length tolerance of 1/2 inch.
6.
Provide openings in precast for all penetrations. No field cutting of plank for
openings will be permitted. For openings up to 8 inches in diameter field
drilling or coring may be allowed provided that all such openings be marked
and approved by the precast manufacturer prior to any drilling or coring. All
openings over 8 inches in diameter must be shop-formed or framed.
7.
Design reinforcement for any plank with field-drilled or cored openings to
support all dead and live loads with any one strand cut.
8.
Supply all headers required for plank support around openings as required.
STRUCTURAL STAINLESS STEEL
1.
Stainless steel design and fabrication shall be in accordance with the ASCE-8
Specification for the Design of Cold-Formed Stainless Steel Structural Members,
latest edition.
2.
Stainless steel shall be annealed austenitic, Type 304 (18-8 Stainless).
3.
All welding shall be performed in accordance with the requirements of the AWS
Code, D1.6, Structural Welding - Stainless Steel, latest edition, and shall be
performed only by qualified welders.
4.
Available tensile strength of weld metal assumed for design is 80 ksi.
5.
Shop drawings for the fabrication and erection of all structural steel shall be
submitted to and approved by the Engineer prior to fabrication.
6.
The Contractor shall notify the Engineer of any fabrication or erection errors or
deviations and receive written approval before field corrections are made.
7.
Bolted connections of structural steel shall be made using high strength stainless
steel bolts conforming to ASTM F593 (AISI 304). Bolts shall be 3/4" minimum
diameter unless noted otherwise.
8.
Simple shear connections shall be standard double angle or shear plates, unless
noted otherwise. All bolted connections shall have a minimum of 2 bolts.
9.
Anchor bolts shall conform to the requirements of ASTM F593. Bolts shall be 3/4"
minimum diameter unless noted otherwise. All columns shall have a minimum of
4 anchor bolts unless noted otherwise.
10.
The Contractor shall be responsible for the temporary bracing of all steel during
erection and until construction is complete.
11.
The Contractor shall furnish all plates, clips and seat angles and connections for
completion of the structure, even if such items are not specifically called for on the
Structural Drawings.
12.
Structural and miscellaneous steel fabricators shall be responsible for obtaining
all field dimensions necessary for completion of their work.
13.
Fillet welds shall be minimum of 3/16-inch, unless noted otherwise. Welded
surfaces shall be prepared and refinished as required by the AWS D1.6 Code
Specifications.

COLD-FORMED STEEL FRAMING


1.
All structural members shall be in conformance with the Specification for the Design of
Cold-Formed Steel Structural Members, AISI, latest edition. Manufacturer shall verify all
design applications of framing members shown on the drawings.
2.
Cold-formed steel supplier shall prepare complete structural design calculations for all
framing members and accessories. Framing shall be designed for the loads listed on the
drawings and all applicable building code requirements. Framing shall also be designed to
meet the deflection criteria listed in items 3, 4, & 5.
3.
Interior and Exterior Walls: Horizontal deflection shall not exceed 1/360 of the wall height
unless supporting masonry veneer, in which case deflection shall not exceed 1/600 of the
wall height.
4.
Floor Joists or Trusses: Vertical deflection shall not exceed 1/360 of the span for Live Load,
and 1/240 of the span for Total Load.
5.
Roof Joists or Trusses: Vertical deflection shall not exceed 1/360 of the span for Live Load,
and 1/240 of the span for Total Load. (If members do not support a plaster or drywall
ceiling, deflection shall not exceed 1/240 of the span for Live Load, and 1/180 of the span
for Total Load).
6.
Cold-formed steel trusses shall be designed for the following loads indicated in items 7-10:
7.
All wind loads and snow loads, including balanced, unbalanced, drift, & sliding snow, shall
be determined using the 2009 International Building Code (IBC).
8.
Minimum Top chord live load = 35 psf
9.
Top chord dead load = 10 psf
10.
Bottom chord dead load = 10 psf
11.
Supplier shall submit the following items, at a minimum, for review: 1.) Product data.
2.) Shop drawings showing framing, accessories, anchorages, and connection details.
3.) Structural design calculations sealed by a structural engineer licensed in the state in
which the project is located. 4.) Manufacturer's installation instructions for framing
members and accessories.
12.
All framing members shall be formed from corrosion-resistant steel corresponding to the
following requirements: 1.) 16 Gage (54 Mils), 14 Gage (68 Mils), and 12 Gage (97 Mils)
framing components shall be formed from steel conforming to the minimum requirements
of ASTM A653, Grade D, with a minimum yield stress of 50,000 psi. 2.) 18 gage (43 Mils)
and 20 gage (33 Mils) framing components shall be formed from steel conforming to the
minimum requirements of ASTM A653, Grade A with a minimum yield stress of 33,000 psi.
3.) Galvanized framing products shall be coated in accordance with the requirements of
ASTM A525.
13.
When masonry veneer is anchored to cold-form steel backing, framing shall be corrosion
resistant and have a minimum base metal thickness of 0.043 in. (43 mils. - 18 gage).
14.
Connections of all framing components shall be with self-drilling screws or welding. When
connecting materials greater than 1/4" in thickness, holes shall be pre-drilled prior to
installation of fastener. Screws shall be of sufficient size to insure the strength of the
connection. Wire tying of framing components shall not be permitted. All welds shall be
touched up with paint conforming to the manufacturer's requirements.
15.
All welding shall be performed in accordance with the requirements of the AWS Code, D1.3,
Structural Welding Code - Sheet Steel, latest edition, and shall be performed only by
qualified welders.
16.
End bearing and bridging details shall be as stipulated in the AISI Specifications and as
shown on the drawings.
17.
Field cutting of steel framing members shall be by saw or shear. Torch cutting will not be
permitted.
18.
Temporary bracing shall be provided and remain in place until work is permanently
stabilized.
19.
Installation - Stud Wall Systems:
A.
Where splicing of track is necessary between stud spacings, a piece of stud shall be
placed between adjacent tracks and fastened by weld or screw to each side of the
track, each end.
B.
Splicing of framing components, other than track or multi-story stud walls, is not
permitted.
C.
Studs shall be plumbed, aligned and secured to the continuous runner tracks at each
end and each side.
D.
Mechanical bridging of the type and spacing described shall be installed prior to the
installation of facing materials. Minimum spacing of bridging shall be 4'-0", unless
indicated otherwise by light-gauge framing engineer.
E.
Installation of sheathing, wallboard or any other collateral material shall be performed
in accordance with the product manufacturer's specification
20.
Installation - Horizontal Joists:
A.
Provide web stiffeners at support locations where indicated.
B.
Mechanical bridging of the type and spacing described shall be installed before
loading.
C.
End blocking shall be provided where joist ends are not restrained against rotation.
D.
Provide additional framing around openings when the width of the opening exceeds
the typical joist spacing.
E.
During construction, the joist system shall not be loaded beyond the limits for which
it was designed.
F.
Minimum end bearing shall be 1 1/2".

MIN. 28-DAY
COMP.
STRENGTH

MAX.
W/C
RATIO

TYPE 1
PORTLAND
CEMENT

SLUMP
RANGE

(1) Footings & slabs-on-metal deck

3000 PSI

0.65

5 BAGS

3" - 6"

(2) Interior slabs-on-grade

4000 PSI

0.5

6 BAGS

3" - 6"

(3) Piers, pile caps, & grade beams

4500 PSI

0.5

6 BAGS

3" - 6"

TYPE OF CONSTRUCTION

SPECIAL INSPECTION REQUIREMENTS


The following types of work require special inspection based on Section 1704 of the 2009 International
Building Code. The owner will employ special inspectors who shall provide special inspections for
compliance with the construction documents and other references noted. Reports shall be submitted to
the Engineer and Building Official on a periodic basis. A final report shall be submitted documenting
required special inspections and correction of any discrepancies prior to the end of construction.
1.

2.

3.

Soils
A.

Verify materials below footings are adequate to achieve the design bearing
capacity.
B.
Verify excavations are extended to proper depth and have reached proper
material.
C.
Verify use of proper materials, densities, and lift thicknesses during placement
and compaction of controlled fill with a total depth greater than 12".
D.
Prior to placement of controlled fill, observe subgrade and verify that site has
been prepared properly.
Concrete Construction
A.
Periodic inspection of reinforcing steel, including prestressing tendons & placement
for compliance with approved Construction Documents and ACI 318, Sections 3.5
and 7.1 - 7.7.
B.
Continuous inspection of welding of reinforcing steel in accordance with AWS D1.4
and ACI 318, Section 3.5.2.
C.
Continuous inspection of bolts installed in concrete prior to and during placement of
concrete where allowable loads have been increased.
D.
Periodically verify the use of required concrete design mixtures, in accordance with
ACI 318, Chapter 4 and Section 5.2 - 5.4.
E.
Verify sampling of fresh concrete to determine slump, air content and temperature
when making specimens for strength tests, in accordance with ACI 318, Sections
5.6 and 5.8.
F.
Continuous inspection of concrete and shotcrete placement for proper application
techniques in accordance with ACI 318, Sections 5.9 and 5.10.
G.
Periodic inspection for maintenance of curing temperatures and techniques to
ensure compliance with ACI 318, Sections 5.11 - 5.13.
H.
Continuous inspection of application of prestressing forces and grouting of bonded
prestressing tendons in the seismic-force-resisting system, in accordance with ACI
318, Sections 18.18.4 and 18.20.
I.
Periodically inspect erection of precast concrete members to ensure compliance
with ACI 318, Chapter 16.
J.
Periodic verification of in-situ concrete strength, prior to stressing of tendons in
posttensioned concrete, and prior to the removal of shoring and forms from beams
and structural slabs, in accordance with ACI 318, Section 6.2.
Steel Construction
A.
Welding inspection shall be in compliance with AWS D1.1. The basis for welding
inspector qualification shall be AWS D1.1.
B.
Periodically verify compliance with framing and connection details on the
construction documents.
C.
Verify that high-strength bolts, nuts, washers, structural steel, and weld filler
materials conform to applicable standards in the construction documents. Verify
manufacturer's certificate of compliance or certified mill test reports.
D.
Periodically inspect installation of high-strength bolts in accordance with AISC
Specifications.
E.
Verify pre-installation testing and calibration procedures; that bolted parts are in
snug contact; and installation procedure for bolts requiring pre-tensioning.
F.
Periodically inspect bolts requiring pre-tensioning when using the turn-of-nut
method with matchmarking, the direct tension indicator method, or the alternate
design fastener (twist-off bolt) method.
G.
Continuously inspect bolts requiring pre-tensioning when using the calibrated
wrench method or turn-of-nut method without matchmarking.
H.
Verify bolted parts are in snug contact, and monitor installation and tightening on a
periodic basis for bolts requiring only snug tight condition.
I.
Periodic inspection of welding for single-pass fillet welds <5/16" and floor and deck
welds.
J.
Continuous inspection of complete and partial penetration groove welds, multi-pass
fillet welds, and single-pass fillet welds >5/16".
K.
Inspection of Fabricators: When a fabricator is not registered and approved to
perform work without special inspection, or does not have a certificate of
compliance, a special inspector shall verify that the fabricator maintains detailed
fabrication and quality control procedures that provide a basis for inspection control
of the workmanship and the fabricator's ability to conform to approved construction
documents. Procedures shall be reviewed for completeness and adequacy relative
to the code requirements for the fabricator's scope of work.

STRUCTURAL STEEL
1.
All steel construction shall be in accordance with the Specification for Structural Steel
Buildings, March 9, 2005 (AISC 360), the Specification for Structural Joints Using ASTM A325
or A490 Bolts, June 30, 2004, the Code of Standard Practice for Steel Buildings and Bridges,
March 18, 2005 (AISC 303), and the AISC Steel Construction Manual, 13th edition.
2.
All welding shall be performed in accordance with the requirements of the AWS Code, D1.1,
Structural Welding Code - Steel, latest edition, and AISC Specifications using the proper
electrode from AWS D1.1 Table 3.1 and performed only by qualified welders.
3.
Structural steel shall conform to the requirements of ASTM A992, with a minimum yield stress
of 50 ksi for all wide flange and WT shapes. All other shapes, miscellaneous plates, and
connection material shall conform to ASTM A36.
4.
Square or rectangular structural steel sections (HSS) shall conform to the requirements of
ASTM A500, Grade B, with a minimum yield stress of 46 ksi.
5.
Round hollow structural steel sections (HSS) shall conform to the requirements of ASTM
A500, Grade B, with a minimum yield stress of 42 ksi.
6.
Structural steel pipe shall conform to the requirements of ASTM A53, Type S, Grade B, with a
minimum yield stress of 35 ksi.
7.
All galvanized structural steel shall conform to the requirements of ASTM A123.
8.
Shop drawings for the fabrication and erection of all structural steel shall be submitted to and
approved by the Engineer prior to fabrication.
9.
The Contractor shall notify the Engineer of any fabrication or erection errors or deviations and
receive written approval before field corrections are made.
10.
Fabricator and erector of structural steel shall be AISC certified. A current copy of the AISC
certificate shall be submitted to the Engineer prior to fabrication and erection. If not certified by
AISC, fabricator shall be subjected to the special inspection requirements.
11.
Steel Connection Design: All steel connections shall be designed by a professional engineer
registered in the state of Texas, in accordance with the AISC 13th Edition Steel Manual. The
fabricator shall submit sealed connection design calculations for all shear, moment, and
bracing connections before shop drawings are submitted for review. Connections varying
from typical details shown shall be submitted with design calculations for approval prior to
submitting shop drawings.
12.
The faying surfaces at slip-critical connections shall be Class A surfaces, and shall not be
painted or primed. Galvanized surfaces shall be roughened by means of hand wire brushing
as indicated in the 2004 RCSC specification.
13.
Simple shear connections shall be standard double angle or shear plates, unless noted
otherwise. All bolted connections shall have a minimum of 2 bolts.
14.
All high strength bolts shall be snug tight unless noted otherwise. A snug tight condition is as
defined in Section 1.2.2. in the AISC Design Guide 17. Bolts used in slip-critical connections
shall be pretensioned in accordance with the 2004 RCSC specification.
15.
Anchor bolts shall conform to the requirements of ASTM F1554, with a minimum yield strength
of 36 ksi, unless noted otherwise. Bolts shall be 3/4" minimum diameter unless noted
otherwise. All columns shall have a minimum of 4 anchor bolts unless noted otherwise.
16.
The Contractor shall be responsible for the temporary bracing of all steel during erection and
until construction is complete.
17.
The Contractor shall furnish all plates, clip and seat angles, and connections for completion of
the structure, even if such items are not specifically called for on the structural drawings.
18.
Structural and miscellaneous steel fabricators shall be responsible for obtaining all field
dimensions necessary for the completion of their work.
19.
Minimum size of fillet welds, unless otherwise noted, is to be 3/16-inch fillet. Chip, wirebrush
clean, and prime paint all field welds.

ARCHITECTS

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603
T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.
ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

REVISIONS
NUMBER

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

DATE

REVISE BY

DATE

10/01/2014

DRAWN BY

DHA
4226.8.29.00

PROJECT NUMBER

GENERAL NOTES

Lateral Soil Load:


Soil Unit Weight = 120 PCF
At-Rest Pressure = 60 PSF/FT.
Active Pressure = 40 PSF/FT.
Surcharge Loading = 300 PSF

CAST-IN-PLACE CONCRETE CONSTRUCTION


1.
All concrete work shall conform to the requirements of ACI 318, Building Code Requirements
for Reinforced Concrete, latest edition and ACI 301, Specifications for Structural Concrete for
Buildings, latest edition, including all revisions, except as modified herein.
2.
Concrete shall be supplied by a qualified ready-mixed concrete plant in accordance with the
requirements of items 3-12 and the Table below.
3.
Entrained Air = 4 to 7% for all exposed concrete, footings, piers, exterior slabs, all concrete
exposed to freezing temperatures, and where otherwise noted.
4.
Coarse aggregate shall be AASHTO NO. 57 stone. Maximum aggregate size = 1.5"
5.
Submit mix designs to Engineer for approval. No admixtures permitted without Engineer's
approval.
6.
Chloride containing admixtures are not permitted.
7.
Fine aggregate must be natural sand, unless approved by the Engineer.
8.
Air-entraining admixtures are not permitted on trowel finished slabs.
9.
For Interior Slabs-on-grade <= 4" thick: 1.) When specified as temperature and shrinkage
reinforcement, micro synthetic fibers made from 100% virgin homopolymer polypropelene
fibrillated fibers meeting ASTM C1116, Type III shall be added at a minimum rate of 1.5
lb/cu.yd. 2.) Fibrous reinforcement shall be manufactured by Propex, BASF, Grace, or
approved equal.
10.
For Interior Slabs-on-grade > 4" thick: 1.) When specified as temperature and shrinkage
reinforcement, cold-drawn steel fibers meeting ASTM A820 criteria shall be added at a
minimum rate of 25 lb. / cu. yd. or macro synthetic fibers made from virgin polyolefin shall have
an equivalent diameter between 0.016" and 0.05" with a minimum aspect ratio (length /
equivalent diameter) of 50, and added at a minimum rate of 4 lb. / cu. yd.
2.) Fibrous
reinforcement shall be manufactured by Propex, BASF, Grace, or approved equal. 3.) Slabs
must be laser-screeded, U.N.O.
11.
For Slabs-on-metal deck: 1.) When specified as temperature and shrinkage reinforcement,
cold-drawn steel fibers meeting ASTM A820 criteria shall be added at a minimum rate of 25 lb.
/ cu. yd. or macro synthetic fibers made from virgin polyolefin shall have an equivalent diameter
between 0.016" and 0.05" with a minimum aspect ratio (length / equivalent diameter) of 50,
and added at a minimum rate of 4 lb. / cu. yd. 2.) Fibrous reinforcement shall be
manufactured by Propex, BASF, Grace, or approved equal.
12.
For Exterior Slabs <= 5" thick: 6x6 W2.9 x W2.9 welded wire reinforcement, U.N.O.
13.
At Contractor's option, fly ash, ground granulated blast furnace slag, or other pozzolans may be
substituted for Portland cement, up to 25% of the cementitious content. Concrete mixes using
these materials must be approved by the Engineer.
14.
When concrete arrives at the project with slump below that suitable for placement, as indicated
by the
Specifications, water may be added only if neither the maximum permissible watercement ratio nor the maximum slump is exceeded. The water shall be incorporated by
additional mixing equal to at least half of the total mixing required. Discharge of the concrete
shall be completed within 1-1/2 hours, or before the truck drum has revolved 300 revolutions,
whichever comes first, after the introduction of the mixing water to the cement and aggregates
or the introduction of the cement to the aggregates. Truck batch slips must include time of
batching, total drum revolutions upon arrival at site, and quantity of water (in gallons) per cubic
yard available to be added to attain the maximum design water-cement ratio.
15.
Reinforcing steel shall be deformed, billet-steel conforming to ASTM A615 - Grade 60.
Welding of reinforcing steel must be approved by the Engineer and shall be performed in
accordance with the requirements of the AWS Code, D1.4, Structural Welding Code Reinforcing Steel latest edition and be performed only by qualified welders.
16.
When specified, welded wire fabric shall conform to ASTM A185 and supplied in flat sheets
only. Bar chairs are required at the recommended spacing for structural slabs.
17.
Reinforcing steel splices shall be ACI Class B splices unless indicated otherwise.
18.
Provide adequate bolsters, hi-chairs, support bars, etc., to maintain specified clearance for the
entire length of all reinforcing bars. Provide accessories which are plastic tipped or galvanized
with turned-up ends for reinforcement at all faces of exposed concrete, interior or exterior.
19.
Shop drawings for the fabrication and placement of reinforcing steel shall be submitted to and
approved by the Engineer before fabrication commences.
20.
Concrete shall be placed only after approval of the reinforcement and mix designs by the
acting special inspection agency or the Engineer. Contractor is responsible for coordinating
inspections prior to concrete placement.
21.
Schedule the pouring of foundations on the same day the excavation is completed.
22.
Cure all concrete in accordance with accepted ACI Standards and conformance to ACI 308.1,
Standard Specification for Curing Concrete, latest edition, for the worst case weather
conditions anticipated during the curing period. All concrete construction and procedures shall
conform to the requirements of ACI 306.1, Standard Specification for Cold Weather Concreting,
latest edition.
23.
No aluminum of any type shall be allowed in the concrete work unless coated to prevent
aluminum-concrete
reaction.
24.
Mechanically vibrate concrete. Slabs-on-grade need only be vibrated around floor ducts and
other embedded items.
25.
Do not place pipes, ducts, reglets or chases in structural concrete or composite floor systems
without approval of the structural engineer.
26.
Maximum free drop of any concrete = 5'-0".
27.
Chamfer all exposed concrete edges a minimum of 3/4" x 3/4".
28.
Provide a minimum of concrete cover for reinforcing bars as follows unless noted otherwise
on drawings: 1.) Footings = 3 inches earth face, 2 inches all others, U.N.O. 2.) Concrete walls,
beams, and piers = 2 inches earth face, 1-1/2 inches all others, U.N.O.
29.
Six (6) test cylinders shall be prepared for every 100 cubic yards of concrete placed on any
given day to represent all concrete placed on that day. Two (2) cylinders shall be tested at
seven (7) days and two (2) cylinders shall be tested at 28 days for verification of concrete
design strength with two (2) cylinder remaining.
30.
Concrete Finishes, as defined in Chapter 5 of ACI 301, shall be as follows, U.N.O.: 1.) Formed
surfaces not exposed to public view: Rough-form finish 2.) Formed surfaces exposed to
public view: Smooth-form finish. 3.) Walls as indicated: Rubbed finish 4.) Typical interior
commercial/industrial floor: Troweled finish 5.) Floors to receive ceramic tile, portland
cement, terrazzo, etc.: Scratch finish 6.) Exterior slabs on grade, walkways, etc.: Non-slip
broom finish
31.
Provide vertical control joints in concrete walls at a maximum 30'-0" O.C. spacing. Submit a
control joint location plan to the Engineer for approval prior to construction. Control joints shall
not be placed in concrete shear walls.
32.
Concrete submittals required to be reviewed and approved by the Engineer prior to cast-inplace concrete construction include, but are not limited to: Mix designs, Reinforcement Shop
Drawings, Control Joint Plans for Walls, and Control Joint Plans for Slabs.
33.
Slabs on Grade:
A.
Slabs on grade shall be placed in accordance with the requirements of ACI 302.1R.
B.
Slab finishing operations shall meet ACI Class 5 floor requirements in accordance with Chapter
8 of ACI 302. Floors receiving a surface hardener must be finished to ACI Class 6 floor
requirements.
C.
A minimum floor flatness (FF) / levelness (FL) tolerance meeting ACI FF 35/ FL 25
requirements shall be achieved through placing and finishing the slab per the guidelines set
forth in Table 8.15 of ACI 302.1R.
D.
Curing of slabs shall begin as soon as finishing operations are complete by either water curing,
wet covering, or liquid membrane-forming curing compound in accordance with Chapter 9 of
ACI 302.1R for a period of seven (7) days.
E.
Sawcut control joints must be completed within 1 to 4 hours of finishing and to a minimum depth
of 1/3 the slab thickness (1/4 for slabs with welded wire fabric). Provide joints at a maximum
15'-0" O.C. spacing Submit a sawcut joint location plan to the Engineer for approval.
F.
Slab joint sealant shall be a two-component, epoxy resin with a minimum shore A hardness of
80 in accordance with ASTM D 2240.
G.
Do not allow construction equipment on newly placed slabs for a minimum of seven (7) days.
H.
When strip pouring, allow seven (7) days before placing adjacent slab sections.
I.
A slab on grade pre-construction conference involving the Owner, Contractor and Engineer is
recommended to review installation procedures and requirements.
J.
Floor Design Loads - Rack Loading:
a.
Rack Post Spacing = __" x __" (single/double leg)
b.
Rack Post Base Plate Size = __" x __"
c.
Maximum Post Load = ____ lbs
d.
Subgrade Modulus, K = ___ pci
K.
Floor Design Loads - Fork Lift/Wheel Loads:
a.
Maximum Wheel Load = _____ lbs
b.
Wheel Spacing, s = __ in
c.
Load Repetitions = __
d.
Subgrade Modulus, K = ___ pci
e.
Tire Contact Area = __ sq. in.

257 SOUTH 9TH STREET COLUMBIA, PA 17512

Roof Load:
Dead Load = 20 PSF (includes structure weight)
Live Load = 30 PSF
Snow Load: (Roof Live Load May Control)
Ground Snow Load, Pg = 35 PSF
Flat Roof Snow Load, Pf = 24.5 PSF
Snow Exposure Factor, Ce = 1.0
Snow Load Importance Factor, Is = 1.0
Thermal Factor, Ct = 1.1

CONCRETE MASONRY CONSTRUCTION


1.
All concrete masonry shall conform to the requirements of ASTM C90 unless noted
otherwise. Concrete masonry construction shall conform to the requirements of ACI
530/ASCE 5/TMS 402, building code requirements for Masonry Structures, latest edition
and ACI 530.1/ASCE 6/TMS 602, Specifications for Masonry Structures, latest edition,
including all supplements.
2.
28 day design compressive strength of masonry (f'm) used is as follows: a.) Standard
Masonry = 1,500 psi. b.) Ivany = 2,800 psi
3.
The Contractor shall be responsible for the temporary bracing of all masonry construction.
Bracing shall remain in place until masonry has had sufficient time to gain design strength.
Where masonry attaches to floor and/or roof systems, bracing shall remain in place until
the diaphragm has been anchored in its final position.
4.
Grout lifts for reinforced masonry walls shall not exceed 5 feet in height. High lift grout
procedures may be used only after written approval is provided by the Engineer.
5.
All mortar shall conform to ASTM C270. Mortar shall be Type S (2/1/9 mix ratio of
cement/lime/sand) with an average 28 day compressive strength of 1,800 psi for above
grade walls (except Ivany Block). Mortar shall be Type M (4/2/12 mix) with an average 28
day compressive strength of 2,500 psi for Ivany walls, walls below grade, or walls
exposed to earth.
6.
Grout shall conform to the requirements of ASTM C476. Fill grouted cores, bond beams,
and wall reinforcement where shown on plans with 3,000 psi small aggregate concrete mix
with 8"-11" slump. Grout samples shall be tested per the Cast-in-place Concrete
Construction specifications.
7.
All steel lintels shall be temporarily shored where a height of masonry greater than half the
span of the lintel will be placed above the lintel prior to masonry gaining design strength.
Shoring shall remain in place until masonry has gained design strength and all required
permanent bracing is installed.
8.
All steel lintels for exterior masonry shall be galvanized. Lintel sizes, unless indicated
otherwise on the drawings, shall be as follows: a.) Clear opening of 3'-4" or less = (1) 5 x 31/2 x 5/16 angle (L.L.V.) per 4" of masonry wall thickness with 8" min. end bearing on 16"
thick of solid or grouted masonry. b.) Clear opening of 6'-4" or less = (1) 6 x 3 1/2 x 3/8
angle (L.L.V.) per 4" of masonry wall thickness with 8" min. end bearing on 16" thick of
solid or grouted masonry.
9.
Provide vertical control joints in above grade masonry walls so that the distance between
joints does not exceed the lesser of 1 1/2 times the overall wall height, or 25 feet. Control
joints shall not be placed greater than 8" from a bearing plate or jamb of an opening. A
control joint shall be placed at one side of an opening less than 6'-0" wide and at both sides
of openings over 6'-0" wide. Provide vertical control joints at intersections of reinforced &
unreinforced walls, U.N.O. Submit a shop drawing showing control joint locations to the
Engineer for approval prior to construction. Coordinate exact control joint & expansion joint
locations with architectural drawings.
10.
Horizontal joint reinforcement shall consist of truss type ASTM A82 cold drawn No. 9
gauge galvanized wire steel, located 16" o.c. Cross rods to be welded to side rods at 16"
o.c. to form a truss. Lap splices 6" minimum. Provide horizontal reinforcing in the two
courses above and below openings and at the top of walls or partitions.
11.
Masonry cores below grade shall be grouted solid.
12.
Head joints shall be mortared solid the full depth of the face shell. Webs shall be fully
mortared at grouted cores.
13.
A minimum of one course of masonry shall be grouted solid below transitions in masonry
thickness.
14.
Cold Weather Masonry Construction shall conform to the requirements of AC1
530.1/ASCE 6/TMS602, latest edition.
15.
Masonry stair shafts and elevator shafts shall be grouted solid, unless noted otherwise.
16.
Reinforcing steel shall be deformed, billet-steel conforming to ASTM A615 - Grade 60.
Welding of reinforcing steel must be approved by the Engineer and shall be performed in
accordance with the requirements of the AWS Code, D1.4, Structural Welding Code Reinforcing Steel latest edition and be performed only by qualified welders. Shop drawings
for the fabrication and placement of reinforcing steel shall be submitted to and approved
by the Engineer before fabrication commences.
17.
Submittals required to be reviewed and approved by the Engineer prior to concrete
masonry construction include, but are not limited to: Mix designs, Reinforcement Shop
Drawings, Vertical Control Joint Location Plans.
18.
Mortar shall be sampled and tested according to ASTM C 270, C 780, and C 1586.
19.
Wet setting of reinforcing steel is prohibited unless approved by the Engineer.

KLEEN-RITE CORPORATION

Mezzanine Load:
Dead Load = 55 PSF (includes structure weight)
Live Loads = 150 PSF

FOUNDATION CONSTRUCTION
1.
Allowable soil bearing pressure (net) assumed in design is 2,500PSF (pounds
per square foot) based on the geotechnical engineering investigation prepared
by _____________________, Project No. ______________ dated
______________.
2.
Soil bearing capacity shall be field verified by an approved soil testing agency
and documented in writing to the Engineer.
3.
If soil of design capacity is not encountered at footing elevations shown,
excavate to a depth necessary to attain design capacity and extend foundations
as required. Obtain Engineer's approval prior to lowering the foundations.
4.
The bottoms of all exterior footings shall extend a minimum of 3'-0" below
finished grade unless noted otherwise.
5.
Excavate all foundations to reasonable exact outline and depth avoiding overexcavation and cave-in of surrounding material. Bottoms of all foundations shall
be dry, soil proof-rolled, and rock surfaces leveled and cleared of loose debris
prior to pouring.
6.
Neatly level and trim all foundation excavations prior to setting steel.
7.
Pipes extending under footings shall be placed before footing is placed and the
void produced in laying the pipe shall be filled with 3,000 psi concrete.
8.
Thoroughly compact all foundation and slab subgrade material prior to
placement of stone bases or concrete.
9.
Provide weathertight covering for all foundations after excavation; do not expose
to rainwater or freezing.
10.
Where foundations are formed, backfill edges immediately after form removal.
11.
No fill or backfill shall be placed against retaining or foundation walls until grout
or concrete has attained design strength and supporting members are in place,
unless prior written approval is obtained from the Engineer.
12.
All backfill shall be granular material approved by the Engineer. Backfill shall be
deposited and machine compacted in 8-inch maximum layers. Compaction shall
be a minimum of 95% of the maximum dry weight density at the optimum
moisture content in accordance with ASTM D1557 (Modified Proctor) as verified
by a testing laboratory.
13.
All backfill adjacent to retaining structures shall be compacted using hand
operated equipment; no heavy equipment shall be allowed within 5 feet of any
wall.
14.
For all foundation construction that will be exposed to freezing temperatures
during construction, the bottom of all footings (interior and exterior) shall extend
a minimum of 3'-0" below grade (at no additional cost to the owner). Contractor
shall contact the Engineer of Record for approval to lower foundations and
obtain concrete pier sizes, if necessary.

NEW FACILITY FOR:

DESIGN DATA
Building Code = 2009 International Building Code

S001

LEGEND OF ACRONYMS & ABBREVIATIONS


&
@
A.C.T.
ADDL.
A.F.F.
ALUM.
ARCH.
BL
BLDG.
BLK.
B.O.F.
BRG.
BTWN.
C.
C.I.P.
CL
CLG.
CLR.
CMU
COL.
CONC.
CONT.
D. OR DP.
db
DIA.
DIM.
DN.
DWG.
EA.
E.F.
ENG.
ELEC.
ELEV.
EQ.
EQUIP.
E.W.
EX.
EXT.
F.E.
F.E./C
F.F.
F.G.
FIB.
FIN.
FLR.
FTG.
GA.
GALV.
GYP.
GPDW
HGT.

USE FOR "AND" WHEN APPROPRIATE


USE FOR "AT" WHEN APPROPRIATE
ACOUSTICAL CEILING TILE
ADDITIONAL
ABOVE FINISHED FLOOR
ALUMINUM
ARCHITECTURAL
BUILDING LINE
BUILDING
BLOCK
BOTTOM OF FOOTING
BEARING
BETWEEN
CARPET
CAST-IN-PLACE
CENTERLINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONTINUOUS
DEEP
REINFORCING BAR DIAMETER
DIAMETER
DIMENSION
DOWN
DRAWING
EACH
EACH FACE
ENGINEER(S) / ENGINEERING
ELECTRIC / ELECTRICAL
ELEVATOR
EQUAL
EQUIPMENT
EACH WAY
EXISTING
EXTERIOR
FIRE EXTINGUISHER
FIRE EXTINGUISHER WITH CABINET
FINISHED FLOOR
FINISHED GRADE
FIBERGLASS
FINISH(ED)
FLOOR
FOOTING
GAUGE
GALVANIZED
GYPSUM
GYPSUM DRYWALL
HEIGHT

H.M.
HORIZ.
HVAC
I.F.
INSUL.
INT.
L.
L.L.H.
L.L.V.
MAX.
MET.
MFG.
MIN.
MISC.
N.I.C
NO.
O.C.
O.F.
PennDOT
PL.
PLF
PNT.
PWD.
PSF
PSI
RAD.
REQ.
REINF.
RET.
SC
SECT.
SIM.
SLR.
SPC.
S.S.
STL.
T&B
THK.
T.O.F.
T.O.S.
T.O.W.
TYP.
U.N.O.
V.
VAR.
V.C.T.
VERT.
W.
W/
WD.
W.W.R

EXTERIOR LOAD-BEARING MASONRY WALLS

CONCRETE REINFORCING SPLICE LENGTH SCHEDULE

HOLLOW METAL
HORIZONTAL
HEATING / VENTILATION / AIR CONDITIONING
INSIDE FACE
INSULATION
INTERIOR
LENGTH
LONG LEG HORIZONTAL
LONG LEG VERTICAL
MAXIMUM
METAL
MANUFACTURER
MINIMUM
MISCELLANEOUS
NOT IN CONTRACT
NUMBER
ON CENTER
OUTSIDE FACE
PENNSYLVANIA DEPT. OF TRANSPORTATION
PLATE
POUNDS PER LINEAL FOOT
PAINT
POWDER
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
RADIUS
REQUIRED
REINFORCING
RETURN
SLIP CRITICAL
SECTION
SIMLAR
SEALER
SPACE
STAINLESS STEEL
STEEL
TOP AND BOTTOM
THICK
TOP OF FOOTING
TOP OF STEEL
TOP OF WALL
TYPICAL
UNLESS NOTED OTHERWISE
VINYL
VARIES
VINYL COMPOSITION TILE
VERTICAL
WIDE / WIDTH
WITH
WOOD
WELDED WIRE REINFORCING

4000 psi

WALL TYPE

3000 psi

REINF. SIZE

TOP HORIZ.
BARS (IN.)

VERTICAL (IN.)
OR BOTTOM HORIZ.

TOP HORIZ.
BARS (IN.)

#3

15

12

17

CLEAR OPENING

LINTEL
TYPE

SECTIONS

VERTICAL (IN.)
OR BOTTOM HORIZ.
5 1/2"

13
<6'-0"

#4

20

15

23

18

#5

25

19

28

22

#6

29

23

34

26

#7

43

33

49

38

16E1

2 SIDES
1/4

<10'-0"
49

37

56

2-6

PL 5/16"x13"
8" CMU
2" CAVITY
4" VENEER
5 1/2"

#8

L5x3 1/2x5/16
L.L.V.

1/2" DIA.x 4" LONG


HEADED STUDS
@ 2'-0" O.C.

ARCHITECTS

HSS8x4x3/16

16E2

43

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603
T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

2 SIDES
2-6

#9

60

46

69

53

#10

72

56

83

64

#11

85

66

98

76

NOTES:
1.
TOP HORIZONTAL BARS ARE DEFINED AS HORIZONTAL BARS WITH MORE
THAN 12" OF CONCRETE CAST IN THE MEMBER BELOW THE
REINFORCEMENT. BOTTOM HORIZONTAL BARS ARE ALL OTHER HORIZONTAL
BARS.
2.
FOR LIGHTWEIGHT AGGREGATE CONCRETE, MULTIPLY THE VALUES ABOVE
BY 1.3.
3.
FOR EPOXY COATED REINFORCEMENT WITH COVER LESS THAN 3db OR
CLEAR SPACING LESS THAN 6db, MULTIPLY VALUES ABOVE BY 1.5. FOR ALL
OTHER EPOXY COATED REINFORCEMENT, MULTIPLY THE VALUES ABOVE BY
1.3.
4.
ALL SPLICES ASSUMED TO BE CLASS B SPLICES.
5.
WHEN SPLICING BARS OF DIFFERENT SIZES, USE SPLICE LENGTH FOR
LARGEST BAR.
6.
MINIMUM HOOK LENGTH EQUALS 16db FOR NO. 3-8 BARS & 17db FOR NO. 9,
10, & 11 BARS.
7.
SPLICE LENGTHS GIVEN ARE MINIMUM, U.N.O.

12 * db
16db (FOR NO. 3-8 BAR)

PL 5/16"x13"

LINTEL NOTES:
1.
ALL LINTELS TO EXTEND 8" MIN. INTO SOLID OR GROUTED SUPPORTING MASONRY.
2.
ALL LINTELS WITH CLEAR OPENINGS GREATER THAN 6'-4" SHALL HAVE (2) 3/4" DIA. F1554 ANCHOR
BOLTS PER END (6" MIN. EMBED.) AT CONTRACTOR'S OPTION, BOLTS MAY BE REPLACED WITH (2)
5/8" DIA. EXPANSION ANCHOR BOLTS PER END (6" MIN. EMBED.)
3.
CONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS FOR ALL PENETRATIONS THROUGH
MASONRY WALLS. LINTEL SHALL BE PROVIDED FOR ALL OPENINGS GREATER THAN 12".
4.
ALL EXTERIOR WALL LINTELS SHALL BE GALVANIZED.
5.
PLATE WIDTH IS BASED ON SUPPORT OF 4" MASONRY VENEER. WHERE EXTERIOR VENEER TYPE
WIDTH VARIES, REDUCE OR INCREASE PLATE WIDTH AS REQ'D.

17db (FOR NO. 9-11 BAR)

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.

MASONRY REINFORCING SPLICE


LENGTH SCHEDULE

ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

REINF. SIZE

REVISIONS

VERT. OR HORIZ. (IN.)

NUMBER

AISC SHAPE DESIGNATION


INDICATES # OF SHEAR STUDS WELDED TO
TOP FLANGE OF BEAM PER GENERAL NOTES
BEAM CAMBER IN INCHES AT BEAM MIDSPAN
AXIAL PASS-THROUGH FORCE
XXK
0"
TYP.

XXK-FT

(X'-X")

INDICATES BRACED FRAME SEE ELEVATION

STEEL FRAMING REFERENCE

#5

45

#6

54

XXK (A)

ELEVATION OF TOP OF BEAM


MOMENT REACTION

36

INDICATES CONNECTION TO
BE DESIGN FOR AXIAL PASSTHROUGH FORCE

DATE

#7

DRAWN BY

63

#8

72

#9

81

2 1/2" (TYP.)
16db (FOR NO. 3-8 BAR)

2 1/2" (TYP.)

2" (TYP.)

2" (TYP.)

17db (FOR NO. 9-11 BAR)

TYP.

6"

TYP.

6"

TYP.

6"

TYP.

6"

- CONCRETE
"TEXT"

- PROPOSED CONDITIONS

"Text"

- EXISTING CONDITIONS
SIM

- SECTION MARK

S1

TYP. LINTEL BEARING DETAILS


1 1/2" = 1'-0"

NEW FACILITY FOR:

- MOMENT CONNECTION

4226.8.29.00

12 * db

- UN-REINFORCED MASONRY WALL


- REINFORCED MASONRY WALL

DHA

PROJECT NUMBER

NOTES:
1.
WHEN SPLICING BARS OF DIFFERENT SIZES
USE SPLICE LENGTH FOR LARGEST BAR.
2.
MINIMUM HOOK LENGTH EQUALS 16db FOR NO.
3-8 BARS & 17db FOR NO. 9,10&11 BARS.
3.
SPLICE LENGTHS GIVEN ARE MINIMUM, U.N.O.

GENERAL LEGEND

10/01/2014

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

TYPICAL SCHEDULES

WXxXX [XX ] c=3/4"

#4

REVISE BY

257 SOUTH 9TH STREET COLUMBIA, PA 17512

INDICATES MOMENT
CONNECTION

27

KLEEN-RITE CORPORATION

SHEAR REACTION

#3

DATE

S002

EXTERIOR STAIRS, GALVANIZE, W/ GRATING, TYP. (6) LOCATIONS W/ SONOTUBE FOUNDATIONS


1

1.5

2.5

3.5

4.5

5.5

6.5

7.5

8.5

400' - 0"
25' - 0"

POURED CONCRETE STAIRS

25' - 0"

25' - 0"

Sim

1
S203

WF1 (-2'-0")
WF2

W12X40
HSS12X12X5/16
CF5.5

CF5.5

25' - 0"

25' - 0"

Sim
STEP FTG.
DN. (-2'-0")

W12X40
CF12.5

1
S203

STEP FTG.
DN. (-2'-0")

Sim

25' - 0"

25' - 0"

STEP FTG.
DN. (-2'-0")

4
S203

W12X40
CF12.5
(
-8'
0"
)
WF3

WF3 ( -6' - 0" )

( -4' - 0" )

25' - 0"

Sim
HSS12X12X5/16
CF12.5

W12X40
CF8.0

5
S203

25' - 0"

25' - 0"

Sim

HSS12X12X5/16
CF8.0

W12X40
CF8.0

HSS12X12X5/16
CF8.0
D

W12X40
CF5.5

HSS12X12X5/16
CF12.5

HSS12X12X5/16
CF5.5

W12X40
CF8.0

W12X40
CF8.0

HSS12X12X5/16
CF8.0

HSS12X12X5/16
CF8.0
WF4 ( -10' - 0" )

HSS10X10X5/16
CF12.5

W12X40
CF8.0

WF1( -2' - 0" )

25' - 0"

5
S203

HSS10X10X5/16
CF8.0

HSS10X10X5/16
CF8.0

HSS10X10X5/16
CF8.0

HSS10X10X5/16
CF8.0

HSS10X10X5/16
CF8.0

HSS10X10X5/16
CF8.0

HSS10X10X5/16
CF8.0

5
S402

WF5 ( -12' - 0" )

HSS10X10X5/16
CF8.0

HSS10X10X5/16
CF8.0

8" CMU ELEVATOR


SHAFT, GROUTED
SOLID

HSS10X10X5/16
CF10.0

HSS10X10X5/16
CF10.0

ELEVATOR FOUNDATION,
12" THK. REINFORCED W/
#5 BARS E.W., BOT.

9' - 11 1/4"

HSS12X12X3/8
CF13.5

HSS10X10X5/16
CF10.0

( -4' - 0" )

8' - 2 1/4"

WF3

HSS12X12X5/16
CF5.5

A.7

HSS10X10X5/16
CF10.0
W12X40
CF5.5
WF3 ( -8' - 0" )

HSS10X10X5/16
CF10.0

WF2
( -4' - 0" )

HSS10X10X5/16
CF8.0

DOCK LEVELER PITS TO BE


7'-3"x6'-1". CONFIRM SIZE W/
DOCK LEVELER MFR.

1' - 0" TYP.

HSS12X12X5/16
CF13.5

HSS12X12X5/16
CF13.5
W12X40
CF12.5

HSS12X12X5/16
CF13.5
W12X40
CF8.0

39' - 0 7/8"

HSS12X12X5/16
CF11.0

A.5

B.5

WF4 ( -10' - 0" )

W12X40
CF5.5

STEP FTG.
DN. (-2'-0")

W12X40
CF8.0

2
S402

WF2
( -2' - 0" )

STEP FTG.
DN. (-2'-0")

14' - 0 7/8" 10' - 11 1/8"

25' - 0"

WF1 (-2'-0")

B.5

25' - 0"

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603

HSS12X12X5/16
CF8.0

HSS10X10X5/16
CF12.5

W12X40
CF5.5

A.1

C.5

WF5 ( -13' - 0" )

25' - 0"

2
S203

ARCHITECTS

T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

HSS12X12X5/16
CF11.0

25' - 0"

25' - 0"

WF5 ( -12' - 0" )

C.5

150' - 0"

3
S203

STEP FTG.
DN. (-2'-0")

W12X40
CF5.5

25' - 0"

( -2' - 0" )

HSS12X12X5/16
CF5.5

P1

WF2

25' - 0"

100' - 0"

25' - 0"

2
S203

WF1 ( -2' - 0" )

25' - 0"

STEP FTG.
DN. (-2'-0")

24 x 24

A.7

25' - 0"

STEP FTG.
DN. (-1'-0")

25' - 0"

W12X40
CF8.0

HSS12X12X5/16
CF13.5

( -8' - 0" )

HSS12X12X5/16
CF8.0
HSS12X12X5/16
CF8.0

W12X40
Sim
CF8.0
3
S203

W12X40
CF8.0
STEP FTG.
DN. (-2'-0")

HSS12X12X5/16
CF12.5
STEP FTG.
DN. (-2'-0")

4
S203

W12X40
CF12.5

HSS12X12X5/16
CF8.0
Sim

5
S203

W12X40
CF8.0

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.

STEP FTG.
DN. (-1'-0")

175' - 0"
A.5

ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

5.5

6.5

7.5

8.5

REVISIONS
NUMBER

DATE

REVISE BY

A.1

A
WF3

( -6' - 0" )

3
S203
18' - 5"

31' - 7"

19' - 0"

31' - 0"

19' - 0"

31' - 0"

19' - 0"

27' - 2"

STEP FTG.
DN. (-2'-0")

HSS12X12X5/16
CF5.5

3' - 10"

200' - 0"

DATE

10/01/2014

DRAWN BY

DHA
4226.8.29.00

PROJECT NUMBER

A.6

2.3

3.3

4.3

4.9

GENERTAOR. REFER
TO ARCH. & ELEC.
PLANS FOR LOCATION

FOUNDATION PLAN

HEIGHT
VARIES

REINFORCING
(8) #8 BARS VERT., #3 TIES @ 12"

COLUMN FOOTING SCHEDULE

MARK
CF5.5
CF8.0
CF10.0
CF11.0
CF12.5
CF13.5

WIDTH
5' - 6"
8' - 0"
10' - 0"
11' - 0"
12' - 6"
13' - 6"

DIMENSIONS
LENGTH
5' - 6"
8' - 0"
10' - 0"
11' - 0"
12' - 6"
13' - 6"

DEPTH
1' - 2"
1' - 6"
2' - 0"
2' - 0"
2' - 6"
2' - 6"

REINFORCING
5-#6 EACH DIRECTION BOTTOM
9-#5 EACH DIRECTION BOTTOM
10-#6 EACH DIRECTION BOTTOM
10-#6 EACH DIRECTION BOTTOM
11-#7 EACH DIRECTION BOTTOM
13-#7 EACH DIRECTION BOTTOM

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

FOUNDATION PLAN

TYPE
24 x 24

257 SOUTH 9TH STREET COLUMBIA, PA 17512

MARK
P1

NEW FACILITY FOR:

PIER SCHEDULE

FOUNDATION PLAN NOTES:


1.
FINISHED FIRST FLOOR ELEV.= 330.00 (0'-0"), U.N.O.
2.
ALL ELEVATIONS NOTED THUS (-X'-X") DESIGNATE TOP OF FOOTING OR PIER ELEVATIONS AND ARE WITH RESPECT TO THE FINISHED FIRST FLOOR ELEVATION.
3.
TOP OF INTERIOR FOOTING ELEVATION IS (-1'-0") BELOW FINISHED FIRST FLOOR ELEVATION, U.N.O.
4.
TOP OF EXTERIOR FOOTING ELEVATION IS (-2'-8") BELOW FINISHED FIRST FLOOR ELEVATION, U.N.O.
5.
TOP OF PIER ELEVATION IS (-0'-8") BELOW FINISHED FLOOR ELEVATION, U.N.O. ALL PIERS TO BE P1, U.N.O.
6.
ALL INTERIOR NON-LOAD BEARING WALLS MAY BEAR ON THICKENED SLAB, U.N.O.
7.
ALL COLUMNS TO CENTER ON FOOTINGS AND PIERS, U.N.O. ALL WALLS TO CENTER ON WALL FOUNDATIONS, U.N.O.
8.
ALL INTERIOR FLOOR SLABS SHALL BE 7" THK. NON-AIR ENTRAINED REINFORCED WITH #3 BARS @ 15" O.C. E.W. (OR EQUIVALENT W.W.R.) ON 6" OF PennDOT 2A COMPACTED STONE,
U.N.O. PROVIDE SAWCUT CONTROL JOINTS AS INDICATED IN THE CAST-IN-PLACE CONCRETE CONSTRUCTION SECTION OF THE GENERAL SPECIFICATIONS. SUBMIT A CONTROL JOINT
LOCATION PLAN TO THE ENGINEER FOR REVIEW AND APPROVAL.
9.
ALL EXTERIOR CONCRETE SLABS SHALL BE 5" THK. AIR ENTRAINED CONCRETE W/6x6 W2.9xW2.9 W.W.R. ON 6" PennDOT 2A COMPACTED STONE, U.N.O. ALL EXTERIOR SLABS SHALL BE
TURNED DOWN AROUND PERIMETER AND EXTEND TO (-3'-0") BELOW FINISHED GRADE. SEE SLAB TURNDOWN DETAIL, SHEET S201.
10.
MASONRY WALLS SHALL BE REINFORCED W/ #5 @ 48" O.C. WHERE REINFORCING IS SHOWN, U.N.O. PROVIDE CONTROL JOINTS IN CMU WALLS AS INDICATED IN THE CONCRETE MASONRY
CONSTRUCTION SECTION OF THE GENERAL SPECIFICATIONS, U.N.O. SUBMIT A CONTROL JOINT LOCATION PLAN TO THE ENGINEER FOR REVIEW AND APPROVAL.
11.
CONCRETE WALLS SHALL BE REINFORCED W/ #5 @ 18" O.C. VERT. & #4 @ 12" O.C. HORIZ., U.N.O. PROVIDE VERTICAL CONTROL JOINTS IN CONCRETE WALLS AS INDICATED IN THE CAST
IN-PLACE CONCRETE CONSTRUCTION SECTION OF THE GENERAL SPECIFICATIONS, U.N.O. SUBMIT A CONTROL JOINT LOCATION PLAN TO THE ENGINEER FOR REVIEW AND APPROVAL.
12.
SEE FOOTING, COLUMN & BASE PLATE, PIER AND WALL FOOTING SCHEDULES, THIS SHEET.
13.
SEE ARCHITECTURAL DRAWINGS FOR ALL NECESSARY EMBEDDED ITEMS, RAMPS, STAIRS, LANDINGS, AND FINISH DETAILS.
14.
SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND ELEVATIONS NOT SHOWN.
15.
CONTRACTOR SHALL VERIFY WALL LOCATIONS WITH ARCHITECTURAL PLANS PRIOR TO FOUNDATION LAYOUT. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION
OF THE ARCHITECT AND ENGINEER.
16.
FOUNDATIONS AND FRAMING ARE BASED ON BASE BID WALL SYSTEM, SEE ARCHITECTURAL PLANS.
17.
SEE WALL FOOTING SECTIONS ON SHEET S203 FOR SIZE AND REINFORCING OF ALL WALL FOOTINGS CALLED OUT ON PLAN.

KLEEN-RITE CORPORATION

1/16" = 1'-0"

S101

200' - 0"
50' - 0"

50' - 0"

50' - 0"

ARCHITECTS

10' - 11 1/8"

50' - 0"

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603
T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

28LH09 @ 3'-0" O.C. MAX.

( 16' - 3" )

W27X217

( 16' - 3" )

W27X217 ( 16' - 3" )

12
6

A.1
1/2" DIA. x4" LONG
HEADED STUDS @
2'-0" O.C.

2' - 5"

HSS8x4x3/16
31' - 7"

19' - 0"

31' - 0"

19' - 0"

31' - 0"

19' - 0"

3' - 10"

27' - 2"

600 S200-54
(50KSI)
STUDS @ 24"
O.C., TYP.

2 SIDES
1/4

2-6

200' - 0"

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.

PL. 5/16"x7"
2

2.3

3.3

4.3

4.9

ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

MEZZANINE FRAMING PLAN

DOCK DOOR CANOPY DETAIL

1/16" = 1'-0"

3/4" = 1'-0"

REVISIONS
NUMBER

MEZZANINE FRAMING PLAN NOTES:


1.
FINISHED FLOOR ELEVATION = 350.00 (+17'-0").
2.
TOP OF STEEL BEAM OR JOIST GIRDER = 349.67 (+16'-8"), U.N.O.
3.
ALL ELEVATIONS NOTED THUS (+X'-X") REFERENCED TO FINISHED FIRST FLOOR ELEVATION.
4.
FLOOR SLAB SHALL BE 4" THK. CONCRETE REINFORCED W/ 6x6 - W1.4 x W1.4 ON 1.5VL20 DECK W/ 5/8" DIA. PUDDLE
WELDS IN 36/4 FASTENER PATTERN AT ALL SUPPORTS W/ #10 SIDELAP SCREWS @ 12" O.C. U.N.O. WHERE SHEAR
STUDS OCCUR, THE STUD WELD MAY REPLACE A DECK PUDDLE WELD.
5.
PROVIDE AN L4x4x1/4 AT ALL FLOOR EDGES, TYPICAL, U.N.O.
6.
BRACE MASONRY WALLS UNTIL METAL DECK HAS BEEN INSTALLED AND CONCRETE FLOOR HAS BEEN POURED.
7.
ALL ANGLE TO MASONRY WALL CONNECTIONS ARE 5/8" DIA. EXPANSION BOLTS @ 24" O.C., MIN. 4" EMBED. IN GROUTED
CORES U.N.O.
8.
SEE FOUNDATION PLAN FOR ALL WALL REINFORCING SIZE & SPACING, U.N.O.
9.
SEE ARCHITECTURAL DRAWINGS FOR ALL NECESSARY EMBEDDED ITEMS, RAMPS, STAIRS, LANDINGS, AND FINISH
DETAILS.
10.
SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND ELEVATIONS NOT SHOWN.
11.
JOIST BRIDGING SHALL BE DESIGNED AND PROVIDED BY JOIST MANUFACTURER IN ACCORDANCE WITH THE STEEL
JOISTS INSTITUTES (SJI) REQUIREMENTS.

DATE

REVISE BY

DATE

10/01/2014

DRAWN BY

DHA
4226.8.29.00

PROJECT NUMBER

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

MEZZANINE FRAMING PLAN

A.6

NEW FACILITY FOR:

257 SOUTH 9TH STREET COLUMBIA, PA 17512

18' - 5"

(5) #12 TEK SCREWS, TYP.

KLEEN-RITE CORPORATION

A.7

A.5

W27X84 ( 16' - 8" )

W30X99

( 16' - 8" )

W27X217

( 16' - 3" )

W27X84 ( 16' - 8" )

( 16' - 3" )

28LH09 @ 3'-0" O.C. MAX.

W30X99

( 16' - 8" )

W30X99

W27X84 ( 16' - 8" )

39' - 0 7/8"

( 16' - 3" )

28LH09 @ 3'-0" O.C. MAX.

W27X217

W27X217

W27X84 ( 16' - 8" )

( 16' - 3" )

28LH09 @ 3'-0" O.C. MAX.

A.1

W27X217

W27X217

( 16' - 3" )

14' - 0 7/8"
22' - 7"

50' - 0"

STAIRS BY
STAIR MFR.

( 16' - 8" )

STAIRS BY
STAIR MFR.
W27X217

A.7

A.5

AL600 STIFF CLIP W/ (4) #12 TEK


SCREWS TO STUD & (2) 1/4" DIA.
HILTI HUS-EZ (KH-EZ) TO CMU W/
MIN. 3" EMBED INTO GROUTED
CMU FACE SHELL, TYP.

S102

S401
2

1.5

25' - 0"

25' - 0"

2.5

25' - 0"

25' - 0"

( 34' - 1 1/2" )

3.5

25' - 0"

25' - 0"

W27X84

4.5

25' - 0"

25' - 0"

25' - 0"

( 34' - 1 1/2" )

W27X84

5.5

25' - 0"

25' - 0"

25' - 0"

( 34' - 1 1/2" )

W27X84

7.5

25' - 0"

( 34' - 1 1/2" )

W27X84

6.5

25' - 0"

25' - 0"

25' - 0"

( 34' - 1 1/2" )

( 34' - 1 1/2" )

W27X84

8.5

W27X84

ARCHITECTS

W27X84

30K11 @ 6'-3" O.C.

ROOF SLOPE 1/4" PER 1'-0"


48G8N16K

48G8N16K

BRACING
ELEV @ COL.
LINE 1

W16X31

48G8N16K

48G8N16K

48G8N16K

JOIST BEARING = +33'-1"


C

B.5

W16X31

25' - 0"

W16X31

S401

BRACING
ELEV @ COL.
LINE 5

25' - 0"

48G8N16K

C.5

30K11 @ 6'-3" O.C.

150' - 0"

S401

48G8N16K

T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

100' - 0"

48G8N16K

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603

ROOF SLOPE 1/4" PER 1'-0"

25' - 0"

W16X31

C.5

B.5

BRACING
ELEV @ COL.
LINE D

25' - 0"

( 34' - 1 1/2" )

( 34' - 1 1/2" )

W27X84

PROVIDE A 1" MIN. BUILDING EXPANSION


JOINT ALONG COLUMN LINE 5. PROVIDE
TEFLON COATED PLATES TO ALLOW FOR
MOVEMENT AT BEAMS/JOIST GIRDER TO
COLUMN CONNECTIONS

FULL HEIGHT HSS4-1/2xHSS4-1/2x1/4


CROSS BRACING, TYP., (10) LOCATIONS
JOIST BEARING = +32'-0 1/2"

48G8N16K

48G8N16K

48G8N16K

W30X108

W30X108
( 32' - 0 1/2" )

25' - 0"

W30X108

( 32' - 0 1/2" )

BRACING
ELEV @ COL.
LINE B

A.7

W30X108

( 32' - 0 1/2" )

( 32' - 0 1/2" )

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.

ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

S401

30K11 @ 6'-3" O.C.

REVISIONS

175' - 0"

39' - 0 7/8"

W16X31

25' - 0"

W16X31

A.5

A.1

NUMBER

W27X84 ( 31' - 0" )

W27X84 ( 31' - 0" )

W27X84 ( 31' - 0" )

W27X84 ( 31' - 0" )

REVISE BY

A.5
5.5

6.5

A.1

DATE

7.5

8.5

ROOF JOISTS TO BE DESIGNED FOR A SNOW DRIFT @ THE


PARAPET AROUND THE PERIMETER OF THE BUILDING. (42
PSF TAPPERING TO 0 PSF OVER 20'-0", THIS IS IN ADDITION
TO THE 30 PSF FLAT ROOF SNOW LOAD)

A
DATE

10/01/2014

DRAWN BY

DHA
4226.8.29.00

PROJECT NUMBER

50' - 0"

50' - 0"

50' - 0"

50' - 0"

200' - 0"
BRACING
ELEV @ COL. 2.3
LINE A

3.3

4.3

4.9

4
S401

ROOF FRAMING PLAN


1/16" = 1'-0"

ROOF FRAMING PLAN NOTES:


1.
ALL ELEVATIONS NOTED THUS (+X'-X") REFERENCED TO FINISHED FIRST FLOOR ELEVATION.
2.
JOIST BEARING ELEVATION VARIES. SLOPE MASONRY WALLS AND BEAMS ACCORDINGLY, WHERE REQUIRED, FOR BEARING ELEVATIONS.
3.
JOIST BRIDGING SHALL BE DESIGNED AND PROVIDED BY JOIST MANUFACTURER IN ACCORDANCE WITH THE STEEL JOIST INSTITUTES (SJI)
REQUIREMENTS.
4.
ROOF DECK SHALL BE 1.5B22 DECK FASTENED TO SUPPORTS W/ 5/8" DIA. PUDDLE WELDS IN 36/4 FASTENER PATTERN W/ #10 SIDELAP SCREWS @
12" O.C. BETWEEN SUPPORTS, U.N.O.
5.
ALL ROOF PENETRATION LOCATIONS ARE APPROXIMATE. COORDINATE W/ HVAC CONTRACTOR FOR EXACT LOCATIONS. PROVIDE FRAMING FOR ALL
ROOF PENETRATIONS AS SHOWN IN THE TYPICAL ROOF PENETRATION FRAMING DETAIL.
6.
DETAILS AS SHOWN INDICATE TYPICAL CONNECTIONS AND CONDITIONS.
7.
SEE ARCHITECTURAL PLANS FOR TOP OF NON-LOAD BEARING WALL HEIGHTS AND ROOF SLOPES.
8.
SEE ARCHITECTURAL AND HVAC PLANS FOR EXACT LOCATIONS OF ROOF TOP UNITS, ROOF DRAINS, AND ROOF VENTS.
9.
SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND ELEVATIONS NOT SHOWN.

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

ROOF FRAMING PLAN

257 SOUTH 9TH STREET COLUMBIA, PA 17512

A.6

NEW FACILITY FOR:

KLEEN-RITE CORPORATION

A.7

48G8N16K

S103

SEE
6' PLAN
- 3"
L3x3x1/4, CONT., TYP. ALL
EDGES, U.N.O. W/ 1/2" DIA. x
6" HEADED STUDS @ 12" O.C.
SEE PLAN FOR
SLAB THICKNESS
AND REINF.

1' - 7 1/2"

1' - 8"

FACE OF WALL
BEYOND

8"

ROUGHENED
CONSTRUCTION
JOINT, TYP.

8" THK. SLAB W/ #5 @


12" O.C., E.W.,
CENTERED IN SLAB

1/2" SLOPE

8" TYP.
SEE PLAN FOR WALL THICKNESS AND REINF.
ARCHITECTS

SUMP PIT W/ COVER - COORDINATE FINAL SIZE, LOCATION,


& DETAILS W/ ELEVATOR MFR. & PLUMBING CONTRACTOR
SEE PLAN FOR FOOTING SIZE AND REINF.

8" THK. CONC. WALL

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603
T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

#5 @ 12" O.C., TYP.

TEMPORARILY SHORE WALL


UNTIL FLOOR SLAB IS
PLACED AND HAS REACHED
ITS DESIGN STRENGTH

3' - 0"

1' - 0"

(3) #5 BARS, CONT.

NOTES:
1.
SEE ARCHITECTURAL PLANS FOR EXACT SIZE & LOCATION
OF DOCK LEVELER.
2.
COORDINATE ALL LEVELER DIMENSIONS WITH
MANUFACTURER.
3.
SEE ARCHITECTURAL PLANS FOR BUMPERS & HARDWARE,
& COORDINATE DETAILS WITH MANUFACTURER.

1
1 1/2
LAP SPLICE
1' - 0"

THICKNESS "T"

#5 BAR @ 12" O.C. MAX.

SEE TABLE

WALL FOOTING

#4 BAR @ 12" O.C. MAX.

"T"

SEE PLAN

#5 BAR @ 18" O.C. MAX.

STANDARD HOOK

STEP
- 0"
1' HEIGHT

L4x4x1/4 W/ 1/2" DIA. x 6"


HEADED STUDS @ 12" O.C.

SUMP PIT DEPTH

2'-0"

SUMP PIT DEPTH

#5 BAR @ 12" O.C.


TYP. ALL JOINTS

1' - 0"

2'-0"

SEE TABLE

MIN.

#5 @ 12" O.C., TYP.

DOCK LEVELER DETAIL

ELEVATOR SUMP PIT DETAIL

STEP FOOTING DETAIL

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.
ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

REVISIONS
NUMBER

WALL BEYOND

12" HOOK
FINISH GRADE

SEE ARCH. PLANS


FOR DOOR &
WINDOW SCHEDULE

12" HOOK, TYP.

SLOPE 1/4"/FT.

TOOLED
EDGE
DATE

10/01/2014

DRAWN BY

8"

6" MIN.

DHA
4226.8.29.00

PROJECT NUMBER

OPTIONAL
CONST.
JOINT

1/2" ISOLATION
JOINT MATERIAL
#4 @ 12" O.C.

SEE WALL FTG.


SCHEDULE FOR
SIZE AND REINF.
NOTE:
SEE CIVIL & ARCH. PLANS FOR
SIZE AND LOCATION OF LANDINGS

SLAB TURNDOWN

TYPICAL SECTION AT EXTERIOR DOOR LANDINGS

1" = 1'-0"

1" = 1'-0"

NEW FACILITY FOR:

8"

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

257 SOUTH 9TH STREET COLUMBIA, PA 17512

#4 BAR @ 12" O.C., TYP.

KLEEN-RITE CORPORATION

#4 BAR @ 24"
O.C. GROUT
SOLID

8" TYP.
AROUND PERIMETER
OF LANDING

3'-0" MIN.

3' - 0" MIN.

OPTIONAL
CONSTRUCTION
JOINT

REVISE BY

FOUNDATION DETAILS

TOOLED EDGE

DATE

S201

CL. COL. & FOOTING

CL. COL. & FOOTING

1/4" LEV. PLATE

FOUNDATION PLAN

7"
EQ.

7"
EQ.

EQ.
7"

(4) 3/4" DIA. ASTM


(F1554) HEADED
ANCHOR BOLTS MIN.
12" EMBED. (9" FOR 1'0" THK. FTGS.)

3"

EQ.
7"

1 1/2" TYP.

CL. COL.
1/4

NOTES:
1.
DOWELS SHOULD BE PLAIN ROUND ASTM A615
GRADE 60.
2.
PLACE DOWELS LEVEL AND PARALLEL TO DIRECTION
OF SLAB MOVEMENT. PROVIDE SUPPORT FOR
DOWELS DURING CONSTRUCTION.

CL. COL.
1/4

INTERIOR WIDE FLANGE COLUMN BASE

HSS TUBE COLUMN BASE PLATE

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

3/4" CHAMFER, TYP.

1" CLR.
2' - 0"

JOINT SEALANT, TYP.


SIKAFLEX 1A

DOWELED CONSTRUCTION JOINT


1" = 1'-0"

1/8" WIDE
SAWCUT JOINT

1' - 0"

8"
STD. 90

CUT ALT. BARS IN E.F. AT


CONSTRUCTION JOINT

DEG. HOOK

NOTE:
SEE ARCHITECTURAL PLANS FOR
EXACT STAIR CONFIGURATION.

NOTES:
1.
DOWELS SHOULD BE PLAIN ROUND ASTM A615 GRADE 60.
2.
PLACE DOWELS LEVEL AND PARALLEL TO DIRECTION OF
SLAB MOVEMENT. PROVIDE SUPPORT FOR DOWELS
DURING CONSTRUCTION.
3.
SLABS WITH W.W.R., SAWCUT CONTROL JOINT SHALL BE
1/4" t DEEP.

NOTES:
1.
CUT ALTERNATING BARS IN E.F. AT CONTROL
JOINT.
2.
PROVIDE CONTROL JOINTS AS INDICATED IN PLAN
AND IN THE CAST-IN-PLACE CONSTRUCTION
SECTION OF THE GENERAL SPECIFICATIONS.

NOTE:
1.
REFER TO WALL SECTION FOR ORIENTATION
OF REINFORCEMENT.
2.
SEE REINF. SPLICE LENGTH SCHEDULE FOR
SPLICING LENGTHS.

8"

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.
ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

REVISIONS
NUMBER

TYP. PIER DETAIL

CONCRETE STAIR REINFORCING

CONCRETE WALL CORNER

CONCRETE WALL CONTROL JOINT

DOWELED SAWCUT CONTROL JOINT

1" = 1'-0"

1" = 1'-0"

3/4" = 1'-0"

1" = 1'-0"

1" = 1'-0"

REVISE BY

.
AX
M
6"

10/01/2014

DRAWN BY

DHA
4226.8.29.00

(3) #3 TIES OR
(2) #4 TIES
WITHIN FIRST
FIVE (5) INCHES
OF TOP OF
PIER

WHERE ISOLATION
JOINTS DO NOT HAVE
A CONTROL JOINT ON
CORNER, PROVIDE
(2) #4 BARS x 2'-6"
LONG IN SLAB

OPTIONAL
ISOLATION JOINT
CONFIGURATION
JOINT SEALER, TYP.

TOP OF
FOOTING,
GRADE BEAM
OR CAISSON

ISOLATION JOINT,
1/4" PREM. JOINT
FILLER & SEALANT
COLUMN BASE PLATE

CONTROL
JOINT FILLER
(WATERSTOP)

HORIZONTAL
REINFORCING
(CUT 1/2 @
CONTROL JOINT)

NOTES:
1. POUR CONCRETE WITHIN ISOLATION JOINT DOWN TO TOP OF PIER.
2. ISOLATION JOINT SIMILAR @ PERIMETER COLUMNS.
3. IF CONTRACTOR PREFERS A DIFFERENT ISOLATION JOINT DETAIL, PLEASE
SUBMIT DETAIL TO ENGINEER FOR REVIEW.

CONCRETE FLOOR SLAB/WALL


PIPE PENETRATION
REINFORCEMENT DETAIL

TYPICAL PIER TIE REINFORCING DETAIL

SLAB ISOLATION JOINT AT COLUMN DETAIL

MASONRY WALL CONTROL JOINT

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

NEW FACILITY FOR:

1/2"
CONTROL
JOINT

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

257 SOUTH 9TH STREET COLUMBIA, PA 17512

4" MAX.

2" CLR.

IN PIER SCHEDULE

.
YP
.T
LR
C
6"

NOTES:
1.
REINFORCING SHOWN IS IN ADDITION TO ANY
REINFORCING INDICATED FOR THE WALL OR FLOOR SLAB.
2.
THIS DETAIL APPLIES TO ALL OPENINGS IN WALLS OR
FLOOR SLABS UP TO 6" IN SIZE (SQUARE OR DIA.).
3.
PROVIDE HALF OF THE INTERRUPTED BARS (HORIZONTAL
& VERTICAL) ON EACH SIDE OF THE OPENING, WITH THE
BARS EXTENDING A FULL SPLICE LENGTH PLUS 3"
BEYOND BOTH SIDES OF THE OPENING.

TIE SPCG. AS INDICATED

1 1/2"
CLR.

TY
P.

4"

CONTROL JOINTS ON
COLUMN CENTERLINE

KLEEN-RITE CORPORATION

.
YP
.T
LR
C
6"

PROJECT NUMBER

VARIES
1' - 0"

.
YP
.T
LR
C
6"

DATE

2" CLR.
#5 E.F., TYP.

DATE

FOUNDATION DETAILS

1' - 0"

CL. PIER

2' - 0"

T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

SLAB JOINT SEALANT


PER SPECIFICATIONS

#6 SMOOTH BAR DOWEL,


(GRADE 60) x 16" @ 24"
O.C., GREASE ONE SIDE
TO ENSURE MOVEMENT

(8) #8'S VERT.

#3 TIES @ 16"

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603

1/3 t

#4 NOSING BAR, TYP.

4" PVC WATERSTOP

LAP SPLICE

INDUCED CRACK

1' - 0"

TOOLED EDGE

ARCHITECTS

INTERIOR HSS COLUMN BASE

1' - 0"

#6 SMOOTH BAR
DOWEL (GRADE 60)
x 16" @ 12" O.C.,
GREASE ONE SIDE TO
ENSURE MOVEMENT

CL. COL.

WIDE FLANGE COLUMN BASE


PLATE

CL. PIER

SLAB JOINT SEALANT


PER SPECIFICATIONS

EQ.
7"

CL. COL.

ASTM (F1554) HEADED


ANCHOR BOLTS (SEE
SCHEDULE FOR SIZE).
MIN. 12" EMBED. (9" FOR
1'-0" THK. FTGS.)

BASE PLATE TO BE
18"x18"x3/4" THK.

1 1/2" TYP.
(4) 3/4" DIA. ASTM
(F1554) HEADED
ANCHOR BOLTS MIN.
12" EMBED. (9" FOR 1'0" THK. FTGS.)

EQ.
7"

SEE

3/4" GROUT

TOP OF CONC. PIER


OR FOOTING
NOTE:
SEE COLUMN & BASE PLATE SCHEDULE
FOR LOCATIONS.

7"
EQ.

3"

1 1/2" TYP.

ASTM (F1554) HEADED


ANCHOR BOLTS (SEE
SCHEDULE FOR SIZE).
MIN. 12" EMBED. (9" FOR
1'-0" THK. FTGS.)

BASE PLATE
THICKNESS TO BE
3/4"

1 1/2" TYP.

1/2" ISOLATION JOINT MATERIAL

TOP OF CONC. PIER


OR FOOTING
NOTE:
SEE COLUMN & BASE PLATE SCHEDULE
FOR LOCATIONS.

7"
EQ.

1/2" ISOLATION JOINT MATERIAL

N
FINISHED
FLOOR

1' - 0"

SEE

FINISHED
FLOOR

FOUNDATION PLAN

1/4" LEV. PLATE

CONC. SLAB

1' - 0"

3/4" GROUT

CONC. SLAB

S202

VENEER. SEE ARCH. PLANS

3' - 0" MAX.

4 5/8"

ISOLATION JOINT
MATERIAL

VENEER. SEE ARCH. PLANS

SEE FOUNDATION PLAN


FOR SIZE & REINF.

#4 BAR @ 12" O.C.


2'-0"
2'-0"

FOUNDATION PLAN
333' - 0"

1' - 3 5/8"

ARCHITECTS

HILTI HY 150 MAX EPOXY ADHESIVE


W/ MIN. 6" EMBED. & 4" PROJECTION,
TYP. SPACING TO MATCH CMU
REINF. SPACING. INSTALL IN SAME
CMU CORE AS CMU REINF.

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603
T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

#5 BARS @ 16" O.C.


EXTERIOR GRADE

ISOLATION JOINT
MATERIAL

FOUNDATION PLAN
333' - 0"

1' - 0"

EXTERIOR GRADE ELEV. = 336'-0" MAX.

1' - 3 5/8"
#5 BAR @ 18" O.C.
1' - 0"
TEMPORARILY SHORE WALL
UNTIL FLOOR SLAB IS
PLACED AND HAS REACHED
ITS DESIGN STRENGTH

EXTERIOR GRADE

2' - 0"

5' - 0"

2' - 0"

1' - 6"

#5 BAR @ 18" O.C.

1' - 0"

(3) #5 BARS CONT.

1' - 0"

1' - 0"

#5 BARS @ 48" O.C.,


CENTERED IN 8"
WALL ABOVE

#4 BAR @ 12" O.C.

#4 BAR @ 12" O.C.


3'-0"
2'-0"

2' - 6"

2' - 0"

2' - 0"

8'-0" MAX.

FOUNDATION PLAN
333' - 0"

(3) #5 BARS CONT.

7' - 6"
#5 BARS @ 24" O.C.
3' - 0"

1
S203

#5 BAR @ 18" O.C.

#5 BARS @ 24" O.C.


3' - 0"

SECTION - WF1

1" = 1'-0"

S203

ROUGHENED CONSTRUCTION JOINT


This document and information herein are the
property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.

#4 BAR @ 12" O.C.

SECTION - WF2

1" = 1'-0"

S203

SECTION - WF3
1/2" = 1'-0"

ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

REVISIONS
NUMBER

DATE

REVISE BY

SEE FOUNDATION PLAN


FOR SIZE & REINF.
DATE

HILTI HY 150 MAX EPOXY ADHESIVE


W/ MIN. 6" EMBED. & 4" PROJECTION,
TYP. SPACING TO MATCH CMU
REINF. SPACING. INSTALL IN SAME
CMU CORE AS CMU REINF.

DRAWN BY

DHA
4226.8.29.00

PROJECT NUMBER

FOUNDATION PLAN
333' - 0"

1' - 0"

10/01/2014

SEE FOUNDATION PLAN


FOR SIZE & REINF.
HILTI HY 150 MAX EPOXY ADHESIVE
W/ MIN. 6" EMBED. & 4" PROJECTION,
TYP. SPACING TO MATCH CMU
REINF. SPACING. INSTALL IN SAME
CMU CORE AS CMU REINF.

TEMPORARILY SHORE WALL


UNTIL FLOOR SLAB IS
PLACED AND HAS REACHED
ITS DESIGN STRENGTH

MAX.

1' - 0"

TEMPORARILY SHORE WALL


UNTIL FLOOR SLAB IS
PLACED AND HAS REACHED
ITS DESIGN STRENGTH

#5 BAR @ 18" O.C.

#5 BAR @ 18" O.C.

EXTERIOR GRADE
EXTERIOR GRADE

2' - 0"

NEW FACILITY FOR:

#5 BAR @ 18" O.C.

2' - 0"

2' - 0"

13' - 0"

1' - 6"

1' - 6"

10' - 6"

2' - 0"

2' - 6"

#5 BAR @ 18" O.C.

2' - 6"

1' - 9"
#5 BAR @ 9" O.C.

1' - 6"

#5 BAR @ 12" O.C.

WALL FOOTING SECTIONS

MAX.

10' - 0"

#4 BAR @ 12" O.C.


3'-0"
2'-0"

8' - 0" MAX.

#4 BAR @ 12" O.C.

13' - 0"

1' - 6"

257 SOUTH 9TH STREET COLUMBIA, PA 17512

#4 BAR @ 12" O.C.


3'-0"
2'-0"

KLEEN-RITE CORPORATION

#4 BAR @ 12" O.C.

11' - 0" MAX.

1' - 0"

FOUNDATION PLAN
333' - 0"

16' - 3"
13' - 0"
#4 BAR @ 12" O.C.
#4 BAR @ 12" O.C.

4
S203

ROUGHENED CONSTRUCTION JOINT

ROUGHENED CONSTRUCTION JOINT

SECTION - WF4
1/2" = 1'-0"

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

5
S203

SECTION - WF5
1/2" = 1'-0"

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

S203

JOIST GIRDER, SEE


PLAN FOR SIZE

(2) 3/4" DIA. BOLTS, TYP.

L5x3 1/2x1/2, L.L.V.


JOIST GIRDER, SEE
PLAN FOR SIZE
1/2" CLR.
1" MIN. (K SERIES)
2" MIN. (LH/DLH
-SERIES)

JOIST GIRDER, SEE


PLAN FOR SIZE

JOIST AT OR NEAREST
TO THE COLUMN SHALL
BE BOLTED

1/2" CLR.

3/4" THK. PLATES


1" THK.
CAP PLATE

1/2" CLR.

(2) 3/4" DIA. BOLTS, TYP.

(2) 3/4" DIA. BOLTS, TYP.


1" THK.
CAP PLATE

1' - 0"
6"

1 1/2"

ARCHITECTS

4"

3/4" THK. STABILIZER


PLATE, TYP.

3"

43.
43

JOIST
GIRDER

3/4" THK.
STABILIZER
PL., TYP.

3/4" THK.
STABILIZER PL.

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603
T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

TYP.
5/16
NO WELD, TYP.
*ENGINEER'S NOTE*
STIFFENED SEAT
CONNECTION
CAPACITY = 70K

3/16

NO WELD, TYP.
NO WELD, TYP.

L2x2x1/4 BOT. CHORD BRACE AS REQ'D BY JOIST GIRDER


SUPPLIER TO LIMIT L/R TO 240 OR FOR UPLIFT AS REQUIRED

JOIST GIRDER BOTTOM CHORD BRACE

JOIST GIRDER TO CONTINUOUS


COLUMN CONNECTION

JOIST GIRDER TO TOP OF HSS


COLUMN CONNECTION

JOIST GIRDER TO TOP OF WIDE


FLANGE COLUMN CONNECTION

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

1/8
1/4

1" MIN. (K SERIES)


2" MIN. (LH/DLH-SERIES)
This document and information herein are the
property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.

JOIST, SEE
PLAN FOR SIZE
1/8
1/4
1/8
1/4

L5x3 1/2X1/2,
L.L.V. x 6" L.

1" MIN. (K SERIES)


2" MIN. (LH/DLH
-SERIES)

VARIES

1" MIN.
(K-SERIES)
2" MIN.
(LH/DLH SERIES)

1/8
1/4

1" MIN. (K-SERIES)


2" MIN. (LH/DLH SERIES)

ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

REVISIONS

1/2" CLR.

NUMBER

DATE

REVISE BY

2"2 MIN.
3/4" EXTENDED END

1/2" RET. @
TOP

1/4

DATE

3/4" THK. STABILIZER


PLATE, TYP.

*ENGINEER'S NOTE*
CHECK AISC TABLE 10-5 FOR CAPACITY.
MIN. CAPACITY FOR CONNECTION IS 6.47K.

STEEL BEAM, SEE


PLAN FOR SIZE

NOTES:
1.
K-SERIES JOISTS SHALL HAVE MIN. 2 1/2" OF BEARING ON STEEL.
2.
LH & DLH SERIES JOISTS SHALL HAVE MIN. 4" OF BEARING ON STEEL.
3.
CONCRETE SLAB AND/OR EDGE ANGLE MAY NOT OCCUR AT ALL
LOCATIONS.

NOTES:
1.
K-SERIES JOISTS SHALL HAVE MIN. 2 1/2" OF BEARING ON STEEL.
2.
LH & DLH SERIES JOISTS SHALL HAVE MIN. 4" OF BEARING ON STEEL.
3.
CONCRETE SLAB MAY NOT OCCUR AT ALL LOCATIONS.

JOIST TO JOIST GIRDER CONNECTION

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

BEARING
BEARING
ANGLE

COORD.
SIZE
COORD.EXACT
EXACT SIZE
AND LOCATION W/
ARCH.
& &MECH.
DWGS.
ARCH.
MECH. DWGS.

STEEL
BEAM
OR JOIST,
STEEL
BEAM
OR JOIST,
SEE PLAN FOR SIZE

OR JOIST
BEAM
ROOF
ROOF BEAM
OR JOIST

L4x3x5/16
L4x3x5/16

L4x3x5/16
L4x3x5/16

4'-0"
4'-0" MAX.
MAX.

L5x3 1/2x5/16

A
A

ANGLE
FRAME
ANGLE FRAME
SHALL
BE FLUSH
SHALL
BE FLUSH
W/TOP
OF JOIST
W/TOP
OF JOIST

STEEL SHIMS AT 2'-0" O.C.


(NOT REQUIRED IF TAPERED
CURBS ARE PROVIDED,
COORD. W/ RTU SUPPLIER)

*TYP. @
EA. JOIST

3/16

MECH. UNIT CURB, SEE


MECH. DRAWINGS
MC6, EACH END OF
RTU CURB (SEE PLAN)

L4x3x5/16,
L4x3x5/16, L.L.V.,L.L.V.,
LENGTH TO SUIT
L5x3x5/16,
L5x3x5/16, L.L.V.,L.L.V.,
LENGTH
TO SUIT
LENGTH TO SUIT
L6x3 1/2x5/16
x
0'-6",
L.L.V.
x 0'-6",
L.L.V.

NEW FACILITY FOR:

7'-0"
7'-0" MAX.
MAX.

JOIST SPACING (SEE PLAN)

L5x3
1/2x5/16
L5x3 1/2x5/16

NOTE:
NOTE:
THIS
DETAIL
APPLIES
TO OPENINGS
UPWIDTH.
TO 4'-0" MAX. WIDTH.
THIS DETAIL
APPLIES
TO OPENINGS
UP TO 4'-0" MAX.

NOTE:
NOTE:
FOR
ADDITIONAL
OPENINGS
NOT
ON THE STRUCTURAL
FOR ADDITIONAL
OPENINGS
NOT SHOWN ON
THE SHOWN
STRUCTURAL
DRAWINGS, SEE ARCHITECTURAL AND MECHANICAL DRAWINGS.

SEE TYPICAL JOIST


REINFORCING DETAIL

SECTION
SECTION A-AA-A

4226.8.29.00

NOTES:
1.
K-SERIES JOISTS SHALL HAVE A MIN. 2 1/2" OF BEARING ON STEEL.
2.
LH & DLH SERIES JOISTS SHALL HAVE A MIN. 4" OF BEARING ON STEEL.
3.
CONCRETE SLAB AND/OR EDGE ANGLE MAY NOT OCCUR AT ALL LOCATIONS.

JOIST TO STEEL BEAM CONNECTION

ROOF OPENING

DHA

PROJECT NUMBER

JOIST TO EDGE BEAM CONNECTION

METAL
DECK
METAL DECK

10/01/2014

DRAWN BY

JOIST TO CONTINUOUS
COLUMN CONNECTION

SPAN
SPAN OF OF
ROOFROOF
DECK DECK

A
A

JOIST GIRDER, SEE


PLAN FOR SIZE

257 SOUTH 9TH STREET COLUMBIA, PA 17512

STEEL BEAM, SEE


PLAN FOR SIZE

KLEEN-RITE CORPORATION

NO WELD, TYP.

FRAMING DETAILS

1/2" CLR.

OR JOIST
BEAM
ROOF
ROOF BEAM
OR JOIST

1/8
1/4

JOIST AT OR NEAREST
TO THE COLUMN SHALL
BE BOLTED

*USE CAUTION WHEN WELDING AS NOT TO DAMAGE JOIST.

ROOF PENETRATION FRAMING DETAILS

ROOFTOP MECHANICAL UNIT SUPPORTS

1" = 1'-0"

1" = 1'-0"

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

S301

P
METAL DECK

MECH.
2' - 6 OPENING
1/16"
COORDINATE SIZE
AND LOCATION W/
MECH. CONTRACTOR

BEARING ANGLE

2L2x2x1/4, WELD
TO CHORD, TYP.

ANGLE FRAME
SHALL BE FLUSH
W/TOP OF JOIST

FILLET BASED
ON THK. AS
REQ'D. BY
S.J.I., TYP. T &
B BRIDGING

STEEL JOIST

L2x2x3/16 x 0'-4" W/
9/16" DIA. HOLE FOR
1/2" DIA. BOLTS
L4x3x5/16, L.L.V.,
LENGTH TO SUIT

5' - 4 13/16"
JOIST SPACING
(SEE PLAN)

STEEL JOIST,
SEE PLAN FOR
SIZE

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603

PROVIDE ADDITIONAL JOIST WEB


MEMBER WHERE "P" IS GREATER
THAN 250 LBS. OR "X" EXCEEDS 3"
P

NOTE:
FOR ADDITIONAL OPENINGS NOT SHOWN ON THE STRUCTURAL
DRAWINGS, SEE ARCHITECTURAL AND MECHANICAL DRAWINGS.

NOTES:
1.
P=APPLIED POINT LOAD.
2.
DETAIL APPLIES TO ALL CONCENTRATED LOADS APPLIED TO ROOF
JOISTS UNLESS INDICATED OTHERWISE. COORDINATE DETAIL WITH
MECHANICAL AND PLUMBING DRAWINGS.

CL. JOIST PANEL


POINT, TYP.

T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

NOTE:
CUT BRIDGING IN FIELD. ALL
CONNECTIONS FIELD WELDED (2" LAP)

ANY LOC. ON BOT. CHORD

TYPICAL MECHANICAL ROOF


PENETRATION DETAIL

TYPICAL STEEL JOIST


REINFORCEMENT DETAIL

TYPICAL HORIZONTAL WELDED


BRIDGING AT METAL STUD
WALL

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

CONCRETE SLAB
FILLET BASED
ON THK. AS
REQ'D. BY
S.J.I., TYP. T &
B BRIDGING

1 1/2" MIN.

GROUT AS
REQUIRED

FILLET BASED
ON THK. AS
REQ'D. BY
S.J.I., TYP. T &
B BRIDGING

L2x2x3/16 x 0'-4" W/
9/16" DIA. HOLE FOR
1/2" DIA. EXP. BOLTS

L2x2x3/16 x 0'-4" W/
9/16" DIA. HOLE FOR
1/2" DIA. EXP. BOLTS

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.
ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

REVISIONS
NUMBER

3/8" ANGLE OR BENT PLATE


x 6" L. @ 4'-0" O.C., EACH
SIDE OF WALL, ATTACH TO
DECK W/ (2) 1/2" DIA. BOLTS

DATE

REVISE BY

BOND BEAM W/
(2) #5, CONT.

DATE
DRAWN BY

NOTE:
WHERE DECK SPANS PERPENDICULAR TO WALL THE
LENGTH OF THE ANGLE OR BENT PLATE SHALL BE AS
REQUIRED SO THAT CONNECTION IS MADE TO (2)
ADJACENT DECK FLUTES.

DHA
4226.8.29.00

PROJECT NUMBER

TYPICAL HORIZONTAL WELDED


BRIDGING AT MASONRY WALL

TYPICAL HORIZONTAL WELDED


BRIDGING AT CONCRETE WALL

TOP OF NON-LOAD BEARING INTERIOR CMU WALL

1" = 1'-0"

1" = 1'-0"

1" = 1'-0"

MASONRY ANCHORS
@ 16" O.C.,TYP.

STEEL COLUMN

NEW FACILITY FOR:

SOLID GROUT

257 SOUTH 9TH STREET COLUMBIA, PA 17512

NOTE:
CUT BRIDGING IN FIELD. ALL
CONNECTIONS FIELD WELDED (2" LAP)

10/01/2014

KLEEN-RITE CORPORATION

NOTE:
CUT BRIDGING IN FIELD. ALL
CONNECTIONS FIELD WELDED (2" LAP)

FRAMING DETAILS

L6x3 1/2x5/16 x 0'-6", L.L.V.

1" CLR. MIN.

L5x3x5/16, L.L.V.,
LENGTH TO SUIT

ARCHITECTS

CMU ANCHORAGE TO STEEL COLUMNS


1" = 1'-0"

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

S302

.5

COLUMN BEYOND, TYP.


25' - 0"
1/2" DIA. A325N BOLT @
EA. END OF "Z" GIRT OR
CHANNEL, SHIM AS REQ'D.

SPACING MAX.

9ZS2.25X105 GIRTS
3'-6" O.C.

25' - 0"

"Z" GIRT OR CHANNEL W/ (2)


1/2" DIA. A325N BOLT, (SEE
ELEVATIONS FOR SIZE AND
SPACING)

METAL WALL PANEL

ARCHITECTS

L8x4x1/2 x 16" L, TYP.

L8x4x1/2 x 16" LONG


C9x15

16' - 0"

TYP. BOTH
SIDE

CMU WALL, REFER


TO ARCH. PLANS
FOUNDATION PLAN
333' - 0"
NOTE:
DOORS IN CMU WALLS NOT SHOWN FOR CLARITY. SEE ARCHITECTURAL DRAWING FOR EXACT DOOR AND WINDOW LOCATIONS.

TYP. EA.
SIDE

B
C9x20 W/ 1/2" DIA. HILTI
KWIK BOLT 3 EXP. ANCHOR
@ 16" O.C. TO TOP OF BOND
BEAM (3" MIN. EMBED)

3/16

8" BOND BEAM W/


(2) #5 CONT.

TYP.
3/16

2" MAX.

NOTCH CMU AT ANGLE


TO ENSURE CHANNEL IS
FLUSH W/ TOP OF WALL

SEE FND PLAN FOR


COLUMN SIZE, TYP.

PROVIDE (8) 1/4" DIA.


SELF-TAPPING
SCREWS, TYP.

1 1/2"

C9x15

T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

3/4" MAX.

3' - 6"

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603

1' - 6" OVERLAP

SECTION B-B

NOTE:
PRE-DRILL HOLES

TYPICAL WALL FRAMING

TYPICAL TOP OF CMU WALL & WIND COL. DETAIL

"Z" GIRT LAP DETAIL

1/8" = 1'-0"

1" = 1'-0"

1" = 1'-0"

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.
ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

3/16

REVISIONS
NUMBER

DATE

REVISE BY

TYP.
3/16

L3x3x1/4

PROVIDE
DOUBLE NUT

L3x3x5/16 KICKER TO ADJ.


JOIST TOP CHORD; WELD
ENDS, TYP.
DATE

3"

1/4

10/01/2014

DRAWN BY

2" MIN.

DHA
4226.8.29.00

PROJECT NUMBER

5/16" THK. PL
3/8" THK. x 4" WIDE PL
Z-GIRT OR CHANNEL
DEPENDING ON
LOCATION
NOTE:
CENTER ANGLE & SAG ROD ON PL.

TYPICAL SAG ROD DETAIL

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

WALL DETAILS

257 SOUTH 9TH STREET COLUMBIA, PA 17512

KLEEN-RITE CORPORATION

NEW FACILITY FOR:

1" = 1'-0"

S304

6.5

2.5

2.3

ROOF FRAMING PLAN


364' - 2 1/2"

ROOF FRAMING PLAN


364' - 2 1/2"

HS
S4
-1
/2
X4
-1
/2
X1
/4

MEZZANINE FRAMING
PLAN
350' - 0"

ARCHITECTS

1
/2X
4-1
2X
-1/
S4
HS

HS
S4
-1
/2
X4
-1
/2
X1
/4

HS
S4
-1/
2X
4-1
/2X
1/4

/4
X1
/2
-1
X4
/2
-1
S4
HS

/4
X1
/2
-1
X4
/2
-1
S4
HS

MEZZANINE FRAMING
PLAN
350' - 0"

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603
T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

/4

FOUNDATION PLAN
333' - 0"

FOUNDATION PLAN
333' - 0"

BRACING ELEV @ COL. LINE A

BRACING ELEV @ COL. LINE D

1/8" = 1'-0"

1/8" = 1'-0"

B.5

7.5

ROOF FRAMING PLAN


364' - 2 1/2"

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.

HS
S4
-1
/2
X4
-1
/2
X1
/4

/4
X1
/2
-1
X4
/2
-1
S4
HS

HS
S4
-1
/2
X4
-1
/2
X1
/4

ROOF FRAMING PLAN


364' - 2 1/2"

MEZZANINE FRAMING
PLAN
350' - 0"

ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

REVISIONS

MEZZANINE FRAMING
PLAN
350' - 0"

NUMBER

DATE

REVISE BY

HS
S4
-1
/2
X4
-1
/2
X1
/4

4
1/
2X
1/

/4
X1
/2
-1
X4
/2
-1
S4
HS

X4
/2
-1
S4
HS

DATE

FOUNDATION PLAN
333' - 0"

FOUNDATION PLAN
333' - 0"

10/01/2014

DRAWN BY

DHA
4226.8.29.00

BRACING ELEV @ COL. LINE B

1/8" = 1'-0"

1/8" = 1'-0"

C.5

B.5

A.7

A.5

A.1

4
1/
2X

HS
S4
-1
/2
X4
-1
/2
X1
/4

/
-1
X4
/2
-1
S4
HS

/4
X1
/2
-1
X4
/2
-1
S4
HS

HS
S4
-1
/2
X4
-1
/2
X1
/4

ROOF FRAMING PLAN


364' - 2 1/2"

X4
-1
/2
X1
/4

NEW FACILITY FOR:

4
1/
2X

HS
S4
-1
/2

/
-1
X4
/2
-1
S4
HS

/4
X1
/2
-1
X4
/2
-1
S4
HS

HS
S4
-1
/2
X4
-1
/2
X1
/4

MEZZANINE FRAMING
PLAN
350' - 0"

257 SOUTH 9TH STREET COLUMBIA, PA 17512

BRACING ELEV @ COL. LINE 1

KLEEN-RITE CORPORATION

PROJECT NUMBER

LATERAL BRACING ELEVATIONS

FOUNDATION PLAN
333' - 0"

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

BRACING ELEV @ COL. LINE 5


1/8" = 1'-0"

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

S401

C
1

CONNECTION DESIGN BY OTHERS

EQ

SEE BRACED FRAME


ELEVATIONS FOR
MEMBER SIZES,
DIMENSIONS,
ORIENTATIONS (TYP.)

ARCHITECTS

EQ

G,
DE
30

941 WHEATLAND AVENUE, SUITE402


LANCASTER, PA 17603

N
MI

18"x18"x1 1/4" THK. BASE PLATE

CL.

T 717.735.8166 // F 717.735.8169
TONOARCHITECTS.COM

ERECTION BOLT

18"x18"x1 1/4" THK. BASE PLATE


5/16

1" THK. GROUT

4 SIDES

SEE NOTE 4

GROUT POCKET

1/2" ISOLATION JOINT MATERIAL


FOUNDATION PLAN
333' - 0"

FOUNDATION PLAN
333' - 0"

14"x3"x1 1/4" SHEAR


LUG (@ BRACE
LOCATIONS ONLY)

SEE PIER & COL. FTG.


SCHEDULE FOR SIZE & REINF.

SEE PIER & COL. FTG.


SCHEDULE FOR SIZE & REINF.

1" DIA. ASTM F1554 GRADE


36 ANCHOR BOLTS W/ 24"
EMBEDMENT

2' - 0"

14"x3"x1 1/4" SHEAR


LUG (@ BRACE
LOCATIONS ONLY)

COLUMN BASE PLATE

NOTES:
1.
DESIGN OF BRACING CONNECTIONS SHALL BE IN
ACCORDANCE WITH THE AISC UNIFORM FORCE METHOD.
2.
SEE BRACE ELEVATION FOR DESIGN FORCES.
3.
SLOTS IN HSS BRACE MEMBERS SHALL BE A MAXIMUM OF
1/8" WIDER THAN GUSSET PLATE THICKNESS (1/16" MAX, EA.
SIDE) AND THE SLOT MAY EXTEND UP TO 1" PAST THE EDGE
OF THE GUSSET PLATE, TYP.
4.
THE SMALLER OF EITHER a.) THE VERTICAL DISTANCE FROM
THE HSS BRACE TO THE BEAM FLANGE, OR b.) THE
HORIZONTAL DISTANCE FROM THE HSS BRACE TO THE EDGE
OF THE GUSSET PLATE CONNECTION ANGLES SHALL NOT
EXCEED 3".

1" DIA. ASTM F1554 GRADE


36 ANCHOR BOLTS W/ 24"
EMBEDMENT

This document and information herein are the


property of TONO Architects, LLC and may
not be reproduced or copied in any form
without written authorization from TONO
Architects, LLC. Unauthorized reproduction
or
use of any or all parts of this drawing will
constitute a violation of U.S. copyright laws.
ALL RIGHTS RESERVED . TONO ARCHITECTS, LLC . COPYRIGHT 2013

REVISIONS
5
S402

SECTION

1" = 1'-0"

COLUMN CAP PLATE

SECTION

TYPICAL HSS BRACING CONNECTION TO BASE OF COLUMN WEB

1" = 1'-0"

1" = 1'-0"

S402

NUMBER

1/2" CLR, TYP.

DATE

REVISE BY

DATE

10/01/2014

DRAWN BY

DHA
4226.8.29.00

PROJECT NUMBER

SEE BRACED FRAME


ELEVATIONS FOR MEMBER
SIZES, DIMENSIONS, AND
ORIENTATIONS

SEE NOTE 5

CL.
1/4
3" CLR. MAX, TYP.

EQ.

STIFFENER PLATE EACH


SIDE OF WEB AS REQ'D.

DOUBLE ANGLE W/
A325SC BOLTS
ERECTION BOLT

CL.

SEE NOTE 5

CL.

EQ

ERECTION BOLT, TYP.


1"

CL.

EQ

EQ

EQ
EQ

1"

4 SIDES, TYP.
EQ

P.
TY
"
1

1"

CL.

NOTES:
1.
DESIGN OF BRACING CONNECTIONS SHALL BE IN
ACCORDANCE WITH THE AISC UNIFORM FORCE METHOD.
2.
SEE BRACE ELEVATION FOR DESIGN FORCES.
3.
IF GUSSET LENGTH EXCEEDS MIN. GUSSET TO BEAM WELD
LENGTH, PROVIDE A MIN. 3-12 WELD PATTERN FOR THE
REMAINING LENGTHOF PLATE ON EACH SIDE OF THE
CONTINUOUS WELD.
4.
SLOTS IN HSS BRACE MEMBERS SHALL BE A MAXIMUM OF
1/8" WIDER THAN GUSSET PLATE THICKNESS (1/16" MAX. EA.
SIDE), AND THE SLOT MAY EXTEND UP TO 1" PAST THE EDGE
OF THE GUSSET PLATE, TYP.

NOTES:
1.
DESIGN OF BRACING CONNECTIONS SHALL BE IN ACCORDANCE WITH THE AISC UNIFORM FORCE METHOD.
2.
SEE BRACE ELEVATION FOR DESIGN FORCES.
3.
ALL BOLTS SHALL BE A325 SLIP CRITICAL (SC) BOLTS IN STANDARD SIZE HOLES.
4.
SLOTS IN HSS BRACE MEMBERS SHALL BE A MAXIMUM OF 1/8" WIDER THAN GUSSET PLATE THICKNESS
(1/16" MAX, EA. SIDE) AND THE SLOT MAY EXTEND UP TO 1" PAST THE EDGE OF THE GUSSET PLATE, TYP.
5.
THE SMALLER OF EITHER a.) THE VERTICAL DISTANCE FROM THE HSS BRACE TO THE BEAM FLANGE, OR
b.) THE HORIZONTAL DISTANCE FROM THE HSS BRACE TO THE EDGE OF THE GUSSET PLATE CONNECTION
ANGLES SHALL NOT EXCEED 3".

TYPICAL HSS BRACING CONNECTION AT BEAM TO COLUMN WEB

TYPICAL HSS BRACING CONNECTION AT BEAM

1" = 1'-0"

1" = 1'-0"

BRACING CROSSOVER DETAIL


1" = 1'-0"

NEW FACILITY FOR:

30 DEG
MIN, TYP.

1"

SEE BRACED FRAME


ELEVATIONS FOR MEMBER
SIZES, DIMENSIONS,
ORIENTATIONS (TYP.)

Excellence in Civil Engineering


38 NORTH DUKE STREET, YORK, PA

PHONE (717) 846-4805

FAX (717) 846-5811

315 WEST JAMES STREET, LANCASTER, PA

PHONE (717) 481-2991

FAX (717) 481-8690

50 WEST MIDDLE STREET, GETTYSBURG, PA

PHONE (717) 337-3021

FAX (717) 337-0782

WWW.CSDAVIDSON.COM

PROGRESS SET - NOT FOR CONSTRUCTION

LATERAL BRACING DETAILS

1/2" THK. PLATE

257 SOUTH 9TH STREET COLUMBIA, PA 17512

.,
IN
M P.
1" TY

4 SIDES

KLEEN-RITE CORPORATION

BRACE MEMBER
DOUBLE ANGLE
W/ A325SC BOLTS

S402

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\3-D RENDERINGS.DWG 10-08-14 1:22 PM PRINTED BY: JOESLAGLE

30% PROGRESS DRAWING


ALL MASONRY

257 SOUTH 9TH STREET COLUMBIA PA 17512

KLEEN- RITE CORPORATION

NEW WAREHOUSE FOR:

I:\2014\14-665 KLEEN-RITE WAREHOUSE 30% DOC\DESIGN\CAD\3-D RENDERINGS.DWG 10-08-14 1:22 PM PRINTED BY: JOESLAGLE

30% PROGRESS DRAWING


MASONRY AND METAL SIDING

257 SOUTH 9TH STREET COLUMBIA PA 17512

KLEEN- RITE CORPORATION

NEW WAREHOUSE FOR: