ETABS 2015 Concrete Frame Design

IS 456:2000 Column Section Design

Column Element Details Type: Ductile Frame (Flexural Details)


Level

Element

Unique Name

Section ID

Combo ID

Station Loc

Length (mm)

LLRF

G.F FLOOR SLAB

C4

137

C900X750-M30

COMB2

4000

Section Properties
b (mm)

h (mm)

dc (mm)

Cover (Torsion) (mm)

750

900

52.5

22

Material Properties
Ec (MPa)

fck (MPa)

Lt.Wt Factor (Unitless)

fy (MPa)

fys (MPa)

27386.13

30

500

500

Design Code Parameters


C

1.5

1.15

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3


Design Pu
kN

Design Mu2
kN-m

Design Mu3
kN-m

Minimum M2
kN-m

Minimum M3
kN-m

Rebar Area
mm

Rebar %
%

15416.7056

-486.3971

-35.2777

486.3971

563.4806

24401

3.62

Factored & Minimum Biaxial Moments


NonSway Mns
kN-m

Sway Ms
kN-m

Factored Mu
kN-m

Major Bending(Mu3 )

-35.2777

-35.2777

Minor Bending(Mu2 )

-15.6303

-15.6303

Slenderness Effects (IS 39.7.1) and Minimum Biaxial Moments (IS 39.2, 25.4)
End Moment
Mu1 (kN-m)

End Moment
Mu2 (kN-m)

Initial
k*Ma
Minimum
Minimum
Moment (kN-m) Moment (kN-m) Moment (kN-m) Eccentricity (mm)

Major Bending (M3 )

-35.2777

93.5414

42.0138

563.4806

36.6

Minor Bending (M2 )

-15.6303

173.8162

98.0376

486.3971

31.6

Effective Length Factors (IS 25.2, Annex E)


K
Sway

K
Non-Sway

Framing
Type

P-Delta
Done?

Major Bend(M3 )

6.340425

0.978762

Ductile Frame

Minor Bend(M2 )

4.191142

0.95237

Ductile Frame

Page 1 of 2

Q
Factor

K
Used

Yes

0.07583

Yes

0.043085

Additional Moment Reduction Factor k (IS 39.7.1.1)


Ag
cm

Asc
cm

Puz
kN

Pb
kN

Pu
kN

k
Unitless

6750

244

18263.0377

5711.2828

15416.7056

0.226768

Additional Moment (IS 39.7.1)


Consider
Ma

Length
Factor

Section
Depth (mm)

KL/Depth
Ratio

KL/Depth
Limit

KL/Depth
Exceeded

Ma
Moment (kN-m)

Major Bending (M3 )

Yes

0.819

900

3.639

12

No

Minor Bending (M2 )

Yes

0.819

750

4.367

12

No

Page 2 of 2