PART - I Answer any Two questions Assume reasonable values of any data, if required (S456-2000, IS3370 and SP16 are allowed in the examination hall. 1.
Design a RCC slab panel dimension 5m x 6m against a live
load = 2KN/m2. Two adjacent edges of the slab panel are continuous and remaining two edges are discontinuous. Apply _ "limit state method of design" according to IS 456 2000. Consider M20 grade of concrete and Fe 415 grade HYSD bars. Check against deflection also.
2.
25
Design a RCC short column with a suitable pile cap against an
axial
compressive
Mx = 200 KN
force
P = 1500KN
and
moments
and My = 150 KN . Partial safety factor
against load = 1.2.
Apply Limit state method of design
according to IS4562000. Capacity of 450 dia piles = 425 KN.
Consider M20 grade of concrete and Fe 415 grade HYSD bars.
25
[ Turn over
- 3 -
-23.
Design the short wall and longwall of a RCC underground
Determine the maximum bending moment at centre and at
quarter span due to class AA tracked loading. Also determine the maximum shear free at support and at quarter span. 25
water tank of dimension 6m x 2.8m x 2.5 high. Water table
may be considered at GL. soil =16 KN/m3. bt = 1.8 N/mn2. Consider M20 grade of concrete and Fe415 grade of HYSD bars.
25 Part - II
Assume reasonable values of data if required. IS-875 (all parts),
IS-1893, IRC-6 and IRC-21 are allowed in the examination hall. Answer any two questions. 4.
5.
A commercial building (25m x 25m in plan) has 10 storeys and
located at Chennai. Columns are placed 5m c/c along both direction. The floor to floor height of the building is 3.0m. Calculate the lateral forces due to wind. Determine the bending moment and shear force of the beams and columns at 6th floor level. Show also the B.M and S.F diagrams. 25 A R.C.C. tee beam (simply supported) bridge is to be constructed for a river crossing a National Highway. The following data is given l
Clear width of roadway = 7.5 m
Average thickness of wearing coat = 100mm.
No. of Main girder = 3
No. of Cross girder = 6
Spacing of Main girder = 2.4m
Span of the bridge (c/c of bearing) = 24m
Size of Kerb = 300mm (depth) x 700mm (width)
Height of parnpet railing = 1m.
6.
a)
State the various vertical irregularities in buildings in
connection with seismic analysis. 3
b)
What is the significance of Response Reduction factor? 2
c)
List the loading combinations to be considered for DL, LL,
WL, EL. 3
d)
What are the different types of losses in prestressing?
e)
Draw the brusting stress diagram in the anchorage zone and
explan it? 3
f)
A post tension beam (300mm x 500mm) is simply supports
over a span of 12m. 2 cables each 5 No.10 are located at an eccentricity of 100mm. Initial prestress = 1600 MPa. Calculate (a) Deflection at the centre of span due prestress and self weight (b) Deflection at the centre at service condition. Assume 20% loss of prestress, grade of concrete = M 35 and superimposed live load = 18KN/m. 12