Performance monitoring

The 40G MUX OCI circuit pack supports the following monitored entities:
OTM3 mapping layer interface
PM collection for ODU3 layer
Protection switch count/duration for ODU3 layer
OTM2 mapping layer interface
PM collection for ODU2 layer
Client interfaces
PM collection of SONET section (S)/SDH regenerator section (RS)
and SONET line (L)/SDH multiplex section (MS) for OC-192/STM-64
facility
PM collection for OTU2 layer
PM collection for ODU2 layer
PM collection for TCMTTP, TCMCTP, ETH10G, FLEX (FC800 and
FC1200), and WAN facilities
PM collection for Physical layer, except for WAN facilities
operational measurements for ETH10G, FLEX (FC800 and FC1200),
and WAN facilities
The 40G MUX OCI circuit pack supports the following monitored entities when
mated with a 40G OTN XCIF circuit pack:
PM collection for STTP facilities
PM collection for OTUTTP facilities
PM collection for ETTP facilities
PM collection for PTP facilities
operational measurements for ETTP facilities
For detailed information and procedures associated with performance
monitoring, refer to Fault Management - Performance Monitoring,
323-1851-520.

Alarms
For a complete list of alarm clearing procedures for 6500, refer to Part 1 and
Part 2 of Fault Management - Alarm Clearing, 323-1851-543.
Equipment alarms

Circuit Pack Missing


Circuit Pack Mismatch
Circuit Pack Failed

1-54 40G, OSIC, SLIC10, and SLIC10 Flex circuit packs


6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014

Autoprovisioning Mismatch
Intercard Suspected
Internal Mgmt Comms Suspected

Circuit Pack Latch Open


Provisioning Incompatible
Database Not Recovered For Slot
Circuit Pack Upgrade Failed
Cold Restart Required: FPGA Changed
Pluggable alarms

Circuit Pack Missing - Pluggable


Circuit Pack Mismatch - Pluggable
Circuit Pack Failed - Pluggable
Circuit Pack Unknown - Pluggable
Autoprovisioning Mismatch - Pluggable
Intercard Suspected - Pluggable
Provisioning Incompatible - Pluggable
OTM facility alarms

Loss Of Signal
Loss Of Clock
Loss Of Frame
Loss Of Multiframe
Pre-FEC Signal Fail
Pre-FEC Signal Degrade
Rx Power Out Of Range
OTU Trace Identifier Mismatch
OTU Signal Degrade
OTU BDI
ODU AIS
ODU LCK
ODU OCI
ODU Trace Identifier Mismatch
ODU BDI
OPU AIS

40G, OSIC, SLIC10, and SLIC10 Flex circuit packs 1-55


6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014

OPU Payload Type Mismatch


GCC0 Link Failure
GCC1 Link Failure
GCC0 OSPF Adjacency Loss
GCC1 OSPF Adjacency Loss
Laser Off far End Failure Triggered
Loopback Active - Facility
Loopback Active - Terminal

Protection Scheme Mismatch


Protection Mode Mismatch
Protection Switch Byte Fail
Auto Protection Switch Acknowledge Time Out
Protection Exerciser Failed
Protection Switch Complete - Revertive
Forced Switch Active
Manual Switch Active
Lockout Active
Far End Protection Line Fail
Multiplexed Rate Mismatch
TX Tuning in Progress
TX Manual Provisioning Required
OCn/STMn facility alarms

Loss Of Signal
Loss of Clock
Loss Of Frame
AIS
Trace Identifier Mismatch
Signal Fail
RFI
Laser Off far End Failure Triggered
Loopback Active - Facility
Loopback Active - Terminal
Rx Power Out of Range

1-56 40G, OSIC, SLIC10, and SLIC10 Flex circuit packs


6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014

Frequency Out of Range


TX Manual Provisioning Required
TX Tuning in Progress

Ethernet and fiber channel facility alarms

Loss Of Signal
Loss of Clock
Loss Of Frame
Excessive Error Ratio
Local Fault
Remote Fault
Laser Off far End Failure Triggered
Loopback Active - Facility
Loopback Active - Terminal

Rx Power Out of Range


Frequency Out of Range
TX Manual Provisioning Required
TX Tuning in Progress
OTUTTP facility alarms

Loopback Active - Facility


Loopback Active - Terminal
Loss of Frame
Loss Of Multiframe
Loss of Clock
Pre-FEC Signal Fail
Pre-FEC Signal Degrade
OTU Signal Degrade
OTU BDI
OTU Trace Identifier Mismatch
ETTP facility alarms

Loss of Clock
Loss Of Frame
Excessive Error Ratio
Local Fault

40G, OSIC, SLIC10, and SLIC10 Flex circuit packs 1-57


6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014

Remote Fault
Loopback Active - Facility
Loopback Active - Terminal
Frequency Out of Range
OPU Payload Type Mismatch
OPU AIS
Far End Client Signal Fail
STTP facility alarms

Loss of Clock
Loss Of Frame
AIS
RFI
Signal Fail
Signal Degrade
Frequency Out of Range
OPU Payload Type Mismatch
OPU AIS
Far End Client Signal Fail

Loopback Active - Facility


Loopback Active - Terminal
Flex facility alarms

Loopback Active - Facility


Loopback Active - Terminal
Loss of Signal
Loss of Data Synch
Loss of Clock
Excessive Error Ratio
Laser Off far End Failure Triggered
Rx Power Out of Range
Fiber Channel Link Not Operational
Local Fault
Remote Fault

1-58 40G, OSIC, SLIC10, and SLIC10 Flex circuit packs


6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014
TCM Facility alarms

ODU BDI
ODU AIS
ODU LCK
ODU OCI
TCM Loss of Tandem Connection
ODU Signal Degrade
WAN alarms

Link Down
Loss of Frame delineation
Far End Client Rx Signal Failure
CMF UPI Mismatch
Photonic alarms

Adjacency Mismatch
Duplicate Adjacency Discovered

Software Auto-Upgrade alarms

Software Auto-Upgrade in Progress


Software Auto-Upgrade Failed

40G, OSIC, SLIC10, and SLIC10 Flex circuit packs 1-59


6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014

Equipping rules

The following equipping rules apply to 40G MUX OCI circuit packs:
is a four-port single slot interface

can be equipped in any slot (1-14 except slots 7 and 8 if cross-connect


circuit packs are provisioned in slots 7 and 8) of the 14-slot packet-optical,
converged optical, converged optical/front electrical, or converged
optical/rear electrical shelves. Slots 7 and 8 of a 14-slot packet-optical
shelf (NTK503SA) cannot be equipped with this circuit pack.
Attention: All 40G-capable slots in a 6500 shelf can be equipped with 40G
groups if the shelf is adequately powered. However, for specific feeder
ratings and combinations of circuit packs, full-fill may not be possible and
some or all of the remaining slots may need to be equipped with filler circuit
packs to avoid exceeding shelf power capacity. Prior to equipping the shelf
with high power circuit packs, you must always consider power budgeting
and power feeds by referring to the "Power specifications" section in Part 3
of 6500 Planning, NTRN10CF (Chapter 8).
can be equipped in slots 1-8, 11-18, 21-28, and 31-38 of the 32-slot
packet-optical shelf
can be equipped in slots 1 to 7 of the 7-slot optical shelf.
both NTK525CAE5 and NTK525CFE5 variants of 40G MUX OCI circuit
pack cannot be equipped in the NTK503MAE5 and NTK503NAE5 variants
of 2-slot shelf.
NTK525CFE5 variant of 40G MUX OCI circuit pack can be equipped in
slots 1 and 2 of the NTK503LA variant of 2-slot shelf.
can be equipped in the same shelf with any other type of circuit pack.
any adjacent two-slot combination of 40G MUX OCI/40G OCLD or 40G
MUX OCI/Wavelength-selective 40G OCLD is possible (for example, 40G
MUX OCI circuit pack on left or right of 40G OCLD or
Wavelength-selective 40G OCLD circuit pack) starting in any slot with the
exception of connections across slots 6 to 7 and 8 to 9 for 14-slot shelf
types. Note that if you are planning full-fill unprotected or regen 40G
applications, connections across the above slots will not occur, as they will
be using the recommended slots 1 to 2, 3 to 4, 5 to 6, 7 to 8 (not applicable
to 14-slot packet-optical shelf (NTK503SA)), 9 to 10, 11 to 12, and 13 to
14 for 14-slot shelf types. However for 40G MUX OCI/40G UOCLD slot
combination, you must see the details in 40G UOCLD circuit packs
(NTK539XAE5 and NTK539XEE5) on page 1-75.
1-60 40G, OSIC, SLIC10, and SLIC10 Flex circuit packs
6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014

In a 2-slot optical Type 2 shelf assembly (NTK503LA) and when one 40G
OCLD circuit pack is mated with one 40G MUX OCI circuit pack
(NTK525CFE5 variant) (MOTR configuration), the 40G OCLD can be in

slot 1 or 2 and 40G MUX OCI circuit pack can be in other slot.
a 40G MUX OCI circuit pack between two 40G OCLD or
Wavelength-selective 40G OCLD circuit packs provides 1+1 OTN line-side
protection. Signals are exchanged between triplets using the backplane.
For 1+1 protection, the choices are:
slots {1,2,3}, {4,5,6}, {9,10,11}, and {12,13,14} for 14-slot shelf types
slots {1,2,3}, {4,5,6}, {13,14,15}, {16,17,18}, {21,22,23}, {24,25,26},
{33,34,35}, and {36,37,38} for 32-slot shelf type.
slots {1,2,3} and {4,5,6} for 7-slot shelf type.
a 40G MUX OCI circuit pack between two 40G UOCLD circuit packs
provides 1+1 OTN line-side protection. Signals are exchanged between
triplets using the backplane. For 1+1 protection, the choices are
slots {2,3,4,5,6} and {10,11,12,13,14} for 14-slot shelf types
slots {2,3,4,5,6}, {14,15,16,17,18}, {22,23,24,25,26}, and
{34,35,36,37,38} for 32-slot shelf type.
slots {2,3,4,5,6} for 7-slot shelf type.
two 40G MOTR groups (40G MUX OCI/40G OCLD or 40G MUX OCI/
Wavelength-selective 40G OCLD while 40G MUX OCI circuit pack must
be NTK525CFE5 variant) provisioned in consecutive slots can be
configured as 1+1 protection using TPT (without any cross-connect). The
first 40G MOTR group must be in the lower numbered slots (considered
the working path) and the second 40G MOTR group must be in the higher
numbered slots (considered the protection path). The working/protection
path slot is the slot number in which the working/protection 40G MUX OCI
is seated. The 40G MUX OCI circuit packs must always be in the odd slots
and the 40G OCLD or Wavelength-selective 40G OCLD circuit packs in
the adjacent even slots. The working and protection 40G MUX OCI circuit
packs require an XFP on the client interface. The 40G OCLD or
Wavelength-selective 40G OCLD at one end of protection group must talk
to the same 40G OCLD or Wavelength-selective 40G OCLD at the other
end of protection group.
any adjacent two-slot combination of 40G MUX OCI/40G OTN XCIF is
possible as long as 40G OTN XCIF circuit pack is in even slot (for example,
40G MUX OCI circuit pack on left side of 40G OTN XCIF circuit pack). The
exception is slot 8 for 14-slot shelf type, and slot 10 for 32-slot shelf type.
The use of NTK525CAE5 variant of 40G MUX OCI circuit pack is not
supported in combination with 40G OTN XCIF.
the maximum number of back-to-back 40G Mux OCI regenerator sites is
eight.
40G, OSIC, SLIC10, and SLIC10 Flex circuit packs 1-61
6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs

Release 9.3 323-1851-102.4 Standard Issue 3


Copyright 2010-2014 Ciena Corporation February 2014

Attention: The regen limits do not apply to "daisy chain/ loopback" systems
acceptance test set soaks. It is expected that the number of
"daisy chain/ loopback" XFP connections can exceed these limits for idle test
set soaks (no fiber pulls, card re-seats, protection switching, etc.) at ambient
temperature with nominal clock frequencies.
requires high flow cooling fan modules (NTK507LDE5, NTK507MDE5,
NTK507LS, and NTK507MS) when equipped in a 14-slot shelf.
does not use any cross-connect capacity and can be installed in shelves
equipped with or without cross-connect circuit packs
The following restrictions on using a cross-connect circuit pack are applied
when deploying a 40G MUX OCI circuit pack:
In a 14-slot shelf type (except for 14-slot packet-optical shelf type;
NTK503SA), you cannot provision a 40G MUX OCI circuit pack in slot 7 or
8 if one of these slots already contains a cross-connect circuit pack. Slots
7 and 8 of a 14-slot packet-optical shelf (NTK503SA) cannot be equipped
with 40G MUX OCI circuit packs.
In a 14-slot shelf type (except for 14-slot packet-optical shelf type;
NTK503SA), you cannot provision a cross-connect circuit pack in slot 7 or
8 if one of these slots already contains a 40G MUX OCI circuit pack. Slots
7 and 8 of a 14-slot packet-optical shelf (NTK503SA) cannot be equipped
with 40G MUX OCI circuit packs.
In a 14-slot shelf type (except for 14-slot packet-optical shelf type;
NTK503SA), when the 40G MUX OCI circuit packs are installed in slot 7
or 8, only Broadband circuit packs or Photonic circuit packs can be
provisioned in the other interface slots (slots 1 to 6 and 9 to14), as MSPP
interface circuit packs require a cross-connect circuit pack. Slots 7 and 8
of a 14-slot packet-optical shelf (NTK503SA) cannot be equipped with
40G MUX OCI circuit packs. See Part 1 of 6500 Planning, NTRN10CF
(Chapter 3) for a full list of supported Broadband and Photonic circuit
packs.
1-62 40G, OSIC, SLIC10, and SLIC10 Flex circuit packs
6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014

Technical specifications

Table 1-11 lists the weight, power consumption, and XFP specifications for the
40G MUX OCI optical interface circuit pack.

Latency

Refer to Latency specifications for 40G circuit packs on page 1-126 for 40G

MUX OCI latency values.

Table 1-11
Technical specifications for 40G MUX optical interface circuit pack
Parameter 40G MUX OCI
NTK525CAE5 NTK525CFE5
Weight (estimated) 1.1 kg (2.5 lb) 1.0 kg (2.2 lb)
Power consumption Typical (W): 80 (see
Note 1 and Note 3)
Power Budget (W): 88
(see Note 2 and Note 3)
Typical (W): 36 (see
Note 1 and Note 3)
Power Budget (W): 36
(see Note 2 and Note 3)
XFP specifications (see Note 4)
Note 1: The typical power consumption values are based on operation at an ambient temperature
of
25 (+/-3oC) and voltage of 54 V dc (+/-2.5 V).
Note 2: The power budget values are based on the maximum power consumption in an ambient
temperature range from 5oC to 40oC at a voltage of 40 V dc (+/-2.5 V). These values must be used
in
sizing feeders and estimating theoretical maximum power draw.
Note 3: For this circuit pack that must be equipped with XFPs, the power values published in this
table
do not include XFPs power values. You must add 2 W to typical power value and 3 W to power
budget
for each XFP module with reach less than IR-2/S-64.2b. You must add 3 W to typical power value
and
4 W to power budget for each XFP module with IR-2/S-64.2b reach or greater.
Note 4: For optical XFP client specifications, see the following sections in Part 3 of 6500
Planning,
NTRN10CF (Chapter 8):
Optical specifications for 10G XFPs used for SONET/SDH applications
Optical specifications for 10G XFPs used for 10G Ethernet applications
XFP transmitter, receiver, and link specifications for OTU2 applications
Multirate DWDM/CWDM XFP optical specifications
Multirate Tunable DWDM XFP optical specifications
40G, OSIC, SLIC10, and SLIC10 Flex circuit packs 1-63
6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014

40G XCIF circuit pack (NTK525FAE5)


Overview

The XC I/F 40G STS-1/HO circuit pack (also referred to as 40G XCIF) allows
STS-n grooming capabilities between 6500 MSPP interfaces and 6500

40G OCLD, Wavelength-selective 40G OCLD, or 40G UOCLD circuit packs by


using the shelf cross-connect circuit pack. It provides the following
capabilities:
40G line integration within 6500 MSPP applications
40G interfacing with the existing cross-connect architecture
leveraging of the existing STS traffic routing and protection capabilities of
the cross-connect for 40G circuit packs
The 40G XCIF circuit pack provides up to 40G of bandwidth shared between
two slots for STSn/STMn traffic as follows:
20G from/to the cross-connect circuit pack to/from the 40G XCIF slot
20G from/to the cross-connect circuit pack via the mate 40G OCLD,
Wavelength-selective 40G OCLD, or 40G UOCLD slot to/from the
40G XCIF slot
Attention: The NTK525CFE5 variant of the 40G MUX OCI circuit pack does
not interwork with the 40G XCIF circuit pack (NTK525FAE5) in a 40G link.
Use the NTK525CAE5 variant of 40G MUX OCI circuit pack to interwork with
the 40G XCIF circuit pack in a 40G link.
Figure 1-13 on page 1-64 shows the faceplate of a 40G XCIF circuit pack and
Figure 1-14 on page 1-65 shows the functional block diagram of a 40G XCIF
circuit pack.
1-64 40G, OSIC, SLIC10, and SLIC10 Flex circuit packs
6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3
Copyright 2010-2014 Ciena Corporation February 2014
Figure 1-13
40G XCIF circuit pack faceplate
Type A

XC I/F
40G STS-1/HO
Fail
Ready
In Use

S/N NT030MEE9999E
NTUD99EE
EEEEE99999
R99

Green rectangle (Ready)


- Used to communicate hardware or software functional state
- Card initializing = Blinking LED; Card OK = LED on; Card not ready = LED off
Red triangle (Fail)
- Used to communicate hardware or software failure state
- Card not failed = LED off, Card failed = LED on
Blue diamond (In Use)
- Used to communicate whether circuit pack can be extracted
(on->no pull, off->can be pulled)
- Equipment in-service = LED on; Equipment out-of-service = LED off

40G, OSIC, SLIC10, and SLIC10 Flex circuit packs 1-65


6500 Packet-Optical Platform 40G, 100G, OSIC, and SLIC10 Circuit Packs
Release 9.3 323-1851-102.4 Standard Issue 3