Вы находитесь на странице: 1из 4

Symbol

# Sta
max
mc

opt

(%)
max

A (SF)
V (CF)
V (CY)
w
# Gal / CF
max * max (%)
W

opt

(lb)

Values
1.00

Units
Sta

Description
Number of Stations to Calculate

132

lb / CF

Proctor Max Dry Density (Test Results)

Proctor Optimum Moisture (Test Results)

100.00%
2.25
225.00
8.33

%
SF
CF / 1 Sta
CY / 1 Sta

Required Compaction as a % of Proctor


Geometric Cross Sectional Area of Base (See P
Volume of Base (CF) Per Calculated # of Sta,
Volume of Base (CY) Per Calculated # of Sta,

62.4
7.480519

lb / CF
gal / CF

Unit Weight of Water


Conversion Factor for Number of Gallons per C

lb / CF

Required Compaction
Wt of Base @ Req'd Compaction @ mc

8.20%

132
32,135.40

lb / 1 Sta

Moisture
Content of
Base
mc i (%)

Weight of
Base Needed
Per 1 Station
W i (lb)

Weight of
Base Needed
Per 1 Station
W i (ton)

Weight of
Water to Add
Per 1 Station
H2O i (lb)

0.0%
1.0%
2.0%
3.0%
4.0%
5.0%
6.0%
7.0%
8.0%
9.0%
10.0%
11.0%
12.0%
13.0%
14.0%
15.0%
16.0%
17.0%
18.0%
19.0%
20.0%
21.0%
22.0%
23.0%
24.0%
25.0%

29,700.0
29,997.0
30,294.0
30,591.0
30,888.0
31,185.0
31,482.0
31,779.0
32,076.0
32,373.0
32,670.0
32,967.0
33,264.0
33,561.0
33,858.0
34,155.0
34,452.0
34,749.0
35,046.0
35,343.0
35,640.0
35,937.0
36,234.0
36,531.0
36,828.0
37,125.0

14.85
15.00
15.15
15.30
15.44
15.59
15.74
15.89
16.04
16.19
16.34
16.48
16.63
16.78
16.93
17.08
17.23
17.37
17.52
17.67
17.82
17.97
18.12
18.27
18.41
18.56

2,435.4
2,138.4
1,841.4
1,544.4
1,247.4
950.4
653.4
356.4
59.4
-237.6
-534.6
-831.6
-1,128.6
-1,425.6
-1,722.6
-2,019.6
-2,316.6
-2,613.6
-2,910.6
-3,207.6
-3,504.6
-3,801.6
-4,098.6
-4,395.6
-4,692.6
-4,989.6

opt

W i (lb) = V (CF) *

max

max

(%) * (1+mc i (%) )

Wi (ton) = Wi (lb) / 2000


H20 i (lb) = W

opt

(lb) - W i (lb)

H20 i (gal) = H20 i (lb) / w* 7.480519 0.11988 * H20 i (lb)


*
*
*
*
*

Notes:
The water to add (to base) is the amount of water needed to add (or dry out) in order to
Negative values (-) indicate that the base needs to dry by the amount shown in order to
The above values are for CSJ 0550-03-024 (FM 914)
2.25 SF (pg 13) is area of base for one side of roadway, so quantities shown are for one s

of Stations to Calculate

ax Dry Density (Test Results)

ptimum Moisture (Test Results)

Compaction as a % of Proctor
c Cross Sectional Area of Base (See Plans)
f Base (CF) Per Calculated # of Sta, A (SF) * 100 (Ft) * # Sta
f Base (CY) Per Calculated # of Sta, V (CF) / 27

ht of Water
on Factor for Number of Gallons per Cubic Foot

Compaction
e @ Req'd Compaction @ mc

opt

max

max

(%) * V (CF)* (1+mc

Volume of
Water to Add
Per 1 Station
H2O i (Gal)
292.0
256.4
220.7
185.1
149.5
113.9
78.3
42.7
7.1
-28.5
-64.1
-99.7
-135.3
-170.9
-206.5
-242.1
-277.7
-313.3
-348.9
-384.5
-420.1
-455.7
-491.3
-526.9
-562.5
-598.2

Legend of Numbers
User Input
Calculated Value
Needed Information

opt

ed to add (or dry out) in order to reach the optimum moisture content
by the amount shown in order to reach the optimum moisture content

so quantities shown are for one side of roadway