Вы находитесь на странице: 1из 1

EPRF-II

Raw Water Requirement

Water usage by refinery Staff


Number of staff per Shift

Requirement per person

Total requirement

Total flow required

Gallons /day

Gallon/day

Gpm

20

3600

30.0

60

Water For Boiler Feed Water


Mode-1

Mode-2

Mode-3

Steam
Required

Recovered

Condensate

Water Required
With condensate
recovery

Water required
without
condensate
recovery

Steam
Required

Condensate

Recovered

Water Required
With condensate
recovery

Water required
without
condensate
recovery

Steam
Required

Condensate

Recovered

Water Required
With condensate
recovery

Water required
without
condensate
recovery

TPH

TPH

GPM

GPM

TPH

TPH

GPM

GPM

TPH

TPH

GPM

GPM

22.04

22.04

39.6

39.6

2.5

11.00

11.00

Normal operating Condition


5.01

Design Condition
Mode-1

Mode-2

Mode-3

Boiler Rating

Steam Required

Boiler Rating

Steam Required

Boiler Rating

Steam Required

TPH

GPM

TPH

GPM

TPH

GPM

22

40

2.5

11

Process Water Requirement


Mode-1

Mode-2

Mode-3

GPM

GPM

GPM

20

68.95

20

Considering all batch preparation simultaneous

Cooling water Makeup


Mode-1

Mode-2

Mode-3

Total flow

Makeup water

Total flow

Makeup water

Total flow

Makeup water

gpm

gpm

gpm

gpm

gpm

gpm

1929

38

2609

57

1728

38

Miscellaneous
Lab Area / Dispensary

Miscellaneous

100

300

Total Quantity Requierd

Total Flow Required

Gallons

gpm

400

1.11

Total Requirement

Flow of water (with 20% margin)

gpm

Quantity of water used

gallon

MI

MII

MIII

111.21

197.1

100.2

119407.36

238423.26

99535.11

Avaialble

Quantity of water available

bbl

Quantity of water available

gallon

Reserve for Days

12092
507864
4.25

2.13

5.10

Вам также может понравиться