Вы находитесь на странице: 1из 6

~IJ.

Republic of the Philippines


DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS

/.,3 ~r?61H

D}. - Ctr ~~/b~

OFFICE OF THE SECRETARY


Manila

25 JAN

2016

DEPARTMENT ORDER

39

NO.
Series of 2016~.

SUBJECT: GUIDELINES ON LOAD POSTING OF

BRIDGES

0</"./4

For the purpose of preventing premature deterioration and damage or preclude any danger of
collapse of bridges along national roads due to truck overloading and as a means of preserving
bridges, the following guidelines are hereby issued for the implementation and compliance of all
concerned:
L The Regional Office concerned shall conduct condition inspection of aU bridges in their
area of responsibility and shall be responsible in the determination of the live load
capacity as well as its posting.
2. Load Rating (load capacitY determination) shall be required for all bridges exhibiting
progressive or advanced stage of deterioration, bridges damaged by calamities and
bridges that have been rated as being in poor or bad condition based on data from the
Bridge Management System as per result of the recent actual inspection conducted by
the Regionalor District Office as deemed necessary.
3. All derated permanent bridges along national roads shall be proVided with the
Informative sign on live load limit for two (2), three (3) and five (5) axle vehicles to be
posted on conspicuous place within 5.0m before the abutment at both approaches.
4. As a guide and to have uniform procedure and parameters in the determination of the
live load limits, the Manual for Load Rating of Bridges (MLRB), 3fd EditIon issued per
0.0.94 Series of 2014 shall be used.
5. For other types of bridges not included in the MLRBUser's Manual, the determination of
the live load capacity shall be done by any appropriate method for reinforced concrete
or steel structures as the case may be but should also conform to the current DPWHand
AASHTOStandard Specifications.
6. The live load limit signs shall be in accordance with the attached standard plan (Annex
"AU) as adopted from the MLRB.

DEPARTMENT ORDER NO.~


Series of 2016
Guidelines on Load Posting of Bridges
Page 2 of 2

7. The Planning Service, this Department shall provide the necessary program and
appropriate funds needed for this purpose.
This Order shall supersede Memorandum Order No.1 dated January 11, 1991, Department
Order No. 66 Series of 2009 and other issuances inconsistent herewith and shall take effect
immediately.

Department of Public Worka and Highways


Office of the Secretary

1111111111111111111111111111111111111

WIN6R01226
5.1.4 WlA/ECM

Annex 'j4"of D. O. NO.~,

ANNEX

s. 2016
Page 1 of 4

"A"

800
50

156

25

338

25

156

50

0
tfl
tfl
N

90

78

80

;::::

0
0

tfl

0
0

156

156
97

~
~

186

~
~

0
t'-

78

71

225

0
0

0
t'-

o
t'-

~
~

0
t'-

;::::
ll)

0
ll)

DETAIL OF SERIES
SCALE

120DN

LETTERS & NUMERICAL


1

DIMENSIONS
5M.

NOTE: THE ACTUAL LOAD RATING SHALL BE BASED FROM THE RESULT OF THE ANALYSIS

Annex ''A''of D. O. No.

1900 to 3650

3'9

, s. 2016
Page 2 of 4

800
SIGN FACES: BLACK
LOAD LIMIT FONT: FRANKLIN GOTHIC MEDiUM
--

LOA

BACKGROUND: WHITE
l7T, 27T, 38T FONT: MS PGOTHIC

LIMIT

ALL SIGN FACE SHALL BE


PROCESSED WITH SUBSTRATE
G.!. PLATE GAUGE No. 16
AND MUST BE REFLECTORIZED
" ENGINEER'S GRADE "

17T
27 T

o
o
N

. 38T

--

FRAME: RED
(RGB: 255, 0, 0)
(CMYK: 0, 99, 100, 0)
SCHEDULE 40
100mm0 G.!. PIPE POST
YELLOW
(RGB: 255, 255, 0)
(CMYK: 6, 0, 97, 0)

300x300x25mm

BASEPLATE

o
L()

4-l6mm0x300mm
ANCHOR BOLTS WITH NUTS
AND WASHERS

G.!.

o
L()

CD

CONCRETE CLASS "A"

o
o
n

ELEVATION

LEAN CONCRETE

o
L()

800

50

50

800
250

300

250
4-16mm0x300mm
G.I. ANCHOR BOLTS WITH NUTS AND WASHERS
100mm<il G.!. PIPE POST

o
L()

PLAN

o
00

o
o
n

SIGNPLATE

o
L!'l
N

3-16mm0
COUNTERSUNK
FLAT HEAD BOLT
wi NUT AND WASHER

DETAilS OF INSTAllATION
SCALE

1 : 20M.

Annex ''A" of D. O. No. .39

, 5.2016

Page 3 of 4
800
SIGN FACES: BLACK
LOAD liMIT FONT: FRANKLIN GOTHIC MEDIUM

LOA

BACKGROUND: WHITE

17T, 27T, 38T FONT: MS PGOTHIC

LIMIT
o
o
N

. 17T
27 T
~38T

ALL SIGN FACE SHALL BE


PROCESSED WITH SUBSTRATE
G.!. PLATE GAUGE No. 16
AND MUST BE REFLECTORIZED
" ENGINEER'S GRADE "
FRAME: RED
(RGB: 255, 0, 0)
(CMYK: 0, 99, 100, 0)
SCHEDULE 40
100mm0 G.!. PIPE POST
YELLOW
(RGB: 255, 255, 0)
(CMYK: 6, 0, 97, 0)

FRONT

VIEW

800

!
BACKGROUND: WHITE

0
0
N

..

750x50x 1Omm FLAT BAR


WELDED AT THE BACK
OF G.!. PLATE

3-16mm0
COUNTERSUNK
FLAT HEAD BOLT
WITH NUT AND WASHER

-SCHEDULE 40
100mm0 G.I. PIPE POST
YELLOW
(RGB: 255, 255, 0)
(CMYK: 6, 0, 97, 0)

REAR VIEW

DETAilS OF INSTAllATION
SCALE

1 : 20M.

Annex ';4" of D. O. No.

fJCI

. s. 2016
Page 4 of 4

300X300X25mm

BASE PLATE

4-16mm0x300mm

o
.. ""

G.!. ANCHOR BOLTS WITH


NUTS AND WASHERS
GROUND LINE

1:-/,1/,-(
8-12mm<il

VERTICAL BARS
10mm<il @ 100

LATERAL TIES
16mm<il @ 175

BOTHWAYS
o
o
n

LEAN CONCRETE

o
L()

ELEVATION
800
250

300

250

16mm<il @ 175

L()

BOTHWAYS
8-12mm<il

<Xl

~v

0
0

VERTICAL BA.RS

~
0

0
L()

10mm<il @ 100

LATERAL TIES

PLAN
DETAILS
SCALE

OF PEDESTAL
1 : 15M.

Вам также может понравиться