/.,3 ~r?61H
25 JAN
2016
DEPARTMENT ORDER
39
NO.
Series of 2016~.
BRIDGES
0</"./4
For the purpose of preventing premature deterioration and damage or preclude any danger of
collapse of bridges along national roads due to truck overloading and as a means of preserving
bridges, the following guidelines are hereby issued for the implementation and compliance of all
concerned:
L The Regional Office concerned shall conduct condition inspection of aU bridges in their
area of responsibility and shall be responsible in the determination of the live load
capacity as well as its posting.
2. Load Rating (load capacitY determination) shall be required for all bridges exhibiting
progressive or advanced stage of deterioration, bridges damaged by calamities and
bridges that have been rated as being in poor or bad condition based on data from the
Bridge Management System as per result of the recent actual inspection conducted by
the Regionalor District Office as deemed necessary.
3. All derated permanent bridges along national roads shall be proVided with the
Informative sign on live load limit for two (2), three (3) and five (5) axle vehicles to be
posted on conspicuous place within 5.0m before the abutment at both approaches.
4. As a guide and to have uniform procedure and parameters in the determination of the
live load limits, the Manual for Load Rating of Bridges (MLRB), 3fd EditIon issued per
0.0.94 Series of 2014 shall be used.
5. For other types of bridges not included in the MLRBUser's Manual, the determination of
the live load capacity shall be done by any appropriate method for reinforced concrete
or steel structures as the case may be but should also conform to the current DPWHand
AASHTOStandard Specifications.
6. The live load limit signs shall be in accordance with the attached standard plan (Annex
"AU) as adopted from the MLRB.
7. The Planning Service, this Department shall provide the necessary program and
appropriate funds needed for this purpose.
This Order shall supersede Memorandum Order No.1 dated January 11, 1991, Department
Order No. 66 Series of 2009 and other issuances inconsistent herewith and shall take effect
immediately.
1111111111111111111111111111111111111
WIN6R01226
5.1.4 WlA/ECM
ANNEX
s. 2016
Page 1 of 4
"A"
800
50
156
25
338
25
156
50
0
tfl
tfl
N
90
78
80
;::::
0
0
tfl
0
0
156
156
97
~
~
186
~
~
0
t'-
78
71
225
0
0
0
t'-
o
t'-
~
~
0
t'-
;::::
ll)
0
ll)
DETAIL OF SERIES
SCALE
120DN
DIMENSIONS
5M.
NOTE: THE ACTUAL LOAD RATING SHALL BE BASED FROM THE RESULT OF THE ANALYSIS
1900 to 3650
3'9
, s. 2016
Page 2 of 4
800
SIGN FACES: BLACK
LOAD LIMIT FONT: FRANKLIN GOTHIC MEDiUM
--
LOA
BACKGROUND: WHITE
l7T, 27T, 38T FONT: MS PGOTHIC
LIMIT
17T
27 T
o
o
N
. 38T
--
FRAME: RED
(RGB: 255, 0, 0)
(CMYK: 0, 99, 100, 0)
SCHEDULE 40
100mm0 G.!. PIPE POST
YELLOW
(RGB: 255, 255, 0)
(CMYK: 6, 0, 97, 0)
300x300x25mm
BASEPLATE
o
L()
4-l6mm0x300mm
ANCHOR BOLTS WITH NUTS
AND WASHERS
G.!.
o
L()
CD
o
o
n
ELEVATION
LEAN CONCRETE
o
L()
800
50
50
800
250
300
250
4-16mm0x300mm
G.I. ANCHOR BOLTS WITH NUTS AND WASHERS
100mm<il G.!. PIPE POST
o
L()
PLAN
o
00
o
o
n
SIGNPLATE
o
L!'l
N
3-16mm0
COUNTERSUNK
FLAT HEAD BOLT
wi NUT AND WASHER
DETAilS OF INSTAllATION
SCALE
1 : 20M.
, 5.2016
Page 3 of 4
800
SIGN FACES: BLACK
LOAD liMIT FONT: FRANKLIN GOTHIC MEDIUM
LOA
BACKGROUND: WHITE
LIMIT
o
o
N
. 17T
27 T
~38T
FRONT
VIEW
800
!
BACKGROUND: WHITE
0
0
N
..
3-16mm0
COUNTERSUNK
FLAT HEAD BOLT
WITH NUT AND WASHER
-SCHEDULE 40
100mm0 G.I. PIPE POST
YELLOW
(RGB: 255, 255, 0)
(CMYK: 6, 0, 97, 0)
REAR VIEW
DETAilS OF INSTAllATION
SCALE
1 : 20M.
fJCI
. s. 2016
Page 4 of 4
300X300X25mm
BASE PLATE
4-16mm0x300mm
o
.. ""
1:-/,1/,-(
8-12mm<il
VERTICAL BARS
10mm<il @ 100
LATERAL TIES
16mm<il @ 175
BOTHWAYS
o
o
n
LEAN CONCRETE
o
L()
ELEVATION
800
250
300
250
16mm<il @ 175
L()
BOTHWAYS
8-12mm<il
<Xl
~v
0
0
VERTICAL BA.RS
~
0
0
L()
10mm<il @ 100
LATERAL TIES
PLAN
DETAILS
SCALE
OF PEDESTAL
1 : 15M.