Вы находитесь на странице: 1из 4

PURCHASE DIVISION

DEPARTMENT QUALITY MANUAL


Revision No.

02

Dt of Revision

: 17.9.2012

Issue No

: 2

Issue Dt. : 30.06.2003


Page No.
Issued by

Section

: 0

Topic

: FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS)

: 1 OF 3

QA
Document

DQM-01

FORMAT NO.:PUR/TENDDOC/P6/06
CPRI
www.tenderwizard.com/CPRI
Section II -Technical Specification
Tender Enquery No : BUY/DSD-01/16-17
Name of the Equipment: Power Quality Analyzer, Software & other accessories
Note :The Offers should be submitted only in this format otherwise the offer will be liable for rejection
A detailed technical catalogue/literature/phamplet and any other technical details shall be sent in hard copy in a sealed cover superscribing enquiry number
and due date so as to reach the following address with the due date and time. This is very much essential to evaluate your offer.
Name of the Vendor
Offer Number and Date
Sl.No.

Parameters

CPRI Specification/Requirements

Qty

To be completed by the Bidder


Guaranteed
Technical
Particulars
(GTP)

Place where equipment to be supplied

Distribution Systems Division, CPRI, Bangalore

Scope (supply / supply & Installation / Supply of Power Quality Analyzer, Software & other accessories
suply, installation & training)

Measurement type

Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or


Three-phase 4-wire plus one extra input channel (must be
synchronized to reference channel during AC/DC measurement)

Display

6.5 TFT color LCD 16 bit resolution (min.)

RMS AC Voltage range

0 to 780 V rms
Page 1 of 4

Deviation/Remark
s Specify if any

DC voltage range

0 to 780 V

Harmonic voltage

upto 50th order

Harmonic voltage phase angle

upto 50th order

Voltage flicker

Both Pst & Plt

10

Voltage unbalance factor

As IEC or IEEE standard

11

High-order harmonic component

2 kHz to 80 kHz

12

Transient over voltage

2 MHz sampling (min.)

13

Transient measurement (min.)

6.0 kV peak

14

Inter harmonic (voltage/ current)

0.5 Hz to 49.5 Hz

15

Voltage Accuracy

0.1% of nominal voltage or less

16

RMS Current range

AC/DC upto 2000 Amps

17

Current harmonics

upto 50th order

18

Harmonic current phase angle

upto 50th order

19

Current unbalance

Current unbalance

20

Current Accuracy

0.2 % rdg. 0.1 % f.s. + current sensor accuracy or less

21

Power accuracy

0.2 % rdg. 0.1 % f.s. + current sensor accuracy or less

22

Harmonic power

upto 50th order

23

Harmonic voltage-current phase angle upto 50th order

24

Frequency range

40 to 70 Hz or wider range

25

Voltage channels

4 Nos.

26

Current Channels

4 Nos.

27

Input resistance

Voltage: 3.92 4.08 M; Current: 90 110 k


Page 2 of 4

28

Time plot recording (min.)

Time plot interval setting for (max/min/average) reading at interval


of 1s, 15s, 30s, 1min., 5min., 15min., 30min., 1h, 2h, etc. or better
features

29

Screen shot recording

OFF, 5min., 10min., 30 min., 1h, 2h, etc., or better features. The
recording can be done with internal memory or external memory like
SD card

30

Start and end recording

Either manual recording or automatic setting

31

Power supply

AC Adapter for power supply voltage range of 100 V AC to 240 V AC,


50 Hz

32

Battery Pack

Battery pack of Ni-MH 7.2 V DC 4500 mAh (min.) or better version


and provide minimum 3 h hours back up with battery supply.

33

Data transfer

USB port or LAN

34

Memory capacity

32 GB with SD card (min.)

35

Data Conversion

Data can be converted easily into CSV format.

36

Operating temperature and humidity

0 50 oC and 80 % RH

Page 3 of 4

37

Accessories

Instruction manual 1 No., Voltage Cords - 1 set


(Red/Yellow/Blue/Gray, each 1, Black 4, Alligator clip 8), AC
Adapter 1 No., Strap No., USB cable (1 m length min.) 1 No.,
Battery Pack 1 No., SD memory card 32 GB 1 No.

38

Carry case

1 No.

39

Current probes / clamps

a) AC/DC clamps upto 100 A 4 Nos.


b) AC/DC clamps upto 2000 A 4 Nos.

40

Calibration certificate

Calibration certificate for power quality analyzer and current clamps


from any NABL accredited laboratory in India or NIST laboratory

Note : Compliance to meeting all of the above technical specification requirement should be furnished in detail against each serial number in GTP column with
supporting technical write up, illustrations, schematics, single line diagrams, drawings, catalogues of proposed sub-equipment & instruments suppliers etc.
PN : 1. A detailed technical catalogue/literature/phamplet and any other technical details shall be sent in hard copy in a sealed cover super scribing tender
enquiry number and due date so as to reach the following address within the due date and time. This is very much essential to evaluate your offer.
2. Letter of authorization issued by the foreign Principal shall also be sent by the Indian agents who have offered on behalf of their Principals.
The Joint Director (Purchase)
Central Power Research Institute,
Post Box No.8066
Prof.Sir C.V.Raman Road, Sadashivanagar Post Office,
BANGALORE-560 080. INDIA
Ph. No.080-23602919 / 23602829
Fax : 080-23604446

Page 4 of 4