Вы находитесь на странице: 1из 11

UMG8900 Hardware

Introduction
HUAWEI
TELECOMMUNICATION PVT.
LIMITED

Cabinet UMG8900 adopts N68E

Power Distribution Box

SSM-256 or SSM-32
Frame
Fan Box
Boards

UMG Specification
E1 Capacity 10 k Erl
Rated input voltageC48 V/C60 V
Power consumption (single frame)1100 W
at most (much less than this value when
no resource board is available)
Maximum input currentsTwo C48
V/C60 V inputs in the hot backup mode:
100 A per input

Mechanical Specification
Cabinet dimensions (height width depth) 2200 mm
600 mm 800 mm
Frame dimensions (height width depth)533.4 mm
482.6 mm 500 mm Cabinet weight
N68-22 rack: about 95 kg [209 lb]; fully configured N6822 cabinet: about 330 kg [728 lb], including the cabinet
doors, three fully configured service frames, ];
Bearing capacity> 600 kg/m2 [0.85 lbf/in.2]

OMU Board
MOMU

MOMB

System management board of main control


frame(SSM256). Provide BAM function. Inserted in slot
7, 8 and work in 1+1 backup. Providing FE switching
for internal control and signaling traffic.

System management board of main control


frame(SSM32). Provide BAM function. Inserted in slot
6/7, 8/9 and work in 1+1 backup. Providing GE
switching for IP voice traffic.

MMPB

Configured in SSM32 Slot 6/7, 8/9. Providing GE


switching for IP voice traffic. Work in1+1 backup.
System management function is implemented by
MTNC. Only packet service is required, the MMPB is
configured.

MHRD

MHRD is a back board, which equals the combination of


HRU + G1O or HRU + E8T.
D8FT subboard is inserted in the UG01MHRD1, which
provides eight fast Ethernet (FE) interfaces.
D1GO subboard is inserted in the UG01MHRD2, which
provides one gigabit Ethernet (GE) interface.
The ports on the UG02MHRD can work in load-sharing or
master/slave mode.

MNET

Provide GE switching function in SSM256 frame


UG02MNET provides 2*GE and 4*FE cascading interfaces

Receive clock signal from CLK and distribute the clock


signal to TDM processing boards within the frame
Work in 1+1 backup mode

MTNB

MTNB configured in SSM256 frame


Providing 256k TDM switching function
Provide 4*8k TDM cascading connecting
Support 1+1 backup work mode
MTNB is inserted in back plane slot 6 & 9

MSPF

Implementing the core function of the signaling gateway by


supporting the M3UA//M2UA/V5UA/IUA adaptation on
signaling, and forwarding adapted messages to the media
gateway controller (MGC).
Receiving signaling from TDM switching units through the
Subboard (SHPU), and processing the TDM signaling.

MVPD

The MVPD enables the following functions:


- Supporting functions such as announcement playing, digit
collecting, audio mixing and MFC.
- Implementing IP packet adaptation of voice services based
on UDP, RTP and IP.

MTNC is configured in SSM32 frame

MTNC
MTNC provides device management function (MPU function)
UG01MTNC can support 32k TDM switching function
UG02MTNC can support 96k TDM switching function
MTNC supports FE switching function for control plane and internal
signaling traffic.
MTNC provides clock function through CKMB sub-board
MTNC can receive 16 KHz stratum-2 clock from CLK and deliver 8 KHz
clock through the TDM cascading path between frames

MCLK

MCLKs are inserted in back slots 0 and 1 in the main


control frame and work in 1+1 standby mode.

The MCLK can be inserted in both SSM-256 frames and


SSM-32 frames.
MCLK can generate stratum two clock signal

ME32

They can be inserted in both SSM-256 frames


and SSM-32
The ME32 enables the following functions:
- Providing 32 E1 interfaces.
- Providing 32 E1 frames.
- Providing the function of drawing the line
signaling of the R2 signaling or inserting the
signaling
Echo canceller unit.

ECU
It is a front board used for ECHO canceling.

END OF UMG INTRODUCTION